G02

Download as pdf or txt
Download as pdf or txt
You are on page 1of 114

System Manual MOVIDRIVE MDX60B/61B Inverter 33

2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
CE-marking, UL approval and C-Tick
Technical Data and Dimension Sheets
2 Technical Data and Dimension Sheets
2.1 CE-marking, UL approval and C-Tick
CE marking Low voltage directive
MOVIDRIVE

MDX60B/61B inverters comply with the regulations of the Low Voltage


Directive 2006/95/EC.
Electromagnetic compatibility (EMC)
The designated use of MOVIDRIVE

inverters and regenerative power supply units


is as components for installation in machinery and systems. They comply with the
EMC product standard EN 61800-3 "Variable-speed electrical drives." Provided the
installation instructions are complied with, they satisfy the relevant requirements for
the CE marking for the entire machine/system in which they are installed, on the
basis of the EMC Directive 89/336/EEC. For detailed information on EMC compliant
installation, refer to the publication "Electromagnetic Compatibility in Drive
Engineering" from SEW-EURODRIVE.
Compliance with limit classes C1 or C2 has been tested on a specified test setup.
SEW-EURODRIVE can provide detailed information on request.

The CE-mark on the nameplate indicates conformity with the low voltage directive
2006/95/EC. We can provide a declaration of conformity on request.
UL / cUL / GOST-
R
UL, cUL approval (USA) and the GOST-R certificate (Russia) have been approved for
the entire MOVIDRIVE

unit series. cUL is equivalent to CSA approval.


C-Tick C-Tick approval has been granted for the entire MOVIDRIVE

range of units. C-Tick


certifies conformity with ACMA (Australian Communications and Media Authority)
standards.
P
i
f
kVA
Hz
n
34 System Manual MOVIDRIVE MDX60B/61B Inverter
2
General technical data
Technical Data and Dimension Sheets
2.2 General technical data
The following table lists the technical data applicable to all MOVIDRIVE

MDX60B/61B
inverters, regardless of their type, version, size and performance.
MOVIDRIVE

MDX60B/61B All sizes


Interference resistance Complies with EN 61800-3
Interference emission with
EMC compliant installation
Sizes 0 to 6 meet EN 61800-3
Sizes 0 to 5: According to limit value class C1 to EN 61800-3 with a
corresponding line filter
Sizes 0, 1, and 2 in accordance with limit value class C2 to EN 61800-3
without additional measures
Size 6 in accordance with limit value class C2 to EN 61800-3 with
corresponding line filter
Ambient temperature
U
I
N
reduction
Ambient temperature
Climate class
0 C...+50 C at I
D
= 100 % I
N
and f
PWM
= 4 kHz
0 C...+40 C at I
D
= 125 % I
N
and f
PWM
= 4 kHz
0 C...+40 C at I
D
= 100 % I
N
and f
PWM
= 8 kHz
2.5 % I
N
per K between 40 C - 50 C
3 % I
N
per K at 50 C - 60 C
EN 60721-3-3, class 3K3
Storage temperature
1)

L
1) In case of long-term storage, the unit must be connected to the mains voltage for at least 5 minutes, other-
wise the units service life may be reduced.
25 C...+70 C (EN 60721-3-3, class 3K3)
DBG keypad: 20 C...+60 C
Cooling type (DIN 41751) Forced cooling
(temperature-controlled fan, response threshold 45 C)
Enclosure EN 60529 (NEMA1)
Sizes 0 to 3
Sizes 4 to 6
IP20
IP00 (power connections)
IP10 (power connections) with
fitted plexiglass cover supplied as standard and
shrink tubing (not included in scope of delivery)
Duty cylce Continuous operation with 50% overload capacity (size 0: 100 %)
Overvoltage category III according to IEC 60664-1 (VDE 0110-1)
Pollution class 2 according to IEC 60664-1 (VDE 0110-1)
Installation altitude h Up to h = 1000 m (3281 ft) without restrictions.
At h 1000 m (3281 ft), the following restrictions apply:
from 1000 m (3281 ft) to max. 4000 m (13120 ft):
I
N
reduction by 1% per 100 m (328 ft)
from 2,000 m (6562 ft) to max. 4000 m (13120 ft):
AC 230 V units: U
N
reduction by AC 3 V per 100 m (328 ft)
AC 500 V units: U
N
reduction by AC 6 V per 100 m (328 ft)
Over 2000 m (6562 ft) only overvoltage class 2, external measures are
required for overvoltage class 3. Overvoltage classes according to
DIN VDE 0110-1.
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 35
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
General technical data
Technical Data and Dimension Sheets
MOVIDRIVE


MDX60B/61B
series, size 0
MOVIDRIVE


MDX61B series,
sizes 1 to 6
51485AXX
Figure 6: MOVIDRIVE

MDX60/61B series, size 0


DEL
OK
DEL
OK
DEL
OK
DEL
OK
52159AXX
Figure 7: MOVIDRIVE

MDX61B series, sizes 1 to 6


P
i
f
kVA
Hz
n
36 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
2.3 MOVIDRIVE

MDX60/61B...-5_3 (AC 400/500 V units)


Size 0
MOVIDRIVE

MDX60/61B 0005-5A3-4-0_ 0008-5A3-4-0_ 0011-5A3-4-0_ 0014-5A3-4-0_


Size 0S 0M
INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V -500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
AC 1.8 A
AC 2.3 A
AC 2.2 A
AC 2.7 A
AC 2.8 A
AC 3.5 A
AC 3.6 A
AC 4.5 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
1.4 kVA 1.6 kVA 2.1 kVA 2.8 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 2 A AC 2.4 A AC 3.1 A AC 4 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V and f
PWM
= 4 kHz)
AC 2.5 A AC 3 A AC 3.8 A AC 5 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V and f
PWM
= 8 kHz) AC 2 A AC 2.4 A AC 3.1 A AC 4 A
Current limitation I
max
Motor and regenerative 200 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0..0.200 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
68
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
42 W 48 W 58 W 74 W
Cooling air consumption 3 m
3
/h 9 m
3
/h
Cross section of unit terminals X1, X2, X3, X4 Disconnectable terminal strip 4 mm
2
conductor end sleeve DIN 46228
Tightening torque 0.6 Nm
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
2) The performance data applies to f
PWM
= 4 kHz.
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 37
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
MDX61B standard version
Design with coated printed circuit boards
0005-5A3-4-00
0005-5A3-4-00/L
0008-5A3-4-00
0008-5A3-4-00/L
0011-5A3-4-00
0011-5A3-4-00/L
0014-5A3-4-00
0014-5A3-4-00/L
Part number
827 722 2
828 947 6
827 723 0
828 948 4
827 724 9
828 949 2
827 725 7
828 950 6
MDX61B Application version
Design with coated printed circuit boards
0005-5A3-4-0T
0005-5A3-4-0T/L
0008-5A3-4-0T
0008-5A3-4-0T/L
0011-5A3-4-0T
0011-5A3-4-0T/L
0014-5A3-4-0T
0014-5A3-4-0T/L
Part number
827 726 5
828 951 4
827 727 3
828 952 2
827 728 1
828 953 0
827 729 X
828 954 9
Constant load
Recommended motor power P
Mot
0.55 kW (0.74 HP) 0.75 kW (1.0 HP) 1.1 kW (1.5 HP) 1.5 kW (2.0 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
0.75 kW (1.0 HP) 1.1 kW (1.5 HP) 1.5 kW (2.0 HP) 2.2 kW (3.0 HP)
Weight 2.0 kg (4.4 lb) 2.5 kg (5.5 lb)
Dimensions W H D
45 mm 317 mm 260 mm
(1.8 in x 12.5 in x 10.2 in)
67,5 mm 317 mm 260 mm
(2.66 in x 12.5 in x 10.2 in)
MDX61B standard version (VFC/CFC/SERVO)
Design with coated printed circuit boards
0005-5A3-4-00
0005-5A3-4-00/L
0008-5A3-4-00
0008-5A3-4-00/L
0011-5A3-4-00
0011-5A3-4-00/L
0014-5A3-4-00
0014-5A3-4-00/L
Part number
827 730 3
828 955 7
827 731 1
828 956 5
827 732 X
828 957 3
827 733 8
828 958 1
MDX61B Application version (VFC/CFC/SERVO)
Design with coated printed circuit boards
0005-5A3-4-0T
0005-5A3-4-0T/L
0008-5A3-4-0T
0008-5A3-4-0T/L
0011-5A3-4-0T
0011-5A3-4-0T/L
0014-5A3-4-0T
0014-5A3-4-0T/L
Part number
827 734 6
828 960 3
827 735 4
828 961 1
827 736 2
828 963 8
827 737 0
828 964 6
Weight 2.3 kg (5.1 lb) 2.8 kg (6.2 lb)
Dimensions W H D
72.5 mm 317 mm 260 mm
(2.85 in 12.5 in 10.2 in)
95 mm 317 mm 260 mm
(3.7 in 12.5 in 10.2 in)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
38 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Size 1 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0015-5A3-4-0_ 0022-5A3-4-0_ 0030-5A3-4-0_ 0040-5A3-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 3.6 A
AC 4.5 A
AC 5.0 A
AC 6.2 A
AC 6.3 A
AC 7.9 A
AC 8.6 A
AC 10.7 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
2.8 kVA 3.8 kVA 4.9 kVA 6.6 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 4 A AC 5.5 A AC 7 A AC 9.5 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V and f
PWM
= 4 kHz)
AC 5 A AC 6.9 A AC 8.8 A AC 11.9 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V and f
PWM
= 8 kHz) AC 4 A AC 5.5 A AC 7 A AC 9.5 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
68
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
85 W 105 W 130 W 180 W
Cooling air consumption 40 m
3
/h
Weight 3.5 kg (7.7 lb)
Dimensions W H D 105 mm 314 mm 234 mm
(4.13 in 12.4 in 9.21 in)
Cross section of unit terminals X1, X2, X3, X4 Disconnectable terminal strip 4 mm
2
conductor end sleeve DIN 46228
Tightening torque 0.6 Nm
MDX61B Standard version
Design with coated printed circuit boards
0015-5A3-4-00
0015-5A3-4-00/L
0022-5A3-4-00
0022-5A3-4-00/L
0030-5A3-4-00
0030-5A3-4-00/L
0040-5A3-4-00
0040-5A3-4-00/L
Part number
827 957 8
1840 013 2
827 958 6
1840 014 0
827 959 4
1840 015 9
827 960 8
1840 016 7
MDX61B Application version
Design with coated printed circuit boards
0015-5A3-4-0T
0015-5A3-4-0T/L
0022-5A3-4-0T
0022-5A3-4-0T/L
0030-5A3-4-0T
0030-5A3-4-0T/L
0040-5A3-4-0T
0040-5A3-4-0T/L
Part number
827 975 6
1840 031 0
827 976 4
1840 032 9
827 977 2
1840 033 7
827 978 0
1840 034 5
Constant load
Recommended motor power P
Mot
1.5 kW (2.0 HP) 2.2 kW (3.0 HP) 3.0 kW (4.0 HP) 4.0 kW (5.4 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
2.2 kW (3.0 HP) 3.0 kW (4.0 HP) 4.0 kW (5.4 HP) 5.5 kW (7.4 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 39
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Sizes 2S, 2 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0055-5A3-4-0_ 0075-5A3-4-0_ 0110-5A3-4-0_


Size 2S 2
INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 11.3 A
AC 14.1 A
AC 14.4 A
AC 18.0 A
AC 21.6 A
AC 27.0 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
8.7 kVA 11.2 kVA 16.8 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 12.5 A AC 16 A AC 24 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz)
AC 15.6 A AC 20 A AC 30 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 8 kHz) AC 12.5 A AC 16 A AC 24 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
47 22
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
220 W 290 W 400 W
Cooling air consumption 80 m
3
/h
Weight 6.6 kg (15 lb)
Dimensions W H D 105 mm 335 mm 294 mm
(4.13 in 13.2 in 11.6 in)
135 mm 315 mm 285 mm
(5.31 in 12.4 in 11.2 in)
Cross section of unit terminals X1, X2, X3, X4
Terminal blocks 4 mm
2
conductor end
sleeves DIN 46228
M4 screw and washer
assembly with terminal clip
4 mm
2
conductor end sleeve
DIN 46228
6 mm
2
crimp cable lug
DIN 46234
Tightening torque 1.5 Nm
MDX61B Standard version
Design with coated printed circuit boards
0055-5A3-4-00
0055-5A3-4-00/L
0075-5A3-4-00
0075-5A3-4-00/L
0110-5A3-4-00
0110-5A3-4-00/L
Part number
827 961 6
1840 017 5
827 962 4
1840 018 3
827 963 2
1840 019 1
MDX61B Application version
Design with coated printed circuit boards
0055-5A3-4-0T 0075-5A3-4-0T 0110-5A3-4-0T
Part number
827 979 9
1840 035 3
827 980 2
1840 036 1
827 981 0
1840 038 8
Constant load
Recommended motor power P
Mot
5.5 kW (7.4 HP) 7.5 kW (10 HP) 11 kW (15 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
7.5 kW (10 HP) 11 kW (15 HP) 15 kW (20 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
40 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Size 3 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0150-503-4-0_ 0220-503-4-0_ 0300-503-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 28.8 A
AC 36 A
AC 41.4 A
AC 51.7 A
AC 54 A
AC 67.5 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
22.2 kVA 31.9 kVA 41.6 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 32 A AC 46 A AC 60 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz)
AC 40 A AC 57.5 A AC 75 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 8 kHz) AC 32 A AC 46 A AC 60 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
15 12
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
550 W 750 W 950 W
Cooling air consumption 180 m
3
/h
Weight 15.0 kg (33 lb)
Dimensions W H D 200 mm 465 mm 308 mm
(7.87 in 18.3 in 12.1 in)
Cross section of unit terminals X1, X2, X3, X4
M6 screw with washer max. 25 mm
2
Crimp cable lug DIN 46234
Tightening torque 3.5 Nm
MDX61B Standard version
Design with coated printed circuit boards
0150-503-4-00
0150-503-4-00/L
0220-503-4-00
0220-503-4-00/L
0300-503-4-00
0300-503-4-00/L
Part number
827 964 0
1840 020 5
827 965 9
1840 021 3
827 966 7
1840 022 1
MDX61B Application version
Design with coated printed circuit boards
0150-503-4-0T
0150-503-4-0T/L
0220-503-4-0T
0220-503-4-0T/L
0300-503-4-0T
0300-503-4-0T/L
Part number
827 982 9
1840 039 6
827 983 7
1840 041 8
827 984 5
1840 042 6
Constant load
Recommended motor power P
Mot
15 kW (20 HP) 22 kW (30 HP) 30 kW (40 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
22 kW (30 HP) 30 kW (40 HP) 37 kW (50 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 41
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Size 4 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0370-503-4-0_ 0450-503-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 65.7 A
AC 81.9 A
AC 80.1 A
AC 100.1 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
51.1 kVA 62.3 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 73 A AC 89 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz)
AC 91 A AC 111 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 8 kHz) AC 73 A AC 89 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
6
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
1200 W 1450 W
Cooling air consumption 180 m
3
/h
Weight 27 kg (60 lb)
Dimensions W H D 280 mm 522 mm 307 mm
(11.0 in 20.6 in 12.1 in)
Cross section of unit terminals X1, X2, X3, X4
M10 bolt with nut
Max. 70 mm
2
Press cable lug DIN 46235
Tightening torque 14 Nm
MDX61B Standard version
Design with coated printed circuit boards
0370-503-4-00
0370-503-4-00/L
0450-503-4-00
0450-503-4-00/L
Part number
827 967 5
1840 024 8
827 968 3
1840 025 6
MDX61B Application version
Design with coated printed circuit boards
0370-503-4-0T
0370-503-4-0T/L
0450-503-4-0T
0450-503-4-0T/L
Part number
827 985 3
1840 043 4
827 986 1
1840 044 2
Constant load
Recommended motor power P
Mot
37 kW (50 HP) 45 kW (60 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
45 kW (60 HP) 55 kW (74 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
42 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Size 5 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0550-503-4-0_ 0750-503-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 94.5 A
AC 118.1 A
AC 117 A
AC 146.3 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
73.5 kVA 91.0 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 105 A AC 130 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz)
AC 131 A AC 162 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 8 kHz) AC 105 A AC 130 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
6 4
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
1700 W 2000 W
Cooling air consumption 360 m
3
/h
Weight 35 kg (77 lb)
Dimensions W H D 280 mm 610 mm 330 mm
(11.0 in 24.0 in 13.0 in)
Cross section of unit terminals X1, X2, X3, X4
M10 bolt with nut
Max. 70 mm
2
Press cable lug DIN 46235
Tightening torque 14 Nm
MDX61B Standard version
Design with coated printed circuit boards
0550-503-4-00
0550-503-4-00/L
0750-503-4-00
0750-503-4-00/L
Part number
827 969 1
1840 026 4
827 970 5
1840 027 2
MDX61B Application version
Design with coated printed circuit boards
0550-503-4-0T
0550-503-4-0T/L
0750-503-4-0T
0750-503-4-0T/L
Part number
827 988 8
1840 045 0
827 989 6
1840 046 9
Constant load
Recommended motor power P
Mot
55 kW (74 HP) 75 kW (100 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
75 kW (100 HP) 90 kW (120 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 43
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60/61B...-5_3 (AC 400/500 V units)
Technical Data and Dimension Sheets
Size 6 (AC 400/500 V units)
MOVIDRIVE

MDX61B 0900-503-4-0_ 1100-503-4-0_ 1320-503-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current
1)
I
supply
100%
(at V
supply
= 3 AC 400 V) 125 %
1) The system and output currents must be reduced by 20 % from the nominal values for V
supply
= 3 AC 500 V.
AC 153 A
AC 191 A
AC 180 A
AC 225 A
AC 225 A
AC 281 A
OUTPUT
Apparent output power
2)
S
N
(at V
supply
= 3 AC 380...500 V)
2) The performance data applies to f
PWM
= 4 kHz.
118 kVA 139 kVA 174 kVA
Rated output current
1)
I
N
(at V
supply
= 3 AC 400 V)
AC 170 A AC 200 A AC 250 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz)
AC 212 A AC 250 A AC 312 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 400 V with f
PWM
= 4 kHz) AC 170 A AC 200 A AC 250 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
2.7
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4 or 8 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
2)
P
Vmax
2300 W 2500 W 2700 W
Cooling air consumption 600 m
3
/h
Weight 60 kg (130 lb)
Dimensions W H D 280 mm 1000 mm 382 mm
(11.0 in 39.37 in 15.0 in
Cross section of unit terminals X1, X2, X3, X4
M12 bolt with nut
Max. 185 mm
2
Press cable lug DIN 46235
Tightening torque 20 Nm
MDX61B Standard version
Design with coated printed circuit boards
0900-503-4-00
0900-503-4-00/L
1100-503-4-00
1100-503-4-00/L
1320-503-4-00
1320-503-4-00/L
Part number
827 971 3
1840 028 0
827 972 1
1840 029 9
827 974 8
1840 030 2
MDX61B Application version
Design with coated printed circuit boards
0900-503-4-0T
0900-503-4-0T/L
1100-503-4-0T
1100-503-4-0T/L
1320-503-4-0T
1320-503-4-0T/L
Part number
827 991 8
1840 047 7
827 992 6
1840 048 5
827 993 4
1840 049 3
Constant load
Recommended motor power P
Mot
90 kW (120 HP) 110 kW (148 HP) 132 kW (177 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
110 kW (148 HP) 132 kW (177 HP) 160 kW (215 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
44 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B...-2_3 (AC 230 V units)
Technical Data and Dimension Sheets
2.4 MOVIDRIVE

MDX61B...-2_3 (AC 230 V units)


Size 1 (AC 230 V units)
MOVIDRIVE

MDX61B 0015-2A3-4-0_ 0022-2A3-4-0_ 0037-2A3-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 200 V - 240 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current I
supply
100 %
(at V
supply
= 3 AC 230 V) 125 %
AC 6.7 A
AC 8.4 A
AC 7.8 A
AC 9.8 A
AC 12.9 A
AC 16.1 A
OUTPUT
Apparent output power
1)
S
N
(at V
supply
= 3 AC 230..0.240 V)
1) The performance data applies to f
PWM
= 4 kHz.
2.7 kVA 3.4 kVA 5.8 kVA
Rated output current I
N
(at V
supply
= 3 AC 230 V)
AC 7.3 A AC 8.6 A AC 14.5 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 4 kHz)
AC 9.1 A AC 10.8 A AC 18.1 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 8 kHz) AC 7.3 A AC 8.6 A AC 14.5 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
27
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
1)
P
Vmax
110 W 126 W 210 W
Cooling air consumption 40 m
3
/h
Weight 2.8 kg (6.2 lb)
Dimensions W H D 105 mm 314 mm 234 mm
(4.13 in 12.4 in 9.21 in)
Cross section of unit terminals X1, X2, X3, X4
Separable terminal block
4 mm
2
conductor end sleeve DIN 46228
Tightening torque 0.6 Nm
MDX61B Standard version 0015-2A3-4-00 0022-2A3-4-00 0037-2A3-4-00
Part number 827 994 2 827 995 0 827 996 9
MDX61B Application version 0015-2A3-4-0T 0022-2A3-4-0T 0037-2A3-4-0T
Part number 828 003 7 828 004 5 828 005 3
Constant load
Recommended motor power P
Mot
1.5 kW (2.0 HP) 2.2 kW (3.0 HP) 3.7 kW (5.0 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
2.2 kW (3.0 HP) 3.7 kW (5.0 HP) 5.0 kW (6.7 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 45
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B...-2_3 (AC 230 V units)
Technical Data and Dimension Sheets
Size 2 (AC 230 V units)
MOVIDRIVE

MDX61B 0055-2A3-4-0_ 0075-2A3-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 200 V - 240 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current I
supply
100 %
(at V
supply
= 3 AC 230 V) 125 %
AC 19.5 A
AC 24.4 A
AC 27.4 A
AC 34.3 A
OUTPUT
Apparent output power
1)
S
N
(at V
supply
= 3 AC 230..0.240 V)
1) The performance data applies to f
PWM
= 4 kHz.
8.8 kVA 11.6 kVA
Rated output current I
N
(at V
supply
= 3 AC 230 V)
AC 22 A AC 29 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 4 kHz)
AC 27.5 A AC 36.3 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 8 kHz) AC 22 A AC 29 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
12
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
1)
P
Vmax
300 W 380 W
Cooling air consumption 80 m
3
/h
Weight 5.9 kg (13 lb)
Dimensions W H D 135 mm 315 mm 285 mm
(5.31 in 12.4 in 11.2 in)
Cross section of unit terminals X1, X2, X3, X4
M4 screw and washer assembly with terminal clip
4 mm
2
conductor end sleeve DIN 46228
6 mm
2
crimp cable lug DIN 46234
Tightening torque 0.6 Nm
MDX61B Standard version 0055-2A3-4-00 0075-2A3-4-00
Part number 827 997 7 827 998 5
MDX61B Application version 0055-2A3-4-0T 0075-2A3-4-0T
Part number 828 006 1 828 008 8
Constant load
Recommended motor power P
Mot
5.5 kW (7.4 HP) 7.5 kW (10 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
7.5 kW (10 HP) 11 kW (15 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
46 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B...-2_3 (AC 230 V units)
Technical Data and Dimension Sheets
Size 3 (AC 230 V units)
MOVIDRIVE

MDX61B 0110-203-4-0_ 0150-203-4-0_


INPUT
Rated supply voltage (to EN 50160) V
supply
3 AC 200 V - 240 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current I
supply
100 %
(at V
supply
= 3 AC 230 V) 125 %
AC 40 A
AC 50 A
AC 49 A
AC 61 A
OUTPUT
Apparent output power
1)
S
N
(at V
supply
= 3 AC 230..0.240 V)
1) The performance data applies to f
PWM
= 4 kHz.
17.1 kVA 21.5 kVA
Rated output current I
N
(at V
supply
= 3 AC 230 V)
AC 42 A AC 54 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 4 kHz)
AC 52.5 A AC 67.5 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 8 kHz) AC 42 A AC 54 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
7.5 5.6
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
1)
P
Vmax
580 W 720 W
Cooling air consumption 180 m
3
/h
Weight 14.3 kg (31.5 lb)
Dimensions W H D 200 mm 465 mm 308 mm
(7.87 in 18.3 in 12.1 in)
Cross section of unit terminals X1, X2, X3, X4
M6 screw and washer assembly with washer
max. 25 mm
2
Crimp cable lug DIN 46234
Tightening torque 3.5 Nm
MDX61B Standard version 0110-203-4-00 0150-203-4-00
Part number 827 999 3 828 000 2
MDX61B Application version 0110-203-4-0T 0150-203-4-0T
Part number 828 009 6 828 011 8
Constant load
Recommended motor power P
Mot
11 kW (15 HP) 15 kW (20 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
15 kW (20 HP) 22 kW (30 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 47
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B...-2_3 (AC 230 V units)
Technical Data and Dimension Sheets
Size 4 (AC 230 V units)
MOVIDRIVE

MDX61B 0220-203-4-0_ 0300-203-4-0_


INPUT
Rated supply voltage (to EN 50160)V
supply
3 AC 200 V - 240 V
Supply frequency f
supply
50 Hz ... 60 Hz 5 %
Rated supply current I
supply
100 %
(at V
supply
= 3 AC 230 V) 125 %
AC 72 A
AC 90 A
AC 86 A
AC 107 A
OUTPUT
Apparent output power
1)
S
N
(at U
supply
= 3 AC 230...240 V)
1) The performance data applies to f
PWM
= 4 kHz.
31.8 kVA 37.8 kVA
Rated output current I
N
(at V
supply
= 3 AC 230 V)
AC 80 A AC 95 A
Continuous output current (= 125 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 4 kHz)
AC 100 A AC 118 A
Continuous output current (= 100 % I
N
)I
D
(at V
supply
= 3 AC 230 V with f
PWM
= 4 kHz) AC 80 A AC 95 A
Current limitation I
max
Motor and regenerative 150 % I
N
, duration depending on capacity utilization
Internal current limitation I
max
= 0...150 % adjustable
Minimum permitted braking R
BRmin
resistor value (4Q operation)
3
Output voltage U
A
Max. V
supply
PWM frequency f
PWM
Can be set: 4/8/12/16 kHz
Speed range/resolution n
A
/ n
A
6000 ... 0 ... +6000 rpm / 0.2 rpm across the entire range
GENERAL INFORMATION
Power loss at S
N
1)
P
Vmax
1100 W 1300 W
Cooling air consumption 180 m
3
/h
Weight 26.3 kg (57 lb)
Dimensions W H D 280 mm 522 mm 307mm
(11.0 in 20.6 in 12.1 in)
Cross section of unit terminals X1, X2, X3, X4
M10 bolt with nut
max. 70 mm
2
Press cable lug DIN 46235
Tightening torque 3.5 Nm
MDX61B Standard version 0220-203-4-00 0300-203-4-00
Part number 828 001 0 828 002 9
MDX61B Application version 0220-203-4-0T 0300-203-4-0T
Part number 828 012 6 828 013 4
Constant load
Recommended motor power P
Mot
22 kW (30 HP) 30 kW (40 HP)
Variable torque load or constant
load without overload
Recommended motor power P
Mot
30 kW (40 HP) 37 kW (50 HP)
Recommended motor power section "Motor selection"
P
i
f
kVA
Hz
n
48 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60/61B electronics data
Technical Data and Dimension Sheets
2.5 MOVIDRIVE

MDX60/61B electronics data


MOVIDRIVE

MDX60/61B General electronics data


Voltage supply X11:1
for setpoint input X11:5
REF1: DC+10 V +5 % / 0 %, I
max
= DC 3 mA
REF2: DC10 V +0 % / 5 %, I
max
= DC 3 mA
Reference voltages for setpoint potentiometer
Setpoint input n1 X11:2/X11:3 AI11/AI12: Voltage or current input, can be set with S11 and P11_, sampling interval 1 ms
(differential input)
Operating mode AI11/AI12
Resolution
Internal resistance
Voltage input:
n1 = DC 0...+10 V or DC 10 V...0...+10 V
12 bit
R
i
= 40 k (external voltage supply)
R
i
= 20 k (supply from REF1/REF2)
Current input:
n1 = DC 0...20 mA or DC 4...20 mA
11 bit
R
i
= 250
Internal setpoints
Parameter set 1: n11/n12/n13 = 6000...0...+6000 rpm
Parameter set 2: n21/n22/n23 = 6000...0...+6000 rpm
Time ranges of the speed ramps
at n = 3000 rpm
1. Ramp t11/t21 Up: 0...2000 s Down: 0..2000 s
2. Ramp t12/t22 Up = down: 0...2000 s
Stop ramp t13/t23 Down: 0...20 s
Emergency ramp t14/t24 Down: 0...20 s
Motor potentiometer t3 Up: 0.2...50 s Down: 0.2...50 s
Auxiliary voltage output
1)
X13:8/X10:8
VO24: V
OUT
= DC 24 V, maximum current carrying capacity I
max
= DC 400 mA
External voltage supply
1)
X10:9 VI24: U
IN
= DC 24 V 15 % / +20 % according to EN 61131-2
Binary inputs
X13:1...X13:6 and X16:1/X16:2
Internal resistance
Isolated (optocoupler), PLC compatible (EN 61131), sampling interval 1 ms
DI...DI5 and DI6/DI7
R
i
3 k, I
E
DC 10 mA
Signal level
DC +13 V...+30 V= "1" = Contact closed
DC3 V...+5 V = "0" = Contact open
according to EN 61131
Function X13:1
X13:2...X13:6, X16:1/X16:2
DI: fixed assigned with "/Controller inhibit"
DI1...DI5, DI6/DI7: Selection option Parameter menu P60_
Binary outputs
1)
X10:3/X10:7 and X16:3...X16:5
1) The unit provides a current of I
max
= DC 400 mA for the DC+24 V outputs (VO24, binary outputs). If this value is insufficient, a DC 24 V
voltage supply must be connected to X10:9 (VI24).
PLC-compatible (EN 61131-2), response time 1ms
DB/DO2 and DO3...DO5
Signal level "0" = DC 0 V "1" = DC +24 V Caution: Do not apply external voltage!
Function X10:3
X10:7, X16:3...X16:5
DB: With fixed assignment "/Brake", I
max
= DC 150 mA, short-circuit proof, protected against
external voltage to DC 30 V
DO2, DO3...DO5: Selection option Parameter menu P62_,
I
max
= DC 50 mA, short-circuit proof, protected against external voltage to DC 30 V
Relay output X10:4...X10:6 DO1: Load capacity of the relay contacts U
max
= DC 30 V, I
max
= DC 800 mA
Function X10:4
X10:5
X10:6
DO1-C: Shared relay contact
DO1-NO: Normally open contact
DO1-NC: NC contact
Selection option Parameter menu P62_
System bus (SBus) X12:1
X12:2
X12:3
DGND: Reference
potential
SC11: SBus high
SC12: SBus low
CAN bus according to CAN specification 2.0, parts A and B, trans-
mission technology according to ISO 11898, max. 64 stations, termi-
nating resistor (120 ) can be activated using DIP switches
RS485 interface X13:10
X13:11
ST11: RS485+
ST12: RS485-
EIA standard, 9.6 kBaud, max. 32 stations
Max. cable length 200 m
Dynamic terminating resistor with fixed installation
TF/TH/KTY input X10:1 TF1: Response threshold at R
TF
2.9 k 10 %
Reference terminals X11:4
X12:1/X13:9/X16:6/X10:2/X10:10
X13:7
AGND: Reference potential for analog signals and terminals X11:1 and X11:5 (REF1/REF2)
DGND: Reference potential for binary signals, system bus, RS485 interface and TF/TH
DCOM: Reference potential for binary inputs X13:1...X13:6 and X16:1/X16:2 (DI...DI5
and DI6/DI7)
Permitted cable cross section
One core per terminal: 0.20...2.5 mm
2
(AWG 24...12)
Two cores per terminal: 0.25...1 mm
2
(AWG 22...17)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 49
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60/61B electronics data
Technical Data and Dimension Sheets
MOVIDRIVE

MDX60/61B General electronics data


Safety contact X17:1
X17:2
X17:3
X17:4
Permitted cable cross section
Power consumption X17:4
Input capacitance X17:4
DGND: Reference potential for X17:3
VO24: : V
OUT
= DC 24 V, only to supply X17:4 of the same unit; it cannot be used to supply
other units.
SOV24: Reference potential for DC+24 V input "Safe stop" (safety contact)
SVI24: DC+24 V input "Safe stop" (safety contact)
One core per terminal: 0.08...1.5 mm
2
(AWG 28...16)
Two cores per terminal: 0.25 ... 1.0 mm
2
(AWG 23...17)
Size 0: 3 W
Size 1: 5 W
Size 2, 2S: 6 W
Size 3: 7.5 W
Size 4: 8 W
Size 5: 10 W
Size 6: 6 W
Size 0: 27 F
Sizes 1...6: 270 F
Time for restart
Time to inhibit output stage
t
A
= 200 ms
t
S
= 200 ms
Signal level
DC +19.2 V...+30 V= "1" = Contact closed
DC30 V...+5 V = "0" = Contact open
P
i
f
kVA
Hz
n
50 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX60B dimension sheets
Technical Data and Dimension Sheets
2.6 MOVIDRIVE

MDX60B dimension sheets


Size 0S
Size 0S with
braking resistor
installed
53019CXX
Figure 8: Dimensions for MDX60B size 0S, dimensions in mm (in)
249 (9.8)
260 (10.2)
45 (1.8)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
53020CXX
Figure 9: Dimensions for MDX60B size 0S with braking resistor, dimensions in mm (in)
249 (9.8)
260 (10.2)
45 (1.8)
71.5 (2.81)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 51
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX60B dimension sheets
Technical Data and Dimension Sheets
Size 0M
Size 0M with
braking resistor
53022CXX
Figure 10: Dimensions for MDX60B size 0M, dimensions in mm (in)
249 (9.8)
67.5 (2.66)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
260 (10.2)
53023CXX
Figure 11: Dimensions for MDX60B size 0M with braking resistor, dimensions in mm (in)
249 (9.8)
67.5 (2.66)
94 (3.7)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
260 (10.2)
P
i
f
kVA
Hz
n
52 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
2.7 MOVIDRIVE

MDX61B dimension sheets


Size 0S
NOTE
For MOVIDRIVE

MDX61B size 0, installing a braking resistor does not affect the


dimensions. Therefore, MOVIDRIVE

MDX61B size 0 dimensions are displayed


without an installed braking resistor.
51381CXX
Figure 12: Dimensions for MDX61B size 0S, dimensions in mm (in)
249 (9.8)
260 (10.2)
72.5 (2.85)
45 (1.8)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 53
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 0M
51378CXX
Figure 13: Dimensions for MDX61B size 0M, dimensions in mm (in)
249 (9.8)
260 (10.2)
95 (3.7)
67.5 (2.66)
6 (0.24)
3
1
7

(
1
2
.
5
)
2
9
2

(
1
1
.
5
)
1
0

(
0
.
3
9
)
5

(
0
.
2
)
2
8
0

(
1
1
)
P
i
f
kVA
Hz
n
54 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 1
52274CXX
Figure 14: Dimensions for MDX61B size 1, dimensions in mm (in)
85 (3.3)
105 (4.13)
3
0
0

(
1
1
.
8
)
7

(
0
.
2
8
)
3
1
4

(
1
2
.
4
)
6 (0.24)
234 (9.21)
6 (0.24)
3
4
3

(
1
3
.
5
)
4
1 2 3
5 6
7 8 9
+/- 0
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 55
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 2S
52273CXX
Figure 15: Dimensions for MDX61B size 2S, dimensions in mm (in)
105 (4.13)
70 (2.8)
5

(
0
.
2
)
3
2
5

(
1
2
.
8
)
3
3
5

(
1
3
.
2
)
7 (0.28)
294 (11.6)
4
1 2 3
5 6
7 8 9
+/- 0
P
i
f
kVA
Hz
n
56 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 2
52276CXX
Figure 16: Dimensions for MDX61B size 2, dimensions in mm (in)
105 (4.13)
6,5 (0.26)
3
0
0

(
1
1
.
8
)
3
1
5

(
1
2
.
4
)
7

(

0
.
2
8
)
130 (5.12)
124.5 (4.9)
1.5
285 (11.2)
3
3
5
.
4

(
1
3
.
2
)
4
1 2 3
5 6
7 8 9
+/- 0
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 57
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 3
52315CXX
Figure 17: Dimensions for MDX61B size 3, dimensions in mm (in)
105 (4.13)
200 (7.87)
4
4
5

(
1
7
.
5
)
4
6
5

(
1
8
.
3
)
9

(
0
.
4
)
7 (0.3)
308 (12.1)
2 (0.08)
P
i
f
kVA
Hz
n
58 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 4
52277CXX
Figure 18: Dimensions for MDX61B size 4, dimensions in mm (in)
280 (11.0)
140 (5.51)
4
9
9

(
1
9
.
6
)
5
2
2

(
2
0
.
6
)
1
2

(
0
.
4
7
)
7 (0.3)
307 (12.1)
2 (0.08)
4
1 2 3
5 6
7 8 9
+/- 0
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 59
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 5
52278CXX
Figure 19: Dimensions for MDX61B size 5, dimensions in mm (in)
280 (11.0)
140 (5.51)
5
9
0

(
2
3
.
2
)
6
1
0

(
2
4
.
0
)
9

(
0
.
4
)
7 (0.3)
2 (0.08)
330 (13.0)
4
1 2 3
5 6
7 8 9
+/- 0
P
i
f
kVA
Hz
n
60 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDX61B dimension sheets
Technical Data and Dimension Sheets
Size 6
58389CXX
Figure 20: Dimensions for MDX61B size 6, dimensions in mm (in)
140 (5.51)
280 (11.0)
1
0
0
0

(
3
9
.
3
7
)
2
0

(
0
.
7
9
)
4
0
2
3
0

(
9
.
0
6
)
2
3
0

(
9
.
0
6
)
2
3
0

(
9
.
0
6
)
2
3
0

(
9
.
0
6
)
9
7
0

(
3
8
.
2
)
11 (0.43)
294 (11.6)
9 (0.4)
2 (0.08)
382 (15.0)
318 (12.5)
(
1
.
6
)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 61
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDR60A regenerative power supply units
Technical Data and Dimension Sheets
2.8 MOVIDRIVE

MDR60A regenerative power supply units


In MOVIDRIVE

inverters operating in regenerative mode (4Q operation), the


MOVIDRIVE

MDR60A regenerative power supply unit can be used as an alternative


to braking resistors. The prerequisite is a powerful supply system. For more detailed
information, refer to the "MOVIDRIVE

MDR60A Regenerative Power Supply Unit"


system manual. This manual can be ordered from SEW-EURODRIVE.
MOVIDRIVE

MDR60A supplies the DC link circuit of the connected MOVIDRIVE

inverter with electrical power from the supply system in motor operation and returns
regenerative power to the supply system in regenerative operation.
UL approval UL and cUL approval has been granted for the entire MOVIDRIVE

MDR60A0370-503-
00 and MDR60A0750-503-00 range of units. cUL is equivalent to CSA approval. The
MOVIDRIVE

MDR60A1320-503-00 unit does not have UL or cUL approval.


Protection and
monitoring
functions
Monitoring and protection against thermal overload.
Detection of power failure within one supply system half-wave.
Overvoltage protection.
54512AXX
Figure 21: MOVIDRIVE

MDR60A regenerative power supply units


P
i
f
kVA
Hz
n
62 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDR60A regenerative power supply units
Technical Data and Dimension Sheets
Features of a
regenerative
power supply unit
compared to an
inverter with
braking resistors
Energy balance: Regenerative power is fed back into the supply system instead of
being converted into waste heat.
Less installation work for several inverters (network and braking resistor connec-
tions). However, a braking resistor is required to bring the drive to a controlled stop
even when there is a disruption in the supply system.
Reduction in use of control cabinet capacity and ventilator power if the braking
resistor used to have to be installed in the control cabinet.
General technical data
MOVIDRIVE

MDR60A 0370-503-00 (size 3)


0750-503-00 (size 4)
1320-503-00 (size 6)
Interference resistance Complies with EN 61800-3 Meets EN 61000-6-1 and EN 61000-6-2
Interference emission with
EMC-compliant installation
Conforms to EN 61800-3
With NF085-503 line filter (size 3)
With NF150-503 line filter (size 4)
Meets EN 61000-6-4 with line filter
NF300-503
Ambient temperature
U
I
N
reduction ambient
temperature
0 C...+40 C
I
N
reduction: 3 % I
N
per K to max. 60 C
0 C...+40 C
I
N
reduction: 3 % I
N
per K to max. 55 C
Climate class EN 60721-3-3, class 3K3
Storage temperature
1)

L
1) In case of long-term storage, the unit must be connected to the mains voltage for at least 5 minutes, otherwise the units service life
may be reduced.
25 C...+70 C (EN 60721-3-3, class 3K3) 25 C...+55 C
(EN 60721-3-3, class 3K3)
Cooling type (DIN 41751) Forced cooling
(temperature-controlled fan, response threshold 50 C)
Forced cooling
(temperature-controlled fan, response
threshold 45 C)
Degree of protection Size 3
EN 60529 Size 4
(NEMA1)
IP20
IP00 (power connections)
IP10 (power connections)
With fitted plexiglass cover supplied as standard
With fitted shrink tubing (not included in scope of
delivery)
IP20
Duty cylce Continous duty with 50 % overload
Overvoltage category III according to IEC 60664-1 (VDE 0110-1)
Pollution class 2 according to IEC 60664-1 (VDE 0110-1)
Installation altitude Up to h = 1000 m (3281 ft) without restrictions.
At h 1000 m (3281 ft), the following restrictions apply:
from 1000 m (3281 ft) to max. 4000 m (13120 ft):
I
N
reduction by 1% per 100 m (328 ft)
From 2000 m (6562 ft) to max. 4000 m (13120 ft):
U
N
reduction by AC 6 V per 100 m (328 ft)
Over 2000 m (6562 ft) only overvoltage class 2, exter-
nal measures are required for overvoltage class 3.
Overvoltage classes according to DIN VDE 0110-1.
h 1000 m (3281 ft):
No limitation
from 1000 m (3281 ft) to max. 4000 m
(13120 ft):
I
N
reduction: 0.5 % per 100 m (328 ft)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 63
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDR60A regenerative power supply units
Technical Data and Dimension Sheets
Technical data for MOVIDRIVE

MDR60A regenerative power supply


MOVIDRIVE

MDR60A 0370-503-00
(size 3)
0750-503-00
(size 4)
1320-503-00
(size 6)
Part number 826 658 1 826 556 9 827 952 7
INPUT
Rated mains voltage (according to EN 50160)
V
supply
3 AC 380 V - 500 V
Supply frequency f
supply
50 Hz - 60 Hz 5 % 40 Hz - 60 Hz 10 %
Rated connected load P
N
37 kW 75 kW 132 kW
Rated supply current I
supply
(at V
supply
= 3 AC 400 V)
AC 66 A AC 117 A AC 260 A
DC LINK
Apparent output power S
A
(at U
supply
= 3 AC 380..0.500 V)
50 kVA 90 kVA 173 kVA
DC link voltage U
DC link
DC 560 V - 780 V
Rated DC link current I
DC link
DC 70 A DC 141 A DC 340 A
Max. DC link current I
DClink_max
DC 105 A DC 212 A DC 410 A
GENERAL INFORMATION
Power loss at P
N
P
Vmax
950 W 1700 W 2650 W
Cooling air consumption 180 m
3
/h 360 m
3
/h 700 m
3
/h
Connection for power terminals X1, X2
(L1, L2, L3 for size 6)
Permitted tightening torque
Permitted cable cross section
M6 screw with washer
3.5 Nm (31 in-lb)
25 mm
2
(AWG4)
M10 terminal studs
14 Nm (120 in-lb)
70 mm
2
(AWG2/0)
M10 terminal studs
3.5 Nm
25 mm
2
(AWG4)
Connection for DC link connection UG
Permitted cable cross section
Permitted tightening torque
- - 150 mm
2
(power supply
connection) / 30 Nm
(270 in-lb)
1)
185 mm
2
(power supply
connection) / 32 Nm
(280 in-lb)
1)
Connection for electronics terminalsX3
(X2 for size 6)
Permitted cable cross section:
One conductor per terminal: 0.20...2.5 mm
2

(AWG24...13)
Two conductors per terminal:0.25...1 mm
2

(AWG23...17)
Permitted cable cross
section:
0.8...4 mm
2

(AWG18...12)
Weight 16 kg (35 lb) 24 kg (53 lb) 90 kg (200 lb)
Dimensions W H D 200 mm 465 mm
221 mm
(7.87 in x 18.3 in x 8.7 in)
280 mm 522 mm
205 mm
(11 in x 20.6 in x 8.07 in)
380 mm 937 mm
395 mm
(15 in x 36.9 in x 15.6 in)
Line choke (always required) ND085-013
L
N
= 0.1 mH
Part number 826 014 1
ND200-0033
L
N
= 0.03 mH
Part number 826 579 8
Already installed
Line filter (optional) NF085-503, part number
827 415 0
NF150-503, part number
827 417 7
NF300-503, part number
827 419 3
For MOVIDRIVE

MDX60B/61B...-5_3 0005 ... 0370 0005 ... 0750 0005 ... 1320
1) Important: Do not apply tightening torque directly at terminals L1, L2, L3 and UG; use a second wrench.
P
i
f
kVA
Hz
n
64 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVIDRIVE MDR60A regenerative power supply units
Technical Data and Dimension Sheets
Dimension draw-
ings for MDR60A
Provide at least 100 mm clearance above and below the unit. There is no need for
clearance at the sides. You can line up the units directly next to one another. With sizes
4 and 6, do not install any components that are sensitive to high temperatures within
300 mm (11.8 in) of the top of the unit, for example contactors or fuses.
54260CXX
Figure 22: Dimension drawing, MDR60A size 3, dimensions in mm (in)
54261CXX
Figure 23: Dimension drawing, MDR60A size 4, dimensions in mm (in)
4
6
5

(
1
8
.
3
)
4
4
5

(
1
7
.
5
)

1
1

(
0
.
4
3
)
7 (0.3)
105 (4.13)
200 (7.87) 221(8.70)
173 (6.81)
5
2
2

(
2
0
.
6
)
5
0
2

(
1
9
.
8
)
1
1

(
0
.
4
3
)
7 (0.3)
140 (5.51)
280 (11.0) 205 (8.07)
160 (6.30)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 65
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVIDRIVE MDR60A regenerative power supply units
Technical Data and Dimension Sheets
DC link
connection
SEW-EURODRIVE recommends using the following cable sets for the DC link connec-
tion. These cable sets offer the appropriate dielectric strength and are also color-coded.
Color coding is necessary because cross-polarity and ground faults could cause irrepa-
rable damage to the connected equipment.
The length of the cables restricts the DC link connection to the permitted length of 5 m.
They can also be cut to length by the customer for connecting several units. The lugs
for connection to the regenerative power supply unit and an inverter are supplied with
the cable set. Use commercially available lugs for connecting additional inverters. The
inverters must then be connected to the regenerative power supply unit in star configu-
ration.
54282CXX
Figure 24: Dimension drawing, MDR60A size 6, dimensions in mm (in)

395 (15.6)
85 (3.3)

1
1
0

(
4
.
3
3
)
8
0
4

(
3
1
.
7
)
3
3

(
1
.
3
)

350 (13.8)
380 (15.0)



8
2

(
3
.
2
)
3
5
0

(
1
3
.
8
)
6
8
0

(
2
6
.
8
)
Cable set type DCP12A DCP13A DCP15A DCP16A
Part number 814 567 9 814 250 5 814 251 3 817 593 4
For connecting MOVIDRIVE

0005 ... 0110 0150 ... 0370 0450 ... 0750 0900 ... 1320
NOTE
Refer to the "MOVIDRIVE

MDR60A Regenerative Power Supply Unit" system manual


for information on the DC link connection. This manual can be ordered from SEW-
EURODRIVE.
P
i
f
kVA
Hz
n
66 System Manual MOVIDRIVE MDX60B/61B Inverter
2
IPOSplus
Technical Data and Dimension Sheets
2.9 IPOS
plus
Description IPOS
plus
positioning and sequence control is integrated into every MOVIDRIVE

inverter as standard. With IPOS


plus
, control functions and positioning tasks can be
performed either simultaneously or independently of one another.
The IPOS
plus
sequence control system makes it possible to run a user program, disre-
garding any encoder feedback or the selected control mode (VFC, CFC, SERVO). In
conjunction with encoder feedback, the IPOS
plus
positioning control provides high-
performance point-to-point positioning. The IPOS
plus
program is written using the
MOVITOOLS

software. Starting up the inverter, accessing parameters and editing


variables are all possible either with the operating software or the DBG60B keypad
(startup in VFC mode only).
Features Program execution independent of encoder feedback and operating mode
The user program is continued even if a unit malfunction occurs (troubleshooting is
possible in the user program)
Three user programs can be run in parallel and independently of one another (task
1, task 2 and task 3, each of them interrupt-capable)
The user programs programmed in assembler can contain up to 3200 program lines
User-friendly and comprehensive control options for the inverter
Access to all available options
Extensive options for communication via system bus (SBus), RS485, RS232 and
fieldbus (direct communication with MOVIMOT

is possible)
Processing of digital and analog input/output signals
With encoder
feedback only
Positioning with selectable travel speed, positioning ramp and jerk limitation
Feedforward for position, speed and torque control loops with minimized lag error
Two touch probe inputs
Ramp types: LINEAR, JERK LIMITED, SINE and SQUARE
Status and monitoring functions: Lag error monitoring, position signal, software and
hardware limit switches
Nine types of reference travel
Possibility of changing the target position, travel speed, positioning ramp and torque
while movement is in progress
Possibility of "Endless positioning"
Override function
Cam control
Synchronous operation and electronic cam
Max. program length of task 1, task 2 and task 3 Total of ca. 3200 program lines
Command processing time per program line Task 1, 2: 1 ... 11 commands/ms can be configured
Task 3: At least 1 command/ms (typical is 40 commands/ms)
Variables 1024, of which 128 (0 ... 127) can be stored to non-volatile memory; range
of values: 2
31
...+(2
31
1)
Touch probe inputs 2 inputs, processing time < 100 s
Sampling interval of digital and analog inputs 1 ms
Digital inputs/outputs 8 inputs / 5 outputs
Analog inputs/outputs 1 input (DC 0...10 V, DC10 V, DC 0...20 mA, DC 4...20 mA)
1 input (DC 0...10 V)
1 output (DC 0...20 mA, DC 4...20 mA)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 67
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DBG60B keypad option
Technical Data and Dimension Sheets
2.10 DBG60B keypad option
Description The basic version of MOVIDRIVE

does not have a DBG60B keypad and can be


upgraded to include the keypad as an option.
Functions Display process values and status
Status displays of the binary inputs / outputs
Error memory and error reset queries
Option to display and set the operating parameters and service parameters
Data backup and transfer of parameter sets to other MOVIDRIVE

units.
User-friendly startup menu for VFC mode
Manual control of MOVIDRIVE

B and MOVITRAC

B
Manual operation of MOVIMOT

( Decentralized technology documentation)


Features Illuminated text display, range of languages
Keypad with 21 keys
Selection between user menu, detailed parameter menu and startup menu in VFC
mode (CFC and SERVO startup is not possible with the DBG60B)
Can be plugged into MOVIDRIVE

Can be connected via extension cable DKG60B (5 m [16.4 ft])


Degree of protection IP40 (EN 60529)
Keypad Language variants Part number
56555AXX
DBG60B-01
DE/EN/FR/IT/ES/PT/NL
(German / English / French / Italian / Spanish / Portuguese /
Dutch)
1820 403 1
DBG60B-02
DE / EN / FR / FI / SV / DA / TR
(German / English / French / Finnish / Swedish / Danish /
Turkish)
1820 405 8
DBG60B-03
DE/EN/FR/RU/PL/CS
(German / English / French / Russian / Polish / Czech)
1820 406 6
DBG60B-04
DE / EN / FR / ZH
(German / English / French / Chinese)
1820 850 9
Door installation
set
1)
Description (= scope of delivery) Part number
DBM60B
Housing for DBG60B (IP65)
DKG60B extension cable, length 5 m
824 853 2
Extension cables Description (= scope of delivery) Part number
DKG60B Length 5 m
4-core, shielded cable
817 583 7
1) The DBG60B keypad is not included in the scope of delivery and must be ordered separately.
P
i
f
kVA
Hz
n
68 System Manual MOVIDRIVE MDX60B/61B Inverter
2
DBG60B keypad option
Technical Data and Dimension Sheets
Dimension draw-
ing for DBG60B
Dimensions in mm (in)
NOTE
The DBG60B keypad option and the interface adapter are plugged into the same
inverter slot (XT) and therefore cannot be used at the same time.
53147CXX
45 (1.8)
18 (0.71)
1
3
5

(
5
.
3
1
)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 69
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DBG60B keypad option
Technical Data and Dimension Sheets
Dimension
drawing for
DBG60B housing
The DBM60B option can be used to mount the keypad close to the inverter (e.g. in the
control cabinet door). The DBM60B option consists of housing in enclosure IP65 and a
5 m DKG60B extension cable.
62899AXX
Figure 25: Dimension drawing for DBG60B housing, dimensions in mm (in)
1
6
(0
.6
3
)
4 (0.2)
R5
1
5
1

(
5
.
9
4
)
1
3
9

(
5
.
4
7
)
5
4
(2
.1
5
)
6
7
(2
.6
)
2
6
(1
.0
)
P
i
f
kVA
Hz
n
70 System Manual MOVIDRIVE MDX60B/61B Inverter
2
DMP11B mounting panel option
Technical Data and Dimension Sheets
2.11 DMP11B mounting panel option
Part number 818 398 8
Description
If a MOVIDRIVE

MD_60A size 2 unit is to be replaced by MOVIDRIVE

MDX61B size
2S, the MDX61B size 2S can be fitted on the existing mounting plate with the DMP11B
mounting panel. New retaining holes do not have to be drilled.
54588AXX
DMP11B
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 71
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DLB11B touch guard option
Technical Data and Dimension Sheets
2.12 DLB11B touch guard option
Part number 823 111 7 (12 pieces included in the scope of delivery)
Description
Degree of protection IP20 can be achieved with touch guard DLB11B for MOVIDRIVE

MDX61B sizes 4 and 5 (AC 500 V units: MDX61B0370/0450/0550/0750; AC 230 V


units: MDX61B0220/0300).
63233AXX
P
i
f
kVA
Hz
n
72 System Manual MOVIDRIVE MDX60B/61B Inverter
2
HIPERFACE encoder card option type DEH11B
Technical Data and Dimension Sheets
2.13 HIPERFACE

encoder card option type DEH11B


Part number 824 310 7
Description The option capable MOVIDRIVE

MDX61B units can be equipped with the


HIPERFACE

encoder card type DEH11B. The encoder card offers one input for the
motor encoder and one input for an external encoder, also referred to as synchronous
encoder. The input for the external encoder can also be used as an output for incremen-
tal encoder simulation.
Electronics data
Option DEH11B
11870AXX
Output for incremental
encoder simulation or
external encoder input
X14:
Output for incremental encoder simu-
lation:
Signal level to RS422
The number of pulses is the
same as on X15 motor encoder
input
External encoder input (max. 200 kHz):
Permitted encoder types:
HIPERFACE

encoder
sin/cos encoder AC 1 V
SS
TTL encoder with negated tracks
Encoder with signal level to RS422
Encoder power supply:
DC+12 V (tolerance range DC 10.5 - 13 V)
I
max
= DC 650 mA
1)
1) Total current load of DC 12 V encoder supply DC 650 mA.
Motor encoder inputX15: Permitted encoder types:
HIPERFACE

encoder
sin/cos encoder AC 1 V
SS
TTL encoder with negated tracks
Encoder with signal level to RS422
Permitted resolution: 128/256/512/1024/2048 increments
Encoder power supply:
DC+12 V (tolerance range DC 10.5 - 13 V)
I
max
= DC 650 mA
1)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 73
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Absolute encoder card option type DEH21B/DIP11B
Technical Data and Dimension Sheets
2.14 Absolute encoder card option type DEH21B/DIP11B
Part numbers DEH21B: 1820 818 5
DIP11B: 824 969 5
Description The DEH21B and DIP11B options extend the MOVIDRIVE

B system to include an SSI


interface for absolute encoders. This option allows the following possibilities for
IPOS
plus
positioning:
No reference travel required when the system is started or after a power failure
Positioning can take place either with the absolute encoder or the incremental
encoder/resolver installed on the motor.
No position switch needed on the travel distance, even without motor encoder feed-
back
Free processing of the absolute position in the IPOS
plus
program
In addition to the basic unit, 8 digital inputs and 8 digital outputs are available with
the DIP1B option.
The absolute encoder can be mounted either on the motor or along the track (e.g.
high-bay warehouse)
Simple encoder adjustment with user-guided startup
Endless positioning in combination with activated modulo function
Electronics data for DEH21B
DEH21B option
11935AXX
Motor encoder connection
X15:
Permitted encoder types:
HIPERFACE

encoder
sin/cos encoder AC 1 V
SS
TTL encoder with negated tracks
Encoder with signal level to RS422
Permitted resolution: 128/256/512/1024/2048 increments
Encoder power supply: ,
DC+12 V (tolerance range DC 10.5 ... 13 V)
I
max
= DC 650 mA
Encoder connection X62: SSI encoder input
Power supply connection
X60:1
24VIN: DC 24 V power supply for encoder connected to X62
Reference terminal X60:2 Reference potential 24VIN
P
i
f
kVA
Hz
n
74 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Absolute encoder card option type DEH21B/DIP11B
Technical Data and Dimension Sheets
Electronics data for DIP11B
DIP11B option
11884AXX
Connection binary inputs X60:1 ... 8
Internal resistance
Signal level (EN 61131)
Function X60:1 ... 8
DI10 ... DI17 isolated via optocoupler, PLC compatible (EN 61131),
scanning time 1 ms
R
i
3 k , I
E
DC 10 mA
DC+13 V ... +30 V = "1" / DC3 V ... +5 V = "0"
DI10 ... DI17: Selection option Parameter menu P61_
Connection binary outputs X61:1 ... 8
Signal level (EN 61131)
Function X61:1 ... 8
DO10 ... DO17, PLC-compatible (EN 61131), short-circuit proof and
protected against external voltage to DC 30 V
Response time 1 ms
DC +24 V = "1" DC 0 V = "0" Important: Do not apply external voltage!
DO10 ... DO17: Selection option Parameter menu P63_
Encoder connection X62: SSI encoder input
Reference terminals X60:9
X60:10
DCOM: Reference potential for binary inputs (DI10 ... DI17)
DGND: Reference potential for binary signals and 24VIN
without jumper X60:9-X60:10 (DCOM-DGND) isolated binary inputs
With jumper X60:9-X60:10 (DCOM-DGND) non-isolated binary inputs
Permitted line cross section One core per terminal: 0.08 ... 1.5 mm
2
(AWG28 ... 16)
Two cores per terminal: 0.25 ... 1 mm
2
(AWG22 .. 17)
Voltage input X61:9 24VIN: Supply voltage DC+24 V for binary outputs DO10 ... DO17 and
encoder (mandatory)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 75
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Resolver card option type DER11B
Technical Data and Dimension Sheets
2.15 Resolver card option type DER11B
Part number 824 307 7
Description Option-capable MOVIDRIVE

MDX61B units can be equipped with resolver card type


DER11B. The resolver card offers one input for the resolver as motor encoder and one
input for an external encoder, also referred to as synchronous encoder. The input for the
external encoder can also be used as an output for incremental encoder simulation.
Electronics data
DER11B option
11871AXX
Output for incremental
encoder simulation or
external encoder input
X14:
Output for incremental encoder
simulation:
Signal level to RS422
The number of pulses is 1024
pulses/revolution
External encoder input (max. 200 kHz):
Permitted encoder types:
HIPERFACE

encoder
sin/cos encoder AC 1 V
SS
TTL encoder with negated tracks
Encoder with signal level to RS422
Encoder power supply:
DC+12 V (tolerance range DC 10.5 - 13 V)
I
max
= DC 650 mA
Motor encoder input X15: Resolver
2-pole, U
ref
= AC 3.5 V
eff
, 4 kHz
U
in
/ U
ref
= 0.5
Maximum cable length: 100 m (328 ft)
P
i
f
kVA
Hz
n
76 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Connector adapter for unit replacement MD_60A - MDX60B/61B
Technical Data and Dimension Sheets
2.16 Connector adapter for unit replacement MD_60A - MDX60B/61B
The following adapters are available for rapid replacement of a MOVIDRIVE

A unit with
a MOVIDRIVE

B unit during system operation.


DAT11B: Terminal adapter, part number 824 671 8
If the TF/TH option is connected to X10 when using MOVIDRIVE

MD_A, then X10


can be directly replugged. The jumper between X10:1 and X10:2 must be removed
if a TF/TH option is connected to encoder input X15. Three plugs have to be rewired.
You can avoid such rewiring work by using the DAT11B terminal adapter. Using this
adapter will prevent incorrect connection and save time. The terminal adapter is
required for terminals X11 (analog input), X12 (SBus) and X13 (binary inputs).
DAE15B: Encoder adapter X15, part number 817 629 9
If a motor with encoder on X15 is in operation on an MDV or MCV, the encoder is
connected via a 9-pin plug connector to MOVIDRIVE

A. Since the DEH11B option


for MOVIDRIVE

MDX61B comes equipped with a 15-pin socket, you will either


have to convert the encoder cable or use the encoder adapter. The encoder adapter
DAE15B for connecting sin/cos and TTL encoders can be inserted directly between
the existing encoder cable with a 9-pin connector and the 15-pin socket on DEH11B.
This step makes for fail-safe and fast connection of existing drives. HTL encoders
have to be connected to MOVIDRIVE

B with the DWE11B/12B option ( section


"DWE11B/12B interface adapter option).
Length of DAE15B: 200 mm 20 mm (7.87 in 0.79 in)
Cable cross section: 6 x 2 x 0.25 mm
2
(AWG 23)
54589AXX
54585AXX
DAT11B
DAE15B
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 77
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Connector adapter for unit replacement MD_60A - MDX60B/61B
Technical Data and Dimension Sheets
DAE14B: Encoder adapter X14, part number 817 630 2
If a synchronous encoder at X14 is operated on a MOVIDRIVE

MDV, MDS, MCV


or MCS unit, connection takes place via a 9-pin socket. Since the DEH11B and
DER11B options for MOVIDRIVE

MDX61B come equipped with a 15-pin plug, you


will either have to rework the encoder cable or use the DAE14B encoder adapter.
The DAE14B encoder adapter can be plugged directly between the existing encoder
cable with 9-pin socket and the 15-pin connector on the DEH11B//DER11B option.
This step makes for fail-safe and fast connection of existing drives.
Length of DAE14B: 200 mm 20 mm (7.87 in 0.79 in)
Cable cross section: 6 x 2 x 0.25 mm
2
(AWG 23)
Terminal of the 15-pin sub D connector
(MOVIDRIVE

MDX61B, option DEH11B, X15)


Core color in
prefabricated cable
Terminal of 9-pin sub
D socket
(encoder end)
1 Yellow (YE) 1
2 Red (RD) 2
3 Pink (PK) 3
4 Violet (VT) 4
8 Brown (BN) 5
9 Green (GN) 6
10 Blue (BU) 7
11 Gray (GY) 8
15 White (WH) 9
54586AXX
Terminal of 15-pin sub D socket
(MOVIDRIVE

MDX61B, option
DEH11B/DER11B, X14)
Core color in prefabricated
cable
Terminal of the 9-pin
sub D connector
(encoder end)
1 Yellow (YE) 1
2 Red (RD) 2
3 Pink (PK) 3
7 Violet (VT) 4
8 Brown (BN) 5
9 Green (GN) 6
10 Blue (BU) 7
11 Gray (GY) 8
15 White (WH) 9
DAE14B
P
i
f
kVA
Hz
n
78 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Interface adapter option type DWE11B/12B
Technical Data and Dimension Sheets
2.17 Interface adapter option type DWE11B/12B
Part number and
description
DWE11B, part number 188 187 6
The interface adapter DWE11B (HTLTTL) in the form of an adapter cable is used
to connect single-ended HTL encoders to the DEH11B/DEH21B option. Only the
A, B and C tracks are connected. The interface adapter is suitable for all HTL
encoders that were operated on MOVIDRIVE

A, MDV and MCV and can be


connected without any rewiring effort.
58748AXX
[A] 5 x 2 x 0.25 mm
2
(AWG 23) / length 1000 mm (39.37 in) /
Max. line length inverter - encoder: 100 m (328 ft)
[B] DC 24 V connection for HTL encoder; 1 x 0.5 mm
2
(AWG
20) / length 250 mm (9.84 in)
Signal Terminal of 9-pin sub D socket [C] (encoder end)
A 1
B 2
C 3
UB 9
GND 5
[C]
[B]
[A]
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 79
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Interface adapter option type DWE11B/12B
Technical Data and Dimension Sheets
DWE12B, part number 188 180 9
The interface adapter DWE12B (HTLTTL) in the form of an adapter cable is used
to connect single-ended HTL encoders to the DEH11B/DEH21B option. In
addition to the A, B and C track, you will also have to connect the negated tracks (A,
B, C). SEW-EURODRIVE recommends using this interface adapter for any new
system.
58748XX
[A] 4 x 2 x 0.25 mm
2
(AWG 23 / length 1000 mm (39.37 in)
Max. line length inverter - encoder: 200 m (656 ft)
[B] DC 24 V connection for HTL encoder; 1 x 0.5 mm
2
(AWG
20) / length 250 mm (9.84 in)
Signal Terminal of 9-pin sub D socket [C] (encoder end)
A 1
A 6
B 2
B 7
C 3
C 8
UB 9
GND 5
[C]
[B]
[A]
P
i
f
kVA
Hz
n
80 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Interface adapter option type UWS11A
Technical Data and Dimension Sheets
2.18 Interface adapter option type UWS11A
Part number 822 689 X
Description The UWS11A option converts RS232 signals, for example from the PC, into RS485
signals. These RS485 signals can then be routed to the RS485 interface of the
MOVIDRIVE

unit (ST11/ST12).
The UWS11A option requires a DC 24 V voltage supply (I
max
= DC 50 mA).
RS232 interface The connection between UWS11A and PC is made using a commercially available
serial interface cable (shielded!).
RS485 interface Max. 32 MOVIDRIVE

units can be networked for communication (max. line length


200 m) via the RS485 interface of the UWS11A. Do not connect external terminating
resistors because dynamic terminating resistors are already installed!
Permitted cable cross section: One core per terminal 0.20...2.5 mm
2
(AWG 24...12)
Two cores per terminal 0.20...1 mm
2
(AWG 24...17)
Dimension
drawing
Dimensions, UWS11A, in mm (in)
The UWS11A option is mounted on a mounting rail (EN 50022-35 7.5) in the control
cabinet.
Technical data
59322BXX
22.5 (0.88)
7
5

(
3
.
0
)
68 (2.7)
83 (3.3)
1
2
3
4
5
24V
RS+
RS-


1
2
3
4
5
X
1
:
R
S
-
4
8
5
X
2
:
R
S
-
2
3
2
UWS
5 (0.2)
UWS11A
Part number 822 689 X
Ambient temperature 0 ... 40 C
Storage temperature 25 C ... +70 C (according to EN 60721-3-3, class 3K3)
Degree of protection IP20
Current consumption max. DC 50 mA
Weight 150 g (0.35 lb)
Dimensions 83 mm x 75 mm x 22.5 mm (3.3 in x 3.0 in x 0.866 in)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 81
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Interface adapter option type UWS21B
Technical Data and Dimension Sheets
2.19 Interface adapter option type UWS21B
Part number 1820 456 2
Description The UWS21B option converts RS232 signals, for example from the PC, into RS485
signals. These RS485 signals can then be routed to the XT slot of MOVIDRIVE

B.
RS232 interface The connection of UWS21B with PC is made using a standard serial interface cable
(shielded).
RS485 interface UWS21B and MOVIDRIVE

B are connected using a serial interface cable with RJ10


connectors.
Scope of delivery The scope of delivery for the UWS21B option includes:
UWS21B unit
Serial interface cable with 9-pin sub D socket and 9-pin sub D connector to connect
the UWS21B option to the PC.
Serial interface cable with two RJ10 connectors to connect UWS21B and
MOVIDRIVE

B.
CD-ROM with MOVITOOLS

Dimension
drawing
Dimensions in mm (in)
Technical data
58558BXX
25 (0.98)
90 (3.5)
96 (3.8)
4
3

(
1
.
7
)
UWS21B
Part number 1 820 456 2
Ambient temperature 0 ... 40 C
Storage temperature 25 C ... +70 C (according to EN 60721-3-3, class 3K3)
Degree of protection IP20
Weight 300 g (0.7 lb)
Dimensions 96 mm x 43 mm x 25 mm (3.8 in x 1.7 in x 0.98 in)
P
i
f
kVA
Hz
n
82 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Interface adapter option type USB11A
Technical Data and Dimension Sheets
2.20 Interface adapter option type USB11A
Part number 824 831 1
Description Option USB11A enables a PC or laptop with a USB interface to be connected to the XT
slot of MOVIDRIVE

B. The USB11A interface adapter supports USB1.1 and USB2.0.


USB11A - PC USB11A is connected to the PC using a commercially available, shielded USB
connection cable type USB A-B.
MOVIDRIVE

-
USB11A
MOVIDRIVE

B and USB11A are connected using a serial interface cable with RJ10
connectors.
Scope of delivery The scope of delivery for the USB11A option includes:
USB11A interface adapter
USB connection cable to connect USB11A - PC
Serial interface cable with two RJ10 connectors to connect USB11A and
MOVIDRIVE

B
CD-ROM with drivers and MOVITOOLS

Dimension
drawing
Dimensions in mm (in)
Technical data
55732CXX
92.5 (3.64) 25 (0.98)
90 (3.0)
4
3

(
1
.
7
)
USB11A
Part number 824 831 1
Ambient temperature 0 ... 40 C
Storage temperature 25 C ... +70 C (according to EN 60721-3-3, class 3K3)
Degree of protection IP20
Weight 300 g (80.7 lb)
Dimensions 92.5 mm x 43 mm x 25 mm (3.64 in x 1.7 in x 0.98 in)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 83
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DC 5 V encoder power supply option type DWI11A
Technical Data and Dimension Sheets
2.21 DC 5 V encoder power supply option type DWI11A
Part number 822 759 4
Description If you are using an incremental encoder with a DC 5 V encoder power supply, install the
DC 5 V encoder power supply option type DWI11A between the inverter and the
incremental encoder. This option provides a regulated DC 5 V power supply for the
encoder. For this purpose, the DC 12 V power supply for the encoder inputs is converted
to DC 5 V by means of a voltage controller. A sensor line is used to measure the supply
voltage at the encoder and compensate the voltage drop along the encoder cable.
Incremental encoders with DC 5 V encoder power supply are not allowed to be
connected directly to the encoder inputs X14: and X15: . This would cause irreparable
damage to the encoder.
Recommendation Use prefabricated cables from SEW for the encoder connection.
Dimension
drawing
Dimensions in mm (in)
The DWI11A option is mounted on a support rail (EN 50022-35 7.5) in the control
cabinet.
Technical data
NOTE
Note that if a short circuit occurs in the sensor cable, the connected encoder may be
exposed to a voltage higher than permitted.
01315DXX
68 (2.7)
73 (2.9)
5 (0.2)
22.5 (0.886)
7
5

(
3
.
0
)
X
2
:
E
n
c
o
d
e
r
X
1
:
M
O
V
I
D
R
I
V
E
DWI
DC 5 V encoder power supply option type DWI11A
Part number 822 759 4
Voltage input DC 10...30 V, I
max
= DC 120 mA
Encoder power supply DC +5 V (up to U
max
+10 V), I
max
= DC 300 mA
Max. line length that can be
connected
100 m (9,997.44 cm) total
Use a shielded twisted-pair cable (A and A, B and B, C and C) for
connecting the encoder to the DWI11A and the DWI11A to
MOVIDRIVE

.
P
i
f
kVA
Hz
n
84 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Input/output card type DIO11B option
Technical Data and Dimension Sheets
2.22 Input/output card type DIO11B option
Part number 824 308 5
Description The number of inputs/outputs of the basic MOVIDRIVE

B unit can be expanded with


the DIO11B option. The DIO11B option is plugged into the fieldbus slot. If the fieldbus
slot is not available, you can plug the DIO11B option into the expansion slot. The
programmable signal types of the additional binary inputs/outputs are the same as the
basic unit ( parameter group P6__, Terminal assignment).
Electronics data
Functions 8 binary inputs
8 binary outputs
1 analog differential input (DC 0...10 V, DC 10 V...+10 V, DC 0...20 mA with
corresponding load)
2 analog outputs (DC10 V ... +10 V, DC 0...20 mA, DC 4...20 mA)
DIO11B option
11872AXX
Setpoint input n2 X20:1/X20:2 AI21/AI22: Voltage input
Differential input or input with AGND reference potential
AI21/AI22 operating mode
Resolution
Internal resistance
n2 = DC 0...+10 V or DC -10 V...0...+10 V
12 bit, sampling time 1 ms
R
i
> 40 k
Analog outputs X21:1/X21:4
X21:2/X21:5
Response time
Resolution
AOV1/AOV2: Voltage outputs DC-10 V...0...+10 V, I
max
= DC 10 mA, short-
circuit proof and protected against external voltage to DC 30 V, selection
option parameter menu P64_
AOC1/AOC2: Current outputs DC 0(4)...20 mA, max. output voltage DC 15 V,
short-cirucit proof and protected against external voltages up to DC 30 V,
selection option parameter menu P64_
5 ms
12 bit
Binary inputs
X22:1...X22:8
Internal resistance
Isolated (optocoupler), PLC compatible (EN 61131)
DI1...DI17
R
i
3 k, I
E
DC 10 mA
Sampling interval 1 ms
Signal level
DC+13 V...+30 V= "1" = Contact closed
DC-3 V...+5 V = "0" = Contact open
Fulfills EN 61131
Function X22:1...X22:8 DI10...DI17: Selection option Parameter menu P61_
Binary outputs X23:1...X23:8 DO1...DO17: PLC-compatible (EN 61131-2), response time 1ms
Signal level "0" = DC 0 V "1" = DC+24 V
Function X23:1...X23:8 DO10...DO17: Selection option Parameter menu P63_,
I
max
= DC 50 mA, short-circuit proof and protected against external voltage to
DC 30 V
Reference terminals
X20:3/X21:3/X21:6
X22:9
X22:10
AGND: Reference potential for analog signals (AI21/AI22/AO_1/AO_2)
DCOM: Reference potential for binary inputs X22:1...X22:8 (DI1...DI17)
DGND: Reference potential for binary signals, reference potential for DC 24
V power supply
Voltage input X23:9 24VIN: Supply voltage DC +24 V for binary outputs DO1...DO17
Permitted line cross section
One core per terminal: 0.08...1.5 mm
2
(AWG 28...16)
Two cores per terminal: 0.25...1 mm
2
(AWG 22...17)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 85
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PROFIBUS fieldbus interface option type DFP21B
Technical Data and Dimension Sheets
2.23 PROFIBUS fieldbus interface option type DFP21B
Part number 824 240 2
Description MOVIDRIVE

B can be equipped with a 12 Mbaud fieldbus interface for the PROFIBUS-


DP serial bus system. The device master data (GSD) and type files for MOVIDRIVE

are available from the SEW homepage (http://www.sew-eurodrive.de) under "Software"


to help with project planning and facilitate startup.
PROFIBUS-DP (Decentralized Periphery) is primarily used at the sensor/actuator level
where fast response times are required. The principal task of PROFIBUS-DP is rapid
cyclic data exchange; e.g. setpoints or binary commands, between central automation
units (PROFIBUS master) and decentralized peripheral units (e.g. drive inverters). The
DFP21B option supports PROFIBUS-DP and DP-V1. Consequently, MOVIDRIVE

B
can be controlled via PLC and PROFIBUS-DP / DP-V1.
Electronics data
DFP21B option
11873AXX
Protocol option
Baud rate
Connection technology
Bus terminator
Station address
GSD file name
DP ID number
Max. number of process data
PROFIBUS-DP and DPV1 to IEC 61158
Automatic detection of baud rate from 9.6 kbaud to 12 Mbaud
9-pin sub D socket, pin assignment to IEC 61158
Not integrated, implement using suitable PROFIBUS connector with terminating
resistors that can be activated
1 ... 125, adjustable via DIP switches
DP: SEW_6003.GSD
DP-V1: SEWA6003.GSD
6003
hex
(24579
dec
)
10 process data
P
i
f
kVA
Hz
n
86 System Manual MOVIDRIVE MDX60B/61B Inverter
2
INTERBUS fieldbus interface option type DFI11B
Technical Data and Dimension Sheets
2.24 INTERBUS fieldbus interface option type DFI11B
Part number 824 309 3
Description MOVIDRIVE

B can be equipped with a fieldbus interface for the non-proprietary and


standardized INTERBUS sensor/actuator bus system.
INTERBUS is defined in EN 50254 / DIN 19258 and, as far as its function is concerned,
it consists of a process data channel and a parameter data channel. Intelligent actuators
such as the MOVIDRIVE

B inverter can be controlled and configured in a user-friendly


way.
Electronics data
DFI11B option
11874AXX
Supported baud rates
Connection technology
DP identity numbers
Max. number of process
data
500 kBaud and 2 MBaud, can be selected via DIP switch
Remote bus input: 9-pin D-sub connector
Remote bus output: 9-pin D-sub socket
RS485 transmission technology, 6-core shielded and twisted-pair cable
E3
hex
= 227
dec
(1 PCP word)
E0
hex
= 224
dec
(2 PCP words)
E1
hex
= 225
dec
(4 PCP words)
38
hex
= 56
dec
(microprocessor not ready)
03
hex
= 3
dec
(no PCP word)
6 process data
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 87
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
INTERBUS-LWL fieldbus interface option type DFI21B (FO)
Technical Data and Dimension Sheets
2.25 INTERBUS-LWL fieldbus interface option type DFI21B (FO)
Part number 824 311 5
Description MOVIDRIVE

B can be equipped with a fieldbus interface for the non-proprietary and


standardized INTERBUS sensor/actuator bus system INTERBUS with fiber optic cables
(INTERBUS-LWL).
INTERBUS is defined in EN 50254 / DIN 19258 and, as far as its function is concerned,
it consists of a process data channel and a parameter data channel. Intelligent actuators
such as the MOVIDRIVE

B inverter can be controlled and configured in a user-friendly


way.
Electronics data
DFI21B option
11875AXX
Supported baud rates
Connection technology
DP identity numbers
Max. number of process data
500 kBaud and 2 MBaud, can be selected via DIP switch
F-SMA connector
E3
hex
= 227
dec
(1 PCP word)
E0
hex
= 224
dec
(2 PCP words)
E1
hex
= 225
dec
(4 PCP words)
38
hex
= 56
dec
(microprocessor not ready)
03
hex
= 3
dec
(no PCP word)
6 process data
P
i
f
kVA
Hz
n
88 System Manual MOVIDRIVE MDX60B/61B Inverter
2
DFE11B fieldbus interface option Modbus/TCP
Technical Data and Dimension Sheets
2.26 DFE11B fieldbus interface option Modbus/TCP
Part number 1820 036 2
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE11B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(MODUBUS/TCP protocol) thanks to its powerful, universal fieldbus interface. You can
use option DFE11B to communicate directly with the inverters via Ethernet and operate
the MOVITOOLS

software to change parameters and IPOS


plus
programs. An inte-
grated Web server makes it possible for the user to access diagnostic values quickly and
easily using a standard browser (e.g. Internet Explorer).
Electronics data
Functions MODBUS/TCP protocol
RJ45 plug connector, star-type cabling
Up to 10 process data and parameter data items can be transferred at the same time
Three ways to allocate the IP address:
1. Set the node address manually (byte 0 or IP address)
2. Make the setting using the DBG60B keypad and MOVITOOLS

3. Use the DHCP server


Engineering access using MOVITOOLS

via Ethernet-TCP/IP
Inverter diagnostics using a standard browser (e.g. Internet Explorer) via the
integrated Web server:
Transfer display values
Configure DFE11B (after login)
Option DFE11B
11876AXX
Application protocols MODBUS/TCP (Transmission Control Protocol) to control and set parameters for
the inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
DHCP (Dynamic Host Configuration Protocol) to assign address parameter auto-
matically.
Port numbers used 502 (MODBUS)
300 (SMLP)
80 (HTTP)
67 / 68 (DHCP)
Ethernet services ARP
ICMP (Ping)
Automatic baud rate detection 10 MBaud / 100 MBaud
Max. number of process data 10 process data
Connection technology RJ45 plug connector
Addressing 4 byte IP address
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 89
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PROFINET IO RT type DFE12B fieldbus interface option
Technical Data and Dimension Sheets
2.27 PROFINET IO RT type DFE12B fieldbus interface option
Part number 1820 563 1
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE12B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(PROFINET/IO protocol) thanks to its powerful, universal fieldbus interface. You can
use option DFE12B to communicate directly with the inverters via Ethernet and operate
the MOVITOOLS

software to change parameters and IPOS


plus
programs. An
integrated Web server makes it possible for the user to access diagnostic values quickly
and easily using a standard browser (e.g. Internet Explorer).
Electronics data
Functions PROFINET IO protocol
RJ45 plug connector, star-type cabling
Up to 10 process data and PROFINET diagnostic parameter data items can be
transferred at the same time
The PROFINET IO controller assigns the IP address
Engineering access using MOVITOOLS

via Ethernet-TCP/IP
Inverter diagnostics using a standard browser (e.g. Internet Explorer) via the
integrated Web server:
Transfer display values
DFE11B configuration (after login)
Option DFE12B
11877AXX
Application protocols PROFINET IO to control and configure the drive inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
Port numbers used 34962 - 34964 (PROFINET IO)
300 (SMLP)
80 (HTTP)
Ethernet services ICMP (ping)
ARP
Transmission rate 100 MBit full duplex
Transmission process 100BASETX
Max. number of process data 10 process data
Connection technology RJ45 plug connector
Auto-negation Yes
GSD file GSDML-V1.0-SEW-DFE12B-xxxxxxxx.xml
(xxxxxxxx is a placeholder for year/month/day)
SEW manufacturer ID 010A
hex
Device ID 0001
hex
Alarms Diagnostic alarm in the event of a unit fault (can be activated)
Diagnostics Yes
Configuration via PROFINET In preparation
Max. number of connections 3
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
P
i
f
kVA
Hz
n
90 System Manual MOVIDRIVE MDX60B/61B Inverter
2
PROFINET IO RT type DFE32B fieldbus interface option
Technical Data and Dimension Sheets
2.28 PROFINET IO RT type DFE32B fieldbus interface option
Part number 1821 345 6
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE32B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(PROFINET/IO protocol) thanks to its powerful, universal fieldbus interface. You can
use option DFE32B to communicate directly with the inverters via Ethernet and operate
the MOVITOOLS

software to change parameters and IPOS


plus
programs. An
integrated Web server makes it possible for the user to access diagnostic values quickly
and easily using a standard browser (e.g. Internet Explorer).
Electronics data
Functions PROFINET IO protocol
Two RJ45 plug connectors for star or line type cabling
Up to 10 process data and PROFINET diagnostic parameter data items can be
transferred at the same time
The PROFINET IO controller assigns the IP address
Engineering access using MOVITOOLS

via Ethernet-TCP/IP
Inverter diagnostics using a standard browser (e.g. Internet Explorer) via the
integrated Web server:
Transfer display values
DFE32B configuration (after login)
DFE32B option
11878AXX
Application protocol PROFINET IO (Ethernet frames with frame identification 8892
hex
) to con-
trol and set parameters for the inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
Port numbers used 300 (SMLP)
80 (HTTP)
Ethernet services ARP
ICMP (Ping)
ISO / OSI layer 2 Ethernet II
Baud rate 100 Mbaud in full duplex process
Connection technology Two RJ45 plug connectors with integrated switch and auto-crossing
Addressing 4 byte IP address or MAC-ID (00:0F:69:xx:xx:xx)
Manufacturer ID
(vendor ID)
010A
hex
Tools for startup MOVITOOLS

MotionStudio version 5.40 and higher.


DBG60B keypad
Firmware status of MOVIDRIVE


MDX61B
Firmware version 824 854 0.17 or higher ( display with P076)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 91
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DFE13B EtherNet/IP fieldbus interface option
Technical Data and Dimension Sheets
2.29 DFE13B EtherNet/IP fieldbus interface option
Part number 1820 565 8
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE13B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(EtherNet/IP protocol) thanks to its powerful, universal fieldbus interface. You can use
option DFE13B to communicate directly with the inverters via Ethernet and operate the
MOVITOOLS

software to change parameters and IPOS


plus
programs. An integrated
Web server makes it possible for the user to access diagnostic values quickly and easily
using a standard browser (e.g. Internet Explorer).
Electronics data
Functions EtherNet/IP protocol
RJ45 plug connector, star-type cabling
Up to 10 process data and parameter data items can be transferred at the same time
Two ways to allocate the IP address:
1. Make the setting using the DBG60B keypad and MOVITOOLS

2. Use the DHCP server


Engineering access using MOVITOOLS

via Ethernet-TCP/IP
Inverter diagnostics using a standard browser (e.g. Internet Explorer) via the
integrated Web server:
Transfer display values
DFE13B configuration (after login)
Option DFE13B
11879AXX
Application protocols EtherNet/IP (Industrial Protocol) to control and set parameters for the drive
inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
DHCP (Dynamic Host Configuration Protocol) to assign address parameter
automatically.
Port numbers used 44818 (Ethernet/IP TCP)
2222 (EtherNet/IP UDP)
300 (SMLP)
80 (HTTP)
67 / 68 (DHCP)
Ethernet services ARP
ICMP (Ping)
Automatic baud rate detection 10 MBaud / 100 MBaud
Max. number of process data 10 process data
Connection technology RJ45 plug connector
Addressing 4 byte IP address
Manufacturer ID 013B
hex
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
P
i
f
kVA
Hz
n
92 System Manual MOVIDRIVE MDX60B/61B Inverter
2
DFE33B EtherNet/IP fieldbus interface option
Technical Data and Dimension Sheets
2.30 DFE33B EtherNet/IP fieldbus interface option
Part number 1821 346 4
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE33B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(EtherNet/IP protocol) thanks to its powerful, universal fieldbus interface. You can use
option DFE33B to communicate directly with the inverters via Ethernet and operate the
MOVITOOLS

software to change parameters and IPOS


plus
programs. An integrated
Web server makes it possible for the user to access diagnostic values quickly and easily
using a standard browser (e.g. Internet Explorer).
Electronics data
Functions EtherNet/IP protocol
Two RJ45 plug connectors for star or line type cabling
Up to 10 process data and parameter data items can be transferred at the same time
Two ways to allocate the IP address:
1. Make the setting using the DBG60B keypad and MOVITOOLS

2. Use the DHCP server


Engineering access using MOVITOOLS

via Ethernet TCP/IP


Inverter diagnostics using a standard browser (e.g. Internet Explorer) via the
integrated Web server:
Transfer display values
DFE33B configuration (after login)
DFE33B option
11880AXX
Application protocol EtherNet/IP (Industrial Protocol) to control and set parameters for the drive
inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
DHCP (Dynamic Host Configuration Protocol) to assign address parameter
automatically.
Port numbers used 44818 (EtherNet/IP TCP)
2222 (EtherNet/IP UDP)
300 (SMLP)
80 (HTTP)
67 / 68 (DHCP)
Ethernet services ARP
ICMP (Ping)
ISO / OSI layer 2 Ethernet II
Automatic baud rate detection 10 MBaud / 100 MBaud
Connection technology Two RJ45 plug connectors with integrated switch and auto-crossing
Addressing 4 byte IP address or MAC-ID (00-0F-69-xx-xx-xx)
Manufacturer ID
(vendor ID)
013B
hex
Tools for startup MOVITOOLS

MotionStudio version 5.40 and higher.


DBG60B keypad
Firmware status of
MOVIDRIVE

MDX61B
Firmware version 824 854 0.17 or higher ( display with P076)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 93
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
EtherCAT fieldbus interface option type DFE24B
Technical Data and Dimension Sheets
2.31 EtherCAT fieldbus interface option type DFE24B
Part number 1821 126 7
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFE24B option to connect


to higher-level automation, project planning and visualization systems via EtherCAT
thanks to its powerful, universal fieldbus interface. You can use option DFE24B to
communicate directly with the inverters via EtherCAT and operate the MOVITOOLS

software to change parameters and IPOS


plus
programs.
Electronics data
Functions EtherCAT
Two RJ45 plug connectors for line type cabling
Simultaneous communication of up to 10 process data and parameter data as well
as access (Rx, Tx) to 8 IPOS
plus
variables
Automatic addressing via EtherCAT master
Engineering access using MOVITOOLS

MotionStudio via EtherCAT


DFE24B option
11881AXX
Standards IEC 61158, IEC 61784-2
Baud rate 100 Mbaud full duplex
Connection technology Two RJ45 plug connectors
Bus terminator Not integrated as bus termination is activated automatically.
OSI layer Ethernet II
Station address Setting via EtherCAT master ( Display with P093)
XML file name SEW_DFE24B.xml
Vendor ID 0x59 (CANopenVendor ID)
EtherCAT services CoE (CANopen over EtherCAT)
VoE (Simple MOVILINK protocol over EtherCAT)
MOVIDRIVE

B firmware status 824 854 0.18 or higher ( isplay with P076)


Tools for startup MOVITOOLS

MotionStudio version 5.40 and higher.


DBG60B keypad
P
i
f
kVA
Hz
n
94 System Manual MOVIDRIVE MDX60B/61B Inverter
2
DeviceNet fieldbus interface option type DFD11B
Technical Data and Dimension Sheets
2.32 DeviceNet fieldbus interface option type DFD11B
Part number 824 972 5
Description The MOVIDRIVE

MDX61B inverter in conjunction with the DFD11B option allows


connection to higher-level automation, project planning and visualization systems via
the open and standardized DeviceNet fieldbus system thanks to the options high-
performance universal fieldbus interface.
The DeviceNet fieldbus interface type DFD11B can be plugged into the fieldbus slot on
all MOVIDRIVE

MDX61B units. The DFD11B option enables communication with the


machine control for a maximum of 10 process data. You need an EDS file to be able to
integrated the DFD11B in the machine control. You can download this file from the SEW
homepage in the Software section.
Electronics data
DFD11B option
11882AXX
Communication protocol Master/slave connection set according to DeviceNet specification version 2.0
Number of process data words Can be set using DIP switch:
1 ... 10 process data words
1 ... 4 process data words with bit-strobe I/O
Baud rate 125, 250 or 500 kbaud, can be set using DIP switch
Bus cable length For thick cable according to DeviceNet specification 2.0 appendix B:
500 m at 125 kBaud
250 m at 250 kBaud
100 m at 500 kBaud
Transmission level ISO 11 98 - 24 V
Connection technology 2-wire bus and 2-wire supply voltage DC 24 V with 5-pole Phoenix terminal
Pin assignment according to DeviceNet specification
MAC ID 0 ... 63, can be set using DIP switch
Max. 64 stations
Supported services Polled I/O: 1 ... 10 words
Bit-strobe I/O: 1 ... 4 words
Explicit messages:
Get_Attribute_Single
Set_Attribute_Single
Reset
Allocate_MS_Connection_Set
Release_MS_Connection_Set
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 95
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
CANopen fieldbus interface option type DFC11B
Technical Data and Dimension Sheets
2.33 CANopen fieldbus interface option type DFC11B
Part number 824 317 4
Description The MOVIDRIVE

MDX61B inverter in conjunction with the DFC11B option allows


connection to higher-level automation, project planning and visualization systems via
the open and standardized CANopen fieldbus system thanks to the options high-
performance universal fieldbus interface. You can also access parameters and process
data using the MOVILINK

protocol designed especially for units from SEW-


EURODRIVE.
The DFC11B fieldbus interface type can be plugged into the fieldbus slot on all
MOVIDRIVE

MDX61B units. in this way, a second system bus (CAN) on MOVIDRIVE

is made available. The DFC11B option enables communication with the machine control
for a maximum of 10 process data. You need an EDS file to be able to integrate the
DFC11B in the higher-level CANopen control. You can download this file from the SEW
homepage in the Software section.
Electronics data
Functions CAN Layer 2 and communication profile MOVILINK

or CANopen
Electrical isolation via optocoupler
DFC11B option
11883AXX
Communication profile SEW-MOVILINK

CANopen
CAN Layer 2
Number of process data words 1 ... 10 process data words
Baud rate Setting using parameter P894:
125 kBaud / 250 kBaud / 500 kBaud / 1 MBaud
Connection technology 9-pole Sub-D plug connector X30 (plug assigned to CIA standard) or
terminal X31
Permitted line cross section X31
(CAN-Bus connection)
One core per terminal: 0.20 ... 2.5 mm
2
(AWG24 ... 12)
Two cores per terminal: 0.25 ...1 mm
2
(AWG22 ... 17)
Terminating resistor 120 (set using DIP switch S1-R)
Addressing Setting via parameter P891 (SBus MOVILINK) or P896 (CANopen)
Tools for startup MOVITOOLS

MotioStudio software
DBG60B keypad
NOTE
If electrical isolation is not required, the CAN-Bus can be connected directly to the basic
unit at X12:SC11/SC12 without the DFC11B option. This does not effect the
functionality.
P
i
f
kVA
Hz
n
96 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Synchronous operation board option type DRS11B
Technical Data and Dimension Sheets
2.34 Synchronous operation board option type DRS11B
Part number 824 672 6
Description The DRS11B option enables a group of motors to run in angular synchronous operation
or in an adjustable proportional relationship. For detailed information, refer to the "Syn-
chronous Operation Board Type DRS11B" manual, which can be ordered from SEW-
EURODRIVE. The basis for synchronous operation is the continuous comparison of the
rotor angle positions of the master and slave motors. The motors must be equipped with
encoders. The DRS11B option is plugged into the expansion slot.
Option DRS11B
11885AXX
Binary inputs X40:1...X40:6
Internal resistance
EING...EING5: isolated (opto-coupler)
PLC compatible (EN 61131)
R
i
3 k, I
E
DC 10 mA
Sampling interval 5 ms
Signal level
DC+13 V...+30 V= "1" = Contact closed
DC3 V...+5 V = "0" = Contact open
Function Fixed assignment with:
EING = Free-running
INP1 = Offset 1
INP2 = Offset 2
INP3 = Offset 3
INP4 = IPOS
plus
variable H477.0
INP5 = IPOS
plus
variable H477.1
Binary outputs X40:9/X40:10 OUTP/OUTP1: PLC compatible (EN 61131-2)
Response time 5 ms
Signal level
"0" = DC 0 V "1" = DC+24 V
Caution: Do not apply external voltage!
Function
Fixed assignment with:
OUTP = IPOS
plus
variable H476.0
OUTP1 = IPOS
plus
variable H476.1
I
max
= DC 50 mA, short-circuit proof, protected against external voltage to
DC 30 V
Reference terminals X40:11
X40:7
Voltage output X40:8
DGND: Reference potential for binary signals
DCOM: Reference potential for binary inputs X40:1...X40:6 (INP...INP5)
VO24: Voltage output DC +24 V, max. DC 100 mA
Synchronous encoder input X41:
Encoder power supply
Max. 200 kHz, signal level according to RS422 or sin/cos
DC +24 V, I
max
= 650 mA
1)
9-pin D-sub socket
Master encoder input X42:
Encoder power supply
Max. 200 kHz, signal level according to RS422 or sin/cos
DC+24 V, I
max
= DC 650 mA
1)
9-pin D-sub socket
Encoder simulation output X43: Signal level to RS422
9-pin D-sub connector
Voltage input X44:1
X44:2
X44:3
GND
DC+24 V supply voltage for binary outputs X40:9/X40:10 and encoder
GND
Permitted line cross section
One core per terminal: 0.08 ... 1.5 mm
2
(AWG28 ... 16)
Two cores per terminal: 0.25 ... 1 mm
2
(AWG22 .. 17)
1) Total current load (X41 and X42) of the DC 24 V encoder supply DC 650 mA
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 97
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PROFIBUS DP-V1 with PROFIsafe fieldbus interface option type DFS11B
Technical Data and Dimension Sheets
2.35 PROFIBUS DP-V1 with PROFIsafe fieldbus interface option type DFS11B
Part number 1820 962 9
Description MOVIDRIVE

B can be equipped with a 12 Mbaud fieldbus interface DFS11B for the


PROFIBUS-DP-V1 serial bus system with PROFIsafe. In addition to cyclical and
acyclical data exchange, safety-oriented communication takes place that allows to
switch a safe F-DO output. The device master data (GSD) and type files for
MOVIDRIVE

are available from the SEW homepage (http://www.sew-eurodrive.de)


under "Software" to help with project planning and facilitate startup.
For more detailed information, refer to the "Fieldbus Interface DFS11B PROFIBUS DP-
V1 with PROFIsafe" manual. You can order this manual from SEW-EURODRIVE.

Electronics data
DFS11B option
11892AXX
PROFIBUS protocol options PROFIBUS DP and DP-V1 according to IEC 61158
Automatic baud rate detection 9.6 kBaud ... 12 MBaud
Connection technology 9-pin D-sub socket
Pin assignment acc. to IEC 61158
Bus terminator Not integrated, implement using suitable PROFIBUS plug with terminating
resistors that can be switched on.
Station address 1 ... 125, adjustable via DIP switches
GSD file name SEW_600C.GSD
DP ID number 600C = 24588
hex
Diagnostics data Max. 8 bytes
Standard diagnostics: 6 bytes
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
F address 1 ... 1022 DIP switch for setting the failsafe address
Ambient temperature 0 to 55 C
P
i
f
kVA
Hz
n
98 System Manual MOVIDRIVE MDX60B/61B Inverter
2
PROFIBUS DP-V1 with PROFIsafe fieldbus interface option type DFS11B
Technical Data and Dimension Sheets
Safety part
Safety characteristics
Highest possible safety category SIL 3 according to EN 61508
Category 4 according to EN 954-1
Performance level e according to EN ISO 13849-1
System structure 2 channels with diagnostics (1002D)
Type of operating mode "High demand" rate according to EN 61508
Probability of dangerous failure per
hour (PFH value)
<1.00E-09 (1 FIT)
Proof test interval (EN61508) 10 years, after which the component must be replaced with a new one
Repair time 100 hours
Safe status Value "0" for all safety-oriented F-DO process values (output disabled)
Safe output
P-M switch
(from load voltage supply)
DC 24 V output according to EN 61131-2, protected against short circuits and overloads
Rated current 1A
Leakage current (at "0" signal) Typically 2 mA (with 2 V / 1 k load resistance)
(Note: Current flows from F-DO_M to F-DO_P)
Internal voltage drop
(P and M output)
max. 3 V
Short circuit protection Electronic, response value: 2.8 A ... 9 A
Overload protection Response value: 1.4 A ... 1.6 A
Load resistance range 24 k ... 1 k
Voltage limitation when switching off
inductive loads
Typically 70 V
Response time (command via
PROFIsafe output switches)
25 ms
Maximum line length 30 m
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 99
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PROFIBUS DP-V1 with PROFIsafe fieldbus interface option type DFS12B
Technical Data and Dimension Sheets
2.36 PROFIBUS DP-V1 with PROFIsafe fieldbus interface option type DFS12B
Part number 1820 963 7 (in preparation)
Description MOVIDRIVE

B can be equipped with a 12 Mbaud fieldbus interface DFS12B for the


PROFIBUS-DP-V1 serial bus system with PROFIsafe. In addition to cyclical and
acyclical data exchange, safety-oriented communication takes place in conjunction with
the DCS21B option. The device master data (GSD) and type files for MOVIDRIVE

are
available from the SEW homepage (http://www.sew-eurodrive.de) under "Software" to
help with project planning and facilitate startup.
For more detailed information, refer to the "Fieldbus Interface DFS12B PROFIBUS DP-
V1 with PROFIsafe" manual. You can order this manual from SEW-EURODRIVE.
Electronics data
DFS12B option
11893AXX
PROFIBUS protocol options PROFIBUS DP and DP-V1 according to IEC 61158
Automatic baud rate detection 9.6 kBaud ... 12 MBaud
Connection technology 9-pin D-sub socket
Pin assignment acc. to IEC 61158
Bus terminator Not integrated, implement using suitable PROFIBUS plug with terminating
resistors that can be switched on.
Station address 1 ... 125, adjustable via DIP switches
GSD file name SEW_600C.GSD
DP ID number 600C = 24588
hex
Diagnostics data Max. 8 bytes
Standard diagnostics: 6 bytes
Tools for startup MOVITOOLS

MotionStudio software
DBG60B keypad
F address The failsafe address is set using the DCS21B option
Ambient temperature 0 to 55 C
P
i
f
kVA
Hz
n
100 System Manual MOVIDRIVE MDX60B/61B Inverter
2
PROFINET IO with PROFIsafe fieldbus interface option, type DFS21B
Technical Data and Dimension Sheets
2.37 PROFINET IO with PROFIsafe fieldbus interface option, type DFS21B
Part number 1821 183 6
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFS21B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(PROFINET/IO RT protocol) thanks to its powerful, universal fieldbus interface. In
addition to cyclical and acyclical data exchange, safety-oriented communication takes
place that allows to switch a safe F-DO output. You can use option DFS21B to
communicate directly with the inverters via Ethernet and operate the MOVITOOLS

software to change parameters and IPOS


plus
programs. An integrated Web server
makes it possible for the user to access diagnostic values quickly and easily using a
standard browser (e.g. Internet Explorer).
For more detailed information, refer to the "Fieldbus Interface DFS21B PROFINET IO
with PROFIsafe" manual. You can order this manual from SEW-EURODRIVE.
Electronics data
DFS21B option
11894AXX
Application protocol PROFINET IO (Ethernet frames with frame identification 8892
hex
) to control and
set parameters for the inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
Port numbers used 300 (SMLP)
80 (HTTP)
Ethernet services ARP
ICMP (Ping)
ISO / OSI layer 2 Ethernet II
Baud rate 100 Mbaud in full duplex process
Connection technology Two RJ45 plug connectors with integrated switch and auto-crossing
Addressing 4 byte IP address or MAC-ID (00:0F:69:xx:xx:xx)
Manufacturer ID
(vendor ID)
010A
hex
Tools for startup MOVITOOLS

MotionStudio version 5.40 and higher.


DBG60B keypad
F address 1 ... 1022 DIP switch for setting the failsafe address
Firmware status of
MOVIDRIVE

MDX61B
Firmware version 824 854 0.17 or higher ( display with P076)
Ambient temperature 0 to 55 C
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 101
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PROFINET IO with PROFIsafe fieldbus interface option, type DFS21B
Technical Data and Dimension Sheets
Safety part
Safety characteristics
Highest possible safety category SIL 3 according to EN 61508
Category 4 according to EN 954-1
Performance level e according to EN ISO 13849-1
System structure 2 channels with diagnostics (1oo2D)
Type of operating mode "High demand" rate according to EN 61508
Probability of dangerous failure per
hour (PFH value)
<1.00E-09 (1 FIT)
Proof test interval (EN61508) 10 years, after which the component must be replaced with a new one
Repair time 100 hours
Safe status Value "0" for all safety-oriented F-DO process values (output disabled)
Safe output
P-M switch
(from load voltage supply)
DC 24 V output according to EN 61131-2, protected against short circuits and overloads
Rated current 1A
Leakage current (at "0" signal) Typically 2 mA (with 2 V / 1 k load resistance)
(Note: Current flows from F-DO_M to F-DO_P)
Internal voltage drop
(P and M output)
max. 3 V
Short circuit protection Electronic, response value: 2.8 A ... 9 A
Overload protection Response value: 1.4 A ... 1.6 A
Load resistance range 24 k ... 1 k
Voltage limitation when switching off
inductive loads
Typically 70 V
Response time (command via
PROFIsafe

output switches)
25 ms
Maximum line length 30 m
P
i
f
kVA
Hz
n
102 System Manual MOVIDRIVE MDX60B/61B Inverter
2
PROFINET IO with PROFIsafe fieldbus interface option, type DFS22B
Technical Data and Dimension Sheets
2.38 PROFINET IO with PROFIsafe fieldbus interface option, type DFS22B
Part number 1821 184 4
Description The MOVIDRIVE

MDX61B inverter enables you to use the DFS22B option to connect


to higher-level automation, project planning and visualization systems via Ethernet
(PROFINET/IO RT protocol) thanks to its powerful, universal fieldbus interface. In
addition to cyclical and acyclical data exchange, safety-oriented communication takes
place in conjunction with the DCS21B option. You can use option DFS22B to communi-
cate directly with the inverters via Ethernet and operate the MOVITOOLS

software to
change parameters and IPOS
plus
programs. An integrated Web server makes it
possible for the user to access diagnostic values quickly and easily using a standard
browser (e.g. Internet Explorer).
For more detailed information, refer to the "Fieldbus Interface DFS22B PROFINET IO
with PROFIsafe" manual. You can order this manual from SEW-EURODRIVE.
Electronics data
DFS22B option
11895AXX
Application protocol PROFINET IO (Ethernet frames with frame identification 8892
hex
) to control and
set parameters for the inverter.
HTTP (Hypertext Transfer Protocol) for diagnostics using a Web browser.
SMLP (Simple Movilink Protocol), protocol used by MOVITOOLS

.
Port numbers used 300 (SMLP)
80 (HTTP)
Ethernet services ARP
ICMP (Ping)
ISO / OSI layer 2 Ethernet II
Baud rate 100 Mbaud in full duplex process
Connection technology Two RJ45 plug connectors with integrated switch and auto-crossing
Addressing 4 byte IP address or MAC-ID (00:0F:69:xx:xx:xx)
Manufacturer ID
(vendor ID)
010A
hex
Tools for startup MOVITOOLS

MotionStudio version 5.40 and higher.


DBG60B keypad
F address The failsafe address is set using the DCS21B option
Firmware status of
MOVIDRIVE

MDX61B
Firmware version 824 854 0.17 or higher ( display with P076)
Ambient temperature 0 ... 55 C
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 103
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVISAFE DCS21B/31B safety module option
Technical Data and Dimension Sheets
2.39 MOVISAFE

DCS21B/31B safety module option


Part numbers DCS21B complete with prefabricated cable DAE34B (CAN bus connection between
DCS21B X86 and DFS21B X31): 1821 895 4
DCS21B without prefabricated cable: 1820 392 2
DCS31B: 1820 958 0
Description The DCS21B and DCS31B options of the MOVISAFE

series are designed as


expansion options for functional safety. They are capable of performing various drive
monitoring functions, such as standstill, speed, direction of rotation or position
monitoring. Additionally, sensor signals can be processed via safe inputs and outputs
and MOVIDRIVE

B can be switched off according to stop categories 0, 1, or 2.


To being able to communicate with a higher-level safety controller in a safety-oriented
manner, the DCS21B option must be used together with the DFS12B fieldbus interface
(PROFIBUS DP-V1) or DFS22B (PROFINET IO). The DCS21B/31B option is plugged
into the expansion slot.
For detailed information, refer to the "Safety Monitor DCS21B/31B" manual, which you
can order from SEW-EURODRIVE.
P
i
f
kVA
Hz
n
104 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVISAFE DCS21B/31B safety module option
Technical Data and Dimension Sheets
Electronics data
DCS21B/31B option
11890AXX
11891AXX
LED alarm/error
LED watchdog
LED system B
LED system A
X80: Power supply connection
X81: Connection binary inputs
X82: Connection of binary outputs DO0, DO1
X83: Connection of binary output DO2
X84: Connection of incremental, sin/cos or absolute encoder (encoder 1)
X85: Connection of incremental, sin/cos or absolute encoder (encoder 2)
X86: CAN bus connection (only for DCS21B)
X87: Connection of service interface
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 105
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVI-PLC basic DHP11B.. controller option
Technical Data and Dimension Sheets
2.40 MOVI-PLC

basic DHP11B.. controller option


Part numbers The MOVI-PLC

basic controller DHP11B.. is available in 3 versions, which differ in the


modules available from a range of libraries.
Description MOVI-PLC

is a series of controllers available from SEW-EURODRIVE. MOVI-PLC

can be programmed by users according to IEC 61131-3 and PLCopen.


The MOVI-PLC

basic controller DHP11B.. is equipped with a PROFIBUS DP-V1 slave


interface, two SBus interfaces (CAN), RS485 and eight digital inputs/outputs, five of
which are interrupt-capable. MOVI-PLC

basic DHP11B.. can control 12 units at the


same time (MOVIDRIVE

B/compact, MOVITRAC

07/B, MOVIAXIS

, MOVIMOT

).
Electronics data
Part number MOVI-PLC

basic DHP11B..
unit version
Description
1820 472 4 DHP11B-T0 MOVI-PLC

basic controller
1820 822 3 DHP11B-T1 Application version I (in addition to version T0, enables
additional functions including electronic cam and
synchronous operation)
1820 823 1 DHP11B-T2 Application version II (in addition to version T1, enables
additional functions including handling)
MOVI-PLC

basic DHP11B.. option


11886AXX
Status displays LEDs for the voltage supply to the I/Os, firmware, program, PROFIBUS, System
buses
Fieldbus PROFIBUS DP and DP-V1 to IEC 61158
Automatic detection of baud rate from 9.6 kbaud to 12 Mbaud
Bus termination with suitable connector to implement
GSD file SEW_6007.GSD
DP ident. number 6007
hex
(24579
dec
)
Maximum 32 process data
System bus 2 system buses (CAN) for control of 12 inverters and CANopen I/O modules
CAN layer 2 (SCOM cyclic, acyclic) or via the SEW MOVILINK

protocol
Baud rate: 125 kBaud ... 1 MBaud
External bus terminator
Address range: 0 ... 127
Engineering Via RS485, PROFIBUS and the system buses
Panel operation Via RS485 and CAN 2 (in preparation)
Connection technology PROFIBUS: 9-pin Sub-D connector to IEC61158
System buses and I/Os: plug-in terminals
RS485: RJ10
Binary inputs / outputs 8 I/Os to IEC 61131-2; can be configured as inputs or outputs. Five are interrupt-
capable
Memory Program: 512 kByte
Data: 128 kByte
Retain: 24 kByte
Tools for startup MOVITOOLS

MotionStudio with integrated PLC editor


(Programming languages IL, ST, LD, FBD, CFC, SFC; libraries to optimize control of
the inverters)
P
i
f
kVA
Hz
n
106 System Manual MOVIDRIVE MDX60B/61B Inverter
2
OST11B option
Technical Data and Dimension Sheets
2.41 OST11B option
Part number 1820 544 5
Description Option OST11B provides an additional RS485 interface (COM2) for MOVI-PLC

basic
DHP11B.. in terminal design or as an engineering interface. Only use option OST11B in
conjunction with MOVI-PLC

basic DHP11B...
When the MOVI-PLC

basic DHP11B.. option is plugged into the fieldbus slot, option


OST11B is plugged into the encoder slot. When the MOVI-PLC

basic DHP11B.. option


is plugged into the expansion slot, option OST11B is installed in the expansion slot
above the option MOVI-PLC

basic DHP11B...
Electronics data
OST11B option
11887AXX
RS485 interface COM2
X35:1 ... X35:4
X36:1 ... X36:3
For connection of an Engineering PC, a DOP11A/B operator terminal or a gear-
motor with integrated frequency inverter MOVIMOT


I/O standard, 57.6 kBaud, max. total cable length 200 m, integrated dynamic
terminating resistor permanently installed
Potential level COM2 is isolated from the MOVI-PLC

basic DHP11B.. controller


P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 107
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVI-PLC advanced controller option DH.41B
Technical Data and Dimension Sheets
2.42 MOVI-PLC

advanced controller option DH.41B


Part numbers The MOVI-PLC

advanced DH.41B is available in 2 variants, which differ in the


integrated fieldbus interfaces:
The MOVI-PLC

advanced controller DH.41B is available as


control card MOVI-PLC

advanced DH.41B as an option for MOVIDRIVE

B and
MOVITRAC

B inverters and for MOVIAXIS

servo inverters
compact controller MOVI-PLC

advanced DHE41B/UOH11B or
DHF41B/UOH21B prepared for installation on a DIN rail. As a compact controller, it
is designed for controlling inverters.
Description MOVI-PLC

is a series of controllers available from SEW-EURODRIVE. MOVI-PLC

can be programmed by users according to IEC 61131-3 and PLCopen.


The MOVI-PLC

advanced controller DH.41B is equipped with numerous communica-


tion interfaces.
The two system bus interfaces CAN 1 and CAN 2 are used primarily for connecting and
controlling several inverters and integrating decentralized I/O modules. SEW-
EURODRIVE recommends connecting a maximum of 256 inputs and 256 outputs to the
MOVI-PLC

advanced DH.41B controller.


This machine module can be operated via the integrated fieldbus interface with a higher-
level controller.
Engineering is carried out using the powerful Ethernet 1 interface or USB interface (in
preparation).
An operator terminal (e.g. DOP11A/B) or a MOVIMOT

gearmotor with integrated


frequency inverter are connected to the RS485 interfaces.
Part number Unit design of MOVI-PLC


advanced DH.41B
Fieldbus interfaces
1821 160 7 DHE41B Ethernet TCP/IP, UDP
1821 161 5 DHF41B Ethernet TCP/IP, UDP, PROFIBUS DP-V1
P
i
f
kVA
Hz
n
108 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVI-PLC advanced controller option DH.41B
Technical Data and Dimension Sheets
Electronics data for DHE41B
MOVI-PLC

advanced DHE41B option


11888AXX
Electrical supply The following applies for all units (MDX, MX, compact controller):
You will have to supply the binary inputs and outputs with DC 24 V (X31:1/2) separately.
Integrated in MOVIDRIVE

MDX61B:
Power consumption: P
max
= 6.8 W
The MOVI-PLC

advanced DHE41B controller is supplied by MOVIDRIVE

MDX61B
via backplane connector.
In the case of disconnection from the power supply, continued function is guaranteed by
DC 24 backup (external DC 24 V supply to X10:9/10 of MOVIDRIVE

MDX61B
required).
Installed in the MOVIAXIS

master module (MXM):


Power consumption: P
max
= 8.5 W
U = DC 24 V (15 % / +20 %)
I
max
= 600 mA
The MOVI-PLC

advanced DHE41B.. controller can be supplied by the MOVIAXIS


switched mode power supply module (MXS) or from an external voltage supply. For this
purpose, connect X5 between the individual devices.
If the MOVI-PLC

advanced DHE41B controller is supplied with DC 24 V by the


MOVIAXIS

switched-mode power supply module, the function of the MOVI-PLC


advanced DHE41B.. controller is maintained after disconnection from the line voltage
(external DC 24 V supply at X16 of the MOVIAXIS

switched-mode power supply


module required).
Potential levels The MOVI-PLC

advanced DHE41B controller has the following potential levels:


Potential control / CAN 1 / COM1
Potential COM2
Potential binary inputs and outputs
Potential system bus CAN 2
Memory Program memory: 8 MByte (for application program, incl. IEC libraries)
Data memory: 4 MByte (for IEC application)
Retain data: 32 kByte
System variables (retain): 8 kByte
Binary inputs
X31:3...X31:10
Internal resistance
Signal level
Isolated (optocoupler), PLC-compatible (IEC 61131-2), cycle time 1 ms, available unfiltered
and filtered (filter constant ca. 2 ms)
Can be configured as binary input or output
X31:6...X31:10 are interrupt capable (response time <100 ms)
R
i
3 k, I
E
10 mA
DC (+13 V...+30 V) = "1" = Contact closed (according to IEC 61131)
DC (3 V...+5 V) = "0" = Contact open (according to IEC 61131)
Binary outputs
X31:3...X31:10
Signal level
PLC compatible, (IEC 61131-2) response time 1 ms
Can be configured as binary input or output
Maximum permitted output current I
A_max
= DC 150 mA per binary output
All 8 binary outputs can be subject to the maximum approved output current I
A_max
load at
the same time.
"0" = 0 V "1" = DC+24 V
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 109
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
MOVI-PLC advanced controller option DH.41B
Technical Data and Dimension Sheets
System bus CAN 2
X32:1 ... X32:3
System bus CAN 1 and CAN 2 to CAN specification 2.0, parts A and B, transmission
technology to ISO 11898, max. 64 stations,
The CAN 2 system bus is electrically isolated
Max. 64 stations per CAN system bus,
Max. 64 SCOM transmit objects / 32 receive objects per CAN system bus
Address range 0...127
Baud rate: 125 kBaud...1 MBaud
If X32 or X33 is the bus terminator, you must connect a terminating resistor (120 )
externally.
You can remove connectors X32 or X33 without interrupting the system bus.
The system bus can be run in layer 2 (SCOM cyclic, acyclic) or in accordance with the
SEW-MOVILINK

protocol.
System bus CAN 1
X33:1 ... X33:3
Ethernet 1 X36 System bus, reserved
Ethernet 2 X37 TCP/IP
Connection options: Engineering PC, other controller, Intranet
USB USB 1.0 for connecting an engineering PC (in preparation)
RS485 Interface
COM1/2
X34:1 ... X34:4
For connection of an engineering PC, a DOP11A/B operator terminal or a MOVIMOT


gearmotor with integrated frequency inverter
I/O standard, 57.6 / 9.6 kBaud, max. cable length 200 m
Dynamic terminating resistor with fixed installation
SD memory card PC readable
Includes:
Firmware
IEC program
Data
At least 128 MB memory
Designs, part numbers, and functions:
OMH41B-T0: 1821 204 2
Functions: Handling of speed control, positioning, e.g. with the MPLCMotion_MDX
library
OMH41B-T1: 1821 205 0
Functions: Additional: cam disk, electronic gear, cam controller, for example
OMH41B-T2: 1821 206 9
Functions: Additional: material handling, for example
Engineering Engineering takes place via one of the following interfaces:
Ethernet 2 (X37)
In preparation: USB (X35)
The engineering of all SEW components connected to the MOVI-PLC

advanced DHE41B
controller can be carried out using the MOVI-PLC

advanced DHE41B controller.


Engineering of the MOVI-PLC

advanced DHE41B controller cannot be performed via the


inverters.
MOVITOOLS

MotionStudio PC software with PLC-Editor


MOVI-PLC

advanced DHE41B option


P
i
f
kVA
Hz
n
110 System Manual MOVIDRIVE MDX60B/61B Inverter
2
MOVI-PLC advanced controller option DH.41B
Technical Data and Dimension Sheets
Electronics data for DHF41B
NOTE
For connections identical with DHE41B, refer to the "Electronics data for DHE41B"
section.
MOVI-PLC

advanced DHF41B option


11889AXX
Potential levels The MOVI-PLC

advanced DHF41B controller has the following potential levels:


Potential control / CAN 1 / COM1
Potential COM2
Potential binary inputs and outputs
Potential system bus CAN 2
Potential PROFIBUS
PROFIBUS connection
X30P:1 ... X30P:9
Bus terminator
Automatic baud rate
recognition
Protocol options
GSD file
DP ID number
Via 9-pin sub D connector, pin assignment according to IEC 61158
Not integrated. Activate bus termination with suitable PROFIBUS connector with
switchable terminating resistors
9.6 kBaud ... 12 MBaud
PROFIBUS DP and DP-V1 to IEC 61158
SEW_6007.GSD
Not yet assigned
DeviceNet connection
X30D:1 ... X30D:5
2-wire bus and 2-wire supply voltage DC 24 V with 5-pole Phoenix terminal
Pin assignment according to DeviceNet specification
Communication protocol Master/slave connection set according to DeviceNet specification version 2.0
Number of process data
words
Programmable via IEC function (0 ... 64 process data words)
A parameter channel can be used as option in addition to the process data words.
Baud rate 125, 250 or 500 kBaud, can be set using DIP switches 2
6
and 2
7
Bus cable length For thick cable according to DeviceNet specification 2.0 appendix B:
500 m at 125 kBaud
250 m at 250 kBaud
100 m at 500 kBaud
Transmission level ISO 11 98 - 24 V
MAC ID 0 ... 63, can be set using DIP switch2
0
... 2
5
Max. 64 stations
Supported services Polled I/O: 1 ... 10 words
Bit-strobe I/O: 1 ... 4 words
Explicit messages:
Get_Attribute_Single
Set_Attribute_Single
Reset
Allocate_MS_Connection_Set
Release_MS_Connection_Set
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 111
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
2.43 Braking resistor type BW... option / BW...-T / BW...-P
General
information
Braking resistors BW... / BW...-T and BW...-P match the technical features of the
MOVIDRIVE

inverters.
Take account of a power reduction of 4 % per 10 K from an ambient temperature of
40 C. Do not exceed a maximum ambient temperature of 80 C.
PTC resistor
BW090-P52B
Direct installation on MOVIDRIVE

MDX60B/61B size 0 (0005 ... 0014) ( chapter


"Dimension drawings MOVIDRIVE

MDX60B")
The MOVIDRIVE

units can be lined up even with mounted braking resistor BW090-


P52B.
The resistor protects itself (reversible) against regenerative overload by changing
abruptly to high resistance and no longer consuming any more energy. The inverter
then switches off and signals a brake chopper fault (F04).
Flat-type braking
resistors
Protection against contact (IP54)
Internal thermal overload protection (non-replaceable fuse)
Touch guard and mounting rail attachment available from SEW as accessories
Wire and grid
resistors
Perforated sheet cover (IP20) open to mounting surface
The short-term load capacity of the wire and grid resistors is higher than in the flat-
type braking resistors ( MOVIDRIVE

MDX60B/61B system manual, chapter.


"Selecting the braking resistor")
A temperature switch is integrated in the BW...-T braking resistor
A thermal overcurrent relay is integrated in the BW...-P braking resistor
SEW-EURODRIVE recommends also protecting the wire and grid resistors against
overload using a bimetallic relay with trip characteristics of trip class 10 or 10A (in
accordance with EN 60947-4-1). Set the trip current to the value I
F
( following tables).
Do not use electronic or electromagnetic fuses because these can be triggered even in
case of short-term excess currents that are still within the tolerance range.
For braking resistors of the BW..-T / BW...-P series, you can connect the integrated
temperature sensor / overcurrent relay using a 2-core, shielded cable as an alternative
to a bimetallic relay. The cable entry for the BW...-T and BW...-P braking resistors can
be run from the front or the back ( dimension drawing for BW... / BW...-T / BW...-P
braking resistors). Use filler plugs for tapped holes that are not connected.
The resistor surfaces will heat up under a load of P
N
. Make sure that you select an
installation site that will accommodate these high temperatures. As a rule, braking
resistors are therefore mounted on the control cabinet roof.
The performance data listed in the tables below show the load capacity of the braking
resistors according to their cyclic duration factor (cyclic duration factor = cdf of the
braking resistor in % in relation to a cycle duration 120 s).
UL and cUL
approval
Type BW... braking resistors are UL and cUL approved in conjunction with
MOVIDRIVE

B inverters. SEW-EURODRIVE will provide a certificate on request. The


BW...-T and BW...-P braking resistors have cRUus approval independent of the
MOVIDRIVE

inverters.
P
i
f
kVA
Hz
n
112 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
Parallel
connection
Two braking resistors with the same value must be connected in parallel for some
inverter/resistor combinations. In this case, the trip current must be set on the bimetallic
relay to twice the value of I
F
entered in the table. For the BW...-T BW...-P braking
resistors, the temperature switch/overcurrent relay must be connected in series.
Assignment to AC 400/500 V units (...-5_3)
Braking resistor type BW...
BW090-
P52B
BW100-
005
BW100-006
BW072-
003
BW072-
005
BW168 BW268
Part number 824 563 0 826 269 1 821 701 7 826 058 3 826 060 5 820 604 X 820 715 1
Braking resistor type BW...-T BW100-006-T BW168-T BW268-T
Part number 1820 419 8 1820 133 4 1820 417 1
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
0.10 kW
0.15 kW
0.2 kW
0.4 kW
0.7 kW
0.45 kW
0.60 kW
0.83 kW
1.11 kW
2.00 kW
0.6 kW
1.1 kW
1.9 kW
3.6 kW
5.7 kW
0.23 kW
0.31 kW
0.42 kW
0.58 kW
1.00 kW
0.45 kW
0.60 kW
0.83 kW
1.11 kW
2.00 kW
0.8 kW
1.4 kW
2.6 kW
4.8 kW
7.6 kW
1.2 kW
2.2 kW
3.8 kW
7.2 kW
11 kW
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
90 35 % 100 10 % 72 10 % 68 10 %
Trip current (of F16) I
F
- 0.8 A
RMS
2.4 A
RMS
0.6 A
RMS
1 A
RMS
3.4 A
RMS
4.2 A
RMS
Design PTC Flat-design
Wire resistor
on ceramic
core
Flat-design
Wire resistor on ceramic
core
Connections /
Tightening torque
Cable Cable
Ceramic termi-
nals 2.5 mm
2

(AWG13)
0.5 Nm
Cable
Ceramic terminals 2.5
mm
2
(AWG13)
0.5 Nm
Degree of protection IP20 IP54
IP20 (when
installed)
IP54 IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended)
0005 ...
0014
0005 ...
0022
0015 ... 0040 0005 ... 0014
0005 ...
0040
0015 ...
0040
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 113
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
Braking resistor type BW... BW147 BW247 BW347 BW039-012
Part number 820 713 5 820 714 3 820 798 4 821 689 4
Braking resistor type BW...-T BW147-T BW247-T BW347-T BW039-012-T BW039-026-T BW039-050-T
Part number 1820 134 2 1820 084 2 1820 135 0 1820 136 9 1820 415 5 1820 137 7
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
1.2 kW
2.2 kW
3.8 kW
7.2 kW
11 kW
2.0 kW
3.6 kW
6.4 kW
12 kW
19 kW
4.0 kW
7.2 kW
12.8 kW
20 kW
2)
20 kW
2)
1.2 kW
2.1 kW
3.8 kW
7.2 kW
11.4 kW
2.6 kW
4.7 kW
8.3 kW
15.6 kW
24.0 kW
2)
5.0 kW
8.5 kW
15.0 kW
24.0 kW
2)
24.0 kW
2)
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
47 10 % 39 10 %
Trip current (of F16) I
F
5 A
RMS
6.5 A
RMS
9.2 A
RMS
5.5 A
RMS
8.1 A
RMS
11.3 A
RMS
Design Wire resistor on ceramic core Grid resistor
Connections /
tightening torque
Ceramic terminals 2.5 mm
2
(AWG13) / 0.5 Nm
BW347-T: Ceramic terminals 10 mm
2
(AWG18) / 1.6 Nm
M8 stud /
6 Nm
Degree of protection IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended) 0055/0075 0110


1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
2) Physical power limit due to DC link voltage and resistance value.
Braking resistor type BW... BW018-015
Part number 821 684 3
Braking resistor type BW...-T/-P BW018-015-P BW018-035-T BW018-075-T BW915-T
Part number 1820 416 3 1820 138 5 1820 139 3 1820 413 9
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
1.5 kW
2.5 kW
4.5 kW
6.7 kW
11.4 kW
3.5 kW
5.9 kW
10.5 kW
15.7 kW
26.6 kW
7.5 kW
12.7 kW
22.5 kW
33.7 kW
52.2 kW
2)
16 kW
27.2 kW
48 kW
62.7 kW
2)
62.7 kW
2)
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
18 10 % 15 10 %
Trip current (of F16) I
F
9.1 A
RMS
13.9 A
RMS
20.4 A
RMS
32.6 A
RMS
Design
Wire resistor on
ceramic core
Grid resistor
Connections /
tightening torque
BW018-015: Ceramic
terminals
2.5 mm
2
(AWG13) /
0.5 Nm
BW018-015-P: Termi-
nal
2.5 mm
2
(AWG13) /
1 Nm
Bolt M8 / 6 Nm
Degree of protection IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended) 0150/0220 and 2 parallel with 0370/0450


3)
0220
1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
2) Physical power limit due to DC link voltage and resistance value.
3) When connected in parallel, the load capacity and trip current are doubled.
P
i
f
kVA
Hz
n
114 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
Braking resistor type BW...- BW012-025
Part number 821 680 0
Braking resistor type BW...-T/-P BW012-025-P BW012-050T BW012-100-T BW106-T BW206-T
Part number 1820 414 7 1820 140 7 1820 141 5 1820 083 4 1820 412 0
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
2.5 kW
4.2 kW
7.5 kW
11.2 kW
19.0 kW
5.0 kW
8.5 kW
15.0 kW
22.5 kW
38.0 kW
10 kW
17 kW
30 kW
45 kW
76 kW
13.5 kW
23 kW
40 kW
61 kW
102 kW
18 kW
30.6 kW
54 kW
81 kW
136.8 kW
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
12 10 % 6 10 %
Trip current (of F16) I
F
14.4 A
RMS
20.4 A
RMS
28.8 A
RMS
47.4 A
RMS
54.7 A
RMS
Design Grid resistor
Connections /
tightening torque
Ceramic terminals 2.5 mm
2
(AWG13) / 0.5 Nm
BW012-025-P: Terminals 4 mm
2
(AWG12) / 1 Nm
Bolt M8 / 6 Nm
Degree of protection IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended) 0300
0370...0750 and 2 parallel with
0900/1100/1320
2)
1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
2) When connected in parallel, the load capacity and trip current are doubled.
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 115
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
Assignment to AC 230 V units (...-2_3)
Technical data of
the braking resis-
tor BW...-T /
BW...-P
Braking resistor type BW... BW039-
003
BW039-
006
BW039-
012
BW027-
006
BW027-
012
Part number 821 687 8 821 688 6 821 689 4 822 422 6 822 423 4
Braking resistor type BW...-T BW039-
012-T
BW039-
026-T
BW018-
015-P
BW018-
035-T
Part number 1820 136 9 1820 415 5 1820 416 3 1820 138 5
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
0.3 kW
0.5 kW
1.0 kW
1.8 kW
2.8 kW
0.6 kW
1.1 kW
1.9 kW
3.6 kW
5.7 kW
1.2 kW
2.1 kW
3.8 kW
6.0 kW
2)
6.0 kW
2)
2) Physical power limit due to DC link voltage and resistance value.
2.6 kW
4.6 kW
6.0 kW
2)
6.0 kW
2)
6.0 kW
2)
0.6 kW
1.1 kW
1.9 kW
3.6 kW
5.7 kW
1.2 kW
2.1 kW
3.8 kW
7.2 kW
8.7 kW
2)
1.5 kW
2.5 kW
4.5 kW
6.7 kW
11.4 kW
3.5 kW
5.9 kW
10.5 kW
13.0 kW
2)
13.0 kW
2)
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
39 10 % 27 10 % 18 10 %
Trip current (of F16) I
F
2.7 A
RMS
3.9 A
RMS
5.5 A
RMS
8.1 A
RMS
4.7 A
RMS
6.6 A
RMS
9.1 A
RMS
13.9 A
RMS
Design Wire resistor Grid resistor
Connections /
tightening torque
Ceramic terminals 2.5 mm
2
(AWG12) /
0.5 Nm
M8 stud /
6 Nm
Degree of protection IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended) 0015/0022 0015...0037 2 parallel with 0110


3)
3) When connected in parallel, the load capacity and trip current are doubled.
Braking resistor type BW...-T/-P BW018-075-T BW915-T BW012-025-P BW012-050-T BW012-100-T BW106-T BW206-T
Part number 1820 139 3 1820 413 9 1820 414 7 1820 140 7 1820141 5 1820 083 4 1820 412 0
Continuous braking power
(= 100% cdf)
Load capacity 50 % cdf
1)
at 25 % cdf
12 % cdf
6 % cdf
7.5 kW
12.7 kW
13.0 kW
2)
13.0 kW
2)
13.0 kW
2)
15.6 kW
2)
15.6 kW
2)
15.6 kW
2)
15.6 kW
2)
15.6 kW
2)
2.5 kW
4.2 kW
7.5 kW
11.2 kW
19.0 kW
5.0 kW
8.5 kW
15.0 kW
19.6 kW
2)
19.6 kW
2)
10 kW
17 kW
19.6 kW
2)
19.6 kW
2)
19.6 kW
2)
13.5 kW
23 kW
39.2 kW
2)
39.2 kW
2)
39.2 kW
2)
18 kW
30.6 kW
39.2 kW
2)
39.2 kW
2)
39.2 kW
2)
Observe regenerative power limit of the inverter!
(= 150 % of the recommended motor power technical data)
Resistance value R
BW
18 10 %
15
10 %
12 10 % 6 10 %
Trip current (of F16) I
F
20.4 A
RMS
32.6 A
RMS
14.4 A
RMS
20.4 A
RMS
28.8 A
RMS
47.4 A
RMS
54.7 A
RMS
Design Grid resistor
Connections /
tightening torque
M8 stud /
6 Nm
Degree of protection IP20 (when installed)
Ambient temperature
U
20 ... +40 C
Type of cooling KS = Self-cooling
For MOVIDRIVE

(recommended) 2 parallel with 0110


3)
0055/0075
0150 and 2 parallel
with 0220/0300
3)
1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration T
D
120 s.
2) Physical power limit due to DC link voltage and resistance value.
3) When connected in parallel, the load capacity and trip current are doubled.
BW...-T / BW...-P
Connection cross section for signal contact 1 x 2.5 mm
2
Switching capability of the thermostats signal contact DC 2 A / DC 24 V (DC11)
AC 2 A / AC 230V (AC11)
Switch contact (NC) according to EN 61800-5-1
P
i
f
kVA
Hz
n
116 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
MDimension drawing braking resistors BW... / BW...-T / BW...-P
60021BXX
BW... :
1 = Flat design
The connecting lead is
500 mm (19.7 in) long.
The scope of delivery
includes four M4 stud
bolts each of type 1 and
2.
2 = Grid resistor
3 = Wire resistor
4 = Wire resistor with
temperature switch
(-T/-P)
Cable entry (X) is
possible from both sides.
Type BW... Mounting
position
Main dimensions mm (in) Fastening parts mm (in) Cable gland Weight
kg (lb)
BW..-T/ BW...-P A/A B C a b/c d
BW106-T 2 795 (31.3) 270 (10.6) 490 (19.3) 770(30.3) 380 (15) 10.5 (0.41) - 32 (71)
BW206-T 2 995 (39.2) 270 (10.6) 490 (19.3) 970 (38.2) 380 (15) 10.5 (0.41) - 40 (88)
BW012-025 2 295 (11.6) 260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18)
BW012-025-P 2
295/355
(11.6)/(14)
260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18)
BW012-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26)
BW012-100-T 2 595 (23.4) 270 (10.6) 490 (19.3) 570 (22.4) 380 (15) 10.5 (0.41) - 21 (46)
BW915-T 2 795 (31.3) 270 (10.6) 490 (19.3) 770 (30.3) 380 (15) 10.5 (0.41) - 30 (66)
BW018-015 3 620 (24.4) 120 (4.72) 92 (3.6) 544 (21.4) 64 (2.5) 6.5 (0.26) PG11 4.0 (8.8)
BW018-015-P 4 649 (25.6) 120 (4.72) 185 (7.28) 530 (20.9) 150 (5.91) 6.5 (0.26) M12 + M25 5.8 (13)
BW018-035-T 2 295 (11.6) 270 (10.6) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) - 9.0 (20)
BW018-075-T 2 595 (23.4) 270 (10.6) 490 (19.3) 570 (22.4) 380 (15) 10.5 (0.41) - 18.5 (40.8)
BW027-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)
BW027-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5)
BW039-003 3 286 (11.3) 120 (4.72) 92 (3.6) 230 (9.06) 64 (2.5) 6.5 (0.26) PG11 1.5 (3.3)
BW039-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)
BW039-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5)
BW039-012-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)
BW039-026-T 4 649 (25.6) 120 (4.72) 275 (10.8) 530 (20.9) 240 (9.45) 6.5 (0.26) M12 + M25 7.5 (17)
BW039-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26)
BW147 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5)
BW147-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)
BW247 3 665 (26.2) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) PG13.5 6.1 (13)
BW247-T 4 749 (29.5) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) M12 + M25 9.2 (20)
BW347 3 670 (26.4) 145 (5.71) 340 (13.4) 630 (24.8) 300 (11.8) 6.5 (0.26) PG13.5 13.2 (29.1)
BW347-T 4 749 (29.5) 210 (8.27) 185 (7.28) 630 (24.8) 150 (5.91) 6.5 (0.26) M12 + M25 12.4 (27.3)
BW168 3 365 (14.4) 120 4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) PG13.5 3.5 (7.7)
BW168-T 4 449 (17.7) 120 (4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) M12 + M25 3.6 (7.9)
BW268 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5)
BW268-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)
BW072-003 1 110 (4.33) 80 (3.1) 15 (0.59) 98 (3.9) 60 (2.4) - 0.3 (0.7)
BW072-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) - 0.6 (1)
BW100-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) - 0.6 (1)
BW100-006 4 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)
BW100-006-T 4 549 (21.6) 120 (4.72) 92 (3.6) 430 (16.9) 80 (3.1) 6.5 (0.26) M12 + M25 3.0 (6.6)
b
10
12
1 2
M
4
4
3
C B
A
2
a 10
d
c
A C
B
a c
d
B
C A
A
'
A
a
M25
M12 C
X
c
8
B
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 117
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
Touch guard BS... A BS.. touch guard is available for braking resistors in flat design.
Dimensions
drawing for BS...
Mounting rail
installation
A mounting rail attachment HS001 is available from SEW-EURODRIVE, part number
822 194 4, for mounting the touch guard on a mounting rail.
Touch guard BS003 BS005
Part number 813 151 1 813 152 X
for braking resistor BW027-003
BW072-003
BW027-005
BW072-005
BW100-005
05247AXX
Figure 26: Dimension drawing, BS touch guard with grommet [1] and support rail mounting [2]
Type Main dimensions mm (in) Mounting dimensions mm (in) Weight kg (lb)
A B C b d e a x
BS-003 60 (2.4) 160 (6.3) 146 (5.75) 125 (4.92) 40 (1.6) 20 (0.79) 6 (0.2) 17.5 (0.69) 0.35 (0.77)
BS-005 60 (2.4) 160 (6.3) 252 (9.92) 125 (4.92) 4 (1.6) 20 (0.79) 6 (0.2) 17.5 (0.69) 0.5 (1)
P
i
f
kVA
Hz
n
118 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Braking resistor type BW... option / BW...-T / BW...-P
Technical Data and Dimension Sheets
DKB11A heat sink for braking resistors in flat design
Part number 814 345 5
Description The DKB11A heat sink for braking resistors in flat design provides a space-saving
means for mounting the braking resistors (BW072-005, BW100-005) beneath
MOVIDRIVE

size 1 units (400/500 V units: 0015...0040; 230 V units: 0015...0037). The


resistor is inserted into the heat sink and attached using the supplied screws (M4 20).
Dimension drawing
[1] Mounting surface for the braking resistor
[2] Retaining screws are not included in the delivery scope
62085AEN
Figure 27: Dimensions, DKB11A heat sink for brake resistors in flatpack design, all in mm (in)
3
0
0

(
1
1
.
8
)
3
1
5

(
1
2
.
4
)
7
2
.
5

(
2
.
8
5
)
1
7
0
.
5

(
6
.
7
1
)
2
7
6
.
5

(
1
0
.
8
9
)
85 (3.3) 10 (0.39)
105 (4.13)
3
4
4

(
1
3
.
5
)
262.5 (10.33)
30
(1.2)
9 (0.4)
4 x spacer bolts
PE screw M5
4 x pan head screws
4 x M5 x 12
4 x M5 x 12 [2]
[1]
BW...005
BW...003
[2] 4 x M5 x 12
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 119
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Line choke option type ND..
Technical Data and Dimension Sheets
2.44 Line choke option type ND..
To increase overvoltage protection.
To limit the charging current when several inverters are connected together in
parallel on the input end with shared mains contactors (rated current of line choke =
total of inverter currents).
ND.. line filters have cRUus approval independent of the MOVIDRIVE

inverters.
Dimension
drawings for ND...
Line choke type ND020-013 ND030-023
1)
ND045-013 ND085-013 ND150-013 ND200-
0033
ND300-0053
Part number 826 012 5 827 151 8 826 013 3 826 014 1 825 548 2 826 579 8 827 721 4
Rated power supply
voltage V
supply
(according to EN 50160)
3 AC 380 V - 500 V, 50/60 Hz
Rated current
2)
I
N
AC 20 A AC 30 A AC 45 A AC 85 A AC 150 A AC 200 A AC 300 A
Power loss at bei I
N
P
V
10 W 30 W 15 W 25 W 65 W 100 W 280 W
Inductance L
N
0.1 mH 0.2 mH 0.1 mH 0.1 mH 0.1 mH 0.03 mH 0.05 mH
Ambient temperature
U
25 ... +45 C
Degree of protection IP 00 (EN 60529)
Connections
Terminal strips
4 mm
2
(AWG12)
Terminal strips
2.5 mm
2
... 10 mm
2

(AWG13 ... AWG8)
Terminal
strips
10 mm
2

(AWG8)
Terminal strips
35 mm
2

(AWG2)
M10 stud
PE: M8 stud
M12 stud
PE: 2 M10
Tightening torque 0.6 ... 0.8 Nm max. 2.5 Nm 3.2 ... 3.7 Nm M10 stud: 10 Nm
PE: 6 Nm
M12 stud:
15.5 Nm
PE: 10 Nm
Assignment to AC 400/500 V units (MDX60/61B...-5_3)
Rated operation (100 %) 0005...0075 0110...0220
0300...0450
and
MDR60A0370
0550/0750
MDR60A
0750
0900...1320
Increased power (125 %) 0005...0075 0110/0150 0220...0370 0450...0750
Assignment to 230 V units (MDX61B...-2_3)
Rated operation (100 %) 0015...0055 - 0075/0110 0150/0220 0300 - -
Increased power (125 %) 0015...0037 - 0055/0075 0110/0150 0220/0300 - -
1) Use ND030-023 for DC link connection without regenerative power supply unit in connection type A or B (see system manual
MOVIDRIVE

MDR60A regenerative power supply).


2) If more than one MOVIDRIVE

is connected to a line choke, the total value of the rated currents of the connected units must not
exceed the rated current of the line choke!
58699AXX
Figure 28: Dimension drawing for line chokes ND020.. / ND030.. / ND045.. / ND085..
[1] Space for installation terminals Input: 1U1, 1V1, 1W1
Any mounting position Output: 1U2, 1V2, 1W2
a
c
c
C
A
[1]
[1]
1U1 1U2 1V1 1V2 1W1 1W2
B
b
P
i
f
kVA
Hz
n
120 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Line choke option type ND..
Technical Data and Dimension Sheets
58315AXX
Figure 29: Dimension drawing for line chokes ND150.. / ND200.. / ND300..
B
a
c c
b
C
A
Line choke
type
Main dimensions mm (in) Mounting dimensions mm (in)
Hole dimension
mm (in)
Weight
A B C a b c kg (lb)
ND020-013 85 (3.3) 60 (2.4) 120 (4.72) 50 (2) 31 - 42 (1.2 - 1.7) 5 - 10 (0.2 - 0.39) 0.5 (1)
ND030-023
ND045-013
125 (4.92) 95 (3.7) 170 (6.69) 84 (3.3) 55-75 (2.2 - 3) 6 (0.24) 2.5 (5.5)
ND085-013 185 (7.28) 115 (4.53) 235 (9.25) 136 (5.35) 56 - 88 (2.2 - 3.5) 7 (0.28) 8 (18)
ND150-013 255 (10) 140 (5.51) 230 (9.06) 170 (6.69) 77 (3) 8 (0.31) 17 (37)
ND200-0033 250 (9.84) 160 (6.3) 230 (9.06) 180 (7.09) 98 (3.9) 8 (0.31) 15 (33)
ND300-0053 300 (11.8) 190 (7.48) 295 (11.6) 255 (10) 145 (5.71) 11 (0.43) 35 (77)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 121
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Line filter type NF...-... option
Technical Data and Dimension Sheets
2.45 Line filter type NF...-... option
To suppress interference emission on the line side of inverters.
Do not switch between the NF... line filter and MOVIDRIVE

.
NF.. line filters have cRUus approval independent of the MOVIDRIVE

inverters.
Line filter type NF009-503 NF014-503 NF018-503 NF035-503 NF048-503
Part number 827 412 6 827 116 X 827 413 4 827 128 3 827 117 8
Rated mains voltage V
N
(according to EN 50160)
3 AC 380 V - 500 V, 50/60 Hz
Rated current I
N
AC 9 A AC 14 A AC 18 A AC 35 A AC 48 A
Power loss at bei I
N
P
V
6 W 9 W 12 W 15 W 22 W
Earth-leakage current at V
N
< 25 mA < 25 mA < 25 mA < 25 mA < 40 mA
Ambient temperature
U
25 ... +40 C
Degree of protection IP20 (EN 60529)
Connections L1-L3/L1-L3
Tightening torque L1-L3/L1-L3
Connection PE
Tightening torque PE
4 mm
2
(AWG 10)
0.8 Nm
M5 stud
3.4 Nm
10 mm
2
(AWG 8)
1.8 Nm
M5 stud
3.4 Nm
10 mm
2
(AWG 8)
1.8 Nm
M6 stud
5.5 Nm
Assignment to AC 400/500 V units (MDX60/61B...-5_3)
Rated operation (100 %) 0005...0040 0055/0075 - 0110/0150 0220
Increased power (125 %) 0005...0030 0040/0055 0075 0110 0150
Assignment to 230 V units (MDX61B...-2_3)
Rated operation (100 %) 0015/0022 0037 - 0055/0075 0110
Increased power (125 %) 0015 0022 0037 0055/0075 -
Line filter type NF063-503 NF085-503 NF115-503 NF150-503 NF210-503 NF300-503
Part number 827 414 2 827 415 0 827 416 9 827 417 7 827 418 5 827 419 3
Rated mains voltage V
N
(according to EN 50160)
3 AC 380 V - 500 V, 50/60 Hz
Rated current I
N
AC 63 A AC 85 A AC 115 A AC 150 A AC 210 A AC 300 A
Power loss at I
N
P
V
30 W 35 W 60 W 90 W 150 W 180 W
Earth-leakage current at V
N
< 30 mA < 30 mA < 30 mA < 30 mA < 40 mA < 45 mA
Ambient temperature
U
25 ... +40 C
Degree of protection IP20 (EN 60529)
Connections L1-L3/L1-L3
Tightening torque L1-L3/L1-L3
Connection PE
Tightening torque PE
16 mm
2
(AWG 6)
3 Nm
M6
5.5 Nm
35 mm
2
(AWG 2)
3.7 Nm
M8
12.8 Nm
50 mm
2
(AWG1/0)
3.7 Nm
M10
23.8 Nm
50 mm
2
(AWG1/0)
3.7 Nm
M10
23.8 Nm
95 mm
2
(AWG4/0)
20 Nm
M10
23.8 Nm
150 mm
2
(AWG300-2)
30 Nm
M12
36 Nm
Assignment to AC 400/500 V units (MDX60/61B...-5_3)
Rated operation (100 %) 0300 0370/0450 0550 0750 0900/1100 1320
Increased power (125 %) 0220 0300/0370 0450 0550/0750 0900 1100/1320
Assignment to 230 V units (MDX61B...-2_3)
Rated operation (100 %) 0150 0220 0300 - - -
Increased power (125 %) 0110/0150 - 0220/0300 - - -
P
i
f
kVA
Hz
n
122 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Line filter type NF...-... option
Technical Data and Dimension Sheets
Dimension draw-
ing for NF...
Any mounting position
55862ADE
Figure 30: Dimension drawing for NF line filter
A
C
a
B
b
C
L3 L2 L1
L3' L2' L1'
Ausgang
Eingang
Line filter
type
Main dimensions mm (in)
Mounting dimensions mm
(in)
Hole dimension
mm (in)
PE
connection
Weight
A B C a b c kg (lb)
NF009-503
55 (2.2)
195 (7.68)
80 (3.1) 20 (0.78)
180 (7.09)
5.5 (0.22)
M5
0.8 (2)
NF014-503 225 (8.86) 210 (8.27) 0.9 (2)
NF018-503 50 (1.97) 255 (10) 240 (9.45) 1.1 (2.4)
NF035-503
60 (2.36)
275 (10.8)
100 (3.94)
30 (1.18)
255 (10) 1.7 (3.7)
NF048-503 315 (12.4) 295 (11.6)
M6
2.1 (4.6)
NF063-503
90 (3.54)
260 (10.2)
60 (2.36)
235 (9.25)
6.5 (0.26)
2.4 (5.3)
NF085-503 320 (12.6) 140 (5.51)
255 (10)
M8 3.5 (7.7)
NF115-503
100 (3.94) 330 (13) 155 (6.1) 65 (2.56)
M10
4.8 (11)
NF150-503 5.6 (12.3)
NF210-503 140 (5.51) 450 (17.7) 190 (7.48) 102 (4.02) 365 (14.4) 8.9 (20)
NF300-503 170 (6.69) 540 (21.3) 230 (9.06) 125 (4.92) 435 (17.1) M12 12.2 (26.9)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 123
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
HD... output choke option
Technical Data and Dimension Sheets
2.46 HD... output choke option
For suppression of interference from the unshielded motor cable. For HD001 to
HD003 we recommend routing the motor cable through the output choke with 5
loops. Only 5 loops are possible if the cable has a large diameter. To make up for
this, 2 or 3 output chokes should be connected in series. Connect in series two output
chokes in case of 4 windings and three output chokes in case of 3 windings.
Output chokes HD001 to HD003 are allocated using the cable cross sections of the
motor feeders. Consequently, there is no separate assignment table for the
AC 230 V units.
The HD004 output choke is assigned to size 6 units (0900... 1320).
Dimension
drawing for HD
Output choke type HD001
1)
HD002
1)
HD003 output
choke
1)
HD004
2)
Part number 813 325 5 813 557 6 813 558 4 816 885 7
Max. power loss P
Vmax
15 W 8 W 30 W 100 W
For cable cross
sections/connections/
tightening torque
1.5...16 mm
2
(AWG 16...6) 1.5 mm
2
(AWG 16) 16 mm
2
(AWG 6)
M12 terminal stud
20 Nm
Degree of protection - - - IP10
1) The output choke type HD... is not a UL/cUL-relevant component.
2) UL/cUL approval is not available for the HD0044 output choke
58419AXX
d
a
b c
C
A
B
HD001
HD002
HD003
P
i
f
kVA
Hz
n
124 System Manual MOVIDRIVE MDX60B/61B Inverter
2
HD... output choke option
Technical Data and Dimension Sheets
58424AXX
MOVIDRIVE

B
120
150
370
400
3
5
9
1
9
6
9
2
M
~
HD004
Output
choke type
Main dimensions mm (in)
Mounting dimensions mm
(in)
Inside mm (in)
Hole dimen-
sion mm (in)
Weight
A B C a b d c kg (lb)
HD001 121 (4.76) 64 (2.5) 131 (5.16) 80 (3.1) 50 (2.0) 50 (2.0)
5.8 (0.23)
0.5 (1)
HD002 66 (2.6) 49 (1.9) 73 (2.9) 44 (1.7) 38 (1.5) 23 (0.91) 0.2 (0.4)
HD003 170 (6.69) 64 (2.5) 185 (7.28) 120 (4.72) 50 (2.0) 88 (3.5) 7.0 (0.28) 1.1 (2.4)
HD004 150 (5.91) 400 (15.7) 360 (14.2) 120 (4.72) 370 (14.6) - 9.0 (0.35) 12.5 (27.6)
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 125
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Output filter option type HF...
Technical Data and Dimension Sheets
2.47 Output filter option type HF...
HF... output filters are sine filters used to smooth output voltage from inverters. HF...
output filters (with the exception of HF450-503) are approved to UL/cUL in combination
with MOVIDRIVE

inverters. HF... output filters are used in the following cases:


In group drives (several motor leads in parallel); the discharge currents in the motor
cables are suppressed.
To protect the motor winding insulation of non-SEW motors which are not suitable for
inverters
for protection against overvoltage spikes in long motor cables (> 100 m)
Please read the following notes carefully:
NOTES
Operate output filters in V/f and VFC operating modes only. Do not use output filters
in CFC and SERVO operating modes.
Do not use output filters in hoist applications.
During project planning of the drive, take into account the voltage drop in the output
filter and consequently the reduced motor torque available. This applies particularly
to AC 230 V units with output filters.
Output filter type HF008-503
1)
HF015-503
1)
HF022-503
1)
HF030-503
1)
HF040-503
1)
HF055-503
1)
Part number 826 029 X 826 030 3 826 031 1 826 032 X 826 311 6 826 312 4
Rated voltage V
N
3 AC 230 V - 500 V, 50/60 Hz
2)
Earth-leakage current at U
N
I 0 mA
Power loss at I
N
P
V
25 W 35 W 55 W 65 W 90 W 115 W
Interference emission via
unshielded motor cable
According to limit value class C1 to EN 61800-3
Ambient temperature
U
0 ... +45 C (reduction: 3 % I
N
per K to max. 60 C)
Degree of protection (EN 60529) IP20
Connections /
tightening torque
M4 terminal stud
1.6 Nm 20 %
Weight 3.1 kg (6.8 lb) 4.4 kg (9.7 lb) 10.8 kg (23.8 lb)
Assignment to AC 400/500 V units (MDX60/61B...-5_3)
Voltage drop at I
N
U < 6.5 % (7.5 %) at AC 400 V / < 4 % (5 %) at AC 500 V and f
Amax
= 50 Hz (60 Hz)
Rated throughput current
3)
I
N 400 V
(at V
supply
= 3 AC 400 V)
Rated throughput current
3)
I
N 500 V
(at V
supply
= 3 AC 500 V)
AC 2.5 A
AC 2 A
AC 4 A
AC 3 A
AC 6 A
AC 5 A
AC 8 A
AC 6 A
AC 10 A
AC 8 A
AC 12 A
AC 10 A
Rated operation (100 %)
3)
0005 ... 0011 0014 / 0015 0022 0030 0040 0055
Increased power (125 %)
3)
0005 0008 / 0011 0014 / 0015 0022 0030 0040
Assignment to 230 V units (MDX61B...-2_3)
Voltage drop at I
N
U - < 18.5 % (19 %) at AC 230 V with f
Amax
= 50 Hz (60 Hz)
Rated throughput current
3)
I
N 230 V
(at V
supply
= 3 AC 230 V)
AC 4.3 A AC 6.5 A AC 10.8 A AC 13 A AC 17.3 A AC 22 A
Rated operation (100 %)
3)
- - 0015/0022 - 0037 0055
Increased power (125 %)
3)
- - 0015/0022 - - 0037
1) Approved to UL/cUL in combination with MOVIDRIVE

inverters. SEW-EURODRIVE will provide a certificate on request.


2) A reduction of 6 % I
N
per 10 Hz applies above f
A
= 60 Hz for the rated through current I
N
.
3) Only applies to operation without V
DC link
connection. For operating the inverter with V
DC link
connection, observe the project planning
notes in the system manual of the respective inverter.
P
i
f
kVA
Hz
n
126 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Output filter option type HF...
Technical Data and Dimension Sheets
Output filter type HF075-503
1)
HF023-403
1)
HF033-403
1)
HF047-403
1)
HF450-503
Part number 826 313 2 825 784 1 825 785 X 825 786 8 826 948 3
Rated voltage V
N
3 AC 230 V - 500 V, 50/60 Hz
2)
Earth-leakage current at U
N
I 0 mA
Power loss at I
N
P
V
135 W 90 W 120 W 200 W 400 W
Interference emission via
unshielded motor cable
According to limit value class C1 to EN 61800-3
Ambient temperature
U
0 ... +45 C (reduction: 3 % I
N
per K to max. 60 C)
Degree of protection (EN 60529) IP 20 IP20 IP 10
Connections /
tightening torque
M4 terminal stud
1.6 Nm 20 %
35 mm
2
(AWG 2)
3.2 Nm
Weight 10.8 kg (23.8 lb) 15.9 kg (35.1 lb) 16.5 kg (36.4 lb) 23 kg (51 lb) 32 kg (71 lb)
Assignment to AC 400/500 V units (MDX60/61B...-5_3)
Voltage drop at I
N
U < 6.5 % (7.5 %) at AC 400 V / < 4 % (5 %) at AC 500 V and f
Amax
= 50 Hz (60 Hz)
Rated throughput current
3)
I
N 400 V
(at V
supply
= 3 AC 400 V)
Rated throughput current
3)
I
N 500 V
(at V
supply
= 3 AC 500 V)
AC 16 A
AC 13 A
AC 23 A
AC 19 A
AC 33 A
AC 26 A
AC 47 A
AC 38 A
AC 90 A
AC 72 A
Rated operation (100 %)
3)
0075 0110 0150/0300
4)
0220
0370/0450/
0550
4)
/0750
4)
/
0900
4)
Increased power (125 %)
3)
0055 0075 0110/0220
4)
0150
0300/0370/0450
4)
/0550
4)
/0750
4)
Assignment to 230 V units (MDX61B...-2_3)
Voltage drop at I
N
U < 18.5 % (19 %) at AC 230 V with f
Amax
= 50 Hz (60 Hz)
Rated throughput current
3)
I
N 230 V
(at V
supply
= 3 AC 230 V)
AC 29 A AC 42 A AC 56.5 A AC 82.6 A AC 156 A
Rated operation (100 %)
3)
0075 0110 0150/0300
4)
0220 0300
Increased power (125 %)
3)
0055 0075 0110/0220
4)
0150 0220/0300
1) Approved to UL/cUL in combination with MOVIDRIVE

inverters. SEW-EURODRIVE will provide a certificate on request.


2) A reduction of 6 % I
N
per 10 Hz applies above f
A
= 60 Hz for the rated through current I
N
.
3) Only applies for operation without V
DC link
connection. For operation with V
Z
connection, observe the project planning instructions in
the MOVIDRIVE

MDX60/61B system manual, section "Project Planning/Connecting the optional power components."
4) Connect two HF... output filters together in parallel for operation with these MOVIDRIVE

units.
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 127
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Output filter option type HF...
Technical Data and Dimension Sheets
Dimension drawings for HF...-503 output filters
HF008 / 015 / 022 / 030-503 HF040/055/075-503
58418AXX
Figure 31: Dimension drawings for output filters HF008...075-503
Only the mounting position shown in the dimension drawing is permitted.
Output filter type
Main dimensions mm (in)
Mounting dimensions
mm (in)
Hole dimen-
sion mm (in)
Ventilation clearances
1)

mm (in)
1) There is no need for clearance at the sides. You can line up the units next to one another.
A B C a b c Top Bottom
HF008/015/022/030-503 80 (3.1) 286 (11.3) 176 (6.93) - 265 (10.4)
7 (0.3) 100 (3.94) 100 (3.94)
HF040/055/075-503 135 (5.31) 296 (11.7) 216 (8.5) 70 (2.8) 283 (11.1)
HF450-503
58417AXX
Figure 32: Dimension drawing for output filter HF450-503
Only the mounting position shown in the dimension drawing is permitted
Output filter
type
Main dimensions mm (in)
Mounting dimensions
mm (in)
Hole dimen-
sion mm (in)
Ventilation clearances
mm (in)
A B C a b c Top Bottom
HF450-503 465 (18.3) 385 (15.2) 240 (9.45) 436 (17.2) 220 (8.66) 8.5 (0.33) 100 (3.94) 100 (3.94)
b b
c a c
C C A A
B B
MOVIDRIVE
MOVIDRIVE

W1
W2
V1
V2
V5
U1
4 5 6 8
U2
MOVIDRIVE
M
~
1
1
1
a
b
B
c
A C
4 5 6 7 U V W
P
i
f
kVA
Hz
n
128 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Output filter option type HF...
Technical Data and Dimension Sheets
Dimension drawing for HF...-403 output filter
58996AXX
Figure 33: Dimension drawing for HF...-403 output filter
Type
Main dimensions mm (in)
Mounting dimensions mm (in)
Hole
dimen-
sion mm
(in)
Ventilation clearances
mm (in)
Standard mounting
position
Horizontal
mounting
position
A B C/C1 a b a1 a2 c
At the
side
Top
Bot-
tom
HF023-403
145
(5.71)
284
(11.2)
365/390
(14.4/15.4)
268
(10.6)
60 (2.4)
210
(8.27)
334
(13.1)
6.5 (0.26)
je 30
(1.2)
150
(5.91)
150
(5.91)
HF033-403
HF047-403
190
(7.48)
300
(11.8)
385/400
(15.2/15.7)
284
(11.2)
80 (3.1)
b
c
a
4
5
6
7
U
V
W
b1
a
1
c
B
A C
C1
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 129
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
2.48 Prefabricated cables
Overview SEW offers cable sets and prefabricated cables for straightforward and error-free
connection of various system components to MOVIDRIVE

. The cables are pre-


fabricated in 1 m steps to the required length. It is necessary to differentiate between
whether the cables are intended for fixed routing or for cable carrier applications.
1. Cable sets for DC link connection MDR MDX
2. Motor cables and extension cables for connecting CM motors
3. Motor cables and extension cables for connecting DS, CMD and CMP motors.
4. VR forced cooling fan cable and extension cable
5. Connection to DEH11B/DEH21B/DER11B: Encoder cable and extensions cable
(Hiperface

, incremental encoder), resolver cable and extension cable in plug and


terminal box design for motors.
1. Cable sets for DC link connection MDR MDX
Description SEW-EURODRIVE strongly recommends using the cable sets listed in the table below.
These cable sets offer the appropriate dielectric strength and are also color-coded.
Color coding is necessary because cross-polarity and ground faults could cause irrepa-
rable damage to the connected equipment.
The length of the cables restricts the DC link connection to the permitted length of 5 m.
They can also be cut to length by the customer for connecting several units. The lugs
for connection to the regenerative power supply unit and an inverter are supplied with
the cable set. Use commercially available cable lugs to connect other inverters. In this
case, connect inverters in star configuration to the regenerative power supply unit. Use
a busbar subdistributor if the DC link terminals of the regenerative power supply unit are
not sufficient.
Installation type Only fixed routing is possible.
Cable set type DCP12A DCP13A DCP15A DCP16A
Part number 814 567 9 814 250 5 814 251 3 817 593 4
For connecting
MOVIDRIVE


0015...0110 0150...0370 0450...0750 0900...1320
P
i
f
kVA
Hz
n
130 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
2. Prefabricated cables and extension cables for connecting CM motors to MDX
Motor cables The cables are equipped with a connector for motor connection and conductor end
sleeves for inverter connection.
Extension cables The cables are equipped with a connector and adapter for extending the CM motor
cable.
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
199 179 5
Fixed installation
CM..SM51
41.5 mm
2
+ 31.0 mm
2
199 189 2 CM..BR SB51
42.5 mm
2
199 181 7 CM..SM52
42.5 mm
2
+ 31.0 mm
2
199 191 4 CM..BR SB52
44 mm
2
199 183 3 CM..SM54
44 mm
2
+ 31.0 mm
2
199 193 0 CM..BR SB54
46 mm
2
199 185 X CM..SM56
46 mm
2
+ 31.5 mm
2
199 195 7 CM..BR SB56
410 mm
2
199 187 6 CM..SM59
410 mm
2
+ 31.5 mm
2
199 197 3 CM..BR SB59
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
1 333 114 0
Cable carrier installation
CM..SM51
41.5 mm
2
+ 31.0 mm
2
1 333 116 7 CM..BR SB51
42.5 mm
2
1 333 115 9 CM..SM52
42.5 mm
2
+ 31.0 mm
2
1 333 117 5 CM..BR SB52
44 mm
2
199 184 1 CM..SM54
44 mm
2
+ 31.0 mm
2
199 194 9 CM..BR SB54
46 mm
2
199 186 8 CM..SM56
46 mm
2
+ 31.5 mm
2
199 196 5 CM..BR SB56
410 mm
2
199 188 4 CM..SM59
410 mm
2
+ 31.5 mm
2
199 198 1 CM..BR SB59
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
199 549 9
Fixed installation
CM..SM51
41.5 mm
2
+ 31.0 mm
2
199 199 X CM..BR SB51
42.5 mm
2
199 551 0 CM..SM52
42.5 mm
2
+ 31.0 mm
2
199 201 5 CM..BR SB52
44 mm
2
199 553 7 CM..SM54
44 mm
2
+ 31.0 mm
2
199 203 1 CM..BR SB54
46 mm
2
199 555 3 CM..SM56
46 mm
2
+ 31.5 mm
2
199 205 8 CM..BR SB56
410 mm
2
199 557 X CM..SM59
410 mm
2
+ 31.5 mm
2
199 207 4 CM..BR SB59
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 131
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
3. Prefabricated cables and extension cables for connecting DS/CMD/CMP motors
Motor cables The cables are equipped with a connector for motor connection and conductor end
sleeves for inverter connection.
Extension cables The cables are equipped with a connector and adapter for extending the motor cable.
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
1 333 118 3
Cable carrier installation
CM..SM51
41.5 mm
2
+ 31.0 mm
2
1 333 120 5 CM..BR SB51
42.5 mm
2
1 333 119 1 CM..SM52
42.5 mm
2
+ 31.0 mm
2
1 333 121 3 CM..BR SB52
44 mm
2
199 554 5 CM..SM54
44 mm
2
+ 31.0 mm
2
199 204 X CM..BR SB54
46 mm
2
199 556 1 CM..SM56
46 mm
2
+ 31.5 mm
2
199 206 6 CM..BR SB56
410 mm
2
199 558 8 CM..SM59
410 mm
2
+ 31.5 mm
2
199 208 2 CM..BR SB59
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
590 454 4
Fixed installation
DS56 / CMD.. / CMP.. SM11
41.5 mm
2
+ 21 mm
2
1 332 485 3 DS56..B / CMD..BP / CMP..BP SB11
42.5 mm
2
590 455 2 DS56 / CMD.. / CMP.. SM12
42.5 mm
2
+ 21 mm
2
1 333 213 9 DS56..B / CMD..BP / CMP..BP SB12
44 mm
2
590 456 0 DS56 / CMD.. / CMP.. SM14
44 mm
2
+ 21 mm
2
1 333 214 7 DS56..B / CMD..BP / CMP..BP SB14
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
590 624 5
Cable carrier installation
DS56 / CMD.. / CMP.. SM11
41.5 mm
2
+ 21 mm
2
1 333 122 1 DS56..B / CMD..BP / CMP..BP SB11
42.5 mm
2
590 625 3 DS56 / CMD.. / CMP.. SM12
42.5 mm
2
+ 21 mm
2
1 333 215 5 DS56..B / CMD..BP / CMP..BP SB12
44 mm
2
590 480 3 DS56 / CMD.. / CMP.. SM14
44 mm
2
+ 21 mm
2
1 333 216 3 DS56..B / CMD..BP / CMP..BP SB14
Number of cores and line cross section Part number Installation type for motor
41.5 mm
2
1 333 245 7
Cable carrier installation
DS56 / CMD.. / CMP.. SM11
41.5 mm
2
+ 21 mm
2
1 333 248 1 DS56..B / CMD..BP / CMP..BP SB11
42.5 mm
2
1 333 246 5 DS56 / CMD.. / CMP.. SM12
42.5 mm
2
+ 21 mm
2
1 333 250 3 DS56..B / CMD..BP / CMP..BP SB12
44 mm
2
1 333 247 3 DS56 / CMD.. / CMP.. SM14
44 mm
2
+ 21 mm
2
1 333 251 1 DS56..B / CMD..BP / CMP..BP SB14
P
i
f
kVA
Hz
n
132 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
4. Prefabricated cables and extension cables for connecting VR forced cooling fans
VR forced cooling fan cable:
Extension cable for the VR forced cooling fan cable:
Number of cores and line cross section Part number Installation type
31 mm
2
198 634 1 Fixed installation
31 mm
2
199 560 X Cable carrier installation
Number of cores and line cross section Part number Installation type
31 mm
2
199 561 8 Fixed installation
31 mm
2
199 562 6 Cable carrier installation
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 133
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
5. Prefabricated cables for connecting options DEH11B / DEH21B / DER11B
The following overviews show the possible connections for the DEH11B/DEH21B and
DER11B options.
Meaning of the
symbols
The connection cables are assigned a part number and a symbol. The symbols have the
following meaning:
Symbol Meaning
56047AXX
Connection cable connector connector for fixed installation
56051AXX
Extension connection cable connector connector for fixed installation
56048AXX
Connection cable connector connector for cable carrier installation
56052AXX
Extension connection cable connector connector for cable carrier installation
56049AXX
Connection cable connector terminal box for fixed installation
56050AXX
Connection cable connector terminal box for cable carrier installation
56053AXX
Connection cable connector Y connector for fixed installation
56054AXX
Connection cable connector Y connector for cable carrier installation
56489AXX
Connection cable connector connector with crossed A/B track for reversing the
direction of rotation (for fixed installation)
56112AXX
Encoder connection via plug connector
56113AXX
Encoder connection via encoder terminal strip
56114AXX
Connection via plug connector on the motor side
56115AXX
Connection via terminal box on the motor side
P
i
f
kVA
Hz
n
134 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Connection options at X15 X15 DEH11B/DEH21B
62907AXX
DEH11B
DEH21B
X
1
4
X
1
5
15
1
8
9
9
8
1
15
ES1S, ES2S, EV1S, EV2S, EH1S
ES1R, ES2R, EV1R, EV2R, EH1R
5
1
9
6
DIP11B
DEH21B
X
6
2

X62 DIP11B
SSI
1332 813 1
1332 812 3
X2 DWI11A
TTL/5V
198 829 8
198 828 X
AV1Y
593 968 2
X15 DEH.1B
TTL Sin/Cos
1332 459 4
1332 458 6
X15 DEH.1B
Sin/Cos
CM
AS1H, ES1H
DS
AS1H, ES1H
X15 DEH.1B
Hiperface

1332 453 5
1332 455 1
Hiperface

199 539 1
199 540 5
X15 DEH.1B
Hiperface

1332 457 8
1332 454 3
X15 DEH.1B
Hiperface

1332 765 8
1332 766 6
1
5
6
9
5
1
9
6
X
2
:

E
n
c
o
d
e
r
X
1
:

M
O
V
I
D
R
I
V
E
DWI11A
X15 DEH.1B
X1 DWI11A
817 957 3
198 828 X
198 829 8
X15 DEH11B
HTL/TTL
188 180 9
HTL
(DWE12B)
DS, CM, CMD, CMP
DT(E)/DV(E), CT/CV, DZ/DX
AF1H, AK0H, AS1H, AS3H, AS4H
EF1H, EK0H, ES1H, ES3H, ES4H EV1H, AV1H
DT(E)/DV(E), eDT/eDV, CT/CV
DR63, DZ/DX
DT(E)/DV(E), eDT/eDV
DR63, DZ/DX
ES1C, ES2C, EV1C
EH1C, EV2C
ES1T, ES2T, EV1T, EV2T,
EH1T
DT(E)/DV(E), eDT/eDV
DR63, DZ/DX
AV1Y
DT(E)/DV(E), CT/CV
DR63, DZ/DX
NOTE
For the individual wiring diagrams, refer to the section "Installation" in the
MOVIDRIVE

MDX60B/61B" operating instructions.


P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 135
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect HIPERFACE

encoders AF1H, AK0H, AS1H, AS3H, AS4H, EF1H,


EK0H, ES1H, ES3H, ES4H, EV1H, AV1H with plug connector connection on the
motor side to DS, CM, CMD, CMP, DT, DV, DT(E), DV(E), CT, CV, DZ or DX motors.
Extension cable to connect HIPERFACE

encoders AF1H, AK0H, AS1H, AS3H,


AS4H, EF1H, EK0H, ES1H, ES3H, ES4H, EV1H, AV1H with plug connector connec-
tion on the motor side to DS, CM, CMD, CMP, DT, DV, DT(E), DV(E), CT, CV, DZ or
DX motors.
Cable to connect HIPERFACE

encoders AS1H, ES1H, AF1H, EF1H with terminal


box connection on the motor side to CM motors.
56135AXX
Type Installation Part number
DEH11B/21B X15
DS/CM/CMD/CMP/DT/DV/DT(E)/DV(E)/CT/CV/DZ/
DX motors with AF1H, AK0H, AS1H, AS3H, AS4H,
EF1H, EK0H, ES1H, ES3H, ES4H, EV1H, AV1H
56047AXX
1332 453 5
56048AXX
1332 455 1
56136AXX
Type Installation Part number
DEH11B/21B X15
DS/CM/CMD/CMP/DT/DV/DT(E)/DV(E)/CT/CV/DZ/
DX motors with AF1H, AK0H, AS1H, AS3H, AS4H,
EF1H, EK0H, ES1H, ES3H, ES4H, EV1H, AV1H
56051AXX
199 539 1
56052AXX
199 540 5
56137AXX
Type Installation Part number
DEH11B/21B X15 CM motors with AS1H, ES1H,
AF1H, EF1H
56049AXX
1332 457 8
56050AXX
1332 454 3
P
i
f
kVA
Hz
n
136 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect HIPERFACE

encoders AS1H, ES1H, AF1H, EF1H with terminal


box connection on the motor side to DS motors.
Cable to connect sin/cos encoders ES1S, ES2S, EV1S, EV2S, EH1S, ES1R, ES2R,
EV1R, EV2R, EH1R with terminal box connection on the motor side to CT, CV,
DT(E), DV(E), eDT, eDV, DR, DZ and DX motors.
56132AXX
Type Installation Part number
DEH11B/21B X15 DS motors with AS1H, ES1H,
AF1H, EF1H
56049AXX
1332 765 8
56050AXX
1332 766 6
56132AXX
Type Installation Part number
DEH11B/21B X15
DT(E)/DV(E)/eDT/eDV/CT/CV/DR/DZ/DX motors
with sin/cos encoders ES1S, ES2S, EV1S, EV2S,
EH1S, ES1R, ES2R, EV1R, EV2R, EH1R
56049AXX
1332 459 4
56050AXX
1332 458 6
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 137
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Cable (option DWE12B, interface adapter HTL TTL) to connect push-pull HTL
encoders at X15 of option ( chapter "Interface adapter DWE11B/12B").
Cable to connect push-pull HTL encoders ES1C, ES2C, EV1C, EV2C, EH1C with
terminal box connection on the motor side to DT(E), DV(E), eDT, eDV, DR, DZ and
DX motors.
59109AXX
Type Installation Part number
DEH11B/21B X15 Option DWE12B (connection
for push-pull HTL encoders)
56047AXX
188 180 9
56132AXX
Type Installation Part number
Push-pull HTL encoders ES1C, ES2C, EV1C,
EV2C, EH1C DT(E)/DV(E)/eDT/eDV/DR/DZ/DX
motors
56049AXX
198 829 8
56050AXX
198 828 X
P
i
f
kVA
Hz
n
138 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect DC 5 V TTL sensors ES1T, ES2T, EV1T, EV2T, EH1T with terminal
box connection on the motor side (DT(E), DV(E), eDT, eDV, DR, DZ or DX motors)
to DC 5 V encoder power supply type DWI11A.
Cable to connect the DC 5 V encoder power supply type DWI11A via plug connector.
56132AXX
Type Installation Part number
DC 5 V TTL sensors ES1T, ES2T, EV1T, EV2T,
EH1T DWI11A X2
56049AXX
198 829 8
56050AXX
198 828 X
56109AXX
Type Installation Part number
DEH11B/21B X15 DWI11A X1
56047AXX
817 957 3
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 139
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Y cable to connect the AV1Y absolute encoder with plug connector on the motor side
to DT(E), DV(E), CT, CV, DR, DZ and DX motors. The following encoder tracks are
evaluated with the Y cable:
SSI track of the AV1Y absolute encoder and at DIP11B/DEH21B X62
sin/cos track of the AV1Y absolute encoder at DEH11B X15
Extension cable to connect the AV1Y absolute encoder with plug connector on the
motor side to DT(E), DV(E), CT, CV, DR, DZ und DX motors.
59321AXX
Type Installation Part number
DEH11B X15 AV1Y and DIP11B/DEH21B X62
56053AXX
1332 813 1
56054AXX
1332 812 3
56131AXX
Type Installation Part number
DT(E)/DV(E)/CT/CV/DR/DZ/DX motors AV1Y
56052AXX
593 968 2
P
i
f
kVA
Hz
n
140 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Connection options at X14, DEH11B / DER11B
Cable to connect external HIPERFACE

encoders AV1H, AS1H, ES1H, AF1H,


EF1H via plug connector.
63294AXX
NOTE
For the individual wiring diagrams, refer to the section "Installation" in the
MOVIDRIVE

MDX60B/61B" operating instructions.


DEH11B
X
1
4
15
1
8
9
X14 DER11B/DEH11B
X42 DRS11B
818 166 7
818 167 5 1
5
6
9
1
5
6
9
DRS11B
X
4
3

5
1
9
6
5
1
9
6
X
4
2
AV1H EV1S, EV1R EV1T
X
2
:

E
n
c
o
d
e
r
X
1
:

M
O
V
I
D
R
I
V
E
DWI11A
DER11B
X
1
4
15
1
8
9
X14 DER11B/
DEH11B
Hiperface

818 015 6
818 165 9
X14 DER11B/DEH11B
TTL, Sin/Cos
817 960 3
818 168 3
X14 DER11B/DEH11B
X1 DWI11A
818 164 0
X14 DER11B/DEH11B
X14 DEH11B
X14 DER11B
817 958 1
X2 DWI11A
TTL/5V
198 829 8
198 828 X
Hiperface

199 539 1
199 540 5
DER11B
DEH11B
X
1
5
9
8
1
15
56130AXX
Type Installation Part number
DEH11B / DER11B X14 AV1H, AS1H, ES1H,
AF1H, EF1H
56047AXX
818 015 6
56048AXX
818 165 9
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 141
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect external HIPERFACE

encoders AV1H, AS1H, ES1H, AF1H,


EF1H via plug connector.
Cable to connect external Hiperface

encoders via encoder terminal strip.


Cable to connect external sin/cos encoders via encoder terminal strip.
56131AXX
Type Installation Part number
DEH11B / DER11B X14 AV1H, AS1H, ES1H,
AF1H, EF1H
56051AXX
199 539 1
56052AXX
199 540 5
56132AXX
Type Installation Part number
DEH11B / DER11B X14 Hiperface

encoders
56049AXX
1810 695 1
56050AXX
1810 697 8
56132AXX
Type Installation Part number
DEH11B / DER11B X14 sin/cos encoders
56049AXX
819 869 1
56050AXX
818 168 3
P
i
f
kVA
Hz
n
142 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect the DC 5 V encoder power supply type DWI11A via plug connector.
Cable to connect an external DC 5 V TTL sensor to the DC 5 V encoder power supply
type DWI11A via encoder terminal strip.
Cable to connect a master/slave connection.
56109AXX
Type Installation Part number
DEH11B / DER11B X14 DWI11A X1
56047AXX
818 164 0
56132AXX
Type Installation Part number
DC 5 V TTL sensor DWI11A X2
56049AXX
198 829 8
56050AXX
198 828 X
56109AXX
Type Installation Part number
DEH11B/DER11B X14 DER11B/DEH11B X14
56047AXX
817 958 1
P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 143
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect the encoder simulation (DEH11B/DER11B:X14) of the master to
terminal X42 of option DRS11B.
56109AXX
Type Installation Part number
DEH11B/DER11B X14 DRS11B X42
(master and slave turn in the same direction)
56047AXX
0818 166 7
DEH11B/DER11B X14 DRS11B X42
(master and slave turn in opposite directions)
56489AXX
0818 167 5
P
i
f
kVA
Hz
n
144 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Connection options at X15 DER11B
56483BXX
AV1Y
DS, CM, CMD, CMP
RH1M, RH1L
CM
RH1M, RH1L
DS
RH1M, RH1L
DS, CM
RH1M, RH1L
5
1
9
6
DIP11B
X
6
2

X15 DER11B
RH1M/L
199 487 5
199 319 4
RH1M/L
199 542 1
199 541 3
X62 DIP11B
SSI
198 929 4
198 930 8
X15 DER11B
RH1M/L
199 589 8
199 590 1
X15 DER11B
RH1M/L
1332 817 4
1332 844 1
DER11B
X
1
4
X
1
5
15
1
8
9
6
5
1
9
NOTE
For the individual wiring diagrams, refer to the section "Installation" in the
MOVIDRIVE

MDX60B/61B" operating instructions.


P
i
f
kVA
Hz
n
System Manual MOVIDRIVE MDX60B/61B Inverter 145
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect resolvers RH1M / RH1L with plug connector connection on the
motor side to DS, CM, CMD or CMP motors.
Extension cable to connect resolvers RH1M / RH1L with plug connector connection
on the motor side to DS, CM, CMD or CMP motors.
56138AXX
Type Installation Part number
DER11B X15 DS/CM/CMD/CMP motors with
RH1M/RH1L
56047AXX
199 487 5
56048AXX
199 319 4
56139AXX
Type Installation Part number
DER11B X15 DS/CM/CMD/CMP motors with
RH1M/RH1L
56051AXX
199 542 1
56052AXX
199 541 3
P
i
f
kVA
Hz
n
146 System Manual MOVIDRIVE MDX60B/61B Inverter
2
Prefabricated cables
Technical Data and Dimension Sheets
Cable to connect resolvers RH1M / RH1L with terminal box connection on the motor
side to CM and DS motors.
CM and DS motors with integrated resolver: Additional cable to connect the AV1Y
absolute encoder with plug connector connection on the motor side to DIP11B X62.
56142AXX
Type Installation Part number
DER11B X15 CM motors with RH1M/RH1L
56049AXX
199 589 8
56050AXX
199 590 1
DER11B X15 DS motors with RH1M/RH1L
56049AXX
1332 817 4
56050AXX
1332 844 1
56143AXX
Type Installation Part number
DS/CM motors with AV1Y DIP11B X62
56047AXX
198 929 4
56048AXX
198 930 8
P
i
f
kVA
Hz
n

You might also like