Sepam series 40 is a family of digital units used for current and voltage protection, in any medium or low voltage distribution system.

Uploaded by

Thinh Dao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views2 pages

2 Page S40 Data Sheet

Sepam series 40 is a family of digital units used for current and voltage protection, in any medium or low voltage distribution system.

Uploaded by

Thinh Dao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical data sheet

2005



Electrical network protection

Sepam series 40



Sepam series 40
and its optional modules

1

Base unit, with various User Machine
Interface levels (UMI):

b



basic UMI

b



advanced UMI with graphical LCD screen.

2

Remote advanced UMI.

3

10 logic inputs and 8 output relays,

4 outputs on the base unit + 1 optional
module providing 10 inputs and 4 outputs.

4

1 Modbus communication port:

b

direct connection to 2-wire RS 485,
4-wire RS 485 and fibre optic networks

b

connection to Ethernet TCP/IP network
via PowerLogic Ethernet server
(Transparent Ready).

5

Processing of temperature data
from 16 sensors,

Pt100, Ni100, or Ni120.

6

1 low level analogue output,

0-10 mA, 4-20 mA or 0-20 mA.

7

Software tools:

b

Sepam parameter and protection setting,
control logic customisation

b

local installation operation

b

recovery and display of disturbance
recording data.

Characteristics

Conformity to standards

IEC 60255 Protection relays
IEC 60529 Degree of protection IP52 on front panel
IEC 60068 Operating temperature -25 C to +70 C

Certifications

eee e

, UL508, CSA C22.2

Auxiliary power supply

24-250 V DC and 110-240 V AC

Overall size of base units (H x W x D)

222 x 176 x 130 mm

Sepam

series 40

is a family of



digital units used
for

current

and

voltage

protection, in any medium
or low voltage distribution system.

D
E
5
1
0
2
0

Selection guide

The Sepam series 40 family

includes 7 types:

Specific
protections
available
Applications

Substation Transformer Motor Generator

S40 T40 G40

Directional earth
fault

S41 M41

Directional earth
fault and phase
overcurrent

S42 T42







PCRED301002EN_Ver4.0.fm Page 1 Monday, November 22, 2004 2:10 PM

Schneider Electric Ltd

123 Jack Lane
Leeds
LS10 1BS
Tel: 0870 608 8 608
Fax: 0870 608 8 606
http://www.schneider.co.uk
As standards, specications and designs change from time to time, please ask for conrmation
of the information given in this publication.
DEC 04 MGMV 5659

7 types of Sepam

series

40

b

S40, S41, S42

: substation incomers and
feeders protection

b

T40, T42

: transformer protection

b

M41

: motor protection

b

G40

: generator protection.

Protections ANSI code S40 S41 S42 T40 T42 M41 G40

Phase overcurrent 50/51 4 4 4 4 4 4 4
Voltage restrained overcurrent 50V/51V 1
Earth fault,
sensitive earth fault
50N/51N
50G/51G
4 4 4 4 4 4 4
Breaker failure 50BF 1 1 1 1 1 1 1
Unbalance/negative sequence 46 2 2 2 2 2 2 2

D
E
5
1
0
2
6

Sepam series 40 connection scheme.

Directional phase overcurrent 67 2 2
Directional earth fault 67N/67NC 2 2 2 2
Directional real overpower 32P 1 1 1 1
Directional reactive overpower 32Q/40 1 1
Thermal overload 49 RMS 2 2 2 2
Phase undercurrent 37 1
Locked rotor, excessive starting time 48/51LR/14 1
Starts per hour 66 1
Positive sequence undervoltage 27D 2
Remanent undervoltage 27R 1
Undervoltage 27/27S 2 2 2 2 2 2 2
Overvoltage 59 2 2 2 2 2 2 2
Neutral voltage displacement 59N 2 2 2 2 2 2 2
Negative sequence overvoltage 47 1 1 1 1 1 1 1
Overfrequency 81H 2 2 2 2 2 2 2
Underfrequency 81L 4 4 4 4 4 4 4
Recloser (4 cycles) 79

v v v

Temperature monitoring
(8 or 16 RTDs, 2 set points per RTD)
38/49T

v v v v

Thermostat / Buchholz 26/63

v v

Metering

RMS phase current I1,I2,I3, residual current I0

b b b b b b b

Average current I1, I2, I3
Peak demand current IM1, IM2, IM3

b b b b b b b

Voltage U21, U32, U13, V1, V2, V3
Residual voltage V0

b b b b b b b

Positive sequence voltage Vd / rotation direction,
Negative sequence voltage Vi

b b b b b b b

Frequency

b b b b b b b

Real / reactive / apparent power P, Q, S
Peak demand real/reactive power PM, QM
Power factor

b b b b b b b

Calculated real / reactive energy (W.h, var.h)

b b b b b b b

D
E
5
0
4
7
2

Real/reactive energy impulse counter (W.h, var.h)

v v v v v v v

Temperature

v v v v

Network and machine diagnosis

Tripping current TripI1, TripI2, TripI3, TripI0

b b b b b b b

Tripping context

b b b b b b b

Unbalance ratio/negative sequence current

b b b b b b b

Phase shift


0,


1,


2,


3

b b b b b b b

Disturbance recording

b b b b b b b

Thermal capacity used

b b b b

Remaining operating time before overload tripping

b b b b

Waiting time after overload tripping

b b b b

Running hours counter / operating time

b b b b

Starting current and time

b

Start inhibit time delay, number of starts
before inhibition

b

Switchgear diagnosis

Cumulative breaking current

b b b b b b b

Trip circuit supervision

v v v v v v v

Number of operations, operating time, charging time

v v v v v v v

CT/VT supervision

b b b b b b b

Control and monitoring ANSI code

Circuit breaker / contactor control 94/69

b b b b b b b

Sepam series 40 rear face:


Base unit.

Main connector.
Input current connector.
Modbus communication port.
Link to remote optional modules.
Input voltage connector.


Optional module, 10 inputs and 4 outputs.

Latching / acknowledgment 86

b b b b b b b

Logic discrimination 68

v v v v v v v

Switching of group of settings

b b b b b b b

Annunciation 30

b b b b b b b

Logical equation editor

b b b b b b b

Modbus communication

Measurement readout

v v v v v v v

Remote indication and time tagging of event

v v v v v v v

Remote control orders

v v v v v v v

Remote setting of protections

v v v v v v v

Transfer of disturbance recording data

v v v v v v v
b

standard,

v

according to parameter settings and optional modules.
1
A
B
C
D
E
2

PCRED301002EN_Ver4.0.fm Page 2 Monday, November 22, 2004 2:10 PM