Boiler Instrumentation and Controls
Boiler Instrumentation and Controls
Boiler Instrumentation and Controls
com
INTRODUCTION
1
Boiler Instrumentation and Controls www.bestneo.com
CONTROL LOOPS
Combustion controls
Feedwater control
2
Boiler Instrumentation and Controls
3
FIG. 1. GENERAL BLCOK DIAGRAM OF BOILER DRUM
www.bestneo.com
Boiler Instrumentation and Controls www.bestneo.com
4
Boiler Instrumentation and Controls www.bestneo.com
COMBUSTION CONTROL
The primary boiler fuels are coal, oil and gas. The control of gas
and oil fuels requires simplest controls- ie, a control valve in the fuel line.
5
Boiler Instrumentation and Controls www.bestneo.com
STEAM
AIR FLOW FUEL FLOW
PRESSURE
(a) Series
AIR FLOW
STEAM
PRESSURE
FUEL FLOW
(b) Parallel
STEAM
FUEL FLOW
PRESSURE
6
Boiler Instrumentation and Controls www.bestneo.com
7
Boiler Instrumentation and Controls www.bestneo.com
8
Boiler Instrumentation and Controls www.bestneo.com
FEEDWATER CONTROL
Proper boiler operation requires that the level of water in the steam
drum should be maintained within certain band. A decrease in this level
may uncover boiler tubes, allowing them to become overheated. An
increase in the level of water may interfere with the internal operation of
internal devices in the boiler drum. It is important to made that the water
level in the boiler drum must be above 50% all the time.
The water level in the boiler drum is related to, but is not a direct
indicator of , the quantity of water in the drum. At each boiler load, there is
different volume in the water that is occupied by steam bubbles. So if load
is increased there are more steam bubbles and this cause water to ‘swell’ or
rise, rather than fall because of added water usage.
9
Boiler Instrumentation and Controls www.bestneo.com
10
Boiler Instrumentation and Controls www.bestneo.com
For small boilers having relatively high storage volumes and slow
changing loads ,single element control system is used. It controls feed water
flow based on drum level. Response is very slow because a change in
feedwater flow takes a long time to show up the level change. As a result
the steam drum causes water to increase and decrease in volume, resulting
in false measurements.
Boilers that experiences wide and rapid load changes require three
element control. Three element control is similar to two element system
except that the water flow loop is closed rather than open.
11
Boiler Instrumentation and Controls www.bestneo.com
STEAM
X FT 2
LT3
DRUM Computing
X Level Relay
Controller
Feedwater
FC
Flow
Controller
X FT
1
FV Feedwater
12
Boiler Instrumentation and Controls www.bestneo.com
13
Boiler Instrumentation and Controls www.bestneo.com
STEAM
TT X FT
5 2
Temperature
X compensated
steam flow
PT f(x)
4
Pressure
Compensated
Drum Level
DRUM Computing
Level Relay
Controller
FC
Flow
Controller
X FT
1
FV Feedwater
14
Boiler Instrumentation and Controls www.bestneo.com
Types of steam
Here we are using two types of steam i.e, saturated steam and super
heated steam. Steam obtained while heating is called saturated steam. It is
called wet steam since moisture content is also present. Super heated steam
is obtained when saturated steam is further heated above 220 degrees. It is
also called dry steam.
15
Boiler Instrumentation and Controls www.bestneo.com
STEAM
TT X FT
5 2
Temperature
X compensated
steam flow
PT f(x)
4
Pressure
Compensated
LT3 Drum Level
DRUM Computing
X X Level Relay
Controller
FT f(x)
6 FC
Drum Blowdown
Boiler Tube
Flow
Controller
FT f(x)
7
Tubes Blowdown
X FT
1
Economiser
FV Feedwater
16
Boiler Instrumentation and Controls www.bestneo.com
ADVANTAGES
DISADVANTAGES
17
Boiler Instrumentation and Controls www.bestneo.com
FUTURE DIRECTIONS
CONCLUSIONS
18