G.saminathan 11012014
G.saminathan 11012014
G.saminathan 11012014
Saminathan
Mobile: +974 33494588, Tel: +974 44820463, Email: [email protected]
Seeking a challenging assignment as
Professional Overview
Technical Competencies
Approved Commissioning engineer for Main protection relays of Siprotec in the SEC network.
Approved Commissioning engineer for Station Automation system(SAS) in the SEC network.
Approved Commissioning engineer for Static Var Compensator system (SVC) in the SEC network.
Managing all activities related to Project Management like coordination with site engineers, resource
planning, scheduling, monitoring the progress and ensuring that the project is executed in time and
within set budgeted cost.
Identifying critical activities for the project and giving topmost attention to resolve them within
scheduled time to avoid possible bottlenecks and delay in execution.
Budgeting, planning and indenting and mobilization of materials and manpower as per the requirement.
Operations / Maintenance
Handling the routine operations, preventive maintenance and trouble shooting activities to achieve high
productivity by reducing breakdown time.
Analyzing each process and machinery involved regarding their specified safety parameters to ensure
a safe working environment.
Conducting enquiries and investigations of failures, monitoring all the processes involved to take
corrective action.
Identifying areas and opportunities of improvement, recommending process modifications.
Erection & Commissioning
Anchoring erection & commissioning of machines & equipments and ensuring completion of project in
minimum turnaround time effective resource utilization to maximize the output.
Overseeing installation & commissioning as well as conducting inspections to ensure operational
effectiveness of utilities; planning & effectuating maintenance plans for machines and equipments
Performing root cause failure analysis of repetitive breakdowns occurring in the plant and taking
corrective measures for the same.
Team Management
Delegating duties to team members as per the project schedule,
Interacting with functional heads for obtaining a smooth workflow.
Monitoring the performances of team members and motivating them to complete the projects in the
given time and cost parameters.
Career Summary
Professional Experience
OCT 2012 Present
Training
Undergone advanced training of AREVA Protection relays covering MICOM P44X & P54X Series
Riyadh ,Saudi Arabia
Undergone advanced training of SEL Protection relays covering (311L,351A,421) Riyadh ,Saudi
Arabia
Undergone advanced training of Siemens siprotec Protection relays covering 7SA522,7SD522
Riyadh ,Saudi Arabia
Undergone advanced training of Siemens siprotec Protection relays covering 7SA5,7SD,7UT,7SS
NUREMBERG ,GERMANY (2 weeks)
Undergone advanced training of Siemens STATION AUTOMATION SYSTEM SAS (SICAM PAS)
NUREMBERG ,GERMANY (2 weeks)
Undergone TWO Months On Job training of Siemens STATION AUTOMATION SYSTEM SAS
(SICAM PAS) EARLONGAN ,GERMANY
Overseas experience:
Commissioning executed in QATAR (protection)
Review of Protection drawings / documents and approving the same as per specifications.
CT/VT sizing and Cable sizing calculations.
Exposure in Relay settings Calculations.
Co-ordinating with Kahraama Engineers during review and approval of drawings.
Organising and leading Design review meetings with the EPC contractor (HYOSUNG, SIEMENS) to
discuss critical design issues.
Review of remote end site survey reports with respect to scope/price schedule and provide
necessary techno-commercial feedback to the Project Manager.
Supervise the contractor in the execution of precommissioning, erection completion,
commissioning & start-up activities .
Ensure that all site activities, QC certifications,the Contractor erection Completion and
Ready for Start-Up for the respective elements of subsystems, systems, and facilities are
correct and complete as per Company requirements.
Ensuring a safe and timely completion of precommissioning, erection completion,
commissioning & start-up activities, inclusive of effective work-around proposals /
implementation to ensure safety, quality and schedule when delays or constraints are
encountered.
Witness for commissioning of Relays of ABB, Siemens & Alstom.
Remote end modifications design works.
Coordination with site for problem solving/trouble shooting.
Protection design coordination with KAHRAMAA/contractors.
Review and approval all Protection and scheme related Site Acceptance test Reports.
Organising NOSP inspections with KM.
Protection Final settings.
Final trip test.
Protection End to End testing.
Overall protection stability test.
Bus bar & transformer stability test.
Energization of sub stations.
Client
Client :
SCMS system ,network devices ,GPS device & serial hub installation, Software installation.
Base design, signal list preparation
Creation of DIGSI project, definition & marshalling of DIGSI variables
Construction of BCU pictures, creation of CFC plans
Simatic WINCC graphic designer, construction of HMI pictures using SICAMPAS CC
Tag management ,Alarm & Event logging
Data base creation, PASCC configuration ,mapping, GOOSE configuration
SCMS database simulation by usage of value viewer, SCADA simulation by IEC test
FAT & SAT test protocol preparation, Signal list verification.
Power(Oil& Gas)plant 5 SVC Hitteen (S/S 9005) Client: SEC, SAUDI ARABIA
380 KV,132 KV,33KV GIS Equipment, CT,VT Testing & Scheme Checks
132 KV Relay panel Scheme Checks
380 KV,132 KV ,33kV Bus Bar Protection Scheme Checks, Stability & Sensitivity Checks
7UT635,SEL 351A,7SJ62 relay testing
33 KV,21.5 KV Capacitor, reactor ,resistor , disconnector ,earth switch testing , Filter tuning test
125V battery Systems, LVAC Testing & Scheme Checks
SIMATIC TDC data base creation, Mapping ,configuration process
WIN CC graphical display creation, Network switch configuration
Signal list preparation & verification, Interlock preparation & verification
NEW QASSIM -2 (9025) 380/132 /13.8 KV S/S at Qassim (Riyadh) Client: SEC, SAUDI ARABIA
Power Plant (Oil& Gas)10 (9023) 380/132 KV S/S at Riyadh Client: SEC, SAUDI ARABIA
Power Plant(Oil& Gas) 9 (9019) 380/132 KV S/S at Riyadh Client: SEC, SAUDI ARABIA
QURRAYAT power(Oil& Gas) Plant (380KV/132KV/13.8 KV) ( S/S 9035) Client: SEC, SAUDI
ARABIA
Power plant (Oil& Gas) 8 (9021) 380/132 KV S/S at Riyadh Client: SEC, SAUDI ARABIA
Commissioning executed in ABUDHABI,UAE
NEW 220/33/11 KV S/S at Ramah (Abu Dhabi), Consultant: SWED POWER, Client : ADWEA
NEW 220/33/11 KV S/S at Gayathy (Abu Dhabi), Consultant: SWED POWER, Client : ADWEA
132/11 KV S/S at Delmah (Abu Dhabi) Consultant: MML , Client : ADWEA
220/132 KV S/S at Shuwaihat (Abu Dhabi) Consultant: MML , Client : ADWEA
380 KV,220 KV,132 KV,33KV,13.8 KV,11 KV GIS Equipment ,CT,VT Testing & Scheme Checks
Domestic experience:
Projects:
2X500 MW Tarapur Atomic Power Project client: (NPCIL) supplied by L&T ECC India
Commissioning ,Operations & maintenance.
2X120 MW Thermal Power Station Refurbishment work client: (CSEB) Korba, Chhattisgarh
supplied by SIEMENS India- Commissioning ,Operations & maintenance.
66/11 kV Switchyards Client: Birla Textile Mills, Himachal Pradesh Through SIEMENS- Erection &
commissioning
6.6KV/0.433KV Sub Station Client: Bharat Petroleum Corporation Ltd (BPCL), Bombay,
ThrougH L&T ECC
6.6kv switchgear systems Client: Gas Authority of India LTD (GAIL), Uttar Pradesh. Through
ALSTOM
66/11 KV Substation. Client: North Delhi Power Corporation Ltd (NDPL), Delhi. Through ABB
66/11 KV Substation.
Karnataka. Through ABB
400/220 KV Substation at Amritsar Client: POWER GRID CORPORATION INDIA LTD (PGCIL),
Through L&T ECC
400/220 KV Substation at Jalandar
(PGCIL), Through L&T ECC
630 MVA Generator Transformer Test, 35 MVA Unit Transformer,70 MVA Start up Transformer ,315
MVA Auto Transformer Scheme test with (differential & restricted earth fault protections) stability
checks, 21KV/240V Neutral Grounding Transformers
21 kV Integrated phase Bus duct (IPBD).CT,VT Testing
Generator Protection relays co-ordination, GTTM 22 Over fluxing Protection.
MBCH 16 Overall Diff. Protection, KBCH 140 Diff. Protection GT, U.T & SUT s
P123, P127,P220,P121,SAPJ110C,SPAC112C,7SJ61,CTMM & CTNM relay testing
MFVUM 21 Under/Over Frequency, CTIGM 15 over Current during Starting Relay.
400 kV &220KV Fast / slow Transfer device Comm. Co-ordination
24 KV & 19.1KA Generator Circuit Breaker Scheme Test & Comm. Co-ordination
21 KV GCB/ 400 KV Bus Coupler/400 KV GTCB Synchronizing Scheme Comm. Co-ordination
Executed Commissioning of HT (up to 3.5 MW) & LT Motors 6.6 kV Switchgear panels, PCCs,
HT/LT Motors,
Executed Commissioning of 11 kV, 6.6 kV Switchgear panels, PCCs, HT/LT Motors
Responsibilities of Leading the Maintenance team during Major overhauls and Plant shutdown.
Execution of Predictive, preventive, premature and breakdown maintenance
Planning and execute job with stipulated time during maintenance
Reinforce the team and diplomatic ways of handling such crucial situation to achieve targets
Effectively minimize the consumables
Strictly follow the Standard Maintenance Procedure and ensure the quality of maintenance carried
out.
Reduce the defects and failures to maintain high reliability
Ensuring the safety precautions for all kind of maintenance
Education
Course
Institution
Year of Passing
Bachelor of
Engineering
(Electrical
&Electronics)
April 2003
Personal Details
Fathers Name :
C .Ganapathy
Passport number: E9020334
Date of Issue : 21.04.2004
Permanent Address
Driving License :
Qatar ,Saudi