Pressure Sensors for general Application
with front flush diaphragm
for gauge pressure and absolute pressure
Accuracy 0.25% and 0.5%
Standard output: 4 . . . 20 mA; 2-wire system
or 0 . . . 5 VDC; 3-wire system
or 0 . . . 10 VDC; 3-wire system
Description
Pressure sensors for general Application are top of the
range pressure transducers.
Their accuracy, reliability, resistance to corrosion and me-
chanical load rating make them suitable for all pressure
measuring tasks - in production, development or in the la-
boratory.
The front flush pressure diaphragm avoids zones, in
which medium could crystallize or residues could form,
thus ensuring trouble-free pressure measurement and
hygienic cleaning of the pressure sensors.
The measuring ranges, graded in accordance with EN,
range from 0.1 bar to 600 bar. The case and wetted parts
comprise stainless steel and are thus resistant to chemi-
cally aggressive media. With the aid of an integrated coo-
ling element, the sensors can be supplied with medium
temperatures up to 150 C.
For more difficult measuring tasks (e.g. hydrostatic co-
lumn), two potentiometers enable the zero point and
measuring range to be set.
The pressure sensors for general Application meet the
electronic magnetic compatibility (EMC) requirements to
EN 61 326.
Features
G For pasty or crystallizing media
G Finely graded selection of nominal pressure
ranges according to EN
G Corrosion resistant stainless steel design
G High overload protection
G Highly resistant to shock and vibration
G For dynamic or static measurements
G Good repeatability
G Integrated cooling element for medium
temperatures up to 150 C
Measuring ranges
Gauge pressure
negative -1 . . . 0 bar to -0.1 . . . 0 bar
positive 0 . . . 0.01 bar to 0 . . . 600 bar
Absolute pressure 0 . . . 0.25 bar to 0 . . . 16 bar
Application
Process engineering,
Plant and apparatus design,
Development and laboratory applications
DE 701 d
P. 1/ 4
Models: 3251, 3252, 3255, 3256, 3344, 3386
DE 701 d
P. 2/ 4
Technical data
Model
Pressure type
Output signal
Accuracy % of F. S.
1
)
Ranges accord. to EN
Sensor element
Repeatability
Stability (annual)
Case
Pressure connection
Wetted parts
Overload limit
Electrical connection
Power supply
Power consumption
Load
Temp. compens. range
Temperature influence
- Zero point
- Measuring range
Adjustability
Response time
Protection type
Emission
4
)
Interference
4
)
Electrical protection types
Temperature ranges
- Storage
- Medium
- Ambient
Weight
negative or positive gauge pressure absolute
pressure
4 . . . 20 mA - 2-wire system
0 . . . 5 VDC - 3-wire system
0 . . . 10 VDC - 3-wire system
0.5 0.25 0.5 0.25 0.5 0.25
0 . . . 0.1 bar
2
) 0 . . . 25 bar 0 . . . 0.25 bar
to to to
0 . . . 16 bar 0 . . . 600 bar 0 . . . 16 bar
piezoresistive thin film piezoresistive
0.05% of F. S.
0.2% of F. S. in rated conditions
Stainless steel
0 . . . 1.6 bar G 1 B; 0 . . . 2.5 bar G 1/2 B
Stainless steel 1.4571
16 bar 3.5 x; 600 bar 2 x; vacuum resistant
Plug to DIN 43 650 with junction box
Round connector M12x1, 4-pin
10 . . . 30 VDC (14 . . . 30 VDC for output 0 . . . 10 V)
output 4 . . . 20 mA: signal current
output 0 . . . 20 mA: signal currency + 4 mA
voltage output: 8 mA
UB - 12 V
for output 4(0) . . . 20 mA
0.020 A
> 5 kOhm for output 0 . . . 5 V
> 10 kOhm for output 0 . . . 10 V
0 . . . 80 C
0.2%/ 10 K
3
)
0.2%/ 10 K
zero point and measuring range up to 10%
1 ms (within 10% to 90% of F. S.)
IP 65 to EN 50 629/ IEC 529
to EN 61 326
to EN 61 326
polarity-, overload- and short-circuit-protection
-40 . . . 100 C
-30 . . . 100 C
-20 . . . 80 C
approx. 0.2 kg
Option
negative and positive
gauge pressure
0 . . . 20 mA;
3-wire system;
other signals
on request
cable outlet with
1 m cable
IP 67 for cable outlet
Medium temperature
-40 . . . 125 C
integrated cooling
element for temperatures
up to 150 C
1
) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis of F. S. = of full scale value
2
) 0.25% accuracy only for ranges 0.25 bar
3
) 0.4% / 10 K for measuring ranges 0 . . . 0.1 and 0 . . . 0.16 bar
4
) Declaration of conformity on request
3251 3252 3386 3344 3255 3256
DE 701 d
P. 3/ 4
Dimensions (mm)
Case
Plug according to DIN 43 650
Accuracy 0.5% Accuracy 0.25% with integrated cooling element cable outlet
Pressure connections
G 1/2 B G 1 B
Weld-on socket or screw-in aperture
G 1/2 G 1
* for long version + 22 mm
tecsis GmbH
An der Sandelmhle 13
D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]
T. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Modifications reserved
4 . . . 20 mA
(2-wire)
1 brown
2 green
-- --
-- --
0 . . . 10 VDC
(3-wire)
1 brown
2 green
3 white
2 green
Supply: UB+
Supply: 0V
Signal: S+
Signal: S-
Connection table for DIN plug or cable outlet
Order details
1. Model
2. Measuring range
3. Output signal
4. Options
DE 701 d
P. 4/ 4
Subject to technical changes
Electrical connection
Two-wire system
DIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plug
cable outlet M12x1
Three-wire system
DIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plug
cable outlet M12x1
brown
green
brown
white
green