Installation Techniques - Link-Seal Modular Seals: Connect
Installation Techniques - Link-Seal Modular Seals: Connect
Installation Techniques - Link-Seal Modular Seals: Connect
Connect
1. Center the pipe, cable or
conduit in wall opening or
casing. Make sure the pipe
will be adequately supported on both ends. LinkSeal modular seals are
not intended to support the
weight of the pipe.
Bulge
Installation Complete
5a. LS-325 thru. LS-650
Using a hand socket or offset wrench ONLY, start at
12 O Clock. Do not tighten
any bolt more than 4 turns
at a time. Continue in a
clockwise manner until
links have been uniformly
compressed. (Approx. 2 or
3 rotations)
6. Make 2 or 3 more
passes at 4 turns per bolt
MAXIMUM, tightening all
bolts clockwise until all
sealing elements bulge
around all pressure plates.
On type 316 stainless steel
bolts, hand tighten ONLY
without power tool.
Link-Seal Model
Tool Size/
Type Req.
LS-200, LS-275
4mm, Allen
LS-300, LS-315
6mm, Allen
13mm, Hex
17mm, Hex
19mm, Hex
LS-600
30mm, Hex
LS-650
19mm, Hex
Installation Notes: The Link-Seal modular seal bolt heads are usually recessed below
the wall opening or the edge of casing pipe and therefore a socket or offset wrench must
be used. Hand Tools: Review provided chart above. (Tools not provided.) Tools can be
purchased from hardware store, auto parts store, or home improvement store.
Dont
1. Dont Install the belt with
the pressure plates aimed
in irregular directions.
(Staggered)