FA168CPS / FA168CPSSIA FA168CPSSIA FA148CP / FA148CPSIA

Security Systems
Programming Guide

ARMED

READY

A B C D

1 4

..

2 )9); 56-56
6

356); 6*;2)55 9 +01 #

):

71 56)

8 0

+ ,-

4-),;

FA 26 0

ARMED

READY

ON

OFF

AWAY

1 4

..

2 )9); 5 6-56 8+ 0
,-

STAY

3 56); 6 *;2)55 9 +01 #


-

):

71 56) 6
PAGE
4-),;

FA 5 6 0

K5305-5PRV5 11/08 Rev. B

TABLE OF CONTENTS
PROGRAMMING MODE COMMANDS.....................................................................................................................3 DATA FIELD PROGRAMMING FORM .....................................................................................................................4 CONFIGURABLE ZONE TYPES WORKSHEETS..................................................................................................17 56 ZONE PROGRAMMING MENU MODE............................................................................................................18 58 EXPERT ZONE PROGRAM MODE..................................................................................................................20 WIRELESS KEY PROGRAMMING TEMPLATES ..................................................................................................21 57 FUNCTION KEY PROGRAMMING MENU MODE...........................................................................................23 OUTPUT DEVICE PROGRAMMING GENERAL INFORMATION (*79/*80 Menu Mode)......................................24 79 RELAY/POWERLINE CARRRIER DEVICE (X-10) PROGRAMMING MENU MODE .....................................24 80 OUTPUT FUNCTION MENU MODE ................................................................................................................25 81 ZONE LIST MENU MODE ................................................................................................................................27 82 ALPHA DESCRIPTOR MENU MODE ..............................................................................................................28 ALPHA VOCABULARY LIST (For Entering Zone Descriptors)..........................................................................30 SETTING SCHEDULES...........................................................................................................................................31 AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS...................................................................32 SETTING THE REAL-TIME CLOCK .......................................................................................................................32 29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming) .................................................33 ZONE TYPE DEFINITIONS .....................................................................................................................................34 UL NOTICES............................................................................................................................................................35 SIA QUICK REFERENCE GUIDE ...........................................................................................................................35 WORKSHEET FOR 56 ZONE PROGRAMMING ..................................................................................................36 WORKSHEET FOR 57 FUNCTION KEY PROGRAMMING .................................................................................37 WORKSHEET FOR 79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING ..........................................37 WORKSHEET FOR 81 ZONE LIST PROGRAMMING .........................................................................................37 WORKSHEET FOR 80 OUTPUT FUNCTION PROGRAMMING..........................................................................38 WORKSHEET FOR SCHEDULES ..........................................................................................................................39 TABLE OF DEVICE ADDRESSES ..........................................................................................................................39 5800 SERIES TRANSMITTER INPUT LOOP IDENTIFICATION............................................................................40

PROGRAMMING MODE COMMANDS


TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [] and [#] at the same time, within 50 seconds of powering up (this method must be used if 98 was used to exit program mode). OR B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
PROGRAMMING COMMANDS

Task Go to a Data Field Entering Data

Command/Explanation Press [] + [Field Number], followed by the required entry. When the desired field number appears, simply make the required entry. When the last entry for a field is entered, the keypad beeps three times and automatically displays the next data field in sequence. If the number of digits that you need to enter in a data field is less than the maximum digits available (for example, the phone number fields *41, *42), enter the desired data, then press [ ] to end the entry. The next data field number is displayed. Review a Data Field Press [#] + [Field Number]. Data will be displayed for that field number. No changes will be accepted in this mode. Deleting an Entry Press [] + [Field Number] + []. (Applies only to fields 40 thru *46, *94, and pager fields) Initialize Download ID Press 96. Initializes download ID and subscriber account number. Reset Factory Defaults Press 97. Sets all data fields to original factory default values. Zone Programming Press 56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF transmitters. Function Key Programming Press 57. Unlabeled keypad keys (known as ABCD keys) for special functions Zone Programming Press 58. Same options as *56 mode, but with fewer prompts. Intended for those familiar (Expert Mode) with this type of programming, otherwise *56 mode is recommended. Output Device Mapping Press 79. Assign module addresses and map individual relays/powerline carrier devices Output Programming Press 80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers Zone List Programming Press 81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc. Alpha Programming Press 82. Zone alpha descriptors IP/GSM Programming Press 29. For programming the IP/GSM options. Exit Program Mode with Press 98. Exits programming mode and prevents re-entry by: Installer Code + 8 + 0 + 0. installer code lockout To reenter programming mode, the system must be powered down, then powered up. Then use method A above. See field *88 for other *98 Program mode lockout options. Exit Program Mode Press 99. Exits program mode and allows re-entry by: Installer Code + 8 + 0 + 0 or method A above. Enter code + [#] +64. Create schedules to automate various system functions. Scheduling Mode Site-Initiated Download Installer code + [#] + 1 (perform while system is disarmed and in normal mode) AVS QUICK PROGRAMMING COMMANDS (for AAV sessions using the AVS system) For controls with the following firmware revision levels, these commands automatically configure the control for AVS operation. FA148CP = version 6.0 or higher; FA168CPS = version 7.0 or higher installer code + [#] + 03: enable AVS operation installer code + [#] + 04: enable AVS operation and enable panels sounds on the AVST speaker installer code + [#] + 05: remove all programming options that were set if [#] + 03 quick command was performed installer code + [#] + 06: remove all programming options that were set if [#] + 04 quick command was performed Refer to the AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS section for details on the specific options that are set with each command, depending on the control used. To select the AAV session communication path (phone line/communication device), see field 55 Dynamic Signaling Priority. To enable AAV operation, use 91 Options field (option 4).

Special Messages
OC = OPEN CIRCUIT (no communication between Keypad and Control). EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number). After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This will revert to a Ready message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this delay by pressing [#] + [0]. If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after you correct the programming.

IMPORTANT: The Real-Time Clock must be set before the end of the installation. See procedure in the Setting the Real-Time Clock section of this manual.

DATA FIELD PROGRAMMING FORM


Entries apply to the FA168CPS/FA168CPSSIA and FA148CP/FA148CPSIA controls, except entries shown in dashed boxes, which apply only to the FA168CPS/FA168CPSSIA (partition entries) and are not applicable to the FA148CP/FA148CPSIA controls. SIA-Compliant Controls: Where noted, certain fields have special settings when used with the FA168CPSSIA and FA148CPSIA SIA-Compliant controls (indicated by SIA-Compliant Controls in reverse type and heavy borders for easy identification). Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. SIA Guidelines for Non-SIA-Compliant Controls: Notes in certain fields give instructions for programming the FA168CPS/FA148CP for False Alarm Reduction (these controls can be programmed to reduce false alarms, but they are not fully SIA compliant).

SYSTEM SETUP (2029)

20
21

Installer Code
Enter 4 digits, 0-9

[4112]

The Installer Code is used to assign the 4-digit Master Security Code. The Installer Code can perform all system functions except it cannot disarm the system unless it was used to arm the system.
[0,0]
Part. 1 Part.2

Quick Arm Enable


0 = no 1 = yes

If enabled, users can press the [#] followed by an arming key to arm the system instead of using a security code. The security code is always needed to disarm the system.
[0]

22 23

RF Jam Option
0 = no RF Jam detection 1 = send RF Jam report

If enabled, a report is sent if the system detects an RF jamming signal.


UL: must be 1 if wireless devices are used [0,0]

Quick (Forced) Bypass

0 = no quick bypass Part. 1 Part. 2 1 = allow quick bypass (code + [6] + [#] ) Zones bypassed by this function will be displayed after the bypass is initiated.
UL: must be 0

24

RF House ID Code
00 = disable all wireless keypad use 0131 = using 5827, 5827BD or 5804BD keypad
P1

|
P2

|
Common

[00,00,00]

The House ID identifies receivers and wireless keypads. If a 5827 or 5827BD Wireless Keypad or 5804BD Transmitter is being used, a House ID code must be entered and the keypad set to the same House ID. You can assign RF house ID for each partition
[0]

26

Chime By Zone
0 = no (chimes on fault of any entry/exit or perimeter zone when chime mode on) 1 = yes (chimes on fault of specific zones listed in chime zone list 3 when Chime mode on)

If yes, list chime zones on zone list 3 using *81 Menu mode. If enabled, you can define the specific zones intended to chime when faulted while the system is in Chime mode.

27

Powerline Carrier Device (X10) House Code


0=A 1=B 2=C 3 =D 4=E 5 =F 6=G 7=H 8=I 9=J #10 = K #11 = L #12 = M #13 = N #14 = O #15 = P

[0]

Powerline Carrier devices require a House ID, identified in this field. Program Powerline Carrier devices in interactive modes 79, 80 and 81.
UL: not for fire or UL installations

28

Access Code For Phone Module


00 = disable 1st digit: enter 19 2nd digit: enter # + 11 for "", or # + 12 for "#".

[00]

(Partition 1 only)

You must assign a 2-digit access code for the 4286 Phone Module, if used. Example: If desired access code is 7, then 7 is the first entry, and [#] + 11 (for ) is the second entry. NOTE: A 0 in either digit disables the phone module.
UL: must be 00 for UL Commercial Burg. installations

This is a Menu Mode command, not a data field, for programming IP/GSM communication device options. See 29 Menu Mode section later in this document.

29 Enable IP/GSM Communication Device Menu Mode (pass-through programming)

31

Single Alarm Sounding Per Zone


0 = unlimited sounding 1 = one alarm sounding per zone SIA-Compliant Controls: If 0 selected, alarm sounding per zone will be the same as the number of reports in armed period set in field *93 (1 if one report, 2 if 2 reports, unlimited for zones in zone list 7).

[0]

If enabled, limits alarm sounding on the bell output to once per zone per armed period.

32

Fire Alarm Sounder Timeout


0 = sound stops at timeout selected in field 33 1 = no timeout; sounds until manually turned off

[0]

This control complies with NFPA requirements for temporal pulse sounding of fire notification appliances. Temporal pulse sounding for a fire alarm consists of the following: 3 pulses pause 3 pulses pause 3
pulses. UL: must be 1 for fire installations

33

Alarm Sounder (Bell) Timeout


0 = none 1 = 4 min 2 = 8 min 3 =12 min 4 = 16 min

[1]

This field determines whether the external sounder will shut off after time allotted, or continue until manually turned off.
UL: For residential fire alarm installation, must be set for a minimum of 4 min (option 1); for UL Commercial Burglary installations, must be minimum 16 min (option 4)

34

Exit Delay
00 - 96 = 0 - 96 secs 97 = 120 secs SIA-Compliant Controls: 45 - 96 = 45 - 96 secs; 97 = 120 secs NOTE: Entries less than 45 will result in a 45-second delay.

|
Part. 1

|
Part. 2

[60,60]

The system waits the time entered before arming entry/exit zones. If the entry/exit door is left open after this time expires, an alarm will occur. Common zones use same delay as partition 1. SIA Guidelines: minimum exit delay is 45 seconds Common zones use part. 1 delay.
UL installations: For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit time must not exceed 60 seconds.

35

Entry Delay #1
00 - 96 = 0 - 96 seconds 97 = 120 secs 98 = 180 secs 99 = 240 secs SIA-Compliant Controls: 30-96 = 30 - 96 secs; 97 = 120 secs; 98 = 180 secs; 99 = 240 secs NOTE: Entries less than 30 will result in a 30-second delay.

|
Part. 1

|
Part. 2

[30,30]

Upon entering, the system must be disarmed before the time entered expires, otherwise it sounds an alarm. Common zones use same delay as part 1. SIA Guidelines: minimum entry delay is 30 seconds
For UL Residential Burglary Alarm installations, must be set for a maximum of 30 seconds; entry delay plus dial delay should not exceed 1 min. For UL Commercial Burglar Alarm, total entry delay may not exceed 45 seconds. Upon entering, the system must be disarmed before the time entered expires, otherwise it sounds an alarm.

36 37

Entry Delay #2
See *35 Entry Delay 1 for entries.

|
Part. 1

|
Part. 2

[30,30]

Audible Exit Warning


0 = no; 1 = yes SIA-Compliant Controls: Feature always enabled; field does not exist.
Part. 1

[1,1]
Part. 2

Warning sound consists of slow continuous beeps until the last 10 seconds, and then it changes to fast beeps. Sound ends when exit time expires. SIA Guidelines: must be enabled
[0,0]
Part. 1 Part. 2

38

Confirmation Of Arming Ding


0 = no 1 = yes (wired keypads and RF) 2 = yes, RF only (except 5827, 5827BD)

Confirmation of arming is 1/2-sec external sounder ding. If 1 selected, ding occurs when closing report is sent if open/close reporting is enabled, or at the end of Exit Delay. If 2 selected, ding occurs upon reception of the wireless arming command.
UL: must be 1 for UL Commercial Burglar Alarm inst.

39

Power Up In Previous State


0 = no, always power up disarmed; 1 = yes, power up in previous state SIA-Compliant Controls: Feature always enabled; field does not exist.

When the system powers up armed, an alarm will occur 1 minute after arming if a zone is faulted. Note that if the previous state was armed Away or Stay, the system ignores sensor changes for 1 minute, which allows sensors such as PIRs to stabilize. UL: must be 1 SIA Guidelines: must be 1

DIALER PROGRAMMING (40 42)

40

PABX Access Code or Call Waiting Disable


Enter up to 6 digits. To clear entries, press 40. If call waiting is used, enter call waiting disable digits (#+11) 70 plus # + 13 (pause). SIA-Compliant Controls: If call waiting is used, enter call waiting disable digits as described above, and also set Call Waiting Disable option in field *91.

Call Waiting: If the subscribers phone service has call waiting (and is not using PABX), enter *70 (# + 11) plus # + 13 (pause) as the PABX entry to disable call waiting during control panel calls. If the subscriber does not have call waiting and is not using PABX, make no entry in this field. NOTES: 1. The call waiting disable feature cannot be used on a PABX line. 2. Using Call Waiting Disable on a non-call waiting line will prevent successful communication to the central station.

41 42

Primary Phone No. Secondary Phone No.


Do not fill unused spaces. 09 #+11 for '' #+12 for '#' #+13 for a 2-second pause

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

| |

Enter up to 20 digits. To clear entries, press 41 or 42 respectively. Enter the respective phone numbers. If fewer than the maximum digits entered, exit the field by pressing []. The next data field number is displayed. | | | / | | | /
| | | / | | | /

43 44 45 46

Partition 1 Primary Acct. No. Part. 1 Secondary Acct. No. Partition 2 Primary Acct. No. Partition 2 Secondary Acct. No.
Enter 4 or 10 digits, as chosen in *48 Report Format. Enter digits 09; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F.

| | | | | | | | | |
| | | | | | | | | |

[FFFFFFFFFF] [FFFFFFFFFF] [FFFFFFFFFF] [FFFFFFFFFF]

Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account number for 0000-0999. E.g., For Acct. B234, enter: #+11 + 2 + 3 + 4 To clear entries in a given field, press *43*, *44*, *45*, or *46* based on the field being programmed
[1]

47

Phone System Select


If Cent. Sta. is not on a WATS line: 0=Pulse Dial; 1=Tone Dial If Cent. Sta. is on a WATS line: 2 = Pulse Dial ; 3 = Tone Dial

Select the type of phone service for the installation.

48

Report F ormat
0 = 3+1, 4+1 ADEMCO L/S STANDARD 1 = 3+1, 4+1 RADIONICS STANDARD; 2 = 4+2 ADEMCO L/S STAND. 3 = 4+2 RADIONICS STANDARD 5 = 10-digit ADEMCO CONTACT ID REPORTING 6 = 4+2 ADEMCO EXPRESS 7 = 4-digit ADEMCO CONTACT ID REPORTING 8 = 3+1, 4+1 ADEMCO L/S EXP.; 9 = 3+1, 4+1 RADIONICS EXP
primary

[77]
secondary

Select the format for primary/secondary phone numbers

49

Split/Dual Reporting
0 = Standard/backup reporting only (all to primary) 1-5 = see table at right

[0]

Backup Reporting: All reports are sent only to the primary number unless unsuccessful after 8 attempts. If unsuccessful, the system will make up to 8 attempts to send all reports to the secondary number. If still unsuccessful after the 16 attempts, the system displays the COMM. FAILURE message (FC for fixed-word displays). Primary Phone No. 2nd Phone No. 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All 4 = All except Open/Close, Test All 5 = All

50

Burglary Dialer Delay


Delay Time: 0 = no delay 1 = 15 seconds 2 = 30 seconds 3 = 45 seconds SIA-Compliant Controls: Delay Time: 1 = 15 seconds 2 = 30 seconds 3 = 45 seconds Delay Disable: 0 = use delay set in entry 1 1 = dial delay disabled for zones listed in zone list 6 (use zone list 6 to enter those zones that require dial delay to be disabled; these zones ignore the setting in entry 1)
UL: Dial delay plus entry delay must not exceed one minute; use zone list 6 to disable dial delay from appropriate zones, if necessary.
Delay Time

[2,0]
SIA-Compliant Controls: Delay Disable

Provides delay of BURGLARY ALARM report to the central station, which allows time for the subscriber to avoid a false alarm transmission. This delay does not apply to zone type 24 alarms (silent burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent as soon as they occur.
UL: Delay Time must be 0

SIA Guidelines: delay must be minimum of 15 seconds

53 54

SESCOA/Radionics Select
0 = Radionics (0-9, B-F) 1 = SESCOA (0-9 only reporting)

[0

Enter 0 for all non-SESCOA formats.


[0]

Dynamic Signaling Delay


0 = no delay (both signals sent) 1 = 15 secs 2 = 30 secs, etc.
UL: If using line security, must be 0. Reports will be sent to both the dialer and the communication device.

Select delay from 0 to 225 secs, in 15-sec increments. Intended for reporting via a communication device on the ECP bus (LRR). This field lets you select the time the panel should wait for acknowledgment from the first reporting destination (see 55) before it attempts to send a message to the second destination. Delays can be selected from 0 to 225 seconds, in 15-second increments. This delay is per message. If 0 is entered in this field, the control panel will send redundant reports to both Primary Dialer and LRR.
[0]

55

Dynamic Signaling Priority / AAV Path Select


0 = Primary Dialer first / AAV via phone line 1 = Communication Device (LRR) first / AAV via communication device path (see AAV Path Select paragraph at right)
For UL Commercial Burglary installations that use a DACT and LRR, this field must be 0.

This field selects the primary communication path for reporting (dialer or communication device) of primary phone number events (see 49 Split/Dual Reporting) and selects the communication path used for AAV sessions (phone line or communication device path). Use 29 IP/GSM menu mode to enable the communication device being used. For Dynamic Signaling Priority: Select the initial reporting destination for messages as follows: Primary Dialer First selected (0): If acknowledged before delay expires (see 54), then message will not be sent via LRR. If not acknowledged before delay expires, message is sent to both the Primary Phone No. and via LRR. Long Range Radio First selected (1): If acknowledged before delay expires, then message will not be sent to the primary dialer. If not acknowledged before delay expires, message is sent to both the Primary Phone No. and via LRR. For AAV Path Select: If using the UVS system or AVS system with non-ECP connection, option 0 must always be used. If using the AVS system with ECP connection, either option (0 or 1) may be used, but note the following: IMPORTANT: If option 1 is selected, a 2-way voice (AAV) device compatible with the communication device path must be used (ex. GSMV communicator). When selected, AAV sessions always occur via the GSMV communicator, even if reporting reverts to phone line backup due to GSMV communicator path reporting failure.

56, 57, 58 Menu Modes


These are Menu Mode commands, not data fields, for Zone Programming, Function Key Programming, and Expert Mode Zone Programming respectively. See page 3 and respective sections later in this document.

TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (59 thru 68, *70 thru 76, and 89): For 3+1 or 4+1 Standard Format: Enter a code in the first box: 19, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F. A 0 (not #+10) in the first box disables a report. A 0 (not #+10) in the second box results in advance to the next field. For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 19, 0, or BF, as described above. A 0 (not #+10) in the second box will eliminate the expanded message for that report. A 0 (not #+10) in both boxes will disable the report. For Ademco Contact ID Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).A 0 (not #+10) in the first box disables the report.
UL: Report codes are required in fields *61, *65, *71, *72, for UL Commercial Burglar Alarm installations. Report codes are required in fields *60, *62, *63, *64, *70, *73, *74, *75, *76, for UL Commercial Burglar Alarm installations and required for Residential Fire Alarm installations

SYSTEM STATUS REPORT CODES (59 68) Exit Error Alarm Report Code 59
See above for entries. SIA-Compliant Controls: [1] Always enabled.

[0]

After arming the system, entry/exit and interior zones remaining open after exit delay expires cause an alarm sound at the keypad and external sounder (keypad also displays EXIT ALARM), and entry delay begins. Disarming before the end of the entry delay stops the alarm sounding and no message is sent to the central station. The keypad will display CA (fixed-word) or ALARM CANCELED (alpha display). If the system is not disarmed before entry delay expires, an EXIT ALARM message (SIA-Compliant Controls: also zone alarm message) will be sent to the central station. The keypad will display EA (fixed-word ) or EXIT ALARM (alpha display), and alarm sounding continues until the system is disarmed (or timeout occurs). An Exit Alarm condition will also result if a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an EXIT ALARM message will be sent to the central station (except for SIA-Compliant Controls, see field *69 Recent Closing report). With

Contact ID format, the message will contain the zone number and error code 374 (ALARMEXIT ERROR).

60 61 62

Trouble Report Code


See above for entries.

[10]

Sent if a zone has a trouble condition.


See UL System Reporting Note above *59.

Bypass Report Code


See above for entries.

[00]

Sent when a zone is manually bypassed.


See UL System Reporting Note above *59.

AC Loss Report Code


See above for entries.

[10]

Timing of this report is random with up to a 4-hour delay. If AC restores before the report goes out, there is no AC LOSS report.
See UL System Reporting Note above *59.

63 64

Low Bat Report Code


See above for entries.

[10]

Sent when the systems backup battery has a low-battery condition.


See UL System Reporting Note above *59

Test Report Code


See above for entries. Periodic Test Report Scheduling Commands: installer code +[#] + [0] + 0 = report every 24 hrs installer code +[#] + [0] + 1 = report once per week installer code +[#] + [0] + 2 = report every 28 days

[00]

Sent periodically to test that the communicator and phone lines are operational. Frequency of report is set in Scheduling mode (event 11) or by the key commands listed at left: Each mode sets schedule 32 (FA168CPS) or schedule 08 (FA148CP) to the stated repeat option; first test report sent 12 hours after command.
See System Reporting UL Note above *59. NOTE: Make sure the Real-Time Clock is set to the proper time before entering the test report schedule command to ensure that test reports are sent when expected. (see Setting the Real-Time Clock section) [0,0,0]
Part. 1 Part. 2 Common

65

Open Report Code


See above for entries.

Sent upon disarming the system in the selected partitions.


See UL System Reporting Note above *59.

66

Arm Away/Stay Rpt Code


See above for entries.
Away Stay Part. 1 Away Stay Part. 2 Away Stay Common

[0,0,0,0,0,0]

This option allows for independent programming of Away and Stay reports for each partition, including the common lobby. NOTE: OPEN reports are not sent if the associated closing report is not enabled.

67 68

RF Trans. Low Bat Report Code


See above for entries.

[00]

Sent when a transmitter low-battery condition exists.


UL: must be enabled if wireless devices are used

Cancel Report Code


See above for entries. SIA-Compliant Controls: [10] Report enabled.

[00]

Sent upon disarming the system after an alarm condition was reported.

69

Recent Closing Report Code


Not applicable to FA148CP/FA168CPS See above for entries. SIA-Compliant Controls: Always enabled.

[11]

SIA-Compliant Controls: Field does not apply to other controls. Similar to the Exit Error condition described in field *59, but occurs if any burglary zone is faulted within two minutes after the initial exit delay expires. Disarming the system within the two minutes stops the alarm sound and displays "ALARM CANCELED " or "CA" and faulted zone number. No message is sent to the Central Monitoring Station. If the system is not disarmed within two minutes, the alarm sound continues and a recent closing and a zone alarm message are sent to the Central Monitoring Station (after dial delay expires).

RESTORE REPORT CODES (70 76) Alarm Restore Rpt Code 70


See above for entries.

[0]

Alarm restore signals indicate that respective alarm zone(s) are no longer faulted. Alarm restore reports are sent to the central station at bell timeout (field *33), if the zone(s) in alarm are actually restored to a non-faulted state at that time. Otherwise, alarm restore report(s) for respective alarm zones are sent when the system is disarmed.
See UL System Reporting Note above *59.

If Reports Per Armed Period Per Zone (*93) is also programmed, the system will report alarm and restore codes as described above until the Reports Per Armed Period count is reached. Disarming and rearming will reset the Reports Per Armed Period count.

71 72 73 74 75

Trouble Restore Rpt Code


See above for entries

[00]

Sent when a trouble in a zone is restored and code + OFF performed.


See UL System Reporting Note above *59.

Bypass Restore Rpt Code


See above for entries.

[00]

Sent when a zone that has been bypassed is unbypassed.


See UL System Reporting Note above *59.

AC Restore Rpt Code


See above for entries.

[00]

Sent after AC power has been restored after an AC power outage.


See UL System Reporting Note above *59.

Low Bat Restore Rpt Code


See above for entries.

[00]

Sent after a system low-battery condition is restored to normal.


See UL System Reporting Note above *59.

RF Trans. Lo Bat Rst Rpt Code


See above for entries.

[00]

Sent when a transmitters low battery condition is restored (i.e., new battery installed).
UL: must be enabled if wireless devices are used. See UL System Reporting Note above *59.

76

Test Restore Rpt Code


See above for entries.

[00]

This is sent when the Test mode is exited or upon timeout (4hrs).
See UL System Reporting Note above *59.

OUTPUT AND SYSTEM SETUP (77 93) Daylight Savings Time Start/End 77 Month
0 = Disabled 1-9 = January-September (1 = Jan, 2 = Feb, etc) #+10 = October #+11 = November #+12 = December

[3][11]

Enter the start and end month for daylight savings time, if applicable to the region.

78

Daylight Savings Time Start/End Weekend


0 = disabled 1 = first 2 = second 3 = third 4 = fourth 5 = last 6 = next to last 7 = third to last

[2][1]

Enter the start and end weekend for daylight savings time, if applicable to the region.

79, *80, *81, *82 Menu Modes


These are Menu Mode commands, not data fields, for Output Device Mapping, Output Programming, Zone List Programming, and Alpha Programming respectively. See page 3 and their respective sections for procedures.

84

Auto Stay Arm


0 = no 1 = partition 1 only 2 = partition 2 only 3 = both partitions

[FA168CPS: 3; FA148CP: 1]

If enabled, the system will automatically change AWAY mode to STAY mode if the entry/exit door is not opened and closed within the exit delay time after a user arms in AWAY mode from a wired keypad (nonRF device). An Opening report followed by an Armed Stay report is sent to the Central Station. If the door is opened and closed within the exit delay period, the system remains in AWAY mode. Any RF device that arms the system AWAY overrides this feature and the system remains armed AWAY.
#+12 = 8 min #+13 = 10 min #+14 = 12 min #+15 = 15 min [0]

85

Cross Zone Timer


0 = 15 secs 1 = 30 secs 2 = 45 secs 3 = 60 secs 4 = 90 secs 5 = 2 min 6 = 2-1/2 min 7 = 3 min 8 = 4 min 9 = 5 min #+10 = 6 min #+11 = 7 min

Sets the maximum amount of time in which two cross zones must be tripped in an armed system to send an alarm message to the Central Station. If only one cross zone is tripped during this time, a trouble message (CID code 380) for that zone is sent to the Central Station.
This option not for use in UL installations.

Assign cross zones on zone list 4, using *81 Menu mode. NOTE: Cross zoning takes effect only after Exit Delay expires.

86

Cancel Verify Keypad Display


0 = no alarm canceled display 1 = display Alarm Canceled when system is disarmed after an alarm has occurred. (To clear the ALARM CANCELED display, the user must enter the security code + OFF again.)

[1]

This feature causes a ALARM CANCELED display on the LCD keypad under the following conditions: After the kissoff of the cancel message to the Central Station, indicating a successful transmission. When an alarm is successfully canceled before the Central Station received the Alarm message. E.g., if an alarm is incorrectly triggered and the user presses code + OFF before the dial delay time has expired, the message will never go out to the CS. When the Cancel report is not enabled and the system is disarmed: a. before dialer delay expires (alarm report not sent) message Alarm Canceled is displayed. b. after dialer delay expires message Alarm Canceled is not displayed.
[0]

87

Misc. Fault Delay Time


0 = 15 secs 1 = 30 sec 2 = 45 secs 3 = 60 secs 4 = 90 secs 5 = 2 min 6 = 2-1/2 min 7 = 3 min 8 = 4 min 9 = 5 min #+10 = 6 min #+11 = 7 min #+12 = 8 min #+13 = 10 min #+14 = 12 min #+15 = 15 min

(used with Configurable Zone Types digit 6) Used with zones assigned to a configurable zone type with fault delay on (configurable zone type digit 6), and sets a zone response time of 15 seconds to 15 min. It can be assigned to zones with sensors that provide a trouble indication when an oil tank is low, or similar applications for critical condition monitoring where a non-alarm response is desired.
UL: may only be used on non-burglar alarm/ non-fire alarm zones when used in fire and/or UL burglar alarm installation

10

88

Program Mode Lockout Options


0 = standard *98 installer code lockout (reentry only by [] + [#] within 50 secs after power up) 1 = lockout [] + [#] reentry after *98 exit (reenter via installer code or downloader only) 2 = not applicable (option doesnt exist) 3 = lockout local programming after *98 exit (reenter by downloader only)

[0]

This table summarizes the Program Mode Lockout options:


Exit *88 Reentry By: Command Entry Installer Power-up *99 n/a yes yes *98 0 no yes *98 1 yes no *98 3 no no pressing [] + [#] within 50 seconds of power up Downloader yes yes yes yes

89

Event Log Full Report Code


See box above field *59 for report code entries.

[00]

If an Event Logging selection is made in field 90, a message can be sent to the central station receiver when the log is 80% full. If the log becomes full, new messages overwrite the oldest messages in the log.
[3]

90

Event Log Enables


0 = None 1 = Alarm/Alarm Restore 2 = Trouble/Trouble Restore 4 = Bypass/Bypass Restore 8 = Open/Close. Example: To select Alarm/Alarm Restore, and Open/Close, enter 9 (1 + 8); To select all, enter #15.

This system can record various events in a history log (FA168CPS = 100 events; FA148CP = 50 events). At any time, the downloader operator can then upload the log and view or print out all or selected categories of the log. The downloader operator can also clear the log. Event log can also be viewed at an alpha keypad. The display/printout at the central station will show the date, time, event, and description of the occurrences. Data Entry Example: To select Alarm/Alarm Restore and Open/Close, enter 9 (1+ 8); to select all events, enter #15. NOTE: System messages are logged when any non-zero entry is made.
[8, 0]
Options SIA-Compliant Controls: Call Wait Disable

91

Option Selection
0 = None 2 = Sounder Delay (delays sounding by 15 seconds) 1 = Bell Supervision Processing 4 = AAV 8 = Exit Delay Restart/Reset #+12 = AAV and Exit Delay Restart/Reset SIA-Compliant Controls: Options: Same as for FA148CP/FA148CPS. Call Waiting Disable: 0 = call waiting not used 1 = call waiting disable digits (*70) entered in field *40; (when selected, the system dials the entry in field *40 only on alternate dial attempts; this allows proper dialing in the event call waiting service is later canceled by the user).

Select the desired options by adding the values of each desired option. Sounder Delay: If enabled, delays external sounding by 15-seconds. IMPORTANT: AAV should not be used when Paging or Alarm Reports are sent to a secondary number unless the monitoring zone option is used (which pauses calls). Otherwise, the call to the secondary number by the communicator after the alarm report will prevent the AAV from taking control of the telephone line, and the AAV Listen in session cannot take place.
UL: must use ADEMCO UVCM module; Exit Delay Restart/Reset must be disabled UL: If Sounder Delay used, entry delay (*35) must be 30 sec. max. SIA Guidelines: Exit Delay should be enabled. If bell supervision is selected, you must also cut the red PCB Bell Supervision jumper. Exit Delay Restart/reset option allows use of the [] key to restart the exit delay at any time when the system is armed STAY or INSTANT. This feature also enables automatic exit delay reset, which resets exit delay if the entry/exit door is re-opened and closed before exit delay time expires after arming AWAY. Automatic Exit Delay Reset occurs only once during an armed AWAY period. [0,0] 1 2

92

Phone Line Monitor Enable


Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+15 = 15 min) Entry 2: 0 = Keypad display when line is faulted 1 = Keypad display plus keypad trouble sound. Each partition turns off its own trouble sound. No automatic timeout. 2 = Same as 1, plus programmed output device STARTS. If either partition is armed, external sounder activates also. External sounder will be turned off by normal bell timeout, or by security code plus OFF from either partition (it does not have to be the one that was armed).

Entry 1: Sets the length of time a phone line fault must remain after detected before the second digit option is activated. Entry 2: Selects the desired phone line fault response. Option 2 may be used even if a relay unit or Powerline carrier device is not connected to the control. Programmed Output Device must either be programmed to be STOPPED in field 80 or STOPPED by entry of [security code] + [#] + 8 + device number. Partition in 80 should be set to 0, for STOP.
UL: Field *92 must be enabled for fire alarm installations, UL commercial burglar alarm installations and UL residential burglar alarm installations. If the control unit is used on a UL commercial burglar alarm system which requires 2 methods of remote communication, then the control units DACT and the other method of signal transmission must monitor each other against communication failure and line fault. The fault must be received and annunciated within 200 seconds of its occurrence.

11

93

Reports In Armed Period Per Zone (Swinger Suppression)


Restrict Report Pairs: 0 = Unlimited Reports 1 = 1 report pair per zone per armed period 2 = 2 report pairs per zone per armed period SIA-Compliant Controls: Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs Unlimited Reports Enable: 0 = restrict reports to the setting in entry 1 1 = unlimited reports for zones listed in zone list 7; (use zone list 7 to enter those zones that require unlimited reporting; these zones ignore the setting in entry 1)

[1,0]
Restrict SIA-Compliant Controls: Report Pairs Unlimited Reports Enable

Selection limits the number of alarm/alarm restore message pairs per zone sent to the CS in an armed period. Swinger suppression applies to burglary zones only. SIA Guidelines: Must be set for option 1 or 2

DOWNLOAD INFORMATION (94, 95) Download Phone No. 94

Enter up to 20 digits, 09; #+11 for ''; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused spaces. If fewer than 20 digits, exit field by pressing . To clear entries from field, press 94.

Enter the phone number of the downloading computer.


UL: downloading may be performed only if a technician is at the site. Up/downloading via the Internet has not been evaluated by UL.

95

Ring Count For Downloading

0 = Disable Station Initiated Download; 114 = number of rings (19, # +10 =10, Refer to the chart below and program accordingly. answer down# +11 =11, # +12 =12, # +13 =13, phone module machine loading Set field 95 to # +14 =14); yes no no 1-14 (not 0) 15 = answering machine defeat yes yes no greater than rings set on answer machine (# +15 =15). (e.g., if ans. machine is 4 rings, set this NOTE: Do not enter 0 if using 4286 Phone Module.
field to 5). This allows access to the phone module if the answer machine is off. yes no yes 1-14 (not 0) yes yes yes 15 (bypasses answer machine) no no no 0 no yes no 0 no no yes 1-14 no yes yes 15 NOTE: If 15 is entered to bypass an answering machine, and a 4286 Phone Module is included in the system, you should note the following: When calling in from an off-premises phone, the user should make the initial call, allow 1 or 2 rings only, then hang up, then call again. The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible.

[15]

96, 97 98, 99

Initialize/Reset Defaults (These are commands, not data fields. See page 3.) Exit Commands (These are commands, not data fields. See page 3.)

PAGER OPTIONS (160- 172)


The system can send various reports to several pagers (FA168CPS = up to 4; FA148CP = up to 2). To program pager reporting, do the following: 1. Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171. 2. Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers). 3. Make sure appropriate user open/close pager reports are enabled (see Security Codes section in User Guide). Users that perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 2. 4. If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then select event type 03). System must be armed for the Latchkey report to be sent. 5. If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key (function 01). 6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each pager (zone lists 9-12).
FA148CP supports zone lists 9 and 10 only.

12

160

Pager 1 Phone No.


Enter up to 20 digits. 09 #+11 = '' #+12 = '#' #+13 = 2-second pause

If entering fewer than 20 digits, exit by pressing [] + next field number. To clear entries, press 160.

161

Pager 1 Characters
Enter the optional prefix characters, up to 16 digits. 09 #+11 = '' #+12 = '#' #+13 = 2-second pause

Up to 16 optional characters may be sent as a prefix to the 7-digit system status code sent to Pager #1 (if used). Phone number in field *160 must have been entered. If fewer than 16 characters, exit by pressing [] and next field number. To clear entries: press 161. The 16 characters may be composed of the following: PIN number, Subscriber account number, (enter # + 11 to send ), # (enter # + 12 to send #), Pause (enter # + 13 to allow a 2-second pause), special character(s) the user may decide to transmit Some paging systems require pause(s) before the prefix. The Pager format for the 7-digit status code is defined as follows: XXXYYYY where: XXX = 3-digit event code: 911 = Alarm, 811 = Trouble, 101 = Opening (disarm), 102 = Closing (arm AWAY) YYYY = 4-digit user or zone number (depending on type of event). The first digit indicates partition (0 = system, 1 = part 1, 2 = part 2, 3 = common), followed by the 3-digit user or zone number. Display Example 1. 9 1 1 1 0 0 4 Indicates an alarm (911) caused by a fault in zone 4 (0004) in part. 1. Display Example 2. 1 0 2 2 0 0 5 Indicates the system is reporting a closingsystem arming (102) by User 5 (0005) in partition 2.
[0,0,0] P1 P2 comm

162

Pager 1 Report Options


0= 1= 4= 5= no reports sent Opens/closes all users All alarms and troubles All alarms / troubles, and opens/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9, and opens/closes for all users

For each partition, select from the listed options. For users enabled for paging. Reports to pager only when arming (close)/disarming (open) from a keypad using a security code; autoarming/disarming, arming with assigned button, and keyswitch arming do not send pager messages.

163 164 165 166 167 168 169 170

Pager 2 Phone No.


See field 160 for entries.

If entering fewer than 20 digits, exit by pressing [] + next field number. To clear entries, press 163. | | | | | | | | | | | | | | | If fewer than 16 characters, exit by pressing [] and next field number. To clear entries, press 164.
[0,0,0] P1 P2 comm

Pager 2 Characters
See field 161 for entries.

Pager 2 Report Options


See field *162 for reporting options.

Pager 3 Phone No.


See field 160 for entries.

Pager 3 Characters
See field 161 for entries.

Select for each partition (use zone list 10 for options 12 or 13) | | | | | | | | | | | | | | | | | | | If entering fewer than 20 digits, exit by pressing [] + next field number. To clear entries, press 166 | | | | | | | | | | | | | | | If fewer than 16 characters, exit by pressing [] and next field number. To clear entries, press 167.
[0,0,0] P1 P2 comm

Pager 3 Report Options


See field *162 for reporting options.

Pager 4 Phone No.


See field 160 for entries.

Pager 4 Characters
See field 161 for entries.

Select for each partition (use zone list 11 for options 12 or 13). | | | | | | | | | | | | | | | | | | | If entering fewer than 20 digits, exit by pressing [] + next field number. To clear entries, press 169. | | | | | | | | | | | | | | | If fewer than 16 characters, exit by pressing [] and next field number. To clear entries, press 170.

13

171 172

Pager 4 Report Options


See field *162 for reporting options.

P1

[0,0,0] P2 comm

Select for each partition (use zone list 12 for options 12 or 13).
[3]

Pager Delay Option For Alarms


0 = none 1 = 1 minute 2 = 2 minutes 3 = 3 minutes

This field determines the delay of alarm reports to the pager. This gives the Central Station enough time to verify the alarm report it received before the dialer attempts to dial the pager. This delay is for ALL pagers in the system.

MISCELLANEOUS SYSTEM FIELDS (*174-*181)

174

Clean Me Reporting Options


0 = disable 1 = Clean Me signal reports

[0] For ESL smoke detectors

This is a maintenance feature for ESL 2-wire smoke detectors on Zone 1. If used, this option limits the number of smoke detectors to a maximum of 10, rather than 16. To enable the clean me feature, a time response setting of 3 (1.2 seconds) must be entered in 56 Zone Programming for zone 1. NOTE: If Clean Me is enabled, you must enter 3 in field 56 programming for zone 1 response time.
[0] [0] 1 2

177

Device Duration 1, 2
0 = 15 secs 1 = 30 secs 2 = 45 secs 3 = 60 secs 4 = 90 secs 5 = 2 min 6 = 2-1/2 min 7 = 3 min 8 = 4 min 9 = 5 min #+10 = 6 min #+11 = 7 min #+12 = 8 min #+13 = 10 min #+14 = 12 min #+15 = 15 min

(used in *80 Menu mode-Device Actions 5/6) These entries set the duration for output action options 5 (duration 1) and 6 (duration 2) programmed in 80 Output Function Programming.
[0]

181

50/60 Hertz AC Operation


0 = 60 Hz; 1 = 50 Hz

Select the type of AC power applied to the control (option is used for Real-Time Clock synchronization)

CONFIGURABLE ZONE TYPE OPTIONS (*182-*185)


(see Configurable Zone Type Worksheet) The system allows you to define custom zone types (FA168CPS supports 4 [types 90-93]; FA148CP supports 2 [types 90, 91]), based on the options described at right. All configurable zone types can be programmed via the downloader. Zone types 90-91 can also be programmed from a keypad using data fields *182-*185. IMPORTANT: Be careful when selecting combinations of options for configurable zone types. Contradictory options can cause unpredictable results. Configurable Zone Type Options Auto Restore (entry 2): Faults on zones set for this option are cleared; restore messages sent upon restoral of faults. Vent Zone (entry 2): Zones set for this option are ignored if faulted when arming the system, but are protected if the zone is later restored (e.g., an open window can be ignored when arming, but if the window is later closed, it will be protected; opening the window again causes an alarm.) Bypass Disarmed (entry 4): Zones set for this option can be bypassed only while the system is disarmed. Bypass Armed (entry 4): Zones set for this option can be bypassed when the system is armed. Dial Delay (entry 6): Alarms on zones set for this option participate in dial delay central station reporting, if system dial delay enabled in field *50. Fault Delay (entry 6): Faults on zones set for this option are delayed by the time set in field *87. Do not use this option if using entry/exit delay for this zone type. Faults Display (entry 7): Selects how faults on zones set for this zone type are displayed. Power Reset/Verification(entry 7): Selects whether the system resets power (when user enters code + OFF), and whether the system performs alarm verification (see description for zone type 16 in Zone Type Definitions section) when a fault occurs on these zones. Use Entry Delay (entry 8): Selects whether to use the systems entry delay times. Use Exit Delay (entry 8): Selects whether to use the systems exit delay time. Interior Type (entry 8): Zones set for this option are treated same as standard zone type 4 (bypasses when armed STAY, faults displayed). Alarm Sounds (entry 9): Selects the type of alarms sound for zones set for this zone type. Bell Timeout (entry 9): Alarm sounding on zones set for this option remain for the duration set in fields *32 / *33. Fire Zone (entry 9): Zones set for this option respond in the same manner as if programmed for zone type 9. Do not set fire zones to respond as a fault in entries 1-6. Trouble Sounds (entry 10): Selects the type of trouble sounds for zones set for this zone type (periodic beeps = once every 30 seconds; trouble beeps = rapid beeping). Chime Enable (entry 10): Zones set for this option cause a chime when Chime mode is on.

14

182

Configurable Zone Type 90


(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
1 2 3 4 5 6 7 8 9 10

Enter the appropriate value for each entry, 1-10, based on the charts provided in the Configurable Zone Type Worksheet section. Each entry is the sum of the values of its selected options To calculate the value for each entry, add the values of the selected options in each of the entrys columns shown in the respective chart (one option per column). For example, to program entry 2 for alarm response to short, auto restore on, but not a vent zone, enter 5 (1 for alarm short + 4 for auto restore-yes + 0 for vent zone-no).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.

183

Zone Type 90 Report Codes


90 ALARM ID: XXX TROUBLE ID: XXX Press [] when done to continue.

Enter the desired 3-digit Contact ID report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [] moves forward. NOTE: Zone alarm report codes and trouble report code (60) and relevant restore codes must be enabled in order to report configurable zone type codes. Important Notice on Report Codes: To avoid confusion at the central station, it is recommended that existing Contact ID codes be used with configurable zone types whenever possible. Check with the central station for a complete list of Contact ID report codes. If none of the codes are suitable, choose a code in the reserved range of 750-789 and make sure to define the code with your central station.
1 2 3 4 5 6 7 8 9 10

184

Configurable Zone Type 91


(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15) See 182 for entries.
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.

185 189

Zone Type 91 Report Codes


91 ALARM ID: XXX TROUBLE ID: XXX

See 183 for entries.

AUI Device Enables


(for Touch Screen Style Keypads) FA168CPS: Enter each touch screen keypads home partition 0 = disable 1 = partition 1 2 = partition 2 3 = partition 3 (common) FA148CP: 0 = disable 1 = enable
AUI 1 AUI 2 AUI 3 AUI 4

[1, 1, 0, 0]

System supports touch screen style keypads (e.g., Symphony Advanced User Interface, and 6270 Touch Screen Keypad; FA168CPS = up to 4; FA148CP = up to 2). NOTE: Use of touch screen style keypads does not affect the number of standard keypads supported. AUI Compatibility Note: To ensure proper AUI device operation, use AUI devices with the following rev levels: FA700KP series use version 1.0.9 or higher; 8132/8142 (Symphony) series use version 1.1.175 or higher. Touch Screen (AUI) device 1: Must set device address to 1 Touch Screen (AUI) device 2: Must set device address to 2 Touch Screen (AUI) device 3: Must set device address to 5 Touch Screen (AUI) device 4: Must set device address to 6

15

KEYPAD OPTIONS *190-*199


To enable keypads: 1. Set desired address at keypad (refer to keypads instructions for setting the address). 2. Use data fields *190-*196 to enable keypad addresses, assign a partition, enable sound options in field. 3. Use fields *197, *198, and *199 to turn on partition number display, exit time interval display, and select fail display mode. 4. Set keypad-related data fields as appropriate: *21 Quick Arm Enable, *23 Forced Bypass, *84 Auto STAY Arm NOTES: 1. Options for keypad 1, address 16, are set by the factory and cannot be changed. 2. Each keypad must be assigned a unique address. Keypads programmed with the same address will give unpredictable results.

190

Keypad 2 Device Address 17


Partition/ Enable: FA168CPS: Enter partition where: 0 = keypad disabled 1-3 = part. no. (3 = common) FA148CP: 0 = disable 1 = enable Sound: 0 = no suppression 1 = suppress arm/disarm and Entry/Exit beeps 2 = Suppress chime beeps only 3 = suppress arm/disarm, Entry/Exit, and chime beeps
Partition/ Enable Sound

[0] [0]

Partion/Enable: For FA168CPS, enter the partition in which the keypad is located; for FA148CP, enter 1 to enable, or 0 to disable the keypad. Sound: Enter the desired sound option for this keypad.

191 192 193 194 195 196 197

Keypad 3 Device Address 18


See field 190 for entries.
Part/Enable Sound

[0] [0]

Keypad 4 Device Address 19


See field 190 for entries.
Part/Enable Sound

[0] [0]

Keypad 5 Device Address 20


See field 190 for entries.
Part/Enable Sound

[0] [0]

Keypad 6 Device Address 21


See field 190 for entries.
Part/Enable Sound

[0] [0]

Keypad 7 Device Address 22


See field 190 for entries.
Part/Enable Sound

[0] [0]

Keypad 8 Device Address 23


See field 190 for entries.
Part/Enable Sound

[0] [0]

Exit Time Display Interval


0 = no display 1-5 = seconds between display refresh

[0]

If enabled, keypads display the exit time remaining after arming the system, updated at the interval selected (i.e. if the exit delay is 30 seconds and 2 is selected in this field, the keypad display refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.). An interval greater than 1 may be necessary for some older keypads to allow users time to enter key presses between display updates. NOTE: If enabled and using only 2-digit fixed-word keypads (e.g., FA245RF), do not set exit delay time greater than 96 seconds. Using a longer delay time may cause end-user confusion because 2-digit display keypads cannot display times greater than 99. If longer exit time is required by the installation, it is recommended that the Exit Time Display option be disabled (0). TOUCH SCREEN DEVICE NOTE: If using more than one touch screen device (e.g., FA700KP, Symphony) with the system, leave field *197 Exit Time Display Interval set to the default value 0. The FA700KP automatically displays remaining exit time in one-second increments.
[0]

198 199

Display Partition Number


0 = no 1 = yes (partition no. displayed)

(FA168CPS; for Alpha Display Keypads) If selected, the partition number is displayed in the upper-left corner of the display. This is useful when using the GOTO partition function.
[0]

ECP Fail Display


0 = 3-digit display 1 + device address) 1 = 2-digit fixed-display as 91

Select 0 if using Alpha keypads and/or 3-digit Fixed-Word Display keypads. ECP faults will display 1 plus the device address (00-30) of device causing the fault (e.g., faults on device 07 display as 107). Select 1 if using 2-digit Fixed-Word Display keypads (e.g., certain 6128 series keypads). If selected, ECP faults for all devices will display as 91 on 2-digit displays, and 191 on 3-digit or Alpha keypads.

16

CONFIGURABLE ZONE TYPES WORKSHEETS


Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below. Use fields *183 and *185 to program Contact ID report codes for these zone types.
ENTRY 1
(See note 5 for RF zones)

ENTRY 2

(See note 5 for RF zones)

Entries for Fields *182 and *184


Vent Zone Entry Zone Type 90 (field *182) 1 2 3 4 5 6 7 8 9 10 Zone Type 91 (field *184)

Response when system disarmed and zone is: Intact EOL Open Shorted
RF zone normal RF zone N/A RF zn off-normal

Auto Restore

0 = normal 0 = normal 1 = alarm 4 = alarm 2 = trouble 8 = trouble 3 = fault 12 = fault Entry 1 = EOL + Open

0 = normal 0 = no 0 = no 1 = alarm 4 = yes 8 = yes 2 = trouble 3 = fault Entry 2 = Short + auto restore + vent zone

ENTRY 3

(See note 5 for RF zones)

ENTRY 4

(See note 5 for RF zones)

Response when armed STAY and zone is: Intact EOL Open Shorted
RF zone normal RF zone N/A RF zn off-normal

Byp. when disarmed

Byp. when armed

0 = normal 0 = normal 1 = alarm 4 = alarm 2 = trouble 8 = trouble 3 = fault 12 = fault Entry 3 = EOL + Open

0 = normal 0 = no 0 = no 1 = alarm 4 = yes 8 = yes 2 = trouble 3 = fault Entry 4 = Short + byp. disarmed + byp. armed

ENTRY 5

(See note 5 for RF zones)

ENTRY 6

(See note 5 for RF zones)

Response when armed AWAY and zone is: Intact EOL Open Shorted
RF zone normal RF zone N/A RF zn off-normal

Dial Delay (see field *50)

Fault Delay (see field *87)

To calculate the value for each entry: Simply add the values of the selected options in each of the entrys columns (one option per column). For example, to program Entry 2 for alarm response to short, auto restore on, but not a vent zone, enter 5 (1 for alarm short + 4 for auto restore yes + 0 for vent zone no).

0 = normal 0 = normal 1 = alarm 4 = alarm 2 = trouble 8 = trouble 3 = fault 12 = fault Entry 5 = EOL + Open

0 = normal 0 = no 0 = no 1 = alarm 4 = use delay 8 = use delay 2 = trouble 3 = fault see note 1 Entry 6 = Short + dial delay + fault delay

ENTRY 7
Display Faults

ENTRY 8
Use Exit Delay 0 = no 4 = use exit delay Respond as Interior Type 0 = no 8 = yes see note 2

INTACT EOL

OPEN

SHORTED
ZONE-003-V0

Power Reset/ Use Entry Verification Delay 1/2 0 = no 0 = show alarms 0 = no 1 = delay 1 when armed 4 = power reset 2 = delay 2 & disarmed after fault (by code + OFF) 1 = dont show alarms when 12 = verification (see zone armed (show type 16) alarms, trbles,
faults when disarmed)

Zone Conditions Represented in Entries 1-6 NOTES: 1. Do not use the fault delay option with a configurable zone type if it is set for an entry or exit delay, otherwise unpredictable results may occur. 2. To create an interior type zone, select respond as interior zone type (entry 8, interior type = yes), and set zone response to fault in entries 3-4 to ensure fault displays; do not set as normal, alarm, or trouble. 3. Do not set fire zones to respond as a fault (entries 1-6), otherwise faults will not display unless the [] key is pressed. 4. 4219/4229 modules must use EOLRs or unpredictable results may occur. 5. RF Zones: The open option in entries 1, 3, and 5 is not applicable for RF zones. Use the intact EOL option for normal RF zone conditions and shorted for offnormal RF zone conditions. 6. a. Zone-Doubling/Double-Balanced: A short on either zone of a zone-doubled pair or on a double-balanced zone causes a tamper condition. b. For double-balanced zones, this entry must be 0. c. For zone-doubled zones, both zones of the doubled pair must be assigned the same response to a short.

3 = never show any alarms, trbles, faults Entry 7 = fault display + power reset/verification

Entry 8 = entry delay 1/entry delay 2 + exit delay + interior zone type

ENTRY 9
Alarm Sounds Use Bell Timeout 0 = no 4 = yes Respond as Fire Zone 0 = no 8 = yes

ENTRY 10
Trouble Sounds 0 = none 1 = periodic beep 2 = trouble beeps Chime when Chime Mode On 0 = no 4 = yes

0 = none 1 = steady keypad 2 = steady bell see fields *32, see zone type and keypad *33 09; see note 4 3 = pulsing bell and keypad Entry 9 = alarm sounds + bell timeout + fire zone

Entry 10 = trouble sounds + chime

17

56 ZONE PROGRAMMING MENU MODE


(press *56 while in Program mode) The Zone Programming Worksheet is on page 36.

Zones and Partitions

Each protection zone needs to be programmed with various attributes using *56 Zone Programming mode or 58 Expert Programming Mode. Using this mode, enter the zone number to be programmed and make appropriate entries at the prompts. Finally, Confirm the serial number of wireless transmitter zones. The FA168CPS system can control two independent areas of protection (known as partitions) for use by independent users, if desired, by simply assigning zones to one or the other partition during zone programming. The FA168CPS, by default, automatically distributes users between the two partitions. The master user can change the user number distributions. Zones can also be assigned to a common partition, which is an area shared by users of both partitions (such as a lobby in a building). This allows either partition to arm, while leaving the common partition disarmed for access into the other partition. The following describes the functioning of the FA168CPS common partition: The common zone sounds and reports alarms only when both partitions are armed. If only one partition is armed, the system ignores faults on the common zone. Either partition may arm its system if the common zone is faulted, but once armed, the other partition will not be able to arm unless the common zone is first bypassed or the fault is corrected. Faults on the common zone are displayed on common zone keypads, and will also appear on another partitions keypad when that partition is armed. Either partition can clear and restore the common zone after an alarm.

56 Menu Mode PROMPT


SET TO CONFIRM? 0 = NO 1 = YES 0

VALID ENTRIES Confirm? 0 = no 1 = yes [] to continue Zone Number


FA168CPS: wired 01-08 (and 09-48); wireless 09-48; RF button zones 49-64 FA148CP: wired 01-06 (and 07-22); wireless 09-34; RF button zones 49-56 Both Controls: 91 = addr. device report enable 92 = duress report enable 95, 96, 99 =emerg. zones [] to continue 00 to quit

EXPLANATION
This display appears upon entry into this mode. The default is 0 (No). If 1 (Yes) is entered, you will be prompted to confirm each transmitter after entering the serial and loop numbers (at the XMIT TO CONFIRM prompt later). Enter the zone number that you wish to program. Zone 10 has been entered in the example display at left. Enter a report code for zone 91 to enable addressable device reporting. Enter a report code for zone 92 to enable duress reporting. 95, 96, 99 are emergency (panic) key zones. if zone expanders are used.

Enter Zn Num. (00 = Quit) 10

Zn ZT P RC In: L 10 00 1 10 RF: 1

Summary Screen
[] to continue

10 Zone Type Perimeter

Zone Type (ZT)


03 See table at right.

IN: L appears for wireless zones and indicates input type and loop. IN: AD appears for hardwire expansion zones (AW) and indicates the modules address (AD), which is based on the zone number. HW: RT appears for hardwire zones and indicates configuration (EOL, NO, NC, zone doubling, double-balanced) and response time selection. Each zone must be assigned to a zone type, which defines the way in which the system responds to faults in that zone. Enter the Zone Type code from the list below: Note: If 00 is entered, Delete Zone ? will be displayed.
00 = Not used 01 = Entry/exit #1 02 = Entry/exit #2 03 = Perimeter 04 = Interior Follower 05 = Day/Night 06 = 24-Hr Silent 07 = 24-Hr Audible 08 = 24-Hr Aux 09 = Fire 10 = Interior w/Delay 12 = Monitor Zone 14 = Carbon Monoxide 16 = Fire w/Verify 20 = ArmSTAY* 21 = ArmAWAY* 22 = Disarm* 23 = No Alarm Resp 24 = Silent Burglary 77 = Keyswitch 81 = AAV Mon. Zone

*5800 button-type transmitters only

10 Partition 1

Partition No. (P)


(FA168CPS) 1-3 = partition (3 = common) [] to continue

Enter the Partition number for this zone. Partition 1 is shown entered.

18

10 Report Code 1st 01 2nd 00

Report Code (RC)


10 First Digit: 1-9, 10 for 0, 11 for
B, 12 for C, 13 for D, 14 for E, 15 for F

00 to disable Second Digit: same as above [] to continue


02 HARDWIRE TYPE EOL 0

Enter the report code for this zone, which consists of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. For example, for a report code of 10, enter 01 and 00. For Contact ID, entering any non-zero entry as the first digit enables the report code for this zone.

Hardwire Type
0 = EOL 1 = NC 2 = NO 3 = zone doubling (ZD) ; 4 = double-balanced (DB) [] to continue

This prompt appears only for zone numbers 02-08. Zone 1 is automatically set for EOL operation. FA168CPS

02 Response Time 1

Response Time (RT)


0 = 10mSec; 1 = 350mSec 2 = 700mSec 3 = 1.2 seconds [] to continue

Appears only for hardwire zones 01-08 (zone 02 is the display shown). Option 3: used for clean me option on zone 1 (see field 174). NOTE: If zone doubling is being used, the response time selected for zones 02-08 automatically applies to each zones associated doubled zone. This prompt is skipped for zones 2-8, or 2-16 if zone-doubling was enabled at Hardwire Type prompt. All of the RF transmitters have one or more unique factoryassigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). RF Transmitters can be enrolled as one of the following types: Type Description Sends periodic check-in signals, as well as RF (Supervised RF) fault, restore, and low-battery signals. The trans. must stay within receiver's range. Sends all the signals that the RF type UR (Unsupervised RF) does, but the control does not supervise the check-in signals. The transmitter may therefore be carried off-premises. Sends only fault signals. It will not send a BR (Unsupervised low-battery signal until it is activated. The Button RF) transmitter may be carried off-premises. NOTE: For the built-in hardwired zones, the Input Device type is automatically displayed as HW and cannot be edited. To change the input type of a previously programmed wireless device (type RF, UR, BR) to a wired zone (type AW), you must first delete transmitters serial number (see To Delete A Serial Number prompt) Enroll the transmitters serial number and loop number as follows: 1. a. Transmit two open/close sequences (for button-type trans, press and release the button twice, waiting about 4 secs before pressing the button the second time). OR b. Manually enter the 7-digit serial number printed on the label of the transmitter. Press the [] key to move to the L position, then enter the loop number. Use the [A] (Advance) and [B] (Back) keys to move the cursor forward and back within the screen. Pressing the [C] (Copy) key will insert the previously enrolled serial number, if desired (used when programming a transmitter with several input loops). To delete an existing serial number, enter 0 in the loop number field. The serial number will change to 0's. If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display. 2. Press [] to continue. The system now checks for a duplicate serial/loop number. If no duplicate is found, the display shows the serial number and loop number. 3. Press [] to continue to confirmation screen.

10 INPUT TYPE RF TRANS 3

Input Device type (In)


2 = AW (Aux wired zone) 3 = RF (supervised RF transmitter 4 = UR (unsupervised RF transmitter) 5 = Button type RF transmitter (unsupervised). [] to continue

10 INPUT S/N: L A022-4064 1

Input Serial number and Loop Number


[] to continue Used only when enrolling wireless transmitters.

19

10 INPUT S/N A022-4064

L ?

Loop Number Change


[] to continue

XMIT TO CONFIRM PRESS TO SKIP

Confirmation Option
[] to continue

Entd A022-4063 1 Rcvd A022-4064 1

If Serial or Loop Numbers do not match after activating the transmitter


[] to continue

10 INPUT S/N: A000-0000

L 0

To Delete a Serial No.


0 = delete serial number # = undo deletion [] to continue

NOTE: If the [C] key is used to copy the previously enrolled serial number, the cursor will move to the Loop column (L) with the previous serial number displayed, and display a highlighted question mark for the loop number. Enter the loop number and press []. The system will now check for a duplicate serial/loop number combination. This prompt will only appear if you answered Yes at the first prompt in this section. The system will enter a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. If the serial number transmitted does not match the serial number entered, a display similar to the one shown appears. If the loop number does not match, it will also be displayed. If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter (or transmit) the correct serial number. To delete an existing serial number, enter 0 in the loop number field. The serial number will change to 0's. If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display. If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and a summary display will appear, showing that zone's programming. Note that an s indicates that a transmitters serial number has been enrolled. Press [] to accept the zone information and continue. If you want to program descriptors for zones now, enter 1 (Yes) and refer to the 82 Descriptor Programming section for available descriptors. If 0 (No) was entered above, the system will return you to the ENTER ZN NUM. prompt for the next zone. When all zones have been programmed, enter 00 to quit

Zn ZT RC In: L 10 03 10 RF: 1s

Summary Screen
[] to continue

PROGRAM ALPHA? 0 = NO 1 = YES 0

Alpha Descriptors
0 = no 1 = yes [] to continue

E N TE R Z N N U M. ( 0 0 = Q U I T) 1 1

Next Zone Number


[] to continue; 00 = quit

Completing Zone Programming


When you have finished programming all zones, test each zone using the systems TEST mode. Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop.

58 EXPERT ZONE PROGRAM MODE


(press 58 while in Data Programming mode) This method is designed for use by installers with previous experience in programming First Alert Professional control panels. This mode is also used to program wireless keys using pre-defined templates. SET TO CONFIRM? 0 = NO 1 = YES 0

Confirm?
0 = no; 1 = yes; [] to continue

Zn ZT P RC HW: RT 01 09 1 10 EL 1

Summary Screen
01-64 = zone number; [] to continue; 00 = quit [D] to go to prompts for wireless key programming templates

Select whether you want confirmation of wireless device enrollment. (See XMIT TO CONFIRM prompt later in this section.) We recommend that you confirm the programming of every transmitter. If 1 (Yes) is entered, you will be prompted to confirm each transmitter after entering the serial and loop numbers (at the XMIT TO CONFIRM prompt later). A summary screen appears, showing zone 1s currently programmed values. Enter the zone number being programmed, then press [], which displays a summary screen for that zone and the cursor moves to the Zone Type location. The cursor then automatically moves to the next locations after each entry is made. If programming a wireless key, press the [D] key then skip to the Wireless Key Programming Templates section following this section. When [D] is pressed, you can choose from a series of preset templates for easy programming of wireless key zones. When all zones have been programmed, press 00 at this prompt to quit this menu mode.

20

Zn ZT P RC IN: L 10 00 1 10 RF 1

Zone Programming
ZT = see Zone Type chart shown in *56 Menu Mode Zone Type prompt P = partition 1, 2, 3 (common); RC = 1 (send CID report); 0 (no report) IN = input type; L = loop number [] to continue

A summary screen with the selected zones current programming appears. Begin programming zone information as follows: Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9 only; use *56 mode to enter hex codes), and Input Device Type (IN)* sequentially, but not the Loop No. (L). Use the [A] (Advance) and [B] (Back) keys on the keypad to move the cursor within the screen. Use the [C] key to copy the previous zones attributes. Press [] to save the programming and continue to the serial number/loop number prompt. If needed, you can press the [#] key to back up without saving. * If HW (hardwired) or AW (Auxiliary) is entered for Input Device Type, the next screen will be similar to the prompt shown, except that HW or AW will be displayed under IN. If RF, BR, or UR is entered, a prompt for Serial and Loop number will be displayed, as described in 56 Menu mode section. When done, the display returns to the initial summary screen prompt to let you program the next zone. To exit this mode, enter 00 at the Summary Screen prompt.

WIRELESS KEY PROGRAMMING TEMPLATES


(press the [D] key from *58 Menu mode Summary Screen) This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see System Operation section, Assigning Attributes Command in the User Guide). TEMPLATE ? 16

Template Number
1

13 = 5804 templates; 46 = 5804BD templates

Enter Template number 16 (see chart on next page). See the defaults provided for each template in the chart that follows these procedures. Select from templates. Press [] to display template (1 shown selected). NOTE: If necessary, press [#] to back up and re-enter template number. Press [#] if you want to return to *58 Menu mode summary screen. When [] is pressed, the selected template will be displayed. Top line of display represents loop numbers; bottom line represents zone type assigned for each loop. Press [] to accept template. Enter the partition in which the key is to be active, then press [] to continue. The system will search for the highest available consecutive 4-zone group (the four zones in the case of the 5804 and 5804BD), and display the lowest zone number of the group. If you want to start at a different zone, enter the zone desired, and press []. If that zone number is displayed, the system has the required number of consecutive zones available, beginning with the zone you entered. If not, the system will again display a suggested zone that can be used. If the required number of consecutive zones is not available at all, the system will display 00. To quit this mode and return to *58 Menu mode, enter 00 at this prompt. Press [] to accept. Manually enter the serial number printed on the label for the wireless key or press and release the button to transmit its serial number. Press [] to accept the serial number. The system will check for a duplicate. If necessary, press the [#] key to back up without saving, and re-enter the serial number. Use the [A] key to move forward within the screen, and the [B] key to move backward.

L T

01 23

02 22

03 04 21 23

Template Display

PARTITION 1
ENTER START ZONE

Partition
FA168CPS. 1 = partition 1; 2 = partition 2

Start Zone Number

00 = QUIT

36

INPUT S/N AXXX-XXXX

Serial Number

21

XMIT TO CONFIRM PRESS TO SKIP

Confirm
[] to continue

If Yes was entered at the SET TO CONFIRM? prompt previously (see first prompt following entry into the 58 Expert Programming Mode), the display on the left will appear. Confirm serial and loop numbers by activating the wireless key.

Entd A022-4063 Rcvd A022-4064

Not Confirmed
[] to continue

IMPORTANT: When confirmed, the key is not active for arming/disarming until it is assigned to a user number (using the assigning attributes command, attribute 4). See System Operation section for procedure. If the serial number transmitted does not match the serial number entered, a display similar to the one shown will appear. If the loop number does not match, it will also be displayed. If so, activate the button on the wireless key once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key and then enter the correct serial number. If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and will return you to the Zone Number prompt to enter the starting zone for the next wireless key. Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt. NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the device and affix it in the appropriate column on the ZONE PROGRAMMING worksheet of the Programming Form; then enter the other information (zone number, zone type, loop number, etc.) relevant to that device.

Wireless Key Predefined Default Templates


LOOP 3
GREEN/YELLOW LED LOOP 2

YOU MUST PROGRAM THIS BUTTON LOOP 4

ON

OFF

LOOP 2 LOOP 1

Note: These transmitters are not intended for use in UL installations.

RED/YELLOW LED

LOOP 4 (YOU MUST PROGRAM THIS BUTTON)

LOOP 3

LOOP 1

ENROLL AS "BR"
5804-001-V1

ENROLL AS "BR"

5804 Wireless Key Transmitter


For 5804 Loop Function 1 No Response 2 Disarm 3 Arm Away 4 No Response Loop Function 1 No Response 2 Disarm 3 Arm Away 4 Arm Stay Loop Function 1 24-hour audible 2 Disarm 3 Arm Away 4 Arm Stay

5804BD 2-Way Wireless Key Transmitter


Zone Type 23 22 21 23 Zone Type 23 22 21 20 Zone Type 7 22 21 20 TEMPLATE 4 For 5804BD Loop Function 1 No Response 2 No Response 3 Arm Away 4 Disarm Loop Function 1 No Response 2 Arm Stay 3 Arm Away 4 Disarm Loop Function 1 24-hour audible 2 Arm Stay 3 Arm Away 4 Disarm Zone Type 23 23 21 22 Zone Type 23 20 21 22 Zone Type 7 20 21 22

TEMPLATE 1

TEMPLATE 2

TEMPLATE 5

TEMPLATE 3

TEMPLATE 6

22


5804BD-007-V0

57 FUNCTION KEY PROGRAMMING MENU MODE


(press 57 while in Data Programming mode). The system provides the ability to program each of the four keypad function keys to perform one of 12 system operations. The end user can then activate the function by simply pressing and holding the programmed key for 2 seconds. Typical functions (listed below) include single-button arming, turning lights on/off, or single-button paging. To assign emergency key functions (function key option 00), first program the respective emergency zone number (95 for A key, 96 for C key, 99 for B key) with the desired zone type using 56 (or 58) Zone Programming mode, then use 57 Function Key menu mode to assign the desired key. To use a function key to activate a relay action (57 Menu mode key function 07), use 79 Menu mode to map the output, and use 80 Menu mode to define the outputs action; select system operation type 66. To use a function key for a user macro, use 57 menu mode to activate the desired key, then define the actual macro functions using the user code + [#] + [6] [6] command. Press Key to Pgm 0 = Quit 0

Function Key
Press the desired function key, A-D. [] to continue 0 = Exit this mode

Press the desired function key (A-D) you want to program. NOTE: A key programmed as a function key is no longer available to be used as an end-user macro key or panic key.

A B C D

1 4 7

OFF

2 5 8 0

AWAY

3 6 9 #

STAY

MAX

TEST

BYPASS
keypad_keys-00-001-V0

INSTANT

CODE

CHECK

READY

Partition 1

Partition Number (FA168CPS)


1 = partition 1 2 = partition 2 3 = common partition [] to continue

Enter the partition in which the function key is active.

Key "A" Func Zone 95

Define Key Function


00 00-12 = see list at right [] to continue; returns to key number prompt with the next function key letter displayed

Enter the desired function for this key, 00 to 12, from the options listed. (00 selected for example display shown at left). Press [] to returns to key number prompt with the next function key letter displayed.
00 = For the Function key selected, the functions are predefined as follows: If A selected = Zone 95 (emergency key, same as [1] [] pair) If B selected = Zone 99 (emergency key, same as [] [#] pair) If C selected = Zone 96 (emergency key, same as [3] [#] pair) If D selected = Single-button paging 01 = Single-button paging (sends a 999-9999 message to pager) 02 = Display time 03 = Arm AWAY (reports as User 00 if closing reports are enabled) 04 = Arm STAY (reports as User 00 if closing reports are enabled) 05 = Arm NIGHT-STAY (reports as User 00 if closing reports enabled) 06 = Step Arming (arms STAY, then NIGHT-STAY, then AWAY) 07 = Output Device Command (for device programmed as system operation type 66function key in *80 Menu Mode) 08 = Communication Test (sends Contact ID code 601) 09 = Macro Key 1 (define macro by user code + [#] [6] [6] command) 10 = Macro Key 2 (define macro by user code + [#] [6] [6] command) 11 = Macro Key 3 (define macro by user code + [#] [6] [6] command) 12 = Macro Key 4 (define macro by user code + [#] [6] [6] command) System defaults to these function key settings. Macros 11-12 apply to FA168CPS only. If Night-Stay zones are listed in zone list 5

23

OUTPUT DEVICE PROGRAMMING GENERAL INFORMATION (*79/*80 Menu Mode)


Output Devices: The FA168CPS system supports up to 16 relays and/or Powerline Carrier devices (X-10 devices) plus 2 built-in trigger outputs in any combination. These 18 outputs are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to assign output numbers and map them to device addresses. The FA148CP supports 8 relays and 2 built-in trigger outputs (total 10 outputs). The system also provides installer-defined output functions, which can be assigned to any of the physical outputs. Therefore, the action of any one of the outputs can be based on as many of these defined functions as desired. This lets a single relay or X-10 device perform many functions. The control supports: FA168CPS = up to 48 defined functions; FA148CP = up to 24 functions Use *80 Menu Mode to define output functions. WARNING: Relays and output devices are not recommended for life safety applications. NOTE: When navigating the *79 and *80 menus: The [] key is used to accept an entry and advance to the next prompt. The [#] key is used to revert back to the last question to check or change an entry. Press [] to go forward again.

Output Functions:

Programming Output Devices


1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses. NOTE: You must map output devices using *79 Menu Mode before you can use *80 menu Mode. 2. Use *80 Menu Mode to create output definitions, which control the output devices, if desired. 3. Use *81 Zone List Menu mode to define zone lists for use with output devices if the device action is based on more than one zone. To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for scheduled automatic activation, simply map the device using *79 Menu mode. To program a device to automatically activate upon a system event (or function key), use *79 Menu mode to map the device, then use *80 Menu mode to define the automated device action.

79 RELAY/POWERLINE CARRRIER DEVICE (X-10) PROGRAMMING MENU MODE


(press 79 while in Programming mode) The *79 Device Mapping Worksheet is on page Error! Bookmark not defined.. Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline Carrier unit numbers. The system is based on predefined module addresses for 4204 and 4229 modules. Refer to the table shown at the Module Address prompt on the next page and set the modules addresses (via module DIP switches) accordingly. The following table shows how these outputs are identified.

Output Identification
This output Relays X-10 Device Built-in Outputs
ENTER OUTPUT NO. 00 = QUIT xx

is identified by the Relay Modules device address and the relay position on that module (i.e. the physical relay number, 1-4, on that module). a house ID (entered in data field *27) and the unit number of the device. the output number assigned, 17 for Trigger 1 and/or 18 for Trigger 2.

Device Output Number


FA168CPS: 01-16 = relays/X-10 17, 18 = on-board triggers FA148CP: 01-08 = relays/X-10 17, 18 = on-board triggers [] to continue 00 to quit

This is the logical (or reference) relay number as used in the system. Relays and X-10 devices are numbered 01-16; the onboard triggers are numbered 17 and 18 and can be programmed for inverted output, if required.

17 OUT NORM LOW 0 = NO 1 = YES 0

Output Normally Low


0 = no (standard default) 1 = yes [] to continue

(prompt appears only for Triggers 17 and 18) Selecting 0 (no) sets the output level normally high (default setting). Selecting 1 (yes) sets the output normally low. Output Trigger 17 can be used for resetting 4-wire smoke detectors by connecting it to the negative power terminal of the smoke detector, selecting 1 at this prompt, and setting as zone type 54, fire zone reset, in *80 Menu mode. After entry, display returns to Output Number prompt. Use *80 Menu mode to program the function of the trigger.

24

XX OUTPUT TYPE DELETE 0

Output Type
0 = delete 1 = relay on 4204/4229 module 2 = Powerline Carrier device (X-10) [] to continue

Select whether this is a relay or a Powerline Carrier (X-10) device. If Powerline Carrier is selected, go to A prompt. If relay is selected, skip to B prompt.

A
XX UNIT No. yy

Unit Number
01-16 = predefined address [] to continue

(prompt appears if X-10 is selected) Enter the unit code (set at the device) and press []. The system returns to the Output Number prompt. (prompt appears if relay is selected) Enter the predefined address for this module as listed below. Make sure the modules DIP switches are set to the selected address. Module Addresses
Address Module 07 1st 4229 (with zones 09-16) 08 2nd 4229 (with zones 17-24) 09 3rd 4229 (with zones 25-32) 10 4th 4229 (with zones 33-40) 11 5th 4229 (with zones 41-48) 12 1st 4204 13 2nd 4204 14 3rd 4204 15 4th 4204 These addresses apply to FA168CPS only.

B
XX MODULE ADDR 07-15 yy

Module Address
07-15 = predefined address [] to continue

XX REL POSITION 1-4 zz

Relay Position
1-4 = relay position [] to continue

This is the actual (or physical) relay number with respect to the Relay Module upon which it is located. For 4204 modules, relay numbers are 1-4. For 4229 modules, relay numbers are 1-2. The system returns to the Output Number prompt for programming the next device.

80 OUTPUT FUNCTION MENU MODE


(press 80 while in Programming mode) The Output Definition Worksheet is on page Error! Bookmark not defined.. Use this mode to program output function definitions (up to 48 functions) that provide automated control of any of the output devices, based on events occurring on individual zones or zones with certain zone types. Each output definition is identified by an output function number, and includes the following components:

Output Definition Components


Component Output Function No. Activated By Event Partition Output Action Output No. Description A reference number that defines an outputs characteristics. Determines whether the initiating event occurs on a zone, a zone list, or a zone type. Event that triggers the output action. Can be an event occurring on a specific zone number or a zone list, or a specific zone type. If the output is activated by zone type, this defines the partition in which the programmed event is to cause the device action. Defines the action of the relay/X-10 device when the defined event occurs. Can close for 2 seconds, stay closed until reset, continuously pulse (1-second close-open-close-open, etc.), toggle the device state, or activate for a defined duration (set in data field *177). Assigns this function to a specific output number (defined in *79 Menu Mode). This is the output number that will perform this function upon the triggering event. Note that each defined function is associated with only one output number. This means that if more than one output device needs to perform this particular function, you need to define another output function number with the same attributes, but assign the appropriate output number. (i.e. output devices can be assigned more than one function number, but each function number can only be assigned a single output number.

For example, if you want to pulse a strobe light upon fire alarms on zone 4 using a relay mapped to output number 2 (as programmed in *79 Menu Mode), program the following in *80 Menu Mode: Prompt Entry Output Funct. # = 01 (assuming this is the first output function) Activated By: = 3 (zone number) Enter Zn No. = 04 (requires 2-digit zone numbers) Output Action = 3 (continuous pulse) Output Number = 02 (device mapped in *79 Menu Mode)

25

80 Menu Mode
Output Funct. # (00 = Quit) 01

Output Function No.


(FA168CPS: 01-48 (FA148CP: 01-24) [] to continue; 00 to quit

Enter the output function number to be defined (or 00 to exit)

01 A E P Trig ?00 0 0 ZL=00

Summary Screen
[] to continue

01 Activated By: Zone List

Activated By
0 = delete 1 = zone list (go to A) 2 = zone type (go to B) 3 = zone number (go to C) [] to continue

This screen displays a summary of the current output programming (for this example, Zone List has been selected-this is the default screen). A = Output Action; E = Triggering event; P = Partition; Trig = Trigger type NOTE: A question mark in the summary screen indicates that the device number shown has not been mapped. Use *79 Menu mode to map the device. Select where the initiating event for this output definition is to occur as follows: If you enter 0, the following prompt appears: Delete? 0 = NO, 1 = YES Press 1 to delete this output definition. The system deletes the output function and any previous programming. (prompt appears if zone list was selected) Enter the desired zone list number associated with this output number. At the ENTER EVENT prompt, enter the zone list event that will activate this output NOTE: Do not use pager zone lists 09-12 in output definitions. Enter Event Alarm 1 0 = restore; 1 = alarm; 2 = fault; 3= trouble

Zone List
1 01-08 = zone list [] to continue

01 Zn List

Zone Type
See list at right for available zone types.

01 Enter Zn type Perimeter 03

NOTE: For alarm, fault, and trouble, an event on ANY zone in the list activates the output, but ALL zones in the list must be restored before the output is restored. Press [] to continue and skip to the Output Action prompt. (prompt appears if zone type was selected) Enter the desired zone type associated with this output number. At the PARTITION prompt, enter the partition in which this zone type will occur. CHOICES FOR ZONE TYPES:
00 = Not Used 01 = Ent/Exit #1 02 = Ent/Exit #2 03 = Perimeter 04 = Interior Follower 05 = Day/Night 06 = 24 Hr Silent 07 = 24 Hr Audible 08 = 24 Hr Aux 09 = Fire 10 = Interior w/Delay 12 = Monitor Zone 14 = Carbon Monoxide 16 = Fire w/verification 23 = No Alarm Response 24 = Silent Burglary 77 = Keyswitch Zone 81 = AAV Monitor Zone 90-91 = Configurable 58 = Duress 60 = AAV 61 = AVS/GSMV session begin 62 = AVS/GSMV session end 66 = Function Key 67 = Bell Fail 68 = Telco Line Cut 78 = Keyswitch Red LED 79 = Keyswitch Green LED

CHOICES FOR SYSTEM OPERATION:


20 = ArmingStay 21 = ArmingAway 22 = Disarming 31 = End of Exit Time 32 = Start of Entry Time 33 = Any Burglary Alarm 36 = **At Bell Timeout*** 38 = Chime 39 = Any Fire Alarm 40 = Bypassing 41 = **AC Power Failure 42 = **System Battery Low 43 = Comm. Failure 52 = Kissoff 54 = Fire Zone Reset

** Use 0 (Any) for Partition No. (P) entry. *** Or at Disarming, whichever occurs earlier. Use *57 Menu Mode to assign the function key (function 07). when used with an output function, the carbon monoxide zone type activates upon CO alarms only. Does not activate for trouble conditions. automatically set when appropriate AVS Quick Command performed.

Note: In normal operation mode: Code + # + 7 + NN Key Entry starts Device NN. Code + # + 8 + NN Key Entry stops Device NN. Enter the partition in which this zone type will occur. 01 Partition 0 = any partition; 1 = partition 1;

Any partition 0 2 = partition 2; 3 = common Press [ ] to continue and skip to the Output Action prompt.

26

C 01 Enter Zn No. 12

Press [] to continue.

Zone Number

01 Output Action Close for 2 sec 1

Output Action
0 = off 1 = Close for 2 seconds 2 = Stay Closed 3 = Pulse on & off (1 sec ON, 1 sec OFF) 4 = Change Device State 5 = Duration 1 (see data field *177) 6 = Duration 2 (see data field *177) Press [] to continue.

(prompt appears if zone number was selected) Enter the desired zone number associated with this output number. At the ENTER EVENT prompt, enter the zone event that will activate this output. 01 Enter Event 0 = restore; 1 = alarm/fault/trouble Restore 0 Press [] to continue to the Output Action prompt Enter the desired device action.

Enter Output No. R02 02

Output Number
01-16 = FA168CPS outputs 01-08 = FA148CP outputs 17-18 = on-board triggers Press [] to continue.

Enter the device output number (programmed in *79 Menu Mode) you want associated with this output.

02 A E P TRIG R02 1 1 3 ZL=00

Summary Screen

Press [] to continue.

A summary screen appears showing the programmed settings. Press [] to return to OUTPUT FUNCTION NUMBER prompt

81 ZONE LIST MENU MODE


(press *81 while in Programming mode) The Zone List Worksheet is on page Error! Bookmark not defined.. Zone lists let you group individual zones for use with certain system actions. Using this mode, simply select an appropriate zone list number, then add the desired zone numbers to be included in that list. The following table shows the available zone lists and their purposes: List No. Used for Notes 1, 2 general purpose (GP) Any list may include any or all of the system's zone numbers. 3 chime-by-zone (see field *26 to enable option) A zone list can be assigned to more than one output relay. 4 cross zones (see note at right) Zone List 4: When creating zone list 4 for cross zoning, 5 night stay zones include only zones assigned to zone types 3, 4, or 5. Do not 6 general purpose include zones that have delays (entry/exit zones, interior SIA-Compliant: dial delay disable w/delay) or 24-hour zones, as these zone types may produce 7 general purpose unpredictable operation and may not function as intended. SIA-Compliant: unlimited reports See field *85 for Cross Zone Timer option. 8 general purpose Zone List 6: SIA-Compliant: See field *50 for Dial Delay Disable 9 zones that activate Pager 1 option. 10 zones that activate Pager 2 Zone List 7: SIA-Compliant: See field *93 for Unlimited Reports 11 zones that activate Pager 3 (FA168CPS) option. 12 zones that activate Pager 4 (FA168CPS)

*81 Menu Mode


Zone List No. (00 = Quit)

Zone List Number


01 01-12 = zone list number [] to continue

Enter the Zone List Number to program (or 00 to quit). Press [] to advance. In the following displays, zone list 01 has been selected. Enter each zone number to add to the zone list, followed by pressing [] (example, 01, 02, 03). After all zones are entered, press 00 to continue. IMPORTANT: Do not include fire zones in zone lists that are used to STOP device actions. FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56. To delete the zone list, enter 1. All zones in the zone list will be deleted automatically and the system returns to the Zone List No. prompt. To save the zone list, enter 0.

01 Enter Zn Num. (00 = Quit) 00

Zone Number
01-64 = zone numbers followed by [] to accept each zone 00 to continue

01 Del Zn List? 0 = No 1 = Yes

Deleting Zone Lists


0 0 = dont delete list 1 = delete this zone list [] to continue

27

01 Delete Zone? 0 = No 1 = Yes

Deleting a Zone
0 0 = dont delete zones 1 = go to next prompt to delete zones [] to continue

To save the zone list, enter 0 and the system returns to the Zone List No. prompt. To delete a zone or zones in a zone list, enter 1 to continue.

01 Zn to Delete? (00 = Quit) 00

Delete the Zone


01-64 = zones to be deleted from list followed by [] to accept each zone 00 to continue

Enter each zone to be deleted from the list, followed by []. After all zones to be deleted are entered, enter 00 to return to the Zone List No. prompt so that another list can be programmed, if desired. FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.

82 ALPHA DESCRIPTOR MENU MODE


The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each description can be composed of a combination of up to 3 words selected from a vocabulary of words stored in memory (see Alpha Vocabulary List page). In addition, up to 10 installer-defined words can be added to those already in memory, plus 3 additional words can be assigned as partition descriptors. Thus, when an alarm or trouble occurs in a zone, an appropriate description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha display keypads, and are necessary if a 4286 Phone Module is used. NOTE: You can also enter zone descriptors when the zone is being defined in 56 Menu mode. 4286 NOTE: If using a 4286 Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type. The phone module will not provide annunciation of the other words. If a Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed, selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide annunciation of any other words.

82 Menu Mode
Program Alpha ? 0 = N o , 1 = Ye s 0 0

Program Alpha
0 = no (quit Alpha mode) 1 = yes [] to continue

The Program Alpha ? prompt will appear. Press 1 to continue.

Custom W ords ? 0 = N o , 1 = Ye s 0 0

Custom Words
0 = no 1 = yes

ZN 01

Summary Screen
[] to continue to edit mode

[#] = return to Program Alpha prompt (to quit)


ZN 01

Edit Mode Flashing Cursor


to edit = zone number then [], then zone number again 6 = save word and go to next word in a descriptor 8 = save descriptor and go to next zone [#] = return to Program Alpha prompt (to quit)

The Custom Words prompt will appear. Press 0 to program standard alpha descriptors from the fixed vocabulary. The system then automatically displays the descriptor for zone 1. Press 1 to define custom words (see Adding Custom Words). Note that this is a Summary mode, and that no entries can be made. Entries can be made only when the display contains a flashing cursor, which signifies Edit mode. To exit the Alpha Descriptor mode, press + 0 + 0 at the summary display. Descriptor screen for zone 1 appears. To program a descriptor (up to 3 words) for a zone, do the following: 1. Enter the desired zone number (existing descriptor, if any, is displayed) and press [], then enter the zone number again to start edit mode (flashing cursor appears). 2. a. Press [#] plus the 3-digit number from the Alpha Vocabulary List for the first word. b. Press [6] to accept the word and move the cursor for the next word in the descriptor. 3. Repeat steps 2a and 2b for the second and third words (if used). 4. When all words for that descriptor have been entered, press [8] to save the descriptor for that zone. The summary screen displays for that zone and the flashing cursor disappears. 5. Press [] at the summary screen and repeat steps 1-4 to assign a descriptor for the next zone. 6. When all descriptors have been entered, press [#]) at the last descriptor summary screen to return to the PROGRAM ALPHA? prompt. Enter 0 (no) at the prompt to exit this mode and return to Data Field mode.

28

EXAMPLE: (a) ZN 01

Descriptor Example
B ACK

(b) ZN 01

BACK

(c) ZN 01

BACK

D OOR
(d) ZN 01

EXAMPLE: BACK DOOR a. From the list, BACK = 013, so, after entering the zone number to be edited (step 1), enter #013. If you accidentally enter the wrong word, simply press [#] plus the correct 3-digit number for the word you want. b. Press [6] to accept the selected word and continue to the next word. (if this is the only word you are using for the descriptor press [8] to save it). c. Enter the 3-digit number for the next word, DOOR, whose number is 057. Enter # 0 5 7. d. Because this is the last word in the example descriptor, press [8] to save it. (If there was a third word in the descriptor, press [6] to accept the selected word and continue to the third word.) The summary screen displays with the selected descriptor.

BACK

DOOR
ZN 01 BACK

Summary Screen
[] = to enter another zone

DOOR

number [#] = return to Program Alpha prompt (to quit)

The flashing cursor disappears, indicating that the word(s) are saved for that zone, as shown in the summary display at the left. To enter a descriptor for the next zone, press [] plus the desired zone number. The summary display appears. Repeat the previous steps to enter the descriptor for the zone.

Adding Custom Words (will not be annunciated by 4286 Phone Module)


You can add up to 10 installer-defined words to the built-in vocabulary, which can then be used when programming zone descriptors. Each of the 10 words can actually consist of a word string of one or more words, but no more than ten characters can be used for each word or word string. When adding custom words, the keypad keys perform the following functions: [4] Moves cursor one space to the left. [6] Moves cursor one space to the right. [8] Saves the new word in the system's memory. Select Custom Word mode (enter 1) when the prompt CUSTOM WORD ? is displayed. Enter the number (0110) of the custom word or word string to be created, corresponding to index numbers 245 - 254 respectively (for example, if you are creating the first custom word or word-string, enter 01, for the second, enter 02, etc.). A cursor will now appear at the beginning of the second line. or 11, 12, 13 for partition 1, partition 2 and common lobby descriptors respectively. See Assigning Partition Descriptors paragraph below. NOTE: Custom words 8, 9, and 10 are reminder words that are programmed using Scheduling Mode. Refer to the Character List of letters, numbers, and symbols on a following page. Press [#], followed by the two-digit entry for the first letter you would like to display (e.g., # 65 for A). The cursor moves to the right, in position for the next character. To delete a character, simply enter the SPACE character (#32) at the unwanted characters location.. Repeat Step 3 to create the desired word(s). Note that the 4 key can be used to move the cursor to the left, if necessary. Remember, no word or word-string can exceed 10 characters (except custom message/partition descriptor word numbers 11, 12, and 13, which can be a maximum of 16 characters). When the word is complete, press the [8] key to save the custom word(s) and return to the CUSTOM WORD ? display. Repeat Steps 25 for other custom words to be entered. To change a custom word, just overwrite it. When all words have been programmed, press [0] to return to the Descriptor entry. The custom word(s) will be automatically added to the builtin vocabulary.

1. 2.

3.

4. 5.

Assigning Partition/Custom Message Descriptors FA148CP: You can create a custom message display that appears on alpha keypads instead of System Ready. To assign a custom message, use word number 11 as described below. FA168CPS: You can assign a partition descriptor (up to 16 characters) for each partition plus the common lobby. The system displays the appropriate partitions word instead of DISARMED READY TO ARM. Use the same procedure as for adding custom words (described above), but use these word numbers in step 2: 11 = partition 1 ___________________________________________ 12 = partition 2 ___________________________________________ (FA168CPS only) 13 = common lobby ________________________________________ (FA168CPS only) Once a custom word is entered in any of these word locations (11-13), the system displays the appropriate partitions word instead of the default DISARMED READY TO ARM message.

29

ALPHA VOCABULARY LIST (For Entering Zone Descriptors)


000 001 002 004 005 006 007 009 010

012 013 014 016 017 018 019 020 021 022 023 025 026
028 029 030 031 033 034 035 036 037 038 040 046 047 048 049 050 051 052 053 054 055

(Word Space) A AIR ALARM ALLEY AMBUSH AREA APARTMENT ATTIC AUDIO B BABY BACK BAR BASEMENT BATHROOM BED BEDROOM BELL BLOWER BOILER BOTTOM BREAK BUILDING C CABINET CALL CAMERA CAR CASH CCTV CEILING CELLAR CENTRAL CIRCUIT CLOSED COMPUTER CONTACT D DAUGHTERS DELAYED DEN DESK DETECTOR DINING DISCRIMINATOR DISPLAY

057 059 060 061 062 064


065 066 067 068 069 071 072 073 075 076 077 079 080 081 082 083 084 085

089 090 091 092 093 094 095 096 098 099 100 101 102 103
104

105

DOOR DOWN DOWNSTAIRS DRAWER DRIVEWAY DUCT E EAST ELECTRIC EMERGENCY ENTRY EQUIPMENT EXIT EXTERIOR F FACTORY FAMILY FATHERS FENCE FIRE FLOOR FLOW FOIL FOYER FREEZER FRONT G GARAGE GAS GATE GLASS GUEST GUN H HALL HEAT HOLDUP HOUSE INFRARED INSIDE INTERIOR INTRUSION J JEWELRY K KITCHEN

106 107 108 109 110 111 113 114 115 116 117 118
119 121 122 123 125 126 128 129 130 131 132 134 135

136 138 139 140 142


143 144 145 146 147 148 150 151 152 153

L LAUNDRY LEFT LEVEL LIBRARY LIGHT LINE LIVING LOADING LOCK LOOP LOW LOWER M MACHINE MAIDS MAIN MASTER MEDICAL MEDICINE MONEY MONITOR MOTHERS MOTION MOTOR N NORTH NURSERY O OFFICE OPEN OPENING OUTSIDE OVERHEAD P PAINTING PANIC PASSIVE PATIO PERIMETER PHONE POINT POLICE POOL POWER

155 156 157 159 160 161 162 163 164 165 166 167 168 169 170 171 173 174 175 176 178 179 180 182 184 185 186 190 191 192 193

194 196 197 199 200 201 202 205 206 207 208

R RADIO REAR RECREATION REFRIGERATION RF RIGHT ROOM ROOF S SAFE SCREEN SENSOR SERVICE SHED SHOCK SHOP SHORT SIDE SKYLIGHT SLIDING SMOKE SONS SOUTH SPRINKLER STATION STORE STORAGE STORY SUPERVISED SUPERVISION SWIMMING SWITCH T TAMPER TELCO TELEPHONE TEMPERATURE THERMOSTAT TOOL TRANSMITTER U UP UPPER UPSTAIRS UTILITY

209 210 212 213 214 216 217 219 220 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254

V VALVE VAULT VOLTAGE W WALL WAREHOUSE WEST WINDOW WING WIRELESS X XMITTER Y YARD Z ZONE (No.) ZONE 0 1 1ST 2 2ND 3 3RD 4 4TH 5 5TH 6 6TH 7 7TH 8 8TH 9 9TH Custom Custom Custom Custom Custom Custom Custom Custom Custom Custom Word #1 Word #2 Word #3 Word #4 Word #5 Word #6 Word #7 Word #8 Word #9 Word #10

Note:

Bulleted () words in boldface type are those that are also available for use by the 4286 Phone Module. If using a Phone module, and words other than these are selected for Alpha descriptors, the module will not provide annunciation of those words. Italicized words followed by an asterisk indicate those words supported by the 6160V/6150V Voice Keypads

CHARACTER (ASCII) CHART (For Adding Custom Words)


32 (space) 33 ! 34 " 35 # 36 $ 37 % 38 & 39 ' 40 ( 41 42 43 44 45 46 47 48 49 ) * + , . / 0 1 50 51 52 53 54 55 56 57 58 2 3 4 5 6 7 8 9 : 59 60 61 62 63 64 65 66 67 ; < = > ? @ A B C 68 69 70 71 72 73 74 75 76 D E F G H I J K L 77 78 79 80 81 82 83 84 85 M N O P Q R S T U 86 87 88 89 90 V W X Y Z

30

SETTING SCHEDULES
(Installer Code + [#] + [6] [4])

The system provides schedules, which can be used to automatically control 11 types of system events at pre-defined times. Some events are reserved for the installer only. FA168CPS: Provides up to 32 schedules: 16 schedules for use by the end-user, 16 for use by the installer. FA148CP: Provides up to 8 schedules: 4 schedules for use by the end user, 4 for use by the installer. NOTES: The master code can only access schedules 01-16 (FA148CP = 01-04) and events 00-07. System clock must be set before schedules can take effect. Programmed schedules do not take effect until the next scheduled start time. (e.g., if programming a schedule time window for 8AM to 5PM, the schedule does not take effect until 8AM after the schedule has been programmed.) Schedule Mode
ENTER SCHED NO. 00=QUIT 00

Schedule Number
FA168CPS 01-16 = end-user schedules 17-32 = installer-only FA148CP 01-04 = end-user schedules 05-08- = installer-only [] to continue

Enter the desired schedule number. To Quit, enter 00.

ENTER EVENT

Enter Event
00 = clear event 01 = Relay On/Off 02 = User Access 03 = Latch Key Report to Pager 04 = Forced Stay Arming 05 = Forced Away Arming 06 = Auto Disarm 07 = Display Reminder 10 = Display custom words 11 = Periodic Test Report Press [] to continue.

Enter the desired event number for event you want to occur at a specified time. Events 10-11 are reserved for the installer only. Latch key report (option 03) is sent to all pagers in the users partition and is active only when the system is armed (message sent is 777-7777). User must be enabled for paging (see User Attributes in System Operation section). Forced bypass is automatically enabled regardless of setting in field *23. If selected, system displays custom words 8, 9, and 10 at defined time. Can be used as installers reminder message to the end user. See key commands in Test Report Code data field *64 section to quickly set periodic test reporting intervals.
NOTE: Events 07 and 10 cause the keypad to beep every 30 seconds when messages are displayed. Stop the beeps by pressing any key.

DEVICE NUMBER XX

Device Number
FA168CPS: 01-18 = device number FA148CP: 01-08, 17, 18 Press [] to continue.

(For event 01-relay on/off) Enter the physical device number as programmed in 79 Menu Mode, then press [*] to continue to the Start prompt. Device numbers 17 and 18 designate built-in triggers 1 and 2 respectively. (For event 02-user access)

GROUP NUMBER X

Group Number
1-8 = group number Press [] to continue to the Start prompt.

PARTITION X

Partition
0 = all partitions 1 = partition 1 2 = partition 2 3 = common Press [*] to continue to the Start prompt.

(FA168CPS only; for events 03-07, 10)

START

SMTW TFS HH MMAM 0 0 1 0 0 0 0

Start Time
01-12 = hour 00-59 = minute 0 = AM; 1 = PM Days = place 1 under days Press [] to continue.

Enter the events start time and days of the week to occur. To select days, position the cursor under the desired days using the [] key to move forward, then press 1 to select the day.

STOP

SMTW TFS HH MMAM 0 0 1 0 0 0 0

Stop Time
01-12 = hour 00-59 = minute 0 = AM; 1 = PM Days = place 1 under days Press [] to continue.

(For events 01-relay on/off; 02-user access; 03-latch key report) Enter the events stop time and days of the week to occur. To select days, position the cursor under the desired days using the [] key to move forward, then press 1 to select the day.

31

REPEAT OPTION
0-4 X

Repeat Option
0 = do not repeat 1 = repeat weekly 2 = repeat biweekly (every other week) 3 = repeat every third week 4 = repeat every fourth week Press [] to continue.

Enter the desired repeat option for this schedule. e.g., To make a schedule that happens everyday you would select all days with a repeat count of 1. To make a schedule that runs for one week then stops, select everyday with a repeat count of 0.

RANDOMIZE
0=NO 1=YES X

Randomize
0 = no 1 = yes Press [] to continue and return to ENTER SCHED NO. prompt to program the next schedule.

(For events 01 and 11) If selected, the scheduled start and stop times will vary within 60 minutes of the hour time. For example, if a schedule is set to start at 6:15pm, it will do so the first time 6:15pm arrives, but on subsequent days it will start anytime between 6:00 and 6:59 p.m. NOTE: Do not use the random option if the start and stop times are within the same hour setting, otherwise unpredictable results may occur (e.g., the randomized stop time may occur before the start time).

AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS


Applies to an AVS system using an ECP connection to the control. 1. Install the AVS module according to its instructions. 2. Use one of the controls AVS Quick Program commands as follows (see Quick Program Command Results below for results of each command): installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker 3. Use data field 55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for AAV communication. 4. To undo the Quick Command programming, use the following commands: installer code + [#] + 0 + 5: remove all options that were set if [#] + 03 quick command was performed installer code + [#] + 0 + 6: remove all options that were set if [#] + 04 quick command was performed

Quick Program Command Results


When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer available for other control panel purposes.
Pre-Programmed Output Function No. (80 mode) #03 Command FA148CP FA168CPS 22 (zone type 60, relay 07) 46 (zone type 60, relay 15) 23 (zone type 61, relay 08) 47 (zone type 61, relay 16) 24 (zone type 62, relay 08) 48 (zone type 62, relay 16) #04 Command FA148CP FA168CPS Same as #03 plus: Same as #03 plus: 17 (zone type 14, relay 05) 41 (zone type 14, relay 13) 18 (zone type 22, relay 05) 42 (zone type 22, relay 13) 19 (zone type 39, relay 06) 43 (zone type 39, relay 14) 20 (zone type 33, relay 06) 44 (zone type 33, relay 14) 21 (zone type 22, relay 06) 45 (zone type 22, relay 14 Same as #03 plus: Same as #03 plus: 05 (addr 08, relay pos 4) 13 (addr 11, relay pos 4) 06 (addr 08, relay pos 3) 14 (addr 11, relay pos 3) Same as #03 command Same as #03 command Same as #03 command AAV enabled Same as #03 command AAV enabled

Output Relay No. (79 mode) Protection Zone (56/58 mode) Device Address Data Field 91

07 (addr 08, relay pos 2) 08 (addr 08, relay pos 1) 4229 zn 24 (zt 81, addr 08) address 08 (AVS module) AAV enabled

15 (addr 11, relay pos 2) 16 (addr 11, relay pos 1) 4229 zn 48 (zt 81, addr 11) address 11 (AVS module) AAV enabled

SETTING THE REAL-TIME CLOCK


IMPORTANT: The Real-Time Clock must be set before the end of the installation. NOTE: All partitions must be disarmed before the date/time can be set. 1. Master Code + [#] + [6] [3] 2. Press [] when the time/date is displayed. A cursor appears under the first digit of the hour. To move cursor ahead, press []. To go back, press [#]. Enter the 2-digit hour setting. Enter the 2-digit minute setting. Press [1] for PM or [2] for AM. Enter the last two digits of the current year. Enter the 2-digit month setting. Enter the 2-digit day setting. 3. To exit, press [] when cursor is at the last digit, or wait 30 seconds.

32

29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming)


This mode is for programming an IP, GSM, or IP/GSM Communicator Module using an alpha keypad. Alternatively, these options can be programmed via the AlarmNet Direct website. After programming is complete, the module must be registered with AlarmNet before reporting via the communication device can occur. Refer to the devices instructions for registration procedures. NOTE: The module must be set to device address 3.
IMPORTANT: The use of an IP/GSM Communicator Module requires an AlarmNetI account. Please obtain the account information from the central station prior to programming this module.

Using an Alpha Keypad as a 7720P Programming Tool When programming with 29 menu mode, the alpha keypad mimics the functions of the 7720P Programming Tool. See figure to right and table below for 7720P key functions. Each key has two possible functions: a normal function and a SHIFT function. Normal functions: The numeric values labeled directly on the keys and the left-hand functions shown in diagram on the ABC keys. To perform a normal key function, simply press the desired key. SHIFT functions: Those functions shown in diagram above the numerical keys and the right-hand functions shown on the ABC keys. To perform a SHIFT key function, press SHIFT key (D key), then press the desired function key (shift function is indicated by the lit READY LED).

ARMED

READY

SHIFT FUNCTION WHEN LIT


R

(A) (B) (C) (D)

BS/ESC

1 4

..

2 )9);
E

3 56);
F

D /
):

5 6-56
T

6 *;2)55
X

S N/Y

71 56) 6
SPACE
4-),;

8+ 0

,-

9 +01 #

ENTER

SHIFT

FA 5 6 0
FA560KP-005-V0

7720P Emulation Template for Alpha Keypads

29 IP/GSM Program Mode

Press 29 while in Data Field Programming mode. The following prompts appear. If using a communication device, enter 1 at this prompt and Enable IP/GSM? ENABLE IP/GSM? 0 = no, not using IP or GSM; enter 1-Prog at the next prompt to program and register the 0=No, 1=Yes device. Use the communication devices Installation Guide for 1 = yes using IP and/or details of the devices programming prompts and instructions for GSM module registration. [] to continue
[Default = 0 (no IP and/or GSM)] 1=PROG 2=DIAG 0=QUIT

Programming / Diagnostics Select


1= Prog (program the IP/GSM options) 2 = Diag (enter diagnostic mode) 0 = Quit; returns to data field programming mode

Select whether you want to program the communication device or enter the devices diagnostic mode. Diagnostic Mode Note: Diagnostic mode option available only for communicators with firmware version 2.4.16 or higher.

Normal and SHIFT key Functions While in 29 Menu Mode Key Normal Key Function SHIFT Key Function (A) = BS/ESC [BS]: Press to delete entry [ESC]: Press to quit Program Mode Also, can reset EEPROM defaults (B) = / []: Scroll down programming []: Scroll up programming (C) = N/Y [N]: Press for "NO" answer [Y]: Press SHIFT-Y for "YES" answer (D) = SHIFT Press before pressing a SHIFT key function. Will light READY LED. LED goes out once a key is pressed. Press again for each SHIFT function desired. 1/A [1]: For entering the number 1 [A]: Used for entering C.S. ID number 2/B [2]: For entering the number 2 [B]: Used for entering C.S. ID number 3/C [3]: For entering the number 3 [C]: Used for entering C.S. ID number 4/D [4]: For entering the number 4 [D]: Used for entering C.S. ID number 5/E [5]: For entering the number 5 [E]: Used for entering C.S. ID number 6/F [6]: For entering the number 6 [F]: Used for entering C.S. ID number 7/S [7]: For entering the number 7 [S]: Press to display diagnostic status 8/T [8]: For entering the number 8 [T]: Press to send TEST messages 9/X [9]: For entering the number 9 [X]: Press to reset the IP/GSM [SPACE]: Not used [] / SPACE []: Used to select programming options 0 [0]: For entering the number 0 [#] / ENTER [#] / ENTER: Press to accept entries No SHIFT function
Active only when the "REVIEW?" prompt is displayed

33

ZONE TYPE DEFINITIONS


Zone types define the way in which the system responds to faults in each zone.
Type 00 Zone Not Used Program a zone with this zone type if the zone is not used. Type 01 Entry/Exit Burglary #1 Assign to zones that are used for primary entry and exit. Provides entry delay when zone is faulted if control is armed in the Away, Stay, or Night-Stay modes. No entry delay provided when the panel is armed in the Instant/Maximum mode. Entry delay #1 is programmable for each partition (field *35). Exit delay begins whenever the control is armed, regardless of the arming mode selected, and is programmable (field 34). Type 02 Entry/Exit Burglary #2 Assign to zones that are used for entry and exit and require more time than the primary entry/exit point. Provides a secondary entry delay, similar to entry delay #1. Entry delay #2 is programmable for each partition (field *36). Exit delay is same as described for Type 01. Type 03 Perimeter Burglary Assign to all sensors or contacts on exterior doors and windows. Provides an instant alarm if the zone is faulted when the panel is armed in the Away, Stay, Night-Stay, Instant or Maximum modes. Type 04 Interior Follower Assign to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry (to and from the keypad). Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit zone is faulted first. Otherwise this zone type gives an instant alarm. Active when the panel is armed in the Away mode. Bypassed automatically when the panel is armed in the Stay or Instant modes; if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list) are not bypassed when system armed in Night-Stay mode. Type 05 Trouble by Day/Alarm by Night Assign to a zone that contains a foil-protected door or window (such as in a store), or to a zone covering a sensitive area such as a stock room, drug supply room, etc. Can also be used on a sensor or contact in an area where immediate notification of an entry is desired. Provides an instant alarm if faulted when armed in the Away, Stay, Night-Stay, Instant or Maximum (night) modes. During the disarmed state (day), the system will provide a latched trouble sounding from the keypad (and a central station report, if desired). Type 06 24-hr Silent Alarm Usually assigned to a zone containing an emergency button. Sends a report to the central station but provides no keypad display or sounding. Type 07 24-hour Audible Alarm Assign to a zone that has an emergency button. Sends a report to the central station, and provides an alarm sound at the keypad, and an audible external alarm. Type 08 24-hour Auxiliary Alarm Assign to a zone containing an emergency button, or to a zone containing monitoring devices such as water or temperature sensors. Sends a report to the central station and provides an alarm sound at the keypad. (No bell output.) Type 09 Supervised Fire Provides a fire alarm on short circuit and a trouble condition on open circuit. A fire alarm produces a pulsing bell output. This zone type is always active and cannot be bypassed. Type 10 Interior w/Delay Provides entry delay (using the programmed entry time), if tripped when the panel is armed in the Away mode. Entry Delay 1 begins whenever sensors in this zone are violated, regardless of whether or not an entry/exit delay zone was tripped first. Bypassed when the panel is armed in the Stay or Instant modes; if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list) are not bypassed when system armed in Night-Stay mode. Type 12 Monitor Zone Works as a dynamic monitor of a zone fault/trouble (not alarm). In the case of a short/open, the message, "*ALARM*-24 Hr. Non-Burg. -#XXX " (where XXX is the zone number) will be sent to the Central Station. The system keypad will display a check message indicating the appropriate zone (but keypad beeping does not occur). Upon restoral of the zone, the message, "*RESTORE*-24 Hr. Non-Burg. -#XXX " will be sent to the Central Station. The check message will automatically disappear from the keypad dynamically, when the zone restores; a user code + off sequence is not needed to reset the zone. Faults of this zone type are independent of the system, and can exist at the time of arming without interference. Since this is a trouble zone type, do not use this zone type with relays set to activate upon alarm. Type 14 24 Hour Carbon Monoxide Monitor Assigned to any zone with a carbon monoxide detector. A carbon monoxide alarm produces keypad and detector sounding (does not affect bell output). Always active and cannot be bypassed. Type 16 Fire w/Verification Provides a fire alarm when zone is shorted, but only after alarm verified. Verifies alarm by resetting smoke detectors after short is detected (removes power 7 seconds for zone 1, 3 seconds for trigger output). Another short circuit within 90 seconds triggers fire alarm. Provides a trouble response when zone is open. Type 20 Arm-Stay (BR only) Arms the system in Stay mode when the zone is activated. Pushbutton units send the user number to the central station when arming or disarming. User number for button must be assigned. Type 21 Arm-Away (BR only) Arms the system in Away mode when the zone is activated. Pushbutton units send the user number to the central station when arming or disarming. User number for button must be assigned. Type 22 Disarm (BR only) Disarms the system when the zone is activated. User number for button must be assigned. Type 23 * No Alarm Response Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., lobby door access). Type 24 Silent Burglary Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are NOT desired. Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is faulted when the system is armed in the Away, Stay, Instant, or Maximum modes. A report is sent to the central station. Type 77 Keyswitch Assign to zone wired to a keyswitch. Do not use input type BR devices with this zone type. Type 81 AAV Monitor Zone Assign to zone connected to AAV module. Monitors 2-way voice sessions as follows: - When the zone is faulted, all alarm sounding and dialer reporting stops, except for fire alarms, which immediately terminate the voice session and cause a fire report to be sent. - When the zone is restored (session ended), sounding resumes (if bell timeout has not expired) and reports that were stopped are sent. Types 90-93 Configurable Allows for various custom responses. Options include response to entry/exit delays, response opens/shorts, types of alarm/trouble sounding, dial delay, and unique Contact ID report codes. Types 92 and 93 can only be programmed via downloader. UL installations: Zone Types 90 -93 may not be used as fire or burglar alarm zones on fire or UL burglar alarm installations.

* The system can still be armed when these zone types are in a
faulted condition.

34

UL NOTICES
1. Entry Delay No. 1 and No. 2 (fields 35, 36) cannot be greater than 30 seconds for UL Residential Burglar Alarm installations, and entry delay plus dial delay should not exceed 1 minute. For UL Commercial Burglar Alarm installations, total entry delay may not exceed 45 seconds. 2. For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. 3. The maximum number of reports per armed period (field 93) must be set to 0 (unlimited) for UL installations. 4. Periodic testing (see scheduling mode) must be at least every 24 hours. 5. Alarm Sounder plus Auxiliary Power currents must not exceed 600mA total for UL installations (Aux power 500mA max.). 6. All partitions must be owned and managed by the same person(s). 7. All partitions must be part of one building at one street address. 8. If used, the audible alarm device(s) must be placed where it/they can be heard by all partitions. 9. For UL commercial burglar alarm installations the control unit must be protected from unauthorized access. The tamper switch installed to protect the control unit enclosure door is suitable for this purpose. 10. Remote downloading without an alarm company technician on-site (unattended downloading) is not permissible for UL installations. 11. Auto-disarming is not a UL Listed feature. 12. As SIA limits for delay of alarm reporting and sounding can exceed UL limits for commercial and residential applications, the following UL requirements per UL681 are provided: The maximum time that a control unit shall be programmed to delay the transmission of a signal to a remote monitoring location, or to delay the energizing of a local alarm sounding device to permit the alarm system user to enter and disarm the system, or to arm the system and exit shall not exceed: a) 60 seconds for a system with standard line security or encrypted line security, b) 120 seconds for a system without standard line security or encrypted line security, or c) 120 seconds for a system that does not transmit an alarm signal to a remote monitoring location. 13. This control is not intended for bank safe and vault applications.

SIA QUICK REFERENCE GUIDE


1. 2. 3. 4. 5. 6. 7. 8. 9 10. 11. 12. 13. 14. 15. 31 Single Alarm Sounding per Zone: If 0 selected, alarm sounding per zone will be the same as the number of reports in armed period set in field 93 (1 if one report, 2 if 2 reports, unlimited for zones in zone list 7). 34 Exit Delay: Minimum exit delay is 45 seconds. 35/*36 Entry Delay 1 and 2: Minimum entry delay is 30 seconds. 37 Audible Exit Warning: Feature always enabled; field does not exist. 39 Power Up in Previous State: Must be 1, power up in previous state. 40 PABX Access Code or Call Waiting Disable: If call waiting is used, call waiting disable option in field *91 must be set. 50 Burglary Dial Delay: Delay must be minimum of 30 seconds. 59 Exit Error Alarm Report Code: Always enabled. 68 Cancel Report Code: Default is code enabled. 69 Recent Closing Report Code: Always enabled. 91 Option Selection: Exit Delay option should be enabled. If call waiting is used, Call Waiting Disable must be set to 1 (enabled). 93 No. reports in Armed Period: Must be set for 1 or 2 report pairs. Cross zone timer programming is set in field 85; cross zone pairs are assigned in zone list 4 using 81 Zone List mode. Duress code is assigned by using the add a user code procedure found in the User Guide. Enable Duress code reporting by programming zone 92 using 56 Zone Programming mode. Fire alarm verification is a built-in system feature when a zone is programmed for zone type 16.

35

WORKSHEET FOR 56 ZONE PROGRAMMING


(FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets]
Zone Zn Type Part. Report Hardwire Type Rsp. Time Location

1 2 3 4 5 6 7 8
Zone

[09] [01] [03] [03] [03] [03] [03] [03]


Zn Type

[1] [1] [1] [1] [1] [1] [1] [1]


Part. Report

[EOL] [EOL] [EOL] [EOL] [EOL] [EOL] [EOL] [EOL]


Input Type Loop

[1] [1] [1] [1] [1] [1] [1] [1]


Serial No. Location

NOTES:
Zone Type: see chart in 56 Zone Programming Menu mode section. Report Code: enabled if any digit entered as 1st digit; Hardwire Type (zns 2-8): 0 = EOL 3 = ZD 1 = NC 4 = DB 2 = NO Input Type: 2 = AW (zones 9-48) 3 = RF (zones 9-48) 4 = UR (zones 9-48) 5 = BR (zones 49-64) NOTE: Zones 9-16 not available if zone doubling enabled. Response Time: 0 = 10msec 1 = 350msec 2 = 700msec 3 = 1.2 sec

Reserved Zones 91 = addressable device


report enable/disable default zone type = [05].

92 = Duress report
enable/disable

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 95 96 99

[00] [00] [06]

[1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] N/A** N/A** N/A**

[BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] [BR] N/A N/A N/A

N/A N/A N/A N/A N/A N/A

keypad [1] / [] keypad [3] / [#] keypad [] / [#]

** Emergency key zones 95, 96, and 99 report the partition of the keypad used to activate the emergency zones.

36

WORKSHEET FOR 57 FUNCTION KEY PROGRAMMING


Option 01 02 03 04 05 06 07 08 09 10 11 12 00 Function A B C D Comments Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Macro Key 2 Macro Key 3 Macro Key 4 zone 95 zone 99 zone 96 paging Emergency Keys: n/a Personal Emergency n/a Silent Alarm n/a Audible Alarm n/a Fire Emergency Keys: A = paired keys [1] / [] (zone 95); B = paired keys [] / [#] (zone 99); C = paired keys [3] / [#] (zone 96)

WORKSHEET FOR 79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING


Applicable only if Relays and/or Powerline Carrier Devices are to be used. Must program before using *80.
OUTPUT TYPE Relay X10 Output Module Pos Unit Description No. Addr. (1-4) No. 01 02 03 04 05 06 07 08 OUTPUT TYPE (09-16 apply to FA168CPS only) Relay X10 Output Module Pos Unit Description No. Addr. (1-4) No. 09 10 11 12 13 14 15 16 On-Board Trigger 1 norm output = 17 On-Board Trigger 2 norm output = 18

WORKSHEET FOR 81 ZONE LIST PROGRAMMING


Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. NOTE: Record desired zone numbers below, noting that a list may include any or all of system's zone numbers. List No. 01 02 03 04 05 06 07 08 09 10 11 12 Used For
General Purpose (GP) General Purpose Chime-by-Zone or GP Cross Zones Night-Stay Zones or GP Dial Delay Disable or GP Unlimited Reports or GP General Purpose Zones activating pager 1 Zones activating pager 2 Zones activating pager 3 Zones activating pager 4 (FA168CPS) (FA168CPS)
SIA-Compliant Controls: see field *50 for Dial Delay Disable option SIA-Compliant Controls: see field *93 for Unlimited Reports option (see field *26 for Chime-by-Zone option) (see field *85 for Cross Zone Timer option)

Contains These Zones

37

WORKSHEET FOR 80 OUTPUT FUNCTION PROGRAMMING


Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. 2. For Powerline Carrier devices (plcd), field 27 must be programmed with a House Code. 3. Tampers of expansion units cannot be used to operate devices.
Output Function Number (FA168CPS: 1-48) (FA148CP: 1-24) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are: 00 = Not Used 05 = Trouble Day/Alarm Night 10 = Interior w/Delay 24 = Silent Burglary 01 = Entry/Exit#1 06 = 24 Hr Silent 12 = Monitor Zone 77 = Keyswitch 02 = Entry/Exit#2 07 = 24 Hr Audible 14 = Carbon Monoxide 81 = AAV Monitor Zone 03 = Perimeter 08 = 24 Hr Aux 16 = Fire w/Verification 90-91 = Configurable 04 = Interior Follower 09 = Fire 23 = No Alarm Response Choices for System Operation are: Note: In normal operation mode: 20 = ArmingStay 38 = Chime 58 = Duress Code + # + 7 + NN Key Entry starts Device 21 = ArmingAway 39 = Any Fire Alarm 60 = AAV Trigger Code + # + 8 + NN Key Entry stops Device 22 = Disarming (Code + OFF) 40 = Bypassing 61 = AVS/GSMV session begin 31 = End of Exit Time 41 = **AC Power Failure 62 = AVS/GSMV session end ** Use 0 (any) for Partition No. (P) entry. 32 = Start of Entry Time 42 = **System Battery Low 66 = Function key *** Or at Disarming, whichever occurs earlier. 33 = Any Burglary Alarm 43 = Communication Failure 67 = Bell Failure Use *57 Menu mode to assign the function key. 36 = **At Bell Timeout*** 52 = Kissoff 68 = TELCO Line Fault Duration is set in program field *177. 54 = Fire Zone Reset 78 = Keyswitch red LED Device action not used for these choices. 79 = Keyswitch green LED automatically set when appropriate AVS Quick Command performed. Activation Type and Detail Activated by Zone List Zone Type Zone No. (ZN) 0=delete (ZL) (ZT) 1=zn list 1-8 = list (see table 00=none FA168CPS: 2=zn type below) 01-64 3=zn no. Event (for zone list/activated by) Output Device Action Number Type 0 = off By Zone List By Zone No. 1 = close 2 secs (if using ZT trig) 0 = restore 2 = stay closed FA168CPS: R = relay 0 = restore 0 = any 1-18 T = trigger 1 = alarm 1 = alrm/flt/trbl 3 = pulse 1 = partition 1 2 = fault X = X10 4 = toggle FA148CP: 2 = partition 2 3 = trouble 5 = duration 1 FA148CP: 01-06, 09-34, 3 = common 6 = duration 2 1-8, 17, 18 49-56 Partition Number (P)

38

WORKSHEET FOR SCHEDULES


(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and events 00-07 for both controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules )

No.

Event
(see list below)

Device No.
for 01 events: enter 01-18

Group No.
for 02 events: enter 1-8

Partition
for 04-06 events: enter 1, 2, or 3

Start Time/ Days

Stop Time/ Days

Repeat
(1-4)

Random
(yes/no)

Master/Installer Installer Only 00 = clear event 03 = latch key report 06 = auto disarm 10 = display custom words 8-10 01 = device on/off 04 = forced STAY arm 07 = display reminder 11 = periodic test report 02 = user access 05 = forced AWAY arm Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Events:

TABLE OF DEVICE ADDRESSES


This Device Uses Address RF Receiver 00 AUI 1 01 AUI 2 02 AUI 3 05 AUI 4 06 Communication Device (LRR) 03 4286 Voice Module 04 Zone Expanders (4219/4229): module 1 (for zones 09 - 16) 07 module 2 (for zones 17 - 24) 08 module 3 (for zones 25 - 32) 09 (FA168CPS) module 4 (for zones 33 - 40) 10 (FA168CPS) module 5 (for zones 41 - 48) 11 (FA168CPS) Relay Modules (4204): module 1 12 module 2 13 module 3 14 (FA168CPS) module 4 15 (FA168CPS) Keypads: keypad 1 16 keypad 2 17 keypad 3 18 keypad 4 19 keypad 5 20 keypad 6 21 keypad 7 22 keypad 8 23 5800TM Module 28 Reports as 100 Enabled By *56 zone programming: input device type entry automatic if AUI enable field *189 enabled for AUI 1 automatic if AUI enable field *189 enabled for AUI 2 automatic if AUI enable field *189 enabled for AUI 3 (FA168CPS) automatic if AUI enable field *189 enabled for AUI 4 (FA168CPS) automatic if communication device enabled in 29 Menu mode automatic if phone module access code field *28 enabled *56 zone programming: input device type entry, then: automatic if zone no. 9-16 entered as AW type or relay assigned automatic if zone no. 17-24 entered as AW type or relay assigned automatic if zone no. 25-32 entered as AW type or relay assigned automatic if zone no. 33-40 entered as AW type or relay assigned automatic if zone no. 41-48 entered as AW type or relay assigned *79 output device programming: device address prompt: entered at device address prompt entered at device address prompt entered at device address prompt entered at device address prompt data field programming as listed below: always enabled, all sounds enabled. data field *190 Addressable devices are identified by 1 plus data field *191 the device address when reporting. Enter report data field *192 code for zone 91 to enable addressable device data field *193 reporting (default = reports enabled). See field *19 data field *194 for addressable device (ECP) 3-digit/2-digit data field *195 identification keypad display options. data field *196 automatic

103 104 107 108 109 110 111 112 113 114 115 n/a n/a n/a n/a n/a n/a n/a n/a n/a

39

5800 SERIES TRANSMITTER INPUT LOOP IDENTIFICATION


All of the transmitters illustrated have one or more unique factory assigned input (loop) ID numbers. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). For information on any transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc. UL NOTE: The following transmitters are not intended for use in UL installations: 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850. The 5827BD and 5800TM can be used in UL Listed Residential Burglar installations.
LOOP 3 LOOP 4 YOU MUST ENROLL THIS BUTTON LOOP 1 LOOP 2 LOOP 1 LOOP 1

LOOP 1 LOOP 1

LOOP 1

5800CO
ENROLL AS "RF"

5800Micra
ENROLL AS "RF"

5800SS1
E N RO L L A S " R F "

5 8 0 0 WAV E
SET HOUSE ID E N RO L L A S " R F "

5801
E N RO L L A S "UR OR"RF"

5802 MN
ENROLL AS "UR" OR "RF"

LOOP 3 LOOP 4 YOU MUST ENROLL THIS BUTTON


ON OFF

LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON


SERIAL #1 LOOP 3
ON

LOOP 1

LOOP 2 LOOP 1 LOOP 3

SERIAL #1 LOOP 4 SERIAL #2 LOOP 3

OF F 2

SERIAL #1 LOOP 2 SERIAL #1 LOOP 1 SERIAL #2 LOOP 2

LOOP 1

LOOP 1

3 4

LOOP 1

SERIAL #2 - LOOP 1 = ON + 4 BUTTONS LOOP 4 = 3 + 4 BUTTONS

5802 MN2
ENROLL AS "UR" OR "RF"

5804/5804E
ENROLL AS "BR"

5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR" SET HOUSE ID

5805-6
ENROLL AS "BR"

5806/5806W3 5808/5808LST/5808W3
ENROLL AS "RF"

5809
ENROLL AS "RF"

LOOP 2 (REED) LOOP 2 (REED) LOOP 1 LOOP 1 (TERMINALS) LOOP 2 (REED) LOOP 1 (TERMINALS) ALTERNATE POSITION FOR LOOP 2 LOOP 2 (REED) LOOP 1 (TERMINALS)

LOOP 1 (PRIMARY) LOOP 2 (AUX. CENTER) LOOP 3 (AUX. RIGHT) LOOP 1

5814
ENROLL AS "RF"

5815
ENROLL AS "RF"

5816
ENROLL AS "RF"

5816MN
ENROLL AS "RF"

5817
ENROLL AS "RF"

5818MNL
ENROLL AS "RF"

LOOP 2 (REED)

LOOP 2 (REED) LOOP 3 (TERMINALS) LOOP 1 (INTERNAL SHOCK SENSOR LOOP 1 LOOPS 1-3

AR ME D RE

AD Y

1+ -55 )/-

LOOP 1

LOOP 3 (TERMINALS)

LOOP 1 (TERMINALS)

5819
ENROLL AS "RF"

5819S (WHS & BRS)


ENROLL AS "RF"

5820/5820L
ENROLL AS "RF"

5821
ENROLL AS "RF"

5828/5828V
SET HOUSE ID

5853
ENROLL AS "RF"

SERIAL #1 LOOP 3
AW AY

SERIAL #1 LOOP 4 SERIAL #2 LOOP 3

ST AY 1 2 3 4

SERIAL #1 LOOP 2 SERIAL #1 LOOP 1 SERIAL #2 LOOP 2 LOOP 1 (MOTION) LOOP 1 LOOP 1

SERIAL #2 - LOOP 1 = ON + 4 BUTTONS LOOP 4 = 3 + 4 BUTTONS

5878
ENROLL AS "BR"

5890/5890PI
ENROLL AS "RF"

5894PI
ENROLL AS "RF"

5897-35
ENROLL AS "RF"
5800-003-V0

2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.firstalertprofessional.com
Copyright 2003 Honeywell International Inc.

K5305-5PRV5r