This document provides specifications and instructions for an LMG-SS12A64 serial dot matrix liquid crystal display module. It includes details on the mechanical dimensions, interface pin connections, electrical characteristics, and operating instructions. Key points include that it has a 128x64 dot matrix display, requires a DC 5V power supply, has interface pins for data/instruction input and output, and can be operated through instructions to turn on/off, set the display start line and page, write and read display data, and read the status.

Uploaded by

henrickramalho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views9 pages

LCD12A64

This document provides specifications and instructions for an LMG-SS12A64 serial dot matrix liquid crystal display module. It includes details on the mechanical dimensions, interface pin connections, electrical characteristics, and operating instructions. Key points include that it has a 128x64 dot matrix display, requires a DC 5V power supply, has interface pins for data/instruction input and output, and can be operated through instructions to turn on/off, set the display start line and page, write and read display data, and read the status.

Uploaded by

henrickramalho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

LTC

DOT MATRIX LIQUID CRYSTAL DISPLAY MODULE

LMG-SS12A64 Serial

USER MANUAL
LMG-SS12A64DRG(-H) LMG-SS12A64DEGB(-H) LMG-SS12A64DLGY(-H) LMG-SS12A64DLNW(-H) LMG-SS12A64DRY(-H) LMG-SS12A64DEYW(-H) LMG-SS12A64DLYY(-H)

PROPOSED BY
Design Approved

APPROVED

LIGHT-TECH

CONTENTS
1. 2 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Mechanical Specification Mechanical Diagram Interface Pin Connections Block And Power Supper Diagram Electrical Absolute Maximum Ratings Environmental Absolute Maximum Ratings Electrical Characteristics Electro-Optical Characteristics Timing Control Instruction Set Description Of Instructions Initializing And Programming Reliability Condition Functional Test & Inspection Criteria PAGE 2 2 2 2 3 3 3 3 3 4 4 5 6 6

PAGE 1 (LMG-SS12A64 Serial)

1.

Mechanical Specification
ITEM DOT MATRIX FORMAT MODULE DIMENSION VIEWING DISPLAY AREA ACTIVE DISPLAY AREA DOT SIZE DOT PITCH LMG-SSC12A64DRG(-H) LMG-SSC12A64DRY(-H) LMG-SSC12A64DEGB(-H) LMG-SSC12A64DEYW(-H) LMG-SSC12A64DLGY(-H) LMG-SSC12A64DLYY(-H) LMG-SSC12A64DLNW(-H) EL Use Inverter Type Inverter Input Inverter Output BACKLIGHT Half-Lift TIME LED Backlight Color LED Backlight Input BACKLIGHT Half-Lift TIME E mode LED Backlight Color LED Backlight Input BACKLIGHT Half-Lift TIME STANDARD VALUE UNIT 128 X 64 DOTS -93.0 (W) X 70.0 (H) X 9.5 (T) 93.0 (W) X 70.0 (H) X 14.0 (T) mm 72.0 (W) X 39.0 (H) mm 66.52 (W) X 33.24 (H) mm 0.48 (W) X 0.48 (H) mm 0.52 (W) X 0.52 (H) mm STN , Gray , 1/64 Duty , 1/9 Bias , 6 Oclock STN , Yellow Green , 1/64 Duty , 1/9 Bias , 6 Oclock STN , Gray , 1/64 Duty , 1/9 Bias , 6 Oclock , EL Backlight ( Color is Bule) STN , Yellow Green , 1/64 Duty , 1/9 Bias , 6 Oclock , EL Backlight ( Color is White) STN , Gray , 1/64 Duty , 1/9 Bias , 6 Oclock, LED Backlight STN , Yellow Green , 1/64 Duty , 1/9 Bias , 6 Oclock , LED Backlight STN , Blue , 1/64 Duty , 1/9 Bias , 6 Oclock , E mode LED Backlight (Color is White) SDEC-I002A DC +5V V 40 mA AC 90~110V V 400~700 Hz 3,000 HR. Yellow Green DC +4.2V V 300 mA 50,000 HR. White DC +3V V MAX 100 mA 20,000 HR.

2.

Mechanical Diagram

3. Interface Pin Connections


NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

4. Black And Power Supply Diagram

SYMBOL
VSS VDD VO D/I R/W E DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 CS1 CS2 /RST VEE A+(EL1) K-(EL2)

LEVEL
-H/L H/L H/L H/L H,HL H/L H/L H/L H/L H/L H/L H/L H/L H H L DC -5V ---

FUNCTION
GND ( 0V) DC +5V Contrast Adjust Data / Instruction code Read / Write Enable signal Data Bit 0 Data Bit 1 Data Bit 2 Data Bit 3 Data Bit 4 Data Bit 5 Data Bit 6 Data Bit 7 Chip 1 enable signal Chip 2 enable signal Reset signal Negative voltage output LED+(EL Backlight 1) LED-(EL Backlight 2)

PAGE 2 (LMG-SS12A64 Serial) 5. Electrical Absolute Maximum Ratings

ITEM SUPPLY VOLTAGE FOR LOGIC SUPPLY VOLTAGE FOR LCD INPUT VOLAGE

SYMBOL VDD-VSS VDD-VEE VI

MIN. --VSS

TYPE 5.0 ---

MAX. 6.5 10.0 VDD

UNIT V V V

6. Environmental absolute maximum ratings


ITEM Ambient Temperature Humidity Vibration Shock Remarks: NOTE (1) : Ta at 60 C : NOTE (2) : Ta < 40 C : Ta > 40 C : OPERATING MIN. MAX. 0/-20 C 50/70 C NOTE 1 -4.9m/s2 -29.4m/s2 STORAGE MIN. MAX. -10/-30 C 60/80 C NOTE 2 -19.6m/s2 -490.0m/s2 REMARKS -NOTE 1 Without Condensation XYZ Directions XYZ Directions

50 HR Max. 95% RH Max. Absolute humidity must be lower than the humidity of 95% at 40 C.

7. Electrical Characteristics
ITEM SYN VDD-VSS SUPPLY VOLTAGE FOR LOGIC VDD-VEE SUPPLY VOLTAGE FOR LCD VIH INPUT HIGH VOLTAGE VIL INPUT LOW VOLTAGE IDD SUPPLY CURRENT (LOGIC) ILCD SUPPLY CURRENT (LCD) NOTE (1) : CS1,CS2,R/W,D/I,DB0~7,E, and RST. CONDITION -Ta= 25 NOTE 1 NOTE 1 VDD=+5V,VEE=-5V VDD=+5V,VEE=-5V MIN. 4.5 8.0 0.7VDD 0 --TYPE 5.0 -----MAX. UNIT 5.5 V 17.0 V VDD V 0.3VDD V 4.0 mA 3.0 mA

8. Electro-Optical Characteristics
ITEM RESPONSE TIME FRAME FREQUENCY OPERATING VOLTAGE VIEWING ANGLE CONTRAST RATIO F-B R-L SYM tr tr tf tf fF Vop Ai Qi K TEMP (C) 0/-20 25 0/-20 25 -0 25 50 --25 MIN. -----12.3 11.0 10.2 55 60 -TYPE 2450/3264 204 600/800 50 -13.0 11.7 10.9 --22.8 MAX. -----13.7 12.4 11.6 ---UNIT ms ms ms ms Hz V V V deg deg --

9. Timing Control Write Operation

( NOTE 1 )

Read Operation ( NOTE 2 )

PAGE 3 (LMG-SS12A64 Serial)


Item Symbol Limit (Min.) Limit (Max.) Unit

E cycle E high level width E low level width E rise time E fall time Address set-up time Address hold time Data set-up time Data delay time Data hold time (write) Data hold time (read)

tcyc twhE twlE tr tf tas tah tdsw tddr tdhw tdhr

1000 450 450 --140 10 200 -10 20

---25 25 ---320 ---

ns ns ns ns ns ns ns ns ns ns ns

10. Instruction Set


FUNCTION R/W D/I DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 0 0 0 0 1 1 1 1 1 1/0 1. Display ON/OFF 0 0 1 1 display start line ( 0~63 ) 2. Display start line 0 0 1 0 1 1 1 page ( 0~7 ) 3. Set page ( X address) 0 0 1 Y address ( 0~63 ) 4. Set address 0 0 B 0 ON/ R 0 0 0 0 5. Status Read 1 U OFF E S S Y E T 0 1 Write Data 6. Write Display Data 7. Read Display Data 1 1 Read Data FUNCTION Controls the ON/OFF of the display. RAM data internal status are not affected. 1:ON, 0:OFF. Indicates the display data RAM displayed at the top of the screen. Sets the page (X address) of RAM at the page (X address) register. Sets the Y address at the Y address counter. Reads the status. RESET 1:Reset, 0:normal. ON/OFF 1: Display OFF, 0: Display ON. BUSY 1: In operation. 0: Ready Writes data (DB0~7) into display data RAM. After writing instruction, Y address is increased by 1 automatically. Reads data (DB0~7) from display data RAM to the data bus.

11. Description Of Instructions (1) Display ON/OFF


Code R/W 0 D/I 0 DB7 0 DB6 0 DB5 1 DB4 1 DB3 1 DB2 1 DB1 1 DB0 D

The display data appears when D is 1 and disappers when D is 0. Though the data is not on the screen width D=0, it remains in the display data RAM. Therefore, you can make it appear by changing D=0 or D=1. (2) Code Display start line R/W 0 D/I 0 DB7 1 DB6 1 DB5 A DB4 A DB3 A DB2 A DB1 A DB0 A

Z address AAAAAA (binary) of the display data RAM is set at the display start line register and displayed at the top of the screen. (3) Set page (X address) Code R/W 0 D/I 0 DB7 1 DB6 0 DB5 1 DB4 1 DB3 1 DB2 A DB1 A DB0 A

X address AAA (binary) of the display data RAM is set at the X address register. MPU is executed in this specified page until the next page is set. (4) Code Set Y address R/W 0 D/I 0 DB7 0 DB6 1 DB5 A DB4 A DB3 A

After that, writing or from

DB2 A

DB1 A

DB0 A

Y address AAAAAA (binary) of the display RAM is set at the Y address counter is increase by every time data is written or read to or from MPU.

PAGE 4 (LMG-SSC12A64 Serial)


0 1 2 3 4 5 .............................................................................................................................61 62 63 DB0

I DB7 DB0 I DB7 DB0 I DB7 DB0 I DB7 Address Configuration of Display RAM (5) Status Read Code R/W 1 BUSY : D/I 0 DB7 BUSY DB6 0

PAGE 0

X=0

PAGE 1 I PAGE 6

X=1

X=6

PAGE 7

X=7

DB5 ON/OFF

DB4 RESET

DB3 0

DB2 0

DB1 0

DB0 0

When BUSY is 1, The LSI is in internal operation. No instructions are accepted while BUSY is 1, so you should make sure that BUSY is 0 before writing the next instruction.

ON/OFF: This bit show the liquid crystal conditions ON condition or OFF condition. When ON/OFF is 1, the display is on OFF condition. When ON/OFF is 0, the display on ON condition. RESET: RESET=1 shows that the system is being initialized. In this condition, any instructions except Status Read instruction cannot be accepted. RESET=0 shows that initializing has finished and system is in the usual operation.

(6) Write Display Data Code R/W 0 D/I 1 DB7 D DB6 D DB5 D DB4 D DB3 D DB2 D DB1 D DB0 D

Writes 8-bit data DDDDDDDD (binary) into display data RAM. automatically. (7) Code Read Display Data R/W 1 D/I 1 DB7 D DB6 D DB5 D DB4 D

The Y address is increased by 1

DB3 D

DB2 D

DB1 D

DB0 D

Reads out 8-bit data DDDDDDDD (binary) from the display data RAM. The Y address is increased by 1 automatically. One dummy read is necessary soon after the address setting.

12. Initializing And Programming

PAGE 5 (LMG-SS12A64 Serial) 13. Reliability Condition TN Type STN Type

Normal Temp. Horizontal 30 Vertical () 10to 30 Operating Temperature -10 to 70 Storage Temperature -20 to 80 High Temperature (Power Off) 240 Hours @70 Low Temperature (Power Off) 240 Hours @-20 High Temperature (Power On) 240 Hours @70 Low Temperature (Power On) 240 Hours @-10 High Temperature & High 55/90%RH Humidity 240 Hours Thermal Shock C A 60min@-20 5 Cycle B B 5min@25 A C 60min@70 Expected Lift 50,000 Hours Viewing Angle
*

Wide Temp. 30 10to 30 -25 to 80 -35 to 90 240 Hours @90 240 Hours @-35 240 Hours @80 240 Hours @-25 75/90%RH 240 Hours 60min@-35 5min@25 60min@90 50,000 Hours

Normal Temp. 30 -10to 40 0 to 50 -20 to 70 240 Hours @65 240 Hours @-15 240 Hours @60 240 Hours @-10 45/90%RH 240 Hours 60min@-20 5min@25 60min@70 50,000 Hours

Wide Temp. 30 -10to 40 * -20 to 70 * -30 to 80 240 Hours @75 240 Hours @-25 240 Hours @70 240 Hours @-20 65/90%RH 240 Hours 60min@-30 5min@25 60min@80 50,000 Hours

Wide temp. version may not available for some products, Please consult our sales engineer or respresentative.

14. Functional Test & Inspection Criteria 14.1 Sample plan Sample plan according to MIL-STD-105D level 2, and acceptance/rejection criteria is. Base on : Major defect : AQL 0.65 Minor defect : AQL 2.5 14.2 Inspection condition Viewing distance for cosmetic inspection is 30cm with bare eyes, and under an environment of 800 lus (20W) light intensity. All direction for inspecting the sample should be within 45 against perpendicular line. 14.3 Definition of Inspection Zone in LCD

C A B

Character / Digit area Viewing area except Zone A ( Zone A + Zone B = minimum Viewing area ) Outside viewing area ( invisible area after assembly in customers product ) As a general rule, visual defects in Zone C are permissible, when it is no trouble for quality and assembly of customers product. 14.4 Major Defect All functional defects such as open ( or missing segment ), short, contrast differential, excess power consumption, smearing, leakage, etc. and overall outline dimension beyond the drawing. Are classified as major defects.

Zone A : Zone B : Zone C : Note :

PAGE 6 (LMG-SS12A64 Serial) 14.5 Minor Defect Except the Major defects above, all cosmetic defects are classified as minor defects.

Item No. Item to be Inspected 1. Spot defect ( Defects in spot from )

Inspection Standard Zone size (mm)

2.

3.

4.

Acceptable Qty A B C Acceptable Accepta0.15 ( clutering of spot ble not allowed ) 1 2 0.150.20 0 1 0.200.25 0 0 >0.25 Remarks : for dark/white spot, size is defined as =1/2(X+Y) Line defect Size (mm) Acceptable Qty ( Defects in line L W Zone form ) Length Width A B C AccepAccep- AccepW0.02 table table table 2 L3.0 W0.03 0 L>2.5 W0.03 2 L3.0 0.03<W0.05 0 L>2.5 0.03<W0.05 Counted as spot W>0.05 defect ( Follows item 14.5.1 ) Remarks: The total of spot defect and line defect shall not exceed four. Orientation defect Not allowed inside viewing area ( Zone A or Zone ( such as B) misalignment of L/C) Polarizing 14.5.4.1 Polarizer Position 1. Shifting in Position Should not exceed the glass outline dimension. 2. Incomplete covering of the viewing area due to Shifting is not allowed. 14.5.4.2 Seratches, bubble or dent on Glass/ Polarizer/Reflector, Bubble between Polarizer & Reflector/Glass: Size (mm) Acceptable Qty Zone A B C Acceptable Accep0.20 table 3 0.20<0.50 2 0.50<1.00 0 >1.00

Classification of defects Minor

Minor

Minor

Minor

PAGE 7 (LMG-SS12A64 Serial)

LIGHT-TECH ELECTRONIC
LIGHT-TECH www.LTC.com.tw