100% found this document useful (1 vote)
2K views1 page

Lumen Method Calculation Worksheet

This document provides a worksheet to calculate the number of light fixtures required for a room based on its dimensions, surface reflectance values, and other factors. It outlines collecting project and room data, determining the room cavity ratio and coefficient of utilization, accounting for various light loss factors, and performing calculations to find the target number of fixtures needed.

Uploaded by

Donald Gabriel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views1 page

Lumen Method Calculation Worksheet

This document provides a worksheet to calculate the number of light fixtures required for a room based on its dimensions, surface reflectance values, and other factors. It outlines collecting project and room data, determining the room cavity ratio and coefficient of utilization, accounting for various light loss factors, and performing calculations to find the target number of fixtures needed.

Uploaded by

Donald Gabriel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Lumen Method Calculation Worksheet

Project Information


Project Name: Type of Activity:
Target Illumination Value:
Fixture Type: # Lamps/Fixture
Lamp Type: Initial Lamp Lumens:


Room Data


Ceiling Reflectance (cc): . Length x Width = Area
Wall Reflectance(wc): .
Floor Reflectance(fc): .
_____ x ______ = ________



Room Cavity Ratio (RCR)


Ceiling Height - Work Surface = Cavity Height 5 x Cavity Height x (Length + Width)
Area
= RCR

_________ - _________ = ____________
5 x ________ x (_____ = _____)
= ______
___________


With RCR, Calculate the Coefficient of Utilization (CU)


Low RCR: CU1:
C
CU1 - CU2 = Y
Actual RCR: Actual CU: ____ - _____ = _____
High RCR: CU2:

C
Actual RCR - Low RCR
High RCR - Low RCR
= _____ = X

C
CU1 - ( X x Y) = Actual CU
____ - ( ___ x ___ ) = ______


Light Loss Factors (LLF)


Luminaire Ambient Temp: Luminaire Dirt Depreciation:
Voltage Variation: Room Surface Depreciation:
Luminaire Surface Depreciation: Lamp Lumen Depreciation:
Ballast Factor: Lamp Burn Out:

_____ x _____ x _____ x _____ x _____ x _____ x _____ x _____ = _____ (Total LLF)


Calculations


# of Fixtures Required =
Target Average Illuminance Level x Area
# of Lamps/ Fixture x Lamp Lumens x CU x LLF

Illumination due to specific # of fixtures =
# of Fixtures x # of Lamps/Fixture x Lamp Lumens x CU x LLF
Area