The document provides specifications for an x-ray baggage inspection system (BIS). Some key requirements include a tunnel size of 60cm wide by 40cm high, a conveyor belt speed between 0.18-0.3m/s, an x-ray voltage of 140kV or more, and the ability to detect a 40-36AWG copper wire. The system must also meet health and safety standards for radiation levels and have a resolution of at least 1280x1024 pixels.

Uploaded by

anupamkhanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
751 views3 pages

Technical Specifications of SPP Tech Spec Xbis

The document provides specifications for an x-ray baggage inspection system (BIS). Some key requirements include a tunnel size of 60cm wide by 40cm high, a conveyor belt speed between 0.18-0.3m/s, an x-ray voltage of 140kV or more, and the ability to detect a 40-36AWG copper wire. The system must also meet health and safety standards for radiation levels and have a resolution of at least 1280x1024 pixels.

Uploaded by

anupamkhanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Page 1 of 3

Annexure I

S. No. X-RAY BIS (SMALL SIZE)
1. Tunnel Size 60 cm W (width) x 40 cm H (Height) +/- 10%
2. Conveyor belt speed should be between 0.18 and 0.3 meter per second. Conveyor movement
bidirectional.
3. All machines should operate on 230 VAC, 50 Hz power supply and should be able to withstand
voltage fluctuations in the range of 170 V to 260 V. Single Phase, 3 to 5 Amp.
4. Conveyor Capacity 100 kg or more.
5. Sensors > 1000 diodes, L-shaped detector (Folded array type), In case of defective diode arrays,
scanning should be disabled and error message should be displayed on the screen.
6. X-Ray Voltage 140 KV or more.
7. X-Ray Source/Generator It should be capable to operate smoothly for a period of at least six
years.
8. Duty Cycle 100%
9. Cooling Sealed oil bath
10. The X-ray beam divergence should be such that the complete image at maximum size of bag is
displayed without corner cuts.
11. The radiation level should not exceed accepted health standard (0.1m R/Hr at a distance of 5
CM from external housing). Relevant certificate from AERB.
12. The operating temperature normally should be 10
0
C to 50
0
C
13. Storage temperature 20


0
C to 50
0
C
14. Humidity 90 % non-condensing.
15. Resolution: The machine should be able to display single un- insulated tinned copper wire of 40-
SWG or 36 AWG. All penetration and resolution condition should be met without pressing any
functional key and should be online.
16. Penetration should be 26 mm thickness of steel (Guaranteed) or more.
17. Continuous Electronic Zoom facility should be available to magnify the chosen area of an image
eight times (8X) or more. Image features shall be keyboard controllable.
18. Video display 17 or better LCD Monitor SVGA High resolution, low radiation, flicker free,
resolution at least 1280 x 1024, 24 bit colour real time processing.
19. The machine should have features of Multi-energy X-ray imaging facility where materials of
different atomic number will be displayed in different colours to distinguish high density
organic materials including explosives. Machine should have viable colour or materials stripping
to facilitate the operator to monitor images of organic materials for closer scrutiny. All
suspicious items (Explosives, High density, material narcotics) should be displayed in one mode
and that should be online.
20. Radiation Safety
The machine must comply with requirements of health and safety regulations with regard to
mechanical electrical and radiation hazards. Before installation of the machine, the supplier/
manufacturer should furnish relevant certificate from Atomic Energy Regulatory Board of India
regarding radiation safety. The company manufacturing the equipment should have ISO
certification for manufacturing and servicing of X-ray Screening machines.
21. Film Safety Guaranteed safety for high-speed films up to ISO 1600. The machines should be
film safe. In order words photographic films must not be damaged due to x-ray examination.
22. Machine should be rodent protected. Dust proof cover is to be provided for covering when
system is not in use.
Page 2 of 3


23. Facility for variable contrast must be incorporated to allow enhancement of lighter and darker
portion of the image.
24. The machine should be so designed that software enhancement can be easily implemented to
take care of new technique in image processing and pattern recognition.
25. Through put should be 200 bags per hour or more.
26. Full diagnostic built in test facility. All models should have software controlled diagnosis report
facility and system should give printout if printer is connected.
27. All software features of machine should be online and password protected.
28. Machine should be capable for recalling 15 or more previous images.
29. It should have the capability of archiving 3000 or 4000 images with date & time stamp.
30. Control desk with security housing and locking provision should be available. The operator
personal identification number can be entered the keyboard along with generation of log.
31. Facility of image enhancement should be available.
32. All models should have online recording facility and images can be recorded in CD R/W.
33. Lead impregnated safety screens should be available at either ends of the tunnel. This should be
covered by relevant AERB certificate. Idle rollers to be provided at either ends of the tunnel to
facilitate placing of baggage at input and output.
34. System should work on one software only. All software features should be controlled from key
board of machine only. Keyboard function should be user friendly. To enable/disable the
software features system should not be rebooted.
35. If the machine fails to penetrate a particular item then an alarm video and audio both should be
generated to notify the operator.
36. The threat image projection (TIP) system software to be incorporated in all X-Ray BIS operation
as per details given in Annexure I.
37. Copy of all software including X-Ray Software with recovery CD must be provided.
38. Operational Training Operating staff has to be provided free training.
39. Operating & service manual shall be provided with each machine.
40. Other Features
a. Edge & variable edge enhancement.
b. Inverse video
c. Set up time not more than 10 minutes.
d. Pseudo colour
e. Date & Time display.
41. Minimum Computer Configuration: Intel V Pro Configuration

1. CPU : Intel Core 2 Duo 6300, 1.86 GHz, 2MB L2 cache and
1066 MHz FSB.
2. Mother boards : Intel Q 965/Nvidia chip set, 7025 or better on OEM
Mother board.
3. Bus Architecture : Integrated Graphics, 2 PCI, 1 PCI Express x 1 and 1 PCI
Bxpress x 16.
4. Memory : 2x512 MB 533 MHz DDR2 RAM with minimum 4 total
DIMM slots
5. Hard Disk Drive : 160 GB 7200 rpm serial ATA HDD.
6. Mouse : Optical.
7. Bays : 4 Nos. ( 2 Nos. 5.25 inches for Optical Media Drives and
2 Nos. 3.5 inches for Hard Disk Drives.)
8. Ports : 6 USB Ports (with at least 2 in Front), 1 Serial Port, 1
Parallel port, 1 PS/2 Keyboard and 1 PS2 Mouse Port,
Page 3 of 3

audio ports for microphone and headphone in front.
9. Cabinet : Mini tower.
10. DMA : DMA 2.0 compliance and support.
11. CD-R/ RW Drive : CD Writer.
12. Networking facility : 10/100/1000 on board integrated Network Port with
remote booting facility remote system installation, remote
wakeup, out of band management using any standard
management software.
13. Operating system : Windows Vista Business Or Linux (REDHATELS or
FEDORA8 or any other latest version) preloaded with
Media and Documentation and Certificate of Authenticity.
14. OS Certifications : Win Logo Vista Business OS or Linux Certifications.
15. Power Management : Screen Blanking, Hard Disk and System Idle Mode in
Poser on, Set up Password, Power supply SMPS Surge
protected.
16. Preloaded Software : Norton, McA fee, ETrust or equivalent Antivirus (Latest
Version) with one year License.
42. UPS: 2KVA online with back-up time of hour.