0% found this document useful (0 votes)
793 views5 pages

Excel Sheet For Beams

The document provides information to design a simply supported beam, including: 1) Loads applied to the beam from slabs on both sides, totaling 36.34 KN/m. 2) Properties of the beam including a clear span of 4m, effective span of 4.225m, and required flexural strength of 81.09 KN-m. 3) Calculations to determine the required steel reinforcement for a singly reinforced concrete beam design with a depth of 252mm.

Uploaded by

Hassan Ali Sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
793 views5 pages

Excel Sheet For Beams

The document provides information to design a simply supported beam, including: 1) Loads applied to the beam from slabs on both sides, totaling 36.34 KN/m. 2) Properties of the beam including a clear span of 4m, effective span of 4.225m, and required flexural strength of 81.09 KN-m. 3) Calculations to determine the required steel reinforcement for a singly reinforced concrete beam design with a depth of 252mm.

Uploaded by

Hassan Ali Sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

si units

1 loading on beam from slab


i from left panel lx (m) 4 ly (m) 5
material thickness height density load
mm mm kg/m3 kg/m2
R.C.C 150 2400 360
Brick ballast 50 1800 90
pcc 25 2300 57.5
tiles 0 1930 0
partition 5 3.04 1930 0.001467
others 100 100
live load 300 300
1209.002 (kg/m2)
4
1.333333333
1612.002347 (kg/m)
ii from right panel lx (m) 4 ly (m) 5
material thickness height density load
mm m kg/m3 kg/m2
R.C.C 150 2400 360
Brick ballast 50 1800 90
pcc 25 2300 57.5
tiles 0 1930 0
partition 0 3.56 1930 0
others 100 100
live load 300 300
1209 (kg/m2)
4
1.730666667
2092.376 (kg/m)
2
thickness of wall 0 mm
height of wall 0 m

0 kg/m
0 KN/m
0.333333333 mm
0.001744 KN/m
factored load
factored load
UDL ON Beam due to wall
assumed depth of beam
clear span of beam (m)
equilent width of slab (m)
factored UDL on beam
UDL on beam due to wall supported by beam
smaller beam
factored UDL on beam
clear span of beam (m) larger beam
equilent width of slab (m)
UDL ON Beam due to slab of upper floor
self weigh of beam
36.342044 KN/m
Beam end condition simply supported
Go to sheet No 2

Total factored UDL on beam
clear span of beam 4 m
effc. span of beam 4.225 m
Wu 36.34204 KN/m
b 225 mm
d' 48 mm
fy 300 Mpa
fc' 30 MPa
40 mm
hmax common 352.0833 mm
hmin defl.crit. 264.0625 mm
h sel. 300 mm
d 252 mm
Mu 81.09103 KN-m
dmin 242.0793 mm
design method
min 0.004667
max 0.027094
if section is singly reinforced
0.085
R 5.675305
0.024567
As 1392.935 mm2
if section is doubly reinforced
As1 0 mm2
a 0
M1 0 KN-m
M2 81.09103 KN-m
As2 0
As 0
fs' #DIV/0!
As2 revised #DIV/0! top steel
simply suopported beam
singly reinforced
use these vaues only for singly
reinforced section
Assuming compression steel is yielding
#DIV/0!
bottom steel
Bottum cover




use these vaues only for singly
reinforced section

You might also like