Owners Manual DS/DSV/RS S010-080 Series Dehumidifier
Dectron, Inc. May 2005 49
Data subject to change without notice. Controller Interface Startup HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY Press and hold for 5 seconds to toggle between ON and OFF. DRY-O-TRON blower may not stop in OFF. See Options. Press to display alarm codes. When illuminated, indicates unit is ON. When illuminated, indicates cooling mode is ON. When illuminated, indicates ventilation mode is ON. When illuminated, indicates dehumidifi- cation mode is ON. When illuminated, indicates spa heating mode is ON. When illuminated, indicates auxiliary heating is ON. When illuminated, indicates the displayed variable is the indoor temperature. When illuminated, indicates the displayed variable is the indoor relative humidity. When illuminated, indicates the displayed variable is the pool water inlet temperature. When illuminated, indicates the displayed variable is the spa water inlet temperature. When illuminated, indicates the displayed variable is the outdoor temperature. When illuminated, indicates the displayed variable is the air flow rate. Flashes to indicate there is an active alarm. Press SERVICE button to view code. When illuminated, indicates pool heating mode is ON. Press repeatedly to select different values to be displayed. Press to display set points. Press again to lower set points. Press to display set points. Press again to raise set points. When illuminated, indicates the displayed variable has the units %. When illuminated, indicates the displayed variable has the units C. When illuminated, indicates the displayed variable has the units F. Value of selected variable In the event of a failure, will flash. Press to view the alarm code. After the cause of the alarm has been corrected, press and hold to clear the alarm code. SERVICE SERVICE SERVICE SYSTEM ON INDOOR HUMIDITY POOL SPA OUTDOOR AIRFLOW DS/DSV/RS 010-080 Series Dehumidifier Owners Manual Startup Interface Map 50 Dectron, Inc. May 2005 Data subject to change without notice. SYSTEM ON/OFF Displayed variable is indoor temperature. Displayed variable is indoor temperature set point. Press to increase the set point, or press to decrease the set point. Displayed variable is indoor relative humidity. Displayed variable is spa inlet water temperature. This will be skipped if programming does not allow for a spa. Displayed variable is pool inlet water temperature. This will be skipped if programming does not allow for a pool. Displayed variable is outdoor air temperature. This will be skipped if programming does not allow for an outdoor air temperature sensor. Displayed variable is return air flow rate in % of maximum. This will be skipped if programming does not allow for an air flow sensor. See calibration section for setup information. Displayed variable is indoor relative humidity set point. Press to increase the set point, or press to decrease the set point. Displayed variable is pool water temperature set point. Press to increase the set point, or press to decrease the set point. Displayed variable is spa water temperature set point. Press to increase the set point, or press to decrease the set point. HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY Owners Manual DS/DSV/RS S010-080 Series Dehumidifier Change Temperature Display Mode Startup Dectron, Inc. May 2005 51 Data subject to change without notice. HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY Your HT800 controller comes pre-programmed from the factory for the condi- tions determined at time of sale. If it is desired to change the temperature dis- play mode, e.g. from F to C, follow the steps below. Choose one of the dis- play codes according to the chart. NOTE: + indicates pressing two buttons at the same time. DISPLAY DISPLAY + hold 3 seconds OR x approx. 9 times Press Screen existing display code 1. 2. 3. 4. 5. temperature units default display room temperature Recommended-- Factory default Recommended for a remote location Recommended for a remote location Recommended-- Factory default return air sensor thermostat sensor return air sensor thermostat sensor return air sensor thermostat sensor return air sensor thermostat sensor room temperature set point set point room temperature room temperature set point set point room temperature measured by F F F F C C C C The temperature display mode is now set. The display will return to normal approximately 35 seconds after the last button is pressed. DS/DSV/RS 010-080 Series Dehumidifier Owners Manual Startup Set Pools Set Starting Delays 52 Dectron, Inc. May 2005 Data subject to change without notice. DISPLAY DISPLAY + for 3 seconds OR x approx. 9 times Press Screen existing display code 1. 2. 3. 4. 5. Pool water is connected to the DRY-O- TRON. Spa water is connected to the DRY-O- TRON. Give the spa heating priority. If the relative humidity is above 60% on com- pressor start, ignore evaporator tempera- ture sensor and force pool heating mode for 20 minutes. NO NO NO NO YES NO NO NO YES NO YES YES NO NO YES YES YES YES NO NO YES YES NO YES NO YES YES YES YES NO YES YES YES YES Set Pool Priority HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY Your HT800 controller comes pre-programmed from the factory for the condi- tions determined at time of sale. If it is desired to change a. the number of pools with water flow thorugh the DRY-O-TRON, or b. the heating priority of the pools, or c. the starting delays, then choose one of the display codes according to the chart below. For other condi- tions, consult Dectron or a Dectron-certified service technician. NOTE: + indicates pressing two buttons at the same time. NOTE: Pool water should be connected to DRY-O-TRON DS/RS units in order to re-cycle the lost pool heat. Lack of such connection and the necessary adjustments below should be temporary. The controller will return to normal approximately 35 seconds after the last button is pushed. Your HT800 controller comes pre-programmed from the factory for the conditions determined at time of sale. If conditions have changed so that it is necessary to change whether or not the unit will have an auxiliary pool water heater connected (see Installation - Wiring - Control Signals), or whether or not the unit will have an outdoor air tempera- ture sensor connected (see Installation - Wiring - Control Signals), or whether or not the unit has an airflow sensor, follow these steps. Choose one of the display codes according to the chart. NOTE: + indicates pressing two buttons at the same time. Set Air Flow Sensor Set Outdoor Temperature Sensor Set Auxiliary Pool Water Heater Startup Owners Manual DS/DSV/RS S010-080 Series Dehumidifier Dectron, Inc. May 2005 53 Data subject to change without notice. HT800 CONTROLLER ENERGY RECYCLINGDEHUMIDIFIER DEHUMIDIFY OUTDOOR AI RFLOW VENTILATION SPAHEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY DISPLAY DISPLAY + for 3 seconds OR x approx. 9 times Press Screen existing display code 1. 2. 3. 4. 5. latent- sensible heating mode auxiliary pool water heater auxiliary pool water heater also works as 2nd stage A/C option installed latent- sensible heating mode & auxiliary pool water heater airflow sensor option installed outdoor temperature sensor option installed NO NO NO NO NO NO NO NO NO NO NO NO NO YES NO NO NO NO NO YES NO NO NO NO NO NO YES YES NO NO NO NO YES NO NO NO NO NO NO YES NO YES NO NO NO NO YES YES NO NO NO NO NO YES YES YES NO NO YES NO NO NO NO NO NO YES NO NO NO YES NO NO YES NO NO YES NO NO NO YES NO NO YES YES NO NO YES NO YES NO NO NO NO YES NO YES NO YES NO NO YES NO YES YES NO NO NO YES NO YES YES YES NO NO YES YES NO NO NO NO NO YES YES NO NO YES NO NO YES YES NO YES NO NO NO YES YES NO YES YES NO NO YES YES YES NO NO NO NO YES YES YES NO YES NO NO YES YES YES YES NO NO NO YES YES YES YES YES The display will return to normal approximately 35 seconds after the last button is pressed. DS/DSV/RS 010-080 Series Dehumidifier Owners Manual Setup 54 Dectron, Inc. May 2005 Data subject to change without notice. This page is intentionally left blank. 1. Apply electric power If the disconnect switch for the remote condenser is not already ON, turn it ON now. This starts the compressor crankcase heaters. 2. Start blower On some units, the blower runs whenever electric power is applied to the unit. On other units, it will be necessary to press on the controller display until illuminates. The blower will start after a short delay. If the blower does not turn the proper direction, a qualified person should discon- nect electric power and interchange any two of the branch circuit wires at the DRY-O-TRON
input lugs. Do not
move any factory installed wires. 3. Check Air Distribution Be sure the air flow rate is correct before proceeding. Be sure that the air flow at each diffuser is correct. See Installation - Air Distribution - Adjust Airflow. This is necessary for the compressor crankcase heater function. 4. Enable compressor 1 For units with external overloads for the compressor, press START on the overload. For other units, turn ON the compressor emergency switch. Owners Manual DS/DSV/RS S010-080 Series Dehumidifier Enable Operation Startup Dectron, Inc. May 2005 55 Data subject to change without notice. SYSTEM ON/OFF IMPORTANT! This energy recycling dehumidification system has been completely tested under design conditions at the factory. Start-up must be performed by a qualified factory trained service and installation technician. Once start-up is completed, all portions of the Start-up Report and Warranty Registration form must be completely filled in and a copy must be sent to the Dectron representative or to the Dectron factory in order to register and validate the warranty. Important! Do NOT turn on the electric power unless the power supply voltage matches that specified on the unit nameplate. Be certain that there is no construction dust in the space or in the return duct. STOP HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY SYSTEM ON To read sensors other than INDOOR temperature, press as necessary to cause the LED next to the name of the desired quantity to illuminate. The numerical value in the screen is then the value of the indicated sensor. The display will return to INDOOR if is pressed again after the last available sensor has been shown. The display will return to INDOOR if no buttons are pushed for a preset time. DS/DSV/RS 010-080 Series Dehumidifier Owners Manual Startup Read Primary Sensors 56 Dectron, Inc. May 2005 Data subject to change without notice. Indoor temperature is displayed by default. Other sensors may be read by following the instructions below: HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY DISPLAY DISPLAY INDOOR HUMIDITY POOL SPA AIRFLOW DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY Displayed variable is present indoor temperature. Displayed variable is present indoor relative humidity. Displayed variable is present spa inlet water temperature. This will be skipped if programming does not allow for a spa. Displayed variable is present pool inlet water temperature. This will be skipped if programming does not allow for a pool. Displayed variable is return air flow rate in % of maximum. This will be skipped if programming does not allow for an air flow sensor. OUTDOOR Displayed variable is present outdoor air temperature. This will be skipped if programming does not allow for an outdoor air temperature sensor. Owners Manual DS/DSV/RS S010-080 Series Dehumidifier Read Secondary Sensors Startup Dectron, Inc. May 2005 57 Data subject to change without notice. To access the secondary sensors, press and at the same time, and hold them until illuminates. Use the table below to interpret the display. HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY INDOOR HUMIDITY POOL SPA AIRFLOW DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY Displayed variable is indoor temperature as measured at the return duct. Displayed variable is the temperature of the air leaving the evaporator. Displayed variable is spa outlet water temperature. This will be skipped if programming does not allow for a spa. Displayed variable is pool outlet water temperature. This will be skipped if programming does not allow for a pool. Future use OUTDOOR Displayed variable is supply air temperature. SERVICE SERVICE DISPLAY SERVICE DISPLAY SERVICE + If no buttons are pressed for a pre-set time, the display will automatically return to the primary sensors. DS/DSV/RS 010-080 Series Dehumidifier Owners Manual Startup View and Change Set Points 58 Dectron, Inc. May 2005 Data subject to change without notice. Some primary sensors have set points associated with them. To view and/or change these set points, follow the chart below: At any time, you may cease pressing buttons, and the display will return to normal after a delay. INDOOR HUMIDITY POOL SPA OUTDOOR AIRFLOW Displayed variable is indoor temperature. Displayed variable is indoor temperature set point. Press to increase the set point, or press to decrease the set point. Displayed variable is indoor relative humidity. Displayed variable is spa inlet water temperature. This will be skipped if programming does not allow for a spa. Displayed variable is pool inlet water temperature. This will be skipped if programming does not allow for a pool. Displayed variable is outdoor air temperature. This will be skipped if programming does not allow for an outdoor air temperature sensor. Displayed variable is return air flow rate in % of maximum. This will be skipped if programming does not allow for an air flow sensor. See calibration section for setup information. Displayed variable is indoor relative humidity set point. Press to increase the set point, or press to decrease the set point. Displayed variable is pool water temperature set point. Press to increase the set point, or press to decrease the set point. Displayed variable is spa water temperature set point. Press to increase the set point, or press to decrease the set point. DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY HT800 CONTROLLER ENERGY RECYCLING DEHUMIDIFIER DEHUMIDIFY OUTDOOR AIR FLOW VENTILATION SPA HEAT COOL AUX. HEAT POOL SYSTEM ON SERVICE SPA INDOOR HUMIDITY POOL HEAT % C F SYSTEM ON/OFF SERVICE DISPLAY