Specifications
Eurotherm Drives, Inc. 1808 Michael Faraday Court, Reston, Virginia 22090-5303, USA (703) 471-4565 Aug-00 HG351943 (3) Page 1 of 4
Installation Instructions
Electrical Shock Hazard Isolate all sources of power before installing this option. Severe injury or
! death could result from unintended actuation of controlled equipment.
Mounting Instructions:
1. Attach the unit to type TS 32 or TS 35 DIN rail. It must not be placed
further than 400 mm from the RS-232 serial port on the main control
board.
Static Sensitive Parts The 5703/2 contains ESD (electrostatic
! discharge) sensitive parts. Observe
static control precautions when handling,
installing, and servicing this assembly.
Additional Instructions:
The 5703/2 requires motor controller software configuration for proper
operation. The default settings in the SSD 590 series controller for the
5703/2 are:
To use the 5703, set the 5703 MODE to 'MASTER' or 'SLAVE.' If a motor
controller is to be a 'SLAVE' then the 'SETPT. RATIO' must be set to a value,
typically 1.0000.
Note: Remember to save the parameters in the controller and update the
configuration record once you have completed your configuration. See
the motor controller product manual for more information.
Eurotherm Drives, Inc. 1808 Michael Faraday Court, Reston, Virginia 22090-5303, USA (703) 471-4565 Aug-00 HG351943 (3) Page 2 of 4
Installation Instructions
The figure below shows the 5703/2 Peer-to-Peer Communications option. The link position determines the signal
transmitted by TX2. When the link connects pins 1 and 2, TX2 re-transmits the input signal from receiver, RX1. When the
link connects pins 2 and 3, TX2 transmits the same signal as TX1. All the remaining configurations are set by software in
the motor controller.
Signal Indicator LEDs
Receiver, RX1
3
Transmitter, TX2 2
1
Link
Figure 3
Figure 4 shows a typical 5703/2 application. The master drive sends a speed setpoint to slave drives 1 and 3. The link is
set to 2 and 3 as shown. Slave drive 3 sends a new setpoint to slave drive 4. It also re-transmits its input setpoint from
the master drive to slave drive 5. The link is set to 1 and 2 as shown.
3 3
Link settings: 2 2
1 1