PI - OMD 41 - en - D05-04 - 8007228
PI - OMD 41 - en - D05-04 - 8007228
PI - OMD 41 - en - D05-04 - 8007228
The Requirement
With the OMD 41 SICK-MAIHAK offers an Opacity and Dust Concentration Monitor based on the auto-collimation principle to meet highest standards. Due to its TUVapproval the OMD 41 is suitable for applications according to the Federal German Pollution Control Act and the 13th Implementation Ordinance. Furthermore designed to comply with international regulations it completely fullfills international standards for example GOST, by measuring dust emissions and monitoring opacity with high reliability.
One of the remarkable features of both OMD 41 models is the automatic zero-point and the span check cycle. An additional integrated linearity measurement features 4 measuring points. A contamination measurement and correction is performed for the optical surfaces of both transceiver and the reflector unit.
Key Features
LC measurement display (opac-
available
Remote diagnostics via modem
Application Areas
Power plants, cement plants, Glass, steel and paper industry Electrostatic precipitator control/
possible
Automatic contamination correc-
regulation
Special applications (thick channel
ity check
The Technology
The optical and electronic functional elements are contained within the transceiver unit. A pulsed LED with a long lifetime serves as the light source. An integral sighting device eases alignment of the transceiver and the reflector units. In order to protect the optical surfaces from dust and high temperature the transceiver and reflector unit are purged with air. The connection unit contains the display and operating elements and all connections. The OMD 41 can be controlled via:
connection unit directly MEPA OMD 41 on a PC RCU-MS remote control Reflector unit Transceiver unit (TR unit) Connection unit RCU-MS
2m
Modem
The parameters of the OMD 41 can be easily set via modem. The Principle The OMD 41 is a transmissiometer based on a precise optical system. A con-
centrated light beam is directed through the dustladen medium in the duct to the reflector and returned to the receiver. The receiver compares the intensities of the returned light with the transmitted
unit.
Technical Data Measuring Data Measuring principle Measuring range
light and determines transmission or opacity. The extinction value is calculated from these to obtain a linear relation with dust concentration. Display of transmission, opacity or extinction values are selected on the connection unit.
OMD 41 Transmission in auto collimation; light passes through measuring path twice OMD 41-02 1000 %/10050 % 0100 %/050 % 02/00.3 max. 04,000 mg/m3 2 % fullscale 1600 s, in stages from 1 s freely selectable 0.515 m above dewpoint up to 600 C / 1,112 F 20+55 C / 4+130 F max. +10 hPa / +4 inwc with standard purge-air unit; max. 40 hPa / +16 inwc with stronger fan2) Transceiver Unit IP 65 / NEMA 4X 205 x 270 x 375,5 mm3 8 x 10.3 x 14.7 in
3
Accuracy Response time Plant Data Measuring path Meas. gas temperature Ambient temperature Meas. gas pressure Device Data Class of protection Power supply Dimensions (W x H x D) Weight Purge air unit Compliance Interfaces and Signals Interface Signals
1)
Reflector Unit
Connection Unit
8 007 228/05-2004 DIV03/SM Printed in Germany (05-2004) . Subject to change without prior notice
90260 V AC, 4862 Hz; 200 W power consumption (connection unit) 205 x 270 x 250,5 mm3 8 x 10.3 x 10 in 8 kg / 17 lb
3
12 kg /47 lb
Refer to data sheet, order nor. 8 008 088 CE, TV (German Technical Inspection), Clean Air Act (13th Impl. Ord.), GOST, U.S. EPA incl. PS1 RS 232 service interface; RS 422 for optional RCU-MS remote control unit 0/2/420 mA; 750 max. load, electrically isolated 48 V DC, 1 A, 30 W max.; 48 V AC, 1 A; Cycle/maintenance, limit value 1 and 2, malfunction 1025 V AC/1035 V DC: foating contact (electrically isolated)
2)
On request
SICK MAIHAK GmbH Analyzers and Process Instrumentation Nimburger Str. 11 79276 Reute Germany Phone +49 7641 469-0 Fax +49 7641 469 11 49 www.sick-maihak.com E-Mail: [email protected]