This document summarizes industrial 3-way dual shut-off valves used for refrigeration systems. It describes the materials they are made from, pressure and temperature ratings, and applications. These valves have two inlets and two outlets to allow either side to be closed off individually. They are required in refrigeration systems over 10 cubic feet to safely install or replace relief valves without shutting down the entire system. The document provides specifications for various models including connection sizes, dimensions, and weights.
This document summarizes industrial 3-way dual shut-off valves used for refrigeration systems. It describes the materials they are made from, pressure and temperature ratings, and applications. These valves have two inlets and two outlets to allow either side to be closed off individually. They are required in refrigeration systems over 10 cubic feet to safely install or replace relief valves without shutting down the entire system. The document provides specifications for various models including connection sizes, dimensions, and weights.
This document summarizes industrial 3-way dual shut-off valves used for refrigeration systems. It describes the materials they are made from, pressure and temperature ratings, and applications. These valves have two inlets and two outlets to allow either side to be closed off individually. They are required in refrigeration systems over 10 cubic feet to safely install or replace relief valves without shutting down the entire system. The document provides specifications for various models including connection sizes, dimensions, and weights.
This document summarizes industrial 3-way dual shut-off valves used for refrigeration systems. It describes the materials they are made from, pressure and temperature ratings, and applications. These valves have two inlets and two outlets to allow either side to be closed off individually. They are required in refrigeration systems over 10 cubic feet to safely install or replace relief valves without shutting down the entire system. The document provides specifications for various models including connection sizes, dimensions, and weights.
29 Bodies: 92Series: forged brass; 802series: forged steel; painted Maximumworking pressure: 450 PSI (31.0 Bar) Steel 650 PSI (44.8 Bar) Brass Temperature rating: Steel -20F (-29C) to +300F (+149C) Brass 40F (-40C) to +300F (+149C) Recommended for use with relief valve types 92 series is suitablefor refrigerants and other industrial fluids non-corrosive to steel and brass 802A Series is suitable for refrigerants including ammonia and other industrial fluids non-corrosive to steel Feat ur es: On all vessels 10 ft and larger when relief valves are used as the over pressure protective device, a dual relief valve assembly is required. Three-Way Dual Shut-off Valve inlets are shown at the bottom of the illustration. Tight shut-off can be obtained at either extreme of stem position, closing off either the left or right outlet port. The system should not be run with the valve stem in the center position. A dual relief valve installation consists of one three-way shut-off valve and two relief valves so arranged that both relief valves cannot be shut off from the protected pressure vessel at the same time. This permits safe removal of either relief valve for repair or replacement, while the vessel is protected and under pressure. Each relief valve must have sufficient capacity to provide the necessary discharge flow when used alone. The design of this Three-Way Valve provides full discharge area through the valve regardless of stem position, assuring maximum protection. Furthermore, this design provides for convenient parallel mounting of the two relief valves and fulfills the requirement set forth in the ANSI/ASHRAE 15. No stop valve shall be located between any automatic pres- sure relief device or fusible plug and the part or parts of the system protected thereby, except when the parallel relief de- vices are so arranged that only one can be rendered inopera- tive at a time for test or repair purposes. Two three-way valves, installed in a drier bypass arrangement, permit installation or removal of service drier without air, dirt, or moisture entering line. Type Catalog Number Conn. Size Dimensions in Inches A B C D E 92 923 3/8 NPTF 2.75 2.06 2.50 1.25 3.60 1.15 92 925 1/2 NPTF 2.75 2.06 2.50 1.25 3.60 1.05 92 927 3/4 NPTF 2.75 2.06 2.81 1.40 3.88 1.67 802A 8021A 1/2 NPTF 3.63 2.31 3.88 1.75 5.75 3.21 802A 8022A 3/4 NPTF 3.63 2.31 3.88 1.75 5.75 3.00 802A 8024 1 NPTF 5.81 3.68 3.88 2.00 7.50 7.87 802A 8025 1 1/4 NPTF 5.81 3.68 3.88 2.00 7.50 6.92 Wt. Lbs.