1200 Standard Load Cell (U.S. & Metric) : The Leader in Force Measurement

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

The Leader in Force Measurement

1200 Standard Load Cell


(U.S. & Metric)
Proprietary Interface temperature
compensated strain gages
Performance to .04%
High output to 4 mV/V
Eccentric load compensated
.0008%/F (.0015%/C) temp. effect on output
Low deflection
Shunt calibration
Barometric compensation
Tension and compression
Compact size

DIMENSIONS
1210
See
Drawing
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)

1200
10/18/13

(9)
(10)
(11)
(12)
(13)

U.S. (lbf)
300, 500, 1K,
2K, 5K, 10K,
inch
4.13
1.38
1.25
1.34
3.50
22.5
0.28
8 places
5/8-18 UNF-3B
1.12 deep
0.20
1.13
0.03
1.25
5/8-18 UNF-3B
.87 deep

Metric (kN)
1.5, 2.5, 5
10, 25, 50
mm
104.8
34.9
31.7
34.0
88.9
22.5
7.10
M16 x 2-4H
28.4 deep
5.10
28.6
0.80
31.8
M16 x 2-4H
22.1 deep

MODEL
1220
CAPACITY
U.S. (lbf)
Metric (kN)

1232
U.S. (lbf)

Metric (kN)

25K, 50K

100, 250

100K

450

inch
6.06
1.75
1.63
2.65
5.13
15.0
0.41

mm
153.9
44.5
41.4
67.3
130.3
15.0
10.4

inch
8.00
2.50
2.25
3.76
6.50
11.25
0.53

mm
203.2
63.5
57.2
95.2
165.1
11.25
13.5

12 places
1 1/4-12 UNF-3B
M33 x 2-4H
1.40 deep
35.6 deep
0.30
7.60
1.75
44.5
0.03
0.80
2.25
57.2
1 1/4-12 UNF-3B
M33 x 2-4H
1.40 deep
35.6 deep

16 places
1 3/4-12 UN-3B
2.15 deep
0.40
2.00
0.03
3.00
1 3/4-12 UNF-3B
1.75 deep

M42 x 2-4H
54.6 deep
10.2
50.8
0.80
76.2
M42 x 2-4H
44.5 deep

Interface Inc. 7401 East Butherus Drive Scottsdale, Arizona 85260 USA Phone: 480.948.5555 Fax: 480.948.1924
www.interfaceforce.com Email: [email protected] ORDER TOLL-FREE 800.947.5598

The Leader in Force Measurement


SPECIFICATIONS
MODEL

PARAMETERS

1210

1210

1220

1232

U.S. Models (lbf)


Metric Models (kN)
ACCURACY (MAX ERROR)
Static Error Band% FS
Nonlinearity% FS
Hysteresis% FS
Nonrepeatability% RO
Creep, in 20 min%
Side Load Sensitivity%
Eccentric Load Sensitivity%/in
TEMPERATURE
Compensated RangeF
Compensated RangeC
Operating RangeF
Operating RangeC
Effect on Zero%RO/F MAX
Effect on Zero%RO/C MAX
Effect on Output%RO/F MAX
Effect on Output%RO/C MAX
ELECTRICAL
Rated OutputmV/V (Nominal)
Excitation VoltageVDC MAX
Bridge ResistanceOhm (Nominal)
Zero Balance% RO
Insulation ResistanceMegohm
MECHANICAL
Safe Overload% CAP
Deflection @ ROinch
Deflection @ ROmm
Optional BaseP/N (Metric)
Natural FrequencykHz
Weightlb
Weightkg
Connector
Calibration

300, 500, 1K, 2K


1.5, 2.5, 5, 10

5K, 10K
25, 50

25K, 50K
100, 250

100K
450

0.04
0.04
0.03
0.01
0.025
0.25
0.25

0.04
0.04
0.04
0.01
0.025
0.25
0.25

0.04
0.04
0.05
0.01
0.025
0.25
0.25

0.06
0.05
0.06
0.01
0.025
0.25
0.25

15 to 115
-10 to 45
-65 to 200
-55 to 90
0.0008
0.0015
0.0008
0.0015

15 to 115
-10 to 45
-65 to 200
-55 to 90
0.0008
0.0015
0.0008
0.0015

15 to 115
-10 to 45
-65 to 200
-55 to 90
0.0008
0.0015
0.0008
0.0015

15 to 115
-10 to 45
-65 to 200
-55 to 90
0.0008
0.0015
0.0008
0.0015

2.0
20
350
1.0
5000

4.0
20
350
1.0
5000

4.0
20
350
1.0
5000

4.0
20
350
1.0
5000

150
0.001
0.03
B101 (M)
3.9, 5.0, 6.9, 9.8
1.5
0.7
PC04E-10-6P
T&C

150
0.002
0.05
B102 (M)
6.6, 9.4
3.3
1.5
PC04E-10-6P
T&C

150
0.002
0.05
B103 (M)
6.5, 7.0
9.5
4.3
PC04E-10-6P
T&C

150
0.003
0.08
B112 (M)
5.8
26
11.8
PC04E-10-6P
T&C

OPTIONS
Base (recommended)
Compression Overload Protection
Integral 10 ft Cable
Bayonet Connector
Multiple Bridge
Standardized Output
Connector Protection
Transducer Electronic Data Sheets (TEDS)

CAPACITY

STANDARD CONFIGURATIONS
10 ft Integral Cable (12xxAJ-nn)
<or> PC04E-10-6P Standard Connector (12xxAF-nn)
<or> PC02E-10-6P Bayonet Connector (12xxACK-nn)
Installed Base (-B suffix)

ACCESSORIES
Mating Connector
Instrumentation
Loading Hardware
Shown with optional base

Interface Inc. 7401 East Butherus Drive Scottsdale, Arizona 85260 USA Phone: 480.948.5555 Fax: 480.948.1924
www.interfaceforce.com Email: [email protected] ORDER TOLL-FREE 800.947.5598