Current Transformers
Introduction
Trench is a recognized world leader in the
design and manufacture of high voltage
equipment for application on electric
utility and high energy industrial systems.
As part of Trench's product scope, the
Company produces a diversified range of
Instrument Transformers which are installed on 69 - 800kV electrical
systems. Instrument Transformers
include: Voltage (Potential)
Transformers (both inductive and
capacitive type), Current Transformers and Combined Instrument
Transformers (voltage and current
transformer in one unit).
Current Transformers must convert high transmission line currents
(up to 5000 A) to standardized
low and easily measurable values,
which will be used for metering,
protection and control of the high
voltage system. As such, the need
for accurate and reliable current
transformation is essential.
Fig. 1
Type IH-650,
high accuracy
current transformer
Features
Fig. 2
Sectioned
view of a
typical IK5
current
Transformer
Construction
Standard Equipment
Catalog Numbering
System
Series
IK5
IK5-650-202 S
Current Transformer Selection
Series
IK5
IM
IH
150
200
250
350
550
650
750
900
1050
IK5-150IK5-200IK5-250IK5-350IK5-550IK5-650IK5-750IK5-900IK5-1050-
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
350
550
650
750
900
1050
IM-350IM-550IM-650IM-750IM-900IM-1050-
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
150
200
250
350
550
650
750
900
1050
IH-150IH-200IH-250IH-350IH-550IH-650IH-750IH-900IH-1050-
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.1)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
(No.2)
Primary
Nominal Suffix
Amperes No. 1
50
100
150
200
300
400
600
800
1000
1200
1500
1600
2000
3000
50
100
150
200
300
400
600
100
150
200
300
400
600
800
1000
1200
1500
1600
2000
3000
500
101
151
201
301
401
601
801
102
122
152
162
202
302
500
101
151
201
301
401
601
101
151
201
301
401
601
801
102
122
152
162
202
302
50:5
100:5
150:5
200:5
300:5
400:5
600:5 600:5MR
800:5
1000:5
1200:5 1200:5MR
1500:5
1600:5
2000:5 2000:5MR
3000:5 3000:5MR
50:5
100:5
150:5
200:5
300:5
400:5
600:5 600:5MR
100:5
150:5
200:5
300:5
400:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
3000:5
-
Consult
Factory
Consult
Factory
50X100:5
75X150:5
100X200:5
150X300:5
200X400:5
300X600:5
400X800:5
500X1000:5
600X1200:5
750X1500:5
800X1600:5
1000X2000:5
1500X3000:5
Accuracy Selection
Series
IK5
IM
IH1)
Metering Accuracy
% of Nameplate Rating
Optional
100%
10%
5%
1%
Not
Not
0.3%
0.6% specified
specified
0.3%
0.6%
by ANSI
by ANSI
0.15% 2) 0.15% 2) 0.15%2)
0.3%4)
Burden
Rating Class
Relay Accuracy
Relay
Class
BO.1-1.8
C200 3
BO.1-1.8
BO.1-1.8
Electrical Characteristics
Series
BIL
Applied Creepage
(kV) Withstand Distance
(kV)
IK5
IM
IH
in/mm
Strike
Distance
in/mm
150
200
250
350
550
650
750
900
1050
50
70
95
140
230
275
325
395
460
34/864
34/864
52/1321
52/1321
92/2337
112/2845
169/4293
169/4293
214/5436
13/330
13/330
24/610
24/610
40/1016
48/1219
65/1651
65/1651
84/2134
350
550
650
750
900
1050
140
230
275
325
395
460
52/1321
101/2565
131/3327
169/4293
169/4293
214/5436
24/610
42/1067
54/1372
65/1651
65/1651
84/2134
150
200
250
350
550
650
750
900
1050
50
70
95
140
230
275
325
395
460
34/864
34/864
52/1321
52/1321
101/2565
131/3327
169/4293
169/4293
214/5436
13/330
13/330
24/610
24/610
42/1067
54/1372
65/1651
65/1651
84/2134
For units rated C400 or C800 relay class rating consult factory
Note: Consult factory for ratios not listed.
Ratio
25/50:5
50/100:5
75/150:5
100/200:5
150/3005
200/400:5
300/600:5
400/800:5
500/1000:5
600/1200:5
750/1500:5
800/1600:5
1000/2000:5
1500/3000:5
25/50:5
50/100:5
75/150:5
100/200:5
150/300:5
200/400:5
300/600:5
100:5
150:5
200:5
300:5
400:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
3000:5
Thermal
Rating
Factor
at 30 C
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.5
2.0/1.0
2.0/2.0
2.0/2.0
2.0/2.0
2.0/2.0
2.0/2.0
2.0/2.0
2.0/2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.875
1.5
1.0
Mechanical
Short-Time
Current
Thermal Current
Rating
Rating
kA RMS Max. (1 sec.) kA RMS
4
8
12
15
24
30
60
60
60
120
120
120
120
120
21
31
49
63
63
63
63
8
12
15
24
30
30
60
60
60
120
120
120
120
3
6
10
13
20
26
39
52
60
90
90
90
90
90
21
31
49
63
63
63
63
6
10
10
20
25
25
50
50
50
90
90
90
90
Dimensional Table
Type
Series BIL (kV)
IK5-150
150
50.26
(1277)
IK5-200 200 50.26
(1277)
IK5-250 250 61.13
(1553)
IK5-350 350 61.13
(1553)
IK5-550 550 80.38
(2042)
IK5-650 650 88.45
(2247)
IK5-750 750 120.13
(3051)
IK5-900 900 120.13
(3051)
IK5-1050 1050 138.50
(3518)
39.19
(995)
39.19
(995)
50.06
(1272)
50.06
(1272)
69.12
(1755)
77.19
(1961)
100.62
(2556)
100.62
(2556)
119.00
(3023)
13.40
(340)
13.40
(340)
24.21
(615)
24.21
(615)
40.27
(1023)
48.34
(1228)
65.28
(1658)
65.28
(1658)
83.65
(2125)
10.50
(267)
10.50
(267)
10.50
(267)
10.50
(267)
11.00
(279)
11.00
(279)
14.00
(356)
14.00
(356)
14.00
(356)
Dimensions (in./mm) 1
E
F
G
14.00
(356)
14.00
(356)
14.00
(356)
14.00
(356)
14.00
(356)
14.00
(356)
21.00
(533)
21.00
(533)
21.00
(533)
13.94
(354)
13.94
(354)
13.94
(354)
13.94
(354)
13.94
(354)
13.94
(354)
20.58
(523)
20.58
(523)
20.97
(533)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
24.00
(610)
24.00
(610)
24.00
(610)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
17.00
(432)
24.00
(610)
24.00
(610)
24.00
(610)
23.75
(603)
23.75
(603)
23.75
(603)
23.75
(603)
28.00
(711)
28.00
(711)
31.75
(806)
31.75
(806)
31.75
(806)
17.25
(438)
17.25
(438)
17.25
(438)
17.25
(438)
22.25
(565)
22.25
(565)
25.25
(565)
25.25
(565)
25.25
(565)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
4.50
(114)
295
(134)
295
(134)
335
(152)
335
(152)
600
(272)
640
(291)
1640
(745)
1640
(745)
1800
(817)
11
(42)
11
(42)
14
(53)
14
(53)
29
(110)
30
(114)
79
(299)
79
(299)
87
(329)
1 Weights and dimensions are approximations only and are not intended for construction purposes.
Note: Dimensions for Series IH and IM differ from that listed for the IK5. Please contact factory for specific details.
Trench Facilities
Trench Limited
Instrument Transformer Division
390 Midwest Road
Scarborough, Ontario
Canada M1P 3B5
Phone: 416-751-8570
Fax: 416-751-6952
Trench Limited
Power Line Carrier Division
815 Middlefield Road, Unit 6A
Scarborough, Ontario
Canada M1V 2P9
Phone: 416-291-8544
Fax: 416-291-5581
Trench China
MWB (Shanghai) Co., Ltd.
No. 3658, Jiancheng Road
Minhang, Shanghai
Peoples Republic of China
200245
Phone: 86-21-54720088
Fax: 86-21-54723118
www.trenchgroup.com
E 217.31
Subject to change without notice (05.2006)
Printed in Canada.