An Environmentally Friendly Water Treatment System

Introducing the CTMS

Cooling Tower Management System


An INTEGRATED Solution to ALL Cooling Tower Problems
Fouling is defined as the accumulation of dirt,
scale, corrosion products or other materials on
the surface of heat exchangers. This will cause
under-deposit corrosion and ultimately increase
maintenance and energy consumption.
Tr adi t i onal Cool i ng Tower Tr eat ment
Cooling towers are heat exchangers that utilize water and air to transfer process waste
heat to the outdoor environment. Providing cooling water is commonly applicable in air
conditioning, manufacturing and electric power generation. The resurgence of interest in
GREEN technologies and their financial benefits are driving the market towards
environmentally friendly alternatives to solve common cooling tower problems.
As an owner of cooling tower, you are probably
aware of the obvious signs of scale build-up, the
growth of algae, the corrosion and pitting
throughout the tower and chiller system.
Until recently, the options have been limited;
they are often less effective and proven
unsatisfactory. The main alternatives have been
chemical injections, which are costly and harmful
to the environment. Chemicals commonly used
are toxic and highly corrosive to towers.
Consequently, corrosion inhibitor, pH regulator,
antiscalant will be required. All these chemicals
increase the maintenance cost, as well as
causing premature tower replacement and
environmental problems.
Traditionally, chemicals are used to combat the chemical imbalance in cooling water due
to saturation of minerals and pollutants from the air. It is the chemicals themselves that
are part of the problem:
CTMS

does not try to solve the symptoms of the problems, but remove the CAUSE of
the problems with the complete tower management system.
Corrosion
inhibitors
change
the pH
pH
regulator
is used
Biocides
causes
water to
froth
Another
chemical is
used
And so
on...
CTMS

Cooling Tower Management System


CTMS

is the first integrated system to totally maintain and care for your cooling tower.
CTMS

is not just another treatment system. As the name implies, CTMS

is a
complete treatment system and contains important differences that other systems do
not have.
Substantial Energy Savings. Scale with a thickness of 70m is equal to a loss of 11%
thermal efficiency. CTMS

scale control unit will reduce scaling to almost zero and


therefore increase thermal efficiency in tower.
50% Reduction of Blow Down Water. CTMS

does not use a traditional blowdown,


but uses an internal filter to remove solids from the water. CoC is thus increased from
3-4 up to 10-15. As the blow-down water does not contain chemical residue, or silt, the
water can be sent straight to surface water reservoirs or public sewer without further
treatment. In many cases, this water can be re-used for other processes within the
plant.
100% Removal of Bacteria and Biofilm. CTMS

incorporates a unique disinfection


system, which utilizes electrochemical activation (ECA) technology to generate an
ecologically safe, activated solution which displays high level efficacy against all known
microorganisms, including Legionella.
>80% Reduction of Chemicals. By incorporating ECA technology for disinfection
coupled with an electronic descaler for scaling control and an internal filtration system,
fluocculants and descalants are no longer needed. Depending on make-up water
quality, it is possible to achieve 100% reduction of chemicals.
Significant Reduction in Maintenance. CTMS

will keep the tower reservoir clean.


The stand alone system is fully automated. Sediments, corrosion and calcium deposits
are nonexistent. Therefore, the plant does not need to be shut down for periodic
maintenance.
Environmentally Friendly. CTMS

reduces energy, chemicals and water usage.


Before CTMS treatment of AVON (UK)
cooling tower reservoir
After CTMS treatment of AVON (UK)
cooling tower reservoir
CTMS

Cool i ng Tower Management Syst em


COOLI NG TOWER SYSTEM
Common
Problems
Description
Traditional
prevention/
control method
CTMS

Mineral Scale
Fouling
Microbiological
Growth
(Biofilm)
Biocides
Air pollution
Maintenance
Increases opportunities
for bacteria growth
Decreases heat transfer
efficiency
Causes under-deposit
corrosion
Apply chemical
scale inhibitors
AN
ENVIRONMENTALLY
FRIENDLY
SOLUTION
THAT SOLVES ALL
COMMON
PROBLEMS
IN COOLING TOWER
SIMULTANEOUSLY
Decreases heat transfer
efficiency
Corrosive bacteria thrive
under foulants
Apply chemical
treatment or
increase
blow-down
Water borne diseases
(Legionella)
Decreases heat transfer
efficiency
Causes under-deposit
corrosion
Apply chemical
biocides &
corrosion
inhibitor
Highly corrosive and
attack cooling tower
surface
Increases maintenance
cost
Apply chemical
corrosion
inhibitors
Air borne particles
provide a breeding
ground for bacteria while
causing rapid cooling
tube corrosion
Increase
blow-down
Blow-down and cleaning
consumes man-power
and time
Production shut-down for
cleaning
Manual
There is no reason not to let your cooling tower be treated by
CTMS

Case St udy: Pr ovi r on I ndust r i es i n


Hemi k sem, Bel gi um
Proviron Industries transforms recyclable raw materials into durable materials, focusing
on specialty chemicals, biodiesel and custom manufacturing for third parties.
Pr obl em
Close to a housing estate (contamination danger)
Noise prevention
Discharge costs and norm
Cost of traditional water treatment
Tr adi t i onal Tr eat ment
Average chemical cost per month of 198 euro
equaling to 2,376 euro per year
Average maintenance cost per year 6,530 euro
Collection of blow-down 6,144 euro exclusive
labor cost
CTMS

Sol ut i on
To reduce chemical input
To reduce water cost
To reduce waste water cost
To increase tower performance
To reduce maintenance cost
Items
Water cost (at 3.5 /m3)
Chemical cost
Waste water (blow down) removal
Maintenance (contract for 1 year)
Total ()
Traditional ()
1,680
2,376
6,144
6,530
16,730
CTMS ()
168
0
0
3,000
3,158
Savings ()
1,512
2,376
6,144
3,530
13,572
CTMS

installation in Proviron
Industries
Case St udy: Pr ovi r on I ndust r i es i n
Hemi k sem, Bel gi um
In the above table, the following costs have not been calculated:
Process shut down to clean the tower and reservoir
Stocking cost of chemical products
Energy costs (At least 10% energy savings)
Personnel cost
Resul t s
1 year after installation of CTMS

, the conditions of spray arrays, fill packets and


reservoir were investigated.
I n Febr uar y 2000, Pr ovi r on or der ed
2 addi t i onal CTMS

uni t s f or
a new pr oduc t i on l i ne (50m & 10m) at t hei r si t e i n
Hemi k sem.
Spray arrays and fill packet. No evidence
of corrosion or calcium deposits.
Reservoir. The reservoir is clean all year
round.
CTMS

An INTEGRATED
Solution for ALL
Cooling Tower
Problems
A Typi c al Sk i d of CTMS

F
I
L
T
E
R
E
C
A
U
N
I
T
M
O
N
I
T
O
R
I
N
G

C
O
N
T
R
O
L
C
O
N
T
R
O
L
T
O

R
E
S
E
R
V
O
I
R
F
R
O
M

R
E
S
E
R
V
O
I
R
P
U
M
P
B
L
O
W

D
O
W
N
S
C
A
L
E

C
O
N
T
R
O
L
Benef i t s of CTMS

So why switch to CTMS

?
Significant energy savings.
Fully automated.
Environmentally friendly.
Elimination of high operating costs such as
chemicals and cleaning of towers.
Elimination of bacteria and biofilm,
including Legionella in cooling water.
Elimination of scale and fouling throughout
the system resulting in increased overall
operating efficiency.
CTMS

keeps tower and reservoir


clean, removes silts and sediments,
destroys bacteria, algae and biofilm,
reduces scaling to a minimum. All
problems of cooling tower can now be
solved with one integrated system.
NOTE
Install CTMS

now.
Contact us for further information.























For more information contact:

FLOTECH CONTROLS PTE LTD
438 Tagore Industrial Avenue
Singapore 787814
Tel: (65)6553 0366
Fax: (65)6553 0828
Email: [email protected]
Website: www.flotech.com.sg
Reg. No. 198204457H
12_0310

INTRODUCING THE CTMS CTMS


An Environmentally Friendly Water Treatment System
Cooling Tower Management System
The One Solution to All Cooling Towers Problems