The document outlines the calculation of suction air requirements and sizing of hoods and ducts for a dust collection system. A total suction air requirement of 11250 cubic meters per hour is calculated based on individual component needs. Hood sizes are determined based on required air quantities and capture velocities. Duct diameters are sized according to air quantities and designated duct velocities using standard duct sizing formulas. Diameters ranging from 140mm to 445mm are obtained.
The document outlines the calculation of suction air requirements and sizing of hoods and ducts for a dust collection system. A total suction air requirement of 11250 cubic meters per hour is calculated based on individual component needs. Hood sizes are determined based on required air quantities and capture velocities. Duct diameters are sized according to air quantities and designated duct velocities using standard duct sizing formulas. Diameters ranging from 140mm to 445mm are obtained.
Original Description:
Shows the Bag Filter ducting and suction hood design steps
The document outlines the calculation of suction air requirements and sizing of hoods and ducts for a dust collection system. A total suction air requirement of 11250 cubic meters per hour is calculated based on individual component needs. Hood sizes are determined based on required air quantities and capture velocities. Duct diameters are sized according to air quantities and designated duct velocities using standard duct sizing formulas. Diameters ranging from 140mm to 445mm are obtained.
The document outlines the calculation of suction air requirements and sizing of hoods and ducts for a dust collection system. A total suction air requirement of 11250 cubic meters per hour is calculated based on individual component needs. Hood sizes are determined based on required air quantities and capture velocities. Duct diameters are sized according to air quantities and designated duct velocities using standard duct sizing formulas. Diameters ranging from 140mm to 445mm are obtained.
Design Margin 25% Air Quantity Q = 1250 m3/hr Material factor f = 2 Dry and Dusty Suction Air Quantity Q1 = 2500 m3/hr Heavy (Screen Bldg) Q2 = 1250 m3/hr Light (I-Bin) No of Suction Hoods H1 = 4 H2 = 1 Total Suction Air Quantity Q = 11250 m3/hr Hood Design Capture Velocity Vc = 0.8 m/s powder = 2.5 m/s grains = 3 m/s lumps Air quantity Q1 = 0.69 m3/s Also Q1 = Area (A) x Capture Velocity (Vc) Area A1 = 0.87 m2 Hood Size (m x m) H1 = 0.93 x 0.93 Air quantity Q2 0.35 m3/s Also Q2 = Area (A) x Capture Velocity (Vc) Area A2 = 0.434 m2 Hood Size (m x m) H2 = 0.66 x 0.66 Duct Design at Suction Duct Velocity Vd = 22 m/s Horizontal 18 m/s Vertical Suction Air Quantity Q1 = 0.69 m3/s Q1 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct d1 = 0.200 m = 200 mm Suction Air Quantity Q2 = 0.35 m3/s Q2 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct d2 = 0.142 m = 140 mm Duct Design at Intersections Suction Air Quantity Qi1 = 1.39 m3/s Qi1 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct at Suction di1 = 0.284 m = 280 mm Suction Air Quantity Qi2 = 1.39 m3/s Qi2 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct at Suction di2 = 0.284 m = 280 mm Suction Air Quantity Qi3 = 2.78 m3/s Qi3 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct at Suction di3 = 0.401 m = 400 mm Suction Air Quantity Qi4 = 0.69 m3/s Qi4 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct at Suction di4 = 0.200 m = 200 mm Suction Air Quantity Qi4 = 3.47 m3/s Qi4 = (3.14*d*d)/4 x Duct Velocity Vd Diameter of Duct at Suction di4 = 0.448 m = 445 mm