a-LIFE2 - 0102 - 1004 - 201306 - EN Rev05
a-LIFE2 - 0102 - 1004 - 201306 - EN Rev05
a-LIFE2 - 0102 - 1004 - 201306 - EN Rev05
A_LIFE2_0102_1004_201306_EN
a-LIFE2
0102 1004
1,5 7,5 kW
(The photo of the unit is purely indicative and may vary depending on the model)
Configuration
User frendly
Full integration
< Real savings
<
<
<
a-LIFE2
SUMMARY
1.
RANGE
2.
GENERAL DEsCRiPTioN
3.
ACCEssoRiEs CoMPATiBiLiTY
4.
UNiT DEsCRiPTioN
5.
oPERATiNG LiMiTs
6.
10
7.
FAN PERFoRMANCEs
16
8.
PREssURE DRoP
20
9.
22
23
24
24
25
14. ACCEssoRiEs
31
48
53
Waiver of liability
This publication represents the sole property of Climaveneta.
Any reproduction or disclosure of such is strictly prohibited without the written authorisation of Climaveneta.
This document has been prepared with maximum care and
attention paid to the content shown. Nonetheless, Climaveneta
waives all liability deriving from the use of such document.
Read this document carefully.
All work must be performed, components selected and materials used professionally and in complete accordance with the
legislation in force in material in the country concerned, and
considering the operating conditions and intended uses of the
system, by qualified personnel.
The data contained in this publication may be changed without
prior notice.
A_LIFE2_0102_1004_201306_EN
a-LIFE2
1. RANGE
WITh cABINET ModEL
a-LIFE2 dLMV/dLMo
version with cabinet, low air intake
a-LIFE2 dFMV/dFMo
version with cabinet, front air intake
100 mm
100 mm
BUILT-IN ModEL
a-LIFE2 dLIo/dLIV
built-in version, low air intake
a-LIFE2 dFIV/dFIo
built-in version, front air intake
100 mm
100 mm
A_LIFE2_0102_1004_201306_EN
a-LIFE2
2. GENERAL dEScRIPTIoN
Fan Coil is a terminal unit for air conditioning during summer
(cooling) and winter (heating).
a-LiFE2 is provided with centrifugal fan, double intake and forward blades, powered by auto-trasformer with 6 speeds of
which 3 are factory-set. other speeds may be requested on the
order by the customer.
a-LIFE2 dLMV
version with cabinet, low air intake, vertical installation
a-LIFE2 dLMo
version with cabinet, low air intake, horizontal installation
a-LIFE2 dFMV
version with cabinet, front air intake, vertical installation
a-LIFE2 dFMo
version with cabinet, front air intake, horizontal installation
a-LIFE2 dLIV
built-in version, low air intake, vertical installation
a-LIFE2 dLIo
built-in version, low air intake, horizontal installation
a-LIFE2 dFIV
built-in version, front air intake, vertical installation
a-LIFE2 dFIo
built-in version, front air intake, horizontal installation
1
2
3
4
5
6
7
8
9
10
11
Casing made from galvanised and coated sheet metal with ABs front intake grill on versions DFMo/DFMV (1), and without grill on versions
DLMo/DLMV (1)
Load-bearing structure made from thick galvanised sheet metal, with holes for wall/ceiling mounting + thermal insulation and soundproofing
on the inside (class M1)
Centrifugal fan with double-sided intake
Electric motor coupled directly to the fan
heat exchanger coil (1 coil for 2-pipe units; 2 coils for 4-pipe units)
Coil water connections
Manual air vent valve
Manual water drain valve
Condensate collection pan with drains + thermal insulation
Condensate drain
Air filter (filtration grade G2)
A_LIFE2_0102_1004_201306_EN
a-LIFE2
2. GENERAL dEScRIPTIoN
LiFE2 DLMV
version with cabinet, low air
intake, vertical installation
LiFE2 DLMo
version with cabinet, low air
intake, horizontal installation
LiFE2 DFMV
version with cabinet, front air
intake, vertical installation
LiFE2 DFMo
version with cabinet, front air
intake, horizontal installation
LiFE2 DLiV
built-in version, low air intake,
vertical installation
LiFE2 DLio
built-in version, low air intake,
horizontal installation
LiFE2 DFiV
built-in version, front air intake,
vertical installation
LiFE2 DFio
built-in version, front air intake,
horizontal installation
dimensions
Built-in
version
dLIV
0102-0104
dLIV
0202-0204
dLIV
0302-0304
dLIV
0402-0404
dLIV
0502-0504
dLIV
0602-0604
dLIV
0702-0704
dLIV
0802-0804
dLIV
0902-0904
dLIV
1002-1004
L (mm)
h (mm)
s (mm)
450
450
215
450
450
215
650
450
215
650
450
215
850
450
215
850
450
215
1050
450
215
1050
450
215
1250
450
215
1250
450
215
Built-in
version
dLIo
0102-0104
dLIo
0202-0204
dLIo
0302-0304
dLIo
0402-0404
dLIo
0502-0504
dLIo
0602-0604
dLIo
0702-0704
dLIo
0802-0804
dLIo
0902-0904
dLIo
1002-1004
L (mm)
h (mm)
s (mm)
545
450
215
545
450
215
745
450
215
745
450
215
945
450
215
945
450
215
1145
450
215
1145
450
215
1345
450
215
1345
450
215
With cabinet
version
dLMV
0102-0104
dLMV
0202-0204
dLMV
0302-0304
dLMV
0402-0404
dLMV
0502-0504
dLMV
0602-0604
dLMV
0702-0704
dLMV
0802-0804
dLMV
0902-0904
dLMV
1002-1004
L (mm)
h (mm)
s (mm)
922
499
233
922
499
233
1112
499
233
1112
499
233
1302
499
233
1302
499
233
1492
499
233
1492
499
233
1682
499
233
1682
499
233
With cabinet
version
dLMo
0102-0104
dLMo
0202-0204
dLMo
0302-0304
dLMo
0402-0404
dLMo
0502-0504
dLMo
0602-0604
dLMo
0702-0704
dLMo
0802-0804
dLMo
0902-0904
dLMo
1002-1004
L (mm)
h (mm)
s (mm)
922
499
233
922
499
233
1112
499
233
1112
499
233
1302
499
233
1302
499
233
1492
499
233
1492
499
233
1682
499
233
1682
499
233
A_LIFE2_0102_1004_201306_EN
a-LIFE2
3. AccESSoRIES coMPATIBILITY
a-LIFE2
description
dLIo
dFIV
dLIV
ELECTRiCAL hEATER
TERMiNAL MAMUT iP20
A_LIFE2_0102_1004_201306_EN
a-LIFE2
3. AccESSoRIES coMPATIBILITY
a-LIFE2
description
dLIo
dFIV
dLIV
A_LIFE2_0102_1004_201306_EN
a-LIFE2
4. UNIT dEScRIPTIoN
a-LIFE2 dLMV, dLMo
covering cabinet
Comprising components made from ABs for the sides and
outlet grills (adjustable by 180) and thick coated sheet metal
for the front panel.
Protective flap for controls in ABs with tamperproof fixing screw
in conformity with directive EN iso 60335-2-40 in relation to
amendment A1 concerning the automatic closure of the flap and
protection of electrical controls against spillage of water.
Quick-fitting controls fixing bracket.
covering cabinet
Comprising components made from ABs for the sides and
outlet grills (adjustable by 180) and thick coated sheet metal
for the front panel.
Protective flap for controls in ABs with tamperproof fixing screw
in conformity with directive EN iso 60335-2-40 in relation to
amendment A1 concerning the automatic closure of the flap and
protection of electrical controls against spillage of water.
Quick-fitting controls fixing bracket
Bearing structure
Galvanised steel frame with high rust resistance.
insulated with self-extinuishing Class 1heat insulating panels.
Unit fitted with condensate collection pan made from insulated
galvanised sheet metal for vertical and horizontal installation.
Terminal block for power and control connections with screw
terminals for remote controls.
Bearing structure
Galvanised steel frame with high rust resistance.
insulated with self-extinuishing Class 1heat insulating panels.
Unit fitted with condensate collection pan made from insulated
galvanised sheet metal for vertical and horizontal installation.
Terminal block for power and control connections with screw
terminals for remote controls.
heat exchange
Coil with corrugated aluminium fins and copper pipes, 100%
tested with dried air.
The water fittings are provided with anti-torsion lock with air
vent and water drainage.
All units are delivered with left-hand water connections, easily
convertible into right-hand by simply turning the coil.
heat exchange
Coil with corrugated aluminium fins and copper pipes, 100%
tested with dried air.
The water fittings are provided with anti-torsion lock with air
vent and water drainage.
All units are delivered with left-hand water connections, easily
convertible into right-hand by simply turning the coil.
Fan motor
Double intake centrifugal fans, statically and dinamically balanced and coupled directly to the electric motor.
Powered by auto-trasformer with 6 speeds of which 3 are factory-set.
Fan motor
Double intake centrifugal fans, statically and dinamically balanced and coupled directly to the electric motor.
Powered by auto-trasformer with 6 speeds of which 3 are factory-set.
Air filter
Made of metal frame and hosting the filtering material, classification G2.
Comprising components made from ABs for the sides and
outlet grills (adjustable by 180) and thick coated sheet metal
for the front panel.
Air filter
Made of metal frame and hosting the filtering material, classification G2.
Easily removable intake grille/filter by the turn screws.
A_LIFE2_0102_1004_201306_EN
a-LIFE2
4. UNIT dEScRIPTIoN
a-LIFE2 dLIo, dLIV
Bearing structure
Galvanised steel frame with high rust resistance.
insulated with self-extinuishing Class 1heat insulating panels.
Unit fitted with condensate collection pan made from insulated
galvanised sheet metal for horizontal and vertical installation.
Double terminal block for power and control connections with
quick connector for plug-in controls. Wall mounted controls are
fixed by screws.
Bearing structure
Galvanised steel frame with high rust resistance.
insulated with self-extinuishing Class 1heat insulating panels.
Unit fitted with condensate collection pan made from insulated
galvanised sheet metal per the horizontal and vertical installation.
Double terminal block for power and control connections with
quick connector for plug-in controls. Wall mounted controls are
fixed by screws.
heat exchange
Coil with corrugated aluminium fins and copper pipes, 100%
tested with dried air.
The water fittings are provided with anti-torsion lock with air
vent and water drainage.
All units are delivered with left-hand water connections, easily
convertible into right-hand by simply turning the coil.
heat exchange
Coil with corrugated aluminium fins and copper pipes, 100%
tested with dried air.
The water fittings are provided with anti-torsion lock with air
vent and water drainage.
All units are delivered with left-hand water connections, easily
convertible into right-hand by simply turning the coil.
Fan motor
Double intake centrifugal fans, statically and dinamically balanced and coupled directly to the electric motor.
Powered by auto-trasformer with 6 speeds of which 3 are factory-set.
Fan motor
Double intake centrifugal fans, statically and dinamically balanced and coupled directly to the electric motor.
Powered by auto-trasformer with 6 speeds of which 3 are factory-set.
Air filter
Made of metal frame and hosting the filtering material, classification G2.
Filter removal is completely safe, and is simplified by turning the
guides at the side to release the filter.
Air filter
Made of metal frame and hosting the filtering material, classification G2.
The filter removal requires a tool as safety measure (according
with anti-tamper regulation).
5. oPERATING LIMITS
Maximum water inlet temp.
Maximum working pressure:
80C
15 bar
0C
45C
21
23
25
27
29
31
15
17
19
21
23
FAcToRY-SET SPEEd
a-LiFE2 is provided with centrifugal fan, powered by auto-trasformer with 6 speeds of which 3 (speed wired standard 2-3-5) are factoryset by Climaveneta. other speeds may be selected on request in the order.
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
a-LIFE2 / DLIO-DFIO
ELECTRICAL DATA
Power supply
Max absorbd power
2 PIPES SYSTEM CONFIGURATION
MAX SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MED SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MIN SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
SIZE AND WEIGHT
A
B
H
Operating weight
0102
0202
0302
0402
0502
0602
0702
0802
0902
1002
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
W
55
55
85
85
75
75
145
145
175
175
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
300
1,50
1,24
0,258
9,0
2,17
0,258
7,6
39
48
360
2,00
1,59
0,344
12,7
2,82
0,345
10,9
45
54
520
2,85
2,22
0,491
30,8
3,86
0,489
26,0
42
51
590
3,40
2,61
0,585
36,1
4,40
0,584
34,5
47
56
660
3,80
2,95
0,654
12,6
5,17
0,654
10,7
45
54
815
4,40
3,52
0,757
17,2
6,06
0,758
14,6
50
59
890
5,15
3,99
0,887
24,2
6,94
0,878
20,3
47
56
980
5,70
4,38
0,981
26,9
7,74
0,979
23,3
50
59
1140
6,15
4,66
1,059
32,9
8,09
1,060
29,1
48
57
1310
7,50
5,81
1,291
46,8
10,1
1,288
40,9
55
64
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
210
1,16
0,90
0,200
5,4
1,62
0,200
4,7
31
40
290
1,74
1,31
0,300
9,6
2,32
0,300
8,3
39
48
410
2,33
1,77
0,401
20,5
3,09
0,400
17,7
37
46
500
2,85
2,22
0,491
28,0
3,84
0,487
24,9
42
51
560
3,08
2,43
0,530
8,2
4,18
0,529
7,2
39
48
670
3,75
2,95
0,646
12,4
5,14
0,650
10,9
45
54
780
4,50
3,49
0,775
18,5
6,15
0,779
16,2
44
53
910
5,06
3,99
0,871
21,2
6,92
0,875
18,8
47
56
1010
5,41
4,16
0,931
25,5
7,16
0,927
22,8
45
54
1180
6,62
5,16
1,140
36,5
8,89
1,138
32,5
51
60
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
180
1,00
0,78
0,172
4,0
1,40
0,173
3,5
28
37
270
1,49
1,18
0,257
7,0
2,08
0,257
6,2
37
46
350
2,07
1,59
0,356
16,2
2,80
0,355
14,1
36
45
380
2,31
1,75
0,398
20,7
3,07
0,398
17,3
37
46
500
2,85
2,22
0,491
7,0
3,82
0,489
6,2
37
46
550
3,02
2,39
0,520
8,0
4,15
0,519
7,1
39
48
640
4,06
3,00
0,699
15,0
5,42
0,701
13,3
41
50
760
4,50
3,44
0,775
16,8
6,12
0,775
15,0
44
53
790
4,71
3,59
0,811
19,4
6,29
0,814
17,9
41
50
920
5,40
4,14
0,930
24,3
7,13
0,923
22,1
45
54
(5)
(5)
(5)
(5)
mm
mm
mm
kg
545
215
450
11
545
215
450
12
745
215
450
14
745
215
450
15
945
215
450
20
945
215
450
21
1145
215
450
23
1145
215
450
25
1345
215
450
27
1345
215
450
29
Notes:
1 Room temperature 27C d.b./19C w.b.; Chilled water (in/out) 7/12C
2 Room temperature 20C d.b.; Hot water (in/out) 50/* C (with identical flow note1)
3 Sound pressure in semianechoic room at 1 (m.) from fan front and 1 (m.) from the ground
4 Sound power on the basis of measurements made in compliance with Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
10
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
a-LIFE2 / DLIV-DFIV
ELECTRICAL DATA
Power supply
Max absorbd power
2 PIPES SYSTEM CONFIGURATION
MAX SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MED SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MIN SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
SIZE AND WEIGHT
A
B
H
Operating weight
0102
0202
0302
0402
0502
0602
0702
0802
0902
1002
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
W
55
55
85
85
75
75
145
145
175
175
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
300
1,50
1,24
0,258
9,0
2,17
0,258
7,6
39
48
360
2,00
1,59
0,344
12,7
2,82
0,345
10,9
45
54
520
2,85
2,22
0,491
30,8
3,86
0,489
26,0
42
51
590
3,40
2,61
0,585
36,1
4,40
0,584
34,5
47
56
660
3,80
2,95
0,654
12,6
5,17
0,654
10,7
45
54
815
4,40
3,52
0,757
17,2
6,06
0,758
14,6
50
59
890
5,15
3,99
0,887
24,2
6,94
0,878
20,3
47
56
980
5,70
4,38
0,981
26,9
7,74
0,979
23,3
50
59
1140
6,15
4,66
1,059
32,9
8,09
1,060
29,1
48
57
1310
7,50
5,81
1,291
46,8
10,1
1,288
40,9
55
64
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
210
1,16
0,90
0,200
5,4
1,62
0,200
4,7
31
40
290
1,74
1,31
0,300
9,6
2,32
0,300
8,3
39
48
410
2,33
1,77
0,401
20,5
3,09
0,400
17,7
37
46
500
2,85
2,22
0,491
28,0
3,84
0,487
24,9
42
51
560
3,08
2,43
0,530
8,2
4,18
0,529
7,2
39
48
670
3,75
2,95
0,646
12,4
5,14
0,650
10,9
45
54
780
4,50
3,49
0,775
18,5
6,15
0,779
16,2
44
53
910
5,06
3,99
0,871
21,2
6,92
0,875
18,8
47
56
1010
5,41
4,16
0,931
25,5
7,16
0,927
22,8
45
54
1180
6,62
5,16
1,140
36,5
8,89
1,138
32,5
51
60
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
180
1,00
0,78
0,172
4,0
1,40
0,173
3,5
28
37
270
1,49
1,18
0,257
7,0
2,08
0,257
6,2
37
46
350
2,07
1,59
0,356
16,2
2,80
0,355
14,1
36
45
380
2,31
1,75
0,398
20,7
3,07
0,398
17,3
37
46
500
2,85
2,22
0,491
7,0
3,82
0,489
6,2
37
46
550
3,02
2,39
0,520
8,0
4,15
0,519
7,1
39
48
640
4,06
3,00
0,699
15,0
5,42
0,701
13,3
41
50
760
4,50
3,44
0,775
16,8
6,12
0,775
15,0
44
53
790
4,71
3,59
0,811
19,4
6,29
0,814
17,9
41
50
920
5,40
4,14
0,930
24,3
7,13
0,923
22,1
45
54
(5)
(5)
(5)
(5)
mm
mm
mm
kg
450
215
450
11
450
215
450
12
650
215
450
14
650
215
450
15
850
215
450
20
850
215
450
21
1050
215
450
23
1050
215
450
25
1250
215
450
27
1250
215
450
29
Notes:
1 Room temperature 27C d.b./19C w.b.; Chilled water (in/out) 7/12C
2 Room temperature 20C d.b.; Hot water (in/out) 50/* C (with identical flow note1)
3 Sound pressure in semianechoic room at 1 (m.) from fan front and 1 (m.) from the ground
4 Sound power on the basis of measurements made in compliance with Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
11
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
a-LIFE2 / DLMV-DFMV / DLMO-DFMO
ELECTRICAL DATA
Power supply
Max absorbd power
2 PIPES SYSTEM CONFIGURATION
MAX SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MED SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MIN SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
SIZE AND WEIGHT
A
B
H
Operating weight
0102
0202
0302
0402
0502
0602
0702
0802
0902
1002
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
W
55
55
85
85
75
75
145
145
175
175
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
300
1,50
1,24
0,258
9,0
2,17
0,258
7,6
39
48
360
2,00
1,59
0,344
12,7
2,82
0,345
10,9
45
54
520
2,85
2,22
0,491
30,8
3,86
0,489
26,0
42
51
590
3,40
2,61
0,585
36,1
4,40
0,584
34,5
47
56
660
3,80
2,95
0,654
12,6
5,17
0,654
10,7
45
54
815
4,40
3,52
0,757
17,2
6,06
0,758
14,6
50
59
890
5,15
3,99
0,887
24,2
6,94
0,878
20,3
47
56
980
5,70
4,38
0,981
26,9
7,74
0,979
23,3
50
59
1140
6,15
4,66
1,059
32,9
8,09
1,060
29,1
48
57
1310
7,50
5,81
1,291
46,8
10,1
1,288
40,9
55
64
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
210
1,16
0,90
0,200
5,4
1,62
0,200
4,7
31
40
290
1,74
1,31
0,300
9,6
2,32
0,300
8,3
39
48
410
2,33
1,77
0,401
20,5
3,09
0,400
17,7
37
46
500
2,85
2,22
0,491
28,0
3,84
0,487
24,9
42
51
560
3,08
2,43
0,530
8,2
4,18
0,529
7,2
39
48
670
3,75
2,95
0,646
12,4
5,14
0,650
10,9
45
54
780
4,50
3,49
0,775
18,5
6,15
0,779
16,2
44
53
910
5,06
3,99
0,871
21,2
6,92
0,875
18,8
47
56
1010
5,41
4,16
0,931
25,5
7,16
0,927
22,8
45
54
1180
6,62
5,16
1,140
36,5
8,89
1,138
32,5
51
60
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
180
1,00
0,78
0,172
4,0
1,40
0,173
3,5
28
37
270
1,49
1,18
0,257
7,0
2,08
0,257
6,2
37
46
350
2,07
1,59
0,356
16,2
2,80
0,355
14,1
36
45
380
2,31
1,75
0,398
20,7
3,07
0,398
17,3
37
46
500
2,85
2,22
0,491
7,0
3,82
0,489
6,2
37
46
550
3,02
2,39
0,520
8,0
4,15
0,519
7,1
39
48
640
4,06
3,00
0,699
15,0
5,42
0,701
13,3
41
50
760
4,50
3,44
0,775
16,8
6,12
0,775
15,0
44
53
790
4,71
3,59
0,811
19,4
6,29
0,814
17,9
41
50
920
5,40
4,14
0,930
24,3
7,13
0,923
22,1
45
54
(5)
(5)
(5)
(5)
mm
mm
mm
kg
922
233
499
16
922
233
499
17
1112
233
499
20
1112
233
499
21
1302
233
499
27
1302
233
499
28
1492
233
499
32
1492
233
499
33
1682
233
499
37
1682
233
499
38
Notes:
1 Room temperature 27C d.b./19C w.b.; Chilled water (in/out) 7/12C
2 Room temperature 20C d.b.; Hot water (in/out) 50/* C (with identical flow note1)
3 Sound pressure in semianechoic room at 1 (m.) from fan front and 1 (m.) from the ground
4 Sound power on the basis of measurements made in compliance with Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
12
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
a-LIFE2 / DLIO-DFIO
ELECTRICAL DATA
Power supply
Max absorbd power
4 PIPES SYSTEM CONFIGURATION
MAX SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MED SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MIN SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
SIZE AND WEIGHT
A
B
H
Operating weight
0104
0204
0304
0404
0504
0604
0704
0804
0904
1004
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
W
55
55
85
85
75
75
145
145
175
175
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
300
1,50
1,24
0,258
9,0
1,25
0,110
6,2
39
48
360
2,00
1,59
0,344
12,7
1,67
0,146
10,7
45
54
520
2,85
2,22
0,491
30,8
2,31
0,203
13,3
42
51
590
3,40
2,61
0,585
36,1
2,76
0,242
18,6
47
56
660
3,80
2,95
0,654
12,6
3,34
0,293
27,0
45
54
815
4,40
3,52
0,757
17,2
3,87
0,339
35,6
50
59
890
5,15
3,99
0,887
24,2
4,36
0,382
37,5
47
56
980
5,70
4,38
0,981
26,9
4,82
0,423
45,2
50
59
1140
6,15
4,66
1,059
32,9
5,18
0,454
54,6
48
57
1310
7,50
5,81
1,291
46,8
6,32
0,554
79,1
55
64
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
210
1,16
0,90
0,200
5,4
0,97
0,085
3,9
31
40
290
1,74
1,31
0,300
9,6
1,45
0,127
8,2
39
48
410
2,33
1,77
0,401
20,5
1,89
0,166
9,1
37
46
500
2,85
2,22
0,491
28,0
2,31
0,203
13,3
42
51
560
3,08
2,43
0,530
8,2
2,71
0,238
18,3
39
48
670
3,75
2,95
0,646
12,4
3,30
0,289
26,4
45
54
780
4,50
3,49
0,775
18,5
3,81
0,334
29,2
44
53
910
5,06
3,99
0,871
21,2
4,28
0,375
36,3
47
56
1010
5,41
4,16
0,931
25,5
4,56
0,400
43,1
45
54
1180
6,62
5,16
1,140
36,5
5,57
0,488
62,5
51
60
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
180
1,00
0,78
0,172
4,0
0,83
0,073
2,9
28
37
270
1,49
1,18
0,257
7,0
1,24
0,109
6,1
37
46
350
2,07
1,59
0,356
16,2
1,68
0,147
7,2
36
45
380
2,31
1,75
0,398
20,7
1,88
0,165
9,0
37
46
500
2,85
2,22
0,491
7,0
2,51
0,220
15,8
37
46
550
3,02
2,39
0,520
8,0
2,65
0,232
17,5
39
48
640
4,06
3,00
0,699
15,0
3,43
0,301
24,0
41
50
760
4,50
3,44
0,775
16,8
3,81
0,334
29,2
44
53
790
4,71
3,59
0,811
19,4
3,97
0,348
33,3
41
50
920
5,40
4,14
0,930
24,3
4,55
0,399
42,9
45
54
(5)
(5)
(5)
(5)
mm
mm
mm
kg
545
215
450
12
545
215
450
12
745
215
450
14
745
215
450
15
945
215
450
21
945
215
450
22
1145
215
450
24
1145
215
450
25
1345
215
450
28
1345
215
450
29
Notes:
1 Room temperature 27C d.b./19C w.b., Chilled water (in/out) 7/12C
2 Room temperature 20C d.b., hot water (in/out) 70/60C
3 Sound pressure in semianechoic room at 1 (m.) from fan front and 1 (m.) from the ground
4 Sound power on the basis of measurements made in compliance with Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
13
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
D/,)('),'/,
(/(&75,&$/'$7$
3RZHUVXSSO\
0D[DEVRUEGSRZHU
3,3(66<67(0&21),*85$7,21
0$;63(('
$LUIORZ
7RWDOFDSDFLW\LQFRROLQJPRGH
6HQVLEOHFDSDFLW\LQFRROLQJPRGH
0D[ZDWHUIORZ
0DGSUHVVXUHGURS
7RWDOFDSDFLW\LQKHDWLQJPRGH
:DWHUIORZLQKHDWLQJ
3UHVVXUHGURSLQKHDWLQJ
1RLVH3UHVVXUH
1RLVH3RZHU
0('63(('
$LUIORZ
7RWDOFDSDFLW\LQFRROLQJPRGH
6HQVLEOHFDSDFLW\LQFRROLQJPRGH
0D[ZDWHUIORZ
0DGSUHVVXUHGURS
7RWDOFDSDFLW\LQKHDWLQJPRGH
:DWHUIORZLQKHDWLQJ
3UHVVXUHGURSLQKHDWLQJ
1RLVH3UHVVXUH
1RLVH3RZHU
0,163(('
$LUIORZ
7RWDOFDSDFLW\LQFRROLQJPRGH
6HQVLEOHFDSDFLW\LQFRROLQJPRGH
0D[ZDWHUIORZ
0DGSUHVVXUHGURS
7RWDOFDSDFLW\LQKHDWLQJPRGH
:DWHUIORZLQKHDWLQJ
3UHVVXUHGURSLQKHDWLQJ
1RLVH3UHVVXUH
1RLVH3RZHU
6,=($1':(,*+7
$
%
+
2SHUDWLQJZHLJKW
9SK+]
:
PK
N:
N:
PK
N3D
N:
PK
N3D
G%$
G%$
PK
N:
N:
PK
N3D
N:
PK
N3D
G%$
G%$
PK
N:
N:
PK
N3D
N:
PK
N3D
G%$
G%$
PP
PP
PP
NJ
1RWHV
5RRPWHPSHUDWXUH&GE&ZE&KLOOHGZDWHULQRXW&
5RRPWHPSHUDWXUH&GEKRWZDWHULQRXW&
6RXQGSUHVVXUHLQVHPLDQHFKRLFURRPDWPIURPIDQIURQWDQGPIURPWKHJURXQG
6RXQGSRZHURQWKHEDVLVRIPHDVXUHPHQWVPDGHLQFRPSOLDQFHZLWK(XURYHQW
8QLWLQVWDQGDUGFRQILJXUDWLRQH[HFXWLRQZLWKRXWRSWLRQDODFFHVVRULHV
14
A_LIFE2_0102_1004_201306_EN
a-LIFE2
6. TEchNIcAL dATA ShEET
a-LIFE2 / DLMV-DFMV / DLMO-DFMO
ELECTRICAL DATA
Power supply
Max absorbd power
4 PIPES SYSTEM CONFIGURATION
MAX SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MED SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
MIN SPEED
Air flow
Total capacity in cooling mode
Sensible capacity in cooling mode
Max water flow
Mad pressure drop
Total capacity in heating mode
Water flow in heating
Pressure drop in heating
Noise Pressure
Noise Power
SIZE AND WEIGHT
A
B
H
Operating weight
0104
0204
0304
0404
0504
0604
0704
0804
0904
1004
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
W
55
55
85
85
75
75
145
145
175
175
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
300
1,50
1,24
0,258
9,0
1,25
0,110
6,2
39
48
360
2,00
1,59
0,344
12,7
1,67
0,146
10,7
45
54
520
2,85
2,22
0,491
30,8
2,31
0,203
13,3
42
51
590
3,40
2,61
0,585
36,1
2,76
0,242
18,6
47
56
660
3,80
2,95
0,654
12,6
3,34
0,293
27,0
45
54
815
4,40
3,52
0,757
17,2
3,87
0,339
35,6
50
59
890
5,15
3,99
0,887
24,2
4,36
0,382
37,5
47
56
980
5,70
4,38
0,981
26,9
4,82
0,423
45,2
50
59
1140
6,15
4,66
1,059
32,9
5,18
0,454
54,6
48
57
1310
7,50
5,81
1,291
46,8
6,32
0,554
79,1
55
64
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
210
1,16
0,90
0,200
5,4
0,97
0,085
3,9
31
40
290
1,74
1,31
0,300
9,6
1,45
0,127
8,2
39
48
410
2,33
1,77
0,401
20,5
1,89
0,166
9,1
37
46
500
2,85
2,22
0,491
28,0
2,31
0,203
13,3
42
51
560
3,08
2,43
0,530
8,2
2,71
0,238
18,3
39
48
670
3,75
2,95
0,646
12,4
3,30
0,289
26,4
45
54
780
4,50
3,49
0,775
18,5
3,81
0,334
29,2
44
53
910
5,06
3,99
0,871
21,2
4,28
0,375
36,3
47
56
1010
5,41
4,16
0,931
25,5
4,56
0,400
43,1
45
54
1180
6,62
5,16
1,140
36,5
5,57
0,488
62,5
51
60
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(4)
m/h
kW
kW
m/h
kPa
kW
m/h
kPa
dB(A)
dB(A)
180
1,00
0,78
0,172
4,0
0,83
0,073
2,9
28
37
270
1,49
1,18
0,257
7,0
1,24
0,109
6,1
37
46
350
2,07
1,59
0,356
16,2
1,68
0,147
7,2
36
45
380
2,31
1,75
0,398
20,7
1,88
0,165
9,0
37
46
500
2,85
2,22
0,491
7,0
2,51
0,220
15,8
37
46
550
3,02
2,39
0,520
8,0
2,65
0,232
17,5
39
48
640
4,06
3,00
0,699
15,0
3,43
0,301
24,0
41
50
760
4,50
3,44
0,775
16,8
3,81
0,334
29,2
44
53
790
4,71
3,59
0,811
19,4
3,97
0,348
33,3
41
50
920
5,40
4,14
0,930
24,3
4,55
0,399
42,9
45
54
(5)
(5)
(5)
(5)
mm
mm
mm
kg
922
233
499
17
922
233
499
18
1112
233
499
21
1112
233
499
22
1302
233
499
29
1302
233
499
30
1492
233
499
33
1492
233
499
35
1682
233
499
38
1682
233
499
40
Notes:
1 Room temperature 27C d.b./19C w.b.; Chilled water (in/out) 7/12C
2 Room temperature 20C d.b.; Hot water (in/out) 70/60 C; Supplementary coil 1-row
3 Sound pressure in semianechoic room at 1 (m.) from fan front and 1 (m.) from the ground
4 Sound power on the basis of measurements made in compliance with Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
15
A_LIFE2_0102_1004_201306_EN
a-LIFE2
7. FAN PERFoRMANcES
a-LiFE2 is designed to assure high pressure also with pressure
drops due to complex ducts. They come with six different fan
speeds. A particular care has been reserved to the configurations
of the three fan speeds cabled by the manufacturer.
The other three fan speeds can be cabled on site.
a-LIFE2 0102-0104
100
The graphs on the following pages show the useful head or working pressures in relation to the air flow and the fan speed.
90
80
70
60
L1
50
40
L2 Velocit massima
Maximum speed
30
L3 Velocit media
Medium Speed
L5
20
L3
L2
L4
L5 Velocit minima
Minimum Speed
10
L6
0
0
50
100
150
200
250
300
350
a-LIFE2 0202-0204
100
90
80
70
60
L1
50
L2 Velocit massima
Maximum speed
40
L5
30
L3
L2
L3 Velocit media
Medium Speed
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
50
100
150
200
250
300
350
400
450
a-LIFE2 0302-0304
100
90
80
70
60
L5
50
L3
L1
L2
40
L2 Velocit massima
Maximum speed
30
L3 Velocit media
Medium Speed
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
50
100
150
200
250
300
350
400
16
A_LIFE2_0102_1004_201306_EN
a-LIFE2
7. FAN PERFoRMANcES
a-LIFE2 0402-0404
100
90
80
70
60
L1
50
40
L5
L3
L2 Velocit massima
Maximum speed
L2
L3 Velocit media
Medium Speed
30
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
50
100
150
200
250
300
350
400
450
500
550
600
650
a-LIFE2 0502-0504
120
110
100
90
80
70
60
L1
50
40
L2 Velocit massima
Maximum speed
30
L3 Velocit media
Medium Speed
L5
L3
L2
L4
20
L5 Velocit minima
Minimum Speed
10
0
L6
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
a-LIFE2 0602-0604
120
110
100
90
80
70
60
L1
50
40
L2 Velocit massima
Maximum speed
30
L3 Velocit media
Medium Speed
L5
20
L3
L2
L4
L5 Velocit minima
Minimum Speed
10
0
L6
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
17
A_LIFE2_0102_1004_201306_EN
a-LIFE2
7. FAN PERFoRMANcES
a-LIFE2 0702-0704
130
120
110
100
90
80
70
60
L1
50
L2 Velocit massima
Maximum speed
40
L5
L3
L3 Velocit media
Medium Speed
L2
30
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
100
200
300
400
500
600
700
800
900
1000
a-LIFE2 0802-0804
130
120
110
100
90
80
70
60
L1
50
L2 Velocit massima
Maximum speed
40
30
L5
L3
L3 Velocit media
Medium Speed
L2
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
100
200
300
400
500
600
700
800
900
1000
1100
18
A_LIFE2_0102_1004_201306_EN
a-LIFE2
7. FAN PERFoRMANcES
a-LIFE2 0902-0904
130
120
110
100
90
80
70
60
L1
50
L2 Velocit massima
Maximum speed
40
L5
30
L3
L3 Velocit media
Medium Speed
L2
L4
20
L5 Velocit minima
Minimum Speed
10
L6
0
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
a-LIFE2 0102-0104
130
120
110
100
90
80
70
60
L1
50
L2 Velocit massima
Maximum speed
40
L3 Velocit media
Medium Speed
30
L4
20
L5
10
0
L3
L2
L5 Velocit minima
Minimum Speed
L6
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
19
A_LIFE2_0102_1004_201306_EN
a-LIFE2
8. PRESSURE dRoP
100
cooLING
a-LIFE2 01020402 (2 pipes)
MAINcoIL
a-LIFE2 0102
a-LIFE2 0202
a-LIFE2 0302
a-LIFE2 0402
10
1
0,10
1,00
100
MAINcoIL
hEATING
a-LIFE2 0102-0302
a-LIFE2 0202
a-LIFE2 0402
10
1
0,10
1,00
100
AddITIoNAL coIL
hEATING
a-LIFE2 0104-0204
a-LIFE2 0304-0404
10
1
0,10
20
A_LIFE2_0102_1004_201306_EN
1,00
a-LIFE2
8. PRESSURE dRoP
100
cooLING
a-LIFE2 05021002 (2 pipes)
MAINcoIL
a-LIFE2
0502-0602-0702
10
a-LIFE2
0802-0902-1002
1
0,15
1,50
100
MAINcoIL
hEATING
a-LIFE2
0502-0602-0702
10
a-LIFE2
0802-0902-1002
1
0,15
1,50
100
AddITIoNAL coIL
hEATING
a-LIFE2 0504-0604
a-LIFE2 0704-0804
a-LIFE2 0904-1004
10
1
0,10
21
A_LIFE2_0102_1004_201306_EN
1,00
a-LIFE2
9. coRREcTIoN FAcToRS IN cooLING oPERATIoN WITh GLYcoL WATER
GLYcoL WATER AT 10%
1,2
Perdite di carico
Pressure drop
1,1
Resa
Capacity
Portata
Water flow
1,0
0,9
0,8
10
11
12
13
14
15
16
17
1,2
Perdite di carico
Pressure drop
1,1
Resa
Capacity
1,0
Portata
Water flow
0,9
0,8
0,7
0,6
10
11
12
13
14
15
16
17
Perdite di carico
Pressure drop
Resa
Capacity
Portata
Water flow
10
11
12
13
14
15
22
16
17
18
A_LIFE2_0102_1004_201306_EN
a-LIFE2
10. coRREcTIoN FAcToRS IN hEATING oPERATIoN WITh GLYcoL WATER
GLYcoL WATER AT 10%
1,4
Perdite di carico
Pressure drop
1,3
Resa
Capacity
1,2
Portata
Water flow
1,1
1,0
0,6
0,8
30
40
50
60
70
80
90 C
1,4
1
Perdite di carico
Pressure drop
1,3
Resa
Capacity
1,2
Portata
Water flow
1,1
1,0
0,6
0,8
30
40
50
60
70
80
90 C
1
1,4
Perdite di carico
Pressure drop
1,3
Resa
Capacity
1,2
Portata
Water flow
1,1
1,0
0,6
0,8
30
40
50
60
70
80
23
90 C
A_LIFE2_0102_1004_201306_EN
a-LIFE2
11. SoUNd PRESSURE LEVEL
a-LIFE2
Model
0102-0104 0202-0204 0302-0304 0402-0404 0502-0504 0602-0604 0702-0704 0802-0804 0902-0904 1002-1004
28
37
36
37
37
39
47
44
41
45
dB(A)
31
39
37
42
39
45
44
47
45
51
39
45
42
47
45
50
41
50
48
55
sound pressure levels in semi-anechoic chamber 1 (m) from fan at front and 1 (m) above the floor
a-LIFE2 0102-0104
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
29,1
29,6
36,6
250 hz
29,9
31,2
38,2
500 hz
28,3
30,4
37,6
1 khz
20,3
24,0
32,6
2 khz
14,3
20,2
29,7
4 khz
10,5
12,3
24,7
8 khz
4,7
1,3
14,4
a-LIFE2 0202-0204
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
37,6
38,3
43,3
250 hz
37,7
39,2
44,1
500 hz
37,0
39,1
44,3
1 khz
29,0
32,7
39,3
2 khz
23,0
28,9
36,4
4 khz
19,2
21,0
31,4
8 khz
13,4
10,0
21,1
a-LIFE2 0302-0304
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
38,3
36,3
41,2
250 hz
35,4
38,1
43,0
500 hz
36,3
35,5
39,6
1 khz
30,2
30,1
35,0
2 khz
25,6
28,1
33,3
4 khz
17,6
21,9
28,9
8 khz
10,8
13,1
24,4
a-LIFE2 0402-0404
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
36,6
42,0
46,6
250 hz
39,1
43,8
48,4
500 hz
37,0
41,2
44,6
1 khz
30,9
35,8
39,7
2 khz
26,3
33,8
38,0
4 khz
18,3
27,6
33,6
8 khz
11,5
18,8
29,1
a-LIFE2 0502-0504
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
36,5
37,9
42,6
250 hz
38,5
39,7
44,9
500 hz
37,9
39,3
44,1
1 khz
28,6
32,9
38,2
2 khz
25,3
29,3
35,3
4 khz
20,7
22,0
28,6
8 khz
15,1
12,9
20,0
a-LIFE2 0602-0604
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
38,2
44,8
49,9
250 hz
40,2
45,7
50,2
500 hz
39,6
45,0
49,8
1 khz
30,3
38,6
43,9
2 khz
27,0
35,0
41,0
4 khz
22,4
27,7
34,3
8 khz
16,8
18,6
25,7
a-LIFE2 0702-0704
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
42,7
38,5
37,4
250 hz
47,5
42,8
41,0
500 hz
46,5
42,5
39,3
1 khz
40,3
37,9
35,1
2 khz
37,5
35,8
34,2
4 khz
28,8
30,7
29,5
8 khz
17,2
21,3
22,2
a-LIFE2 0802-0804
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
39,7
41,5
46,4
250 hz
44,5
45,8
50,0
500 hz
43,5
45,5
48,3
1 khz
37,3
40,9
44,1
2 khz
34,5
38,8
43,2
4 khz
25,8
33,7
38,5
8 khz
14,2
24,3
31,2
a-LIFE2 0902-0904
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
34,5
39,3
43,8
250 hz
40,5
42,5
47,6
500 hz
39,9
41,9
45,5
1 khz
35,3
40,9
42,1
2 khz
33,3
37,2
40,7
4 khz
24,8
31,9
37,1
8 khz
15,4
23,4
29,5
a-LIFE2 1002-1004
Minimum speed
dB(A) Medium speed
Maximum speed
125 hz
34,2
40,0
43,5
250 hz
40,2
43,2
47,3
500 hz
39,6
43,5
45,2
1 khz
35,0
39,9
41,8
2 khz
33,0
37,9
40,4
4 khz
24,5
32,6
36,8
8 khz
15,1
24,1
29,2
Model
0102-0104 0202-0204 0302-0304 0402-0404 0502-0504 0602-0604 0702-0704 0802-0804 0902-0904 1002-1004
dB(A)
48
54
51
56
54
59
56
59
57
64
dB(A)
40
48
46
51
48
54
53
56
54
60
dB(A)
37
46
45
46
46
48
50
53
50
54
sound power on the basis of measurements made in compliance with Eurovent 8/2
24
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
on board controls PS
The Ps control is used to regulate the airflow (3 speeds), select the summer/winter mode of operation and switch the fan-coil on/off and
hot start function by minimun thermostat kit.
Function selector
Cooling
heating
off
Fan selector
Maximum fan speed
Medium fan speed
Minimum fan speed
Electrical connections
J2
Acqua - Water
10
9
8
7
YV2
BN
BU
YV1
BN
6
5
4
3
2
L N PE
BU
BU
Com
RD
Max
WH
Med
BN
Min
AUTR
2 1
BT2
3 4 5 6
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso Red
BU
Blu - Blue
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
YV2
Valvola batteria aggiuntiva Secondary coil valve
1 2
L
L
Valvola
Valve
8 BU
7 BN
J2
IG
3 4 5 6
MV
GNYE
230V~50/60Hz
IG
25
Interruttore di protezione (a cura del cliente) - Thermomagnetic switch (by the customer)
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
on board controls MT
The MT control is used to regulate the air (3 speeds), the temperature through electronic thermostat, to select the summer/winter mode
of operation and to switch the fan-coil on/off.
Temperature selector
Adjust the temperature as required by turning the temperature selector
from +14C to 30C.
Led description
Blue Led: indicates fan-coil thermostat call
Function selector
Cooling
heating
off
Fan selector
Maximum fan speed
Medium fan speed
Minimum fan speed
Electrical connections
J2
UNITA 2-TUBI: Eseguire questo collegamento
sempre in caso di una sola valvola.
2-PIPES UNIT: Always carry out this connection
when there is just one valve.
4 5 6
L
1 2 3
J2
Acqua - Water
BT1
BT2
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso Red
BU
Blu - Blue
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT1
Sonda aria Air sensor
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
YV2
Valvola batteria aggiuntiva Secondary coil valve
L
L
BN
Aria - Air
Valvola
Valve
BU
J1
10
9
8
2 1
YV2
BN
BU
YV1
BN
6
5
4
3
2
L N PE
BU
BU
RD
Com
Max
WH
Med
BN
Min
AUTR
IG
4 5 6
MV
GNYE
230V~50/60Hz
IG
26
Interruttore di protezione (a cura del cliente) - Thermomagnetic switch (by the customer)
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
on board controls AT
The AT control is used to regulate the air (3 speeds + auto), the temperature through electronic thermostat, to select the summer/winter/auto mode of operation and to switch the fan-coil on/off.
Temperature selector
Adjust the temperature as required by turning the temperature selector
from +14C to 30C.
Function button
La scelta del modo di funzionamento possibile tramite il pulsante
Mode led
Cooling
heating
off
Automatic setting
Speed button
select the fan speed pushing the
button.
The repeated pressure of fan button determines speed required.
Maximum fan speed
Medium fan speed
Minimum fan speed
Automatic fan speed
Led
Blue LED: heating / Cooling plus regulator call
Blue LED blinking: hot start / Too Cool function active
Blue LED: operation in Cooling mode
Blue LED: operation in heating mode
Blue LED: automatic cooling / heating mode selection
Electrical connections
Kit GATEWAY
GATEWAY
TTL
J5
BUS BTICINO
2 3 4
13
12
SA1
J1
Aria - Air
J2
Acqua - Water
L
L
BUS-ADAPTER
Kit BUS-ADAPTER
AT
TTL
10
TTL
J5
BT2
BU
YV2
BN
BU
YV1
BN
6
5
230V~
4
3
IG
BUS
BT1
5 6 7
2
L N PE
BU
RD
Com
Max
WH
Med
BN
Min
AUTR
AT
TTL
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso - Red
BU
Blu - Blue
BK Nero - Black
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT1
Sonda aria Air sensor
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
Valvola batteria aggiuntiva Secondary coil valve
YV2
MV
GNYE
230V~50/60Hz
IG Interruttore di protezione (a cura del cliente) - Thermomagnetic switch (by the customer)
SA1 Contatto multifunzionale (a cura del cliente) - Multifunctional contact (by the customer)
27
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
PSW wall-mounted control
The PsW control is used to regulate the airflow (3 speeds), select the summer/winter mode of operation and switch the fan-coil on/off
and hot start function by minimun thermostat kit.
Function selector
Cooling
heating
off
Fan selector
Maximum fan speed
Medium fan speed
Minimum fan speed
Electrical connections
J2
9
8
Acqua - Water
10
9
8
7
BU
YV2
BN
BU
YV1
BN
6
5
4
3
2
1
L N PE
BU
RD
Com
Max
WH
Med
BN
Min
AUTR
BT2
5 6 7
L
2 3 4
L
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso Red
BU
Blu - Blue
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
YV2
Valvola batteria aggiuntiva Secondary coil valve
L
L
Valvola
Valve
8 BU
7 BN
IG
5 6 7
L
3 4
MV
GNYE
230V~50/60Hz
IG
28
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
MTW wall-mounted control
The MTW control is used to regulate the air (3 speeds), the temperature through electronic thermostat, to select the summer/winter
mode of operation and to switch the fan-coil on/off.
Temperature selector
Adjust the temperature as required by turning the temperature selector
from +14C to 30C.
Led
Blue Led: indicates fan-coil thermostat call
Function selector
Cooling
heating
off
Fan selector
Maximum fan speed
Medium fan speed
Minimum fan speed
Electrical connections
J2
UNITA 2-TUBI: Eseguire questo collegamento
sempre in caso di una sola valvola.
2-PIPES UNIT: Always carry out this connection
when there is just one valve.
4 5 6
L
1 2 3
Acqua - Water
10
9
8
2 1
BU
YV2
BN
BU
YV1
BN
6
5
4
3
2
L N PE
BT2
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso Red
BU
Blu - Blue
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT1
Sonda aria Air sensor
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
YV2
Valvola batteria aggiuntiva Secondary coil valve
L
L
BN
9
8
Valvola
Valve
BU
BU
RD
Com
Max
WH
Med
BN
Min
AUTR
IG
4 5 6
MV
GNYE
230V~50/60Hz
IG
29
Interruttore di protezione (a cura del cliente) - Thermomagnetic switch (by the customer)
A_LIFE2_0102_1004_201306_EN
a-LIFE2
13. FANcoIL coNTRoLS
ATW wall-mounted control
The ATW control is used to regulate the air (3 speeds + auto), the temperature through electronic thermostat, to select the summer /
winter / auto mode of operation and to switch the fan-coil on / off.
Temperature selector
Adjust the temperature as required by turning the temperature selector
from +14C to 30C.
Function selector
select the mode of operation pushing the
button.
Mode led
Cooling
heating
off
Automatic setting
Speed button
select the fan speed pushing the
button.
The repeated pressure of fan button determines speed required.
Maximum fan speed
Medium fan speed
Minimum fan speed
Automatic fan speed
Led
Blue LED: heating / Cooling plus regulator call
Blue LED blinking: hot start / Too Cool function active
Blue LED: operation in Cooling mode
Blue LED: operation in heating mode
Blue LED: automatic cooling / heating mode selection
Electrical connections
Collegamento con accessorio Resistenza elettrica
230V~50/60Hz
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
Marrone - Brown
BN
RD Rosso - Red
Blu - Blue
BU
BK Nero - Black
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
BT1
Sonda aria Air sensor
BT2
Sonda acqua Water sensor
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
YV2
Valvola batteria aggiuntiva Secondary coil valve
Kit GATEWAY
AT
TTL
2 3 4
10
GATEWAY
TTL
J5
AT
TTL
4
3
2
BUS-ADAPTER
TTL
L N PE
J5
BU
YV2
BN
BU
YV1
BN
BUS BTICINO
Kit BUS-ADAPTER
BT2
5 6 7
L
Safety Thermostats:
TS1automatic reset
TS2manual reset
TS2
TS1
L
L
BU
BU
Termostati Sicurezza:
TS1riamo automatico
TS2riarmo manuale
13
12
SA1
9
Acqua - Water
8
RD
10
BK
IG
11
Resist.el. El.heater
BU
RD
Com
Max
WH
Med
BN
Min
MV
GNYE
230V~50/60Hz
BUS
12
WH
Relay
5 6 7
AUTR
3 4
230V~
30
IG Interruttore di protezione (a cura del cliente) - Thermomagnetic switch (by the customer)
SA1 Contatto multifunzionale (a cura del cliente) - Multifunctional contact (by the customer)
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. ACCESSORIES
LIFE2BOX
Kit composed by formwork, cover panel, frame and manual flap.
All components are in galvanised steel varnished finish. Life2
Box is placed in the wall niche arranging in advance hydraulic
connections. At work finished the fan-coil is positionate inside
the structure.
Main coil 3-way valve unit with by-pass way (4 idraulic connections) 1/2" and 3/4 kit
Kit with copper fittings and electromechanical actuator (oNoff) 230V, PWM, 0-10V and suitable for 2-pipe systems.
This kit may be used to divert the flow of water of the main coil
in the fan coils. The electromechanical actuator is NC.
Hose kit
The hose kit is a manifold coupling for connecting the fan coil to
the main water system.
31
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
LIFE2 BoX
LiFE2 BoX is a wall-mounted accessory that allows users to prepare the fan coil water and electrical connections in advance.
The fan coil is fitted inside the structure when the work has been
completed, thus simplifying the operations to be performed on
site.
min. 240-max.247
Modelli
LIFE2
A (mm)
B (mm)
0102
0104
812
740
0202
0204
812
740
40
103
660
739
70
102
40
40
206
1012
240
32
A_LIFE2_0102_1004_201306_EN
0302
0304
1012
940
0402
0404
1012
940
0502
0504
1212
1140
0602
0604
1212
1140
a-LIFE2
14. AccESSoRIES
VALVE KIT ModULANTING 0-10V - 2 WAYS 1/2 FITTINGS
The water flow to be diverted for fan coil. Main coil or additional
coil 2-ways valve kit allow valve unit 0-10V could be managed
directly with Climaveneta's controls; install hB power board with
control board 0-10V on fan-coil's side.
33
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
MAINcoIL VALVE KIT - 2 WAY - 1/2" FITTINGS
(oN/oFF - PWM)
This valve kit allows the main coil water flow to be diverted for
fan coil with centrifugal fan.
34
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
VALVE KIT ModULANTING 0-10V - 3 WAYS - 1/2 FITTINGS
The water flow to be diverted for fan coil. Main coil or additional
coil 3-ways valve kit allow valve unit 0-10V could be managed
directly with Climaveneta's controls; install hB power board with
control board 0-10V on fan-coil's side.
3 WAYS MAIN coIL KIT VALVE 1/2" + BYPASS 1/2 + ModULANTING AcTUAToR
0-10V
35
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
MAINcoIL VALVE KIT - 3 WAY - 1/2" FITTINGS
(oN/oFF - PWM)
The valve kit allows the main coil water flow to be diverted for
fan coil with centrifugal fan.
36
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
WATERKIT FoR 2-WAYSVALVE 1/2" FITTING
37
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
AIR SUPPLYPLENUM KIT
The plenum kit allows connection to the ductwork.
STRAIGhT PLENUM
1
14 66
1
100
description
straight plenum
self-tapping screws 3.5x9.5
C
a-LIFE2
A (mm)
B (mm)
c (mm)
0102
0104
400
425
437
0202
0204
400
425
437
0302
0304
600
625
637
Qty.
1
4
0402
0404
600
625
637
0502
0504
800
825
837
0602
0604
800
825
837
0702
0704
1000
1025
1037
0802
0804
1000
1025
1037
0902
0904
1200
1225
1237
1002
1004
1200
1225
1237
90 PLENUM
140
description
90 plenum
self-tapping screws 3.5x9.5
a-LIFE2
200
A (mm)
0102
0104
400
0202
0204
400
0302
0304
600
Qty.
1
4
0402
0404
600
0502
0504
800
0602
0604
800
0702
0704
1000
0802
0804
1000
0902
0904
1200
1002
1004
1200
215
description
Round pipes plenum
self-tapping screws 3.5x9.5
a-LIFE2
B
15
A (mm)
B (mm)
N. pipes
38
0102
0104
400
/
1
0202
0204
400
/
1
0302
0304
600
300
2
Qty.
1
4
0402
0404
600
300
2
0502
0504
800
400
2
0602
0604
800
400
2
0702
0704
1000
350
3
A_LIFE2_0102_1004_201306_EN
0802
0804
1000
350
3
0902
0904
1200
300
4
1002
1004
1200
300
4
a-LIFE2
14. AccESSoRIES
STRAIGhT PLENUM:
Made of galvanized steel, it is used to convery the air supply on the concealed units. optional suitable for installation on all concealed
versions without cabinet.
STRAIGhT PLENUM (PM)
H = 450
15
100
15
S = 215
100
Flangia da 15 mm
15 mm flange
140
140
60
15
15
15
15
L
L
15
Flangia da 15 mm
15 mm flange
H = 450
140
100
15
Dimensioni in mm
Dimensions in mm
Model
Dimensions L (mm)
2 pipe system (1 coil)
4 pipe system (2 coil)
LIFE2 100-200
400
LiFE2 102-202
LiFE2 104-204
LIFE2 300-400
600
LiFE2 302-402
LiFE2 304-404
LIFE2 500-600
800
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
1000
LiFE2 702-802
LiFE2 704-804
LIFE2 900-1000
1200
LiFE2 902-1002
LiFE2 904-1004
90 PLENUM:
Made of galvanized steel, it is used to convery the air supply on the concealed units. optional suitable for installation on all concealed
versions without cabinet.
90 PLENUM (PM 90)
50
H = 450
90
15
15
90
200
110
S = 215
200
215
15
15
140
Flangia da 15 mm
15 mm flange
15
15
140
15
15
H = 450
140
Flangia da 15 mm
15 mm flange
Dimensioni in mm
Dimensions in mm
Model
Dimensions L (mm)
2 pipe system (1 coil)
4 pipe system (2 coil)
LIFE2 100-200
400
LiFE2 102-202
LiFE2 104-204
LIFE2 300-400
600
LiFE2 302-402
LiFE2 304-404
39
LIFE2 500-600
800
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
1000
LiFE2 702-802
LiFE2 704-804
A_LIFE2_0102_1004_201306_EN
LIFE2 900-1000
1200
LiFE2 902-1002
LiFE2 904-1004
a-LIFE2
14. AccESSoRIES
RoUNd PIPES PLENUM:
Made of galvanized steel + internal Thermal-acoustic insulation. it is used to convery the air supply on the concealed units. optional suitable
for installation on all concealed versions without cabinet.
RoUNd PIPES PLENUM 160-180-200
L
A/2
A/2
H = 450
15
150
140
200
215
No. x 160-180-200
150
H = 450
215
150
50 45 45
160
180
S = 215
15
Dimensioni in mm
Dimensions in mm
Model
LIFE2 100-200
Dimensions A (mm)
/
Dimensions L (mm)
400
N x d. (mm)
1x
2 pipe system (1 coil)
LiFE2 102-202
4 pipe system (2 coil)
LiFE2 104-204
Spigots (made of plastic material): 160, 180, 200
LIFE2 300-400
300
600
2x
LiFE2 302-402
LiFE2 304-404
40
LIFE2 500-600
400
800
2x
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
350
1000
3x
LiFE2 702-802
LiFE2 704-804
A_LIFE2_0102_1004_201306_EN
LIFE2 900-1000
300
1200
4x
LiFE2 902-1002
LiFE2 904-1004
a-LIFE2
14. AccESSoRIES
PLENUM KIT FoR AIR oUTLET
The plenum kit allows connection to the ductwork.
STRAIGhT PLENUM
1
14 66
1
100
description
Straight plenum
self-tapping screws 3.5x9.5
C
a-LIFE2
A (mm)
B (mm)
B (mm)
0102
0104
400
425
437
0202
0204
400
425
437
0302
0304
600
625
637
Qty.
1
4
0402
0404
600
625
637
0502
0504
800
825
837
0602
0604
800
825
837
0702
0704
1000
1025
1037
0802
0804
1000
1025
1037
0902
0904
1200
1225
1237
1002
1004
1200
1225
1237
90 PLENUM
140
description
90 plenum
self-tapping screws 3.5x9.5
a-LIFE2
200
A (mm)
0102
0104
400
0202
0204
400
0302
0304
600
Qty.
1
4
0402
0404
600
0502
0504
800
0602
0604
800
0702
0704
1000
0802
0804
1000
0902
0904
1200
1002
1004
1200
215
description
Round pipes plenum
self-tapping screws 3.5x9.5
a-LIFE2
15
B
0
A (mm)
B (mm)
N. pipes
41
0102
0104
400
/
1
0202
0204
400
/
1
0302
0304
600
300
2
Qty.
1
4
0402
0404
600
300
2
0502
0504
800
400
2
0602
0604
800
400
2
0702
0704
1000
350
3
A_LIFE2_0102_1004_201306_EN
0802
0804
1000
350
3
0902
0904
1200
300
4
1002
1004
1200
300
4
a-LIFE2
14. AccESSoRIES
STRAIGhT PLENUM:
Made of galvanized steel, it is used to convery the air intake on the concealed units. optional suitable for installation on all concealed
versions without cabinet.
STRAIGhT PLENUM (PM)
100
15
140
140
37,5
15
H = 450
S = 215
37,5
15
15
15
15
100
H = 450
140
Flangia da 15 mm
15 mm flange
100
Flangia da 15 mm
15 mm flange
15
Dimensioni in mm
Dimensions in mm
15
Model
Dimensions L (mm)
2 pipe system (1 coil)
4 pipe system (2 coil)
LIFE2 100-200
400
LiFE2 102-202
LiFE2 104-204
LIFE2 300-400
600
LiFE2 302-402
LiFE2 304-404
LIFE2 500-600
800
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
1000
LiFE2 702-802
LiFE2 704-804
LIFE2 900-1000
1200
LiFE2 902-1002
LiFE2 904-1004
90 PLENUM:
Made of galvanized steel, it is used to convery the air intake on the concealed units. optional suitable for installation on all concealed
versions without cabinet.
90 PLENUM (PM 90)
L
90 50
15
H = 450
S = 215
215
110
200
90
15
15
15
140
Flangia da 15 mm
15 mm flange
H = 450
200
15
15
Model
Dimensions L (mm)
2 pipe system (1 coil)
4 pipe system (2 coil)
15
15
140
140
Dimensioni in mm
Dimensions in mm
LIFE2 100-200
400
LiFE2 102-202
LiFE2 104-204
Flangia da 15 mm
15 mm flange
LIFE2 300-400
600
LiFE2 302-402
LiFE2 304-404
42
LIFE2 500-600
800
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
1000
LiFE2 702-802
LiFE2 704-804
A_LIFE2_0102_1004_201306_EN
LIFE2 900-1000
1200
LiFE2 902-1002
LiFE2 904-1004
a-LIFE2
14. AccESSoRIES
RoUNd PIPES PLENUM:
Made of galvanized steel + internal Thermal-acoustic insulation. it is used to convery the air intake on the concealed units. optional suitable
for installation on all concealed versions without cabinet.
RoUNd PIPES PLENUM 160-180-200
L
A/2
A/2
140
15
150
H = 450
S = 215
160
180
215
200
15
150
H = 450
215
Filtro aria
Air filter
45 45 50
150
No. x 160-180-200
Dimensioni in mm
Dimensions in mm
Model
LIFE2 100-200
Dimensions A (mm)
/
Dimensions L (mm)
400
N x d. (mm)
1x
2 pipe system (1 coil)
LiFE2 102-202
4 pipe system (2 coil)
LiFE2 104-204
Spigots (made of plastic material): 160, 180, 200
LIFE2 300-400
300
600
2x
LiFE2 302-402
LiFE2 304-404
43
LIFE2 500-600
400
800
2x
LiFE2 502-602
LiFE2 504-604
LIFE2 700-800
350
1000
3x
LiFE2 702-802
LiFE2 704-804
A_LIFE2_0102_1004_201306_EN
LIFE2 900-1000
300
1200
4x
LiFE2 902-1002
LiFE2 904-1004
a-LIFE2
14. AccESSoRIES
100
FEET KIT
The feet kit allows the fan coils with housing to be placed on the
ground.
186,5
186,5
44
A_LIFE2_0102_1004_201306_EN
232,7
a-LIFE2
14. AccESSoRIES
SPB INTERFAcE KIT
60 mm
90 mm
71 mm
70
180
130
10
80
GRIGLIA / GRILLE
FILTRO ARIA / AIR FILTER
a-LIFE2
A (mm)
B (mm)
45
0102
0104
400
450
0202
0204
400
450
0302
0304
600
650
0402
0404
600
650
0502
0504
800
850
0602
0604
800
850
A_LIFE2_0102_1004_201306_EN
0702
0704
1000
1050
0802
0804
1000
1050
0902
0904
1200
1250
1002
1004
1200
1250
a-LIFE2
130
45
B
80
180
11
14. AccESSoRIES
a-LIFE2
1002
1004
1200
1250
KIT A Manual fresh air intake damper kit. The kit is used to
adjust the amount of fresh air introduced into the environment.
The amount of fresh air introduced varies from 0 to approx. 30%
of the volume handled by the fan coil.
dAMPER FoR UNITS WITh cASING
KIT A (manual damper)
MOTORE SERRANDA
DAMPER MOTOR
2 X 6MA NUTS FOR
FASTENING ON THE PIN
46
A_LIFE2_0102_1004_201306_EN
a-LIFE2
14. AccESSoRIES
AIR INTAKE GRId FoR WITh cABINET VERSIoN
Kit accessory allows to cover space between feet of LiFE2 fan
coil. Air intake grid for with cabinet is suitable for DLMV version
(with cabinet and bottom air inlet). Air intake grille is painted as
fan coil cabinets colour (RAL 9003) ensuring suitable and
desired aesthetic solution.
100
0902
0904
1682
1326
1002
1004
1692
1326
Safety Thermostats:
TS1 automatic reset
TS2 manual reset
GNYE Giallo/Verde-Yellow/Green
WH Bianco - White
BN
Marrone - Brown
RD Rosso - Red
BU
Blu - Blue
BK Nero - Black
L
Fase (linea 230V~) - Phase (230V~line)
N
Neutro - Neutral
PE
Terra - Earth
Com Comune ventilatore - Common of the fan
Min
Velocit Minima - Min. speed (Low)
Med
Velocit Media - Med. speed (Medium)
Max
Velocit Massima - Max. speed (High)
MV
Motore ventilatore Fan motor
C
Condensatore Capacitor
AUTR Autotrasformatore Autotransformer
ACCESSORI ACCESSORIES
YV1
Valvola batteria principale Main coil valve
Valvola batteria aggiuntiva Secondary coil valve
YV2
A CURA DEL CLIENTE - BY THE CUSTOMER
Comando remoto - Remote control
CR
Interruttore di protezione - Thermomagnetic switch
IG
Potenza - Power
Potenza - Power
N
12
BK
11
N
L
TS1
BU
BU
N
L
Resist.el.
El.heater
WH
10
CR
Relay
10
9
8
7
RD
TS2
BU
YV2
BN
BU
YV1
BN
6
N
IG
N
L
L
L
L
PE
47
5
4
3
2
1
BU
RD
Com
Max
WH
Med
BN
Min
GNYE
A_LIFE2_0102_1004_201306_EN
AUTR
Termostati Sicurezza:
TS1 riamo automatico
TS2 riarmo manuale
230V~50/60Hz
230V~50/60Hz
MV
A_LIFE2_0102_1004_201306_EN
25
15
25
A
B
25
15
450
15
185,8
15,8
217
450
30
120
15
134
261
175,9
120
42
178
155
69
20
336
230
0102
0104
430
400
450
425
Modello
a-LIFE2
A (mm)
B (mm)
c (mm)
d (mm)
120
48
120
15
430
400
450
425
0202
0204
630
600
650
625
0302
0304
630
600
650
625
0402
0404
830
800
850
825
0502
0504
830
800
850
825
0602
0604
1030
1000
1050
1025
0702
0704
1030
1000
1050
1025
0802
0804
33
1230
1200
1250
1225
0902
0904
1230
1200
1250
1225
1002
1004
16
10
a-LIFE2
A_LIFE2_0102_1004_201306_EN
12
204,8
210
33
105
75
25
20
600
630
40
15
450
15
185,8
15,8
134
261
0102
0104
430
400
450
425
545
A (mm)
B (mm)
c (mm)
d (mm)
E (mm)
430
400
450
425
545
0202
0204
630
600
650
625
745
0302
0304
630
600
650
625
745
0402
0404
830
800
850
825
945
830
800
850
825
945
0602
0604
0502
0504
Modello
a-LIFE2
120
42
178
155
69
336
106
30
230
120
49
30
15
0802
0804
1030
1000
1050
1025
1145
0702
0704
1030
1000
1050
1025
1145
33
1230
1200
1250
1225
1345
0902
0904
1230
1200
1250
1225
1345
1002
1004
16
10
a-LIFE2
a-LIFE2
INVERTING ThE WATER coNNEcTIoNS
WARNING! Run the electrical wiring on the opposite side to the final water connections.
Remove the transformer and the terminal block and reposition them on the opposite side.
If the controller is installed on the unit, remove the controller complete with fastening bracket.
If the room temperature probe cable is not long enough, move the room temperature probe to the opposite side.
INSTRUcTIoNS To MoVE ThE MAIN coIL FRoM LEFT To RIGhT oN VERTIcAL FAN coILS
1
8
G
14
13
7
14
10
15
F
11
12
A.
B.
50
A_LIFE2_0102_1004_201306_EN
a-LIFE2
INVERTING ThE WATER coNNEcTIoNS
WARNING! Run the electrical wiring on the opposite side to the final water connections.
Remove the transformer and the terminal block and reposition them on the opposite side.
If the controller is installed on the unit, remove the controller complete with fastening bracket.
If the room temperature probe cable is not long enough, move the room temperature probe to the opposite side.
INSTRUcTIoNS To MoVE ThE MAIN coIL FRoM LEFT To RIGhT oN hoRIZoNTAL FAN coILS:
96
,5
11
2
9
12
13
12
4
C
10
5
A.
B.
51
A_LIFE2_0102_1004_201306_EN
a-LIFE2
15. dIMENSIoNAL dATA (WIThcABINET VERSIoN)
mm
mm
0102-0104
922
566
0202-0204
922
566
0302-0304
1112
756
0402-0404
1112
756
0502-0504
1302
946
0602-0604
1302
946
0702-0704
1492
1136
0802-0804
1492
1136
0902-0904
1682
1326
547
599
499
100
a-LIFE2 dLMV
A
B
186,5
233
A
1112
52
A_LIFE2_0102_1004_201306_EN
1002-1004
1682
1326
a-LIFE2
16. ELECTRICAL CONNECTIONS
The fan coil comes fully wired and only requires:
- Connecting to the mains electricity supply and to any room
control.
It is also recommended to check that:
- The characteristics of the mains electricity supply are suitable
for the input indicated in the table below, which (with maximum values) should serve for sizing both the circuit breakers
and the power cables (any other appliances working in parallel should also be taken into consideration).
- The supply voltage corresponds to the rated value +/- 10%.
Power supply
0102-0104
230 ~ 50
45
0,20
0202-0204
230 ~ 50
45
0,20
0302-0304
230 ~ 50
60
0,30
0402-0404
230 ~ 50
60
0,30
0502-0504
230 ~ 50
63
0,30
0602-0604
230 ~ 50
63
0,30
0702-0704
230 ~ 50
130
0,60
0802-0804
230 ~ 50
130
0,60
0902-0904
230 ~ 50
160
0,73
1002-1004
230 ~ 50
160
0,73
Power supply
0102-0104
230 ~ 50
1045
4,6
0202-0204
230 ~ 50
1045
4,6
0302-0304
230 ~ 50
1560
6,9
0402-0404
230 ~ 50
1560
6,9
0502-0504
230 ~ 50
2063
9,1
0602-0604
230 ~ 50
2063
9,1
0702-0704
230 ~ 50
3130
13,7
0802-0804
230 ~ 50
3130
13,7
0902-0904
230 ~ 50
3160
13,9
1002-1004
230 ~ 50
3160
13,9
Power supply
0102-0104
230 ~ 50
745
3,3
0202-0204
230 ~ 50
745
3,3
0302-0304
230 ~ 50
1060
4,7
0402-0404
230 ~ 50
1060
4,7
0502-0504
230 ~ 50
1563
6,9
0602-0604
230 ~ 50
1563
6,9
0702-0704
230 ~ 50
2130
9,4
0802-0804
230 ~ 50
2130
9,4
0902-0904
230 ~ 50
2160
9,5
1002-1004
230 ~ 50
2160
9,5
53
A_LIFE2_0102_1004_201306_EN
Climaveneta S.p.A.
Climaveneta France
3, Village dEntreprises
ZA de la Couronne des Prs
Avenue de la Mauldre
78680 Epne
France
Tel +33 (0)1 30 95 19 19
Fax +33 (0)1 30 95 18 18
[email protected]
www.climaveneta.fr
Climaveneta UK LTD.
Highlands Road,
Shirley Solihull
West Midlands B90 4NL
Tel: +44 (0)871 663 0664
Fax: +44 (0)871 663 1664
Freephone: 0800 801 819
[email protected]
www.climaveneta.co.uk
www.climaveneta.com