MDS Radio 9810 User Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 80

I

n
s
t
a
l
l
a
t
i
o
n

a
n
d

O
p
e
r
a
t
i
o
n

G
u
i
d
e
I
n
s
t
a
l
l
a
t
i
o
n

&

O
p
e
r
a
t
i
o
n

G
u
i
d
e

MDS 05-3301A01, Rev. C
JULY 2004

900 MHz Spread Spectrum
Data Transceivers

Microwave Data Systems Inc.

MDS 9810

QUICK START GUIDE

Below are the basic steps for installing the transceiver. Detailed instructions are given in INSTALLA-
TION on Page 14 of this guide.

1. Install and connect the antenna system to the radio

Use good quality, low-loss coaxial cable. Keep the feedline as short as possible.
Preset directional antennas in the direction of desired transmission.

2. Connect the data equipment to the radios INTERFACE connector

Connection to the radio must be made with a DB-25 Male connector. Connections for typical sys-
tems are shown below.
Connect only the required pins. Do not use a straight-through RS-232 cable with all pins wired.
Verify the data equipment is congured as DTE. (By default, the radio is congured as DCE.)

3. Apply DC power to the radio

Observe proper polarity. The red wire is the positive lead; the black is negative.

4. Set the radios basic conguration with a Hand-Held Terminal (HHT)

Set the baud rate/data interface parameters as follows. Use the

BAUD xxxxx abc

command,
where

xxxxx

equals the data speed and

abc

equals the communication parameters as follows:

a

= Data bits (7 or 8)

b

= Parity (N for None, O for Odd, E for Even

c

= Stop bits (1 or 2)
(Example:

BAUD 9600 8N1

) NOTE: 7N1, 8E2 and 8O2 are invalid data parameters.

5. Verify proper operation by observing the LED display

Refer to Table 4 on Page 26 for a description of the status LEDs.
Rene directional antenna headings for best received signal strength using the

RSSI

command.
If difculties are encountered, please refer to Table 14 on Page 56 for troubleshooting help.
DB-25 DB-25
2
3
2
3
4
5
20
6 DSR DSR 6
TXD
RXD
GND
RTS
CTS
TXD
RXD
GND
4
CTS 5
RTS
DB-9 DB-25
DB-9 to DB-25 Example DB-25 to DB-25 Example
1 1
4
5
2
3
3
2
5
20
7
RXD
TXD
DCD
GND
DSR
RTS
RXD
TXD
DCD
GND
As required for application
5
1 8
7
6
CTS
DSR
RTS
CTS 8
6
4
5 7 7 GND GND
8 8 DCD DCD
As required for application
R
T
U
(
D
T
E
)
T
R
A
N
S
C
E
I
V
E
R
(
D
C
E
)
R
T
U
(
D
T
E
)
T
R
A
N
S
C
E
I
V
E
R
(
D
C
E
)

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide i

TABLE OF CONTENTS

1.0 ABOUT THIS MANUAL......................................................................................................... 1

2.0 PRODUCT DESCRIPTION................................................................................................... 1

Transceiver Features........................................................................................................................ 2
Model Conguration Codes ............................................................................................................. 2
2.1 Spread Spectrum RadiosHow Are They Different? .................................................................... 3
2.2 Typical Applications ....................................................................................................................... 3
Multiple Address Systems (MAS) .................................................................................................... 3
Simplex Peer-to-Peer..................................................................................................................... 4
Peer-to-Peer with Repeater Assistance ........................................................................................... 4
Point-to-Point System....................................................................................................................... 5
Tail-End Link (MAS Extension) ...................................................................................................... 5
Repeater SystemTraditional ......................................................................................................... 6
Single-Radio RepeaterAlternative Method................................................................................. 6
2.3 Accessories ................................................................................................................................... 7

3.0 INSTALLATION PLANNING.................................................................................................. 7

3.1 General Requirements .................................................................................................................. 7
3.2 Site Selection ................................................................................................................................ 8
Terrain and Signal Strength ............................................................................................................. 9
Conducting a Site Survey ................................................................................................................ 9
3.3 A Word About Radio Interference ................................................................................................ 10
3.4 Antenna & Feedline Selection ..................................................................................................... 11
Antennas........................................................................................................................................ 11
Feedlines ....................................................................................................................................... 12
3.5 How Much Output Power Can be Used? ..................................................................................... 13
Transmitter Power vs. Antenna System Gain................................................................................. 13

4.0 INSTALLATION................................................................................................................... 14

4.1 Transceiver Installation ................................................................................................................ 15
4.2 Peer-to-Peer Systems ................................................................................................................. 19
Simplex Peer-to-Peer ..................................................................................................................... 19
Peer-to-Peer with Repeater Assistance ......................................................................................... 20
4.3 Tail-End Links .............................................................................................................................. 21
Interface Wiring.............................................................................................................................. 21
Programming ................................................................................................................................. 22
4.4 RepeatersTraditional Method ................................................................................................... 22
Antennas........................................................................................................................................ 23
System Addresses......................................................................................................................... 23
Interface Wiring.............................................................................................................................. 23
Diagnostic Limitations.................................................................................................................... 23

ii MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
4.5 Single-Radio RepeaterAlternative Method ............................................................................ 24
Interface Wiring.............................................................................................................................. 24
Software Programming (TDD Command) ...................................................................................... 24
Limitations of Single-Radio Repeaters........................................................................................... 25
4.6 Using the Radios Sleep Mode .................................................................................................... 25
Sleep Mode Example..................................................................................................................... 25

5.0 OPERATION....................................................................................................................... 26

5.1 Initial Start-up .............................................................................................................................. 26
5.2 Performance Optimization ........................................................................................................... 26
Antenna Aiming.............................................................................................................................. 27
Antenna SWR Check ..................................................................................................................... 27
Data Buffer Setting......................................................................................................................... 27
Hoptime Setting ............................................................................................................................. 27
Baud Rate Setting.......................................................................................................................... 28
Radio Interference Checks............................................................................................................. 28

6.0 PROGRAMMING................................................................................................................ 28

6.1 Hand-Held Terminal Connection & Start-up ................................................................................ 28
6.2 Hand-Held Terminal Setup .......................................................................................................... 29
6.3 Keyboard Commands .................................................................................................................. 30
Entering Commands ...................................................................................................................... 30
Error Messages.............................................................................................................................. 31
6.4 Detailed Command Descriptions ................................................................................................. 35
ADDR [1...65000]........................................................................................................................... 36
AMASK [0000 0000FFFF FFFF].................................................................................................. 36
ASENSE [HI/LO] ............................................................................................................................ 36
BAUD [xxxxx abc] .......................................................................................................................... 36
BUFF [ON, OFF] ............................................................................................................................ 37
CTS [0255]................................................................................................................................... 37
CTSHOLD [0-6000]........................................................................................................................ 38
DEVICE [DCE, CTS KEY]............................................................................................................. 38
DLINK [xxxxx] ................................................................................................................................ 39
DMGAP [xx] ................................................................................................................................... 39
DTYPE [NODE/ROOT/GATE/PEER] ............................................................................................. 39
HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG] ................................................. 40
INIT ................................................................................................................................................ 41
MODE [M, R, R-M]......................................................................................................................... 41
OWM [xxxxx] .................................................................................................................................. 42
OWN [xxxxx] .................................................................................................................................. 42
PWR [xx30] .................................................................................................................................. 42
RSSI............................................................................................................................................... 42
RTU [ON/OFF/0-80] ....................................................................................................................... 43
RX [xxxx]........................................................................................................................................ 43
RXTOT [NONE, 01440]................................................................................................................ 43
SEND [n, -n, +n]............................................................................................................................. 43
SETUP........................................................................................................................................... 44
SHOW [PORT, DC, PWR] .............................................................................................................. 45
SIMPLEX [ON, OFF]...................................................................................................................... 45

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide iii
SKIP [NONE, 1...8] ........................................................................................................................ 46
SKIPSYNC [ON/OFF] .................................................................................................................... 46
SNR ............................................................................................................................................... 46
SREV............................................................................................................................................. 47
STAT............................................................................................................................................... 47
TDD [ON/OFF] ............................................................................................................................... 47
TEMP............................................................................................................................................. 48
TX [xxxx] ........................................................................................................................................ 48
UNIT [1000065000]...................................................................................................................... 48
ZONE DATA ................................................................................................................................... 49
ZONE CLEAR................................................................................................................................ 50

7.0 TROUBLESHOOTING........................................................................................................ 50

7.1 LED Indicators ............................................................................................................................. 50
7.2 Alarm Codes ................................................................................................................................ 51
Checking for AlarmsSTAT command.......................................................................................... 51
Major Alarms vs. Minor Alarms ...................................................................................................... 51
Alarm Code Denitions .................................................................................................................. 52
7.3 Performing Network-Wide Remote Diagnostics .......................................................................... 53
DLINK [xxxxx] ................................................................................................................................ 55
DTYPE [NODE/ROOT/GATE/PEER] ............................................................................................. 55
7.4 Troubleshooting Chart ................................................................................................................. 56

8.0 TECHNICAL REFERENCE................................................................................................. 56

8.1 Technical Specications .............................................................................................................. 56
8.2 RSSI Checks with a Voltmeter ..................................................................................................... 58
8.3 Data Interface Connections (DB-25) ........................................................................................... 58
8.4 Bench Testing Setup .................................................................................................................... 61
8.5 Using Radio Conguration Software ........................................................................................... 61
Connecting a PC............................................................................................................................ 62
Upgrading the Radios Software .................................................................................................... 62
8.6 dBm-Watts-Volts Conversion Chart ............................................................................................. 63

9.0 GLOSSARY OF TERMS..................................................................................................... 63

Copyright Notice

This Installation and Operation Guide and all software described herein are protected by

copy-
right: 2004

Microwave Data Systems

Inc. All rights reserved.
Microwave Data Systems reserves its right to correct any errors and omissions in this document.

Operational Safety Notice

The radio equipment described in this guide emits radio frequency energy. Although the power
level is low, the concentrated energy from a directional antenna may pose a health hazard. All
antennas used with this transmitter, whether indoor or outdoor mounted, must be installed to pro-
vide a separation distance of at least

23 cm

from all persons, and must not be co-located or oper-
ating in conjunction with any other antenna or transmitter. In mobile applications (vehicle
RF
Exposure

iv MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C

mounted) the above separation distance must be maintained at all times. More information on RF
exposure is available on the Internet at

www.fcc.gov/oet/info/documents/bulletins

. This manual
is intended to guide a professional installer to install, operate and perform basic system mainte-
nance on the described radio.

CSA/

US

Notice

This product is available for use in Class I, Division 2, Groups A, B, C & D Hazardous Locations. Such
locations are defined in Article 500 of the National Fire Protection Association publication NFPA 70, oth-
erwise known as the National Electrical Code.
The product has been recognized for use in hazardous locations by the Canadian Standards Association
(CSA), which also issues the US mark of approval (CSA/

US

). The CSA Certification is in accordance with
CSA STD C22.2 No. 213-M1987. The product has been evaluated in accordance with the following stan-
dards:
CSA Std C22.2 No. 142-M1987 - Process Control Equipment
CSA Std C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for Use in Class I, Division 2
Hazardous Locations
ANSI/UL Std No. 508 - Industrial Control Equipment
UL Std No. 1604 - Electrical Equipment for Use in Class I and II, Division 2; Class III Hazardous (Clas-
sified) Locations

ISO 9001 Registration

Microwave Data Systems' adherence to this internationally accepted quality system standard pro-
vides one of the strongest assurances of product and service quality available.

MDS Quality Policy Statement

We, the employees of Microwave Data Systems, are committed to achieving total customer satis-
faction in everything we do.

Total Customer Satisfaction in:

Conception, design, manufacture and marketing of our products.
Services and support we provide to our internal and external customers.

Total Customer Satisfaction Achieved Through:

Processes that are well documented and minimize variations.
Partnering with suppliers who are committed to providing quality and service.
Measuring our performance against customer expectations and industry leaders.
Commitment to continuous improvement and employee involvement.

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide v

FCC Notice, U.S.A.

The transceiver complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This device is specifically designed to be used under Section 15.247 of the FCC Rules and Regu-
lations. Any unauthorized modification or changes to this device without the express approval of
Microwave Data Systems may void the users authority to operate this device.
Furthermore, this device is indented to be used only when installed in accordance with the instruc-
tions outlined in this manual. Failure to comply with these instructions may also void the users
authority to operate this device.

Manual Revisions/Updates

While every reasonable effort has been made to ensure the accuracy of this manual, product
improvements may result in minor differences between the manual and the product shipped to you.
If you have additional questions or need an exacts specification for a product, please contact our
Customer Service Team using the information at the back of this guide. In addition, manual
updates can often be found on the MDS Web site at www.microwavedata.com.

vi MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 1

1.0 ABOUT THIS MANUAL

This guide presents installation and operating instructions for the
MDS 9810 transceiver. Following installation, we suggest keeping this
guide near the equipment for future reference.

NOTE:

Earlier versions of this manual also covered the MDS 24810
(2.4 GHz) transceiver, which has been discontinued by MDS.
An electronic version of the earlier manual is available for

download at www.microwavedata.com.

2.0 PRODUCT DESCRIPTION

The transceiver, shown in Figure 1, is a spread spectrum radio designed
for license-free operation in the 900 MHz frequency band. Employing
microprocessor control and Digital Signal Processing (DSP) tech-
nology, the unit is highly reliable for long-distance communications,
even in the presence of weak signals or interference.
DSP technology also makes it possible to obtain information about radio
operation and troubleshoot problems, without going to the remote radio
site. Using the appropriate software at the master station, diagnostic data
can be obtained on any DSP radio in the system, even while payload
data is being transmitted. (See Performing Network-Wide Remote
Diagnostics on Page 53.)
The transceiver is housed in a compact and rugged die-cast aluminum
case that need only be protected from direct exposure to the weather. It
contains a single printed circuit board with all necessary components for
radio operation. No jumper settings or adjustments are required to con-
figure the radio for operation.

Invisible place holder

Figure 1. MDS 9810 Transceiver
EXTERNAL
INTERFACE
CONNECTOR
(DB-25)
DIAGNOSTICS
CONNECTOR (RJ-11)
13.8 VDC POWER
CONNECTOR
ANTENNA CONNECTOR
(TYPE N)
SERIAL NUMBER
LABEL
LED INDICATORS (4)

2 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C

Transceiver Features

Listed below are several key features of the transceiver. These are
designed to ease the installation and configuration of the radio, while
retaining the ability to make changes in the future.
1,019 frequencies over 902928 MHz, subdivided into eight
frequency zones
Configurable operating zones to omit frequencies with constant
interference
65,000 available network addresses
Network-wide configuration from the master station; eliminates
most trips to remote sites
Data transparencyensures compatibility with virtually all
asynchronous SCADA system RTUs
Peak-hold RSSI, averaged over eight hop cycles
Operation at up to 19200 bps continuous data flow;
38400 bps non-continuous
Same hardware for all supported data rates:
1200, 2400, 4800, 9600, 19200, 38400 bps asynchronous
Same hardware for master or remote configuration
Data latency typically less than 10 ms
Supports EIA-232 (formerly called RS-232) user interface
Low current consumption30 mA or less average draw in
sleep mode.

Model Configuration Codes

The radio model number is printed on the end of the radio enclosure, and
provides key information about how the radio was configured when it
left the factory. See Figure 2 for an explanation of the model number
characters.

Invisible place holder

Figure 2. Transceiver Model Configuration Codes
98
PACKAGE
1= Transceiver only
OPERATION
X= Remote/Master
POWER SETTING
1= 10.5 - 30 Vdc*
DIAGNOSTICS
0= None
1= Non-Intrusive
N= N/A
SAFETY APPROVAL
N= N/A
MOUNTING BRACKETS
A= Standard
B= None
0 X N
AGENCY APPROVAL
F= FCC/IC
U= FM/UL/CSA
* Units shipped prior to Revision U (November 1999) may be configured for 25 Vdc maximum DC input.
THIS INFORMATION IS
SUBJECT TO CHANGE.
DO NOT USE FOR
PRODUCT ORDERING.

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 3

Invisible place holder

2.1 Spread Spectrum RadiosHow Are They
Different?

The main difference between a traditional (licensed) radio system and
the MDS 9810 transceiver is that these units hop from channel to
channel many times per second using a specific hop pattern applied to
all radios in the network. A distinct hopping pattern is provided for each
of the 65,000 available network addresses, thereby minimizing the
chance of interference with other spread spectrum systems. In the USA,
and certain other countries, no license is required to install and operate
this type of radio system.

2.2 Typical Applications

Multiple Address Systems (MAS)

This is the most common application of the transceiver. It consists of a
central control station (master) and two or more associated remote units,
as shown in Figure 3. An MAS network provides communications
between a central host computer and remote terminal units (RTUs) or
other data collection devices. The operation of the radio system is trans-
parent to the computer equipment. When used in this application, the
transceiver provides an excellent alternative to traditional (licensed)
MAS radio systems.

Invisible place holder

Figure 3. Typical MAS Network
RTU
RTU
RTU
RTU
RTU
MASTER RADIO
(MDS 9820 Shown)
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
HOST SYSTEM

4 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C

Simplex Peer-to-Peer

Peer-to-peer communication is possible using the transceivers simplex
mode. With this arrangement (Figure 4), two or more remote units can
share information by direct communication with each other in addition
to communicating with a central master radio. This is possible because
the transmit and receive frequencies for each hop channel are the same
at each radio when simplex mode is enabled. If adequate transmission
paths exist, each radio can communicate with all other units in the net-
work. Additional details for peer-to-peer systems are provided in
Section 4.2 (Page 19).

Invisible place holder

Figure 4. Typical simplex Peer-to-Peer Network

Peer-to-Peer with Repeater Assistance

Peer-to-peer communication is also possible using this alternate
arrangement (see Figure 5). It overcomes the range limitations of a sim-
plex peer-to-peer system by using a repeater to re-transmit the signals of
all stations in the network. The repeater consists of two radiosone pro-
grammed as a remote using master frequencies (

MODE R-M

command),
and the other programmed as a conventional master. Additional details
for peer-to-peer systems are given in Section 4.2 (Page 19).
RTU
RTU
PEER-TO-PEER
PEER-TO-PEER
RTU
RTU
REMOTE RADIO
MASTER RADIO
HOST SYSTEM
P
E
E
R
-
T
O
-
P
E
E
R
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO

MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 5

Invisible place holder

Figure 5. Typical Peer-to-Peer Network with Repeater Assistance

Point-to-Point System

A point-to-point configuration (Figure 6) is a simple arrangement con-
sisting of just two radiosa master and a remote. This provides a sim-
plex or half-duplex communications link for the transfer of data between
two locations.

Invisible place holder

Figure 6. Typical Point-to-Point Link

Tail-End Link (MAS Extension)

A tail-end link can be used to extend the range of a traditional (licensed)
MAS system. This might be required if an outlying site is blocked from
the MAS master station by a natural or man-made obstruction. In this
arrangement, an MDS 9810 radio links the outlying remote site into the
rest of a licensed MAS system by sending data from that site to an asso-
ciated MDS 9810 installed at one of the licensed remote sites. (See
Figure 7).
As the data from the outlying site is received at the licensed remote site,
it is transferred to the licensed radio (via a local cable connection) and
is then transmitted to the MAS master station in the usual manner. Addi-
tional details for tail-end links are given in Section 4.3 (Page 21).
RTU
REMOTE
HOST COMPUTER
RTU
RTU
REPEATER STATION
Pin 3 Pin 2
* Special operating mode.
See Programming section of manual.
REMOTE
REMOTE
REMOTE
REMOTE-MASTER*
MASTER
REMOTE RADIO
RTU MASTER RADIO
HOST
SYSTEM

6 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C

Invisible place holder

Figure 7. Typical Tail-End Link Arrangement

Repeater System

Traditional

Although the range between MDS 9810 radios is typically 10 to15 miles
over average terrain, it is possible to extend the range considerably by
connecting two units together at one site in a back-to-back fashion to
form a repeater, as shown in Figure 8. Additional details for repeater
systems are given in Section 4.4 (Page 22).

Invisible place holder

Figure 8. Typical Repeater System Configuration

Single-Radio Repeater

Alternative Method

A repeater may also be established using a

single

MDS x810 Trans-
ceiver. This type of repeater cannot operate in full-duplex mode as with
the traditional repeater described above. However, if a loss in transmis-
sion speed and efficiency can be tolerated, it may be a viable solution in
some systems.
P
O

N
T
-
T
O
-
P
O

N
T
S
P
R
E
A
D
S
P
E
C
T
R
U
M
L
N
K
REMOTE
RADO
MASTER
STATON
MAS SYSTEM (LICENSED OR UNLICENSED) MDS 9810/9820 LINK TO AN OUTLYING SITE
REPEATER
RTU
REMOTE
RADO
Null-Modem
Cable
RTU
RTU
MDS 9810/ 9820
MASTER RADO
MDS 9810/ 9820
REMOTE RADO
REMOTE
RADO
RTU
RTU
REPEATER LINK
Null-Modem Cable
RTU
MASTER
RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
MASTER
RADIO
HOST COMPUTER
P
O
IN
T
-T
O
-P
O
IN
T
L
IN
K
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 7
A single-radio repeater works similar to the system shown in Figure 8,
but consists of just one transceiver at the repeater site. It works by buff-
ering (storing) incoming messages and retransmitting them a short time
later. Accordingly, there will be a delay in transmissions through this
type of repeater. Additional details for Single-Radio repeater s are given
in Section 4.5 (Page 24).
2.3 Accessories
The transceiver can be used with one or more of the accessories listed in
Table 1. Contact the factory for ordering details.
3.0 INSTALLATION PLANNING
The installation of the radio is not difficult, but it does require some
planning to ensure station reliability and efficiency. This section pro-
vides tips for selecting an appropriate site, choosing an antenna system,
and reducing the chance of harmful interference.
3.1 General Requirements
There are three main requirements for installing the radioadequate
and stable primary power, a good antenna system, and the correct inter-
face between the transceiver and the data device.
Table 1. Accessories
Accessory Description MDS P/N
Power Supply
Kit
For powering the transceiver from an AC source. 01-3682A01
Hand-Held
Terminal Kit
(HHT)
Terminal that plugs into the radios RJ-11
DIAG(NOSTICS) connector. Allows radio
programming, diagnostics & control. Includes
carrying case, cable set and manual.
02-1501A01
RTU Simulator Test unit that simulates data from a remote
terminal unit. Comes with polling software that
runs on a PC. Useful for testing radio operation.
03-2512A01
Radio
Configuration
Software
Windows-based software that allows radio
programming and control using a PC. Includes
on-line instructions. (See Section 8.5 (Page 61)
for PC connection details.)
03-3156A01
Paging Filter Antenna system filter used to reduce RF
interference from paging transmitters operating
in the 905-915 MHz band.
20-2822A01
Paging Filter Antenna system filter used to reduce RF
interference from paging transmitters operating
in the 902-927 MHz band.
20-22822A02
EIA-232 to
EIA-422
Converter
External adapter that converts the radios DATA
INTERFACE connector to EIA-422 compatible
signaling. May be required for long cable runs
(over 50 feet/15 meters).
03-2358A01
8 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Figure 9 shows a typical remote station arrangement. At a remote sta-
tion, a directional antenna is normally used, and a Remote Terminal Unit
(RTU) or other telemetry equipment replaces the host computer nor-
mally used in a master station.
Invisible place holder
Figure 9. Typical Remote Station Arrangement
3.2 Site Selection
For a successful installation, careful thought must be given to selecting
proper sites for the master and remote stations. Suitable sites should pro-
vide:
Protection from direct weather exposure
A source of adequate and stable primary power
Suitable entrances for antenna, interface or other required
cabling
Antenna location that provides an unobstructed transmission
path in the direction of the associated station(s)
These requirements can be quickly determined in most cases. A possible
exception is the last itemverifying that an unobstructed transmission
path exists. Radio signals travel primarily by line-of-sight, and obstruc-
tions between the sending and receiving stations will affect system per-
formance. If you are not familiar with the effects of terrain and other
obstructions on radio transmission, the discussion below will provide
helpful background.
13.8 VDC
POWER
CABLE
13.8 VDC
POWER
SUPPLY
REMOTE TERMINAL
UNIT
ANTENNA SYSTEM
(Directional Type
Normally Used)
LOW-LOSS FEEDLINE
REMOTE RADIO
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 9
Terrain and Signal Strength
While the 900 MHz band offers many advantages over VHF and lower
UHF frequencies for data transmission, they are also more prone to
signal attenuation from obstructions such as terrain, foliage or buildings
in the transmission path.
A line-of-sight transmission path between the master station and its
associated remote site(s) is highly desirable and provides the most reli-
able communications link. A line-of-sight path can often be achieved by
mounting the station antenna on a tower or other elevated structure that
raises it to a level sufficient to clear surrounding terrain and other
obstructions.
The importance of a clear transmission path relates closely to the dis-
tance to be covered by the system. If the system is to cover only a limited
geographic area, say up to 3 miles (4.8 km), then some obstructions in
the transmission path can usually be tolerated with minimal impact. For
longer range systems, any substantial obstruction in the transmission
path could compromise the performance of the system, or block trans-
mission entirely.
Much depends on the minimum signal strength that can be tolerated in
a given system. Although the exact figure will differ from one system to
another, a Received Signal Strength Indication (RSSI) of 90 dBm or
stronger will provide acceptable performance in many systems. While
the equipment will work at lower signal strengths, this provides a fade
margin to account for variations in signal strength which may occur
from time-to-time. RSSI can be measured with a Hand-Held Terminal
connected to the remote radios DIAG(NOSTICS) connector. (See Section
6.0, beginning on Page 28.)
Conducting a Site Survey
If you are in doubt about the suitability of the radio sites in your system,
it is best to evaluate them before a permanent installation is begun. This
can be done with an on-the-air test (preferred method); or indirectly,
using path-study software.
An on-the-air test is preferred because it allows you to see firsthand the
factors involved at an installation site and to directly observe the quality
of system operation. Even if a computer path study was conducted ear-
lier, this test should be done to verify the predicted results.
The test can be performed by first installing a radio and antenna at the
proposed master station site and then visiting each remote site with a
transceiver and a hand-held antenna. (An RTU simulatorMDS Part
No. 03-2512A01can be connected to each radio in the network to sim-
ulate data during this test.)
10 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
With the hand-held antenna positioned near the proposed mounting
spot, a technician can check for synchronization with the master station
(shown by a lit SYNC lamp on the front panel) and measure the reported
RSSI value. If adequate signal strength cannot be obtained, it may be
necessary to mount the station antennas higher, use higher gain
antennas, or select a different site. To prepare the equipment for an
on-the-air test, follow the general installation procedures given in this
guide and become familiar with the operating instructions given in Sec-
tion 5.0, beginning on Page 26.
If time is short, and a site survey is impractical, a computer path study
is a good alternative. Factors such as terrain, distance, transmitter
power, receiver sensitivity, and other conditions are taken into account
to predict the performance of a proposed system. Contact MDS for more
information on path study services.
3.3 A Word About Radio Interference
The transceiver shares frequency spectrums with other services and
other Part 15 (unlicensed) devices in the USA. As such, near 100% error
free communications may not be achieved in a given location, and some
level of interference should be expected. However, the radios flexible
design and hopping techniques should allow adequate performance as
long as care is taken in choosing station location, configuration of radio
parameters and software/protocol techniques.
In general, keep the following points in mind when setting up your com-
munications network:
1. Systems installed in rural areas are least likely to encounter
interference; those in suburban and urban environments are more
likely to be affected by other devices operating in the license-free
frequency band and by adjacent licensed services.
2. If possible, use a directional antenna at remote sites. Although these
antennas may be more costly than omnidirectional types, they con-
ne the transmission and reception pattern to a comparatively nar-
row lobe, which minimizes interference to (and from) stations
located outside the pattern. (The use of a directional antenna may
not be possible in a simplex peer-to-peer network, where all remotes
are designed to communicate with one another.)
3. If interference is suspected from a nearby licensed system (such as a
paging transmitter), it may be helpful to use horizontal polarization
of all antennas in the network. Because most other services use ver-
tical polarization in this band, an additional 20 dB of attenuation to
interference can be achieved by using horizontal polarization.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 11
4. Multiple MDS 9810 systems can co-exist in proximity to each other
with only very minor interference as long as they are each assigned
a unique network address. Each network address has a different hop
pattern.
5. If constant interference is present in a particular frequency zone, it
may be necessary to lock out that zone from the radios hopping
pattern. The radio includes built-in software to help users identify
and remove blocked frequency zones from its hopping pattern. Refer
to the discussion of ZONE DATA (Page 49) and SKIP (Page 46) com-
mands for more information.
6. If interference problems persist even after removing blocked zones,
try reducing the length of data streams. Groups of short data streams
have a better chance of getting through in the presence of interfer-
ence than do long streams.
7. The power output of all radios in a system should be set for the low-
est level necessary for reliable communications. This lessens the
chance of causing unnecessary interference to nearby systems.
3.4 Antenna & Feedline Selection
Antennas
The equipment can be used with a number of antennas. The exact style
used depends on the physical size and layout of a system. Contact your
MDS representative for specific recommendations on antenna types and
hardware sources.
In general, an omnidirectional antenna (Figure 10) is used at the master
station site in an MAS system. This provides equal coverage to all of the
remote sites.
NOTE: Antenna polarization is important. If the wrong polarization is
used, a signal reduction of 20 dB or more will result. Most
systems using a gain-type omnidirectional antenna at the
master station employ vertical polarization of the signal; there-
fore, the remote antenna(s) must also be vertically polarized
(elements oriented perpendicular to the horizon).
When required, horizontally polarized omnidirectional
antennas are also available. Contact your MDS representative
for details.
12 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Invisible place holder
Figure 10. Typical Omnidirectional Antenna
At remote sites and point-to-point systems, a directional antenna, such
as a Yagi is generally recommended to minimize interference to and
from other users. Antennas are available from a number of manufac-
turers.
Invisible place holder
Figure 11. Typical Yagi Antenna (mounted to mast)
Feedlines
The choice of feedline used with the antenna should be carefully consid-
ered. Poor-quality coaxial cables should be avoided, as they will
degrade system performance for both transmission and reception. The
cable should be kept as short as possible to minimize signal loss.
For cable runs of less than 20 feet (6 meters), or for short range trans-
mission, an inexpensive type such as Type RG8A/U may be acceptable.
Otherwise, we recommend using a low-loss cable type suited for 900
MHz, such as Heliax

.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 13
Table 2 lists several types of feedlines and indicates the signal losses (in
dB) that result when using various lengths of each cable at 900 MHz.
The choice of cable will depend on the required length, cost consider-
ations, and the amount of signal loss that can be tolerated.
3.5 How Much Output Power Can be Used?
The transceiver is normally supplied from the factory set for a nominal
+30 dBm (1 Watt) RF power output setting; this is the maximum trans-
mitter output power allowed under FCC/IC rules. The power must be
decreased from this level if the antenna system gain exceeds 6 dBm. The
allowable level is dependent on the antenna gain, feedline loss, and the
transmitter output power setting. Power considerations for various
antenna systems are discussed below.
NOTE: In some countries, the maximum allowable RF output may be
limited to less than 1 watt (e.g., 100 mW /+20 dBm). Be sure
to check for and comply with the requirements for your area.
Transmitter Power vs. Antenna System Gain
To determine the maximum allowable power setting of the radio, follow
the steps below. It is imperative that professional system planning
include cable loss or attenuators to ensure that the FCC/IC limit of 36
dBm EIRP is not exceeded under any circumstances.
1. Determine the antenna system gain by subtracting the feedline loss
(in dB) from the antenna gain (in dBi). For example, if the antenna
gain is 9.5 dBi, and the feedline loss is 1.5 dB, the antenna system
gain would be 8 dB. (If the antenna system gain is 6 dB or less, no
power adjustment is required.)
2. Subtract the antenna system gain from 36 dBm (the maximum
allowable EIRP). The result indicates the maximum transmitter
power (in dBm) allowed under the rules. In the example above, this
is 28 dBm.
Table 2. Length vs. Loss in Coaxial Cables at 900 MHz
Cable Type
10 Feet
(3.05 Meters)
50 Feet
(15.24 Meters)
100 Feet
(30.48 Meters)
500 Feet
(152.4 Meters)
RG-8A/U 0.85 dB 4.27 dB 8.54 dB 42.70 dB
1/2 inch HELIAX 0.23 dB 1.15 dB 2.29 dB 11.45 dB
7/8 inch HELIAX 0.13 dB 0.64 dB 1.28 dB 6.40 dB
1 1/4 inch HELIAX 0.10 dB 0.48 dB 0.95 dB 4.75 dB
1 5/8 inch HELIAX 0.08 dB 0.40 dB 0.80 dB 4.00 dB
T
h
e
m
a
xim
u
m

E
IR
P
a
llow
e
d
u
n
d
e
r
F
C
C
/IC
ru
le
s is +
3
6

d
B
m
. F
o
llow
th
is
se
ctio
n
ca
re
fu
lly to

e
n
su
re
co
m
p
lia
n
ce.
IM
P
O
R
T
A
N
T
14 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
3. If the maximum transmitter power allowed is less than 30 dBm, use
the PWR command (described on Page 42) to set the power accord-
ingly.
For convenience, Table 3 lists several antenna system gains and shows
the maximum allowable power setting of the radio. Note that a gain of
6 dB or less entitles you to operate the radio at full power output30
dBm (1 watt).
* Many antenna manufacturers rate antenna gain in dBd in their
literature. To convert to dBi, add 2.15 dB.
Feedline loss varies by cable type and length. To determine the
loss for common lengths of feedline, see Table 2 on Page 13.
4.0 INSTALLATION
Figure 12 shows a typical transceiver product shipment, along with an
optional Hand-Held Terminal (HHT). Check the contents against the
packing list secured to the outside of the shipping box. Accessories and
spare parts kits, if any, are wrapped separately. Inspect all items for
signs of damage and save all packing materials for possible re-shipment.
Table 3. Antenna System Gain vs. Power Output Setting (USA)
Antenna System Gain
(Antenna Gain in dBi*
minus Feedline Loss in dB)
Maximum Power
Setting
(in dBm)
EIRP
(in dBi
6 (or less) 30 36
7 29 36
8 28 36
10 26 36
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 15
Invisible place holder
Figure 12. Typical Transceiver Shipment
Below are the basic steps for installing the transceiver. In most cases,
these steps alone will be sufficient to complete the installation. Should
further information be required, contact the factory at the number given
on the inside back cover of this manual.
If you are installing a peer-to-peer, tail-end link or repeater system, you
should also review Sections 4.2 (Page 19) and 4.3 (Page 21) for impor-
tant details on antennas, cabling and software settings.
NOTE: It is recommended that the master station be installed first. In
this way, it will be possible to quickly check the operation of
each associated remote station as it is placed on the air.
4.1 Transceiver Installation
1. Mount the transceiver to a stable surface using the brackets supplied
with the radio. (Fasteners/anchors are not supplied.) Figure 13
shows the dimensions of the transceiver case and its mounting
bracket. If possible, choose a mounting location that provides easy
access to the connectors on the end of the radio and an unobstructed
view of the LED status indicators.
INSTALLATION &
OPERATION GUIDE
13.8 VDC
POWER CABLE
HAND-HELD
TERMINAL
(OPTIONAL)
A
F1 B
F2 C
F3 D
F4 E
F5
F
G
H
1 I
2 J
3
K
L
M
4 N
5 O
6
P
Q
R
7 S
8 T
9
U
V
W
X
0 Y
.
Z
CTRL
ESC
BKSP
SPACE
ENTER
SHIFT
/
(
*
)

#
+
,
=
TRANSCEIVER
16 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Invisible place holder
Figure 13. Transceiver Mounting Dimensions
The screws holding the brackets to the radio are
5
16 inch (8 mm). If
replacement screws are used for any reason, they must not exceed
this length to avoid damage to the radios PC board.
2. Install the antenna and antenna feedline for the station. Antennas
should be mounted in the clear and in accordance with the manufac-
turers instructions.
Additional information on antennas and feedlines is contained in
Section 3.4 (Page 11).
NOTE: Strong fields near the antenna can interfere with the operation
of the low level RTU circuits and change the reported values
of the data being monitored. For this reason, the antenna
should be mounted at least 10 feet (>3 meters) from the radio,
RTU, sensors and other components of the system.
3. Connect the data equipment to the transceivers DATA INTERFACE
connector. Use only the required pins for the applicationDo not
use a fully pinned (25 conductor) cable. Typical applications require
the use of Pin 2 (transmit dataTXD), Pin 3 (received dataRXD)
1
.
7
5
"
4
.
4
4

C
M
Alternate
Position
2.25"
57 mm
2.0"
50 mm
6.63"
168 mm
8.5"
216 mm
5.625"
143 mm
7
.
2
5
"
1
8
4

m
m
2
.
7
5
"
7
0

m
m
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 17
and Pin 7 (signal ground). Figure 14 shows a detailed view of the
DATA INTERFACE connector.
If hardware ow control is desired, Pin 4 (request to sendRTS)
and Pin 5 (Clear-to-SendCTS) are also required. A detailed chart
of pin functions is provided in Table 15 on Page 59.
Invisible place holder
Figure 14. Transceiver Interface Connector Pins
(As viewed from outside the radio)
NOTE: The data cabling between the transceiver and the connected
device should be kept as short as possible. Cable runs over 50
feet (15 meters) may require the use of EIA-422 signaling.
Consult the factory for details.
4. Measure and install the primary power for the transceiver. It must be
within 10.530 Vdc* and be capable of furnishing up to 500 mA. Be
sure to observe proper polarity. The red wire on the power cable is
the positive lead; the black is negative.
* Transceivers shipped prior to Revision U (November 1999) may be
configured for 25 Vdc maximum DC input voltage.
NOTE: The radio is designed for use only in negative ground systems.
Additionally, the chassis must be bonded to an Earth ground,
either directly, through its mounting bracket, or via the antenna
system ground (coaxial shield). The radio may be damaged if
the chassis is not properly grounded per this recommendation.
Radios damaged in this way will not be covered under
warranty.
The power supply used with the transceiver should be equipped
with overload protection (NEC Class 2 rating), to protect against a
short circuit between its output terminals and the transceiver power
connector.
5. Set the radios conguration using a Hand-Held Terminal (HHT).
Review Section 6.0, PROGRAMMING (beginning on Page 28), if
you are unfamiliar with connecting and using the HHT.
Unused
Radio Inhibit (Sleep)
Unused
13
12
11
10
9
8
7
6
5
4
3
2
1
Receiver Unsquelched Sensor
Unused
Data Carrier Detect (DCD)
Signal Ground*
Data Set Ready (DSR)
Clear-to-Send Output (CTS)
Request-to-Send Input (RTS)
Received Data (RXD)*
Transmitted Data (TXD)*
Protective Ground
25
24
23
22
21
20
19
18
17
16
15
14
Alarm Output
Analog Input Pin
Diagnostic Channel Enable
RSSI Voltage
9.9 Vdc Regulated Output
Unregulated DC Input/Output
Digital Output Pin
Unused
Unused
Unused
Pin
Description
Pin
No.
Pin
No.
Pin
Description
Unused
Future use do not connect
* Required in most installations
18 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
The three essential settings for the transceiver are:
ModeMaster or Remote
Network Addressa unique number from 165000
Data Interface Parametersbps, data bits, parity, stop bits
a. Connect an HHT to the DIAG(NOSTICS) connector (see
Figure 15). After the HHT beeps, press to display the
ready > prompt.
b. Set the ModeDetermine whether the transceiver will be used
as a master or remote, and program it accordingly using the
MODE M or MODE R command (Page 41). (MODE M = Master,
MODE R = Remote.) Press . The HHT will display PRO-
GRAMMED OK.
NOTE: Transceivers are normally shipped from the factory
pre-configured as remotes. A master must be specifically
programmed using the MODE M command.
Invisible place holder
Figure 15. HHT Connected to Transceiver
c. Program the network addressType ADDR (Page 36) followed
by , , and then the desired address number
(165000). Press . All radios in a given system must be
programmed with the same network address. After programming
the address, PROGRAMMED OK will be displayed.
NOTE: It is strongly recommended that the last four digits of the
master radios serial number be used as the network address.
In this way, it is unlikely that two systems will have the same
address.
ENTER
ENTER
ANTENNA 13.8 VDC +
Z
CTRL
U
+

K
*
F
/
A
F1
V
,
Q
#
)
G
(
B
F2
SHIFT
ESC
W
=
R
7
M
4
H
1
C
F3
BKSP
X
0
S
8
N
5
I
2
D
F4
SPACE
Y
T
9
O
6
3
E
F5
ENTER
J
L
P
SPACE SHIFT
ENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 19
d. Set the data interface parameters to match the connected data
deviceThe default setting is 4800 baud, 8 data bits, no parity, 1
stop bit. If your data equipment requires a different setting, use
the BAUD xxxxx abc command (Page 36), where xxxxx equals the
baud rate (1200, 2400, 4800, 9600, 19200, or 38400 bps) and abc
indicates the control bits as follows:
a = Data bits (7 or 8)
b = Parity (N for None, O for Odd, E for Even)
c = Stop bits (1 or 2)
Using this scheme, a sample entry for the BAUD xxxxx abc com-
mand would look like this: BAUD 4800 8N1 (A similar example
using a five-character baud rate would appear as follows: BAUD
19200 8N1)
Press . After setting the data parameters, PROGRAMMED
OK will be displayed.
NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and are
not supported by the transceiver.
e. Record the Mode, Network Address, and Baud Rate settings on
a label and afx it to the transceiver cover.
6. Repeat the above steps for each transceiver in the network.
This completes the basic installation of the transceiver. Section 5.1, Ini-
tial Start-up (beginning on Page 26), contains steps for evaluating radio
performance.
4.2 Peer-to-Peer Systems
Peer-to-peer systems allow remote radios to communicate with each
other as well as with the master station. The paragraphs below describe
two types of peer-to-peer systemssimplex and repeater assisted.
Simplex Peer-to-Peer
A simplex peer-to-peer system is one in which all radios use the same
transmit and receive frequencies. This is also known as single-frequency
operation. A simplex arrangement is the simplest configuration for
peer-to-peer systems, but it usually has limited transmission range
because of the need for all stations to use omnidirectional antennas. (If
range is a concern, see Peer-to-Peer with Repeater Assistance on page
20.)
With a simplex peer-to-peer system, there are three key items to
remember:
Programming To program a system for simplex operation, the master radio must
be set to SIMPLEX ON (Page 45). This setting is automatically
ENTER
20 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
applied to all remote radios as soon as they become synchronized
with the master radio.
Antennas Omnidirectional antennas are normally required at all stations in a
simplex system. The transmission range may be signicantly
reduced as compared with stations using directional antennas, so it
is especially important that sites be chosen to allow sufcient signal
strength between all units. A discussion of site selection is provided
in Section 3.2.
Data Collision
Avoidance
One drawback with peer-to-peer systems is the risk of data colli-
sions that can occur through self-interference. This problem can be
alleviated with data protocols (such as Harris DNP3) which use
Carrier Sense Multiple Access (CSMA) to detect a busy channel. In
these systems, Pin 10 (Receiver Unsquelched-RUS) on the trans-
ceiver should be connected to the RTUs Data Carrier Detect
(DCD) pin.
Peer-to-Peer with Repeater Assistance
A shortcoming of a simplex peer-to-peer network is that communication
range is often reduced because of the need for all stations to use omni-
directional antennas. An alternative peer-to-peer network can be estab-
lished using a repeater station to re-transmit the signals of all stations in
the network. (See Figure 16.) Because directional antennas (aimed at the
repeater site) can be used at all remote sites, the communication range
of the system is greatly increased. Like a simplex peer-to-peer system,
each remote station can hear the transmissions of the others so that
data collisions can be avoided.
Invisible place holder
Figure 16. Peer-to-Peer Network with Repeater Assistance
Here are some specific requirements for peer-to-peer systems with
repeater assistance:
Repeater Setup The repeater station in a peer-to peer network consists of two
co-located transceiversone programmed as a remote using master
MASTER
REMOTE-MASTER
RTU
REMOTE
REMOTE
HOST
COMPUTER
RTU
REMOTE
RTU
REMOTE
REPEA
STATION
TER
Pin 3 Pin 2
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 21
frequencies (MODE R-M command, Page 41), and the other pro-
grammed as a master (MODE M command).
Interface Wiring Pin 2 (TXD) of the master radio must be connected to Pin 3 (RXD)
of the other radio (the one programmed as MODE R-M) using a local
interface cable. This allows the signals received by the MODE R-M
radio to be re-transmitted by the master. The signal ground leads
(Pin 7) must also be connected to each other.
Invisible place holder
Figure 17. Data Interface Cable Wiring
for Peer-to-Peer Systems with Repeater Assistance
Antennas Two omnidirectional antennas are required at peer-to-peer repeater
stationsone for each radio. It is important to minimize coupling
between these antennas. The necessary isolation can be achieved by
vertical separation. In this arrangement, one antenna is mounted
directly over the other, separated by at least 10 feet (3.2 Meters).
This takes advantage of the minimal radiation exhibited by verti-
cally polarized antennas directly above and below one another.
Full-Duplex
Configuration
The paragraphs above discuss the requirements for a basic Repeater
Assisted Peer-to-Peer system. If a full-duplex system is required
(with the SCADA host computer located at the repeater), additional
considerations apply. If you are constructing this type of system,
contact the factory and request a copy of Application Bulletin
97002. The bulletin can also be found at www.microwavedata.com.
4.3 Tail-End Links
A tail-end link is established by connecting the radio back-to-back
with another radio such as a licensed MDS 2300/4300 series transceiver.
This can be used to link an outlying remote site into the rest of an MAS
network. Here are some specific requirements for tail-end link systems:
Interface Wiring
The connection between the two radios in a tail-end link system
must be made as shown in Figure 18.
DB-25 DB-25
M
a
s
t
e
r
(
M
o
d
e

M
3
2
7
2
3
7
R
e
m
o
t
e

M
a
s
t
e
r
(
M
o
d
e

R
-
M
)
RXD
TXD
GND
TXD
RXD
GND
22 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Invisible place holder
Figure 18. Data Interface Cable Wiring for Tail-End Links
Programming
In a tail-end link system, the radios device behavior must be set to
DEVICE CTS KEY (Page 38) using the HHT. This allows one radio to
control the keying of another. Also, the CTS delay time must be set
(using the CTS xxx command, Page 37) to the time required for the
other transceiver to key up. This time is typically 10 ms for MDS
2000/4000 series transceivers.
4.4 RepeatersTraditional Method
Two MDS 9810 radios (or another MDS spread spectrum radio) may be
connected back-to-back using a null-modem cable to form a repeater
station. This is sometimes required in a network that includes a distant
remote station that would otherwise be unable to communicate with the
master station due to distance or terrain.
A repeater works by re-transmitting data from the outlying remote site
to the master station and vice versa. It introduces a small amount of
end-to-end transmission delay, but this is not a problem in most systems.
The geographic location of a repeater station is especially important. A
site must be chosen that allows good communication with both the
master and the outlying remote site. This is often on top of a hill, or other
elevated terrain from which both sites can be seen by the repeater sta-
tion antennas. A detailed discussion on the effects of terrain is given in
Section 3.2, Site Selection (beginning on Page 8).
The following paragraphs contain specific requirements for repeater
systems.
DB-25 DB-25
M
D
S

2
0
0
0
/
4
0
0
0

S
e
r
i
e
s

X
C
V
R
(
o
r

d
e
v
i
c
e

r
e
q
u
i
r
i
n
g

k
e
y
l
i
n
e
)
2
3
7
3
2
7
M
D
S

S
p
r
e
a
d

S
p
e
c
t
r
u
m

R
e
m
o
t
e

X
C
V
R

(
D
E
V
I
C
E

C
T
S

K
E
Y
)
TXD
RXD
GND
RXD
TXD
GND
5 4 CTS RTS
Keyline
DCE DCE
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 23
Antennas
Two antennas are required at repeater stationsone for each radio.
Measures must be taken to minimize the chance of interference between
these antennas. One effective technique for limiting interference is to
employ vertical separation. In this arrangement, one antenna is
mounted directly over the other, separated by at least 10 feet (3 Meters).
This takes advantage of the minimal radiation exhibited by most
antennas directly above and below their driven elements.
Another interference reduction technique is to cross-polarize the
repeater antennas. If one antenna is mounted in the vertical plane, and
the other in the horizontal plane, an additional 20 dB of attenuation can
be achieved. (Remember that the corresponding stations must use the
same antenna orientation when cross-polarization is used.)
System Addresses
The two radios that are wired together at the repeater site must have dif-
ferent system addresses. To set or view the system address, see ADDR
[1...65000] on page 36.
Interface Wiring
A null-modem cable (Figure 19) is required between the DATA INTER-
FACE connectors of the two radios forming a repeater station. This
allows them to freely exchange data even though they are both config-
ured as DCE devices.
Invisible place holder
Figure 19. Data Interface Cable Wiring for Null-Modem Cable
(used for traditional repeater)
Diagnostic Limitations
As of the date of publication, over-the-air diagnostics is not fully sup-
ported in repeater systems. Diagnostic data from these systems may be
unavailable or unreliable. This is particularly true if a repeater radio is
configured as the root in a diagnostics scheme (See Performing Net-
work-Wide Remote Diagnostics on Page 53.) Better success might be
achieved by picking a standard remote to use as the root.
DB-25 DB-25
S
p
r
e
a
d

S
p
e
c
t
r
u
m

M
a
s
t
e
r
(
D
C
E
)
2
3
7
3
2
7
S
p
r
e
a
d

S
p
e
c
t
r
u
m

R
e
m
o
t
e
(
D
C
E
)
TXD
RXD
GND
RXD
TXD
GND
24 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
4.5 Single-Radio RepeaterAlternative Method
A single MDS x810 transceiver may be used to form a repeater station
to extend the range of a system. The general repeater principles dis-
cussed in Section 4.4 apply to single-radio repeaterswhy repeaters are
used, geographic site considerations, etc. However, there are some
important differences in single-radio repeater systems:
Only one transceiver is used at the repeater site.
The transceivers TXD & RXD pins must be tied together (DB-25).
There may be considerable delay through the repeater, because the
radio buffers (stores) incoming data and retransmits it a short time
later.
The paragraphs that follow contain specific requirements for
single-radio repeater systems.
Interface Wiring
A single-radio repeater is formed by connecting TXD (Pin 2) and RXD
(Pin 3) on the DATA INTERFACE connector together as shown in
Figure 20.
Invisible place holder
Figure 20. Data Interface Cable Wiring for Single-Radio Repeater
Software Programming (TDD Command)
As with other repeater systems, the network must be configured for
TDD operation by programming the master radio with TDD ON. This
places the DATA INTERFACE port in time division duplex (sometimes
called simulated full-duplex) mode.
Although a single radio can never actually transmit and receive RF data
at the same time, the TDD ON command enables the radio to simulate
full-duplex at the data port, by designating alternate channel hops as
transmit or receive hops, and buffering data when transmission is not
permitted.
DB-25
DATA INTERFACE
CONNECTOR
2
3
TXD
RXD
Pins 2 & 3
Connected Together
for Single-Radio Repeater
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 25
Limitations of Single-Radio Repeaters
Diagnostics As of the date of publication, over-the-air diagnostics is not fully sup-
ported in repeater systems. Diagnostic data from these systems may be
unavailable or unreliable. This is particularly true if a repeater radio is
configured as the root in a diagnostics scheme (See Performing Net-
work-Wide Remote Diagnostics on Page 53.) Better success might be
achieved by picking a standard remote to use as the root.
Data Throughput
Delay
When TDD is set to ON, there will be a significant delay in data
throughput and an increase in latency (see Glossary of Terms). In gen-
eral, the data throughput will be cut in half, and worst case latency will
increased by two hoptimes.
4.6 Using the Radios Sleep Mode
In some installations, such as at solar-powered sites, it may be necessary
to keep the transceivers power consumption to an absolute minimum.
This can be accomplished using Sleep Mode. In this mode, power con-
sumption is reduced to less than 30 milliamperes.
Sleep Mode can be enabled under RTU control by asserting a ground (or
EIA-232 low) on Pin 12 of the radios DATA INTERFACE connector. The
radio stays in Sleep Mode until the low is removed, and all normal func-
tions are suspended. As a status indication, the radios PWR LED flashes
once every four seconds to indicate that it is in Sleep Mode.
The radio can be woken up by your RTU every minute or so to verify
synchronization with the master station. When Pin 12 is opened (or an
EIA-232 high is asserted), the radio will be ready to receive data within
75 milliseconds.
It is important to note that power consumption will increase signifi-
cantly as communication from the master station degrades. This is
because the radio will spend a greater period of time awake, looking
for synchronization messages from the master radio.
Sleep Mode Example
The following example describes Sleep Mode implementation in a typ-
ical system. Using this information, you should be able to configure a
system that meets your own particular needs.
Suppose you need communications to each remote site only once
per hour. Program the RTU to raise an EIA-232 line once each hour
(DTR for example) and wait for a poll and response before lower-
ing it again. Connect this line to Pin 12 of the radios DATA INTER-
FACE connector. This will allow each RTU to be polled once per
hour, with a signicant savings in power consumption.
26 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
5.0 OPERATION
5.1 Initial Start-up
In-service operation of the transceiver is completely automatic. Once
the unit has been properly installed and configured, operator actions are
limited to observing the LED status indicators for proper operation.
If all parameters are correctly set, operation of the radio can be started
by following these steps:
1. Apply primary power to the radio.
2. Observe the transceiver LED status panel (Figure 21) for the proper
indications. Table 4 provides a complete explanation of the LED
functions.
In a normally operating system, the following LED indications will
be seen within 16 seconds of start-up:
PWR lamp lit continuously
SYNC lamp lit continuously
Remote radio(s) transmitting data (TXD) and receiving data
(RXD) with the master station
Invisible place holder
Figure 21. LED Status Indicators
5.2 Performance Optimization
After the basic operation of the radio has been checked, you may wish
to optimize its performance using some of the suggestions given here.
The effectiveness of these techniques will vary with the design of your
system and the format of the data being sent.
PWR SYNC TXD RXD
Table 4. LED Status Indicators
LED Name Description
PWR ContinuousPower is applied to the radio; no problems detected.
Flashing 5 times per secondFault indication.
See Section 7.0, TROUBLESHOOTING (beginning on Page 50).
Flashing once every 4 secondsradio is in Sleep mode.
SYNC Lights continuously to indicate the radio is receiving/sending
synchronization frames. Within 16 seconds of power-up, this LED
should be lit continuously.
TXD Indicates EIA-232 space (logic high) signal input to the DB-25
connector.
RXD Indicates EIA-232 space (logic high) signal output from the DB-25
connector.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 27
Complete instructions for using the software commands referenced
herein are provided in Section 6.0, PROGRAMMING (beginning on
Page 28).
Antenna Aiming
For optimum performance of directional antennas, they must be accu-
rately aimed in the direction of desired transmission. The easiest way to
do this is to point the antenna in the approximate direction, then use the
remote radios built-in Received Signal Strength Indication (RSSI) fea-
ture to further refine the heading for maximum received signal strength.
RSSI can be read by connecting an HHT to the remote radios RJ-11
DIAG(NOSTICS) jack and entering the RSSI command. Instructions on
connecting and using an HHT are given in Section 6.0, PROGRAM-
MING (beginning on Page 28).
In an MAS system, RSSI readings are only meaningful when initiated
from a remote station. This is because the master station typically
receives signals from several remote sites, and the RSSI would be con-
tinually changing as the master receives from each remote in turn.
Antenna SWR Check
It is necessary to briefly key the transmitter for this check by placing the
radio in the SETUP mode (Page 44) and using the KEY command on the
HHT. (To unkey the radio, enter DKEY; to disable the setup mode and
return the radio to normal operation, enter Q or QUIT.)
The SWR of the antenna system should be checked before the radio is
put into regular service. For accurate readings, a wattmeter suited for
1000 MHz is required. One unit meeting this criteria is the Bird Model
43

directional wattmeter with an 5J element installed.


The reflected power should be less than 10% of the forward power (2:1
SWR). Higher readings usually indicate problems with the antenna,
feedline or coaxial connectors.
Data Buffer Setting
The default setting for the data buffer is ON to accommodate virtually
any data format. However, if the system can operate satisfactorily with
the buffer OFF, we recommend doing so using the BUFF OFF command
(Page 37). This allows the radio to operate with the lowest possible
latency and improves channel efficiency.
Hoptime Setting
The default hop time setting is HOPTIME NORMAL. If message sizes typi-
cally exceed 256 bytes, channel efficiency can be improved by setting
this parameter to HOPTIME LONG.
28 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
A detailed explanation of the HOPTIME command, and a table listing the
available selections and the channel efficiency associated with each, can
be found on Page 40.
Baud Rate Setting
The default baud rate setting is 4800 bps to accommodate most systems.
If your system will support a higher data rate, you should increase the
radios transmission speed using the BAUD xxxxx abc command (Page
37). It should be set to the highest speed that can be sent by the data
equipment in the system. (The transceiver supports 1200 to 38400 bps)
Radio Interference Checks
The ZONE DATA command (Page 49) can be used to check for interfer-
ence in the radios eight frequency zones. If interference is found in one
or more of these zones, the SKIP command (Page 46) can be used to omit
them from the hop pattern. You should also review Section 3.3, A Word
About Radio Interference (beginning on Page 10), when dealing with
interference problems.
6.0 PROGRAMMING
There are no manual adjustments on the transceiver. Programming and
control is performed remotely, using one of these methods:
MDS Hand-Held Terminal (P/N 02-1501A01)
MDS Radio Conguration Software (P/N 03-3156A01)
MDS Network Management Software
This manual describes control of the radio using the Hand-Held Ter-
minal (HHT). Instructions for using the other methods are contained in
their respective user manuals or on-line documentation.
6.1 Hand-Held Terminal Connection & Start-up
This section gives basic information for connecting and using the MDS
Hand-Held Terminal for control of the radio. For more information
about the terminal, see the instructions supplied with each HHT kit.
The steps below assume that the HHT has been configured for use with
the transceiver (80 character screen display). If the HHT was previously
used with a different model transceiver, or if its default settings have
been changed, refer to Section 6.2 for setup details.
1. Connect the HHTs coiled cord to the DIAG(NOSTICS) (RJ-11) jack
on the radio as shown in Figure 22. This automatically places the
radio into the control and programming mode.
As an alternative, the DATA INTERFACE (DB-25) connector may be
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 29
used for programming instead of the DIAG(NOSTICS) jack. With this
arrangement, Pin 23 of the HHT cable must be grounded to enable
the diagnostic channel. (See Table 15 on Page 59.)
Invisible place holder
Figure 22. Hand-Held Terminal Connected to the Transceiver
2. When the HHT is connected, it runs through a brief self-check, end-
ing with a beep. After the beep, press to receive the ready
> prompt.
6.2 Hand-Held Terminal Setup
The following is a set of instructions for re-initializing an HHT for use
with the transceiver. These steps may be required if the HHT was previ-
ously used with a different radio, or if the HHT default settings have
been inadvertently altered.
1. Plug the HHT into the DIAG(NOSTICS) connector. Enable the setup
mode by pressing the , and keys in sequence.
The display shown in Figure 23 will appear.
ANTENNA 13.8 VDC +
Z
CTRL
U
+

K
*
F
/
A
F1
V
,
Q
#
)
G
(
B
F2
SHIFT
ESC
W
=
R
7
M
4
H
1
C
F3
BKSP
X
0
S
8
N
5
I
2
D
F4
SPACE
Y
T
9
O
6
3
E
F5
ENTER
J
L
P
ENTER
SHIFT CTRL SPACE
30 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Invisible place holder
Figure 23. HHT setup display
2. The rst of 15 menu items will be displayed. Settings can be
reviewed by pressing the NEXT function ( key). Parameter set-
tings can be changed by pressing the ROLL function ( key).
3. Set up the HHT as listed in Table 5.
4. Exit the HHT setup mode by pressing for Exit, or by pressing the
(Roll) key after the nal menu item has been reviewed.
6.3 Keyboard Commands
Table 6 is a reference chart of software commands for the transceiver.
See Section 6.4 for detailed command descriptions.
Entering Commands
The proper procedure for entering commands is to type the command,
followed by an keystroke. For programming commands, the
command is followed by and the appropriate information or
values, then .
ZE
A
Table 5. HHT Operational Settings
Parameter Setting Parameter Setting
Re-init HT NO Scroll On 33rd
Baud Rate= 1200 Cursor ON
Comm bits= 8,1,n CRLF for CR OFF
Parity Error OFF Self Test SLOW
Key Repeat OFF Key Beep ON
Echo OFF Screen Size 80
Shift Keys YES Menu Mode LONG
Ctl Chars PROCS
C
A
ENTER
SPACE
ENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 31
Here are some additional points to remember when using the HHT:
Use the key to access numbers; press again to return let-
ters.
Flashing square cursor ( ) denotes letter mode.
Flashing superscript rectangular cursor ( ) denotes number
mode.
Use key to edit information or commands being typed
into the terminal.
Error Messages
Below are some HHT error messages you may encounter and their prob-
able causes:
UNKNOWN COMMANDCommand was not recognized.
INCORRECT ENTRYCommand format or its arguments invalid.
COMMAND FAILEDCommand was unable to complete success-
fully. Possible software problem.
NOT PROGRAMMEDSoftware was unable to program the
EEPROM or the requested display item was not programmed.
TEXT TOO LONGResponse to OWN or OWM command when too
many characters have been entered.
NOT AVAILABLEThe entered command or parameter was valid,
but it referred to a currently unavailable choice.
PASSWORD INVALIDThe entered password was invalid, and
was not accepted.
ACCESS DENIEDCommand is invalid for current password
level.
EPROM FAILUREThe INIT command cannot write to the radios
EEPROM.
SHIFT
ESC/BKSP
32 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Table 6. Command Summary
COMMAND DESCRIPTION
N
E
T
W
O
R
K
C
O
N
F
I
G
U
R
A
T
I
O
N
T
h
e
s
e

p
r
o
g
r
a
m
m
i
n
g

c
o
m
m
a
n
d
s
c
a
n

o
n
l
y

b
e

s
e
t

a
t

t
h
e

m
a
s
t
e
r

r
a
d
i
o
.
BUFF [ON, OFF]
Details Page 37
ON = Seamless data, OFF = Fast byte through-
put.
HOPTIME [XSHORT, 16, 20,
25, 32, SHORT, NORMAL,
LONG]
Details Page 40
Select hop timeXSHORT, 16 ms, 20 ms, 25
ms, 32 ms, SHORT, NORMAL, LONG
SEND [n, -n, +n]
Details Page 43
Sets/displays re-send count for data packets.
Useful in areas with heavy radio interference.
SIMPLEX [ON, OFF]
Details Page 45
Program simplex/half-duplex selection.
ON = simplex, OFF = half-duplex
SKIP [NONE, 1...8]
Details Page 46
Select combination of frequency operating
zones to avoid.
SKIPSYNC [ON/OFF]
Details Page 46
May be used to suppress transmission of
SYNC messages in skipped zones. (See also
SKIP command). Default setting is OFF.
TDD [ON/OFF]
Details Page 47
Sets or displays time-division multiplex status of
DATA INTERFACE connector. (Sometimes
referred to as simulated full-duplex mode.)
N
E
T
W
O
R
K
-
W
I
D
E
D
I
A
G
N
O
S
T
I
C
S
C
O
N
F
I
G
U
R
A
T
I
O
N
DLINK [xxxxx]
Details Page 39
Set baud rate of diagnostics link
DTYPE
[NODE/ROOT/GATE/PEER]
Details Page 39
Set radios operational characteristics for net-
work-wide diagnostics
UNIT [1000065000]
Details Page 48
Program unit address. Used to set a unique
address for network-wide diagnostics.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 33
S
E
T
/
P
R
O
G
R
A
M

C
O
M
M
A
N
D
S
ADDR [1...65000]
Details Page 36
Program network address
AMASK [0000 0000FFFF
FFFF]
Details Page 36
Sets alarm response. Default is FFFF FFFF.
ASENSE [HI/LO]
Details Page 36
Changes the sense of the alarm output. Default
sense is HI.
BAUD [xxxxx abc]
Details Page 36
Set data communication parameters
CTS [0255]
Details Page 37
Program CTS delay in milliseconds.
(A value of 0 returns CTS immediately)
CTSHOLD [0-6000]
Details Page 38
Set/display hold time that CTS remains
present following last character transmission
from DD-25 port.
DEVICE [DCE, CTS KEY]
Details Page 38
Set device behavior; DCE (normal) or CTS Key
(Repeater)
INIT
Details Page 41
Initialize parameters to factory default values
MODE [M, R, R-M]
Details Page 41
Program operating mode, where M = Master,
R = Remote, R-M = Remote-Master (Remote
radio programmed to operate on Master fre-
quencies)
OWM [xxxxx]
Details Page 42
Program owners message
(30 characters maximum)
OWN [xxxxx]
Details Page 42
Program owners name
(30 characters maximum)
PWR [xx30]
Details Page 42
Program forward power output in dBm.
RTU [ON/OFF/0-80]
Details Page 43
Re-enables or disables the radios internal RTU
simulator and sets the RTU address.
RXTOT [NONE, 01440]
Details Page 43
Species max. duration (in minutes) to wait
before issuing a time-out alarm. Default is OFF.
SEND [n, -n, +n]
Details Page 43
Sets/displays re-send count for data packets.
Useful in areas with heavy radio interference.
TDD [ON/OFF]
Details Page 47
Sets or displays time-division multiplex status of
DATA INTERFACE connector. (Sometimes
referred to as simulated full-duplex mode.)
UNIT [1000065000]
Details Page 48
Program unit address. Used to set a unique
address for network-wide diagnostics.
ZONE DATA
Details Page 49
Show zone data statistics. Press Q to quit
ZONE CLEAR
Details Page 50
Reset zone data statistics
Table 6. Command Summary (Continued)
COMMAND DESCRIPTION
34 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
D
I
S
P
L
A
Y

O
P
E
R
A
T
I
N
G

S
T
A
T
U
S
ADDR [1...65000]
Details Page 36
Network address (1-65000)
AMASK [0000 0000FFFF
FFFF]
Details Page 36
Sets alarm mask (response). Default is FFFF
FFFF.
ASENSE [HI/LO]
Details Page 36
Changes the sense of the alarm output. Default
sense is HI.
BAUD [xxxxx abc]
Details Page 36
Display data communication parameters.
Example: BAUD 9600 8N1
BUFF [ON, OFF]
Details Page 37
Data buffering mode: ON = seamless data
OFF = fast byte throughput
CTS [0255]
Details Page 37
CTS delay in ms (0-255 ms)
DUMP Show all settings. Use with PC-based Radio
Conguration software (P/N 03-3156A01).
DEVICE [DCE, CTS KEY]
Details Page 38
Device behavior (DCE, or CTS KEY)
HOPTIME [XSHORT, 16, 20,
25, 32, SHORT, NORMAL,
LONG]
Details Page 40
Show hop time in milliseconds (ms).
HREV Hardware revision level
MODE [M, R, R-M]
Details Page 41
Show operating mode: M = Master, R =
Remote, R-M = Remote-Master (remote oper.
on master freqs.)
OWM Owners message or site name
OWN Owners name or system name
PWR [xx30]
Details Page 42
Forward power output setting in dBm
RSSI
Details Page 42
Received signal strength in dBm (continuously
updated). Not available at master radio unless
SETUP is enabled.
RXTOT [NONE, 01440]
Details Page 43
Species amount of time (in seconds) to wait
before issuing a time-out alarm. Default is
NONE.
SEND [n, -n, +n]
Details Page 43
Sets/displays re-send count for data packets.
Useful in areas with heavy radio interference.
SER Serial number of radio
SHOW [PORT, DC, PWR]
Details Page 45
Show active port, DC voltage or measured RF
power (dBm)
SIMPLEX [ON, OFF]
Details Page 45
Simplex/half-duplex selection
ON = Simplex, OFF = half-duplex
SKIP [NONE, 1...8]
Details Page 46
Skip a frequency operating zone
SKIPSYNC [ON/OFF]
Details Page 46
When ON, suppresses transmission of SYNC
messages in skipped zones. Default setting is
OFF.
Display parameters continued...
Table 6. Command Summary (Continued)
COMMAND DESCRIPTION
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 35
6.4 Detailed Command Descriptions
The essential commands for most applications are Network Address
(ADDR), Mode, (MODE) and Baud Rate (BAUD). However, proper use of
the additional commands allows you to tailor the transceiver for a spe-
cific use, or to conduct basic diagnostics on the radio. This section gives
more detailed information for many of the user commands listed in
Table 6.
Most of the commands below can be used in two ways. First, you can
type only the command name (for example, ADDR) to view the currently
programmed data. Second, you can set or change the existing data by
typing the command, followed by a space, and then the desired entry
(for example, ADDR 1234). In the list below, allowable programming
variables, if any, are shown in brackets [ ] following the command
name.
D
I
S
P
L
A
Y

O
P
E
R
A
T
I
N
G

S
T
A
T
U
S
(
C
O
N
T
I
N
U
E
D
)
SNR
Details Page 46
Signal-to-noise ratio. Expressed in dB.
SREV
Details Page 47
Display transceiver rmware revision level
STAT
Details Page 47
Show current alarm status
TDD [ON/OFF]
Details Page 47
Sets or displays time-division multiplex status of
DATA INTERFACE connector. (Sometimes
referred to as simulated full-duplex mode.)
TEMP
Details Page 48
Transceivers internal temperature (C)
UNIT [1000065000]
Details Page 48
Show programmed unit address for net-
work-wide diagnostics
ZONE DATA
Details Page 49
Show zone data statistics (see text for details).
Press Q to quit.
D
I
A
G
N
O
S
T
I
C
/
T
E
S
T
KEY Enables the transmitter.
(Radio must be in Setup mode.)
DKEY Disables the transmitter.
(Radio must be in Setup mode.)
DMGAP [xx]
Details Page 39
Sets the amount of time to wait after the
receipt of a character before interpreting the
next received character as the start of a new
message.
TX [xxxx]
Details Page 48
Set/display transmit test frequency.
(Radio must be in Setup mode.)
RX [xxxx]
Details Page 43
Set/display receive test frequency.
(Radio must be in Setup mode.)
SETUP
Details Page 44
Enables Setup mode. Times out after 15 min-
utes. Press Q to quit.
Table 6. Command Summary (Continued)
COMMAND DESCRIPTION
36 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
ADDR [1...65000]
This command sets or displays the radios network address. The net-
work address can range from 1 to 65000.
Network address must be programmed at the time of installation and
must be common across each radio in a given network. Radios are typi-
cally shipped with the network address unprogrammed. This causes the
address to display as NONE. This leaves the system in an invalid state and
prevents operation.
NOTE: It is recommended that the last four digits of the master radios
serial number be used for the network address (or chassis serial
number if the radio is installed in a P-20 redundant chassis).
AMASK [0000 0000FFFF FFFF]
This command sets the alarm bits that cause the alarm output signal to
be triggered. The PWR LED will still flash for all alarms, but the alarm
output signal will only be activated for those alarms that have the corre-
sponding mask bit set. The hex value for the mask aligns directly with
the hex value for the ALARM command. The default is FFFF FFFF.
Through proper use of the AMASK command, it is possible to tailor the
alarm response of the radio. Contact the factory for more information on
configuring the alarm mask.
ASENSE [HI/LO]
This command is used to set or display the sense of the alarm output at
Pin 25 of the DATA INTERFACE connector. The default for transceivers is
active HI.
BAUD [xxxxx abc]
This command sets or displays the communication attributes for the
DATA INTERFACE port. The command has no effect on the RJ-11
DIAG(NOSTICS) port.
The first parameter (xxxxx) is baud rate. Baud rate is specified in
bits-per-second and must be one of the following speeds: 1200, 2400,
4800, 9600, 19200, or 38400. In the worst case, the radio will always
accept a minimum of 500 data bytes in a single continuous data trans-
mission. At baud rates of 4800 bps or less, the radio can support unlim-
ited continuous data transmission at any hop rate. If hop time is set to
NORMAL or LONG, baud rates of up to 19200 bps with continuous unlim-
ited data transmission are possible. (See HOPTIME command.)
The second parameter of the BAUD command (abc) is a 3-character block
indicating how the data is encoded. The following is a breakdown of
each characters meaning:
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 37
a = Data bits (7 or 8)
b = Parity (N for None, O for Odd, E for Even)
c = Stop bits (1 or 2)
The factory default setting is 4800 baud, 8 data bits, no parity, 1 stop bit
(Example: 4800 8N1).
NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and are
not supported by the transceiver.
BUFF [ON, OFF]
This command sets or displays the received data handling mode of the
radio. The command parameter is either ON or OFF. (The default is ON.)
The setting of this parameter affects the timing of received data sent out
the DATA INTERFACE connector. Data transmitted over the air by the
radio is unaffected by the BUFF setting.
If data buffering is set to OFF, the radio will operate with the lowest pos-
sible average latency. Data bytes are sent out the DATA INTERFACE port
as soon as an incoming RF data frame is disassembled. Average and typ-
ical latency will both be below 10 ms, but idle character gaps may be
introduced into the outgoing data flow.
If data buffering is ON, the radio will operate in a seamless mode. That
is, data bytes will be sent over the air as quickly as possible, but the
receiver will buffer the data until enough bytes have arrived to cover
worst case gaps in transmission. The delay introduced by data buffering
may range from 25 to 50 ms, but the radio will not create any gaps in the
output data stream. This mode of operation is required for protocols
such as MODBUS that do not allow gaps in their data transmission.
Note that seamless mode (BUFF ON) is intended only for applications
where the transmitters baud rate is greater than or equal to the
receivers baud rate. Enforcement of this rule is left up to the user.
Changes to the BUFF setting may only be made at the master radio. This
is because the master radio broadcasts the buffer setting for the entire
network. At remote radios, the buffer setting may be read when the radio
is in synchronization with the master, but it may not be changed.
CTS [0255]
The CTS (clear-to-send) command sets or displays the timer value asso-
ciated with the CTS line response. The command parameter ranges from
0 to 255 milliseconds.
38 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
For DCE operation, the timer specifies how long to wait after the RTS
line goes high before asserting the CTS line. A timer value of zero
means that the CTS line will always be asserted (unless the radio is
attempting to throttle back data as part of normal flow control opera-
tion).
For CTS Key operation (see the DEVICE command), the timer specifies
how long to wait after asserting the CTS line before sending data out the
DATA INTERFACE port. A timer value of zero means that data will be sent
out the data port without imposing a key-up delay. (Other delays may be
in effect from other radio operating parameters.)
CTSHOLD [0-6000]
Used in DEVICE CTS KEY mode, this command sets the amount of time in
milliseconds that CTS remains present following transmission of the
last character out the RXD pin of the DATA INTERFACE port. This hold
time can be used to prevent squelch tail data corruption when inter-
working with other radios.
The CTSHOLD setting can range from 0 to 6000 (i.e., 6 seconds). The
default value is 0, which means that CTS will drop immediately after the
last character is transmitted. If the command is entered when the radio
is in DEVICE DCE mode, the response CTSHOLD N/A will be displayed.
DEVICE [DCE, CTS KEY]
The DEVICE command sets or displays the device behavior of the radio.
The command parameter is either DCE or CTS KEY.
The default selection is DCE. In this mode, CTS will go high following
RTS, subject to the CTS programmable delay time. Keying is stimulated
by the input of characters at the data port. Hardware flow control is
implemented by dropping the CTS line if data arrives faster than it can
be transmitted.
If CTS KEY is selected, the radio is assumed to be controlling another
radio, such as in a repeater system. The RTS line is ignored and the CTS
line is used as a keyline control for the other radio. CTS is asserted
immediately after the receipt of RF data, but data will not be sent out the
DATA INTERFACE port until after the CTS programmable delay time has
expired. (This gives the other radio time to key.)
Following transmission of the last byte of data, CTS will remain
asserted for the duration specified by the CTSHOLD command. CTSHOLD
should be set sufficiently high.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 39
DLINK [xxxxx]
DLINK followed by the baud rate sets the baud rate (bps) of the diagnos-
tics link. The following DLINK baud rates selections are allowed:
1200
2400
4800
9600
19200 (default setting)
Example: DLINK 4800 sets the RJ-11 DIAG port to operate at 4800 bps.
The default is DLINK 19200 and DLINK ON.
NOTE: The same baud rate must be entered into the appropriate
field(s) of any Network Management Software, if used.
DMGAP [xx]
The DMGAP command sets the amount of time in milliseconds to wait
after the receipt of a character before interpreting the next received char-
acter as the start of a new message. When data port baud rates are slow,
the gap between characters within a poll may be so long that the radio
interprets the next character as the start of a new poll. When diagnostics
is being performed using passive messaging (see Performing Net-
work-Wide Remote Diagnostics on page 53), this command may be used
to change this behavior.
DTYPE [NODE/ROOT/GATE/PEER]
The DTYPE command specifies the radios operational characteristics for
network-wide diagnostics. There are four possible types of nodes in a
network-wide diagnostics system.
The common types are:
NODEThe most common setting, and the default. This is the
basic system radio device-type. Typically, the radio network is
comprised of nodes and one root. Intrusive diagnostics can orig-
inate from any node. However, non-intrusive diagnostics can
only be conducted from the root node.
ROOTAlways one, and only one, per network. The root is the
focal point of network-wide diagnostics information. Intrusive
diagnostics can originate from any radio, including the root.
However, the root is the only radio through which non-intrusive
diagnostics can be conducted.
The default radio device-type is NODE. Less used are:
GATE
PEER
40 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
These node types are needed for repeater sub-networks and simplex
sub-networks where simplex frequencies are used. See the Net-
work-Wide Diagnostics System Handbook (05-3467A01) for an expla-
nation of these node types.
HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG]
The HOPTIME command sets or displays the hop time setting. The com-
mand is one of eight keywords whose parameters and related efficien-
cies are shown in Table 7.
Although the default setting is HOPTIME NORMAL, transmission effi-
ciency can usually be improved by using HOPTIME LONG when message
sizes typically exceed 256 bytes. This is because there will be less fre-
quent channel hops when using this setting, contributing to a smoother
flow of transmitted data.
Normally, HOPTIME NORMAL and LONG are the only settings required.
Other hoptimes can be used to customize performance based on SEND
count settings and payload data poll length.
The only time shorter settings (SHORT through XSHORT) should be con-
sidered is when the message size is very small and strong interference
of a persistent nature is occurring on many frequencies. In these cases,
a shorter hop time may improve the chances of a message getting
throughbut at the cost of reduced channel efficiency.
Changes to the HOPTIME setting may only be made at the master radio.
(This is because the master radio establishes the hop time setting for the
entire network.) At remote radios, the hop time setting may be read
when the radio is in synchronization with the master, but it may not be
changed.
Table 7. Hoptime Parameters
Hop Time
Keyword
Time
per
Hop
Max.
Bytes
per Hop
Channel
Efficiency
XSHORT 10 ms 9 32.1%
16 16 ms 21 46.7%
20 20 ms 30 53.6%
25 25 ms 39 55.7%
32 32 ms 57 63.3%
SHORT 40 ms 72 64.3%
NORMAL 80 ms 162 72.0%
LONG 160 ms 336 74.5%
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 41
INIT
The INIT command is used to reset the radios operating parameters to the
factory defaults. This may be helpful when trying to resolve configura-
tion problems that may have resulted from the entry of one or more
improper command settings. If you are unsure of which command set-
ting may have caused the problem, this command allows you to get back
to a known working state.
Use of the INIT command causes the changes shown in Table 8 to be
applied.
MODE [M, R, R-M]
The MODE command sets or displays the operating mode of the radio. A
master radio is designated by an M; a remote is designated by an R.
Table 8. Factory Default Values
Produced by INIT Command
Default Setting
Corresponding
Command
For all radios
Device operation DCE DEVICE DCE
RF output power 30 dBm (1 watt) PWR 30
CTS delay 0
(CTS is continuously
asserted)
CTS 0
DATA INTERFACE port 4800 baud
8 data bits
no parity
1 stop bit
BAUD 4800 8N1
Remote radios
Transmitter
test frequency
Per factory default TX xxx
Receiver
test frequency
Per factory default RX xxx
Master radios
Transmitter
test frequency
Per factory default TX xxx
Receiver
test frequency
Per factory default RX xxx
Skipped frequencies None (radio will hop
across all 1019
frequencies)
SKIP NONE
Hop time Normal (80 ms per hop) HOPTIME NORMAL
Simplex/duplex
operation
Half-duplex SIMPLEX OFF
Buffer mode Seamless data mode
enabled
BUFF ON
42 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
R-M indicates that the transceiver has been programmed to the special
remote-master mode (remote radio operating on master frequencies)
This is used in repeater-assisted peer-to-peer systems; see Section 2.2,
Typical Applications (beginning on Page 3) for details. The R-M mode
denotes a remote radio operating on master frequencies. In all other
respects, a remote-master behaves the same as a normal remote.
All units default to remotes; other modes must be specifically pro-
grammed with the MODE command.
OWM [xxxxx]
The OWM command sets or displays an optional owners message, such
as the system name. The entry can contain up to 30 characters.
OWN [xxxxx]
The OWN command sets or displays an optional owners name, such as
the site name. The entry can contain up to 30 characters.
PWR [xx30]
This command displays or sets the desired RF forward output power set-
ting of the radio. The PWR command parameter is specified in dBm and
can range from 20 to 30 dBm in 1 dBm steps. The default setting is 30
dBm (1 watt). To read the actual (measured) power output of the radio,
use the SHOW PWR command.
In the USA and Canada, maximum allowable power is governed by
limits on Effective Isotropic Radiated Power output (EIRP). The EIRP
limit of +36 dBm means that any user with a net antenna gain greater
than 6 dBi must decrease the PWR setting accordingly. Section 3.5, How
Much Output Power Can be Used? (beginning on Page 13) contains a
detailed discussion of this topic.
RSSI
This command displays the radios Received Signal Strength Indication
in dBm (decibels relative to 1 mW). The output can range from 50 dBm
to 110 dBm. Command availability and results depend on the mode of
operation (master or remote). The closer to 0 dBm, the stronger the
signal, thus a reading of 70 dBm is stronger than 80 dBm.
For a remote radio, under normal operation, RSSI is based on the
average signal strength of the SYNC message received in each of the
eight frequency zones. (RSSI is sampled each time a SYNC message is
receivedevery 1.6 seconds.) When using the RSSI reading to align a
directional antenna, it is important to make changes slowly so that the
RSSI reading will provide meaningful results. It will take several sec-
onds to indicate a change in signal level. The radio stays in RSSI mode
until is pressed. ENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 43
For a master radio, under normal operation, entering the RSSI command
causes the response NOT AVAILABLE to be returned. This is because a
master is normally receiving signals from several remote stations and an
RSSI reading would be continually changing. The only exception is
when the SETUP command has been asserted. This disables hopping and
allows reading a raw RSSI signal level in real time from a master or
remote radio.
NOTE: RSSI Readings are not accurate for incoming signals stronger
than 50 dBm.)
RTU [ON/OFF/0-80]
This command re-enables or disables the radios internal RTU simu-
lator, which runs with MDS proprietary polling programs (poll.exe and
rsim.exe). The internal RTU simulator is available whenever a radio has
diagnostics enabled. This command also sets the RTU address that the
radio will respond to.
The internal RTU can be used for testing system payload data or pseudo
bit error rate (BER) testing. It can be helpful in isolating a problem to
either the external RTU or the radio.
RX [xxxx]
This command sets or displays the test receive frequency used in place
of hopping whenever the radio is in Setup mode. The test receive fre-
quency can be reprogrammed to any value between 927.975 MHz and
902.025 MHz, inclusive. The factory default settings are listed below
and have been selected to be non-intrusive to normal operation.
RXTOT [NONE, 01440]
This command sets or displays the amount of time (in minutes) to wait
for the next received data packet before issuing a receiver time-out
alarm. The default is NONE.
SEND [n, -n, +n]
The SEND command selects or displays the number of times that a radio
will re-transmit data. This command is associated with robust or bul-
letproof operation of the radio and is intended for use in areas with
heavy radio interference.
Default Receive Frequencies
Master Remote
927.975 MHz 902.025 MHz
44 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
When the SEND command is issued without parameters, the cumulative
retransmission count is shown. A value of 1 represents the default selec-
tion, meaning normal, non-robust operation. Values greater than 1
successively improve the chance of successful data delivery in spec-
trally harsh environments. (Note that the SEND count for a remote radio
is only viewable when the remote is synchronized with its master sta-
tion.)
There are two formats for entering the SEND command. One format
(SEND n) can be used only at the master station, and selects the base
transmission count for the entire network. The other format (SEND +n or
n) can be used at any radio in the network, and provides a means to cus-
tomize the transmission count locally at each radio, as a delta (amount
of change) from the base.
For both formats, n represents number between 1 and 10; for the delta
format a value of zero is also permitted. The net transmission count for
a particular radio is determined by adding the local delta (+n or n) to
the base transmission count for the network. The net transmission count
is automatically bounded to the range 1..10, irrespective of the delta.
The combination of the two formats provides a means to highly cus-
tomize the retransmission behavior of network.
Higher retransmission counts come at the cost of increased latency and
reduced data throughput. With BUFF ON, the radio maintains seamless
operation based on timing derived from the network SEND value. The
use of any tailored SEND values (e.g. SEND +/-x) within the system may
disrupt seamless operation. This is because the increased latency makes
seamless mode impractical. Table 2 lists the maximum cumulative SEND
count for continuous operation, at some typical data rates.
SETUP
This command sets up the transceiver for checking antenna SWR or
transmitter power with external measuring equipment. Do not use this
mode during normal operation.
Table 9. Baud Rate vs. Maximum SEND Count
BAUD
RATE
(BPS)
XSHORT
(max. send
count)
16 ms
(max. send
count)
20 ms
(max. send
count)
25 ms
(max. send
count)
32 ms
(max. send
count)
SHORT
(max. send
count)
NORMAL
(max. send
count)
LONG
(max. send
count)
1200 3 8 10 10 10 10 10 10
2400 N/A 4 5 5 5 7 8 8
4800 N/A 2 2 2 2 3 4 4
9600 N/A N/A N/A N/A N/A N/A 2 2
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 45
When the SETUP command is entered, the HHT prompt changes to
SETUP>, and:
Hopping is disabled.
Synthesizer frequencies are reset to the test frequencies speci-
fied by the TX and RX commands.
The radio can be keyed using the KEY command. DKEY is used
to unkey the radio. (If the radio is left in a keyed state it is auto-
matically unkeyed after several minutes.)
The RSSI is sampled in a raw, continuous fashion regardless of
whether the unit is a master or a remote.
Entering Q or QUIT returns the system to normal operation.
A timer keeps the Setup mode from accidentally leaving the system dis-
abled. After 10 minutes the system behaves as if Q or QUIT had been
entered, returning to normal operation.
SHOW [PORT, DC, PWR]
The SHOW command displays three types of information based on the
command variables. These are:
PORTDisplays which connector port (RJ-11 or DB-25) is cur-
rently active for diagnostics and control.
DCDisplays DC input/output voltages.
PWRDisplays the actual (measured) RF power output in dBm.
Unlike the PWR command, this command shows the actual level
being measured, not the programmed RF power setting.
SIMPLEX [ON, OFF]
The SIMPLEX command sets or displays the radios mode of operation
(simplex or half-duplex).
By default, the system operates in half-duplex mode (SIMPLEX OFF). In
this mode, the transmit frequency of the master is the receive frequency
of the remote (and vice-versa). The transceiver uses a transmit/receive
frequency split of 1.6 MHz. The offset varies such that both frequen-
cies will always fit within the same zone. (A zone is a 3.2 MHz
sub-bandsee the ZONE DATA command.)
When simplex mode is selected (SIMPLEX ON), the master and remotes
always transmit and receive on the same frequency. This setting is
required for peer-to-peer simplex networks where remotes must be able
to communicate with other remotes. A slight increase in end-to-end
delay will occur when using this mode.
This command is read-only at remote radios. (Remotes must be syn-
chronized with the master radio to read the simplex status.)
46 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
SKIP [NONE, 1...8]
This command sets or displays which, if any, of the eight 3.2 MHz (128
frequency) zones will be skipped from the radios hopping sequence.
Skipping zones is one way of dealing with constant interference on one
or more frequencies. See Section 3.3 (Page 10) for more information on
dealing with interference.
Figure 24 shows the frequency range covered by each zone. The com-
mand parameter is either the keyword NONE or an undelimited string of
up to seven digits where each digit 1...8 represents a corresponding zone
to skip. (For zone parameter input, the digits can appear in any order and
can be optionally separated by a blank space.) The SKIP command is
read-only at remote radios. (Remotes must be synchronized with the
master radio to read the skip status.)
Figure 24. Frequency Zones for MDS 9810 Transceiver
SKIPSYNC [ON/OFF]
Selectively suppresses transmission of SYNC messages in skipped
zones (see SKIP command above). With SKIPSYNC set to ON, the trans-
ceiver will not transmit SYNC messages in skipped frequency zones.
This command is only available to transceivers that are set to be a master
(MODE M). The default setting for this command is OFF.
NOTE: Using SYNCSKIP when many zones are skipped will signifi-
cantly lengthen the time it takes a remote to achieve synchro-
nization with the master. (This will also manifest itself as very
slow RSSI reading response).
SNR
This command displays the signal-to-noise ratio of the received signal
expressed in dB. As used in this guide, the definition of signal-to-noise
is based upon the signal level following equalization, for valid frames
only. (A valid frame is defined as containing no more than one bit error,
and belonging to a frame addressed for the receiving radio.) SNR is
updated and latched for each valid frame received. A filter in the DSP
tempers the effect of any sudden changes in the value.
ZONE 1
902.200
to
905.375
ZONE 2
905.400
to
908.575
ZONE 3
908.600
to
911.775
ZONE 4
911.800
to
914.975
ZONE 5
915.000
to
918.175
ZONE 6
918.200
to
921.375
ZONE 7
921.400
to
924.575
ZONE 8
924.600
to
927.775
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 47
SNR output ranges from 10 dB to 33 dB. A value of 10 dB represents
little or no signal. A value of 24 dB represents a very strong signal. For
remote radios, a value of 0 is reserved to mean no signal; it is dis-
played whenever a remote is not in synchronization with the master sta-
tion.
When the SNR command is used, it causes the DIAG(NOSTIC) port to
enter an update mode, and it will provide an updated signal-to-noise
ratio every 1.6 seconds. It stays in this mode until the key is
pressed.
SREV
This command displays the software version currently loaded into the
transceiver.
A display of 06-3111A01, 3.5.1 is an example of the software version iden-
tifier.
STAT
This command is used to check alarm status. If no alarms exist, the mes-
sage NO ALARMS PRESENT appears at the top of the HHT display.
If an alarm does exist, a two-digit event code (0031) is displayed and
the event is identified as a major or minor alarm. A brief description
of the event is also given.
If more than one alarm exists, the word MORE appears at the bottom of
the screen and additional alarms are viewed by pressing the
key. Detailed descriptions of the alarm codes are provided in Table 12
on Page 52.
TDD [ON/OFF]
The TDD command selects or displays whether or not the DATA INTER-
FACE port is operating in time division duplex (sometimes called sim-
ulated full-duplex) mode. This command is read-only at remote
radios.
The x810 Transceiver is physically a half-duplex device. The radio can
never actually transmit and receive RF data at the same time. However,
TDD mode enables the radio to simulate full-duplex at the data port, by
designating alternate hops as transmit or receive hops, and buffering
(storing) data when transmission is not permitted. Default operation is
TDD OFF.
ENTER
ENTER
48 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Note that when TDD is enabled (TDD ON), there is a significant impact
on both data throughput and latency. Data throughput is roughly cut in
half. Worst case data latency is increased by two hoptimes. The effect in
seamless mode (BUFF ON) is even more pronounced, as shown in Table
10.
TEMP
This command displays the internal temperature of the transceiver in
degrees Celsius. (Note that the radio is specified to operate in an envi-
ronment between 30 C and +60 C). This internal reading may be
higher than the outside temperature by several degrees.
TX [xxxx]
This command sets or displays the test transmit frequency used in place
of hopping whenever the radio is in Setup mode. The test transmit fre-
quency can be reprogrammed to any value between 902.025 MHz and
927.975 MHz, inclusive. The factory default settings are listed below
and have been selected to be non-intrusive to normal system operation.
UNIT [1000065000]
This command sets the unit addressing for network-wide diagnostics.
The unit address is factory programmed to the last four digits of the
serial number. If re-programmed in the field, the entry must consist of
five digits between 10000 and 65000.
Table 10. Hoptime Setting vs. Delay (BUFF ONSeamless Mode)
HOP TIME MINIMUM DELAY MAXIMUM DELAY
XSHORT 33 ms 66 msec
16 39 ms 78 ms
20 43 ms 86 ms
25 48 ms 96 ms
32 55 ms 110 ms
SHORT 63 ms 126 msec
NORMAL 103 ms 206 msec
LONG 183 ms 366 msec
Default Transmit Frequencies
Master Remote
902.025 MHz 927.975 MHz
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 49
ZONE DATA
The transceiver divides its frequency operating spectrum into eight con-
tiguous 3.2 MHz zones. (These are the same zones referenced by the
SKIP command described earlier.) Data frame statistics are maintained
for each zone to indicate the transmission quality through the network.
This information is useful for identifying zones where significant inter-
ference exists.
Zone quality information can be accessed using the ZONE DATA com-
mand on a connected HHT. For each zone (18), it shows you the
number of data frames sent, the number received, and the number
received with errors. If an excessive number of errors are seen in one or
more frequency zones, it may indicate interference, and you should con-
sider skipping those zones using the SKIP command.
The ZONE DATA command displays its information on four lines as shown
in Figure 25. If the display seems to roll off the screen, verify that
your HHT is set for an 80 character screen size. See Section 6.2,
Hand-Held Terminal Setup (beginning on Page 29).
Invisible place holder
Figure 25. HHT Display for ZONE DATA Command
If ZONE DATA alone is entered, the information for Zone 1 is displayed
first. Successive zones can be viewed by pressing the ENTER key, or by
entering the zone number of your choice (1...8) at the NEXT ZONE?>
prompt.
It is also possible to go directly to a specific zone by entering ZONE DATA
[1...8], where the number entered equals the desired zone. Data for the
specified zone is displayed and then control returns to the command
prompt.
Entering Q or QUIT causes the program to exit and return to the command
prompt.
TOTAL SENT
TOTAL RECEIVED
TOTAL REC'D WITH ERRORS
ZONE #
DATA FRAME STATISTICS
50 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
A variation on the ZONE DATA command is ZONE DATA! This causes data
to be retrieved from all zones. Data is sequentially displayed for each of
the 8 zones and then control returns to the command prompt.
(Note: If a frequency zone has been skipped, statistics will still be gath-
ered for that zone when ZONE DATA is invoked at a remote site, but the
numbers will accumulate very slowly since the only data being passed
in a skipped zone is the radios synchronization signal. When invoked
at a master, no polls will be received from a skipped zone.)
ZONE CLEAR
The ZONE CLEAR command clears the zone data for all zones, resetting
the count to 0. (Zone data is also cleared automatically upon reboot, or
upon saturation of a zone data counter.)
7.0 TROUBLESHOOTING
Successful troubleshooting of an MDS transceiver system is not diffi-
cult, but requires a logical approach. It is best to begin troubleshooting
at the master station, as the rest of the system depends on the master for
polling instructions and synchronization data. If the master station has
problems, the operation of the entire network will be affected.
When communication problems are found, it is good practice to begin
by checking the simple things. All radios in the network must meet these
basic requirements:
Adequate and stable primary power
An efficient and properly aligned antenna system
Secure connections (RF, data & power)
Proper programming of the radios operating parameters, espe-
cially Mode selection (MODE), Network Address (ADDR), and
interface Baud Rate (BAUD)
The correct interface between the radio and the connected data
equipment (proper cable wiring, data format and timing).
7.1 LED Indicators
The LED status indicators are an important troubleshooting tool and
should be checked whenever a problem is suspected. Table 11 describes
the function of each status LED.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 51
7.2 Alarm Codes
When an alarm condition exists, the transceiver creates an alarm code
that can be read on an HHT connected to the radios DIAG(NOSTICS)
port. These codes can be very helpful in resolving many system difficul-
ties.
Checking for AlarmsSTAT command
To check for the presence of alarms, enter STAT on the HHT. If no alarms
exist, the message NO ALARMS PRESENT appears at the top of the display.
If an alarm does exist, a two-digit alarm code (0031) is displayed, and
it is identified as a major or minor alarm. A brief description of the alarm
is also given. Alarm codes and their meanings are listed in Table 12.
If more than one alarm exists, the word MORE appears at the bottom of
the screen; additional alarms can be viewed by pressing .
Major Alarms vs. Minor Alarms
Major alarms report serious conditions that generally indicate a hard-
ware failure, or other abnormal condition that will prevent (or seriously
hamper) further operation of the transceiver.
With the exception of alarm code 00 (network address not pro-
grammed), major alarms generally indicate the need for factory repair.
Contact MDS for further assistance.
Minor alarms report conditions which, under most circumstances, will
not prevent transceiver operation. This includes out-of-tolerance condi-
tions, baud rate mismatches, etc. The cause of these alarms should be
investigated and corrected to prevent system failure.
PWR SYNC TXD RXD
Table 11. LED Status Indicators
LED Name Description
PWR ContinuousPower is applied to the radio, no problems detected.
Flashing 5 times per secondFault indication.
See Section 7.0, TROUBLESHOOTING (beginning on Page 50).
Flashing once every 4 secondsRadio is in Sleep Mode.
SYNC Lights continuously to indicate the radio is receiving/sending
synchronization frames. Within 16 seconds of start-up, this LED
should be lit continuously.
TXD Indicates EIA-232 space signal (logic high) input to the DB-25
connector.
RXD Indicates EIA-232 space signal (logic high) output from the DB-25
connector.
ENTER
52 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Alarm Code Definitions
Table 12 contains a listing of all event codes that may be reported by the
transceiver.
Table 12. Alarm Codes
Alarm
Code
Alarm
Type Description
00 Major The network address is not programmed.
01 Major Improper software detected for this radio model.
02, 03 -- Reserved for factory use.
04 Major One or more of the programmable synthesizer loops is
reporting an out-of-lock condition.
05 -- Reserved for factory use.
06 Major Analog-to-Digital (A-to-D) fault.
07 Major One or more of the radios internal voltage regulators is
reporting a failure. The radio will not operate.
08 Major The system is reporting that it has not been calibrated. Factory
calibration is required for proper radio operation.
09 -- Reserved for factory use.
10 Major The microcontroller unit (MCU) was unable to properly
program the system to the appropriate defaults. A hardware
problem may exist.
11 -- Reserved for factory use.
12 Major Receiver time-out alarm.
13-15 -- Reserved for factory use.
16 Minor The unit address is not programmed.
17 Minor A data parity fault has been detected on the DATA
INTERFACE connector. This usually indicates a parity setting
mismatch between the radio and the RTU.
18 Minor A data framing error has been detected on the DATA
INTERFACE connector. This may indicate a baud rate
mismatch between the radio and the RTU.
1924 -- Reserved for factory use.
25 Minor The 6.0 volt power regulator is out-of-tolerance. If the error is
excessive, operation may fail.
26 Minor The dc input voltage is out-of-tolerance. If the voltage is too far
out-of-tolerance, operation may fail.
27, 28 -- Reserved for factory use.
29 Minor RF output power fault detected. (Power differs by more than 2
dB from set level.) Often caused by high antenna system
SWR. Check antenna, feedline and connectors.
30 Minor The system is reporting an RSSI reading below 105 dBm. Bit
errors are likely to be present in the data.
31 Minor The transceivers internal temperature is approaching an
out-of-tolerance condition. If the temperature drifts outside of
the recommended operating range, system operation may
fail.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 53
7.3 Performing Network-Wide Remote Diagnostics
Diagnostics data from a remote radio can be obtained by connecting a
laptop or personal computer running MDS Network Management Soft-
ware to any radio in the network. Figure 30 shows an example of a setup
for performing network-wide remote diagnostics.
Invisible place holder
Figure 26. Network-Wide Remote Diagnostics Setup
If a PC is connected to any radio in the network, intrusive polling
(polling which briefly interrupts payload data transmission) can be per-
formed. To perform diagnostics without interrupting payload data trans-
mission, connect the PC to a radio defined as the root radio. A radio
is defined as a root radio using the DTYPE ROOT command locally, at the
radio.
RTU
RTU
TO
DAGNOSTCS
PORT
TO DATA
PORT
REPEATER
POLLNG REMOTE
ROOT NODE
REMOTE NODE
OPERATON
Intrusive messaging only
(not preferred)
DAGNOSTCS
COMPUTER
RUNNNG nSite
TO RJ-11
DAGNOSTCS
PORT
RTU
DTYPE
ROOT
DAGNOSTCS DATA
(To InSite)
HOST COMPUTER
PAYLOAD DATA
(To SCADA application)
ROOT NODE OPERATON
Active messaging or
passive messaging (preferred)
54 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
A complete explanation of remote diagnostics can be found in MDS
Network-Wide Diagnostics System Handbook (MDS P/N
05-3467A01).
1. Program one radio in the network as the root radio by entering the
DTYPE ROOT command at the radio.
2. At the root radio, use the DLINK ON and DLINK [baud rate] commands
to congure the diagnostic link protocol on the RJ-11 port.
3. Program all other radios in the network as nodes by entering the
DTYPE NODE command at each radio.
4. Use the DLINK ON and DLINK [baud rate] commands to congure the
diagnostic link protocol on the RJ-11 port of each node radio.
5. Connect same-site radios using a null-modem cable at the radios
diagnostic ports.
6. Connect a PC on which MDS Network Management Software is
installed to the root radio, or to one of the nodes, at the radios diag-
nostic port. (This PC may be the PC being used to collect payload
data, as shown in Figure 30.)
To connect a PC to the radios DIAG. port, an RJ-11 to DB-9 adapter
(MDS P/N 03-3246A01) is required. If desired, an adapter cable
may be constructed from scratch, using the information shown in
Figure 27.
Invisible place holder
Figure 27. RJ-11 to DB-9 Adapter Cable
Table 13. Network-Wide Diagnostics Radio Setup Commands
COMMAND DESCRIPTION
N
E
T
W
O
R
K
-
W
I
D
E
D
I
A
G
N
O
S
T
I
C
S
C
O
N
F
I
G
U
R
A
T
I
O
N
DLINK [xxxxx]
Details Page 55
Set baud rate of diagnostics link
DTYPE
[NODE/ROOT/GATE/PEER]
Details Page 55
Set radios operational characteristics
for network-wide diagnostics
RXD
TXD
GND
2
3
5
DB-9 FEMALE
(TO COMPUTER)
TXD
RXD
GND
4
5
6
RJ-11 PLUG
(TO RADIO)
RJ-11 PIN LAYOUT
1
6
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 55
7. Launch the MDS Network Management application at the PC.
(Refer to the software users manual for details.)
DLINK [xxxxx]
DLINK followed by the baud rate sets the baud rate (bps) of the diagnos-
tics link. The following DLINK baud rates selections are allowed:
1200
2400
4800
9600
19200 (default setting)
Example: DLINK 4800 sets the RJ-11 DIAG port to operate at 4800 bps.
The default is DLINK 19200 and DLINK ON.
NOTE: The same baud rate must be entered into the appropriate
field(s) of any Network Management Software, if used.
DTYPE [NODE/ROOT/GATE/PEER]
The DTYPE command specifies the radios operational characteristics for
network-wide diagnostics. There are four possible types of nodes in a
network-wide diagnostics system.
The common types are:
NODEThe most common setting, and the default. This is the
basic system radio device-type. Typically, the radio network is
comprised of nodes and one root. Intrusive diagnostics can orig-
inate from any node. However, non-intrusive diagnostics can
not be facilitated through a node.
ROOTAlways one, and only one, per network. The root is the
focal point of network-wide diagnostics information. Intrusive
diagnostics can originate from any radio, including the root.
However, the root is the only radio enabling non-intrusive diag-
nostics.
The default radio device-type is NODE. Less used are:
GATE
PEER
These node types are needed for repeater sub-networks and simplex
sub-networks where simplex frequencies are used. See the Net-
work-Wide Diagnostics System Handbook for an explanation of these
node types.
56 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
7.4 Troubleshooting Chart
Table 14 provides suggestions for resolving system difficulties that may
be experienced in the radio system. If problems persist, contact the fac-
tory for further assistance. Refer to the inside back cover of this guide
for contact information.
8.0 TECHNICAL REFERENCE
The following section contains material that is not essential to using the
radio, but may prove helpful in diagnosing performance problems or in
gaining a better understanding of the units operation.
8.1 Technical Specifications
GENERAL
Frequency Hopping Range: Up to 1019 frequencies within:
902928 MHz,
configurable in 3.2 MHz zones
Hop Pattern: Based on network address
Frequency Stability: 1.5 ppm
Simplex Operation: User selectable
Half-Duplex Operation: 1.6 MHz TX/RX split
Table 14. Troubleshooting Chart
Difficulty Recommended System Checks
Unit is
inoperative.
a. Check for the proper supply voltage at the power connector.
b. The transceivers internal resettable fuse may have tripped. To
reset it, momentarily remove and re-apply power to the radio.
Interference is
suspected.
a. Verify that the system has a unique network address. Nearby
systems with the same address will cause interference.
b. Use the ZONE DATA command (Page 49) to check for
interference in specific zones. Lock out affected zone(s) using
the SKIP command (Page 46).
c. If omnidirectional antennas are used on remote stations,
consider changing to directional antennas. This will often limit
interference to and from other stations.
No
synchronization
with master, or
poor overall
performance.
a. Check for secure interface connections at the radio and the
connected device.
b. Check the antenna, feedline and connectors. Reflected power
should be less than 10% of the forward power reading
(SWR 2:1 or lower).
c. If the remote radio is in synchronization, but performance is
poor, check the received signal strength using the RSSI
command (Page 42). If RSSI is low, it may indicate antenna
problems, or misalignment of directional antenna headings.
d. Verify proper programming of system parameters: mode,
network address, data interface baud rate, transmitter power,
CTS delay, etc. It may be helpful to use the INIT command
(Page 41), which resets all parameters to factory defaults.
e. Check for alarms using the STAT command (Page 47)
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 57
Network Addresses: 65,000
Temperature Range: 30C to +60C
Humidity: 95% at +40C; non-condensing
Primary Power: 13.8 Vdc (10.530 Vdc range)*
* Transceivers shipped prior to Revision U
(November 1999) may be configured for 25 Vdc
maximum DC input.
Supply Current (typical):
Transmit: 400 mA @ 13.8 Vdc
Receive: 125 mA @ 13.8 Vdc
Sleep Mode: <30 mA @ 13.8 Vdc
Size (excluding mtg. hardware): 2.0" x 5.62" x 7.25"
51 x 143 x 184 mm
Weight: 2.38 lb/1.08 kg
Case: Die-cast aluminum
Approvals: FCC Part 15.247
Industry Canada RSS-210 and RSS-139
CSA/US Class 1, Div. 2; Groups A, B, C and D
hazardous locations
Contact MDS for information on availability and
governmental approvals in other countries
DATA CHARACTERISTICS
Data Interface: EIA-232 signaling standard
Interface Connector: DB-25 female
Data Rate: 1200, 2400, 4800, 9600, 19200, 38400 bps
asynchronous
Data Latency: <10 ms typical (buffer off)
Byte Length: 10 or 11 bits
Maximum Data Transmission: Continuous up to 19200 bps;
Non-continuous at 38400 bps
RF CHARACTERISTICS
TRANSMITTER:
Power Output
(at antenna connector): 0.1 to 1.0 watt (+20 dBm to +30 dBm) 1.0 dB, set
by user
Duty Cycle: Continuous
Modulation Type: Binary CPFSK
Output Impedance: 50 Ohms
Spurious: 60 dBc
Harmonics: 80 dBc
RECEIVER
Type: Double conversion superheterodyne
Bit-Error Rate: Less than 1x10
-
6
at 110 dBm
Intermodulation: 59 dB minimum (EIA)
58 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Desensitization: 75 dB
Spurious: 70 dB minimum
Bandwidth: 25 kHz
Interference Ratio
(BER degraded by 10
-1
): Co-channel: 10 dB
Adjacent channel: +30 dB
Two channels away: +50 dB
Three channels away: +60 dB
Time Required to Synchronize
with Master Radio: Less than 13 seconds (typical)
8.2 RSSI Checks with a Voltmeter
As an alternative to the HHT method of measuring RSSI (see Antenna
Aiming on page 27), a dc voltmeter may be connected to Pin 21 of the
transceivers DATA INTERFACE connector.
Figure 28 shows the relationship between RSSI and the dc voltage at Pin
21.
NOTE: RSSI Readings are not accurate for incoming signals stronger
than 50 dBm.)
Invisible place holder
Figure 28. RSSI vs. Vdc at Pin 21 of DATA INTERFACE Connector
8.3 Data Interface Connections (DB-25)
The DATA INTERFACE connector is used to connect the radio to an
external DTE data terminal that supports the EIA-232 format. The radio
supports data rates of 1200, 2400, 4800, 9600, 19200 and 38400 bps
(asynchronous data only).
The DATA INTERFACE connector mates with a standard DB-25 plug that
is available from many electronics parts distributors. Figure 29 shows
the layout of the DATA INTERFACE connector.Table 15 lists each pin on
the connector and describes its function.
2
2.5
3
3.5
4

1
1
0

9
0

7
0

5
0
+

D
C

V
O
L
T
S

(
P
I
N

2
1
)
SIGNAL LEVEL (dBm)
4.5
5.0
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 59
Invisible place holder
Figure 29. Data Interface Connector (DB-25) Pins
(As viewed from outside the radio)
Unused
Radio Inhibit (Sleep)
Unused
13
12
11
10
9
8
7
6
5
4
3
2
1
Receiver Unsquelched Sensor
Unused
Data Carrier Detect (DCD)
Signal Ground*
Data Set Ready (DSR)
Clear-to-Send Output (CTS)
Request-to-Send Input (RTS)
Received Data (RXD)*
Transmitted Data (TXD)*
Protective Ground
25
24
23
22
21
20
19
18
17
16
15
14
Alarm Output
Analog Input Pin
Diagnostic Channel Enable
RSSI Voltage
9.9 Vdc Regulated Output
Unregulated DC Input/Output
Digital Output Pin
Unused
Unused
Unused
Pin
Description
Pin
No.
Pin
No.
Pin
Description
Unused
Future use do not connect
* Required in most installations
Table 15. Data Interface Connector (DB-25) Pin Descriptions
Pin
Number
Input/
Output Pin Description
1 -- Protective Ground
Connects to ground (negative supply potential) on the
radios PC board and chassis.
2 IN TXDTransmitted Data
Accepts TX data from the connected device.
3 OUT RXDReceived Data
Supplies received data to the connected device.
4 IN RTSRequest-to-Send Input
5 OUT CTSClear-to-Send Output
Goes high after the programmed CTS delay time has
elapsed (DCE), or keys an attached radio when RF data
arrives (CTS KEY).
6 OUT DSRData Set Ready
Provides a +6 Vdc DSR signal through a 2.5 k resistor.
7 -- Signal Ground
Connects to ground (negative supply potential) at the
radios PC board.
8 OUT DCDData Carrier Detect
A high indicates hopping synchronization.
9 -- Unused.
10 OUT RUSReceiver Unsquelched Sensor
Provides +8 Vdc through a 1 k resistor whenever the
receiver squelch is open, and drops to less than 1 Vdc
when the squelch is closed.
11 -- Unused.
12 IN Sleep Mode
A ground on this pin turns off most circuits in the radio,
including transmit, receive, modem and diagnostic
functions. This allows for greatly reduced power
consumption, yet preserves the radios ability to be
quickly brought on line. See Section 4.6, Using the
Radios Sleep Mode (beginning on Page 25) for details.
13 -- Unused.
60 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
8.4 Bench Testing Setup
Figure 30 shows a sample test setup that can be used to verify the basic
operation of MDS radios. This test can be performed with any number
of remote radios by using a power divider with the required number of
output connections.
14 -- Unused.
15 -- Do not connectFactory test point.
16 -- Unused.
17 -- Digital Output Pin
Output value is 3 Vdc for set and 0 Vdc for clear. May be
activated via MDS Network Management Software.
18 IN/OUT Accessory Power
Unregulated input/output. Provides a source of power
for low-current accessories. The supply voltage may be
between 11.0 and 25 volts.
19 OUT 9.9 Vdc Regulated Output
Provides a source of regulated voltage at 100 mA for
low-power accessories.
20 -- Do not connectReserved for future use.
21 OUT RSSIReceived Signal Strength Indication
A dc voltmeter may be connected to this pin to read the
relative strength of the incoming signal. Figure 28 on
page 58 compare RSSI to dc voltage.
22 -- Unused.
23 IN Diagnostic Channel Enable
A ground on this pin causes the radios microcontroller
to open the DB-25 DATA INTERFACE connector for
diagnostics and control (in place of the more commonly
used RJ-11 DIAG(NOSTICS) connector).
24 IN Analog Input Pin
Input value can range between 0 and 5 volts DC.
Voltage must not exceed 5 Vdc or damage may result.
Analog input voltage may be monitored via MDS
Network Management software, where the 0-5 Vdc
range is translated to a value between 0 and 255 (hex
address 0xFF).
25 OUT Alarm Output
A logic low (less than 0.5 volts) on this pin indicates
normal operation. A logic high (greater than 4 volts)
indicates that an alarm condition is present. This pin can
be used as an alarm output, provided the internal series
resistance of 1 k is considered.
Table 15. Data Interface Connector (DB-25) Pin
Pin
Number
Input/
Output Pin Description
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 61
The RTU simulator shown in the test setup (MDS Part No. 03-2512A01)
is a microcontroller that emulates a remote terminal unit operating at
1200, 2400, 4800, or 9600 bps. Custom software is supplied with the
RTU simulator that allows continuous polling of remote radios. The
software reports the number of polls sent, polls received, and the number
of errors detected. The software runs on an IBM-compatible personal
computer.
NOTE: It is very important to use attenuation between all units in the
test setup. The amount of attenuation required will depend on
the number of units being tested and the desired signal strength
(RSSI) at each transceiver during the test. In no case should a
signal greater than 50 dBm be applied to any transceiver in
the test setup.
Invisible place holder
Figure 30. Typical Setup for Bench Testing of Radios
8.5 Using Radio Configuration Software
Windows-based Radio Configuration software (MDS P/N 03-3156A01)
is used for upgrading the internal radio software when new features
become available from Microwave Data Systems. The software
includes on-line user instructions, and an installation booklet is provided
with the software package. Contact MDS for ordering information.
NOTE: The latest firmware revision for all MDS products may be
obtained at www.microwavedata.com.
Connecting a PC
To connect a PC to the radios DIAG(NOSTICS) port, an RJ-11 to DB-9
adapter cable (MDS P/N 03-3246A01) is required. If desired, this cable
may be constructed from scratch using the information shown in
Figure 31.
A N T E N N A 1 3 . 8 VDC+
A N T E N N A 1 3 . 8 VDC +
A N T E N N A 1 3 . 8 VDC +
POWER ATTENUATORS
Fixed or adjustable
2W Minimum Rating
POWER DIVIDER
NON-RADIATING ATTENUATORS
Install on Unused Divider Ports (if any)
2W Minimum Rating
RTU SIMULATORS
MDS P/N 03-2512A01
REMOTE
REMOTE
REMOTE
COMPUTER RUNNING
MDS POLLING SOFTWARE
A N T E N N A 1 3 . 8 VDC +
MASTER
62 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Upgrading the Radios Software
Using the Radio Configuration software, select RADIO SOFTWARE
UPGRADE under the SYSTEM menu. Follow the prompts and on-line
instructions to complete the upgrade procedure.
Software upgrades are distributed as ASCII files with a .S28 extension.
These files use the Motorola S-record format. When the download is
activated, the radios PWR LED will flash rapidly, confirming that a
download is in process. The download takes about two minutes.
NOTE: If a download fails, the radio is left unprogrammed and inop-
erative. This is indicated by the PWR LED flashing slowly (1
second on/1 second off). This condition is only likely to occur
if there is a power failure to the computer or radio during the
downloading process. The download can be attempted again
when the fault has been corrected.
Invisible place holder
Figure 31. RJ-11 to DB-9 Adapter Cable
(for software upgrade using connected PC)
RXD
TXD
GND
2
3
5
DB-9 FEMALE
(TO COMPUTER)
TXD
RXD
GND
4
5
6
RJ-11 PLUG
(TO RADIO)
RJ-11 PIN LAYOUT
1
6
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 63
8.6 dBm-Watts-Volts Conversion Chart
Table 16 is provided as a convenience for determining the equivalent
voltage or wattage of an RF power expressed in dBm.
Table 16. dBm-Watts-Volts Conversionfor 50 ohm Systems
9.0 GLOSSARY OF TERMS
If you are new to spread spectrum radio, some of the terms used in this
guide may be unfamiliar. The following glossary explains many of these
terms and will prove helpful in understanding the operation of the trans-
ceiver.
dBm V Po
+53 100.0 200W
+50 70.7 100W
+49 64.0 80W
+48 58.0 64W
+47 50.0 50W
+46 44.5 40W
+45 40.0 32W
+44 32.5 25W
+43 32.0 20W
+42 28.0 16W
+41 26.2 12.5W
+40 22.5 10W
+39 20.0 8W
+38 18.0 6.4W
+37 16.0 5W
+36 14.1 4W
+35 12.5 3.2W
+34 11.5 2.5W
+33 10.0 2W
+32 9.0 1.6W
+31 8.0 1.25W
+30 7.10 1.0W
+29 6.40 800mW
+28 5.80 640mW
+27 5.00 500mW
+26 4.45 400mW
+25 4.00 320mW
+24 3.55 250mW
+23 3.20 200mW
+22 2.80 160mW
+21 2.52 125mW
+20 2.25 100mW
+19 2.00 80mW
+18 1.80 64mW
+17 1.60 50mW
+16 1.41 40mW
+15 1.25 32mW
+14 1.15 25mW
+13 1.00 20mW
+12 .90 16mW
+11 .80 12.5mW
+10 .71 10mW
+9 .64 8mW
+8 .58 6.4mW
+7 .500 5mW
+6 .445 4mW
+5 .400 3.2mW
+4 .355 2.5mW
+3 .320 2.0mW
+2 .280 1.6mW
+1 .252 1.25mW
dBm V Po
0 .225 1.0mW
-1 .200 .80mW
-2 .180 .64mW
-3 .160 .50mW
-4 .141 .40mW
-5 .125 .32mW
-6 .115 .25mW
-7 .100 .20mW
-8 .090 .16mW
-9 .080 .125mW
-10 .071 .10mW
-11 .064
-12 .058
-13 .050
-14 .045
-15 .040
-16 .0355
dBm mV Po
-17 31.5
-18 28.5
-19 25.1
-20 22.5 .01mW
-21 20.0
-22 17.9
-23 15.9
-24 14.1
-25 12.8
-26 11.5
-27 10.0
-28 8.9
-29 8.0
-30 7.1 .001mW
-31 6.25
-32 5.8
-33 5.0
-34 4.5
-35 4.0
-36 3.5
-37 3.2
-38 2.85
-39 2.5
-40 2.25 .1W
-41 2.0
-42 1.8
-43 1.6
-44 1.4
-45 1.25
-46 1.18
-47 1.00
-48 0.90
dBm mV Po
-49 0.80
-50 0.71 .01W
-51 0.64
-52 0.57
-53 0.50
-54 0.45
-55 0.40
-56 0.351
-57 0.32
-58 0.286
-59 0.251
-60 0.225 .001W
-61 0.200
-62 0.180
-63 0.160
-64 0.141
dBm V Po
-65 128
-66 115
-67 100
-68 90
-69 80
-70 71 .1nW
-71 65
-72 58
-73 50
-74 45
-75 40
-76 35
-77 32
-78 29
-79 25
-80 22.5 .01nW
-81 20.0
-82 18.0
-83 16.0
-84 11.1
-85 12.9
-86 11.5
-87 10.0
-88 9.0
-89 8.0
-90 7.1 .001nW
-91 6.1
-92 5.75
-93 5.0
-94 4.5
-95 4.0
-96 3.51
-97 3.2
dBm V Po
-98 2.9
-99 2.51
-100 2.25 .1pW
-101 2.0
-102 1.8
-103 1.6
-104 1.41
-105 1.27
-106 1.18
dBm nV Po
-107 1000
-108 900
-109 800
-110 710 .01pW
-111 640
-112 580
-113 500
-114 450
-115 400
-116 355
-117 325
-118 285
-119 251
-120 225 .001pW
-121 200
-122 180
-123 160
-124 141
-125 128
-126 117
-127 100
-128 90
-129 80 .1W
-130 71
-131 61
-132 58
-133 50
-134 45
-135 40
-136 35
-137 33
-138 29
-139 25
-140 23 .01W
64 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
Antenna System GainA figure, normally expressed in dB, repre-
senting the power increase resulting from the use of a gain-type antenna.
System losses (from the feedline and coaxial connectors, for example)
are subtracted from this figure to calculate the total antenna system gain.
BitThe smallest unit of digital data, often represented by a one or a
zero. Eight bits (plus start, stop, and parity bits) usually comprise a byte.
Bits-per-secondSee BPS.
BPSBits-per-second. A measure of the information transfer rate of
digital data across a communication channel.
ByteA string of digital data usually made up of eight data bits and
start, stop and parity bits.
Decibel (dB)A measure of the ratio between two signal levels. Fre-
quently used to express the gain (or loss) of a system.
Data Circuit-terminating EquipmentSee DCE.
Data Communications EquipmentSee DCE.
Data Terminal EquipmentSee DTE.
dBiDecibels referenced to an ideal isotropic radiator in free space.
Frequently used to express antenna gain.
dBmDecibels referenced to one milliwatt. An absolute unit used to
measure signal power, as in transmitter power output, or received signal
strength.
DCEData Circuit-terminating Equipment (or Data Communications
Equipment). In data communications terminology, this is the modem
side of a computer-to-modem connection. By default, MDS transceivers
are set as DCE devices.
Digital Signal ProcessingSee DSP.
DSPDigital Signal Processing. In the MDS 9810 transceiver, the DSP
circuitry is responsible for the most critical real-time tasks; primarily
modulation, demodulation, and servicing of the data port.
DTEData Terminal Equipment. A device that provides data in the
form of digital signals at its output. Connects to the DCE device.
EqualizationThe process of reducing the effects of amplitude, fre-
quency or phase distortion with compensating networks.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 65
Fade MarginThe greatest tolerable reduction in average received
signal strength that will be anticipated under most conditions. Provides
an allowance for reduced signal strength due to multipath, slight antenna
movement or changing atmospheric losses. A fade margin of 20 to 30
dB is usually sufficient in most systems.
FrameA segment of data that adheres to a specific data protocol and
contains definite start and end points. It provides a method of synchro-
nizing transmissions.
Frequency HoppingThe spread spectrum technique used by the
MDS 9810 transceiver, where two or more associated radios change
their operating frequencies several times per second using a set pattern.
Since the pattern appears to jump around, it is said to hop from one
frequency to another.
Frequency ZoneThe transceivers use up to 1,019 discrete channels
in the 902 to 928 MHz spectrum. A group of 128 channels is referred to
as a zone. The transceivers use eight frequency zones. (Five channels are
reserved for network control purposes.)
Hardware Flow ControlA transceiver feature used to prevent data
buffer overruns when handling high-speed data from the RTU or PLC.
When the buffer approaches overflow, the radio drops the clear-to-send
(CTS) line, which instructs the RTU or PLC to delay further transmis-
sion until CTS again returns to the high state.
Host ComputerThe computer installed at the master station site,
which controls the collection of data from one or more remote sites.
LatencyThe delay (usually expressed in milliseconds) between when
data is applied to TXD (Pin 2) at one radio, until it appears at RXD
(Pin 3) at the other radio.
MASMultiple Address System. A radio system where a central
master station communicates with several remote stations for the pur-
pose of gathering telemetry data. Figure 3 on page 3 shows an example
of an MAS system.
Master (Station)The one radio transceiver in a spread spectrum net-
work that automatically provides synchronization information to one or
more associated remote transceivers. A radio may be programmed for
either master or remote mode using software commands. See Section
6.0, PROGRAMMING (beginning on Page 28).
MCUMicrocontroller Unit. This is the processor responsible for con-
trolling system start-up, synthesizer loading, hop timing, and key-up
control.
Microcontroller UnitSee MCU.
66 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
ModeThis refers to the programmed function of an MDS spread spec-
trum radiomaster or remote. (See also Remote Station and Master Sta-
tion.)
Multiple Address System (MAS)See Point-Multipoint System.
Network AddressUser-selectable number between 1 and 65000 that
is used to identify a group of transceivers that form a communications
network. The master and all remotes within a given system must have
the same network address.
Network-Wide DiagnosticsAn advanced method of controlling and
interrogating MDS radios in a radio network. It works by interspersing
diagnostic data with payload data.
Point-Multipoint SystemA radio communications network or
system designed with a central control station that exchanges data with
a number of remote locations equipped with terminal equipment.
PollA request for data issued from the host computer (or master PLC)
to a remote radio.
PLCProgrammable Logic Controller. A dedicated microprocessor
configured for a specific application with discrete inputs and outputs. It
can serve as a host or as an RTU.
Remote RadioA radio in a spread spectrum network that communi-
cates with an associated master station. A radio may be programmed for
either master or remote mode using software commands. See Section
6.0, PROGRAMMING (beginning on Page 28).
Remote Terminal UnitSee RTU.
RTURemote Terminal Unit. A data collection device installed at a
remote radio site.
SCADASupervisory Control And Data Acquisition. An overall term
for the functions commonly provided through an MAS radio system.
Standing Wave RatioSee SWR.
SWRStanding Wave Ratio. A parameter related to the ratio between
forward transmitter power and the reflected power from the antenna
system. As a general guideline, reflected power should not exceed 10%
of the forward power ( 2:1 SWR).
ZoneSee Frequency Zone.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide I-1
INDEX
A
ACCESS DENIED error message 31
Accessories (table) 7
ADDR command (set/display radio network address) 36
Alarm
checking for 51
code denitions 52
codes 51
codes, table 52
major vs. minor 51
output pin (Pin 25) 60
receiver timeout (RXTOT command) 43
reset output signal 36
set/display output sense (ASENSE command) 36
status (STAT command) 47
ALARM command (obsolete; see STAT command) 47
AMASK command (congure alarm output signal) 36
Antenna
installation 16
performance optimization 26
selection 11
SWR check 27
system gain vs. power output setting, table 14
system gain, dened 64
Yagi, illustrated 12
ASENSE command (set/display alarm output sense) 36
B
BAUD command (set/display data interface port attributes) 36
Baud rate
setting 28
setting for RJ-11 DIAG port (DLINK command) 54
Baud rate (diagnostics link) 39, 55
Bit, dened 64
BPS (bits-per-seond), dened 64
BUFF command (set/display received data handling mode) 37
Byte, dened 64
C
Cable
adapter, for connecting diagnostics PC to radio 54, 62
adapter, RJ-11 to DB-9 (illustrated) 54, 62
data equipment to DATA INTERFACE connector 16
data interface wiring for null-modem 23, 24
data interface wiring for peer-to-peer systems with repeater
assistance 21
data interface wiring for tail-end links 22
feedlines 12
HHT to radio (coiled cord) 28
local interface for repeater system 21
maximum length, recommended 17
null-modem, for repeater system 22, 23
null-modem, for same-site radios 54
power (positive/negative leads) 17
COMMAND FAILED error message 31
Commands
ADDR (set/display radio network address) 36
AMASK (congure alarm output signal) 36
ASENSE (set/display alarm output sense) 36
BAUD (set/display data interface port attributes) 36
BUFF (set/display received data handling mode) 37
CTS (set/display CTS line response timer) 37
CTSHOLD (set/display CTS hold timer) 38
detailed descriptions 3250
DEVICE (set/display DCE or CTS Key behavior) 38
display operating status 34
DLINK (set/display baud rate of diagnostics link) 39
DMGAP (set time to wait between characters) 39
DTYPE (set radios diagnopstics type) 39
entering on Hand-Held Terminal (HHT) 30
Hand-Held Terminal (HHT) 30
HOPTIME (set/display hoptime setting) 40
how used 35
INIT (restore factory default settings) 41
MODE (set/display master/remote operation) 41
most used 32, 35
network conguration 32, 54
OWM (set/display optional owners message) 42
OWN (set/display optional owners name) 42
PWR (set/display RF forward output power) 42
RSSI (display received signal strength) 42
RTU (enable/disable internal RTU) 43
RX (set/display test receive frequency) 43
RXTOT (set/display received data timeout value) 43
SEND (set/display number of re-sends) 43
set/program 33
SETUP (enter testing and setup mode) 44
SHOW (display active port, dc volts, measured power
output) 45
SIMPLEX (set/display simplex/half-duplex operation) 45
SKIP (set/display frequency zone to skip) 46
SKIPSYNC (set/display status of SYNC messages in
skipped zones) 46
SNR (display signal-to-noise ratio) 46
SREV (display transceiver software version) 47
STAT (list alarms) 47
summary, table 32
TDD (set/display time division multiplex status) 47
TEMP (display internal temperature) 48
CTS command (set/display CTS line response timer) 37
CTSHOLD command (set/display CTS hold timer) 38
D
Data buffer setting 27, 37
DATA INTERFACE
connections 58
connector pin descriptions, table 59
connector pins, illustrated 59
connector, RSSI vs. V dc at Pin 21 of (illustrated) 58
Data interface
cable wiring for peer-to-peer systems with repeater
assistance 21
cable wiring for repeater, illustrated 23, 24
cable wiring for tail-end links, illustrated 22
setting parameters 19
I-2 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
dBi, dened 64
dBm, dened 64
DCE, dened 64
Decibel (dB), dened 64
Default settings
data interface baud rate 28
factory settings reset by INIT command (table) 41
re-initializing HHT to 29
restoring (INIT command) 41
See also individual command descriptions
DEVICE command (set/display DCE or CTS Key
behavior) 38
Diagnostics
network-wide, performing 53
setup mode (SETUP command) 44
using InSite software for network-wide 53
Display
alarm output sense (ASENSE command) 36
alarms (STAT command) 47
connector port, diagnostics (SHOW command) 45
CTS hold timer value (CTSHOLD command) 38
CTS line response timer value (CTS command) 37
data interface baud rate (BAUD command) 36
dc input/output voltages (SHOW command) 45
device behavior (DEVICE command) 38
hoptime setting (HOPTIME command) 40
master or remote operation (MODE command) 41
network address (ADDR command) 36
operating status commands 34
owners message (OWM command) 42
owners name (OWN command) 42
received data handling mode (BUFF command) 37
received data timeout value (RXTOT command) 43
received signal strength (RSSI command) 42
RF forward output power (PWR command) 42
RF power output, actual measured (SHOW command) 45
signal-to-noise ratio (SNR command) 46
simplex or half-duplex operation (SIMPLEX command) 45
skipped frequency zones (SKIP command) 46
software version, transceiver (SREV command) 47
temperature, internal (TEMP command) 48
test receive frequency (RX command) 43
DKEY command (dekey transmitter) 27, 35, 45
DLINK command (set/display baud rate of diagnostics
link) 39, 54, 55
DMGAP command (set/display time to wait between
characters) 39
DSP (Digital Signal Processing), dened 64
DTE, dened 64
DTYPE command (set radios diagnostics type) 39, 54, 55
E
EEPROM FAILURE error message 32
Enable
diagnostics channel by grounding Pin 23 of HHT cable 29
HHT setup mode 29
internal RTU (RTU command) 43
master/remote operation (MODE command) 41
network-wide diagnostics, procedures 54
Setup mode (SETUP command) 44
simplex/half-duplex operation (SIMPLEX command) 45
skipped zone (SKIP command) 46
Sleep Mode 25
Equalization, dened 64
Error messages
on Hand-Held Terminal (HHT) 31
F
Fade margin, dened 65
Feedline
selection 11, 12
Frame, dened 65
Frequency hopping, dened 65
Frequency zone
dened 65
table 46
G
Gate (radio diagnostics type) 39, 55
Glossary 6366
H
Hand-Held Terminal (HHT)
command summary, table 32
connected to transceiver, illustrated 18, 29
connection and start-up 28
entering commands 30
error messages 31
keyboard commands 30
operational settings, table 30
re-initialization 29
setup display, illustrated 30
Hardware ow control, dened 65
Hopping, dened 65
Hoptime
parameters, table 40
setting 27
HOPTIME command (set/display hoptime setting) 40
Host computer, dened 65
I
Illustrations
antenna, Yagi 12
bench test setup 61
data interface cable wiring 21
data interface cable wiring for repeater 23, 24
data interface cable wiring for tail-end links 22
DATA INTERFACE connector pins 59
HHT connected to transceiver 18, 29
HHT setup display 30
LED status indicators 26
model conguration code 2
network-wide diagnostics 53
peer-to-peer network with repeater assistance 5, 20
point-to-point link 5
remote station arrangement 8
repeater system conguration 6
RJ-11 to DB-9 adapter 62
RJ-11 to DB-9 adapter cable 54
RSSI vs. V dc at Pin 21 of DATA INTERFACE
connector 58
simplex peer-to-peer network 4
tail-end link 6
transceiver 1
typical MAS network 3
INCORRECT ENTRY error message 31
INIT command (restore factory default settings) 41
InSite software 53
Installation 1425
antenna 16
conguring the transceiver 17
connecting transceiver to data equipment 16
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide I-3
feedline selection 12
peer-to-peer systems 19
performance optimization 26
primary power 17
programming network address 18
repeaters 22
requirements 7
setting data interface parameters 19
site selection 8
site survey 9
tail-end links 21
transmission path 8
Interference
about 10
checks 28
troubleshooting 56
K
Key
set to CTS keying (DEVICE command) 38
transmitter, for antenna SWR check 27
KEY command (key transmitter) 27, 35, 45
L
Latency, dened 65
LED status indicators
illustrated 26
table 26
M
Master Station
default settings 41
dened 65
MCU (Microcontroller Unit), dened 65
MDS Radio Conguration software 61
MODE command (set/display master/remote operation) 41
Mode, dened 66
Model conguration code, illustrated 2
Mounting instructions 15
Multiple Address System (MAS)
dened 65
network, illustrated 3
N
Network address
dened 66
programming 18
Network conguration commands 32, 54
Network-wide diagnostics
dened 66
illustrated 53
procedures 53
Node (radio diagnostics type) 39, 55
NOT AVAILABLE error message 31
NOT PROGRAMMED error message 31
O
Operation 2628
OWM command (set/display optional owners message) 42
OWN command (set/display optional owners name) 42
P
PASSWORD INVALID error message 31
PC
connecting to radio for software upgrade 62
connecting to radios diagnostic port 54
launching InSite application at 55
performing diagnostics using connected 53
Peer (radio diagnostics type) 39, 55
Peer-to-peer network
installation 19
with repeater assistance, illustrated 5, 20
Performance optimization 26
Pins, DATA INTERFACE connector descriptions (table) 59
PLC (Programmable Logic Controller), dened 66
Point-to-multipoint system
dened 66
power usage 13
Point-to-point system
link, illustrated 5
Poll, dened 66
Power
how much can be run 13
measuring and installing primary 17
set/display RF forward output (PWR command) 42
sleep mode 25
Procedures
antenna aiming 27
antenna and feedline selection 11
antenna SWR check 27
conguring the transceiver 17
connecting data equipment to DATA INTERFACE
connector 16
connecting PC and radios for network-wide diagnostics 54
enabling sleep mode 25
entering commands using Hand-Held Terminal (HHT) 30
Hand-Held Terminal (HHT) connection and start-up 28
Hand-Held Terminal (HHT) set-up 29
installation 1425
installation planning 7
installing the antenna and feedline 16
interference check 28
measuring and installing primary power 17
mounting the transceiver 15
network-wide diagnostics 53
performance optimization 26
performing network-wide diagnostics 53
programming radio for network-wide diagnostics 54
programming the radio 2832
reading LED status indicators 26
site selection 8
troubleshooting 5056
Programming radio 2850
as root or node 54
PWR command (set/display RF forward output power) 42
R
Radio
bench test setup, illustrated 61
bench testing setup 61
checking RSSI with voltmeter 58
connecting PC to (for software upgrade) 62
inoperative (troubleshooting chart) 56
no synchronization with master (troubleshooting chart) 56
poor performance (troubleshooting chart) 56
Remote radio
default settings 41
dened 66
Remote station
typical arrangement, illustrated 8
Repeater
I-4 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
data interface cable wiring for, illustrated 23, 24
installation 22
installing peer-to-peer with 20
system, illustrated 6
using single radio for 24
Root (radio diagnostics type) 39, 55
RSSI
checking with voltmeter 58
RSSI command (display received signal strength) 42
RTU (Remote Terminal Unit)
dened 66
simulator (used in test setup) 61
RTU command (enable/disable internal RTU) 43
RX command (set/display test receive frequency) 43
RXTOT command (set/display received data timeout
value) 43
S
SCADA (Supervisory Control and Data Acquisition),
dened 66
SEND command (set/display number of re-sends) 43
Set
alarm output sense (ASENSE command) 36
alarm output signal (AMASK command) 36
CTS hold timer (CTSHOLD command) 38
CTS line response timer (CTS command) 37
data interface baud rate (BAUD command) 36
DCE or CTS Key device behavior (DEVICE command) 38
frequency zone to skip (SKIP command) 46
hoptime (HOPTIME command) 40
master/remote operation (MODE command) 41
network address (ADDR command) 36
owners message (OWM command) 42
owners name (OWN command) 42
received data handling mode (BUFF command) 37
received data timeout value (RXTOT command) 43
simplex or half-duplex operation (SIMPLEX command) 45
test receive frequency (RX command) 43
testing mode (SETUP command) 44
Set/program commands 33
SETUP command (enter testing and setup mode) 44
SHOW command (display active port, dc volts, measured
power output) 45
Simplex
installing peer-to-peer system 19
peer-to-peer network, illustrated 4
SIMPLEX command (set/display simplex/half-duplex
operation) 45
Single-radio repeater 24
Site selection 8
SKIP command (set/display frequency zone to skip) 46
SKIPSYNC (set/display status of SYNC messages in skipped
zones) 46
Sleep mode 25
SNR command (display signal-to-noise ratio) 46
Software
cable connection for upgrade 62
radio conguration 61
SREV command (display transceiver software version) 47
STAT command (list alarms) 47
SWR (Standing Wave Ratio)
dened 66
performance optimization 27
T
Tables
accessories 7
alarm codes 52
antenna system gain vs. power output setting 14
DATA INTERFACE connector pin descriptions 59
frequency zones 46
Hand-Held Terminal (HHT) command summary 32
HHT operational settings 30
hop time parameters 40
LED status indicators 26
troubleshooting 56
Tail-end link
cable wiring for, illustrated 22
illustrated 6
installation 21
TDD (set/display time division multiplex status) 47
Technical reference 5663
Technical specications 5658
TEMP command (display internal temperature) 48
Temperature, display internal (TEMP command) 48
Testing
bench setup 61
bench setup, illustrated 61
TEXT TOO LONG error message 31
Transceiver
conguring 17
connected to HHT, illustrated 18
connecting to data equipment 16
default settings 41
HHT connected to, illustrated 29
illustrated 1
mounting instructions 15
performance optimization 26
sleep mode 25
Troubleshooting 5056
performing network-wide diagnostics 53
table 56
U
UNKNOWN COMMAND error message 31
IN CASE OF DIFFICULTY...
MDS products are designed for long life and trouble-free operation. However, this equipment, as
with all electronic equipment, may have an occasional component failure. The following informa-
tion will assist you in the event that servicing becomes necessary.
TECHNICAL ASSISTANCE
Technical assistance for MDS products is available from our Technical Support Department during
business hours (8:00 A.M.5:30 P.M. Eastern Time). When calling, please give the complete
model number of the radio, along with a description of the trouble/symptom(s) that you are expe-
riencing. In many cases, problems can be resolved over the telephone, without the need for
returning the unit to the factory. Please use one of the following means for product assistance:
Phone: 585 241-5510 E-Mail: [email protected]
FAX: 585 242-8369 Web: www.microwavedata.com
FACTORY SERVICE
Component level repair of radio equipment is not recommended in the field. Many components are
installed using surface mount technology, which requires specialized training and equipment for
proper servicing. For this reason, the equipment should be returned to the factory for any PC board
repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating
specifications.
If return of the equipment is necessary, you will be issued a Service Request Order (SRO) number.
The SRO number will help expedite the repair so that the equipment can be repaired and returned
to you as quickly as possible. Please be sure to include the SRO number on the outside of the ship-
ping box, and on any correspondence relating to the repair. No equipment will be accepted for
repair without an SRO number.
A statement should accompany the radio describing, in detail, the trouble symptom(s), and a
description of any associated equipment normally connected to the radio. It is also important to
include the name and telephone number of a person in your organization who can be contacted if
additional information is required.
The radio must be properly packed for return to the factory. The original shipping container and
packaging materials should be used whenever possible. All factory returns should be addressed to:
Microwave Data Systems
Product Services Department
(SRO No. XXXX)
175 Science Parkway
Rochester, NY 14620 USA
When repairs have been completed, the equipment will be returned to you by the same shipping
method used to send it to the factory. Please specify if you wish to make different shipping arrange-
ments. To inquire about an in-process repair, you may contact our Product Services Group at
585-241-5540 (FAX: 585-242-8400), or vie e-mail at [email protected].
Microwave Data Systems Inc.
Rochester, NY 14620
General Business: +1 585 242-9600
FAX: +1 585 242-9620
Web: www.microwavedata.com
175 Science Parkway
A product of Microwave Data Systems Inc.

You might also like