This document is a project completion report for a solar power plant between 1-100kWp that was installed. It provides details on the site location, system components installed including the capacity, modules, PCU, batteries, structure, cables and distribution. It also includes generation/consumption data, inspection details verifying the installation matches what was proposed, and signatures from the user, installer and inspecting officer approving the project.
This document is a project completion report for a solar power plant between 1-100kWp that was installed. It provides details on the site location, system components installed including the capacity, modules, PCU, batteries, structure, cables and distribution. It also includes generation/consumption data, inspection details verifying the installation matches what was proposed, and signatures from the user, installer and inspecting officer approving the project.
Project completion Report for Solar Power Plants (1-100kWp)
Part-A (by the installer)
S No Component Observation 1 Sanction No & Date
2 Category :-Nodal Agency/ Channel partner (Name) and Complete Address
Site/ Location with Complete Address
Longitude/ Latitude 3 Capacity of system installed(kWp)
4 Specification of the Modules Type of modules(multi/mono) Make of Modules and year of manufacturing
Wattage and no of modules Module Efficiency No of series &Parallel combinations
Tilt Angle of Modules 4.1 IEC certificate Date of issue Agency Validity Enclose a IEC certificate
4.2 Whether imported or indigenous. 4.3 RFID tag is pasted inside or outside
4.4 Type of RFID
5 PCU Make,& rating Type of Charge controller/MPPT
Capacity of inverter and year of manufacturing
AC Output Whether hybrid or stand alone Whether indigenous or imported Enclose test certificate as per MNRE requirement
Input Voltage to Inverter
6
Batteries Make of batteries and year of manufacturing
Type : Tubular Lead Acid /VRLA/GEL
Rating and no. No of series and parallel combinations
Enclose test certificate as per MNRE requirement
7 Depth of Discharge Proposed Autonomy (Days) 8 Structures Tracking or non tracking Indigenous or imported 9 Cables Make and size Enclose Certificate: Rating :-
voltage of cable
10
Distribution Box Name Make Certificate
11 Earthling and protections Lightening Arrester (Type)
12 Date of Commissioning 13 Enclose Generation data for one month ( for without battery systems )
13a. Enclose energy consumption data for one month ( for battery based systems)
14 Monitoring Mechanism for the installed System
Technical Person Trained to maintain system Name with Mobile no.
Declaration It is to certify that all the components/subsystems and materials including junction boxes, cables, distribution boards. switches, circuit barkers used are as per MNRE requirement and as per DPR submitted. (Channel Partner/SNA ) With seal Date: Place: PART-B ( By the customer) S No Component Observation 1 Name of the customer 2 Location Capacity (kWp) Location 3 Whether training was provided by installer for operation and maintenance
4 Whether the following documents were provided or not
I-V curves of all modules Inverter manual Warranty card for system 5 Date of handing over of the system
6 Cost breakup Total project cost: User Share: MNRE share: User payment (Only cheques are allowed) Cheque No. & date
It is to certify that all information given above is true and correct to best of my knowledge
(User signature and stamp) Date and place PART-C Inspection report (by inspecting Officer)
S No Component Observation 1 Site/ Location with Complete Address
2 Capacity of system installed(kWp)
3 Whether the system was installed in shadow free area or not? If not mention the details
Gap between rows of the modules
Any inter module shading exists or not
Whether the modules contains information about company name, serial no and year manufacturing inside
RIFD pasted inside or outside
4 PCU
Whether the information given in part A is same or found any deviation
5
Batteries
Whether the information given in part A is same or found any deviation
6 Structures
7 Cables Make and size
8
Distribution Box
9 Earthling and protections
10 Cumulative generation data at the date of visit or cumulative energy consumption data at the time of visit
11 User Feed Back
12 Any specific problem
1. Signature of User With Stamp and date
2. Channel partner signature with stamp and date
3. Signature of inspecting Officer and date
List of enclosures:
1. Copy of invoice billed to user 2. List of serial no. of modules and batteries installed in the system 3. Test certificates of the components 4. Statement of Expenditure 5. Original Color photographs