Q4B Evaluation and Recommendation of Pharmacopoeial Texts For Use in The ICH Regions Annex 5
Q4B Evaluation and Recommendation of Pharmacopoeial Texts For Use in The ICH Regions Annex 5
Chapter
This draft guidance, when finalized, will represent the Food and Drug Administration's (FDA's) current thinking on this topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of the applicable statutes and regulations. If you want to discuss an alternative approach, contact the FDA staff responsible for implementing this guidance. If you cannot identify the appropriate FDA staff, call the appropriate number listed on the title page of this guidance.
For questions regarding this draft document contact (CDER) Robert King 301-796-1242, or (CBER) Christopher Joneckis 301-827-0373.
Q4B - Annex 5
Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions
ON
At Step 2 of the ICH Process, a consensus draft text or guideline, agreed by the appropriate ICH Expert Working Group, is transmitted by the ICH Steering Committee to the regulatory authorities of the three ICH regions (the European Union, Japan and the USA) for internal and external consultation, according to national or regional procedures.
Q4B -- Annex 5 Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions
ON
1. Introduction
This annex is the result of the Q4B process for Disintegration Test General Chapter. The proposed texts were submitted by the Pharmacopoeial Discussion Group (PDG).
2. Q4B Outcome
2.1 Analytical Procedures The ICH Steering Committee, based on the evaluation by the Q4B Expert Working Group (EWG), recommends that for tablets and capsules, the official pharmacopoeial texts, Ph.Eur. 2.9.1. Disintegration of Tablets and Capsules, JP 6.09 Disintegration Test, and USP <701> Disintegration can be used as interchangeable in the ICH regions subject to the conditions detailed below. Testing conditions for specific dosage forms are outside the scope of the harmonization of this chapter. 2.1.1 The Disintegration Test is not considered to be interchangeable in the three regions for tablets and capsules larger than 18 millimeters (mm) long. The Disintegration Test is not considered to be interchangeable in the three regions for enteric coated preparations. Product-specific parameters such as media and the use of discs should be specified in the application dossier.
2.1.2
2.1.3
2.2 Acceptance Criteria Acceptance criteria are outside the scope of the harmonization of this chapter and should be specified in the application dossier.
Final signoff on Step 2 Annex 5 Disintegration Test June 5, 2008 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125
chosen method is acceptable and suitable for a specific material or product, irrespective of the origin of the method. 4.3 EU consideration: For the European Union, the monographs of the Ph. Eur. have mandatory applicability. Regulatory authorities can accept the reference in a marketing authorisation application, renewal or variation application citing the use of the corresponding text from another pharmacopoeia as referenced in Section 2.1, in accordance with the conditions set out in this annex, as fulfilling the requirements for compliance with the Ph. Eur. Chapter 2.9.1., on the basis of the declaration of interchangeability made above. 4.4 MHLW consideration: The pharmacopoeial texts referenced in Section 2 of this annex can be used as interchangeable in accordance with the conditions set out in this annex. Details of implementation requirements will be provided in the notification by MHLW when this annex is implemented.
Final signoff on Step 2 Annex 5 Disintegration Test June 5, 2008 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150
151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170
position by two plates, each 88 to 92 mm in diameter and 5 to 8.5 mm in thickness, with six holes, each 22 to 26 mm in diameter, equidistant from the center of the plate and equally spaced from one another. Attached to the under surface of the lower plate is a woven stainless steel wire cloth, which has a plain square weave with 1.8- to 2.2-mm apertures and with a wire diameter of 0.57 to 0.66 mm. The parts of the apparatus are assembled and rigidly held by means of three bolts passing through the two plates. A suitable means is provided to suspend the basket-rack assembly from the raising and lowering device using a point on its axis. The basket-rack assembly conforms to the dimensions found in Fig. 6.09-1. The design of the basket-rack assembly may be varied somewhat pro-vided the specifications for the glass tubes and the screen mesh size are maintained: for example, in order to secure the glass tubes and the upper and the lower plastic plates in position at the top or the bottom, an acid-resistant metal plate, 88 - 92 mm in diameter and 0.5 - 1 mm in thickness, having 6 perforations, each about 22 to 26 mm in diameter, may be used which coincide with those of the upper plastic plate and upper open ends of the glass tubes. Disks -- The use of disks is permitted only where specified or allowed. Each tube is provided with a cylindrical disk 9.5 0.15 mm thick and 20.7 0.15 mm in diameter. The disk is made of a suitable, transparent plastic material having a specific gravity of between 1.18 and 1.20. Five parallel 2 0.1 mm holes extend between the ends of the cylinder. One of the holes is centered on the cylindrical axis. The other holes are centered 6 0.2 mm from the axis on imaginary lines perpendicular to the axis and parallel to each other. Four identical trapezoidal-shaped planes are cut into the wall of the cylinder, nearly perpendicular to the
Final signoff on Step 2 Annex 5 Disintegration Test June 5, 2008 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231
ends of the cylinder. The trapezoidal shape is symmetrical; its parallel sides coincide with the ends of the cylinder and are parallel to an imaginary line connecting the centers of two adjacent holes 6 mm from the cylindrical axis. The parallel side of the trapezoid on the bottom of the cylinder has a length of 1.6 0.1 mm, and its bottom edges lie at a depth of 1.5 ~ 1.8 mm from the cylinder's circumference. The parallel side of the trapezoid on the top of the cylinder has a length of 9.4 0.2 mm, and its center lies at a depth of 2.6 0.1 mm from the cylinder's circumference. All surfaces of the disk are smooth. If the use of disks is specified, add a disk to each tube, and operate the apparatus as directed under Procedure. The disks conform to dimensions found in Fig. 6.09-1. The use of automatic detection employing modified disks is permitted where the use of disks is specified or allowed. Such disks must comply with the requirements for density and dimension given in this chapter. Auxiliary tube -- The auxiliary tube, as illustrated in Fig. 6.09-2, consists of a plastic tube D, 12 0.2 mm in inside diameter, 17 0.2 mm in outside diameter, 20 1 mm in length, having both outside ends screw-cut, and two plastic rings A, each 12 0.2 mm in inside diameter, 17 0.2 mm in outside diameter, 2.5 - 4.5 mm in length, having one inside end screw-cut. Acidresistant woven wire gauze having 0.42-mm openings and 0.29-mm wire diameter is placed in each plastic ring and the rings are attached by screws to each end of the plastic tube. The distance between two wire gauzes is 20 1 mm. A handle of an acidresistant wire, 1 mm in diameter and 80 5 mm in length, is attached to the mid portion of the plastic tube. The auxiliary tube is used for the test of granules and capsules containing enteric coated granules. Procedure
1) Immediate-release preparation
In case of tablets, capsules and pills (except for pills containing crude drugs) place 1 dosage unit in each of the six tubes of the basket, and if prescribed add a disk. Unless otherwise specified, operate the apparatus, using water as the immersion fluid, maintained at 37 2 C as the immersion fluid. Unless otherwise specified, carry out the test for 20 minutes for capsules, 30 minutes for plain tablets, and 60 minutes for coated tablets and pills. Lift the basket from the fluid, and observe the dosage units. Complete disintegration is defined as that state in which any residue of the unit, except fragments of insoluble coating or capsule shell, remaining on the screen of the test apparatus or adhering to the lower surface of the disks, if used, is a soft mass having no palpably firm core. The test is met if all of the dosage units have disintegrated completely. If 1 or 2 dosage units fail to disintegrate, repeat the test on 12 additional dosage units. The test is met if not less than 16 of the total of 18 dosage units tested are disintegrated. For pills containing crude drugs, carry out the test for 60 minutes in the same manner, using 1st fluid for disintegration test as the immersion fluid. When any residue of the unit is observed, carry out the test successively for 60 minutes, using 2nd fluid for disintegration test. In case of granules, shake granules on a No. 30 (500 pm) sieve as directed in (1) Granules under Particle Size Distribution Test for Preparations <6.03>, transfer 0.10g of the residue on the sieve to each of the 6 auxiliary tubes, secure the 6 tubes to the bottom of the basket tightly, and operate the apparatus, using water as the immersion fluid, maintained at 37 2 C as the immersion fluid, unless otherwise specified. Observe the samples after 30 minutes of operation for plain granules and after 60 minutes for coated granules, unless otherwise specified. Complete disintegration is defined as that state in which any residue of the granules, except fragments of insoluble coating in the auxiliary tube, is a soft mass having no palpably firm core. The test is met if all of 6 samples in the auxiliary tubes have disintegrated completely. If 1 or 2 samples fail to disintegrate, repeat the test on 12 additional samples. The test is met if not less than 16 of the total of 18 samples tested are disintegrated.
2) Enteric coated preparations Unless otherwise specified, perform the following two tests, (a) the test with 1st fluid for disintegration test and (b) the test with the 2nd fluid for disintegration test, separately. (1) Enteric coated tablet and capsule (a) The test with 1st fluid for disintegration test Carry out the test for 120 minutes, using 1st fluid for disintegration test according to the procedure described in immediate release preparations. Disintegration is defined as that state in which the tablet or capsule is broken or the enteric coating film is ruptured or broken. The test is met if none of six dosage units is disintegrated. If 1 or 2 dosage units are disintegrated, repeat the test on additional 12 dosage units. The test is met if not less than 16 of the total of 18 dosage units tested are not disintegrated. (b) The test with 2nd fluid for disintegration test According to the procedure described in immediate-release preparations, carry out the test with new dosage units for 60 minutes, using 2nd fluid for disintegration test and determine if the test is met or not. (2) Enteric coated granules and capsules containing the enteric coated granules Shake granules or contents taken out from capsules on a No. 30 (500 pm) sieve as directed in (1) Granules under Particle Size Distribution Test for Preparations <6.03>, transfer 0.10 g of the residue on the sieve to each of the 6 auxiliary tubes, secure the 6 tubes to the bottom of the basket tightly, and operate the apparatus, using the 1st and 2nd fluids for disintegration test. (a) The test with 1st fluid for disintegration test According to the procedure described in immediate-release preparations, carry out the test for 60 minutes, using 1st fluid for disintegration test. The test is met if particles fallen from the openings of the wire gauze number not more than 15. (b) The test with 2nd fluid for disintegration test According to the procedure described in immediate-release preparations, carry out the test with new samples for 30 minutes, using 2nd fluid for disintegration test and determine if test is met or not.