ACI318 MN
ACI318 MN
ACI318 MN
Eq. (18-3)
= 270
1 -
0.28
0.80
0.00348
270
5
= 252 ksi
where
p
= 0.28 for
f
f
py
pu
= 0.90 for low-relaxation strand
1
= 0.80 for f
c
= 5000 psi 10.2.7.3
p
=
A
bd
ps
p
=
6 0.153
12 22
= 0.00348
24-25
Code
Example 24.3 (contd) Calculations and Discussion Reference
2. Calculate nominal moment strength from Eqs. (9) and (10) of Part 24
Compute the depth of the compression block:
a =
A f
bf
ps ps
c
0 85 .
=
0.918 252
0.85 12 5
= 4.54 in. Eq. (10)
M
n
= A
ps
f
ps
d
a
p
-
2
Eq. (9)
M
n
= 0.918 252 22
4 54
2
-
.
/ 22
c/d
p
= 0.258 < 0.375 R9.3.2.2
Tension controlled = 0.9
24-3
Duct A conduit (plain or corrugated) to accommodate prestressing steel for post-tensioned installation.
Requirements for post-tensioning ducts are given in 18.17.
Sheathing A material encasing prestressing steel to prevent bonding of the prestressing steel with the sur-
rounding concrete, to provide corrosion protection, and to contain the corrosion inhibiting coating.
270
250
230
210
190
170
150
0 0.005 0.010 0.015 0.020 0.025 0.030
E
ps
= 28,500 ksi
Per ASTM A 416
minimum yield strength at
1% elongation for 270 ksi
= 243 ksi
270 ksi
Strain,
ps
(in./in.)
Stress
f
ps
(ksi)
The above curve can be approximated by the following equations:
ps
0.007
0.04
(ksi)
ps
0.0086: f
ps
= 28,500
ps
(ksi)
ps
> 0.0086: f
ps
= 270
x
Figure 24-1 Stress-Strain Curve for Grade 270, Low Relaxation Strand
(24.1)
18.2 GENERAL
The code specifies strength and serviceability requirements for all concrete members, prestressed or nonprestressed.
This section requires that, for prestressed members, both strength and behavior at service conditions must be
checked. All load stages that may be critical during the life of the structure, beginning with the transfer of the
prestressing force to the member and including handling and transportation, must be considered.
This section also calls attention to several structural issues specific to prestressed concrete structures that must
be considered in design:
18.2.3...Stress concentrations. See 18.13 for requirements for post-tensioned anchorages.
24-26
Example 24.4Flexural Strength of Prestressed Member Based on Strain
Compatibility
The rectangular beam section shown below is reinforced with a combination of prestressed and nonprestressed
strands. Calculate the nominal moment strength using the strain compatibility (moment-curvature) method.
f
c
= 5000 psi
f
pu
= 270,000 psi (low-relaxation strand; f
py
= 0.9f
pu
)
E
ps
= 28,500 ksi
jacking stress = 0.74f
pu
losses = 31.7 ksi (calculated by method of Ref. 24.4. See 18.6 Loss of Prestress for procedure.)
Code
Calculations and Discussion Reference
1. Calculate effective strain in prestressing steel.
= (0.74f
pu
- losses)/E
ps
= (0.74 270 - 31.7)/28,500 = 0.0059
2. Draw strain diagram at nominal moment strength, defined by the maximum concrete 18.3.1
compressive strain of 0.003 and an assumed distance to the neutral axis, c. For f
c
=
5000,
1
= 0.80.
12"
Prest.
Nonprest.
6-1/2"
1'-8"
2'-0"
2"
0.0059
Strains Stresses
A
Trials
0.003
c
2
C
a
2
.85
a = .80c
M
n
T
1
= A
s1
f
1
T
2
= A
s2
f
2
3. Obtain equilibrium of horizontal forces.
The strain line drawn above from point 0 must be located to obtain equilibrium of
horizontal forces:
C = T
1
+ T
2
To compute T
1
and T
2
, strains
1
and
2
are used with the stress-strain relation for the
strand to determine the corresponding stresses f
1
and f
2
. Equilibrium is obtained using
the following iterative procedure:
24-27
Code
Example 24.4 (contd) Calculations and Discussion Reference
a. assume c (location of neutral axis)
b. compute
1
and
2
c. obtain f
1
and f
2
from the equations in Fig. 24-1.
d. compute a =
1
c
e. compute C = 0.85ab
f. compute T
1
and T
2
g. check equilibrium using C = T
1
+ T
2
h. if C < T
1
+ T
2
, increase c, or vice versa and return to step b of this procedure.
Repeat until satisfactory convergence is achieved.
Estimate a neutral axis location for first trial. Estimate stressed strand at 260 ksi, unstressed
strand at 200 ksi.
T = A
ps
f
s
= 0.306 (200) + 0.612 (260) = 220 kips = C
a = C/(0.85 b) = 220/(0.85 5 12) = 4.32 in.
c = a/
1
= 4.32/0.80 = 5.4 in. Use c = 5.4 in. for first try
The following table summarizes the iterations required to solve this problem:
Trial
No.
c
in.
1
2
f
1
ksi
f
2
ksi
a
in.
C
kips
T
1
kips
T
2
kips
T
1
+ T
2
kips
1 5.4 0.0081 0.0151 231 265 4.32 220 71 162 233
2 O.K. 5.6 0.0077 0.0147 220 265 4.48 228.5 67 162 229
4. Calculate nominal moment strength.
Using C = 228.5 kips, T
1
= 67 kips and T
2
= 162 kips, the nominal moment strength can
be calculated as follows by taking moments about T
2
:
M
n
= [((d
2
- a/2) C) - ((d
2
- d
1
) T
1
)]/12
= [(22 - (4.48/2)) 228.5 - (22 - 20) 67)]/12 = 365 ft-kips