Submittal Data: End Suction

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Submittal Data

Hydraulic Data Maximum Flow

3657 Close Coupled End Suction MODEL : 4SS1M2B04SS B 3500


Motor Data 3657/3757 Model 4SS1M2B04SS B 3500 Qty.

Flow at Duty Point Maximum TDH TDH at Duty Point NPSH R Voltage / Phase / Enclosure 240 US g.p.m. 202 ft

520 US g.p.m.

162 ft

11 ft

460V 3PH ODP

Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: 14.03.2014

Job: Contractor: Company: Approved by:

Date:

Engineering Data
Pump Code: 4SS1M2B04SS B 3500 Pump Size: 2 x 3 - 7 Pump Max Horsepow er: 0 hp Pump Horsepow er at Rating Point: 14.58 hp Pump Shut Off Head: 202 ft Motor Speed: 3450 rpm Max. Temperature: 212 F Liquid: Water Motor Code: C13741 System Input Pow er: 3~ 460 V Motor Rated Horsepow er: 15.00 hp Max. Frequency:60 Electrical Enclosures:ODP Motor Standard: NEMA Suction Flange Standard:ANSI Suction Flange Rating: Class 125 Suction Size: 2" Cast Iron Discharge Flange Standard:ANSI Discharge Flange Rating: Class 125 Discharge:1 1/2" Cast Iron Approximate Net Weight: 167 lb Impeller Size: 63 /4 " Impeller Construction: Cerrado Impeller Type: Rodete radial Impeller Material: 316 Stainless Steel Investment Cast Sense of Rotation: en el sentido del reloj Shaft Seal: Carbon/Sil-Carbide/Viton

Standard Equipment / Capability:

Superior Materials of Constructions: Precision investment cast 316 stainless steel liquid end components for corrosion resistance and strength. Frame Mounted Design: Flexibility of installation and driver arrangements. Enclosed Impeller Design: Maximum efficiency and service life with no need for clearance adjustment. Key driven shaft connection with locknut. Back Pull-Out Design: Simplifies maintenance by allowing the casing to remain in the piping during disassembly. Close-Coupled Design: Compact design saves space and simplifies installation. Casing features: Investment cast AISI type 316 stainless steel, volute design for maximum efficiency. Vertical discharge standard, field modifiable to four standard positions. Shaft and Sleeve: High strength steel, keyed design non-wetted. Protected from pumpage by O-ring seal and hooked design AISI type 316 stainless steel shaft sleeve. Mechanical Seals: Standard John Crane Type 21 seal with carbon versus ceramic faces, Viton elastomers and 316 stainless steel metal components. Options are available for high temperature and abrasives. Drive Motors: NEMA standard JM frame (close coupled) or T frame (frame mounted) are available in both single and three phase with a variety of enclosures and voltages to match your service requiremen

Printed f rom data f ile 14.03.2014

Performance Data
Hydraulic Data Maximum Flow

3657 Close Coupled End Suction MODEL : 4SS1M2B04SS B 3500


Motor Data 3657/3757 Model 4SS1M2B04SS B 3500 Qty.

Flow at Duty Point Maximum TDH TDH at Duty Point NPSH R Voltage / Phase / Enclosure 240 US g.p.m. 202 ft

520 US g.p.m.

162 ft

11 ft

460V 3PH ODP

Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: 14.03.2014 Fluid: Water [ft] Altura de impulsin 220 7 210 6.75 200 190 6.375 180 170 160 5.937 150 140 130 5.5 5.375 120 110 5.063 100 4.625 90 80 4.375 70 60 3.875 50 40 30 20 [%] Rendimiento 70 60 50 40 30 20 10 Valores NPSH [ft] 20 15 10 5 [hp] Potencia en el eje P2 16 12 8 4 0 40 80 120 160 3.875 (P2) 250 US g.p.m. 200 240 3.875 Duty Chart: 3500 RPM Area de aplicacin 50% 60% 65% 70% 74% 76%

Job: Contractor: Company: Approved by:

Date:

78% Rend. 79.4% 79.3% 176 ft

78.5% 76.8% 74% 72.7% 70% 66.6% 63.3% 55% 50%

77.6 % 3.875 7 6.75

7 6.75

10.7 ft 7 (P2) 6.75 (P2) 14.6 hp

280

320

360

400

440

480

520

[US g.p.m.]

Printed f rom data f ile 14.03.2014

Unit Dimensions
Hydraulic Data Maximum Flow

3657 Close Coupled End Suction MODEL : 4SS1M2B04SS B 3500


Motor Data 3657/3757 Model 4SS1M2B04SS B 3500 Qty.

Flow at Duty Point Maximum TDH TDH at Duty Point NPSH R Voltage / Phase / Enclosure 240 US g.p.m. 202 ft

520 US g.p.m.

162 ft

11 ft

460V 3PH ODP

Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: 14.03.2014

Job: Contractor: Company: Approved by:

Date:

Dimension
A AB B C max C max D liquid end D Discharge E F G

Value
10 1/2 9 1/16 8 1/2 10 10 3/4 5 1/4 5 1/4 2 4 1/4 3 1/2 5 /8

Dimension
H L O max R Suction W X Z

Value
7

/16 10 5/8 11 1/4 3 3 4 1/4 6 4 1/4

Printed f rom data f ile 14.03.2014