Zenith Pumps: B-Series Gear Pumps
Zenith Pumps: B-Series Gear Pumps
Zenith Pumps: B-Series Gear Pumps
Pumps
Installation,
Care and
Maintenance
Zenith
Chemical Duty
Gear Pumps
B-Series
Gear Pumps
2
Zenith
to provide precision
fluid handling solutions for their most
difficult pumping applications. Zenith
.
5
Installation
Pumps should be carefully unpacked
and checked to make sure that the ship-
ment is complete. If any items are miss-
ing or damaged, the freight carrier and
Zenith
pump,
B-Series pumps may be returned to
Zenith
to learn the
manufacturing, gauging, and assembly
techniques involved in producing the
B-Series pump. In addition, Zenith
also
offers a contract service program. Please
contact Zenith
for details.
17
BXB Series
Assembly
Note: Considerable care should be
taken to prevent wedging or jamming of
parts. Never force parts into place. All
parts should drop into place if properly
aligned. During assembly, manually turn
the metering gears to ensure free rotation.
If binding occurs at any time, determine
the cause and correct it immediately. A
small nick, burr, or foreign particle may
cause extensive damage to pump
components.
1) Provide a can of clean oil, preferably
SAE-50 motor oil or mineral oil.
2) Lubricate the dowel and arbor holes
in the Front and Rear Plates. Using
the Driven Gear as a guide, press the
arbor (5) into the Front Side Plate (1).
The thermocouple hole in the arbor
should be facing upwards. Press the
dowels (9) into the rear side plate (3).
3) Place the rear side plate onto a bench
with the dowels and arbor facing up.
4) Lower the gear plate (2) over the
dowels and onto the rear side plate.
Ensure that the correct port location
of the gear and rear plates are
maintained.
5) Gently insert the drive shaft (4), key
(8), and driving gear assembly (6)
into the gear pocket and rear side
plate bearing. Ensure free rotation of
the drive shaft.
6) Carefully insert the driven gear (7)
onto the arbor (5) and lower into the
gear plate. Again, ensure free rotation
of the driving and driven gears.
7) Place the front side plate (1) and arbor
(5) over the end of the drive shaft and
into position over the dowels.
8) Turn the pump onto its side and insert
the binder screws (21).
9) Place the pump into a vice with the
drive shaft facing down. Tighten the
binder screws to 50% of their rated
torque using a crossing pattern. Turn
the drive shaft to ensure free rotation.
If no binding occurs, completely tighten
the binder screws to 100% of their
rated torque. Again, check for free
rotation.
10) Turn the pump over so that the drive
shaft is facing up.
11) Insert new lip seals (31) into the seal
plates (13).
12) Use of a Zenith
Pumps
1710 Airport Road
Monroe, NC 28110
Phone: 704-289-6511 Fax: 704-289-9273
[email protected] www.zenithpumps.com
A Colfax Buisiness Unit
ISO 9001: 2000 Registered