Electromagnetic Flowmeter in India

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Electromagnetic Flowmeter in india

ADDMAS a versatile Electromagnetic flow meter [http://addmas.in/]is ideal for conductive liquids such
as Raw Water, Chilled water, effluents, Potable water etc. Using time proven electromagnetic flow
metering principle, the meter achieves a flow meter for pipes from 15mm to 600mm. Since there are no
moving parts, the flow meter gives years of maintenance free service.
ADDMAS flow-head can be supplied in Teflon lining or Hard Rubber lining is available with all the
features required in a field mounted water metering equipments. These include - weather proof
enclosure, communication options, RTC with data logging with printer option and 4 to 20 mA isolated
Flow signal transmission option for flow pattern recording. The converter is available as field mounted-
IP65 protection category. GSM modem interface can also be supplied as an optional add-on feature.
Measuring Principal
The operating principle of Magnetic flow meters is based upon Faraday's Law of electromagnetic
induction, It state that a voltage will be induced in a conductor moving through a magnetic field.
Faraday's Law :
E = kBDV where
E = Induced Voltage
B = Strength of the magnetic field

Application
This Flowmeters find varied applications where the flowing medium is difficult to handle. Major
advantage of these flowmeters are : zero pressure drop, No moving part and highest accuracy level at
most affordable cost. Some of the major application can be described below :
Effluent Treatment plant
Sewage Treatment plant.
Water supply Schemes
Pulp and Papers
Sugar industries and distilleries
Steel and Aluminums
Chemical / Pharmaceuticals
Food and Drugs
Advantages
Tolerates High percentage of suspended solids Sludge, slurries, minerals, paper, sewage flows with
high level of solids which can not be measured other type of meters.
Obstruction less measurements
Nothing projects into the flow stream, no head loss, no parts to maintain.
Pulp and Papers
Sugar industries and distilleries
Suitable for corrosive liquid
Acids, caustic and corrosive additives are isolated from the meter pipe by inert linings and compatible
electrodes.
Suitable for all types of electrically conductive liquids
Liquid where conductivity is of sufficient level to induce measurable

D = Conductor Width
V = Velocity of the conductor
The magnitude of the induced voltage E is directly proportional to the velocity of the conductor width D,
and the strength of the magnetic field B. Liquid acts as a conductor as it flows through pipes.

Technical Specification
Full-Bore EMFM from to 24 sizes
Medium Conductivity : >5 uS/cm
Flow Tube Part : SS 316 / SS 304 (Non Magnetic)
Meter Sizes : 1/2'to 24 Pipe sizes. For Higher size consult Factory.
Electrodes : SS 316L or optionally Hastalloy C
Process Connection : S series: SS 304 M.S. #150 Flange E series: Epoxy painted M.S. #150 Flange
Lining : S series Lining: PTFE E series: Hard Rubber / EPDM / Neoprine
Sensor Housing : Epoxy painted M.S OR SS 304 optional.
Flow Velocity : 0.1 to 10 m/s in two ranges
Pressure Rating : Standard Flanges - ASA150 options on request 15 bar Standard, higher on request
Operating Temperature Medium : S series: 0 to 150 Deg.C for PTFE lining E Series: 0 to 70 DegC for
Hard Rubber lining
Operating Temperature Ambient : 0 to 55 Deg. C
Power Supply : 24Vdc or 230Vac or Battery Operated
Power Consumption : 12VA max
Key Board : 6 Key Membrane Key Board
Electrodes : SS 316L or optionally Hastalloy C
Programmable parameters : Volume Units : ltrs, M3, ML, CF. BG; Time Units: sec, min, hrs- 4 to 20 mA
range, % Low flow cut of, Pipe Dia, Discharge range, Comm. Parameters Calibration Constant, Filter
Constant
Data Logger (Optional) : RTC with 24 column Printer, Battery Charger +SMF Batteries and
Data Transmission(Optional : RS 485 MODBUS RTU or ASCII Protocol or RS232C, HART, with 4 to 20 mA
option as add-on module available
Data Communication (Optional) : An SMS based or GPRS based communication module with software is
available as optional extra. The Modem connects through the RS232C port .The flow meter can be
equipped with GSM Modem. Thus following configuration can be given:
Respond with data to a message (SMS ) from any user. ( Query response mode)
Periodic GPRS based Data transmission to a fixed IP address / users website.
Respond by an SMS to Cell number stored, in case of alarm condition.
Flow parameter : Programmable - Volume Units : ltrs, M3, ML, CF, BG - Time Units : sec, min, hrs
Configurable Parameters : F.S. for 4 to 20 mA range, %Low flow cut off, Communication Parameters
Calibration Constant Damping (Filter)
Calibration : Factory Calibrated on certified flow rig
Ingress protection : IP 65 / IP 67
Electronics Enclosure : Powder coated Die cast Aluminum
Flame proof Version : Please contact factory