Uicktronic Multiwatt - One For Many: There Is Light. and There Is Osram

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

THERE IS LIGHT. AND THERE IS OSRAM.

A NEW GENERATION OF ECGs


QUICKTRONIC

MULTIWATT
ONE FOR MANY
1
1
1
2
3
4
ONE FOR
MANY:
THE NEW
GENERATION
OF
VERSATILE
ECGs.
ENTER THE GENERALS
To solve this problem of a
disproportionate number of
units, OSRAM has taken
a new route and developed
electronic control gear
that are so versatile that
they can be used for a wide
range of fluorescent lamps
of different wattages. The
new Generals are called
QUICKTRONIC

MULTIWATT.
A large number of different
ECGs matched to particular
types and wattages can now
be replaced by just four
MULTIWATT models.
For example, instead of eight
ECGs to cover the entire
range of T5 FH

fluorescent
lamps only one single-lamp
ECG and one two-lamp
ECG is now needed. The
two-lamp MULTIWATT ECG
can even be used to operate
two lamps of different
wattages.
And only one QUICKTRONIC

MULTIWATT ECG is needed


to operate 17 different
tubular and circular fluores-
cent and compact fluores-
cent lamps, each at maxi-
mum efficiency.
LOWER COST, GREATER
FLEXIBILITY
MULTIWATT ECGs from
OSRAM give luminaire
designers new freedom to
combine different types
of fluorescent lamp and
different wattages. The fact
that there is now only a small
number of different ECGs
means that storage costs are
reduced, less capital is tied
up, forward planning is made
easier and the logistics can
be made more efficient.
TOO MANY SPECIALISTS
Without putting too fine a
point on it, traditional
electronic control gear for
fluorescent lamps have been
reliable but depressingly
limited. Each ECG has been
perfectly matched to a
particular type of lamp and
a particular wattage. Over
the past few years there has
been a welcome increase in
the number of new, better
and more effective fluores-
cent lamp systems, with the
unfortunate result that the
number of different ECGs
has grown out of proportion.
This is a problem not only
because of the number of
different types that have to
be stocked and the amount
of capital that this ties up,
but also because it acts
as a brake on the flexibility
needed nowadays in
luminaire manufacture and
lighting design.
H
F
G
1
1
2
3
3
4
4
4
4
5
6
7
5
6
7
5
6
7
QUICKTRONIC

MULTIWATT
QT-FH 1x14-35/230-240
ONE INSTEAD OF FOUR
A single digital MULTIWATT
FH

ECG now covers all four


wattages (14, 21, 28 and
35 W) of the super-slim high-
intensity FH

T5 fluorescent
lamps instead of the four
previously needed.
Six new combinations
with two lamps of
different wattages,
e.g. FH

14 Wand FH

35 W
FH 14 W
FH 21 W
FH 28 W
FH 35 W
QT-FH 1x14/230-240
QT-FH 1x21/230-240
QT-FH 1x28/230-240
QT-FH 1x35/230-240
PERMISSIBLE LAMPS AND LAMP COMBINATIONS
QUICKTRONIC

MULTIWATT QT-FH 1x14-35/230-240


Permissible lamps Old ECGs
QT-FH 1x14-35/
230-240
2 x FH 14 W
2 x FH 21 W
2 x FH 28 W
2 x FH 35 W
QT-FH 2x14/230-240
QT-FH 2x21/230-240
QT-FH 2x28/230-240
QT-FH 2x35/230-240
PERMISSIBLE LAMPS AND LAMP COMBINATIONS
QUICKTRONIC

MULTIWATT QT-FH 2x14-35/230-240


Permissible lamps Old ECGs
QT-FH 2x14-35/
230-240
No deviations in
luminous flux compared
to old single-wattage
ECGs
No deviations in
luminous flux compared
to old single-wattage
ECGs
LESS
IS MORE.
QUICKTRONIC

MULTIWATT
QT-FH 2x14-35/230-240
ONE INSTEAD OF FOUR,
PLUS SIX NEW COMBINA-
TIONS
The two-lamp MULTIWATT
ECG for FH

lamps replaces
four single-wattage models
and opens up six new com-
binations of lamps of diffe-
rent wattages.
QUICKTRONIC

MULTIWATT
QT-M 1x26-42/230-240 S
ONE INSTEAD OF ELEVEN
17 different lamp types/
wattages can be operated
on the new MULTIWATT ECG
for (compact) fluorescent
lamps. It therefore replaces
eleven old ECGs.
QUICKTRONIC

MULTIWATT
QT-M 2x26-32/230-240 S
ONE INSTEAD OF SEVEN,
PLUS MORE THAN 100
WATTAGE COMBINATIONS
The two-lamp MULTIWATT
ECG for compact fluorescent
lamps takes over the work
of seven old ECGs. It can
operate two lamps of the
same wattage of 12 different
types or more than 100
possible combinations of
lamps of different wattages.
DULUX T/E and D/E 26 W
DULUX T/E 32 W
DULUX T/E 42 W
DULUX L and F 18 W
DULUX L and F 24 W
DULUX L and F 36 W
DULUX L 40 W
FC 22 W
FC 40 W
L 18 W
L 36 W
FQ 24 W
FQ 39 W
17 lamps
QT-T/E 1x26/230-240
QT-T/E 1x32/230-240
QT-T/E 1x42/230-240
QT 1x18/230-240
QT 1x24/230-240
QT 1x36/230-240
QT 1x40/230-240
QT-FC 1x22/230-240
QT-FC 1x40/230-240
QT 1x18/230-240
QT 1x36/230-240
QT-FQ 1x24/230-240
QT-FQ 1x39/230-240
11 ECGs
PERMISSIBLE LAMPS AND LAMP COMBINATIONS
QUICKTRONIC

MULTIWATT QT-M 1x26-42/230-240 S


Permissible lamps Old ECGs
More than 100 combi-
nations of two lamps of
different wattages
64 W
HF
, e.g. FC 40 W
and OSRAM DULUX

T/E
26 W
QT-M 1x26-42/
230-240 S
2 x DULUX T/E and D/E 26 W
2 x DULUX T/E 32 W
2 x DULUX L and F 18 W
2 x DULUX L and F 24 W
2 x DULUX L and F 36 W
2 x FC 22 W
2 x L 18 W
2 x FQ 24 W
12 lamps
QT-T/E 2x26/230-240
QT-T/E 2x32/230-240
QT 2x18/230-240
QT 2x24/230-240
QT 2x36/230-240
2 x QT-FC 1x22/230-240
QT 2x18/230-240
QT-FQ 2x24/230-240
7 ECGs
PERMISSIBLE LAMPS AND LAMP COMBINATIONS
QUICKTRONIC

MULTIWATT QT-M 2x26-32/230-240 S


Permissible lamps Old ECGs
QT-M 2x26-32/
230-240 S
No deviations in
luminous flux compared
to old single-wattage
ECGs
No deviations in
luminous flux compared
to old single-wattage
ECGs
1
1
2
3
3
4
4
4
4
5
6
7
5
6
7
This means that there are
no deviations in luminous
flux compared to old single-
wattage ECGs. We have
even managed to reduce the
lowest temperature for
reliable ignition with the
MULTIWATT ECGs to 20C.
Ignition time has been
reduced to less than
one second.
HIGH OSRAM QUALITY
STANDARDS
The same strict quality
standards that apply to the
OSRAM QUICKTRONIC

family also apply to


MULTIWATT ECGs:
Optimum operation of all
approved lamps within
their rated data
Lamp operation to
EN 60929 and IEC 929
Operational safety of the
ECGs to EN 60928 and
IEC 60928
End-of-life circuit for
safe shutdown at the end
of the lamps life
Automatic restart after
relamping
Cut-off technology with
disconnection of filament
heating for greater lumi-
naire efficiency, maximum
lamp life and minimum
self-heating
Good radio interference
suppression
Mains harmonic content
to EN 61000-3-2 and
IEC 1000-3-2
Immunity to EN 61547
and IEC 1547
Radio interference suppression for protection
class I and II luminaires
Long-life electrolytic capacitor (50000 h at 85C)
Low total harmonic distortion THD <10%
Overvoltage protection for 320 V for 24 h or 350 V for 2 h
OSRAM-IC ensures optimum operation of all lamps within
their rated data
End-of-life circuit for safe shutdown at the end of the
lamps life
Cut-off circuit ensures minimal losses, high resistance
to on/off switching and long life
NEW
BENEFITS
THANKS TO
INNOVATIVE
TECHNOLOGY
AND TRADITIONAL
OSRAM QUALITY.
OSRAM-IC INSIDE
AN INTEGRATED CIRCUIT
IN THE ECG ENSURES
PERFECT OPERATION
The heart of the new
versatile ECG technology of
QUICKTRONIC

MULTIWATT
is the OSRAM IC (integrated
circuit). It ensures that all
the lamps approved for use
with the MULTIWATT ECG
are operated at maximum
efficiency within their rated
data.
1
2
3
4
5
6
7
1
3
0

W
0
1

E

0
5
/
0
1




O
S
R
A
M

W
I




A
D





S
u
b
j
e
c
t

t
o

c
h
a
n
g
e

w
i
t
h
o
u
t

n
o
t
i
c
e
.

E
r
r
o
r
s

a
n
d

o
m
i
s
s
i
o
n
s

e
x
c
e
p
t
e
d
z
r
i
n
t
e
d

o
n

p
a
p
e
r

t
r
e
a
t
e
d

w
i
t
h

c
h
l
o
r
i
n
e
-
f
r
e
e

b
l
e
a
c
h
.
TECHNICAL DATA
THERE IS LIGHT. AND THERE IS OSRAM.
Lamp reference QT-FH 1x14-35/230-240 QT-FH 2x14-35/230-240
For lamps 1x FH 14/21/28/35 2x FH 14/21/28/35 in any combination
Lamp wattage 14/21/28/35 W 14/21/28/35 W
System wattage 16/24/31/38 W 31/46/61/77 W
Luminous flux 1200/1900/2600/3300 lm 2x 1200/1900/2600/3300 lm
Preheat time t <1 s t <1 s
Mains voltage 230/240 V 230/240 V
Voltage range (AC) 198 V254 V 198 V254 V
Voltage range (DC) 176 V254 V 176 V254 V
Mains current 0.08/0.1/0.13/0.16 A 0.15/0.2/0.26/0.33 A
Mains frequency 0; 5060 Hz 0; 5060 Hz
Operating frequency approx. 4550 kHz approx. 4550 kHz
Radio interference suppression acc. to EN 55015 acc. to EN 55015
Harmonic content acc. to EN 61000-3-2 acc. to EN 61000-3-2
Immunity acc. to EN 61547 acc. to EN 61547
Power factor 0.94 c/0.99 c/0.98 c/0.99 c 0.94 c/0.99 c/0.98 c/0.99 c
Ambient temperature range t
a
20C to +50C 20C to +50C
Casing temperature t
c
max. +70C max. +70C
Dimensions (l x w x h) 360 x 30 x 30 mm 360 x 30 x 30 mm
Hole spacing 350 mm 350 mm
Weight 280 g 300 g
Approval marks 0 i . 0 i .
QT-FH 2x14-35/230-240: different lamp wattages can be operated simultaneously on the ECG (e.g. FH 35 W and 14 W)
Lamp reference QT-M 1x26-42/230-240 S Lamp reference QT-M 2x26-32/230-240 S
HF lamp System Mains Luminous flux HF lamp System Mains Luminous flux
wattage wattage current at 25C wattage wattage current at 25C
For lamps (W
HF
) (W) (A) (lm) For lamps (W
HF
) (W) (A) (lm)
DULUX D/E 26 W 24 27 0.12 1750 2 x DULUX D/E 26 W 49 54 0.23 3500
DULUX T/E 26 W 24 27 0.12 1750 2 x DULUX T/E 26 W 49 54 0.23 3500
DULUX T/E 32 W 32 35 0.15 2400 2 x DULUX T/E 32 W 64 70 0.30 4800
DULUX T/E 42 W 42 46 0.20 3200 2 x DULUX L 18 W 32 35 0.16 2300
DULUX L 18 W 16 18 0.09 1150 2 x DULUX L 24 W 49 54 0.23 3500
DULUX L 24 W 23 26 0.12 1750 2 x DULUX L 36 W 64 70 0.30 5600
DULUX L 36 W 32 35 0.15 2800 2 x DULUX F 18 W 32 35 0.16 2100
DULUX L 40 W 40 44 0.19 3500 2 x DULUX F 24 W 49 54 0.23 3300
DULUX F 18 W 16 18 0.09 1050 2 x DULUX F 36 W 64 70 0.30 5400
DULUX F 24 W 23 26 0.12 1650 2 x L18 W 32 35 0.16 2600
DULUX F 36 W 32 35 0.15 2700 2 x FC 22 W 49 54 0.23 3600
L18 W 17 19 0.09 1300 1 x FC 22 W + 40 W 64 70 0.30 1800 + 3200
L36 W 32 35 0.15 3200 2 x FQ 24 W 49 54 0.23 3500
FC 22 W 23 26 0.11 1800
FC 40 W 40 44 0.18 3200
FQ 24 W 24 27 0.12 1750
FQ 39 W 37 40 0.17 3000
Preheat time t <1 s Preheat time t <1 s
Mains voltage 230/240 V Mains voltage 230/240 V
Voltage range (AC) 198 V254 V Voltage range (AC) 198 V254 V
Voltage range (DC) 176 V254 V Voltage range (DC) 176 V254 V
Mains frequency 0; 5060 Hz Mains frequency 0; 5060 Hz
Operating frequency approx. 45 kHz Operating frequency approx. 45 kHz
Radio interference suppression acc. to EN 55015 Radio interference suppression acc. to EN 55015
Harmonic content acc. to EN 61000-3-2 Harmonic content acc. to EN 61000-3-2
Immunity acc. to EN 61547 Immunity acc. to EN 61547
Power factor 0.97c Power factor 0.97c
Ambient temperature range t
a
20C to +50C Ambient temperature range t
a
20C to +50C
Casing temperature t
c
max. +70C Casing temperature t
c
max. +70C
Dimensions (l x w x h) K2 (103 x 67 x 31 mm) Dimensions (l x w x h) K3 (123 x 79 x 33 mm)
Hole spacing 110 mm Hole spacing 129.5 mm
Weight 160 g Weight 240 g
Approval marks 0 i . Approval marks 0 i .