Ge Kompressor
Ge Kompressor
Ge Kompressor
Zero compromise
The 275GL+ excels in all evaluation criteria. Theres no choosing between power and emissions, or between fuel efciency and fuel exibility. With the 275GL+, there are no trade-offs.
Horsepower
100%*
100%*
100%*
* of Rated Load
87%*
75%*
3500 3000
Sample 1 622 Btu/ft3 WKI=113 Sample 2 1026 Btu/ft3 WKI=74 Sample 3 1050 Btu/ft3 WKI=71 Sample 4 1419 Btu/ft3 WKI=55 Sample 5 1633 Btu/ft3 WKI=42
275GL+ Performance
275GL+ Performance
Power (bhp) Power (bhp) BSFC (BTU/bhp-hr; +5% LHV) BSFC (BTU/bhp-hr; +5% LHV) Altitude w/o Derate; (ft) @ 100F Altitude w/o Derate; (ft) @ 100F Fuel Derate Begins at: Fuel Derate Begins at: Allowable Fuel RangeTop Allowable Fuel RangeBottom Allowable Fuel RangeTop NOx (g/bhp-hr)
3625 6539 6539 4000 4000 70 WKI ; 1125 Btu/ft3 70 WKI 3 3 35 WKI ; 2300 Btu/ft 1125 Btu/ft 3 600 Btu/ft 35 WKI 3 2300 0.5Btu/ft
600 Btu/ft3 1.7 0.5 0.7 1.7 507 0.7 507
4835 6499 6499 3000 3000 70 WKI ; 1125 Btu/ft3 70 WKI 3 3 35 WKI ; 2300 Btu/ft 1125 Btu/ft 3 60035 Btu/ft WKI 3 2300 0.5 Btu/ft
600 Btu/ft3 1.6 0.5 0.7 1.6 498 0.7 498
In addition, the 275GL+ has lower greenhouse gas emissions and a smaller carbon footprint than competitive engines. Greenhouse gases (CO2e) are about more than CO2; unburned methane must also be consideredat 21 times the effect of the CO2. Choosing a 275GL+ and its fuel-efciency advantage provides low unburned methane and CO2 emissions, reducing the effect on the environment, compared to historical engines.
Because eld gases vary greatly and can change over time, the 275GL+ was built to maintain full power on a wide range of fuels, without the added cost of a fuel treatment skid. The 275GL+ can run on fuel with up to 1000ppm H2S without treatment and operates on a wide range of fuels from 600 Btu/ft3 to 2300 Btu/ft3. This engine is built to give you the kind of exibility youll need for more options and better prots.
The 275GL+ represents the most advanced generation of high-horsepower, lean-burn engines, leading the industry across a broad spectrum of evaluation criteria.
Ecomagination is GEs commitment to building innovative solutions for todays environmental challenges while driving economic growth. The Waukesha 275GL+ meets this commitment by offering industryleading emissions levels and efciency without sacricing power or application exibility. With a smaller carbon footprint, lower fuel costs and more gas compressed, the 275GL+ is an engine without trade-offs.
*Trademark of General Electric Company. All other trademarks are the property of their respective owners.
275GL+
control
Proven ESM control system Factory-mounted, calibrated and tested on all 275GL+ engines, the Engine System Manager (ESM) dramatically reduces on-site setup time and requirements. With a single, closed-loop control system integrating all engine functionality, starting and loading the engine takes only a few minutes. Once running, an HMI panel provides an easy-to-read display of engine operating parameters. Unlimited, free downloads ensure you always have the most current software to control the engine.
power
The power you need when it counts the most Its the most-recognized equation in gas compression: Power = Throughput = Prot The 275GL+ delivers superior power output and efciency that directly impacts the bottom line. The 16-cylinder model is rated 4835 bhp (3605 kWb), with the 12-cylinder version rated 3625 bhp (2720 kWb). These higher power ratings maximize throughput and prots, while lower fuel consumption provides a cost savings over other engines. Whatever your requirements, the 275GL+ ensures you have the reliable power you need to maximize prots.
ease of use
Simplied packaging and service The 275GL+ is easy to package. By minimizing the number of connections required, valuable time and money are saved on the shop oor. Factorymounted lube oil system and cooling system thermostats are included on the engine. In addition, the pre-lube pump is fully integrated and enginemounted. Quick disconnects on the ignition coils and thermocouples mean easy removal and servicing. Placing the turbochargers at the front end of the engine reduces piping requirements, and eliminates interference during cylinder-head maintenance. 4 5 6
Control System 1 ESM 2 HMI panel 3 Wiring trays Lube Oil System 4 Centrifugal oil ltration 5 Oil cooler 6 Oil lter Pre-lube pump (Not visible)
3 2
Cooling System 7 Resized cooling pump outlets 8 Integrated thermostats & bypass jacket water piping 9 Integrated thermostats & bypass auxiliary water piping
ongoing
Purchasing an engine is only the beginning of a relationship. Were in it for the long haul, supporting you with ongoing service, quality parts and our distribution network to ensure your engine delivers everything you need and more.
GE Energy 1101 West St. Paul Avenue Waukesha, WI 53188-4999 Phone: (262) 547-3311 Fax: (262) 549-2795 Visit us online at: www.waukeshaengine.com 2011 General Electric Company All Rights Reserved
A legacy of reliability and innovation GE and Waukesha represent over 200 years of commitment to advanced technology that continues to drive the world forward. With a reputation for rugged durability and ongoing design advancements, Waukesha engines are the sound investment you can depend on in mission-critical applications. Now a part of GEs Gas Engines business, enhanced support in the form of parts, service and a network of distributors makes us an even stronger partner for todays global energy industry. For more information, visit ge-energy.com/275GL.
Visit us online at: www.waukeshaengine.com 2011 General Electric Company All Rights Reserved GEA-19065 (66155) Bulletin 1426 08/11