A500 Vs A513
A500 Vs A513
A500 Vs A513
Chemical
Composition
CMax
Mn Max
P Max
S Max
ASTM A513-08a
Composition, %
Heat
Product
Analysis Analysis
0.26
0.30
1.35
1.40
0.035
0.045
0.035
0.045
Grade
Designation
MT 1010
MT 1015
MT X 1015
MT 1020
MT X 1020
C
0.02-0.15
0.10-0.20
0.10-0.20
0.15-0.25
0.15-0.25
S MAX
0.035
0.035
0.035
0.035
0.035
Tensile
Requirements
Shaped structual
Grade A
Tubing
TS(Mpa)MIN
45000
YS(Mpa)MIN
39000
25
EL)MIN(*)
(*) Specified wall thickness(t) is
lighter than 0.120 in,
Elongation(%) = 56t + 17.5
Tolerance
Outside
Dimensions
Convexity and
Concavity
Wall Thickness
Length
Largest Dimension(Inches)*
Tolerance(inches)**
2-1/2 and under
0.020
Over 2-1/2 to 3-1/2, incl
0.025
Over 3-1/2 to 5-1/2, incl
0.030
* Measured at least 2" from cut end of tubing
Largest Dimension(Inches)*
Tolerance(inches)
0.004
3/16 to 5/8, incl
Over 5/8 to 1-1/8, incl
0.005
Over 1-1/8 to 1-1/2, incl
0.006
Over 1-1/2 to 2, incl
0.008
Over 2 to 3, incl
0.010
Over 3 to 4, incl
0.020
* Measured at least 2" from cut end of tubing
Largest Dimension(Inches)*
2-1/2 and under
Over 2-1/2 to 4, incl
Tolerance(inches)
0.010
0.015
Tolerance(Inches)
1/16
3/32
1/8
3/16
Squareness of
Sides
2Max
(2x2x0.120 0.070in)
Radius
of Corners
Max 3t
Twist
Largest Dimension(Inches)
1-1/2 and under
Over 1-1/2 to 2-1/2, incl
Over 2-1/2 to 4, incl
Max in 3ft(Inches)
0.050
0.062
0.075
Largest Dimension(Inches)
1/2 and under
Over 1/2 to 1-1/2, incl
Over 1-1/2 to 2-1/2, incl
Over 2-1/2 to 4, incl
Wall thickness
(Inches)
0.047
0.060
0.083
0.095
0.120
Wall thickness
(Inches)
0.047
0.060
0.083
0.095
0.120
Radius
Tolerance
(Inches)
3/64 to 5/64
1/16 to 7/64
5/64 to 1/8
3/32 to 5/32
1/8 to 7/32
Max in 3ft(Inches)
0.032
0.050
0.062
0.075
6.25.2010
Chemical
Composition
Tensile
Requirements
*When Tensile Properties are required, they shall be specified in the purchase order.
Tolerance
Outside Diameter(in)*
Outside
Diameter
5/8,
Over
Over
Over
Over
Wall Thickness
in
0.047
0.060
0.072
0.083
0.095
0.120
Wall Thickness
in
0.060
0.072
0.083
0.095
0.120
Length
Straightness
Ovality
Squareness
of Cut
(Either End)
Flash-In-Tubing
Tolerance(in)
Cold Rolled
0.047 to 0.060
0.047 to 0.120
0.047 to 0.120
0.047 to 0.120
0.047 to 0.120
Hot Rolled (and PO)
0.060 to 0.120
0.060 to 0.120
0.060 to 0.120
0.060 to 0.120
2" from cut end of tubing
incl
5/8 to 1-1/8, incl
1-1/8 to 2, incl
2 to 2-1/2, incl
2-1/2 to 3, incl
Wall
Thickness
Wall Thickness(in)
Colled Rolled
Outside Diameter(in)
5/8 to 7/8 Incl.
Over 7/8 to 1-1/8 Incl.
+
+
0.003
0.006
0.002
0.006
0.005
0.007
0.004
0.007
0.005
0.007
0.004
0.007
0.006
0.007
0.005
0.007
0.006
0.007
0.005
0.007
0.007
0.008
Hot Rolled (and PO)
Outside Diameter(in)
3/4 to 1 Incl.
Over 1 to 1-15/16 Incl.
+
+
0.005
0.009
0.004
0.010
0.005
0.009
0.004
0.010
0.006
0.010
0.005
0.011
0.006
0.010
0.005
0.011
0.006
0.010
0.005
0.011
0.003
0.0035
0.005
0.006
0.008
0.0035
0.005
0.006
0.080
Length of Tube, ft
Under 1
Under 1
0.006
1 to 3, Incl
0.008
Over 3 to 6, Incl
0.010
Over 6 to 9, Incl
0.015
*when Specified for Round Tubing
Tolerance (in)
Outside Diameter, in
Over 2 to 3,
1 to 2, incl
incl
0.008
0.010
0.010
0.015
0.020
0.015
0.020
0.025