0% found this document useful (0 votes)
63 views

Cisco SBA DC UnifiedComputingSystemDeploymentGuide

Cisco(r) Smart Business Architecture (sba) guides are for people who fill a variety of roles. Cisco strives to update and enhance sba guides on a regular basis. To ensure mutual compatibility, you should use guides that belong to the same series.

Uploaded by

Sa Ku
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views

Cisco SBA DC UnifiedComputingSystemDeploymentGuide

Cisco(r) Smart Business Architecture (sba) guides are for people who fill a variety of roles. Cisco strives to update and enhance sba guides on a regular basis. To ensure mutual compatibility, you should use guides that belong to the same series.

Uploaded by

Sa Ku
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 79

February 2013 Series

Unied Computing System


Deployment Guide
Preface
Who Should Read This Guide
This Cisco Smart Business Architecture (SBA) guide is for people who fill a
variety of roles:
Systems engineers who need standard procedures for implementing
solutions
Project managers who create statements of work for Cisco SBA
implementations
Sales partners who sell new technology or who create implementation
documentation
Trainers who need material for classroom instruction or on-the-job
training
In general, you can also use Cisco SBA guides to improve consistency
among engineers and deployments, as well as to improve scoping and
costing of deployment jobs.
Release Series
Cisco strives to update and enhance SBA guides on a regular basis. As
we develop a series of SBA guides, we test them together, as a complete
system. To ensure the mutual compatibility of designs in Cisco SBA guides,
you should use guides that belong to the same series.
The Release Notes for a series provides a summary of additions and
changes made in the series.
All Cisco SBA guides include the series name on the cover and at the
bottom left of each page. We name the series for the month and year that we
release them, as follows:
month year Series
For example, the series of guides that we released in February 2013 is
the February Series.
You can find the most recent series of SBA guides at the following sites:
Customer access: http: //www.cisco.com/go/sba
Partner access: http: //www.cisco.com/go/sbachannel
How to Read Commands
Many Cisco SBA guides provide specific details about how to configure
Cisco network devices that run Cisco IOS, Cisco NX-OS, or other operating
systems that you configure at a command-line interface (CLI). This section
describes the conventions used to specify commands that you must enter.
Commands to enter at a CLI appear as follows:
configure terminal
Commands that specify a value for a variable appear as follows:
ntp server 10.10.48.17
Commands with variables that you must define appear as follows:
class-map [highest class name]
Commands shown in an interactive example, such as a script or when the
command prompt is included, appear as follows:
Router# enable
Long commands that line wrap are underlined. Enter them as one command:
wrr-queue random-detect max-threshold 1 100 100 100 100 100
100 100 100
Noteworthy parts of system output or device configuration files appear
highlighted, as follows:
interface Vlan64
ip address 10.5.204.5 255.255.255.0
Comments and Questions
If you would like to comment on a guide or ask questions, please use the
SBA feedback form.
If you would like to be notified when new comments are posted, an RSS feed
is available from the SBA customer and partner pages.
Preface February 2013 Series
Table of Contents February 2013 Series
Whats In This SBA Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Cisco SBA Data Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Route to Success . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Business Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Deployment Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Data Center Core Network Infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Configuring the Ethernet Network Infrastructure . . . . . . . . . . . . . . . . . . . . 9
Configuring the Fibre Channel or FCoE Network Infrastructure . . . . 11
Cisco UCS B-Series Blade Server System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Completing the Initial System Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Configuring Communications Connections Using UCS Manager . . 19
Configuring Common System Address Pools and VLANs . . . . . . . . . . 30
Configuring Virtual Adapter Templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Configuring Server Boot Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Creating an Initial Boot Service Profile for Local Boot . . . . . . . . . . . . . . 44
Creating a Service Profile for SAN Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Creating Multiple Service Profiles through Templates . . . . . . . . . . . . . . 50
Cisco UCS C-Series Rack-Mount Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Configuring Cisco Integrated Management Controller . . . . . . . . . . . . . 53
Configuring LSI RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Updating Firmware for Cisco UCS C-Series Server . . . . . . . . . . . . . . . . 57
Configuring Ethernet and FCoE Connectivity . . . . . . . . . . . . . . . . . . . . . . 62
Integrating Cisco UCS C-Series into the Cisco UCS Manager
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Appendix A: Product List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Appendix B: Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Table of Contents
About This Guide
This deployment guide contains one or more deployment chapters, which
each include the following sections:
Business OverviewDescribes the business use case for the design.
Business decision makers may find this section especially useful.
Technology OverviewDescribes the technical design for the
business use case, including an introduction to the Cisco products that
make up the design. Technical decision makers can use this section to
understand how the design works.
Deployment DetailsProvides step-by-step instructions for deploying
and configuring the design. Systems engineers can use this section to
get the design up and running quickly and reliably.
You can find the most recent series of Cisco SBA guides at the following
sites:
Customer access: http: //www.cisco.com/go/sba
Partner access: http: //www.cisco.com/go/sbachannel
Whats In This SBA Guide
Cisco SBA Data Center
Cisco SBA helps you design and quickly deploy a full-service business
network. A Cisco SBA deployment is prescriptive, out-of-the-box, scalable,
and flexible.
Cisco SBA incorporates LAN, WAN, wireless, security, data center, application
optimization, and unified communication technologiestested together as a
complete system. This component-level approach simplifies system integration
of multiple technologies, allowing you to select solutions that solve your
organizations problemswithout worrying about the technical complexity.
Cisco SBA Data Center is a comprehensive design that scales from a server
room to a data center for networks with up to 10,000 connected users. This
design incorporates compute resources, security, application resiliency, and
virtualization.
Route to Success
To ensure your success when implementing the designs in this guide, you
should first read any guides that this guide depends uponshown to the
left of this guide on the route below. As you read this guide, specific
prerequisites are cited where they are applicable.
1
Whats In This SBA Guide February 2013 Series
Data Center
Design Overview
Unified Computing System
Deployment Guide
Additional Deployment
Guides
Data Center
Deployment Guide
DATA
CENTER
You Are Here Dependent Guides Prerequisite Guides
22
Introduction February 2013 Series
Introduction
This Unified Computing System Deployment Guide builds upon the foun-
dation laid out in the Cisco SBAData Center Deployment Guide.
This guide includes the following modules:
The first module explains how to program the foundation data center
for connectivity to the Cisco UCS B-Series Blade Server system for
maximum throughput and resiliency. This module covers Ethernet, Fibre
Channel, and Fibre Channel over Ethernet connections between the
UCS B-Series Blade Server system and the data center core network
deployed in the Data Center Deployment Guide.
The Cisco UCS B-Series Blade Server system module shows how the
system is programmed from the ground up to a point where the bare
metal server is ready for an operating system or hypervisor software
installation. This module shows how the Cisco Unified Computing
System Manager (UCS Manager) is used to program all elements of the
systemfrom connectivity to the data center core, to building profiles
to assign the various aspects of the server boot, communications, and
storage to the physical blade server hardware.
The Cisco UCS C-Series Rack-Mount Server module shows how to use
the Cisco Integrated Management Controller (CIMC) to remotely config-
ure and prepare a server to a point where it is ready to load an operating
system or hypervisor software. Similar to the Cisco UCS B-Series Blade
Server system module, this section shows how to establish connectivity
to the data center core to support Ethernet and Fibre Channel com-
munications by using converged network adapters that add flexibility
to server connectivity and reduce cabling and complexity. This module
also includes guidance on managing the UCS C-Series server with the
same Cisco UCS Manager that controls the B-Series servers for a single
method of managing both server types.
The appendices provide the complete list of products used in the lab
testing of this architecture, as well as the software revisions used on the
products and a list of major changes since the last edition of this guide.
Business Overview
As an organization begins to grow, the number of servers required to
handle the information-processing tasks of the organization grows as well.
Using the full capabilities of the investment in server resources can help an
organization add new applications while controlling costs as they move from
a small server room environment to a more scalable data center design.
Server virtualization has become a common approach to allow an organiza-
tion to access the untapped processing capacity available in processor
technology. Streamlining the management of server hardware and its
interaction with networking and storage equipment is another important
component of using this investment in an efficient manner.
Scaling a data center with conventional servers, networking equipment, and
storage resources can pose a significant challenge to a growing organiza-
tion. Multiple hardware platforms and technologies must be integrated to
deliver the expected levels of performance and availability to application
end users. These components in the data center also need to be managed
and maintained, typically with a diverse set of management tools that have
different interfaces and approaches. In larger organizations, often multiple
teams of people are involved in managing applications, servers, storage, and
networking. In many smaller organizations, the lines between these tasks
are blurred, and often a single, smaller teamor even one individualmay
need to handle many of these tasks in a day.
Business agility in the data center is a growing concern for organizations.
The ability to reduce the time necessary to deploy new applications or
expand existing applications to a larger footprint to handle increasing
workloads contributes to the success of a project. The compute environment
needs to be consistent to reduce operational requirements, yet flexible to
accommodate the different requirements of applications and the operating
system.
Application availability is key to an organization. Users depend on reaching
the systems and information that are required to run the business just as
much as they depend on having lights in the office or a power outlet to plug
in a PC.
3
Introduction February 2013 Series 3
Technical Overview
Consistent with the Cisco Smart Business Architecture (SBA) approach,
Cisco offers a simplified reference model for managing a small server room
as it grows into a full-fledged data center. This model benefits from the ease
of use offered by the Cisco Unified Computing System. This guide has been
lab-tested in conjunction with the architecture defined in the Cisco SBA
Data Center Deployment Guide, available at: www.cisco.com/go/sba.
This guide addresses many of the same business issues encountered by
growing organizations, issues that are identified in the Cisco SBAData
Center Deployment Guide, but it focuses on the server resources them-
selves and their interaction with network and storage systems.
Application Growth
The Cisco SBA Unified Computing System model provides for using a
simple GUI for rapid deployment of additional physical servers that share
common attributes. Using the Cisco UCS Manager service profiles, you can
define the personality of an individual serverincluding boot characteris-
tics, interface addresses, and even firmware versionsseparately from any
physical hardware. You can also generate service profiles from a template
and keep them linked to the template to facilitate updates across multiple
servers in the future. This gives you the ability to create a new server by
cloning an existing service profile or using a template. It also means that it
only takes a few minutes to deploy a new server, and you can limit physical
server hardware to a flexible and common pool of spare parts as your data
center grows.
Increasing Storage Requirements
The most efficient way to manage the investment in additional storage
capacity is to move to a centralized storage model. The Cisco SBA Unified
Computing System model decouples the computing functions of the server
farm from the storage systems, which provides greater flexibility for system
growth and migration. System storage and boot disk are accessible from
either the local disk that is available on each server or through access to
centralized storage located on the Ethernet IP network or Fibre Channel or
Fibre Channel over Ethernet storage area network (SAN).
Managing Processing Resources
Some applications require enough processing and memory that you might
decide to dedicate an entire server or even a cluster of servers to support
the workload. Other applications may start out on a single server where the
processor and memory are underutilized, resulting in excess or wasted
resources. In the case where applications need a separate operating
environment but not an entire server for processing and memory resources,
server virtualization is the key to combining applications and optimizing
resources. Server virtualization technologies insert a hypervisor layer
between the server operating systems and the hardware, allowing a single
physical server to run multiple instances of different guest operating
systems such as Microsoft Windows or Linux. This increases the utilization
of the processors on the physical servers, which helps to optimize this costly
resource.
The architecture of the Cisco SBA Unified Computing System model is
optimized to support the use of hypervisor-based systems or the direct
installation of a base operating system such as Windows or Linux. The ser-
vice profile structure of Cisco UCS, along with a centralized storage model,
allows you the portability of server definitions to different hardware with or
without a hypervisor system in place. Built on the data center infrastructure
foundation defined in Cisco SBAData Center Deployment Guide, the
Cisco SBA Unified Computing System model provides scalable connectivity
options for not only Cisco UCS Series 5100 Blade Server Chassis but also
Cisco UCS C-Series Rack-Mount Servers, as well as connectivity options to
support third-party servers.
Availability and Business Continuance
The Cisco SBA data center foundation has been designed to ensure avail-
ability with the use of resilient network devices, links, and service models.
The Cisco SBA Unified Computing System model extends this resiliency to
the servers themselves through the capabilities of Cisco Unified Computing
System.
Cisco Unified Computing System uses service profiles to provide a
consistent interface for managing all server resource requirements as a
logical entity, independent of the specific hardware module that is used to
provide the processing capacity. This service profile approach is applied
consistently on both virtualized servers and bare metal servers, which do
not run a hypervisor. This capability allows the entire personality of a given
logical server to be ported easily to a different physical server module
independent of any virtualization software when LAN or SAN boot are in use.
This approach increases overall availability and dramatically reduces the
time required to replace the function of an individual server module that has
failed.
4
Introduction February 2013 Series 4
Figure 1 - Cisco SBA Unified Computing System architecture
This architecture is designed to allow your existing server farm to migrate
into a scalable Ethernet and storage transport based on the Cisco SBA
reference design. Figure 1 shows the data center components of this archi-
tecture and their interaction with the Cisco SBA headquarters LAN core.
Ethernet Foundation
The Cisco SBAUnified Computing System Deployment Guide is
designed as an extension of the Cisco SBAData Center Deployment
Guide. The basis of the Cisco SBA Unified Computing System architecture
is an Ethernet switch fabric that consists of two Cisco Nexus 5500UP
switches, as shown in Figure 1. This data center switching fabric provides
Layer 2 and Layer 3 Ethernet switching services to attached devices and, in
turn, communicates with the Cisco SBA LAN Ethernet core by using redun-
dant Layer 3 links.
The two Cisco Nexus 5500UP switches form the Ethernet switch fabric
using Virtual Port Channel (vPC) technology. This feature provides loop-
prevention services and allows the two switches to appear as one logical
Layer-2 switching instance to attached devices. In this way, the Spanning
Tree Protocol, which is a standard component of Layer-2 bridging, does
not need to block any of the links in the topology to prevent bridging loops.
Additional Gigabit Ethernet and 10-Gigabit Ethernet switch port density
may be added to the switch fabric by using Cisco Nexus 2000 Series Fabric
Extenders. The vPC and fabric extender technologies provide the flex-
ibility for extending VLANs across the data center for a resilient, virtualized
computing environment.
Storage Networking
The Cisco SBA Unified Computing System model is also adaptable to
multiple ways of accessing centralized storage. Two alternatives for storage
access are included in the overall architecture. One approach uses a pure
Ethernet IP network to connect the servers to both their user community and
the shared storage array. Communication between the servers and storage
over IP can be accomplished by using an Internet Small Computer System
Interface (iSCSI), which is a block-oriented protocol encapsulated over IP,
or traditional network-attached storage (NAS) protocols such as Common
Internet File System (CIFS) or network file server (NFS). LAN-based storage
access follows the path through the Cisco Nexus 5500 Series Switching
Fabric shown in Figure 1.
A more traditional but advanced alternative for providing shared storage
access is using a Fibre Channel SAN built using the data center core Cisco
Nexus 5500UP switches or the Cisco MDS 9100 Series for larger SAN
environments. Fibre Channel over Ethernet (FCoE) builds on the lossless
Ethernet infrastructure to provide a converged network infrastructure.
For resilient access, SANs are normally built with two distinct fabric
switches that are not cross-connected. Currently, Fibre Channel offers
the widest support for various disk-array platforms and also support for
boot-from-SAN.
The Cisco UCS 6200 Series Fabric Interconnects also maintain separate
Fibre Channel fabrics, so each fabric is attached to one of the data center
core switches running either SAN A or SAN B as shown in Figure 2. When
Fibre Channel is used for storage access from Cisco UCS B-Series Blade
Servers, the system provides virtual host bus adapters (vHBAs) to the
service profiles to be presented to the host operating system. The Cisco
UCS fabric interconnect can now connect to the data center core switches
with FCoE uplinks as of Cisco UCS Manager release 2.1(1a). This guide will
show how you can use Fibre Channel or FCoE uplinks from the Cisco UCS
fabric interconnect to the data center core switches.
5
Introduction February 2013 Series 5
Figure 2 - Cisco UCS 6200 fabric interconnect to SAN core
On the Cisco UCS fabric interconnect, the Fibre Channel ports that connect
to the data center core SAN operate in N-port Virtualization mode. All Fibre
Channel switching happens upstream at the data center core switches
running N-Port Identifier Virtualization (NPIV). NPIV allows multiple Fibre
Channel port IDs to share a common physical port. Though there are mul-
tiple Fibre Channel ports on the fabric interconnects, local Fibre Channel
switching between these ports is not covered in this guide.
You can connect the Cisco UCS C-Series Rack-Mount Servers to the Fibre
Channel SAN by using dedicated host bus adapters (HBAs) that attach
directly to the SAN switches. Alternately, you can use a converged network
adapter, which allows Ethernet data and Fibre Channel over Ethernet (FCoE)
storage traffic to share the same physical set of cabling. This Unified Wire
approach allows these servers to connect directly to the Cisco Nexus
5500UP Series switches or a Cisco Nexus Fabric Extender for data traffic, as
well as SAN A and SAN B highly available storage access, shown in Figure
3. The Cisco Nexus 5500UP switch fabric is responsible for splitting FCoE
traffic off to the Fibre Channel attached storage array. Many storage arrays
now include FCoE connectivity as an option and can be directly connected
to the data center core.
Figure 3 - Cisco UCS C-Series server to SAN core using FCoE
Many available shared storage systems offer multi-protocol access to the
system, including iSCSI, Fibre Channel, FCoE, CIFS, and NFS. Multiple
methods can be combined on the same storage system to meet the access
requirements of a variety of server implementations. This flexibility also
helps facilitate migration from legacy third-party server implementations
onto Cisco UCS.
6
Introduction February 2013 Series 6
Computing Systems
The primary computing platforms targeted for the Cisco SBA Unified
Computing System reference architecture are Cisco UCS B-Series Blade
Servers and Cisco UCS C-Series Rack-Mount Servers.
The Cisco UCS 5100 Series Blade Server Chassis is a blade-server style
enclosure supporting compact, slide-in server modules, but architecturally
it is a significantly different approach from traditional blade-server systems
on the market. Most blade server systems essentially take the components
that would have been in a standalone data center rack, such as a number
of standardized rack-mount servers with a pair of redundant top-of-rack
switches, and attempt to condense them into a single sheet-metal box.
Some of these implementations even include localized storage arrays within
the chassis. That approach achieves higher system density but retains most
of the complexity of traditional rack systems in a smaller form factor. Also,
the number of management interfaces and switching devices multiplies with
each new chassis.
By extending a single low-latency network fabric directly into multiple
enclosures, Cisco has removed the management complexity and cable-
management issues associated with blade switching or pass-through mod-
ule implementations common to blade servers. By consolidating storage
traffic along this same fabric using lossless FCoE technology, Cisco UCS
even further simplifies the topology by using the fabric interconnects as a
common aggregation point for Ethernet data traffic and storage-specific
Fibre Channel traffic. On top of this vastly simplified physical architecture,
Cisco UCS Manager extends a single management interface across the
physical blade servers and all of their associated data and storage network-
ing requirements. The Cisco UCS Manager can also extend the single
management interface to Cisco UCS C-Series servers when those servers
are interconnected to the UCS Fabric Interconnects.
Cisco Unied Computing System Components
The Cisco Unified Computing System has a unique architecture that
integrates compute, data network access, and storage network access into
a common set of components under a single-pane-of-glass management
interface. The primary components included within this architecture are as
follows:
Cisco UCS Fabric InterconnectThe Cisco UCS 6200 Series fabric
interconnects provide both network connectivity and management
capabilities to the other components in the system. It is recommended
that the fabric interconnects are clustered together as a pair, providing
resilient management accessas well as 10-Gb Ethernet, Fibre
Channel, and FCoE capabilitiesto the system. The Cisco UCS 6200
fabric interconnect provides the flexibility of unified ports, enabling a
port to run Ethernet or Fibre Channel.
Cisco UCS Fabric ExtenderThe Cisco UCS 2200 Series Fabric
Extenders, also referred to as I/O modules, are installed directly within
the Cisco UCS 5100 Series Blade Server Chassis enclosure. These
modules logically extend the fabric from the fabric interconnects into
each of the enclosures for Ethernet, FCoE, and management purposes.
The fabric extenders simplify cabling requirements from the blade serv-
ers installed within the system chassis.
Cisco UCS 5100 Series Blade Server ChassisThe Cisco UCS 5100
Series Blade Server Chassis provides an enclosure to house up to
eight half-width or four full-width blade servers, their associated fabric
extenders, and four power supplies for system resiliency.
As of Cisco UCS release 2.1(1a), a single pair of fabric intercon-
nects may connect to and manage up to twenty Cisco UCS 5100
Series Blade Server Chassis.
Tech Tip
Cisco UCS B-Series Blade ServersCisco B-Series Blade Servers
implement Intel Xeon Series processors and are available in both a half-
width or full-width format. The Cisco UCS B22, B200, and B230 blade
servers require a half-slot within the enclosure, providing high-density,
high-performance computing resources in an easily managed system.
The Cisco UCS B250, B420, and B440 blade servers require a full slot
and offer extended memory, increased processing power, increased
local storage, and higher I/O throughput.
Cisco UCS B-Series Network AdaptersThe Cisco UCS B-Series
Blade Servers accept a variety of mezzanine adapter cards that allow
the switching fabric to provide multiple interfaces to a server. These
adapter cards fall into three categories:
Ethernet adaptersThe baseline 10-Gigabit Ethernet adapters can
present up to two Ethernet interfaces to a server.
Converged network adaptersCisco converged network adapt-
ers are available in multiple models, with chip sets from multiple
7
Introduction February 2013 Series 7
manufacturers to meet specific needs. These adapters can present
up to two 10-Gigabit Ethernet interfaces to a server, along with two
Fibre Channel interfaces.
Virtual interface cardsThe Cisco virtual interface cards (VICs)
feature new technology from Cisco, allowing additional network
interfaces to be dynamically presented to the server. This adapter
supports Cisco VN-Link technology in hardware, which allows each
virtual adapter to appear as a separate virtual interface on the fabric
interconnects. The architecture of the VIC is capable of support-
ing up to 256 total virtual interfaces split between virtual network
interface cards (vNICs) and vHBAs. The number of virtual interfaces
currently supported depends on the UCS infrastructure, including
the fabric interconnect, I/O module, VIC model, and version of Cisco
UCS Manager.
Cisco UCS Manager
Cisco UCS Manager is embedded software that resides on the fabric
interconnects, providing complete configuration and management capabili-
ties for all of the components in the Cisco UCS system. This configuration
information is replicated between the two fabric interconnects, providing a
highly available solution for this critical function. The most common way to
access UCS Manager for simple tasks is to use a Web browser to open the
Java-based GUI. For command-line or programmatic operations against the
system, a command-line interface (CLI) and an XML API are also included
with the system.
The Cisco UCS Manager GUI provides role-based access control (RBAC)
to allow multiple levels of users granular administrative rights to system
objects. Users can be restricted to certain portions of the system based on
locale, which corresponds to an optional organizational structure that can
be created within the system. Users can also be classified based on their
access levels or areas of expertise, such as Storage Administrator, Server
Equipment Administrator, or Read-Only. RBAC allows the comprehensive
capabilities of the Cisco UCS Manager GUI to be properly shared across
multiple individuals or teams within your organization in a flexible, secure
manner.
Cisco UCS Manager provides unified, embedded management of all soft-
ware and hardware components. Every instance of Cisco UCS Manager and
all of the components managed by it form a domain. For organizations that
deploy multiple Cisco UCS domains, Cisco UCS Central software provides
a centralized user interface that allows you to manage multiple, globally
distributed Cisco UCS domains with thousands of servers. Cisco UCS
Central integrates with Cisco UCS Manager and utilizes it to provide global
configuration capabilities for pools, policies, and firmware.
Cisco UCS C-Series Rack-Mount Servers
Cisco UCS C-Series servers extend Cisco Unified Computing System inno-
vations and benefits to the rack-mount server form factor. Designed to oper-
ate in a standalone environment or as part of the Cisco Unified Computing
System, Cisco UCS C-Series servers can be used to satisfy smaller regional
or remote office requirements, or they can be used as an approach to
deploy rack-mounted servers on an incremental basis. The Cisco UCS
C-Series servers also implement Intel Xeon processor technology and are
available in multiple models with options for processing power, local storage
size, and I/O throughput requirements. They offer Cisco innovations such as
extended memory and network-aware VN-Link technologies.
The Cisco Integrated Management Controller (CIMC) is the management
service for Cisco C-Series servers. CIMC runs within the server and allows
you to use a web-based GUI or Secure Shell (SSH) Protocolbased CLI to
access, configure, administer, and monitor the server. Almost all tasks can
be performed in either interface, and the results of tasks performed in one
interface are displayed in the other. You can use CIMC to perform the follow-
ing server management tasks, including (but not limited to):
Power on, power off, power cycle, reset, and shut down the server
Configure the server boot order
View server properties and sensors
Configure network-related settings, including network interface card
(NIC) properties and network security
Configure communication services, including HTTP, SSH, SNMP, and
Intelligent Platform Management Interface (IPMI) over LAN
Update CIMC firmware
Monitor faults, alarms, and server status
8
Introduction February 2013 Series 8
The Cisco UCS C-Series servers can be managed by the Cisco UCS
Manager if they are deployed connected to the fabric interconnects via
Cisco 2232PP fabric extenders as shown in Figure 4. This type of deploy-
ment enables the flexibility of both rack-mounted and blade servers with
a single-pane-of-glass management of all Cisco UCS servers in the data
center. The newer Cisco UCS C-Series M3 model servers can be managed
with a single wire connected to the Cisco 2232PP fabric extenders when the
server is using the new Cisco UCS VIC 1225 virtual interface card.
Figure 4 - Cisco UCS C-Series servers connected to UCS fabric interconnects
2
2
0
7
Cisco UCS
Fabric-A
Cisco UCS
Fabric-B
Cisco
Nexus 2232PP
FEX-A
Cisco
Nexus 2232PP
FEX-B
Fabric
Interconnect
Cisco UCS
C-Series Dual-wire
Managed Server
UCS
B-Series
Chassis
10GbE Ethernet, FCoE, and Management Traffic
10GbE Ethernet and FCoE Traffic
1GbE Management Traffic
FEX to Fabric Uplinks
Cisco UCS C-Series
Single-wire Managed Server
Third-Party Computing Systems
Third-party rack server and blade server systems may also be connected to
the Cisco SBA data center topology with the available 10-Gigabit Ethernet
interfaces on the Cisco Nexus 5500 Series switches, or interfaces on the
Cisco Nexus 2000 Series Fabric Extenders that support Gigabit Ethernet
and 10-Gigabit Ethernet connectivity, depending on the model selected.
To support existing applications and facilitate smooth migration to servers
that support the Cisco Unified Computing System features, you can easily
integrate a previously installed base of running servers into the Cisco SBA
data center architecture.
Server Virtualization and Cisco UCS
Server virtualization technologies allow a single physical server to run mul-
tiple virtual instances of a guest operating system, creating virtual machines.
Running multiple virtual machines on server hardware helps to increase
processor utilization levels, while still allowing each virtual machine to be
viewed as independent from a security, configuration, and troubleshooting
perspective.
Cisco Unified Computing System server platforms provide unique advan-
tages that complement the implementation of server virtualization technolo-
gies. The Cisco UCS servers with Cisco UCS Manager allow the personality
of a server instance to be easily ported to different physical hardware,
similar to porting a virtual machine to a different host. Cisco UCS Manager
provides the capability to directly integrate network interfaces to the hyper-
visor system for dynamic network interface allocation to virtual machines.
This is currently supported with VMware ESX 4.0 Update 1 and above. Cisco
Extended Memory Technology allows individual servers to scale to large
numbers of virtual machines, reducing support and licensing costs.
Cisco UCS servers have been certified with multiple hypervisor systems,
including VMware ESX, Microsoft Hyper-V, and Citrix Xen. Please contact
your Cisco Systems or authorized partner sales representative to verify the
specifics of your implementation requirements with current hardware and
software versions.
9
Deployment Details February 2013 Series 9
Deployment Details
The following sections provide detailed, step-by-step instructions to config-
ure the basic elements of the Cisco SBA Unified Computing System model.
If you are a new user, you can use these common best-practice configura-
tions to quickly configure a new system for basic operations. This is a flex-
ible configuration, so additional information is provided, including pointers
to more detailed documentation that you can use for more advanced system
configurations.
Data Center Core Network Infrastructure
The Cisco SBA foundation data center core network infrastructure for the
Cisco SBA Unified Computing System topology is based on the Cisco
SBAData Center Deployment Guide. The following Ethernet, Fibre
Channel, and FCoE network setup processes prepare the data center core
for connecting to a Cisco UCS B-Series Blade Server system.
Cisco UCS C-Series Rack-Mount Servers may be connected to the Cisco
SBA data center infrastructure, using available interfaces on the Cisco
Nexus 5500UP switches or through the Cisco Nexus 2000 Series Fabric
Extenders. You can configure switching access or trunk port modes accord-
ing to the settings appropriate for the installed operating system. The Cisco
UCS C-Series servers may also be connected to the fabric interconnects
that provide connectivity for the Cisco UCS B-Series servers for a single
control point provided by Cisco UCS Manager.
Configuring the Ethernet Network Infrastructure
1. Configure Nexus 5500 port channels
Process
The Cisco UCS B-Series Blade Servers and Cisco UCS 5100 Series Blade
Server Chassis operate in conjunction with the Cisco UCS 6200 Series
Fabric Interconnects to appear as a group of end-node servers to the
data center Ethernet switching fabric. In the Cisco SBA Unified Computing
System architecture, the fabric interconnects for Ethernet traffic are con-
nected directly to the Cisco Nexus 5500UP Series Ethernet switching fabric
running vPC for the best combination of throughput and resiliency.
Configuration examples in this guide show the use of a port channel with
four physical 10Gigabit Ethernet ports from each Cisco UCS Fabric
Interconnect to the Cisco Nexus 5500 vPC pair. These interfaces are
numbered Ethernet 1/9 through 1/12 on each Cisco Nexus 5500 Series
switch, and ports 17 through 20 on each fabric interconnect in the example
configurations. The port channel from each fabric interconnect spans the
two physical Cisco Nexus 5500 switches for resilient connectivity, as shown
in the figure below. You can use interface numbers specific to your imple-
mentation to achieve the same cabling structure.
Figure 5 - Data center core to fabric interconnect Ethernet cabling
10
Deployment Details February 2013 Series 10
This illustration shows the use of integrated ports on the Cisco
UCS fabric interconnects in the validation network for Ethernet
uplink connections. Expansion module Ethernet ports may also be
used as uplink ports.
Tech Tip
Procedure 1 Congure Nexus 5500 port channels
Step 1: Ensure that the LACP feature is enabled for EtherChannel
operation.
feature lacp
Step 2: Configure the physical interfaces to the port channels on the data
center core Cisco Nexus 5500UP-A switch.
interface Ethernet1/9
description Link to FI-A eth1/17
channel-group 50 mode active
no shutdown
!
interface Ethernet1/10
description Link to FI-A eth1/18
channel-group 50 mode active
no shutdown
!
interface Ethernet1/11
description Link to FI-B eth1/17
channel-group 51 mode active
no shutdown
!
interface Ethernet1/12
description Link to FI-B eth1/18
channel-group 51 mode active
no shutdown
When you assign the channel group to a physical interface, the switchs
operating system creates the logical EtherChannel (port-channel) interface.
Next, you configure the logical port-channel interfaces, and the physical
interfaces tied to the port channel will inherit the settings.
Step 3: Configure the port channels on the data center core Cisco Nexus
5500UP-A switch.
The port channels are created as vPC port channels, because the fabric
interconnects are dual-homed EtherChannels to both data center core
switches.
interface port-channel50
switchport mode trunk
switchport trunk allowed vlan 148-163
spanning-tree port type edge trunk
service-policy type qos input DC-FCOE+1P4Q_INTERFACE-DSCP-
QOS
vpc 50
interface port-channel51
switchport mode trunk
switchport trunk allowed vlan 148-163
spanning-tree port type edge trunk
service-policy type qos input DC-FCOE+1P4Q_INTERFACE-DSCP-
QOS
vpc 51
Setting the spanning-tree port type to edge trunk is appropriate
for the recommended default fabric interconnect configuration
of End Host Mode. If the fabric interconnect is configured in
switched mode, leave the Cisco Nexus 5500 port type set to
normal for standard Spanning Tree Protocol loop prevention.
Tech Tip
The port-channel interfaces do not become active until you complete the
corresponding configuration on the Cisco UCS fabric interconnects, which
is covered in Procedure 2, Define Ethernet uplink ports.
11
Deployment Details February 2013 Series 11
Step 4: Configure the physical interfaces for the port channels, and the port
channels on data center core Cisco Nexus 5500UP-B switch.
interface Ethernet1/9
description Link to FI-A eth1/19
channel-group 50 mode active
no shutdown
!
interface Ethernet1/10
description Link to FI-A eth1/20
channel-group 50 mode active
no shutdown
!
interface Ethernet1/11
description Link to FI-B eth1/19
channel-group 51 mode active
no shutdown
!
interface Ethernet1/12
description Link to FI-B eth1/20
channel-group 51 mode active
no shutdown
!
interface port-channel50
switchport mode trunk
switchport trunk allowed vlan 148-163
spanning-tree port type edge trunk
service-policy type qos input DC-FCOE+1P4Q_INTERFACE-DSCP-
QOS
vpc 50
!
interface port-channel51
switchport mode trunk
switchport trunk allowed vlan 148-163
spanning-tree port type edge trunk
service-policy type qos input DC-FCOE+1P4Q_INTERFACE-DSCP-
QOS
vpc 51
Configuring the Fibre Channel or FCoE Network Infrastructure
1. Configure SAN port channels
Process
If you will access all of your storage strictly over Ethernet by using iSCSI or
NAS protocols, it is not necessary to define or attach Fibre Channel uplinks;
you can skip this process.
Complete the following process to prepare the data center core Cisco
Nexus 5500UP switches to support a Fibre Channel or FCoE SAN connec-
tion to the Cisco UCS Fabric Interconnects. As of Cisco UCS Release 2.1(1a),
the Cisco UCS 6200 Series Fabric Interconnects support either a Fibre
Channel or FCoE SAN connection to the data center core switching fabric.
Configuration instructions and Fibre Channel SAN numbering provided in
this guide are based on the foundation of the Fibre Channel infrastructure in
the Cisco SBAData Center Deployment Guide topology.
Table 1 - Fibre Channel VSAN to FCoE VLAN mapping
Data center core switch VSAN FCoE VLAN
Cisco Nexus 5500UP-A 4 304
Cisco Nexus 5500UP-B 5 305
The following procedure options provide guidance for Fibre Channel (FC)
or FCoE connectivity from the data center core to the Cisco UCS Fabric
Interconnect. Both procedures configure the SAN extension for operation
where the Cisco UCS Fabric Interconnects are operating in the default SAN
FC and Ethernet LAN switching End-Host mode.
12
Deployment Details February 2013 Series 12
Procedure 1 Congure SAN port channels
If you want to use native Fibre Channel to extend the SAN from the data
center core to the Cisco UCS Fabric Interconnect, complete Option 1. If you
want to use FCoE to extend the SAN from the data center core to the Cisco
UCS Fabric Interconnect, complete Option 2.
Option 1. Congure Fibre Channel SAN port channels
Figure 6 - Fibre Channel connection between the data center core and fabric
interconnects
To prepare the data center core Cisco Nexus 5500UP switches for Fibre
Channel connectivity to the fabric interconnect, you must enable NPIV. This
may have already been done during programming according to the Cisco
SBAData Center Deployment Guide.
Step 1: On the data center core Cisco Nexus 5500UP-A switch, enable
NPIV, Fibre Channel port channel trunking, and Fibre Channel or FCoE
switching operation.
feature npiv
feature fport-channel-trunk
feature fcoe
The feature fcoe command is required to enable both Fibre Channel and
FCoE on the Cisco Nexus 5500UP switches.
Step 2: Create a SAN port channel to connect the fabric interconnect to the
data center core Cisco Nexus 5500UP-A switch.
With NPIV enabled, you must assign a virtual SAN (VSAN) to the SAN port
channels that connect to the fabric interconnects. You use the same VSAN
numbering established in the Cisco SBAData Center Deployment Guide.
interface san-port-channel 29
channel mode active
switchport trunk mode on
switchport trunk allowed vsan 1
switchport trunk allowed vsan add 4
Step 3: Add the SAN port channel to an existing VSAN database on the
data center core Cisco Nexus 5500UP-A switch.
vsan database
vsan 4 interface san-port-channel 29
Step 4: On the data center core Cisco Nexus 5500UP-A switch, configure
the SAN port channel on physical interfaces.
The Fibre Channel ports on the Cisco Nexus 5500UP switches are set to
negotiate speed by default.
interface fc1/29
switchport trunk mode on
channel-group 29 force
!
interface fc1/30
switchport trunk mode on
channel-group 29 force
Step 5: Apply the following configuration to the data center core Cisco
Nexus 5500UP-B switch. Note the different VSAN number value used for the
Cisco Nexus 5500UP-B switch.
feature npiv
feature fport-channel-trunk
feature fcoe
!
interface san-port-channel 29
channel mode active
switchport trunk mode on
switchport trunk allowed vsan 1
13
Deployment Details February 2013 Series 13
switchport trunk allowed vsan add 5
!
vsan database
vsan 5 interface san-port-channel 29
!
interface fc1/29
switchport trunk mode on
channel-group 29 force
!
interface fc1/30
switchport trunk mode on
channel-group 29 force
The Fibre Channel SAN port channel interfaces configured in
these steps will not show a status of up until you complete the
upcoming configuration of the fabric interconnects for Fibre
Channel operation in Procedure 2, Define Ethernet uplink ports
in the Configuring Communications Connections using UCS
Manager process.
Tech Tip
Option 2. Congure FCoE SAN port channels
If you want to use FCoE in order to extend the SAN from the data center core
to the Cisco UCS Fabric Interconnect, use this procedure. The EtherChannel
links for FCoE are different than the EtherChannel links for only Ethernet traf-
fic, created in the previous Configuring the Ethernet Network Infrastructure
process.
Figure 7 - FCoE connection between the data center core and fabric interconnects
If you have already configured your Cisco Nexus 5500UP switches for FCoE
operation by following the Configuring the Data Center Core procedure in
the Cisco SBAData Center Deployment Guide you may skip to Step 5.
Step 1: On the data center core Cisco Nexus 5500UP-A switch, enable
NPIV and Fibre Channel or FCoE switching operation, and then ensure that
LACP is enabled.
feature lacp
feature npiv
feature fcoe
The feature fcoe command is required to enable both Fibre Channel and
FCoE on the Cisco Nexus 5500UP switches.
Step 2: If you have not already configured your Cisco Nexus 5500UP
switches for QoS by following the Configuring the Data Center Core proce-
dure in the Cisco SBAData Center Deployment Guide, you must enable
quality of service (QoS) for FCoE operation on the Cisco Nexus 5500UP.
Four lines of QoS statements map the baseline system QoS policies for
FCoE. Without these commands, the virtual FC interface will not function
when activated. If you followed the Cisco SBAData Center Deployment
Guide to deploy your network, you should have already executed a more
comprehensive QoS policy, which includes FCoE traffic classification, so
you can skip this step. If you use the commands below for the baseline FCoE
QoS operation, you will overwrite your existing QoS policy.
14
Deployment Details February 2013 Series 14
system qos
service-policy type qos input fcoe-default-in-policy
service-policy type queuing input fcoe-default-in-policy
service-policy type queuing output fcoe-default-out-policy
service-policy type network-qos fcoe-default-nq-policy
end
All FC and FCoE control and data traffic is automatically classified
into the FCoE system class, which provides a no-drop service. On
the Cisco Nexus 5010 and Cisco Nexus 5020, this class is created
automatically when the system starts up. The class is named
class-fcoe in the CLI.
Tech Tip
Step 3: On the data center core Cisco Nexus 5500UP-A switch, ensure that
an FCoE VLAN has been created. This VLAN that will carry FCoE traffic to
the fabric interconnects.
vlan 304
name FCoE-VLAN_304
exit
Step 4: On the data center core Cisco Nexus 5500UP-A switch, ensure that
VSAN 4 has been created and map VLAN 304 to VSAN 4. VLAN 304 carries
all VSAN 4 traffic over the trunk.
vsan database
vsan 4
vsan 4 name General-Storage
exit
!
vlan 304
fcoe vsan 4
exit
Step 5: Configure a new port channel on the physical interfaces on the
Cisco Nexus 5500UP-A switch, connecting FCoE transport to the fabric
interconnects. Cisco Nexus Operating System automatically creates the
port channel associated with the channel group.
interface ethernet2/1
description FCoE Link to FI-A eth1/33
channel-group 33 mode active
no shutdown
!
interface ethernet2/2
description FCoE Link to FI-A eth1/34
channel-group 33 mode active
no shutdown
Step 6: Configure the port channel created by the previous step to trunk,
and allow the FCoE VLAN (304).
interface port-channel 33
description FCoE EtherChannel Link to FI-A
switchport mode trunk
switchport trunk allowed vlan 304
spanning-tree port type edge trunk
Only use spanning-tree port type edge trunk when the Cisco
UCS Fabric Interconnects are operating in the default Ethernet
LAN switching End-Host mode.
Caution
Step 7: On the data center core Cisco Nexus 5500UP-A switch, create a
virtual Fibre Channel (vfc) interface, bind it to the port channel created in the
previous step, and then configure the interface to trunk VSAN 4.
interface vfc 33
bind interface port-channel33
switchport trunk allowed vsan 4
switchport mode F
no shutdown
15
Deployment Details February 2013 Series 15
Step 8: Apply the following configuration to the data center core Cisco
Nexus 5500UP-B switch, and ensure that QoS is enabled for FCoE operation
as done in Step 2 above. Note the different VSAN number value used for the
Cisco Nexus 5500UP-B switch.
feature lacp
feature npiv
feature fcoe
!
vlan 305
name FCoE-VLAN_305
exit
!
vsan database
vsan 5
vsan 5 name General-Storage
exit
!
vlan 305
fcoe vsan 5
exit
!
interface ethernet2/1
description FCoE Link to FI-B eth1/33
channel-group 33 mode active
no shutdown
!
interface ethernet2/2
description FCoE Link to FI-B eth1/34
channel-group 33 mode active
no shutdown
!
interface port-channel 33
description FCoE EtherChannel Link to FI-B
switchport mode trunk
switchport trunk allowed vlan 305
spanning-tree port type edge trunk
!
interface vfc 33
bind interface port-channel33
switchport trunk allowed vsan 5
switchport mode F
no shutdown
Cisco UCS B-Series Blade Server System
The Cisco UCS B-Series Blade Server system is the heart of the Cisco SBA
Unified Computing System architecture. This section provides information
on initial system setup and basic service profile configuration to prepare
your first running server to boot on one of the blade server modules.
Additional information is provided for setting up service profiles with mul-
tiple interfaces and boot-from-SAN configurations.
Completing the Initial System Setup
1. Complete cabling and ensure connectivity
2. Configure management switch ports
3. Complete initial fabric interconnect setup
Process
Procedure 1 Complete cabling and ensure connectivity
The Cisco UCS fabric interconnects act as the concentration point for all
cabling to and from the UCS 5100 Series Blade Server Chassis.
Step 1: Connect the two fabric interconnects together using the integrated
ports labeled L1/L2. These ports are used for replication of cluster informa-
tion between the two fabric interconnects, not the forwarding of data traffic.
Step 2: Attach the management Ethernet ports from each fabric intercon-
nect to the out-of-band Ethernet management network created in the Cisco
SBAData Center Deployment Guide (or appropriate Ethernet segment)
where they can be accessed for overall administration of the system.
16
Deployment Details February 2013 Series 16
Step 3: Populate each blade chassis with two fabric extenders (I/O mod-
ules) to provide connectivity back to the fabric interconnects.
Step 4: From the Cisco UCS 5100 Blade Server Chassis, connect one I/O
module to the first fabric interconnect. Connect the second I/O module to
the second fabric interconnect. After you have configured the fabric inter-
connects, they will be designated as A and B fabric interconnects.
You can connect the I/O modules to the fabric interconnects by using one,
two, four, or eight cables per module. For system resiliency and throughput,
it is recommended that you use a minimum of two connections per I/O
module.
Ports 1 through 4 on the fabric interconnects are shown as an
example. Additional blade chassis may be connected via their
integrated I/O modules into any of the baseboard ports on the
fabric interconnect. It is recommended that for maximum virtual
NIC scalability, connect the I/O module to the fabric interconnect
with all I/O module ports included in a group of 8 fabric intercon-
nect ports; that is all I/O module ports connect to fabric intercon-
nect ports 1-8, or 9-16, or 17-24, etc.
Tech Tip
Procedure 2 Congure management switch ports
In the Cisco SBAData Center Deployment Guide, an Ethernet out-of-band
management network was created. The management ports for the Cisco
UCS fabric interconnects should connect to this switch and use IP address-
ing from the management VLAN. The ports on the management switch
should be configured for connecting to the fabric interconnect management
ports, as described in this procedure.
Step 1: Configure the ports connected to Cisco UCS.
interface GigabitEthernet1/0/7
switchport access vlan 163
switchport mode access
!
interface GigabitEthernet1/0/8
switchport access vlan 163
switchport mode access
With this configuration, when both the fabric interconnects are up and
configured with the management IP addresses, they are able to ping the
Cisco Nexus 5500 switches.
17
Deployment Details February 2013 Series 17
Procedure 3 Complete initial fabric interconnect setup
You can easily accomplish the initial configuration of the fabric intercon-
nects through the Basic System Configuration dialog that launches when
you power on a new or unconfigured fabric interconnect.
This guide assumes you are configuring a new or unconfigured
unit. If you want to erase the configuration of a Cisco UCS Fabric
Interconnect, access the local management CLI and use the
erase configuration command:
UCS-A# connect local-mgmt
UCS-A(local-mgmt)# erase configuration
Tech Tip
Step 1: Connect a terminal to the console port of the first fabric intercon-
nect to be configured, and then press Enter.
Step 2: In the Basic System Configuration Dialog, enter information as
shown below, and then establish a password for the admin account.
---- Basic System Configuration Dialog ----
This setup utility will guide you through the basic
configuration of the system. Only minimal configuration
including IP connectivity to the Fabric interconnect and its
clustering mode is performed through these steps.
Type Ctrl-C at any time to abort configuration and reboot
system. To back track or make modifications to already entered
values, complete input till end of section and answer no when
prompted to apply configuration.
Enter the configuration method. (console/gui) ? console
Enter the setup mode; setup newly or restore from backup.
(setup/restore) ? setup
You have chosen to setup a new Fabric interconnect. Continue?
(y/n):y
Enforce strong password? (y/n) [y]: y
Enter the password for admin: [xxxxx]
Confirm the password for admin: [xxxxx]
Next, you are prompted to confirm whether the fabric interconnect is part of
a cluster. The Cisco UCS cluster consists of two fabric interconnects, and all
associated configuration is replicated between the two for all devices in the
system.
Step 3: Create a new cluster.
Is this Fabric interconnect part of a cluster(select no for
standalone)? (yes/no) [n]: yes
Each fabric interconnect has a unique physical IP address. A shared cluster
IP address is used to access Cisco UCS Manager after the system initializa-
tion is completed. The fabric interconnects are assigned one of two unique
fabric IDs for both Ethernet and Fibre Channel networking.
Step 4: Choose fabric A for the first fabric interconnect that you are setting
up.
Enter the switch fabric (A/B) []: A
The system name is shared across both fabrics, so -a or -b is auto-
matically appended to the name that you specify in the Basic System
Configuration Dialog when you set up one of the fabric interconnects.
Step 5: Name the Cisco UCS system.
Enter the system name: sba-ucs
Step 6: Apply the following example configuration as you respond to the
prompts.
Physical Switch Mgmt0 IPv4 address : 10.4.63.29
Physical Switch Mgmt0 IPv4 netmask : 255.255.255.0
IPv4 address of the default gateway : 10.4.63.1
Cluster IPv4 address : 10.4.63.31
Configure the DNS Server IPv4 address? (yes/no) [n]: n
Configure the default domain name? (yes/no) [n]: n
Join centralized management environment (UCS Central)? (yes/
no) [n]: n
18
Deployment Details February 2013 Series 18
Step 7: The Basic System Configuration Dialog displays a summary of the
configuration options that you chose. Verify the accuracy of the settings.
Unless the settings require correction, enter yes to apply the configuration.
The system assumes the new identity that you configured.
Following configurations will be applied:
Switch Fabric=A
System Name=sba-ucs
Enforced Strong Password=yes
Physical Switch Mgmt0 IP Address=10.4.63.29
Physical Switch Mgmt0 IP Netmask=255.255.255.0
Default Gateway=10.4.63.1
Cluster Enabled=yes
Cluster IP Address=10.4.63.31
NOTE: Cluster IP will be configured only after both Fabric
Interconnects are initialized
Apply and save the configuration (select no if you want to
re-enter)? (yes/no):yes
Applying configuration. Please wait.
Configuration file Ok
After the system has booted, you can add the second fabric interconnect
to the cluster. Because you have already defined the cluster, you only need
to acknowledge the prompts to add the second fabric interconnect to the
cluster and set a unique IP address.
Step 8: Connect a terminal to the console port of the second fabric inter-
connect to be configured, and then press Enter.
Step 9: In the Basic System Configuration Dialog that follows, enter the
information as shown below, enter the admin password you configured on
the first fabric interconnect to establish a connection to the peer, enter the
management IP address for the second fabric interconnect, and then save
the configuration.
Enter the configuration method. (console/gui) ? console
Installer has detected the presence of a peer Fabric
interconnect. This Fabric interconnect will be added to the
cluster. Continue (y/n) ? y
Enter the admin password of the peer Fabric interconnect:
[xxxxx]
Connecting to peer Fabric interconnect... done
Retrieving config from peer Fabric interconnect...done
Peer Fabric interconnect Mgmt0 IP Address: 10.4.63.29
Peer Fabric interconnect Mgmt0 IP Netmask: 255.255.255.128
Cluster IP address: 10.4.63.31
Physical Switch Mgmt0 IPv4 address : 10.4.63.30
Apply and save the configuration (select no if you want to
re-enter)? (yes/no): yes
Applying configuration. Please wait.
Configuration file Ok
From this point forward, this guide primarily shows the use of
the Cisco UCS Manager GUI for management of the system;
however, you should become familiar with the console in case you
need very low-bandwidth remote access or a separate mode of
access for administrative tasks such as code upgrades or system
troubleshooting.
Tech Tip
19
Deployment Details February 2013 Series 19
Configuring Communications Connections Using UCS Manager
1. Configure fabric-to-I/O-module links
2. Define Ethernet uplink ports
3. Configure SAN uplinks
Process
Cisco UCS Manager is the management service for all of the components in
a Cisco UCS instance. Cisco UCS Manager runs on the fabric interconnects
and keeps configuration data synchronized between the resilient pair. The
primary access method covered here for using Cisco UCS Manager is the
Java-based GUI client, which you launch from a web browser.
Figure 8 - Cisco UCS Manager GUI
The Cisco UCS Manager GUI consists of a navigation pane on the left side
of the screen and a work pane on the right side of the screen. The navigation
pane allows you to browse through containers and objects and to drill down
easily through layers of system management. In addition, the following tabs
appear across the top of the navigation pane:
EquipmentInventory of hardware components and hardware-specific
configuration
ServersService profile configuration and related components such as
policies and pools
LANLAN-specific configuration for Ethernet and IP networking
capabilities
SANSAN-specific configuration for Fibre Channel networking
capabilities
VMConfiguration specific to linking to external server virtualization
software, currently supported for VMware
AdminUser management tasks, fault management, and
troubleshooting
The tabs displayed in the navigation pane are always present as you move
through the system and in conjunction with the tree structure shown within
the pane itself. They are the primary mechanisms for navigating the system.
After you choose a section of the Cisco UCS Manager GUI in the navigation
pane, information and configuration options appear in the work pane on
the right side of the screen. In the work pane, tabs divide information into
categories. The work pane tabs that appear vary according to the context
chosen in the navigation pane.
Any computer that you want to use to run the Cisco UCS Manager client
must meet or exceed the minimum system requirements listed in the
Release Notes for Cisco UCS Software, which can be found on www.cisco.
com.
Procedure 1 Congure fabric-to-I/O-module links
On a newly installed system, one of your first tasks is to define which ports
on the fabric interconnects are attached to the I/O modules in each chassis
(these are referred to as server ports). This allows Cisco UCS Manager to
discover the attached system components and build a view of the entire
system.
Step 1: Using a browser, access the cluster IP address that you assigned
during initial setup in Procedure 3 Complete initial fabric interconnect
setup of the Completing the Initial System Setup process.
This example configuration uses 10.4.63.31 from the setup script.
Authenticate by using the configured username and password, and view the
initial screen.
Step 2: Choose Launch. The Cisco UCS Manager Java application
downloads.
20
Deployment Details February 2013 Series 20
Step 3: In the navigation pane, click the Equipment tab, and then click
the Policies tab in the work pane. On the Policies tab, another set of tabs
appears. By default, the Global Policies tab displays the Chassis Discovery
Policy.
Link Grouping Preference of Port Channel is only supported on
Cisco UCS 2200 Series Fabric Extenders and is recommended
for most applications when using this model.
Tech Tip
Step 4: In the Action list, choose the appropriate number of links for your
configuration, and then click Save Changes at the bottom of the work pane.
The chassis discovery policy may be set at 1, 2, 4, or max, which
is 8 links per fabric; the default value is one. This design sets the
value to two. You can add more links; this only defines the mini-
mum number of I/O module links that must be active to discover a
chassis.
Tech Tip
Step 5: In the navigation pane, click the Equipment tab, and then expand
Fabric Interconnects > Fabric Interconnect A > Fixed Module > Ethernet
Ports.
Objects are displayed representing each of the physical ports on the base
fabric interconnect system.
Step 6: Choose the desired port by clicking the port object, or choose
several sequential ports by clicking additional ports while pressing the Shift
key.
21
Deployment Details February 2013 Series 21
Step 7: Right-click the selected port or group of ports, and then choose
Configure as Server Port.
Step 8: On the Successfully configured message, click OK.
Step 9: In the navigation pane, expand the tree to Fabric Interconnect B,
and then follow Step 5 through Step 8 to configure the resilient links from
Fabric B.
After Cisco UCS Manager has discovered each of the chassis attached to
your system, you can use the Equipment tab in the navigation pane to verify
that each chassis, I/O module, and server is properly reflected. If they do not
show up, or they indicate an error condition, right-click the chassis number,
choose Acknowledge Chassis, and in the pop-up window, click OK. After
the discovery process is done, you can see the result on the Main Topology
View tab in the work pane.
Procedure 2 Dene Ethernet uplink ports
In the Cisco SBA Unified Computing System reference design, Ethernet
uplink ports connect the fabric interconnects to the Cisco Nexus 5500UP
switches via 10-Gigabit Ethernet links. These links carry IP-based client and
server traffic, server-to-server traffic between IP subnets, and Ethernet-
based storage access such as iSCSI or NAS traffic. You may use ports from
either the base fabric interconnects or expansion modules as uplink ports.
Step 1: On the Equipment tab in the navigation pane, locate the ports that
are physically connected to the upstream switches.
22
Deployment Details February 2013 Series 22
Step 2: Choose each port that you selected for your implementation (or
choose sequential ports by clicking additional ports while pressing the Shift
key), right-click, and then choose Configure as Uplink Port.
The Cisco SBA design implemented a port-channel configuration on
the upstream Cisco Nexus 5500UP Series switches as described in the
Procedure 1 Configure Nexus 5500 port channels earlier in this guide. You
must perform similar port-channel configuration for the Ethernet uplink ports
for the fabric interconnects.
Step 3: In the navigation pane, click the LAN tab, expand LAN > LAN Cloud
> Fabric A, and then select the Port Channels container.
Step 4: Click Add (green plus sign).
Step 5: Enter an ID and Name for the new port channel, and then click Next.
For example, enter an ID 50 and a name of Fabric-A-PC-50.
Step 6: In the Ports list, select the Ethernet ports to use as uplinks.
Step 7: Click the right arrows (>>) button. This adds the ports to the Ports
in the port channel list on the right. This design uses ports Slot-1, ports 17
through 20.
Pay close attention to the Slot ID column when you select the ports to be
added to the port channel. Integrated ports are listed with a slot ID of 1. If
you are using an expansion module, scroll down to find ports listed with a
slot ID of 2.
23
Deployment Details February 2013 Series 23
Step 8: Click Finish. This completes the creation of the Ethernet uplink port
channel for Fabric A.
Step 9: Create a port channel for Fabric B by repeating Step 1 through Step
8. In Step 5, use a unique port-channel ID (for example, 51) and name (for
example Fabric-B-PC-51).
Port channel IDs are locally significant to each device; therefore, as shown,
the ID used to identify a port channel to the fabric interconnect does not
have to match the ID used for the channels on the Cisco Nexus 5500 switch
configuration. In some cases, it may be beneficial for operational support to
use consistent numbering for representation of these channels.
Procedure 3 Congure SAN uplinks
If you will access all of your storage strictly over Ethernet by using iSCSI or
NAS protocols, it is not necessary to define or attach Fibre Channel uplinks,
and you can skip the Fibre Channel and FCoE uplink procedures.
If you want to use native Fibre Channel to extend the SAN from the data
center core to the Cisco UCS Fabric Interconnect, Option 1: complete
Option 1 of this procedure. If you want to use FCoE to extend the SAN from
the data center core to the Cisco UCS Fabric Interconnect, complete Option
2 of this procedure.
Option 1. Congure Fibre Channel SAN uplinks
On a Cisco UCS 6200 fabric interconnect, the baseboard ports are universal
ports that can run in the default Ethernet interface mode or can be changed
to operate in Fibre Channel mode. If you will be using Fibre Channel SAN
connectivity from your Cisco UCS 6200 fabric interconnect, the following
steps configure ports for Fibre Channel mode.
Changing the universal port mode operation from Ethernet
to Fibre Channel operation causes the fabric interconnect to
reboot. The remaining fabric interconnect remains active and
able to pass traffic. If this is a new system, this should not pose a
risk; if this is an existing system with active servers dual-homed,
servers continue to communicate via the remaining active fabric
interconnect.
Tech Tip
Step 1: In the navigation pane, click the Equipment tab, expand Fabric
Interconnect, and then select the subordinate fabric interconnect, which in
this case in Fabric Interconnect B.
This deployment uses the subordinate fabric interconnect first to avoid los-
ing GUI access to the fabric. Then it switches fabric interconnect roles and
configures Fabric Interconnect A.
24
Deployment Details February 2013 Series 24
Step 2: In the work pane, click Configure Unified Ports. A popup warning
message appears.
Step 3: Click Yes. This acknowledges the operation.
Step 4: On the Configure Fixed Module Ports screen, beneath the graphic
of the Fixed Module Ports, move the slider from right to left so that it
includes the two right-most ports (ports 47 and 48) for Fibre Channel opera-
tion, and then click Finish. This design uses two ports and the default Fibre
Channel port mode operation of uplink.
The Successfully Configured Ports box appears.
Step 5: Click OK. The Fabric Interconnect-B reboots. While Fabric
Interconnect-B is rebooting the Overall Status shows inoperable until it
has completed the reboot and returns to operational state. Once Fabric
Interconnect-B returns to an Operable status, proceed to the next step.
Step 6: Log in to the Fabric Interconnect Cluster with an SSH CLI session to
the IP address 10.4.63.31, as defined in Step 6 of the Complete initial fabric
interconnect setup procedure.
Step 7: To avoid a long GUI access timeout when configuring Fabric
Interconnect-A Fibre Channel port mode, configure Fabric Interconnect-B to
be the primary.
login as: admin
Cisco UCS 6200 Series Fabric Interconnect
Using keyboard-interactive authentication.
Password:XXXX
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2012, Cisco Systems, Inc. All rights
reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed
under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of
25
Deployment Details February 2013 Series 25
each such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
Step 8: Verify that Fabric Interconnect-A is now the primary.
sba-ucs-A# show cluster state
Cluster Id: 0x99fd3a5684de11e1-0xa340547fee243524
A: UP, PRIMARY
B: UP, SUBORDINATE
HA READY
Step 9: Connect to the local management control process.
sba-ucs-A# connect local-mgmt
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2012, Cisco Systems, Inc. All rights
reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed
under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of
each such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
Step 10: Switch the primary role to fabric interconnect-B.
sba-ucs-A(local-mgmt)# cluster lead b
Cluster Id: 0x99fd3a5684de11e1-0xa340547fee243524
sba-ucs-A(local-mgmt)#
This causes your SSH CLI session to disconnect and your Cisco UCS
Manager GUI console access to lose connection.
Step 11: Click Re-Login on the GUI console access popup message, and
then log in to Cisco UCS Manager again.
Step 12: In the navigation pane, click the Equipment tab, and then expand
Fabric Interconnect. Note that Fabric Interconnect B is now the primary.
Step 13: Select the subordinate fabric interconnect, which in this case in
Fabric Interconnect A.
Step 14: Follow Step 2 and Step 4 above to configure Fibre Channel ports
on Fabric Interconnect A.
Next, after you have completed the tasks and the Fabric Interconnect A
has returned to operable state, you verify that you now have Fibre Channel
uplink ports available to configure.
Step 15: On the SAN tab, expand SAN Cloud > Fabric A > Uplink FC
Interfaces, and then expand Fabric B > Uplink FC Interfaces. You should
see the Fibre Channel uplinks listed in the display.
Step 16: Connect the Fibre Channel configured ports on the Cisco UCS
6200 Fabric Interconnect to the data center core Cisco Nexus 5500 switch
SAN.
26
Deployment Details February 2013 Series 26
Step 17: Disable unused ports by right-clicking the port name in the naviga-
tion pane, and then choosing Disable. When you disable unused ports, you
clear any system alerts tied to the unused ports in both fabric interconnects
A and B.
Next, you must create a VSAN and assign it to the Fibre Channel port to
activate the port and transmit traffic. This VSAN should match the VSAN
configured on the corresponding SAN fabric, as referred to in Table 1 Fibre
Channel VSAN to FCoE VLAN mapping.
Step 18: In the navigation pane, click the SAN tab, and then expand SAN >
SAN Cloud > VSANs.
Step 19: Right-click the SAN Cloud container, and then choose Create
VSAN.
Step 20: Enter a Name for the VSAN, leave the default value selected for FC
Zoning as Disabled, and then select Both Fabrics Configured Differently.
Step 21: Enter the VSAN IDs corresponding to the SAN-A and SAN-B
VSANs configured in your SAN fabrics. In the Cisco SBAData Center
Deployment Guide, VSAN 4 is assigned to SAN-A, and VSAN 5 is assigned
to SAN-B.
Step 22: For each fabric, enter the VLAN that the Fibre Channel traffic
should use from the chassis to the fabric interconnects. VSAN ID 4 on
Fabric A corresponds to FCoE VLAN 304 on the fabric interconnect, and
VSAN ID 5 on Fabric B corresponds to FCoE VLAN 305 on the fabric
interconnect.
Step 23: When you have configured the VSAN IDs in this section, click OK.
A window shows the successful creation of the VSAN.
Now that you have created the VSAN, you can create a SAN port-channel to
connect to the data center core Cisco Nexus 5500UP switches.
27
Deployment Details February 2013 Series 27
Step 24: In the navigation pane on the SAN tab, expand SAN Cloud, expand
Fabric A, right-click FC Port Channels, and then choose Create Port
Channel.
Step 25: Enter an ID and name for the port channel, and then click Next.
Step 26: In the Ports list, select the ports, and then click the right arrows
(>>) button to move them to the Ports in the port channel list. Click Finish
when you have added the physical uplink ports to the port channel.
Step 27: On the Successfully created message, click OK.
Step 28: Expand FC Port Channels. You can see the newly created port
channel.
Step 29: In the main window, double-click the new port channel. The next
step is to configure the VSAN assignment.
Step 30: In the work pane, on the General tab, inside the Properties box, in
the VSAN list, choose the VSAN for SAN Fabric A on Fabric Interconnect A
operation, and then click Save Changes.
If the port channel fails to come up, you may have to reset the cor-
responding ports on the data center core Cisco Nexus 5500UP
switches. To do so via CLI, enter interface configuration mode for
the SAN port channel 29, enter the shutdown command, and then
enter the no shutdown command.
Tech Tip
Step 31: Repeat Step 24 through Step 30 for the VSAN for SAN Fabric B on
Fabric Interconnect B.
28
Deployment Details February 2013 Series 28
Option 2. Congure FCoE SAN uplinks
If you want to use FCoE to extend the SAN from the data center core to the
Cisco UCS Fabric Interconnect, as configured in Option 2: Configure FCoE
SAN port channels earlier in this guide, use this procedure.
First you must create a VSAN and assign it to the FCoE port channel. This
VSAN should match the VSAN configured on the corresponding SAN fabric
as referred to in Table 1 Fibre Channel VSAN to FCoE VLAN mapping.
Step 1: In the navigation pane, click the SAN tab, and then expand SAN >
SAN Cloud > VSANs.
Step 2: Right-click the SAN Cloud container, and then choose Create
VSAN.
Step 3: Enter a Name for the VSAN, leave the default value selected for FC
Zoning as Disabled, and then select Both Fabrics Configured Differently.
Step 4: Enter the VSAN IDs corresponding to the SAN-A and SAN-B VSANs
configured in your SAN fabrics. In the Cisco SBAData Center Deployment
Guide, VSAN 4 is assigned to SAN-A, and VSAN 5 is assigned to SAN-B.
Step 5: For each fabric, enter the VLAN that the Fibre Channel traffic should
use from the chassis to the fabric interconnects. VSAN ID 4 on Fabric A
corresponds to FCoE VLAN 304 on the fabric interconnect, and VSAN ID 5
on Fabric B corresponds to FCoE VLAN 305 on the fabric interconnect.
Step 6: When you have configured the VSAN IDs in this section, click OK. A
window shows the successful creation of the VSAN.
Now that you have created the VSAN, you can create an FCoE SAN port-
channel to connect to the data center core Cisco Nexus 5500UP switches.
29
Deployment Details February 2013 Series 29
Step 7: In the navigation pane, on the Equipment tab, locate the ports on
Fabric A that are physically connected to the data center core Cisco Nexus
5500 switches for FCoE SAN traffic. These ports were configured on the
data center core in Option 2: Configure FCoE SAN port channels.
Step 8: Choose each port that you selected for your implementation (or
choose sequential ports by clicking additional ports while pressing the Shift
key), right-click, and then choose Configure as FCoE Uplink Port.
Step 9: In the confirmation message, click Yes to configure the port as
FCoE Uplink Port.
Step 10: In the navigation pane, on the SAN tab, expand SAN Cloud,
expand Fabric A, right-click FCoE Port Channels, and then choose Create
FCoE Port Channel.
Step 11: Enter an ID and name for the port channel, and then click Next.
Step 12: In the Ports list, select the ports, and then click the right arrows
(>>) button to move them to the Ports in the port channel list. Click Finish
when you have added the physical uplink ports to the port channel.
Step 13: On the Successfully created message, click OK.
Step 14: In the main window, double-click the new port channel. The next
step is to configure the VSAN assignment.
30
Deployment Details February 2013 Series 30
Step 15: In the work pane, on the General tab, inside the Properties box, in
the VSAN list, choose the VSAN for the SAN Fabric A on Fabric Interconnect
A operation, and then click Save Changes.
Step 16: Repeat Step 7 through Step 15 for Fabric Interconnect B FCoE
uplink ports and SAN port-channel creation.
Configuring Common System Address Pools and VLANs
1. Add a management IP address pool
2. Create UUID pool
3. Create WWNN pool
4. Create WWPN pools
5. Create MAC pool
6. Create VLANs
Process
When configuring the Cisco UCS Management address pools for a fabric
interconnect pair, it is advised to customize some addressing to your
environment so that you can more easily configure and identify addresses
related to a fabric interconnect or UCS Manager domain. However it is rec-
ommended to preserve the IEEE assigned organizationally unique identifier
(OUI) addressing when possible in order to avoid conflicts and operational
issues. This design will use a hex pair of FF as the UCS Manager domain
identifier for this fabric interconnect pair in the following fields:
Universally unique identifier (UUID) suffix pool
Fibre Channel World Wide Node Name (WWNN) and World Wide Port
Name (WWPN) pools
MAC address pool
In addition to the Cisco UCS Manager domain identifier, some pools
will contain a UCS Fabric Interconnect identifier of 0A or 0B for Fabric
Interconnect A and B respectively.
Table 2 - Cisco UCS Manager Fibre Channel WW Names pools
WW Name field Address Comments
WW Node Name 20: FF: 00:25:B5: 00: 00: 01 Preserve NAA=2 format
prefix (20:)
WW Port Name
FI-A
20: FF: 00:25:B5: 0A: 00: 01 Fabric Interconnect-A
WWPN range
WW Port Name
FI-B
20: FF: 00:25:B5: 0B: 00: 01 Fabric Interconnect-B
WWPN range
The VLAN and IP address assignment in this process aligns to the address-
ing used in the Cisco SBAData Center Deployment Guide as well as
VLAN 160, which is used in the Cisco SBAData Center Virtualization
with Cisco UCS, Nexus 1000V, and VMware Deployment Guide. Actual
VLANs and IP address assignment may vary based on your deployment
requirements.
Table 3 - Cisco SBA data center VLANs and IP address ranges
VLAN VLAN name IP address Comments
148 Servers_1 10.4.48.0/24 General network server use
149 Servers_2 10.4.49.0/24 General server use
150 Servers_3 10.4. 50.0/24 General server use
154 FW_Inside_1 10.4. 54.0/24 Firewall-protected servers
155 FW_Inside_2 10.4. 55.0/24 Firewall and IPS protected
servers
160 1kv-Control 10.4.60.0/24 Cisco Nexus 1000V Control
161 vMotion 10.4.61.0/24 Reserved for VMware vMotion
traffic future use
162 iSCSI 10.4.62.0/24 Reserved for iSCSI storage
traffic
163 DC-Management 10.4.63.0/24 Out-of-band data center
management VLAN
31
Deployment Details February 2013 Series 31
Procedure 1 Add a management IP address pool
The Cisco UCS Manager GUI provides a launching point to direct keyboard-
video-mouse (KVM) access to control each of the blade servers within the
system. To facilitate this remote management access, you must allocate
a pool of IP addresses to the blade servers within the system. These
addresses are used by the Cisco UCS KVM Console application to com-
municate with the individual blade servers. You must allocate this pool
of addresses from the same IP subnet as the addresses assigned to the
management interfaces of the fabric interconnects, because a common
default gateway is used for their communication.
This procedure assigns an IP address pool from the DC-Management IP
address range listed in Table 3.
Step 1: In the navigation pane, click the LAN tab, expand LAN > Pools >
root > IP Pools, and then choose IP Pool ext-mgmt.
Step 2: In the work pane, on the General tab, click Create Block of IP
Addresses.
Step 3: Allocate a contiguous block of IP addresses by specifying the start-
ing address in the From box, the Size of the block, the Subnet Mask, and
the Default Gateway, and then click OK. The size of the block needs to be
large enough to assign one address to each server connected to the fabric.
In this example, you can use 32 addresses for the size of the block.
Step 4: After you complete the initial setup, ensure that the system firmware
is updated to the most current version or to the version recommended for
your installation.
Detailed information on upgrading firmware is available at:
http: //www.cisco.com/en/US/products/ps10281/prod_
installation_guides_list.html
Reader Tip
32
Deployment Details February 2013 Series 32
Procedure 2 Create UUID pool
Step 1: In the navigation pane, click the Servers tab, expand Servers >
Pools > root > UUID Suffix Pools, and then choose Pool default.
A universally unique identifier (UUID) suffix pool is a collection of
SMBIOS UUIDs that are available to be assigned to servers. The
first number of digits that constitute the prefix of the UUID are
fixed. The remaining digits, the UUID suffix, are variable. A UUID
suffix pool avoids conflicts by ensuring that these variable values
are unique for each server associated with a service profile that
uses that particular pool. It is recommended that you do not alter
the UUID prefix, and only customize the UUID suffix for your
identification requirements.
Tech Tip
Step 2: On the General tab, under the Actions pane, select Create a Block
of UUID Suffixes.
Step 3: In the Create a Block of UUID Suffixes window, in the From box,
enter a unique, randomized base value as a starting point. This guide
assigns the Cisco UCS Manager domain an identifier of FF in the suffix
field.
You can find UUID generation tools that are compliant with RFC
4122 on the Internet. For an example, see:
http: //www.famkruithof.net/uuid/uuidgen
Reader Tip
Step 4: In the Size box, enter a number larger than the number of servers
or service profiles that you require to use the same pool. If future expansion
is required, you can add multiple UUID suffix blocks to the same pool. For
a base system startup, a simple, small pool is sufficient. This example uses
512.
Step 5: Click OK.
33
Deployment Details February 2013 Series 33
Procedure 3 Create WWNN pool
A World Wide Names (WWN) pool is a collection of WWNs for use by the
Fibre Channel vHBAs in a Cisco UCS domain. You must provision a pool of
World Wide Node Names (WWNNs) in the system, and you must assign the
WWNNs in the pool to servers that need to access the Fibre Channel SAN.
You assign one WWNN from the pool to each server. Each WWNN corre-
sponds to the identity of a Fibre Channel end-node. World Wide Port Names
(WWPNs) are assigned to the vHBA
Step 1: In the Cisco UCM Manager navigation pane, click the SAN tab, and
then expand SAN > Pools > Root > WWNN Pools.
Step 2: Right-click WWNN Pools, and then select Create WWNN Pool.
Step 3: Enter a Name and Description for the new pool, and then click
Next.
Next, create a block of WWNN addresses by defining a starting point and
the quantity of addresses in the block.
Step 4: In the Add WWN Blocks work pane click Add.
Step 5: In the Create WWNN Block window, in the From box, enter a
WWN prefix. The system provides a prefix to help ensure uniqueness of
the WWNN values on the SAN. Assign the last three segments of the base
WWNN value in colon-delimited notation, as needed for your system. This
guide assigns the Cisco UCS Manager domain an identifier of FF in the
second hex pair of the WWN block, thereby preserving the required 20
hex pair in the first block, and the OUI identifier of 00:25:B5 in hex pairs 3
through 5.
For more information on WWN, WWNN, and WWPN, see the
Cisco UCS Manager GUI Configuration Guide:
http: //www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/
config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_
chapter_011000.html
Reader Tip
Step 6: In the Size box, specify the number of node names required, and
then click OK.
Step 7: Click Finish. This completes the creation of the new WWNN pool. If
you include a pool of WWNNs in a service profile, the associated server is
assigned a WWNN from that pool.
34
Deployment Details February 2013 Series 34
Procedure 4 Create WWPN pools
Both Fibre Channel port and node addressing assignments are required in
order for Cisco UCS to provide access through the SAN fabric to the disk
array. Using WWPNs and WWNNs that are independent from the physical
hardware allows you to assign the service profile to any server in the Cisco
UCS system. This allows the server to assume the correct server identity
and SAN access privileges. Similar to the WWNN pool that you created in
Procedure 3, you must provision a pool of WWPNs for the system to assign
port addresses consistently when you add new service profiles to the
system. A given device can have only one WWNN but many WWPNs. We
will create two pools for WWPNs, one for Fabric A and other for Fabric B.
Step 1: In the Cisco UCM Manager navigation pane, click the SAN tab, and
then expand SAN > Pools > Root > WWPN Pools.
Step 2: Right-click WWPN Pools, and then select Create WWPN Pool.
Step 3: Enter a Name and Description for the pool, and then click Next.
Step 4: On the WWN Blocks page, click Add. This creates a new WWPN
block.
Step 5: In the Create WWN Block window, in the From box, assign a unique
WWPN value that identifies that the WWPN pool belongs to Fabric A,
according to Table 2.
Step 6: In the Size box, specify the number of port names required in the
pool, and then click OK.
Step 7: Click Finish.
Step 8: Repeat the above steps to create WWPN pool for Fabric B, follow-
ing the addressing assigned in Table 2.
Procedure 5 Create MAC pool
A MAC pool is collection of MAC addresses that are unique in their Layer 2
environment and are assigned to the vNICs on a server. This pool of MAC
addresses is used by vNIC interfaces in service profiles. Using a pool
of MAC addresses instead of hardware-based MAC addresses allows a
service profile to retain the same MAC address for its network interfaces,
even when it is assigned to a new blade server in the system.
Similar to the Cisco UCS domain addressing used in the previous proce-
dures in this process, you assign a domain identifier of FF for this UCS
domain. It is recommended that you retain the OUI value in the MAC address
field (00:25:B5) and assign any unique identifiers to the right of this portion
of the address field.
Step 1: In the Cisco UCM Manager navigation pane, click the LAN tab, and
then expand LAN > Pools > Root > MAC Pools.
35
Deployment Details February 2013 Series 35
Step 2: Under MAC Pools section, select MAC POOL default.
Step 3: Right-click MAC POOL default, and then select Create a Block of
MAC Addresses. The Create a Block of MAC Addresses window allows you
to define the starting address and the number of addresses to include in the
block. Next, you create a block of addresses large enough to allocate one
address to each vNIC that will exist in the system.
Step 4: In the First MAC Address box, add the starting address for
the MAC address block, and then in the Size box, enter the number of
addresses to allocate.
Step 5: Click OK, and then click OK to acknowledge creation of the pool.
Procedure 6 Create VLANs
The VLANs created for the Cisco SBA data center are replicated here for
your reference. Actual VLANs and IP address assignment may vary based
on your deployment requirements.
Table 4 - Cisco SBA data center VLANs and IP address ranges
VLAN VLAN name IP address Comments
148 Servers_1 10.4.48.0/24 General network server use
149 Servers_2 10.4.49.0/24 General server use
150 Servers_3 10.4. 50.0/24 General server use
154 FW_Inside_1 10.4. 54.0/24 Firewall-protected servers
155 FW_Inside_2 10.4. 55.0/24 Firewall and IPS protected
servers
160 1kv-Control 10.4.60.0/24 Cisco Nexus 1000V Control
161 vMotion 10.4.61.0/24 Reserved for VMware vMotion
traffic future use
162 iSCSI 10.4.62.0/24 Reserved for iSCSI storage
traffic
163 DC-Management 10.4.63.0/24 Out-of-band data center
management VLAN
Step 1: In the Cisco UCM Manager navigation pane, click the LAN tab, and
then select LAN Cloud.
Step 2: Right-click LAN Cloud, and then select Create VLANs.
36
Deployment Details February 2013 Series 36
Step 3: Enter a VLAN Name, select Common/Global, options for scope of
VLAN and enter the VLAN ID, and then click OK.
Step 4: In the Create VLANs dialog box that pops up, you will note that
VLAN was successfully created. Click OK.
Step 5: Create the remaining VLANs by following Step 1 through Step 4.
Most single operating systems that have been installed directly
on a server use a single VLAN for server-to-network operation. In
hypervisor installations where multiple applications or servers will
be hosted, trunking multiple VLANs is more likely.
Tech Tip
Configuring Virtual Adapter Templates
1. Create Network Control Policy
2. Create vNIC templates
3. Create vHBA templates
Process
This process will configure a basic Network Control Policy, an Ethernet vNIC
template, and a Fibre Channel SAN vHBA template.
Procedure 1 Create Network Control Policy
Cisco Discovery Protocol (CDP) should be enabled in order to help trouble-
shoot any connectivity problems on both physical and virtual adapters.
Create a policy to enable CDP.
Step 1: In the navigation pane, click the LAN tab, and then expand LAN >
Policies > root > Network Control Policies.
Step 2: Right-click Network Control Policies, and then choose Create
Network Control Policy.
37
Deployment Details February 2013 Series 37
Step 3: In the Create Network Control Policy dialog box, enter a name for
the policy, select Enabled for CDP, and then click OK.
Procedure 2 Create vNIC templates
A vNIC template defines how a vNIC on a server connects to the LAN. You
create two vNIC templates, one associated to Fabric A and other associated
to Fabric B.
Step 1: In the navigation pane, click the LAN tab, and then expand LAN >
Policies > root > vNIC Templates.
Step 2: Right-click vNIC Templates, and then choose Create vNIC
Template.
Step 3: Enter a name for vNIC template, and then for Fabric ID, select Fabric
A.
Step 4: Under Target, ensure only Adapter is selected, select Updating
Template as the Template Type, and then select all VLANs that needs to be
assigned to the vNIC.
Step 5: In the Network Control Policy list, select the policy created in
Procedure 1. This template will be added to the Service Profiles in the later
sections. By selecting Updating Template as the Template type, vNICs
created from this template are updated if the template changes.
38
Deployment Details February 2013 Series 38
Fabric failover is appropriate for configurations with a single
host operating system installed directly on the blade server. For
a virtualized environment, it is recommended instead that you dis-
able fabric failover, present multiple vNICs to the hypervisor, and
allow the hypervisor system to manage the failover of traffic in the
event of a loss of connection to one of the fabric interconnects.
See the Cisco SBAData Center Virtualization with UCS, Nexus
1000V and VMware Deployment Guide for more information on
presenting multiple vNICs to a hypervisor explanation.
Tech Tip
Step 6: Click OK.
Step 7: Repeat Step 1 through Step 6 in order to create a vNIC template for
vNICs that connect to Fabric B.
Procedure 3 Create vHBA templates
The vHBA template defines how a vHBA on a server connects to the Fibre
Channel SAN.
Step 1: In the navigation pane, click the SAN tab, and then expand SAN >
Policies > root > vHBA Templates.
Step 2: Right-click vHBA Templates, and then choose Create vHBA
Template.
Step 3: Enter the following information and then click OK:
NamevHBA-Fabric-A
Fabric IDA
Select VSANGeneral Storage, which was created in Procedure 3
Configure SAN uplinks.
Template TypeInitial Template
WWPN PoolSBA-WWPN-FabA, which was created in Procedure 4
Create WWPN pools.
39
Deployment Details February 2013 Series 39
Step 4: Repeat Step 2 through Step 3 in order to create a vHBA template for
vHBAs that connect to Fabric B, using the following information:
NamevHBA-Fabric-B
Fabric IDB
Select VSANGeneral Storage which was created in Procedure 3
Configure SAN uplinks.
Template TypeInitial Template
WWPN PoolSBA-WWPN-FabB which was created in Procedure 4
Create WWPN pools.
Configuring Server Boot Policy
1. Create local disk configuration policy
2. Create a local boot policy
3. Create a SAN boot policy
Process
In this process, you will create:
A Local Disk policy for servers that have physically local hard drives.
A No Local Disk policy for servers that have no physically local hard
drives and will utilize SAN boot.
A Local Boot policy for servers that will boot from removable media such
as Compact Disks (CD) or a local hard drive.
A SAN Boot policy for servers that will boot from removable media such
as CDs or a SAN boot target LUN.
Building multiple policies will provide flexibility for different hardware
environments in your Cisco UCS domain.
Procedure 1 Create local disk conguration policy
The local disk configuration policy allows the service profile to define how
the block storage is structured on the local disks installed in each Cisco
UCS blade server. A common configuration is to have two locally installed
disks in each blade, set up for mirrored storage.
Step 1: In the navigation pane, click the Servers tab, and then expand
Servers > Policies > root > Local Disk Configuration Policies.
Step 2: Right-click Local Disk Configuration Policies, and then select
Create Local Disk Configuration Policy.
Step 3: Enter a Name and Description for the policy, and then in the Mode
list, choose Raid 1 Mirrored.
Step 4: Ensure Protect Configuration is selected. If selected, the server
retains the configuration in the local disk configuration policy even if the
server is disassociated from the service profile.
Step 5: Click OK, and then acknowledge the creation.
To prepare for servers that boot from SAN, you create a policy that will not
configure and install any Local Disk for your blade server.
Step 6: In the navigation pane, click the Servers tab, and then expand
Servers > Policies > root > Local Disk Configuration Policies.
40
Deployment Details February 2013 Series 40
Step 7: Right-click Local Disk Configuration Policies, and then select
Create Local Disk Configuration Policy.
Step 8: Enter a Name and Description for the policy, and then in the Mode
list, choose No Local Storage.
Step 9: Click OK, and acknowledge the creation.
Procedure 2 Create a local boot policy
The server boot order policy allows you to control the priority of different
boot devices, to which the server will have access. In this procedure, you will
first configure a basic boot policy that boots first from removable mediain
this case, an attached CD or DVD driveand then from the internal disk.
Step 1: In the navigation pane, click the Servers tab, and then expand
Servers > Policies > root > Boot Policies.
Step 2: Right-click Boot Policies, and select Create Boot Policy.
Step 3: In the Create Boot Policy window, enter the Name and Description
for the boot policy.
Step 4: Click the down arrows on the Local Devices container, click Add
CD-ROM first, and then click Add Local Disk.
The order of the devices in the list is displayed as a number in the Order
column of the table.
Step 5: Verify the choices, and then click OK.
Procedure 3 Create a SAN boot policy
The following steps will guide you to create boot-from-SAN policy. The
policy will include a boot order that starts with any attached removable
media, such as CD or DVD, and then will specify target WWPN of the storage
system that houses the server boot LUN.
In addition to the configuration on the Cisco UCS for SAN boot, you will need
to configure a LUN on your storage array, and Fibre Channel zoning on the
data center core for the server to storage array connections according to
the Cisco SBAData Center Deployment Guide.
On storage arrays with redundant storage controllers, you may have up to
four paths to the target LUN (LUN 0) for boot, two paths over SAN-A and two
paths over SAN-B. If your storage array does not have redundant storage
controllers, you only have two paths, one path over SAN-A and one over
SAN-B. Only one of the paths will be configured as primary.
Table 5 - Example vHBA SAN boot target connections
vHBA Target type Boot target WWPN Target array controller
fc0 Primary 50: 06: 01:61:3C:E0:60:E2 A
fc0 Secondary 50: 06: 01:69:3C:E0:60:E2 B
fc1 Secondary 50: 06: 01:60:3C:E0:60:E2 A
fc1 Secondary 50: 06: 01:68:3C:E0:60:E2 B
41
Deployment Details February 2013 Series 41
Step 1: In the navigation pane, click the Servers tab, and then expand
Servers > Policies > root > Boot Policies.
Step 2: Right-click Boot Policies, and then select Create Boot Policy.
Step 3: In the Create Boot Policy window, enter the Name and Description
for the boot policy.
Step 4: Click the down arrows on the Local Devices container, and then
click Add CD-ROM first.
Step 5: In the left pane, click vHBAs, and then click Add SAN Boot.
When you create a boot policy that targets the WWPN of the
storage system, the boot policy may be reused across multiple
service profiles. Many storage systems can present a different
LUN as a boot LUN or LUN 0 to different initiators, based on the
initiator WWPN address. Referencing a common boot policy pro-
motes configuration consistency across similar service profiles.
Tech Tip
Step 6: In the Add SAN Boot window, in the vHBA box, enter a name
(Example: fc0) that you will be defining for the vHBA of your system. For
Type, select Primary, and then click OK.
Because the boot policy references the vHBA by name, you must
name interfaces consistently across service profiles that need to
share a common boot policy definition.
Make note of the vHBA names you use, as you will use the same
name for vHBA in your service profiles in a later procedure.
Tech Tip
Step 7: In the Create Boot Policy window, click Add SAN Boot Target.
Step 8: In the Add SAN Boot Target dialog box, in the Boot Target LUN box,
enter the specific LUN number for the system to boot. Typically, the boot
LUN is presented by the storage system as LUN 0 to the requesting initiator.
42
Deployment Details February 2013 Series 42
Step 9: In the Boot Target WWPN box, enter the proper SAN target WWPN
of FC adapter interface of target array controller A using SAN-A, and then
click OK.
Step 10: Click Add SAN Boot Target.
Step 11: In the Add San Boot Target dialog box, keep the Boot Target LUN
as 0.
Step 12: In the Boot Target WWPN box, enter the proper SAN target WWPN
of FC adapter interface of target array controller B using SAN-A, and then
click OK.

Now you will add SAN Boot targets for your second vHBA.
Step 13: In the left pane, click vHBAs, and then click Add SAN Boot.
Step 14: In the Add SAN Boot window, in the vHBA box, enter a name
(Example: fc1) that you will be defining for the second vHBA of your system,
and then click OK. The type will be set to Secondary.
Step 15: Click Add SAN Boot Target.
Step 16: In the Add SAN Boot Target dialog box, in the Boot Target WWPN
box, enter the proper SAN target WWPN of FC adapter interface of target
array controller A using SAN-B, and then click OK.
Step 17: Click Add SAN Boot Target.
Step 18: In the Add SAN Boot Target dialog box, deep the value for Boot
Target LUN as 0.
43
Deployment Details February 2013 Series 43
Step 19: In the Boot Target WWPN box, enter the proper SAN target
WWPN of FC adapter interface of target array controller B using SAN-B,
click OK, and then click OK to create the policy.
You can configure redundant access to the boot LUN for some
operating systems during installation; on others it must be added
after you have completed the initial installation.
For example: Windows requires a single HBA during installation
until multipath drivers are installed. For more information, see:
http: //www.microsoft.com/downloads/details.
aspx?FamilyID=f4095fae-553d-4700-aafa-
1cce38b5618f&displaylang=en
Other operating systems have different requirements. Please
refer to your specific operating system documentation for han-
dling redundant SAN connections.
Tech Tip
The following summary screen shows multiple vHBAs configured with
multiple paths to the SAN target boot LUN 0.
44
Deployment Details February 2013 Series 44
Creating an Initial Boot Service Profile for Local Boot
1. Create Service Profile for Local boot
2. Assign service profile and policies
Process
One of the core concepts of Cisco UCS Manager is the service profile. A
service profile defines all characteristics that are normally presented by a
physical server to a host operating system or a hypervisor, including the
presence of network interfaces and their addresses, host adapters and their
addresses, boot order, disk configuration, and firmware versions. The profile
can be assigned to one or more physical blade servers within the chassis. In
this way, what is traditionally thought of as the personality of a given server
or host is tied to the service profile rather than to the physical server blade
where the profile is running. This is particularly true if network-based or
SAN-based boot is configured for the profile. If local-boot is configured for
the profile, the boot images installed on the local hard drives of the physical
blade do tie the identity of the service profile to a given physical server
blade.
There are multiple supporting objects within the Cisco UCS Manager GUI
to streamline the creation of a service profile. These objects contain items
such as pools of MAC addresses for Ethernet, World Wide Port Names
(WWPNs) for Fibre Channel, disk configurations, VLANs, VSANs, etc. These
objects are stored by the system so that they may be referenced by multiple
service profiles, so you do not need to redefine them as you create each
new profile.
This process provides an example of how to create a basic service profile
for initial installation and boot of a host operating system or a hypervisor.
Throughout this process, you create reusable system objects to facilitate
faster creation of additional profiles that share similar characteristics. For
simplicity, in this process you configure a basic boot policy using local
mirrored disks. This initial profile creates the base system setup upon which
you can build additional, more advanced profiles. Later sections in this guide
show options for network-based or SAN-based boot.
Procedure 1 Create Service Prole for Local boot
Step 1: On the Servers tab in the navigation pane, expand the containers
underneath Service Profiles, and then select the Root container.
Step 2: On the General tab in the work pane, click Create Service Profile
(expert), and then on the Identify Service Profile page, enter a name for the
service profile in the Name box.
Step 3: In the UUID section, in the UUID Assignment list, choose the UUID
suffix pool you created in Procedure 2 Create UUID pool, and then click
Next.
Step 4: In the Networking section, Leave the Dynamic vNIC Connection
Policy list set to its default, and next to How would you like to configure
LAN connectivity?, select Expert.
45
Deployment Details February 2013 Series 45
Step 5: Click Add to add vNICs to the server.
Step 6: In the Create vNIC window, in the Name box, enter a name for the
vNIC. For the example configuration, this guide uses eth0 as the interface
name; representing Ethernet 0.
Step 7: Select Use vNIC Template. In the vNIC Template list, select the
vNIC Template created for Fabric A in Procedure 2 Create vNIC templates.
Step 8: In the Adapter policy list, select a policy from a list of pre-defined
policies set according to the OS vendors optimal performance suggestions.
This example uses the Ethernet Adapter policy for VMware.
Step 9: Click OK. This adds the vNIC.
Step 10: Repeat Step 5 through Step 9 in order to add a second vNIC, eth
1, using the vNIC template for Fabric B, created in Procedure 2 Create vNIC
templates.
Step 11: On the Networking page, click Next.
46
Deployment Details February 2013 Series 46
Step 12: On the Storage page, in the Local Storage list, select the local
disk configuration policy created in Procedure 1 Create local disk configu-
ration policy for local disks installed in the Cisco UCS blade server.
Step 13: Next to How would you like to configure SAN connectivity?,
select Expert.
Step 14: In the WWNN Assignment list, select the WWNN pool created in
Procedure 3 Create WWNN pool.
Step 15: Click Add to add vHBA to the server.
Step 16: In the Create vHBA window, in the Name box, enter a name for the
vHBA. For the example configuration, this guide uses fc0 as the interface
name; representing vHBA 0.
Step 17: Select Use vHBA Template. In the vHBA Template list, select
the vHBA Template created for Fabric A in Procedure 3 Create vHBA
templates.
Step 18: In the Adapter policy list, select a policy from a list of pre-defined
policies set according to the OS vendors optimal performance suggestions.
This example uses Fibre Channel Adapter policy for VMware.
Step 19: Repeat Step 15 through Step 18 in order to add a second vHBA,
fc1. Select the vHBA Template created for Fabric B in Procedure 3 Create
vHBA templates.
Step 20: On the Storage page, click Next.
47
Deployment Details February 2013 Series 47
Step 21: On the Zoning page, do not make any changes. Click Next.
Step 22: On the vNIC/vHBA Place page, leave the defaults, and then click
Next. The system places the virtual interfaces on the physical interfaces that
exist on the blade servers with which this profile will be associated.
Step 23: On the Server Boot Order page, in the Boot policy list, select the
boot policy created in Procedure 2 Create a local boot policy, which is
configured to first boot from CD/DVD drive and then from the internal disk.
Click Next.
Step 24: On the Maintenance Policy page, leave all default settings, and
then click Next.
Step 25: On the Server Assignment page, in the Server Assignment list,
select Assign Later, and then click Next.
Step 26: On the Operational Policies page, leave all default settings, and
then click Finish.
Step 27: On the successful completion message, click OK. This exits the
Service Profile Creation Wizard.
Procedure 2 Assign service prole and policies
Cisco UCS has the ability to assign a service profile directly to a specific
server, pre-provision an unused chassis slot, assign the profile to a pool of
servers, or assign the profile to a physical blade server later.
Step 1: In the navigation pane, click the Equipment tab, and then click the
Chassis# from which you want to select the server.
Step 2: Expand Servers, and then click the server you want. By default, the
General tab displays.
Step 3: On the General page, in the Actions section, click the Associate
Service Profile link.
Step 4: In the Associate Service Profile window, select the service profile
from the list of available service profiles, and then click OK. This associates
the service profile to the selected server.
48
Deployment Details February 2013 Series 48
Step 5: If you want to check the progress on the service profile that is being
applied on the server, in the work pane, click the FSM tab. When progress
status reaches 100%, it completes the service profile association to a server.
Step 6: After the service profile is applied to a server, you can now boot
the server to install an operating system. The operating system installation
media is available by either locally attached removable media, or KVM
Console Virtual Media.
For further details on how to install VMware on a server, please
refer to Cisco SBAData Center Virtualization with UCS, Nexus
1000V and VMware Deployment Guide.
Reader Tip
The installation begins as is typical for the given operating system.
Creating a Service Profile for SAN Boot
1. Create service profile for SAN boot
2. Associate server to service profile
Process
Booting service profiles directly from a Fibre Channel SAN can provide key
advantages for ensuring server and application availability. With all operat-
ing system files and application data specific to the server stored on the
SAN, your organization benefits from SAN disk redundancy and backup
practices. This approach works in conjunction with the hardware indepen-
dence provided by Cisco UCS-specific constructs such as shared pools of
Ethernet and Fibre Channel addressing. Together, these attributes provide
the ability to move a service profile among blade servers within the system
programmatically, with no physical intervention required. This concept is
known as stateless computing.
Fibre Channel uses World Wide Node Names (WWNN) and World Wide Port
Names (WWPN) to communicate over the SAN. This process illustrates how
to create a new service profile for SAN boot based on the existing example
profile that you created in the previous process, Creating an Initial Boot
Service Profile for Local Boot.
Procedure 1 Create service prole for SAN boot
In this procedure, you clone the service profile that you created in the previ-
ous process, Creating an Initial Boot Service Profile for Local Boot.
Step 1: On the Servers tab in the navigation pane, right-click the name of
the profile you created in the previous process (Example: Servers_Local_
Disk), and then choose Create a Clone.
Step 2: In the Clone Name box, enter a name that clearly identifies the
profile as a SAN boot server instance (Example: Servers_SAN_Boot), and
then click OK.
49
Deployment Details February 2013 Series 49
Step 3: On the Servers tab in the navigation pane, click on the service
profile you created in the previous step.
Step 4: Click the Storage tab, and then click the vHBAs tab. Under the
Actions pane, click Change Local Disk Configuration Policy.
Step 5: In the Change Local Disk Configuration Policy window, in the Select
the Local Disk Configuration Policy list, select the No_Disk configuration
policy you created in Procedure 1 Create local disk configuration policy,
and then click OK.
Step 6: Click the Boot Order tab in the work pane, and then in the Actions
area, click Modify Boot Policy.

Step 7: In the Modify Boot Policy window, under Boot Policy list, select the
policy created for SAN boot in Procedure 3 Create a SAN boot policy, and
then click OK. This assigns the new boot policy to the profile.
After you select the new boot policy, the work pane shows the new boot
order information, including the correct target LUN ID and WWPN number.
Procedure 2 Associate server to service prole
After the service profile is created and boot policy is assigned, associate the
service profile to an open server on the chassis.
Step 1: In the navigation pane, click the Equipment tab, and then click the
Chassis# from which you want to select the server.
Step 2: Expand Servers, and then click the server you want. By default, the
General tab displays.
Step 3: On the General page, in the Actions section, click the Associate
Service Profile link.
50
Deployment Details February 2013 Series 50
Step 4: In the Associate Service Profile window, select the service profile
from the list of available service profiles, and then click OK. This associates
the service profile to the selected server.
Step 5: If you want to check the progress on the service profile that is being
applied on the server, in the work pane, click the FSM tab. When progress
status reaches 100%, it completes the service profile association to a server.
Step 6: After the service profile is applied to a server, you can now boot
the server to install an operating system. The operating system installation
media is available by either locally attached removable media, or KVM
Console Virtual Media.
For further details on how to install VMware on a server, please
refer to Cisco SBA Data Center Virtualization with UCS, Nexus
1000V and VMware Deployment Guide.
Reader Tip
The installation begins as is typical for the given operating system.
Step 7: When you choose a target disk destination for the installation,
ensure that the new LUN 0, accessible over the Fibre Channel SAN, is
selected.
Step 8: If you want, you can provision the SAN to expose multiple LUNs to a
given initiator. For example, you can use separate LUNs to house operating
system boot files and files that contain application-specific data or database
contents. In a hypervisor environment, a LUN specific to an individual profile
is presented as a boot LUN. A larger LUN, accessible to multiple initiators, is
used to house virtual machinespecific files. In this way, multiple virtualized
servers can access the virtual machine files.
Creating Multiple Service Profiles through Templates
1. Create a service profile template
2. Create a service profile from a template
Process
Service profile templates are one of the ways to simplify the creation of new
service profiles. The template approach ensures that consistent policies
within the system are applied to a given service or application by using the
same basic parameterssuch as the number of vNICs and vHBAsand
with identity information drawn from the same pools. These templates may
be configured as one of two types of service profile templates:
Initial templatesA service profile created from an initial template
initially inherits all the properties of the template, but after you create the
profile, it is no longer connected to the template. If any changes were to
be made to one or more profiles created from this template, you must
change each profile individually.
Updating templatesA service profile created from an updating
template inherits all of the properties of the template and remains
connected to the template. Any change to the template automatically
updates the service profiles created from the template. The updating
template feature is a powerful tool for managing updates to multiple
servers with minimal administrative overhead.
The following procedures describe how to create a service profile template
and then create a service profile from the template.
51
Deployment Details February 2013 Series 51
Procedure 1 Create a service prole template
Step 1: In the Cisco UCS Manager navigation pane, click the Servers tab,
expand Service Profile Templates, and then click the organization root.
Step 2: In the work pane, on the General tab, click Create Service Profile
Template.
Step 3: In the Create Service Profile Template window, enter the Name of
the template.
Step 4: Verify that the Initial Template option (default value) is selected.
Step 5: In the UUID Assignment list, choose an existing UUID pool, and
then click Next.
Step 6: Follow the steps in Procedure 1, Create Service Profile for Local
boot, to fill all required fields for the Storage, Networking, Zoning, vNIC/
vHBA Placement, Server Boot Order, and Maintenance Policy pages.
The difference between creating a service profile versus creating a service
profile template is that the template only allows you to choose a server pool
in the Server Assignment window, but not for the individual blade server.
Step 7: Click Next.
Step 8: On the Operational Policies page, leave the default settings, and
then click Finish.
52
Deployment Details February 2013 Series 52
Procedure 2 Create a service prole from a template
Step 1: In Cisco UCS Manager, click the Servers tab in the navigation pane,
expand Service Profile Templates, and then click the organization where
the new service profile template was created earlier under root.
Step 2: Right-click the service profile template from which you want to
create the profiles, and then click Create Service Profiles From Template.
Step 3: In the Create Service Profiles from Template window, enter a
Naming Prefix for the new profiles, enter the Number of profiles you want to
create (or leave the default value of 2), and then click OK.
Step 4: On the message Successfully created service profiles from
template, click OK.
Step 5: In the navigation pane under Servers > Service Profiles > root,
verify that your new service profiles were created.
This completes the creation of service profiles from a service profile
template.
53
Deployment Details February 2013 Series 53
Cisco UCS C-Series Rack-Mount Server
This module covers deploying the Cisco UCS C-Series Rack-Mount Server.
This module includes information on initial system setup and basic con-
figuration to prepare your server to communicate over Ethernet and FCoE
using Cisco Integrated Management Controller (CIMC) to configure server
settings. This module also includes details on integrating the Cisco UCS
C-Series server with the Cisco Unified Computing System and allowing the
server to be managed by Cisco UCS Manager. CIMC is the management
service for the Cisco UCS C-Series servers. CIMC runs within the server
and allows you to use a web-based GUI or SSH-based CLI to access, config-
ure, administer, and monitor the server. Almost all tasks can be performed
in either interface, and the results of tasks performed in one interface are
displayed in the other.
Cisco UCS C-Series Rack-Mount Servers may be connected to the Cisco
SBA data center infrastructure using available interfaces on the Cisco
Nexus 5500UP Series Switches or through the Cisco Nexus 2000 Series
Fabric Extenders. Switching access or trunk port modes may be configured
according to the settings appropriate for the installed operating system.
Details for data center core port configurations are covered in the Cisco
SBAData Center Deployment Guide.
The final process in this module details how the Cisco UCS C-Series server
can be integrated into the Cisco Unified Computing System and be man-
aged by the same Cisco UCS Manager that controls the UCS B-Series
blade servers by connecting to a UCS Fabric Interconnect through a Cisco
Nexus 2232PP Fabric Extender. This integration provides a single manage-
ment interface to Cisco UCS B-Series and C-Series servers.
Details on supported C-Series servers and network adapter
cards for UCS integration with Cisco UCS Manager 2.1(1a), as well
as the installation instructions for your specific C-Series server,
can be found at:
http: //www.cisco.com/en/US/docs/unified_computing/ucs/c-
series_integration/ucsm2.1/b_UCSM2-1_C-Integration.html
Reader Tip
If you are deploying your Cisco UCS C-Series servers for UCS-managed
integration, complete the following processes only:
Configuring Cisco Integrated Management Controller
Updating Firmware for Cisco UCS C-Series Server
Integrating Cisco UCS C-Series into the Cisco UCS Manager
Environment
Configuring Cisco Integrated Management Controller
1. Configure management access
Process
Procedure 1 Congure management access
To access the CIMC controller remotely, you must either statically assign
a management IP address or have a DHCP server servicing the VLAN or
subnet to which the server is connected. This procedure assigns a static IP
address to the server and requires the following information:
IP address10.4.63.66
Subnet mask255.255.255.0
Default gateway10.4.63.1
Password
Step 1: Connect a keyboard, video display, and mouse to the server for the
initial setup, and then power up the server.
54
Deployment Details February 2013 Series 54
Step 2: When the server boots up, you have the option to set up BIOS, boot
menu, network boot, and CIMC Configuration. While in BIOS, press F8 to
start CIMC Configuration.
Step 3: Under NIC mode, press the Spacebar. This enables Dedicated.
The10/100 management ports included on the server are used to access
CIMC. The management ports are connected to the out-of-band Ethernet
management network, which is detailed in the Cisco SBAData Center
Deployment Guide.
To manage the Cisco UCS C-Series server as a standalone
server using dedicated Ethernet ports for CIMC access, choose
NIC mode Dedicated. To access CIMC via Cisco Card, or to man-
age the server when connected to a Cisco UCS fabric intercon-
nect, see the following guide for more information:
http: //www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/
C240/install/install.html#wp1400933
Details for managing a Cisco UCS C-Series server with Cisco
UCS Manager appear later in this guide, in the Integrating
Cisco UCS C-Series into the Cisco UCS Manager Environment
process.
Tech Tip
Step 4: Under IPV4 (Basic), press the Spacebar. This action disables the
default DHCP enabled. Then enter CIMC IP, Subnetmask, and the default
Gateway.
Step 5: Under NIC redundancy, verify that Active-Standby is enabled.
If you are using a server with a single management NIC, like the
Cisco C200 Series, select a NIC redundancy of None.
Tech Tip
Step 6: Under Default User (Basic), enter a default password. The default
username is admin.
Step 7: Press F10. This saves the settings.
Step 8: Press F5 (Refresh). This reflects the latest configuration.
Step 9: Wait until the new settings appear, and then press Esc to exit and
reboot the server.
55
Deployment Details February 2013 Series 55
Configuring LSI RAID
1. Configure the LSI RAID adapter
Process
If you are going to connect your Cisco UCS C-Series Server to a Cisco UCS
Fabric Interconnect and manage it with Cisco UCS Manager, you may skip
this process and continue with the next process Updating Firmware for
Cisco UCS C-Series Server.
Procedure 1 Congure the LSI RAID adapter
The LSI Integrated Mirroring feature is used to safeguard critical information
by mirroring a set of data on two or more disks. In the event of a drive failure,
data can be recovered from the mirrored drive, and the failed drive can be
replaced. The server used in this lab setup has two identical 600 GB hard
drives with one optional LSI RAID controller. This procedure configures the
two drives for RAID 1 (mirroring).
The following setup uses the LSI Integrated Mirroring feature. For
a more elaborate RAID setup, see more specific LSI documenta-
tion at:
http: //www.lsi.com
Reader Tip
Step 1: After the server has started the boot process, look for the screen as
shown in the figure below. When you see this screen, press Ctrl-H.
This guide was tested with LSI MegaRAID. Servers provisioned
with other RAID controllers, such as the LSI 1064E and LSI 1068E
RAID controllers, use Ctrl+C to access the LSI RAID config utility
setup screens.
Tech Tip
Step 2: Choose the adapter, and then select Start.
Step 3: On the MegaRAID BIOS Config Utility Physical Configuration
window, select Configuration Wizard.
56
Deployment Details February 2013 Series 56
Step 4: On the Configuration Wizard, select New Configuration. This option
deletes the previous configuration and creates a new configuration. Click
Next.
Step 5: On the MegaRAID BIOS utility confirm page, a warning message
will be displayed, stating that you are about to delete all data from all virtual
drives. Select Yes.

Step 6: In the Configuration wizard, select Automatic Configuration, and
in the Redundancy list, choose Redundancy when possible, and then click
Next. If two drives are available, WebBIOS creates a RAID1 configuration.
Step 7: In the Configuration Preview page, notice that the RAID level of the
logical drive is RAID1. Select Accept.
Step 8: On the confirm page, select Yes. The configuration is saved.
57
Deployment Details February 2013 Series 57
Step 9: You will be prompted with a confirmation page, stating that all data
on the new Virtual Drive will be deleted and the virtual drive will be initial-
ized. Select Yes. Once the virtual drive has been initialized, you will see the
following screen.
Step 10: On the MegaRAID BIOS Config Utility Virtual Drives window, select
Home. You return to main WebBIOS config utility window.
Step 11: Select Exit. On the exit confirmation page, select Yes.
Step 12: Reboot the server. It recognizes the new RAID configuration.
Updating Firmware for Cisco UCS C-Series Server
1. Configure virtual media
2. Upgrade UCS C-Series server firmware
Process
It is recommended that you update your Cisco UCS C-Series servers with
the latest firmware and BIOS. The Cisco UCS P81E Virtual Interface Card
requires Management Controller Firmware version 1. 2. X or later. Support
for configuration of FCoE over network interface virtualization (NIV) needs
Management Controller Firmware version 1.4.1 or later.
Support for integrating a Cisco UCS C-Series server with Cisco UCS to be
managed by Cisco UCS Manager running release 2.1(1a) or later is listed in
Table 7 below.
Table 6 - Cisco UCS C Series server firmware used in Cisco SBA
Server type
Host Upgrade
utility version Virtual interface card type
Cisco UCS C220 M3 1.4(7a)1 Cisco UCS VIC 1225
Cisco UCS C240 M3 1.4(7b)1 Cisco UCS VIC 1225
Cisco UCS C200 M2 1.4(3p)5 Cisco UCS P81E VIC
Cisco UCS C210 M2 1.4(3p)5 Cisco UCS P81E VIC
Table 7 - Cisco UCS C-Series integration with UCS Manager firmware
requirements
Server model
Integration
type
CIMC
version BIOS version VIC firmware
Cisco UCS
C220 M3
Single wire 1.4(6) 1.4(7a) 2.1(0.457a)
Cisco UCS
C240 M3
Single wire 1.4(6) 1.4(7a) 2.1(0.457a)
Cisco UCS
C200 M2
Dual wire 1.4(3c)
minimum
2.0(2g)
Cisco UCS
C210 M2
Dual wire 1.4(3c)
minimum
2.0(2g)
58
Deployment Details February 2013 Series 58
Details on supported Cisco UCS C-Series servers, network
adapter cards, and firmware requirements for Cisco UCS inte-
gration, as well as the installation instructions for your specific
C-Series server, can be found at:
http: //www.cisco.com/en/US/products/ps11736/products_
installation_and_configuration_guides_list.html
Reader Tip
Note that Cisco UCS Manager single-wire-management integration requires
a Cisco UCS Virtual Interface Card 1225.
Procedure 1 Congure virtual media
Step 1: In a browser, enter the IP address you configured earlier in Step 4
of the Configure management access procedure under the Configuring
Cisco Integrated Management Controller process. This opens the CIMC
login page.
You receive a Security Certificate warning in your browser on initial login
before you can connect to the login screen.
Step 2: Click Accept. This acknowledges the certificate warning.
Step 3: Log in by using the default username admin and the password you
configured earlier.
You can launch the CIMC GUI and manage the server from any
remote host that meets these minimum requirements: Java 1.6
or later, HTTP and HTTPS enabled, and Adobe Flash Player 10 or
later.
Tech Tip
Step 4: On the Server tab, click Remote Presence.
Step 5: On the Virtual Media tab, verify that Enabled is selected.
If you do not select Enabled, you will receive the error Either
Virtual Media is detached or ... when you try to map a remote
disk.
Tech Tip
Step 6: Click Save Changes.
59
Deployment Details February 2013 Series 59
Procedure 2 Upgrade UCS C-Series server rmware
You can use the Cisco Host Upgrade utility to upgrade the following
firmware:
CIMC
System BIOS
LAN on motherboard
LSI
Cisco UCS Virtual Interface Card
Step 1: Download the Cisco UCS Host Upgrade utility ISO file from www.
cisco.com. The version of Cisco UCS used in this guide is Server Firmware
version 1.4(7a)1 for a Cisco UCS C-Series C220 M3 Rack Server.
Step 2: Locate the ISO file corresponding to the model of your server,
download the file, and store it locally on your hard disk.
Step 3: In the CIMC Console, on the Server tab, click Summary, and then
click Launch KVM Console.
Step 4: In the KVM Console dialog box, select the Virtual Media tab. The
virtual media feature allows for media on your desktop to be available to the
remote host.
Step 5: Click Add Image, and in the Open dialog box, select the Host
Upgrade utility ISO file that you downloaded in Step 2.
60
Deployment Details February 2013 Series 60
Step 6: Select the check box in the Mapped column for the ISO file. Do not
click Exit when complete. Instead, proceed to the next step.
Step 7: In the KVM Console, click the Macros tab, and then select Ctrl-Alt-
Del. The server reboots.
Step 8: During the servers power-on self-test, press F6. Use the arrow
key to select Cisco Virtual CD/DVD, and then press Enter. Do not close the
virtual media screen while it is in use.
After the server boots from the selected device, the following screen is
displayed as the host loads the ISO image from the virtual disk drive.
Step 9: After the server loads the upgrade utility and displays the screen
below, press n to read the Cisco end-user license agreement (EULA), and
then press y to accept the EULA.
61
Deployment Details February 2013 Series 61
Step 10: In the Host Upgrade utility screen, at the Enter Choice prompt,
enter 11 for all of the above. This upgrades CIMC, BIOS, LAN on mother-
board (LOM), LSI, VIC firmware, and Peripheral Component Interconnect
(PCI) adapters.
The firmware upgrade begins, and the status can be monitored as in the
following figure.
Step 11: Once all firmware except the BIOS has been upgraded, the follow-
ing screen indicates that updating the BIOS will power down the server. For
the Updating BIOS will power down the server. This can take few minutes,
do you want to continue (y/n) question, enter y, and then for the Do you
want to automatically power up the server once bios update is completed
(y/n) question, enter y.
Step 12: Once the BIOS upgrade completes, the server power cycles and
boots up. Log in to CIMC to reestablish the connection.
62
Deployment Details February 2013 Series 62
Step 13: Verify under Server Properties that the BIOS Version has been
updated, and under CIMC that the Firmware Version has been updated.
Configuring Ethernet and FCoE Connectivity
1. Configure vNICs
2. Configure vHBAs
Process
If you are going to connect your Cisco UCS C-Series Server to a Cisco UCS
Fabric Interconnect and manage it with Cisco UCS Manager, you may skip
this process and continue with the next process Integrating Cisco UCS
C-Series into the Cisco UCS Manager Environment.
FCoE is an extension of the Fibre Channel SAN onto a lossless Ethernet fab-
ric. This allows you to consolidate NICs and HBAs onto a single converged
network adapter.
The FCoE-connected server is controlled by two drivers for Fibre Channel
and Ethernet, respectively. Fibre Channel traffic over Ethernet is transpar-
ent to the operating system of the server. It operates as a Small Computer
System Interface (SCSI) Initiator running over FCoE acting as if the server
were connected over native Fibre Channel. In the following setup, you
enable the Cisco UCS C-Series server to make use of FCoE capabilities.
This is done by configuring vNICs and vHBAs, which enables the server
to pass Ethernet and Fibre Channel traffic. With the help of adapter virtu-
alization (network interface virtualization), it is possible to create multiple
Ethernet and Fibre Channel adapters. Through Peripheral Component
Interconnect Express (PCIe) virtualization, the adapter shows multiple
Ethernet and Fibre Channel adapters to the server. The server can scan the
PCIe bus and can find all the virtual adapters that have been provisioned.
Figure 9 - Converged infrastructure using FCoE
63
Deployment Details February 2013 Series 63
Procedure 1 Congure vNICs
Step 1: In the CIMC console navigation pane, click the Server tab, and then
click Inventory.
Step 2: On the Network Adapters tab, click the adapter.
Step 3: On the General tab in the tabbed menu below the Adapter Cards
area, verify that FIP Mode is set to Enabled. If the FIP mode is not enabled,
click Modify Adapter Properties, select Enable FIP Mode, and then click
Save Changes. FIP mode ensures that the adapter is compatible with cur-
rent FCoE standards.
Step 4: On the tabbed menu below the Adapter Card area, click the vNICs
tab. In the Host Ethernet Interfaces area, select a vNIC from the table.
Step 5: Click Properties. The vNIC Properties dialog box appears.
Most single operating system installations that have been installed directly
on a server use a single VLAN for server-to-network operation. For a server
environment where multiple VLANs will need to be available to the operating
system, as is the case for VMware ESXi, you use a VLAN mode of Trunk.
Step 6: In the VLAN Mode list, choose Trunk.
The upstream data-center core switch ports to which the two physical ports
of the Cisco UCS P81E VIC or Cisco UCS VIC 1225 adapter are connected
should also be configured to match the VLAN selection as either a single
VLAN or trunk ports. VLAN trunks on the adapter card carry traffic from
all VLANs by default. The upstream data center core switch typically has
VLAN-1 as the native VLAN by default.
64
Deployment Details February 2013 Series 64
Step 7: If you are not passing any data traffic on VLAN-1 to the host, leave
Default VLAN set to NONE.
Step 8: Repeat Step 4 through Step 7 for the second vNIC, and ensure that
the vNIC properties are the same as you set in Step 6 and Step 7.
Procedure 2 Congure vHBAs
The Cisco UCS P81E VIC and Cisco UCS VIC 1225 converged network
adapters include two physical 10Gigabit Ethernet ports and have two
vHBAs created by default. The two vHBAs labeled as fc0 and fc1 are con-
nected to the upstream data-center core switches Cisco Nexus 5500-A and
Nexus 5500-B, respectively, as configured in the Cisco SBAData Center
Deployment Guide. VSAN allows logical partitioning of the physical SAN
infrastructure. It is recommended that you dedicate a separate VLAN for
FCoE traffic corresponding to each VSAN. The following table shows the
FCoE VLAN for each VSAN as was set up in the Data Center Deployment
Guide.
Table 8 - SBA data center core switch VSAN and FCoE VLAN values
Data center core switch VSAN FCoE VLAN
Cisco Nexus 5500-A 4 304
Cisco Nexus 5500-B 5 305
FCoE Initialization Protocol (FIP) is the control plane protocol used to
establish the FCoE virtual link between the Ethernet-attached Fibre Channel
node and the FCoE switch. FIP performs FCoE VLAN discovery by sending
untagged frames to its neighbor. It provides a way for the host to log into and
log out from the FCoE switch. Note that FIP VLAN discovery is not supported
by Linux or VMware ESX server. Because of this, the FCoE VLAN has to
be configured on the vHBA from the CIMC console. More details about
the Fibre Channel and FCoE setup can be found in the Cisco SBAData
Center Deployment Guide.
Step 1: In the Adapter Cards area, select the available adapter card.
Step 2: On the tabbed menu below the Adapter Card area, click the vHBAs
tab, and in the Host Fibre Channel Interfaces area, select the vHBA labeled
fc0 from the table, and then click Properties.
65
Deployment Details February 2013 Series 65
Step 3: In the Default VLAN field, select the second option button, and then
enter the FCoE VLAN, which in this case is VLAN 304 (as shown in Table 8
earlier in this procedure).
Step 4: Click Save Changes.
Step 5: In the Host Fibre Channel Interfaces area, select the vHBA labeled
as fc1 from the table, and then click Properties.
Step 6: In the Default VLAN field, select the second option button, and then
enter the FCoE VLAN, which in this case is VLAN 305. This value must match
with the FCoE VLAN configured in the upstream connected switch.
Step 7: Click Save Changes.
Step 8: In the navigation pane, click the Server tab, click Summary, and
then in the work pane, under Actions, click Power Cycle Server. You must
reboot the server for changes to take effect.
66
Deployment Details February 2013 Series 66
Step 9: On the Power cycle the server? message, click OK.
After the server reboots, it is ready to have an operating system installed.
How to configure a VMware environment is explained in detail
in the Cisco SBA Data Center Virtualization with UCS, Nexus
1000V and VMware Deployment Guide.
Reader Tip
Integrating Cisco UCS C-Series into the Cisco UCS Manager
Environment
1. Connect Cisco Nexus 2232PP FEX
2. Configuring dual-wire management
3. Configuring single-wire management
4. Associate service profile to server
Process
The previous process for the Cisco UCS C-Series prepared the server for
connectivity directly to the Cisco Nexus 2000 Series Fabric Extenders and
Nexus 5000 Series Switches data center foundation, where the C-Series
server would be managed as a standalone device. This section describes
deploying infrastructure to allow the C-series server to connect to the fabric
interconnects of the Cisco UCS B-Series environment and to allow you to
manage both the B-Series and C-Series servers from Cisco UCS Manager
and transport traffic through the Fabric Interconnect.
Details on supported Cisco UCS C-Series servers and network
adapter cards for Cisco UCS integration, as well as the installation
instructions for your specific C-Series server, can be found at:
http: //www.cisco.com/en/US/products/ps11736/products_
installation_and_configuration_guides_list.html
Reader Tip
This design guide is using Cisco UCS Manager Release 2.1(1a). With UCS
Manager Release 2.1(1a) and later, there are now two modes of managing the
UCS C-Series server connected to the fabric interconnects:
Single-wire-managementRequires the Cisco UCS VIC1225 Virtual
Interface Card, which can carry both data traffic and management traffic
on the same interface cable. The Cisco UCS VIC 1225 is supported
on the Cisco UCS C-Series M3 model servers and select M2 model
servers.
Dual-wire-managementIs supported in the Cisco UCS Manager
release 2.1 and earlier releases. Shared LAN on Motherboard (LOM)
ports on the rack server are used exclusively for carrying management
traffic. A separate cable connected to one of the ports on the PCIe card
or Cisco UCS P81E Virtual Interface Card carries the data traffic. The
Cisco UCS VIC 1225 supports dual-wire-management as well.
67
Deployment Details February 2013 Series 67
The Cisco UCS C-Series servers connect to the UCS Fabric Interconnects
via Cisco Nexus 2232PP Fabric Extenders (FEX), as shown in Figure 10. The
C-Series server requires four connections to the FEX: two management
links and two data traffic links. The Nexus 2232PP FEX allows higher density
server connectivity and can support both data and management traffic flows
to the fabric. In this design, the Nexus 2232PP FEX can connect up to 16
UCS C-Series servers.
Figure 10 - Cisco UCS C-Series server to UCS Fabric connection details
2
2
0
7
Cisco UCS
Fabric-A
Cisco UCS
Fabric-B
Cisco
Nexus 2232PP
FEX-A
Cisco
Nexus 2232PP
FEX-B
Fabric
Interconnect
Cisco UCS
C-Series Dual-wire
Managed Server
UCS
B-Series
Chassis
10GbE Ethernet, FCoE, and Management Traffic
10GbE Ethernet and FCoE Traffic
1GbE Management Traffic
FEX to Fabric Uplinks
Cisco UCS C-Series
Single-wire Managed Server
The quantity of FEX to fabric uplinks must be equal to or greater than the
minimum number of links specified in the Chassis Discovery Policy set in
Step 3 of the Configure fabric-to-I/O-module links procedure earlier in this
guide.
Procedure 1 Connect Cisco Nexus 2232PP FEX
Step 1: Connect FEX uplink ports to fabric interconnects, as follows:
Connect FEX-A uplinks p1 through p4 to Fabric Interconnect-A (FI-A).
Connect FEX-B uplinks p1 through p4 to Fabric Interconnect-B (FI-B).
You can use up to 8 FEX uplinks to a fabric interconnect for maximum
throughput, and a minimum of 2 is required for the Chassis Discovery Policy
set in Step 3 of the Configure fabric-to-I/O-module links procedure earlier
in this guide. It is recommended that for maximum virtual NIC scalability, that
a FEX connect to the fabric interconnect with all FEX uplink ports included in
a group of 8 fabric interconnect ports; that is all FEX uplink ports connect to
fabric interconnect ports 1-8, or 9-16, or 17-24, etc.
The number of vNICs and vHBAs that can be defined on virtual
interface cards in the servers connected to the FEX is dependent
on the number of uplinks and the connectivity to the fabric inter-
connect. For more information see:
http: //www.cisco.com/en/US/docs/unified_computing/ucs/c-series_
integration/ucsm2.1/b_UCSM2-1_C-Integration_chapter_01.html#ref
erence_7F381038303B4825ACD303765905086A
Tech Tip
Step 2: Using a browser, access the cluster IP address 10.4.63.31 that you
assigned during initial setup in Procedure 3 Complete initial fabric intercon-
nect setup of the Completing the Initial System Setup process, and then
choose Launch. The Cisco UCS Manager Java application downloads.
Step 3: In the navigation pane, click the Equipment tab, and then expand
Fabric Interconnects > Fabric Interconnect A > Fixed Module > Ethernet
Ports.
Objects are displayed representing each of the physical ports on the base
fabric interconnect system. This deployment uses ports 13, 14, 15 and 16 of
fabric interconnect ports to FEX.
68
Deployment Details February 2013 Series 68
Step 4: Right-click the selected port or group of ports, and then choose
Configure as Server Port.
Step 5: On the Successfully Configured message, click OK.
Step 6: Repeat Step 3 and Step 4 on Fabric Interconnect B.
Step 7: Connect power to FEX-A and FEX-B.
Step 8: In the navigation pane, expand Equipment > Rack-Mounts > FEX.
The Cisco Nexus 2232PP FEXs should appear with automatically generated
FEX numbering. In the screen below the new FEXs are FEX 3 and FEX 4.
It will take a few minutes for the FEX to power up, download software from
the fabric interconnect, and report to the system. If you click a FEX, the
status in the work pane should appear as Operable.
69
Deployment Details February 2013 Series 69
Procedure 2 Conguring dual-wire management
If you will be configuring for single-wire-management you can skip this
procedure, and proceed to the next procedure.
Dual-wire-management is supported in the Cisco UCS Manager release 2.1
and releases earlier than 2.1 which meet the adapter card and Cisco UCS
C-Series server requirements. Shared LAN on Motherboard (LOM) ports
on the rack server are used exclusively for carrying management traffic.
A separate cable connected to one of the ports on the PCIe card or Cisco
UCS P81E Virtual Interface Card carries the data traffic. You must ensure
that the Cisco UCS C-Series server CIMC settings are set to factory default
prior to attempting dual-wire management integration.
For more information on dual-wire-management and support on
releases prior to Cisco UCS Manager 2.1 please see:
http: //www.cisco.com/en/US/products/ps11736/products_
installation_and_configuration_guides_list.html
Reader Tip
In this procedure, you connect the Cisco UCS C-Series server management
traffic path to FEX-A and FEX-B deployed in Procedure 1, as shown in Figure
10. In Step 1 and Step 2, you must use Cisco UCS C-Series Ethernet LOM
ports for server management traffic, and not the CIMC management ports.
Step 1: Insert one GLC-T transceiver into a port of FEX-A. You can use
any port on the FEX. Connect an RJ-45 Ethernet cable between the 1-Gb
Ethernet LOM port Eth 1 on the rear panel of the server and the transceiver
that you inserted in FEX-A.
Step 2: Insert one GLC-T transceiver into a port of FEX-B. You can use
any port on the FEX. Connect an RJ-45 Ethernet cable between the 1-Gb
Ethernet LOM port Eth 2 on the rear panel of the server and the transceiver
that you inserted in FEX-B.
Next, connect the data traffic path to FEX-A and FEX-B deployed in
Procedure 1, as shown in Figure 10.
Step 3: Connect a 10-Gb Small Form-Factor Pluggable Plus (SFP+) cable
between the 10-Gb adapter card Port 1 in the server and a port on FEX-A.
You can use any port on the FEX.
Step 4: Connect a 10-Gb SFP+ cable between the 10-Gb adapter card Port
2 in the server and a port on FEX-B. You can use any port on the FEX.
Step 5: Power on or reboot the server. Cisco UCS Manager dynamically
discovers the server.
Step 6: In the navigation pane, expand Equipment > Rack-Mounts >
Servers. Server 2 is listed.
Step 7: Click the server (Example: Server 2). The connectivity for the Cisco
UCS C-Series Server 2 is shown in the work pane.
70
Deployment Details February 2013 Series 70
Step 8: Click the General tab. The operational status and the properties of
the physical Server 2 are displayed.
Procedure 3 Conguring single-wire management
Single-wire-management requires the Cisco UCS VIC 1225, which can carry
both data traffic and management traffic on the same interface cable. The
Cisco UCS VIC 1225 is supported on the Cisco UCS C-Series M3 model
servers and select M2 model servers. You must ensure that the Cisco UCS
C-Series server CIMC settings are set to factory default prior to attempting
single-wire management integration.
In this deployment, you connect one of the Cisco UCS VIC 1225 adapter
10-Gb Ethernet interfaces to each FEX, FEX-A and FEX-B, deployed in
Procedure 1, as shown in Figure 10.
Step 1: Connect a 10-Gb Small Form-Factor Pluggable Plus (SFP+) cable
between the 10-Gb adapter card Port 1 in the server and a port on FEX-A.
You can use any port on the FEX.
Step 2: Connect a 10-Gb SFP+ cable between the 10-Gb adapter card Port
2 in the server and a port on FEX-B. You can use any port on the FEX.
Step 3: Power on or reboot the server. Cisco UCS Manager dynamically
discovers the server.
Step 4: In the navigation pane, expand Equipment > Rack-Mounts >
Servers. Server 1 is listed.
Step 5: Click Server 1. The connectivity for the Cisco UCS C-Series Server
1 is shown in the work pane.
71
Deployment Details February 2013 Series 71
Step 6: Click the General tab. The operational status and the properties of
the physical Server 1 are displayed.
Procedure 4 Associate service prole to server
You can now attach a previously defined service profile to the Cisco UCS
C-Series server the same way you are able to do with a Cisco UCS B-Series
server, as detailed in Procedure 2, Associate server to service profile.
Step 1: In the work pane, click the General tab, and then, in the Actions
field, click Associate Service Profile.
Step 2: Select a service profile for your server from the list of available
service profiles, and then click OK. The physical server blade boots up with
the assigned service profile.
This completes the Cisco UCS C-Series server integration to Cisco UCS
Manager environment. You can now build and assign profiles for C-Series
servers the same way as a B-Series server, as detailed earlier in this guide.
72
Appendix A: Product List February 2013 Series 72
Appendix A: Product List
Data Center Core
Functional Area Product Description Part Numbers Software
Core Switch Cisco Nexus 5596 up to 96-port 10GbE, FCoE, and Fibre Channel SFP+ N5K-C5596UP-FA NX-OS 5. 2(1)N1(1b)
Layer 3 License
Cisco Nexus 5596 Layer 3 Switching Module N55-M160L30V2
Cisco Nexus 5548 up to 48-port 10GbE, FCoE, and Fibre Channel SFP+ N5K-C5548UP-FA
Cisco Nexus 5548 Layer 3 Switching Module N55-D160L3
Ethernet Extension Cisco Nexus 2000 Series 48 Ethernet 100/1000BASE-T (enhanced) Fabric
Extender
N2K-C2248TP-E
Cisco Nexus 2000 Series 48 Ethernet 100/1000BASE-T Fabric Extender N2K-C2248TP-1GE
Cisco Nexus 2000 Series 32 1/10 GbE SFP+, FCoE capable Fabric Extender N2K-C2232PP-10GE
Data Center Services
Functional Area Product Description Part Numbers Software
Application Resiliency Cisco ACE 4710 Application Control Engine 2Gbps ACE-4710-02-K9 A5(1. 2)
Cisco ACE 4710 Application Control Engine 1Gbps ACE-4710-01-K9
Cisco ACE 4710 Application Control Engine 1Gbps 2-Pack ACE-4710-2PAK
Cisco ACE 4710 Application Control Engine 500 Mbps ACE-4710-0. 5-K9
Firewall Cisco ASA 5585-X Security Plus IPS Edition SSP-40 and IPS SSP-40 bundle ASA5585-S40P40-K9 ASA 9.0(1)
IPS 7.1(6) E4
Cisco ASA 5585-X Security Plus IPS Edition SSP-20 and IPS SSP-20 bundle ASA5585-S20P20X-K9
Cisco ASA 5585-X Security Plus IPS Edition SSP-10 and IPS SSP-10 bundle ASA5585-S10P10XK9
Storage Network Extension
Functional Area Product Description Part Numbers Software
Fibre-channel Switch Cisco MDS 9148 Multilayer Fibre Channel Switch DS-C9148D-8G16P-K9 NX-OS 5.0(8)
Cisco MDS 9124 Multilayer Fibre Channel Switch DS-C9124-K9
73
Appendix A: Product List February 2013 Series 73
Computing Resources
Functional Area Product Description Part Numbers Software
UCS Fabric Interconnect Cisco UCS up to 48-port Fabric Interconnect UCS-FI-6248UP 2.1(1a)
Cisco UCS Release
Cisco UCS up to 96-port Fabric Interconnect UCS-FI-6296UP
UCS B-Series Blade
Servers
Cisco UCS Blade Server Chassis N20-C6508 2.1(1a)
Cisco UCS Release
Cisco UCS 8-port 10GbE Fabric Extender UCS-IOM2208XP
Cisco UCS 4-port 10GbE Fabric Extender UCS-IOM2204XP
Cisco UCS B200 M3 Blade Server UCSB-B200-M3
Cisco UCS B200 M2 Blade Server N20-B6625-1
Cisco UCS B250 M2 Blade Server N20-B6625-2
Cisco UCS 1280 Virtual Interface Card UCS-VIC-M82-8P
Cisco UCS M81KR Virtual Interface Card N20-AC0002
UCS C-Series Rack-mount
Servers
Cisco UCS C220 M3 Rack Mount Server UCSC-C220-M3S 1.4.6
Cisco UCS CIMC
Release
Cisco UCS C240 M3 Rack Mount Server UCSC-C240-M3S
Cisco UCS C200 M2 Rack Mount Server R200-1120402W
Cisco UCS C210 M2 Rack Mount Server R210-2121605W
Cisco UCS C250 M2 Rack Mount Server R250-2480805W
Cisco UCS 1225 Virtual Interface Card Dual Port 10Gb SFP+ UCSC-PCIE-CSC-02
Cisco UCS P81E Virtual Interface Card Dual Port 10Gb SFP+ N2XX-ACPCI01
74
Appendix B: Changes February 2013 Series 74
Appendix B: Changes
This appendix summarizes the changes to this guide since the previous
Cisco SBA series:
We improved process and step flow in the Data Center Core Network
Infrastructure section.
We upgraded the Cisco UCS Manager on the Cisco UCS Fabric
Interconnects to release 2.1(1a), and we added Cisco UCS B200 M3
Blade Server with the modular LAN on Motherboard (mLOM) based on
the new Cisco UCS VIC 1240 Virtual Interface Card.
We added FCoE uplinks as an option in both the data center core and on
the Cisco UCS Fabric Interconnects.
We redesigned the Cisco UCS B-Series server process and proce-
dures, to streamline address pool creation, profile creation, and template
creation. We added Cisco UCS Manager domain identification, to
address pool creation.
We removed the Cisco UCS 6100 Series Fabric Interconnects and Cisco
UCS 2100 Series Fabric Extenders.
We added Cisco UCS C-Series C220 M3 and C240 M3 rack mount
servers to the Cisco SBA data center along with the new Cisco UCS VIC
1225.
We updated the Cisco UCS C-Series server LSI RAID controller configu-
ration, to use the more recent LSI MegaRAID controller.
We added Cisco UCS Manager single-wire-management to the pro-
cess for Cisco C-Series server integration to the Cisco UCS Manager
environment.
ALL DESIGNS, SPECIFICATIONS, STATEMENTS, INFORMATION, AND RECOMMENDATIONS (COLLECTIVELY, DESIGNS) IN THIS MANUAL ARE PRESENTED AS IS, WITH ALL FAULTS. CISCO AND ITS SUPPLiERS DISCLAIM ALL WARRANTIES, INCLUDING, WITH-
OUT LIMITATION, THE WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE
FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THE DESIGNS, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE DESIGNS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USERS ARE SOLELY RESPONSIBLE FOR THEIR APPLICATION OF THE DESIGNS. THE DESIGNS DO NOT CONSTITUTE THE TECHNICAL
OR OTHER PROFESSIONAL ADVICE OF CISCO, ITS SUPPLIERS OR PARTNERS. USERS SHOULD CONSULT THEIR OWN TECHNICAL ADVISORS BEFORE IMPLEMENTING THE DESIGNS. RESULTS MAY VARY DEPENDING ON FACTORS NOT TESTED BY CISCO.
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content
is unintentional and coincidental.
2013 Cisco Systems, Inc. All rights reserved.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its afliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their
respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
Please use the feedback form to send comments
and suggestions about this guide.
Feedback
SMART BUSINESS ARCHITECTURE
Americas Headquarters
Cisco Systems, Inc.
San Jose, CA
Asia Pacific Headquarters
Cisco Systems (USA) Pte. Ltd.
Singapore
Europe Headquarters
Cisco Systems International BV Amsterdam,
The Netherlands
Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco Website at www.cisco.com/go/offices.