Manual Sharp
Manual Sharp
DIGITAL MULTIFUNCTIONAL
SYSTEM
OPERATION MANUAL
Page
INTRODUCTION
SETTING UP THE UNIT
LOADING PAPER
MAKING COPIES
SPECIAL FUNCTIONS
MAINTENANCE
TROUBLESHOOTING
THE UNIT
4
7
14
46
52
57
61
68
INSTALLING THE
SOFTWARE (AL-1641CS)
19
APPENDIX
AL-1631
AL-1641CS
MODEL
AL-1631/AL-1641CS
D IN CHINA
KS
SE1161QSZZ
03J
1
FOR YOUR PROTECTION...
To aid in reporting this unit in case of loss or theft, please record below the model number
and serial number located on the back of the unit. We also suggest you record all the
information listed and retain for future reference.
MODEL NUMBER SERIAL NUMBER
DATE OF PURCHASE
Dealer
Address City
State Zip Telephone
Service Station
Address City
State Zip Telephone
To obtain service, or to obtain product literature, accessories, or
supplies,
please call 1-(630)378-3590 in the USA
or 905-568-7140 in Canada.
For customer assistance, please visit http://www.sharpusa.com/
(for USA) or http://www.sharp.ca/ (for Canada) on the World Wide Web
or call 1-(630)378-3590 (for USA).
Do not make copies of anything which is prohibited from copying by law. The
following items are normally prohibited from copying by national law. Other
items may be prohibited by local law.
Money Stamps Bonds Stocks Bank drafts
Checks Passports Driver's licenses
1
CAUTIONS
Caution label on the unit
The label ( ) in the fusing area of the unit indicates the following:
: Caution, risk of danger
: Caution, hot surface
Cautions on using
Follow the cautions below when using this unit.
Warning:
The fusing area is hot. Exercise care in this area when removing misfed paper.
Do not look directly at the light source. Doing so may damage your eyes.
Do not switch the unit rapidly on and off. After turning the unit off, wait 10 to 15
seconds before turning it back on.
Unit power must be turned off before installing any supplies.
Caution:
Place the unit on a firm, level surface.
Do not install the unit in a humid or dusty location.
When the unit is not used for a long time, for example for consecutive holidays,
turn the power switch off and remove the power cord from the outlet.
When moving the unit, be sure to turn the power switch off and remove the power
cord from the outlet.
Do not cover the unit with a dust cover, cloth or plastic film while the power is on.
Doing so may prevent heat radiation, damaging the unit.
Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
The socket-outlet shall be installed near the unit and shall be easily accessible.
Important points when selecting an installation site
Do not install your unit in areas that are:
damp, humid, or very dusty
exposed to direct sunlight
poorly ventilated
subject to extreme temperature or humidity changes, e.g., near an air conditioner
or heater.
Be sure to allow the required space around the
machine for servicing and proper ventilation.
8" (20cm)
4"
(10cm)
4"
(10cm)
2
Cautions on handling
Be careful in handling the unit as follows to maintain the performance of this unit.
Do not drop the unit, subject it to shock or strike it against any object.
Do not expose the drum cartridge to direct sunlight.
Doing so will damage the surface (green portion) of the drum cartridge, causing
smudges on copies.
Store spare supplies such as drum cartridges and TD cartridges in a dark
place without removing from the package before use.
If they are exposed to direct sunlight, smudges on copies may result.
Do not touch the surface (green portion) of the drum cartridge.
Doing so will damage the surface of the cartridge, causing smudges on copies.
Trademark acknowledgements
Microsoft
Windows
95, Windows
98, Windows
Me, Windows NT
4.0, Windows
2000,
and Windows
Reader Copyright
63
8
MISFEED REMOVAL
When the misfeed ( ) indicator blinks or blinks in the display, the unit will
stop because of a misfeed. If a misfeed occurs when using the SPF, a number may
appear in the display after a minus sign. This indicates the number of the originals
that must be returned to the document feeder tray after a misfeed. Return the
required number of originals. Then this number will disappear when copying is
resumed or the clear ( ) key is pressed. When the SPF misfeeds an original
sheet, the unit will stop and the SPF misfeed ( ) indicator will blink, while the
misfeed ( ) indicator will remain off. For a misfeed of originals in the SPF, see "D:
Misfeed in the SPF" (p.67).
1
Open the multi-bypass tray, and side cover, in that order.
To open the multi-bypass tray, see "The multi-bypass tray" (p.17). To open
the side cover, see "INSTALLING THE TD CARTRIDGE" (p.10).
2
Check the misfeed location. Remove the misfed paper
following the instructions for each location in the illustration
below. If the misfeed ( ) indicator blinks, proceed to "A:
Misfeed in the paper feed area" (p.64).
If paper is misfed here, proceed to "A:
Misfeed in the paper feed area". (p.64)
If paper is misfed here, proceed to "B:
Misfeed in the fusing area". (p.65)
If the misfed paper is seen from
this side, proceed to "C: Misfeed
in the transport area". (p.66)
64
A: Misfeed in the paper feed area
1
Gently remove the misfed paper from the paper feed area as
shown in the illustration. When the misfeed ( ) indicator
blinks, and the misfed paper is not seen from the paper feed
area, pull out the paper tray and remove the misfed paper. If the
paper cannot be removed, proceed to "B: Misfeed in the fusing
area".
2
Close the side cover by pressing the round projections near
the side cover open button. The misfeed ( ) indicator will go
out and the start ( ) indicator will light up.
The fusing unit is hot. Do not touch the fusing unit when
removing misfed paper. Doing so may cause a burn or other
injury.
Do not touch the surface of the drum (green portion) of the
drum cartridge when removing the misfed paper. Doing so
may damage the drum and cause smudges on copies.
If the paper has been fed through the multi-bypass tray, do
not remove the misfed paper through the multi-bypass tray.
Toner on the paper may stain the paper transport area,
resulting in smudges on copies.
65
8
B: Misfeed in the fusing area
1
Lower the fusing unit release
lever.
2
Gently remove the misfed paper
from under the fusing unit as
shown in the illustration. If the
paper cannot be removed, proceed
to "C: Misfeed in the transport
area".
3
Raise the fusing unit release lever and then close the side
cover by pressing the round projections near the side cover
open button. The misfeed ( ) indicator will go out and the start
( ) indicator will light up.
The fusing unit is hot. Do not
touch the fusing unit when
removing misfed paper. Doing
so may cause a burn or other
injury.
Do not touch the surface of the drum (green portion) of the
drum cartridge when removing the misfed paper. Doing so
may cause smudges on copies.
Do not remove the misfed paper from above the fusing unit.
Unfixed toner on the paper may stain the paper transport
area, resulting in smudges on copies.
Fusing unit release lever
66
C: Misfeed in the transport area
1
Lower the fusing unit release lever.
See "B: Misfeed in the fusing area" (p.65).
2
Open the front cover.
To open the front cover, see "INSTALLING THE TD CARTRIDGE" (p.10).
3
Rotate the roller rotating
knob in the direction of the
arrow and gently remove
the misfed paper from the
exit area.
4
Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections
near the side cover open button. The misfeed ( ) indicator will
go out and the start ( ) indicator will light up.
When closing the covers, be sure to close the front cover securely and
then close the side cover. If the covers are closed in the wrong order,
the covers may be damaged.
Roller rotating knob
67
8
D: Misfeed in the SPF
An original misfeed may occur at one of three locations: if the misfed original is seen
from the document feeder tray, (A) in the document feeder tray; if the misfed original
is not seen from the document feeder tray, (B) in the exit area or (C) under the
document feeder cover. Remove the misfed original following the instructions for
each location.
(A) Open the document feeder cover and pull the original gently to the left and
out from the document feeder tray. Close the document feeder cover. Open
and close the SPF to clear the SPF misfeed ( ) indicator. If the misfed
original cannot be easily removed, proceed to (C).
(B) Open the SPF and rotate the roller to remove the misfed original from the
exit area. If the misfed original cannot be easily removed, proceed to (C).
(C) If the original does not move easily into the exit area, remove it in the
direction of the arrow while rotating the knob.
A number may appear in the display after a minus sign, indicating the
number of the originals that must be returned to the document feeder
tray. Open and close the SPF to clear the SPF misfeed ( ) indicator,
and then return the required number of originals. Then press the start
( ) key to resume copying.
Document feeder cover
Roller
68
SPECIFICATIONS
Model AL-1631 AL-1641CS
Type
Digital laser copier,
desk-top type
Digital multifunctional
system, desk-top type
Copy/printer system Dry, electrostatic transfer
Originals Sheets, bound documents
Printer function Available
Scanner function Available
Paper tray 250 sheets
Single bypass, Multi-bypass tray Multi-bypass tray (50 sheets)
Paper output tray 100 sheets
SPF SPF
Original sizes
Document
glass/SPF
Max. 8-1/2" x 14"
Original feed
Document glass 1 sheet
SPF Up to 30 sheets
Copy/printing size 3-1/2" x 5-1/2" to 8-1/2" x 14" *
1
Image loss
Max. 5/32" (4mm) *
2
Max. 11/64" (4.5mm) *
3
Copy speed 16 pages/min. (8-1/2" X 11")
Print speed 12 pages/min. (8-1/2" X 11")
Continuous copying/printing Max. 99 pages subtractive counter
First-copy/print time
(Approximately)
9.6 seconds *
4
(paper:A4, exposure mode: AUTO, copy ratio:100% )
Copy ratio
Variable: 25% to 400% in 1% increments (total 376 steps)
Fixed: 25%, 64%, 78%, 100%, 129%, 400%
Exposure
system
Document glass
Moving optical source, slit exposure (stationary platen)
with automatic exposure
SPF Moving original
Fusing system Heat rollers
Development system Magnetic brush development
Light source Cold cathode fluorescent lamp
Resolution
Copier
600 x 300dpi (Auto/Manual mode)
600 x 600dpi (Photo mode)
Printer 600dpi
Scanner 600 x 1200dpi
Gradation
Scan 256 levels
Output 2 levels
Bit depth 1 bit or 8 bit/pixel
Sensor Color CCD
9
APPENDIX
69
9
*
1
Feed paper lengthwise only.
*
2
Leading and trailing edges.
*
3
Along the other edges in totals.
*
4
Data transmission time is not included. (Only for printer)
*
5
Not includes TD and drum cartridges.
Scanning speed Max. 2.88ms/line
Memory 8 MB
Power supply 120V, 60Hz, 9.5A
Power consumption Max. 1.0kW
Overall
dimensions
Width 23.9" (607.6mm)
Depth 19.4" (492.5mm)
Weight (Approximately) *
5
41.9 lbs. (19kg)
Unit dimensions
Width 20.4" (518mm)
Depth 19.4" (492.5mm)
Height 15.0" (380.4mm)
Operating conditions
Temperature: 50F to 86F (10C to 30C)
Humidity: 20% to 85%
Emulation SHARP GDI
Interface port
USB interface (USB1.1
Standard) /
IEEE1284-compliant bi-
directional parallel interface
(Only for printer)
Noise level
Sound Power Level LwA (1B=10dB)
Copying: 6.0 [B]
Standby: 3.4 [B]
Sound Pressure Level LpA (bystander positions)
Copying: 47 [dB (A)]
Standby: 19 [dB (A)]
Sound Pressure Level LpA (operator position)
Copying: 50 [dB (A)]
Standby: 21 [dB (A)]
Noise emission measurement in accordance with ISO 7779.
Emission concentration
(measurement according to
RAL-UZ 62)
Ozone: less than 0.02 mg/m
3
Dust: less than 0.075 mg/m
3
Styrene: less than 0.07 mg/m
3
As a part of our policy of continuous improvement, SHARP reserves the
right to make design and specification changes for product improvement
without prior notice. The performance specification figures indicated are
nominal values of production units. There may be some deviations from
these values in individual units.
Model AL-1631 AL-1641CS
70
ABOUT SUPPLIES AND OPTIONS
When ordering supplies, please use the correct part numbers as listed below.
Supply list
* Based on copying onto letter-type paper at 5% toned area
(The life of the TD cartridge which has been included in the unit at the factory is
approximately 2,000 sheets.)
Interface cable
Please purchase the appropriate cable for your computer.
Parallel interface cable
IEEE 1284-Shielded type bi-directional parallel interface cable (6 feet Max.)
USB interface cable
Shielded twisted pair cable, high-speed transmission equivalent (6 feet Max.)
Be sure to use only genuine SHARP parts and supplies.
For best copying results, be sure to use only SHARP Genuine
Supplies which are designed, engineered, and tested to maximize the
life and performance of SHARP copiers. Look for the Genuine
Supplies label on the toner package.
Supply Part number Usable life
TD cartridge AL-110TD Approx. 4,000 sheets *
Drum cartridge AL-100DR Approx. 18,000 sheets
71
9
MOVING AND STORING THE UNIT
Moving instructions
When moving the unit, follow the procedure below.
1
Turn the power switch off and remove the power cord from the
outlet.
2
Open the side cover and front cover, in that order. Remove the
TD cartridge and close the front cover and side cover, in that
order.
To open and close the side cover and front cover, and to remove the TD
cartridge, see "TD CARTRIDGE REPLACEMENT" (p.57).
3
Raise the handle of the paper tray and pull the paper tray out
until it stops.
4
Push the center of the pressure plate down until it locks in
place and lock the plate using the pressure plate lock which
has been stored in the front of the paper tray.
5
Push the paper tray back into the unit.
6
Lock the scan head locking switch (p.9).
7
Close the multi-bypass tray and the paper output tray
extension, and attach the packing materials and tape which
were removed during installation of the unit. See "PREPARING
THE UNIT FOR INSTALLATION" (p.8).
8
Pack the unit into the carton. See "CHECKING PACKED
COMPONENTS AND ACCESSORIES" (p.8).
Proper storage
Store the supplies in a location that is:
clean and dry,
at a stable temperature,
not exposed to direct sunlight
Store paper in the wrapper and lying flat.
Paper stored out of the wrapper or in packages standing on end may curl or get
damp, resulting in paper misfeeds.
When moving this unit, be sure to remove the TD cartridge in advance.
When shipping the unit, the scan head locking switch must be locked to
prevent shipping damage.
72
SOFTWARE LICENSE
PLEASE READ THIS LICENSE CAREFULLY BEFORE USING THE SOFTWARE. BY
USING THE SOFTWARE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF
THIS LICENSE.
1. License.
The application, demonstration, system and other software accompanying this License, whether on disk,
in read only memory, or on any other media (the "Software") and related documentation are licensed to
you by SHARP. You own the disk on which the Software is recorded but SHARP and/or SHARP'S
Licensors retain title to the Software and related documentation. This License allows you to use the
Software on one or more computers connected to a single printer and make one copy of the Software in
machine-readable form for backup purposes only. You must reproduce on such copy the SHARP
copyright notice, the copyright notice of SHARPS Licensors and any other proprietary legends of
SHARP and/or its Licensors that were on the original copy of the Software. You may also transfer all
your license rights in the software, the backup copy of the Software, the related documentation and a
copy of this License to another party, provided the other party reads and agrees to the terms and
conditions of this License.
2. Restrictions.
The Software contains copyrighted material, trade secrets and other proprietary material which is owned
by SHARP and/or its Licensors and in order to protect them you may not decompile, reverse engineer,
disassemble or otherwise reduce the Software to a human-perceivable form. You may not modify,
network, rent, lease, loan, distribute or create derivative works based upon the Software in whole or in
part. You may not electronically transmit the Software from one computer to another or over a network.
3. Termination.
This license is effective until terminated. You may terminate this License at any time by destroying the
Software and related documentation and all copies thereof. This License will terminate immediately
without notice from SHARP and/or SHARPS Licensors if you fail to comply with any provision of this
License. Upon termination you must destroy the Software and related documentation and all copies
thereof.
4. Export Law Assurances.
You agree and certify that neither the Software nor any other technical data received from SHARP, nor the
direct product thereof, will be exported outside the United States except as authorized and as permitted by
the laws and regulations of the United States. If the Software has been rightfully obtained by you outside
of the United States, you agree that you will not re-export the Software nor any other technical data
received from SHARP, nor the direct product thereof, except as permitted by the laws and regulations of
the United States and the laws and the regulation of the jurisdiction in which you obtained the Software.
5. Government End Users.
If you are acquiring the Software on behalf of any unit or agency of the United States Government, the
following provisions apply. The Government agrees:
(i) if the Software is supplied to the Department of Defense (DoD), the Software is classified as
"Commercial Computer Software" and the Government is acquiring only "restricted rights" in the
Software and its documentation as that term is defined in Clause 252.227-7013 (c)(1) of the
DFARS; and
(ii) if the Software is supplied to any unit or agency of the United States Government other than DoD,
the Government's rights in the Software and its documentation will be as defined in Clause 52.227-
19 (c)(2) of the FAR or, in the case of NASA, in Clause 18-52.227-86 (d) of the NASA
Supplement to the FAR.
73
6. Limited Warranty on Media.
SHARP warrants the disks on which the Software is recorded to be free from defects in materials and
workmanship under normal use for a period of ninety (90) days from the date of purchase as evidenced by
a copy of the receipt. The entire liability of SHARP and/or its Licensors and your exclusive remedy will
be replacement of the disk which fails to meet the limited warranty provided by this Clause 6. A disk will
be replaced when it is returned to SHARP or a SHARP authorized representative with a copy of the
receipt. SHARP will have no responsibility to replace a disk damaged by accident, abuse or
misapplication.
ANY IMPLIED WARRANTIES ON THE DISKS, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN
DURATION TO NINETY (90) DAYS FROM THE DATE OF DELIVERY. THIS WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM JURISDICTION TO JURISDICTION.
7. Disclaimer of Warranty on Software.
You expressly acknowledge and agree that use of the Software is at your sole risk. The software and
related documentation are provided "AS IS" and without warranty of any kind and SHARP and SHARP'S
Licensor(s) (for the purpose of provisions 7 and 8, SHARP and SHARP'S Licensor(s) shall be
collectively referred to as "SHARP") EXPRESSLY DISCLAIM ALL WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SHARP DOES NOT
WARRANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILL MEET YOUR
REQUIREMENTS, OR THAT THE OPERATION OF THE SOFTWARE WILL BE
UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTS IN THE SOFTWARE WILL BE
CORRECTED. FURTHERMORE, SHARP DOES NOT WARRANT OR MAKE ANY
REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE OF THE
SOFTWARE OR RELATED DOCUMENTATION IN TERMS OF THEIR CORRECTNESS,
ACCURACY, RELIABILITY, OR OTHERWISE. NO ORAL OR WRITTEN INFORMATION OR
ADVICE GIVEN BY SHARP OR A SHARP AUTHORIZED REPRESENTATIVE SHALL CREATE A
WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY. SHOULD THE
SOFTWARE PROVE DEFECTIVE, YOU (AND NOT SHARP OR A SHARP AUTHORIZED
REPRESENTATIVE) ASSUME THE ENTIRE COST OF ALL NECESSARY SERVICING, REPAIR
OR CORRECTION, SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED
WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
8. Limitation of Liability.
UNDER NO CIRCUMSTANCES INCLUDING NEGLIGENCE, SHALL SHARP BE LIABLE FOR
ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES THAT RESULT FROM THE
USE OR INABILITY TO USE THE SOFTWARE OR RELATED DOCUMENTATION, EVEN IF
SHARP OR A SHARP AUTHORIZED REPRESENTATIVE HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. SOME JURISDICTIONS DO NOT ALLOW THE
LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
In no event shall SHARP'S total liability to you for all damages, losses, and causes of action (whether in
contract, tort (including negligence) or otherwise) exceed the amount paid by you for the Software.
9. Controlling Law and Severability.
For a portion of the Software related with Apple Macintosh and Microsoft Windows, this license shall be
governed by and construed in accordance with the laws of the state of California and Washington,
respectively. If for any reason a court of competent jurisdiction finds any provision of this License, or
portion thereof, to be unenforceable, that provision of the License shall be enforced to the maximum
extent permissible so as to effect the intent of the parties, and the remainder of this License shall continue
in full force and effect.
10. Complete Agreement.
This License constitutes the entire agreement between the parties with respect to the use of the Software and
related documentation, and supersedes all prior or contemporaneous understandings or agreements, written
or oral, regarding such subject matter. No amendment to or modification of this License will be binding
unless in writing and signed by a duly authorized representative of SHARP.
74
IMPORTANT SERVICE INFORMATION (U.S.A. only)
If a Problem Occurs
Most operational questions can be answered by referring to the Operation Manual or Online Manual.
Also, for your convenience, you will find answers to frequently asked questions on our website at
www.sharpusa.com. You can also e-mail your service question to
[email protected]. Should you require further assistance, call Sharp at 1-630-
378-3590. A Customer Relations Specialist will assist you. Before your call, please be ready to provide
the model number of your Product, Serial Number, Date of Purchase, description of the problem, and a
valid Credit Card Number (should it be required).
How Exchange is Obtained
A replacement unit in exchange for your copier is provided directly by Sharp to any U.S. location. You
will be required to provide consent for acceptance of an exchange unit and provide credit card
authorization for the value of the exchange unit and the outbound shipping cost. At that time, Sharp will
ship to you an exchange for your defective Product. The exchange unit we ship to you will be new or
remanufactured. Upon your receipt of the exchange unit, packing and shipping instructions will be
enclosed for you to return the defective unit. Upon Sharp's receipt of the defective unit, your credit card
hold for the exchange unit will be released.
How Warranty Repair Service is Obtained
If you prefer that we repair your unit instead of replacing it, our Customer Relations Specialists at 1-630-
378-3590 will explain how to obtain warranty repair service. Please be sure to retain the original
packaging materials in order to facilitate shipment. The shipment of the defective unit will be at your
expense; please be sure it is insured and packaged securely. Upon repair of your unit, Sharp will promptly
return it to you at any U.S. location.
What You Must Do
Your Product is designed to perform with a minimum amount of user maintenance. However, you are
responsible for the required user maintenance described in the Operation Manual. This requires user
maintenance including replacement of the TD cartridge and drum cartridge, cleaning of the unit and
transfer charger, removal of dust and foreign matter, clearing of paper misfeeds, and proper routine and
preventive maintenance.
Service After Expiration of Warranty Coverage
Should you require service repair after warranty coverage has expired, contact Sharp at 1-630-378-3590
for information.
75
END-USER LIMITED WARRANTY (Valid in U.S.A. only)
SHARP ELECTRONICS CORPORATION warrants to the first end-user purchaser that this Sharp brand
product (the "Product"), when shipped in its original container, will be free from defective workmanship
and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product
or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for
the period(s) set forth below.
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s)
set forth below nor to any Product the exterior of which has been damaged or defaced, which has been
subjected to improper voltage or other misuse, abnormal service or handling, or which has been altered or
modified in design or construction.
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth
below and provide proof of purchase to the servicer.
To the extent permitted by applicable state law, the warranties set forth herein are in lieu of, and exclusive
of, all other warranties, express or implied. Specifically, ALL OTHER WARRANTIES OTHER THAN
THOSE SET FORTH ABOVE ARE EXCLUDED. ALL EXPRESS AND IMPLIED WARRANTIES
INCLUDING THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR USE, AND FITNESS
FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED. If, under applicable state law,
implied warranties may not validly be disclaimed or excluded, the duration of such implied warranties is
limited to the period(s) from the date of purchase set forth below.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other
than those described herein, or to extend the duration of any warranties beyond the time period described
herein on behalf of Sharp.
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be
the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the
period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of
Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims,
whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in
any way responsible, for any damages or defects in the Product which were caused by repairs or attempted
repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way
responsible for any incidental or consequential economic or property damage. Some states do not allow
limits on warranties or on remedies for breach in certain transactions; in such states, the limits herein may
not apply.
Model Specific Section
Your Product Model Number & Description: AL-1631 Digital Laser Copier
AL-1641CS Digital Multifunctional System
(Be sure to have this information available when you need
service for your Product.)
Warranty Period for this Product: One (1) year on parts and one (1) year on labor from date of
purchase, except for the toner/developer cartridge and drum
cartridge supplied with the Product, which are warranted for a
period of fifteen (15) days from date of purchase. Disk media
supplied with the Product is warranted for replacement only
and limited to ninety (90) days from date of purchase.
Additional Item(s) Excluded from The warranty does not apply to defects or damage resulting
Warranty Coverage (if any): from improper or inadequate maintenance by the purchaser
(see Operation Manual) or the use of non-genuine Sharp
toner/developer and drum cartridges.
Where to Obtain Service: Service is available in the United States from Sharp. You may
ship in your Product for repair or replacement. Replacement
units may be remanufactured, rather than new, but your
original limited warranty will continue for the remainder of
your original warranty period or ninety (90) days from the
date we send the replacement unit to you, whichever is longer.
What to do to Obtain Service: Call Sharp at 1-630-378-3590 to obtain a Return
Authorization Number and shipping instructions. A
technician will work with you on the phone and if it is
determined that your Product needs service, you will have
your choice of having your unit repaired or replaced to any
U.S. location. Be sure to have Proof of Purchase available.
MATERIAL SAFETY DATA SHEET
Data Revised: Jul. 31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-00831
76
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name : AL-100TD / DM-150TD / AL-110TD / AL-110DC (Black Toner)
Supplier Identification : Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
2. COMPOSITION/INFORMATION ON INGREDIENTS
Substance[ ] Preparation[X]
*EC N0. : 400-110-2, Symbol letter : F, R Phrase : R11
Area (Country) (Name and Telephone Number)
North
America
U.S.A. Sharp Electronics Corporation
Sharp Plaza, Mahwah, NJ
Telephone number for information : 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number : 1-800-255-3924
Oceania
Australia Sharp Corporation of Australia PTY. Ltd.
No1 Huntingwood Drive Huntingwood Blacktown N.S.W.
Telephone number for information : 1300-13-50-22
Europe
Germany Sharp Electronics (Europe) GMBH
Sonninstrasse 3, 20097 Hamburg
Telephone number to access MSDS : 040-2376-2185
For more information : 040-2376-2613
United
Kingdom
Sharp Electronics (U. K.) Ltd.
Telephone number for information : 08705-274-277
France Sharp Electronics France S.A.
Telephone number for information : 01-49-90-34-00
Austria Sharp Electronics GMBH
Telephone number for information : 01-727-19-0
Italy Sharp Electronics (Italia) S.P.A.
Telephone number for information : 02895951
Spain Sharp Electronics Espana S.A.
Telephone number for information : 93-581-97-00
Netherlands Sharp Electronics Benelux B.V.
Telephone number for information : 30-6359500
Sweden Sharp Electronics (Nordic) AB
Telephone number for information : 08-634-36-00
Switzerland Sharp Electronics(Schweiz)AG
Telephone number for information : 01-846-6111
Middle
East
U.A.E Sharp Middle East FZE
P.O.Box 17115 Jebel Ali, Dubai
Telephone number for information : 04-815311
Ingredient CAS No. Proportion OSHA PEL ACGIH TLV MAK-TWA NOHSC-TWA
Styrene-Acrylate
copolymer
29497-14-1 35-45% Not listed Not listed Not listed Not listed
Styrene-
homopolymer
9003-53-6 35-45% Not listed Not listed Not listed Not listed
Carbon black 1333-86-4 5-10% 3.5mg/m
3
3.5mg/m
3
Not listed 3mg/m
3
Iron oxide 1309-38-2 5-10% Not listed Not listed Not listed Not listed
Polypropylene 9010-79-1 1-5% Not listed Not listed Not listed Not listed
parafrfine 8002-74-2 1-5% Not listed Not listed Not listed Not listed
Metal Complex dye* 109125-51-1
84179-66-8
<1% 0.5mg/m
3
0.5mg/m
3
Not listed Not listed
Page: 1/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul. 31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-00831
77
3. HAZARDS IDENTIFICATION
Most Important Hazards and Effects of the Products
Human Health Effects : There are no anticipated carcinogenic effects from exposure based on
animal tests performed using toner. When used as intended according to
instructions, studies do not indicate any symptoms of fibrosis will occur.
Environmental Effects : No data are available.
Specific hazards :Dust explosion (like most finely divided organic powders)
Directive 1999/45/EC(Europe) :Not classified as dangerous
4. FIRST-AID MEASURES
Route(s) of Entry :Inhalation? Skin? Ingestion?
Yes No Possible but very unusual.
Inhalation : Remove to fresh air. If symptoms occur, consult medical personnel.
Skin Contact : Wash with soap and water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact : Flush eyes immediately with water for 15 minutes. If irritation does occur,
consult medical personnel.
Ingestion : Rinse with water and drink several glasses of water. If irritation or discomfort
does occur, consult medical personnel.
5. FIRE -FIGHTING MEASURES
Extinguishing Media : water, CO
2
, foam and dry chemicals
Special Fire fighting Procedures : None
Fire and Explosion Hazards : Toner material, like most finely divided organic powders,
may form an explosive mixture.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions :None
Environmental Precautions :None
Methods for Cleaning Up :Wipe off with paper or cloth. Do not use vacuum cleaner when a
large amount is released. It, like most finely divided organic
powders, is capable of creating a dust explosion.
7. HANDLING AND STORAGE
Handling
Technical Measures :None
Precautions :None
Safe Handling Advice :Use of a dust mask is recommended when handling a large quantity of
toner or during long term exposure, as with any non-toxic dust. Try not
to disperse the particles.
Storage
Technical Measures :None
Storage Conditions :Keep container closed and Store in a cool and dry place.
Keep out of the reach of children.
Incompatible Products:None
Page: 2/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul. 31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-00831
78
8. EXPOSURE CONTROL / PERSONAL PROTECTION
Engineering Measures
Ventilation :None required with intended use.
Exposure limit values
OSHA-PEL (USA) :15mg/m
3
(Total Dust) , 5mg/m
3
(Respirable Dust)
ACGIH-TLV (USA) :10mg/m
3
(Total Dust) , 3mg/m
3
(Respirable Dust)
Personal Protective Equipment
Respiratory Protection :Not required under intended use.
Hand Protection :Not required under intended use.
Eye Protection :Not required under intended use.
Skin Protection :Not required under intended use.
Other Protective equipment :Use of a dust mask and goggles are recommended when
handling a large quantity of toner or during long term exposure,
as with any non-toxic dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State : Solid Form: Powder Color: Black Odor: odorless
Ph :Not applicable
Boiling/Melting Point :Not applicable
Softening Point (C) :No data
Flash Point (C ) :Not applicable
Ignition Point (C ) :No data
Explosion Properties :No data
Density (g/cm
3
) :1.1 (bulk density : 0.34)
Solubility in water :Negligible
10. STABILITY AND REACTIVITY
Stability : Stable
Hazardous Reactions : Dust explosion, like most finely divided organic powders.
Conditions to avoid : Electric discharge, throwing into fire.
Materials to avoid : Oxidizing Materials
Hazardous Decomposition Products: CO, CO
2
and NO
X
Further Information : None
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion (oral) : LD
50
>2000mg/kg (Rats)
Dermal : LD
50
>2000mg/kg (Rats)
Inhalation : No data
Eye irritation : Not an irritant
Skin irritation : Not an irritant
Skin sensitizer : No sensitization
Mutagenicity : Negative (Ames Test)
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible
human carcinogen). This classification is given to chemicals for which there is
inadequate human evidence, but sufficient animal evidence on which to base an
opinion of carcinogenicity. The classification is based upon the development of
lung tumors in rats receiving chronic inhalation exposures to free carbon black at
levels that induce particle overload of the lung. Studies performed in animal
models other than rats did not show any association between carbon black and
lung tumors. Moreover, a two-year cancer bioassay using a typical toner
preparation containing carbon black demonstrated no association between toner
exposure and tumor development in rats.
Page: 3/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul. 31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-00831
79
Chronic Effect : In a study in rats of chronic inhalation exposure to a typical toner, a mild to
moderate degree of lung fibrosis was observed in 92% of the rats in the high
concentration (16mg/m
3
) exposure group, and a minimal to mild degree of
fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
)
exposure group, the most relevant level to potential human exposures.
12. ECOLOGICAL INFORMATION
No data are available.
13. DISPOSAL CONSIDERATION
Waste from residues :Waste material may be dumped or incinerated under conditions
which meet all federal, state and local environmental regulations.
Contaminated Packaging:Waste may be disposed or incinerated under conditions which meet
all federal, state and local environmental regulations.
14. TRANSPORT INFORMATION
UN Classification :None
Not classified as hazardous for transport.
15. REGULATORY INFORMATION
US Information
TSCA (Toxic Substances Control Act) :
All chemical substances in this product comply with all applicable rules or order under TSCA.
SARA (Superfund Amendments and Reauthorization Act) Title III
302 Extreme Hazardous Substance :None
311/312 Hazard Classification :None
EU Information
1999/45/EC and 67/548/EEC
Symbol & Indication :Not required
R-Phrase :Not required
76/769/EEC :All chemical substances in this product comply with all applicable rules or order
under 76/769/EEC.
16. OTHER INFORMATION
NFPA Rating (USA) :Health=1 Flammability=1 Reactivity=0
WHMIS Legislation (Canada) :This product is not a controlled product.
List of R phrases :R11 : Highly flammable
References
IARC (1996) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process And Printing Inks, Carbon Black and Some
Nitro Compounds, Lyon, pp.149-261
H.Muhle, B.Bellmann, O.Creutzenberg, C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie,
P.Morrow, U.Mohr,
S.Takenaka, and R.Mermelstein (1991) Pulmonary Response to Toner upon Chronic
Inhalation Exposure in Rats.
Fundamental and Applied Toxicology 17, pp.280-299.
The information on this data sheet represents our current data and best opinion as to the proper
use in handling of this product under normal conditions. However, all materials may present
unknown hazards and should be used with caution. Although certain hazards are described
herein, we do not guarantee that these are the only hazards which exist.
Page: 4/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul .31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-30831
80
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name : AL-100TD / DM-150TD / AL-110TD / AL-110DC (Black Developer)
Supplier Identification : Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
2. COMPOSITION/INFORMATION ON INGREDIENTS
Substance[ ] Preparation[X]
Area (Country) (Name and Telephone Number)
North
America
U.S.A. Sharp Electronics Corporation
Sharp Plaza, Mahwah, NJ
Telephone number for information : 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number : 1-800-255-3924
Oceania
Australia Sharp Corporation of Australia PTY. Ltd.
No1 Huntingwood Drive Huntingwood Blacktown N.S.W.
Telephone number for information : 1300-13-50-22
Europe
Germany Sharp Electronics (Europe) GMBH
Sonninstrasse 3, 20097 Hamburg
Telephone number to access MSDS : 040-2376-2185
For more information : 040-2376-2613
United
Kingdom
Sharp Electronics (U. K.) Ltd.
Telephone number for information : 08705-274-277
France Sharp Electronics France S.A.
Telephone number for information : 01-49-90-34-00
Austria Sharp Electronics GMBH
Telephone number for information : 01-727-19-0
Italy Sharp Electronics (Italia) S.P.A.
Telephone number for information : 02895951
Spain Sharp Electronics Espana S.A.
Telephone number for information : 93-581-97-00
Netherlands Sharp Electronics Benelux B.V.
Telephone number for information : 30-6359500
Sweden Sharp Electronics (Nordic) AB
Telephone number for information : 08-634-36-00
Switzerland Sharp Electronics(Schweiz)AG
Telephone number for information : 01-846-6111
Middle
East
U.A.E Sharp Middle East FZE
P.O.Box 17115 Jebel Ali, Dubai
Telephone number for information : 04-815311
Ingredient CAS No. Proportion OSHA PEL ACGIH TLV MAK-TAK NOHSC-TWA
Iron powder 7439-89-6 85-95% Not listed Not listed Not listed Not listed
Styrene-Acrylate
copolymer
29497-14-1 1-5% Not listed Not listed Not listed Not listed
Styrene
homopolymer
9003-53-6 1-5% Not listed Not listed Not listed Not listed
Carbon black 1333-86-4 < 1% 3.5mg/m
3
3.5mg/m
3
Not listed 3.5mg/m
3
Page: 1/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul .31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-30831
81
3. HAZARDS IDENTIFICATION
Most Important Hazards and Effects of the Products
Human Health Effects : There are no anticipated carcinogenic effects from exposure based on
animal tests performed using toner. When used as intended according to
instructions, studies do not indicate any symptoms of fibrosis will occur.
Environmental Effects : No data are available.
Specific hazards :Dust explosion (like most finely divided organic powders)
Directive 1999/45/EC(Europe) :Not classified as dangerous
4. FIRST-AID MEASURES
Route(s) of Entry :Inhalation? Skin? Ingestion?
Yes No Possible but very unusual.
Inhalation : Remove to fresh air. If symptoms occur, consult medical personnel.
Skin Contact : Wash with soap and water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact : flush eyes immediately with water for 15 minutes. If irritation does occur,
consult medical personnel.
Ingestion : Rinse with water and drink several glasses of water . If irritation or discomfort
does occur, consult medical personnel.
5. FIRE -FIGHTING MEASURES
Extinguishing Media : water, CO
2
, foam and dry chemicals
Special Fire fighting Procedures:None
Fire and Explosion Hazards : Toner material, like most finely divided organic powders, it
may form an explosive mixture.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions :None
Environmental Precautions :None
Methods for Cleaning Up :Wipe off with paper or cloth. Do not use vacuum cleaner when a
large amount is released. It, like most finely divided organic
powders, is capable of creating a dust explosion.
7. HANDLING AND STORAGE
Handling
Technical Measures :None
Precautions :None
Safe Handling Advice :Use of a dust mask is recommended when handling a large quantity of
toner or during long term exposure, as with any non-toxic dust. Try not
to disperse the particles.
Storage
Technical Measures :None
Storage Conditions :Keep container closed and Store in a cool and dry place.
Keep out of the reach of children.
Incompatible Products:None
8. EXPOSURE CONTROL / PERSONAL PROTECTION
Engineering Measures
Ventilation :None required with intended use.
Exposure limit values
OSHA-PEL (USA) :15mg/m
3
(Total Dust) , 5mg/m
3
(Respirable Dust)
ACGIH-TLV (USA) :10mg/m
3
(Total Dust) , 3mg/m
3
(Respirable Dust)
Page: 2/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul .31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-30831
82
Personal Protective Equipment
Respiratory Protection :Not required under intended use.
Hand Protection :Not required under intended use.
Eye Protection :Not required under intended use.
Skin Protection :Not required under intended use.
Other Protective equipment :Use of a dust mask and goggles are recommended when
handling a large quantity of toner or during long term exposure,
as with any non-toxic dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State : Solid Form: Powder Color: Black Odor: odorless
Ph :Not applicable
Boiling/Melting Point :Not applicable
Flash Point (C ) :Not applicable
Explosion Properties :No data
Density (g/cm
3
) :5.4 (bulk density : 2.09)
Solubility in water :Negligible
10. STABILITY AND REACTIVITY
Stability : Stable
Hazardous Reactions : Dust explosion, like most finely divided organic powders.
Conditions to avoid : Electric discharge, throwing into fire.
Materials to avoid : Oxidizing Materials
Hazardous Decomposition Products: CO, CO
2
and NO
X
Further Information : None
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion (oral) : LD
50
>2000mg/kg (Rats) (Estimated from the constituent components)
Dermal : LD
50
>2000mg/kg (Rats)
Inhalation : No data
Eye irritation : Not an irritant (Rabbits)
Skin irritation : Not an irritant (Rabbits)
Skin sensitizer : No sensitization
Mutagenicity : Negative (Ames Test)
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen
(possible human carcinogen). This classification is given to chemicals for
which there is inadequate human evidence, but sufficient animal evidence
on which to base an opinion of carcinogenicity. The classification is based
upon the development of lung tumors in rats receiving chronic inhalation
exposures to free carbon black at levels that induce particle overload of the
lung. Studies performed in animal models other than rats did not show any
association between carbon black and lung tumors. Moreover, a two-year
cancer bioassay using a typical toner preparation containing carbon black
demonstrated no association between toner exposure and tumor
development in rats.
Chronic Effect : In a study in rats of chronic inhalation exposure to a typical toner, a mild to
moderate degree of lung fibrosis was observed in 92% of the rats in the high
concentration (16mg/m
3
) exposure group, and a minimal to mild degree of
fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
)
exposure group, the most relevant level to potential human exposures.
Page: 3/4
MATERIAL SAFETY DATA SHEET
Data Revised: Jul .31, 2002
Data Issued: Jun. 1, 1998
MSDS NO. F-30831
83
12. ECOLOGICAL INFORMATION
No data are available.
13. DISPOSAL CONSIDERATION
Waste from residues :Waste material may be dumped or incinerated under conditions
which meet all federal, state and local environmental regulations.
Contaminated Packaging:Waste may be disposed or incinerated under conditions which meet
all federal, state and local environmental regulations.
14. TRANSPORT INFORMATION
UN Classification :None
Not classified as hazardous for transport.
15. REGULATORY INFORMATION
US Information
TSCA (Toxic Substances Control Act) :
All chemical substances in this product comply with all applicable rules or order under TSCA.
SARA (Superfund Amendments and Reauthorization Act) Title III
302 Extreme Hazardous Substance :None
311/312 Hazard Classification :None
EU Information
1999/45/EC and 67/548/EEC
Symbol & Indication :Not required
R-Phrase :Not required
76/769/EEC :All chemical substances in this product comply with all applicable rules or order
under 76/769/EEC.
16. OTHER INFORMATION
NFPA Rating (USA) :Health=1 Flammability=1 Reactivity=0
WHMIS Legislation (Canada) :This product is not a controlled product.
References
IARC (1996) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process And Printing Inks, Carbon Black and Some
Nitro Compounds, Lyon, pp.149-261
H.Muhle, B.Bellmann, O.Creutzenberg, C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie,
P.Morrow, U.Mohr,
S.Takenaka, and R.Mermelstein (1991) Pulmonary Response to Toner upon Chronic
Inhalation Exposure in Rats.
Fundamental and Applied Toxicology 17, pp.280-299.
The information on this data sheet represents our current data and best opinion as to the proper
use in handling of this product under normal conditions. However, all materials may present
unknown hazards and should be used with caution. Although certain hazards are described
herein, we do not guarantee that these are the only hazards which exist.
Page: 4/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-01231
84
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name : AL-1651CS/AL-1661CS/AL-1631/AL-1641CS/AL-1217D/AL-1457D
(Black Toner)
Supplier Identification : Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
2. COMPOSITION / INFORMATION ON INGREDIENTS
Substance[ ] Preparation[X]
Area (Country) (Name and Telephone Number)
North
America
U.S.A. Sharp Electronics Corporation
Sharp Plaza, Mahwah, NJ
Telephone number for information : 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number : 1-800-255-3924
Oceania
Australia Sharp Corporation of Australia PTY. Ltd.
No1 Huntingwood Drive Huntingwood Blacktown N.S.W.
Telephone number for information : 1300-13-50-22
Europe
Germany Sharp Electronics (Europe) GMBH
Sonninstrasse 3, 20097 Hamburg
Telephone number to access MSDS : 040-2376-2185
For more information : 040-2376-2613
United
Kingdom
Sharp Electronics (U. K.) Ltd.
Telephone number for information : 08705-274-277
France Sharp Electronics France S.A.
Telephone number for information : 01-49-90-34-00
Austria Sharp Electronics GMBH
Telephone number for information : 01-727-19-0
Italy Sharp Electronics (Italia) S.P.A.
Telephone number for information : 02895951
Spain Sharp Electronics Espana S.A.
Telephone number for information : 93-581-97-00
Netherlands Sharp Electronics Benelux B.V.
Telephone number for information : 30-6359500
Sweden Sharp Electronics (Nordic) AB
Telephone number for information : 08-634-36-00
Switzerland Sharp Electronics(Schweiz)AG
Telephone number for information : 01-846-6111
Middle
East
U.A.E Sharp Middle East FZE
P.O.Box 17115 Jebel Ali, Dubai
Telephone number for information : 04-815311
Ingredient CAS No. Proportion OSHA PEL ACGIH TLV MAK-TWA NOHSC-TWA
Styrene-Acrylate
copolymer
Confidential 85-90% Not listed Not listed Not listed Not listed
Carbon black 1333-86-4 5-8% 3.5mg/m
3
3.5mg/m
3
Not listed 3mg/m
3
Iron oxide 1317-61-9 1-5% Not listed Not listed Not listed Not listed
Paraffin 8002-74-2 1-3% Not listed Not listed Not listed Not listed
Polypropylene Confidential 0.5-3% Not listed Not listed Not listed Not listed
Page: 1/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-01231
85
3. HAZARDS IDENTIFICATION
Most Important Hazards and Effects of the Products
Human Health Effects : There are no anticipated carcinogenic effects from exposure based on
animal tests performed using toner. When used as intended according to
instructions, studies do not indicate any symptoms of fibrosis will occur.
Environmental Effects : No data are available.
Specific Hazards :Dust explosion (like most finely divided organic powders)
Directive 1999/45/EC(Europe) :Not classified as dangerous
4. FIRST-AID MEASURES
Route(s) of Entry :Inhalation? Skin? Ingestion?
Yes No Possible but very unusual.
Inhalation : Remove to fresh air. If symptoms occur, consult medical personnel.
Skin Contact : Wash with soap and water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact : Flush eyes immediately with water for 15 minutes. If irritation does occur,
consult medical personnel.
Ingestion : Rinse with water and drink several glasses of water. If irritation or discomfort
does occur, consult medical personnel.
5. FIRE -FIGHTING MEASURES
Extinguishing Media : Water, CO
2
, foam and dry chemicals
Special Fire Fighting Procedures:None
Fire and Explosion Hazards : Toner material, like most finely divided organic powders,
may form an explosive mixture.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions :None
Environmental Precautions :None
Methods for Cleaning Up :Wipe off with paper or cloth. Do not use vacuum cleaner when a
large amount is released. It, like most finely divided organic
powders, is capable of creating a dust explosion.
7. HANDLING AND STORAGE
Handling
Technical Measures :None
Precautions :None
Safe Handling Advice :Use of a dust mask is recommended when handling a large quantity of
toner or during long term exposure, as with any non-toxic dust. Try not
to disperse the particles.
Storage
Technical Measures :None
Storage Conditions :Keep container closed and Store in a cool and dry place.
Keep out of the reach of children.
Incompatible Products:None
Page: 2/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-01231
86
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering Measures
Ventilation :Not required under intended use.
Exposure Limit Values
OSHA-PEL (USA) :15mg/m
3
(Total Dust),5mg/m
3
(Respirable Dust)
ACGIH-TLV (USA) :10mg/m
3
(Total Dust),3mg/m
3
(Respirable Dust)
Personal Protective Equipment
Respiratory Protection :Not required under intended use.
Hand Protection :Not required under intended use.
Eye Protection :Not required under intended use.
Skin Protection :Not required under intended use.
Other Protective Equipment :Use of a dust mask and goggles are recommended when
handling a large quantity of toner or during long term exposure,
as with any non-toxic dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State : Solid Form: Powder Color: Black Odor: odorless
Ph :Not applicable
Boiling / Melting Point :Not applicable
Softening Point (C) :130C
Flash Point (C ) :Not applicable
Ignition Point (C ) :No data
Explosion Properties :No data
Density (g/cm
3
) :1.1
Solubility in Water :Negligible
10. STABILITY AND REACTIVITY
Stability : Stable
Hazardous Reactions : Dust explosion, like most finely divided organic powders.
Conditions to Avoid : Electric discharge, throwing into fire.
Materials to Avoid : Oxidizing Materials
Hazardous Decomposition Products: CO, CO
2
and NO
X
Further Information : None
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion (oral) : LD
50
> 2000mg/kg (Rats)
Inhalation : LC
50
>5.14mg/L (Rats)
Eye irritation : Not an irritant (Rabbits)
Skin irritation : Not an irritant (Rabbits)
Skin sensitizer : No data
Mutagenicity : Negative (Ames Test).
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen
(possible human carcinogen). This classification is given to chemicals for
which there is inadequate human evidence, but sufficient animal evidence
on which to base an opinion of carcinogenicity. The classification is based
upon the development of lung tumors in rats receiving chronic inhalation
exposures to free carbon black at levels that induce particle overload of the
lung. Studies performed in animal models other than rats did not show any
association between carbon black and lung tumors. Moreover, a two-year
cancer bioassay using a typical toner preparation containing carbon black
demonstrated no association between toner exposure and tumor
development in rats.
Page: 3/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-01231
87
Chronic Effect : In a study in rats of chronic inhalation exposure to a typical toner, a mild to
moderate degree of lung fibrosis was observed in 92% of the rats in the high
concentration (16mg/m
3
) exposure group, and a minimal to mild degree of
fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
)
exposure group, the most relevant level to potential human exposures.
12. ECOLOGICAL INFORMATION
No data are available.
13. DISPOSAL CONSIDERATIONS
Waste from Residues :Waste material may be dumped or incinerated under conditions
which meet all federal, state and local environmental regulations.
Contaminated Packaging:Waste may be disposed or incinerated under conditions which meet
all federal, state and local environmental regulations.
14. TRANSPORT INFORMATION
UN Classification :None
Not classified as hazardous for transport.
15. REGULATORY INFORMATION
US Information
TSCA (Toxic Substances Control Act) :
All chemical substances in this product comply with all applicable rules or order under TSCA.
SARA (Superfund Amendments and Reauthorization Act) Title III
302 Extreme Hazardous Substance :None
311/312 Hazard Classification :None
EU Information
1999/45/EC and 67/548/EEC
Symbol & Indication :Not required
R-Phrase :Not required
76/769/EEC :All chemical substances in this product comply with all
applicable rules or order under 76/769/EEC.
16. OTHER INFORMATION
NFPA Rating (USA) :Health=1 Flammability=1 Reactivity=0
WHMIS Legislation (Canada) :This product is not a controlled product.
References
IARC (1996) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process And Printing Inks, Carbon Black and Some
Nitro Compounds, Lyon, pp.149-261 H.Muhle, B.Bellmann, O.Creutzenberg,
C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie, P.Morrow, U.Mohr,
S.Takenaka, and R.Mermelstein(1991) Pulmonary Response to Toner upon
Chronic Inhalation Exposure in Rats. Fundamental and Applied Toxicology 17,
pp.280-299.
The information on this data sheet represents our current data and best opinion as to the proper
use in handling of this product under normal conditions. However, all materials may present
unknown hazards and should be used with caution. Although certain hazards are described
herein, we do not guarantee that these are the only hazards which exist.
Page: 4/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-31231
88
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name : AL-1651CS/AL-1661CS/AL-1631/AL-1641CS/AL-1217D/AL-1457D
(Black Developer)
Supplier Identification : Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
2. COMPOSITION / INFORMATION ON INGREDIENTS
Substance[ ] Preparation[X]
Area (Country) (Name and Telephone Number)
North
America
U.S.A. Sharp Electronics Corporation
Sharp Plaza, Mahwah, NJ
Telephone number for information : 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number : 1-800-255-3924
Oceania
Australia Sharp Corporation of Australia PTY. Ltd.
No1 Huntingwood Drive Huntingwood Blacktown N.S.W.
Telephone number for information : 1300-13-50-22
Europe
Germany Sharp Electronics (Europe) GMBH
Sonninstrasse 3, 20097 Hamburg
Telephone number to access MSDS : 040-2376-2185
For more information : 040-2376-2613
United
Kingdom
Sharp Electronics (U. K.) Ltd.
Telephone number for information : 08705-274-277
France Sharp Electronics France S.A.
Telephone number for information : 01-49-90-34-00
Austria Sharp Electronics GMBH
Telephone number for information : 01-727-19-0
Italy Sharp Electronics (Italia) S.P.A.
Telephone number for information : 02895951
Spain Sharp Electronics Espana S.A.
Telephone number for information : 93-581-97-00
Netherlands Sharp Electronics Benelux B.V.
Telephone number for information : 30-6359500
Sweden Sharp Electronics (Nordic) AB
Telephone number for information : 08-634-36-00
Switzerland Sharp Electronics(Schweiz)AG
Telephone number for information : 01-846-6111
Middle
East
U.A.E Sharp Middle East FZE
P.O.Box 17115 Jebel Ali, Dubai
Telephone number for information : 04-815311
Ingredient CAS No. Proportion OSHA PEL ACGIH TLV MAK-TWA NOHSC-TWA
Iron powder 7439-89-6 90-95% Not listed Not listed Not listed Not listed
Styrene-Acrylate
copolymer
Confidential 5-10% Not listed Not listed Not listed Not listed
Carbon black 1333-86-4 0.1-0.9% 3.5mg/m
3
3.5mg/m
3
Not listed 3mg/m
3
Page: 1/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-31231
89
3. HAZARDS IDENTIFICATION
Most Important Hazards and Effects of the Products
Human Health Effects : There are no anticipated carcinogenic effects from exposure based on
animal tests performed using toner. When used as intended according to
instructions, studies do not indicate any symptoms of fibrosis will occur.
Environmental Effects : No data are available.
Specific Hazards :Dust explosion (like most finely divided organic powders)
Directive 1999/45/EC(Europe) :Not classified as dangerous
4. FIRST-AID MEASURES
Route(s) of Entry :Inhalation? Skin? Ingestion?
No No Possible but very unusual.
Inhalation : Remove to fresh air. If symptoms occur, consult medical personnel.
Skin Contact : Wash with soap and water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact : Flush eyes immediately with water for 15 minutes. If irritation does occur,
consult medical personnel.
Ingestion : Rinse with water and drink several glasses of water . If irritation or discomfort
does occur, consult medical personnel.
5. FIRE -FIGHTING MEASURES
Extinguishing Media : Water, CO
2
, foam and dry chemicals
Special Fire Fighting Procedures:None
Fire and Explosion Hazards : Toner material, like most finely divided organic powders,
may form an explosive mixture.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions :None
Environmental Precautions :None
Methods for Cleaning Up :Wipe off with paper or cloth. Do not use vacuum cleaner when a
large amount is released. It, like most finely divided organic
powders, is capable of creating a dust explosion.
7. HANDLING AND STORAGE
Handling
Technical Measures :None
Precautions :None
Safe Handling Advice :Use of a dust mask is recommended when handling a large quantity of
toner or during long term exposure, as with any non-toxic dust. Try not
to disperse the particles.
Storage
Technical Measures :None
Storage Conditions :Keep container closed and Store in a cool and dry place.
Keep out of the reach of children.
Incompatible Products:None
Page: 2/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-31231
90
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering Measures
Ventilation :Not required under intended use.
Exposure Limit Values
OSHA-PEL (USA) :15mg/m
3
(Total Dust) , 5mg/m
3
(Respirable Dust)
ACGIH-TLV (USA) :10mg/m
3
(Total Dust) , 3mg/m
3
(Respirable Dust)
Personal Protective Equipment
Respiratory Protection :Not required under intended use.
Hand Protection :Not required under intended use.
Eye Protection :Not required under intended use.
Skin Protection :Not required under intended use.
Other Protective Equipment :Use of a dust mask and goggles are recommended when
handling a large quantity of toner or during long term exposure,
as with any non-toxic dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State : Solid Form: Powder Color: Black Odor: odorless
Ph :Not applicable
Boiling / Melting Point :Not applicable
Softening Point(C ) :130C(toner)
Flash Point (C ) :Not applicable
Ignition Point(C ) :No data
Explosion Properties :No data
Density (g/cm
3
) :7
Solubility in Water :Negligible
10. STABILITY AND REACTIVITY
Stability : Stable
Hazardous Reactions : Dust explosion, like most finely divided organic powders.
Conditions to Avoid : Electric discharge, throwing into fire.
Materials to Avoid : Oxidizing Materials
Hazardous Decomposition Products: CO, CO
2
and NO
X
Further Information : None
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion (oral) : LD
50
> 2000mg/kg (Rats)
Inhalation : LC
50
>5.14mg/L (Rats)
Eye irritation : Not an irritant (Rabbits)
Skin irritation : Not an irritant (Rabbits)
Skin sensitizer : No data
Mutagenicity : Negative (Ames Test).
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen
(possible human carcinogen). This classification is given to chemicals for
which there is inadequate human evidence, but sufficient animal evidence
on which to base an opinion of carcinogenicity. The classification is based
upon the development of lung tumors in rats receiving chronic inhalation
exposures to free carbon black at levels that induce particle overload of the
lung. Studies performed in animal models other than rats did not show any
association between carbon black and lung tumors. Moreover, a two-year
cancer bioassay using a typical toner preparation containing carbon black
demonstrated no association between toner exposure and tumor
development in rats.
Page: 3/4
MATERIAL SAFETY DATA SHEET
Date Issued : Sep . 1, 2003
MSDS No. F-31231
91
Chronic Effect : In a study in rats of chronic inhalation exposure to a typical toner, a mild to
moderate degree of lung fibrosis was observed in 92% of the rats in the high
concentration (16mg/m
3
) exposure group, and a minimal to mild degree of
fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
)
exposure group, the most relevant level to potential human exposures.
12. ECOLOGICAL INFORMATION
No data are available.
13. DISPOSAL CONSIDERATIONS
Waste from Residues :Waste material may be dumped or incinerated under conditions
which meet all federal, state and local environmental regulations.
Contaminated Packaging:Waste may be disposed or incinerated under conditions which meet
all federal, state and local environmental regulations.
14. TRANSPORT INFORMATION
UN Classification :None
Not classified as hazardous for transport.
15. REGULATORY INFORMATION
US Information
TSCA (Toxic Substances Control Act) :
All chemical substances in this product comply with all applicable rules or order under TSCA.
SARA (Superfund Amendments and Reauthorization Act) Title III
302 Extreme Hazardous Substance :None
311/312 Hazard Classification :None
EU Information
1999/45/EC and 67/548/EEC
Symbol & Indication :Not required
R-Phrase :Not required
76/769/EEC :All chemical substances in this product comply with all
applicable rules or order under 76/769/EEC.
16. OTHER INFORMATION
NFPA Rating (USA) :Health=1 Flammability=1 Reactivity=0
WHMIS Legislation (Canada) :This product is not a controlled product.
References
IARC (1996) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process And Printing Inks, Carbon Black and Some
Nitro Compounds, Lyon, pp.149-261 H.Muhle, B.Bellmann, O.Creutzenberg,
C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie, P.Morrow, U.Mohr,
S.Takenaka, and R.Mermelstein(1991) Pulmonary Response to Toner upon
Chronic Inhalation Exposure in Rats. Fundamental and Applied Toxicology 17,
pp.280-299.
The information on this data sheet represents our current data and best opinion as to the proper
use in handling of this product under normal conditions. However, all materials may present
unknown hazards and should be used with caution. Although certain hazards are described
herein, we do not guarantee that these are the only hazards which exist.
Page: 4/4
92
INDEX
A
Acrobat Reader ................................. 43
Alarm indicator
- Drum replacement required
indicator.............................. 6, 58, 62
- Misfeed indicator ................ 6, 62, 63
- TD cartridge replacement required
indicator.............................. 6, 57, 62
Appendix ........................................... 68
Auto clear time ............................ 54, 55
Auto power shut-off mode ........... 54, 55
Automatic exposure adjustment ........ 50
B
Before installation.............................. 20
Button Manager ........................... 19, 34
Bypass feed....................................... 17
Bypass tray paper guides.............. 5, 18
C
Cautions
- Handling ......................................... 2
- Label............................................... 1
- Using .............................................. 1
Charger cleaner............................. 5, 60
Checking packed components and
accessories ......................................... 8
Cleaning the unit
- Cabinet ......................................... 59
- Document glass............................ 59
- SPF .............................................. 59
- SPF scanning window.................. 59
- Transfer charger........................... 60
Clear key ................................. 6, 49, 56
Connecting the interface cable
- Parallel interface cable................. 45
- USB interface cable...................... 45
Conventions used in this manual and
online manual ...................................... 4
Copy flow........................................... 46
Copy quantity .................................... 49
Copy quantity key.................... 6, 49, 55
Copy ratio display key ................... 6, 51
Copy ratio selector indicator .......... 6, 51
Copy ratio selector key.................. 6, 51
D
Dark key ........................................ 6, 49
Display................................................. 6
Displaying total number of copies ..... 56
Disposing of TD cartridge.................. 57
Document glass............................. 5, 47
Drum cartridge............................... 5, 58
Drum cartridge replacement ............. 58
Drum replacement required
indicator................................... 6, 58, 62
E
Exposure adjustment......................... 49
Exposure mode indicator............... 6, 49
Exposure mode selector key......... 6, 49
F
Flow of installation............................. 21
Front cover .......................................... 5
Fusing unit release lever ............... 5, 65
H
Handle................................................. 5
Hardware and software
requirements ..................................... 20
How to print ....................................... 33
How to use the online manual ........... 43
I
Indicators on the operation panel ...... 31
Initial settings of operation panel ....... 13
Installing the software.................. 19, 21
Installing the TD cartridge ................. 10
Interface
- Parallel interface........................... 45
- USB interface ............................... 45
Interface cable................................... 70
Interrupt copying................................ 47
Introduction.......................................... 4
L
Light and dark indicator ................. 6, 49
Light key........................................ 6, 49
Loading paper ................................... 14
Loading the paper tray ...................... 15
93
M
Making copies ................................... 46
MFP driver
- Print Status Window..................... 19
- Printer driver................................. 19
- Scanner driver .............................. 19
Misfeed indicator ..................... 6, 62, 63
Misfeed removal
- Fusing area .................................. 65
- Paper feed area............................ 64
- SPF .............................................. 67
- Transport area.............................. 66
Moving instructions............................ 71
Multi-bypass tray ............................... 17
N
Name
- Operation panel.............................. 6
- Part names..................................... 5
O
ONLINE indicator .......................... 6, 31
ONLINE key .................................. 6, 31
Online manual ............................... 4, 43
Opening the printer driver.................. 32
Opening the scanner driver ............... 40
Operation panel ............................... 5, 6
Original placement
- Document glass............................ 47
- SPF .............................................. 48
Original to copy key....................... 6, 53
P
Paper ................................................. 14
Paper feed location indicator ......... 6, 51
Paper output tray................................. 5
Paper output tray extension .......... 5, 46
Paper tray...................................... 5, 15
Parallel interface cable................ 45, 70
Photo copying.................................... 49
Power cord .......................................... 5
Power off ........................................... 13
Power on ........................................... 12
Power save indicator ..................... 6, 31
Power switch ................................. 5, 12
Preheat mode.................................... 55
Preparing the unit for installation......... 8
Printer driver ...................................... 19
Proper storage................................... 71
R
Reduction/enlargement/zoom........... 51
S
Scan head locking switch.................... 9
Scanner driver ................................... 19
SCANNER indicator ...................... 6, 31
SCANNER key .............................. 6, 39
Scanning from your computer ........... 40
Scanning with the "Scanner
and Camera Wizard" ......................... 42
Setting up the unit ............................... 7
Setup procedure.................................. 7
Sharpdesk ......................................... 19
Side cover ........................................... 5
Side cover open button ....................... 5
Software for the SHARP Personal MFP
series................................................. 19
Specifications .................................... 68
SPF ............................................... 5, 48
SPF indicator................................. 6, 48
SPF misfeed indicator ................... 6, 67
Start indicator ................................ 6, 31
Start key .................................. 6, 46, 56
Status indicators................................ 62
Stream feeding mode............ 48, 54, 55
Supplies and options......................... 70
Supply list
- Drum cartridge.............................. 70
- TD cartridge.................................. 70
T
TD cartridge............................. 5, 10, 57
TD cartridge replacement.................. 57
TD cartridge replacement required
indicator................................... 6, 57, 62
Transfer charger............................ 5, 60
Tray select key .............................. 6, 51
Troubleshooting................................. 61
Troubleshooting the unit ................... 61
94
U
USB interface cable..................... 45, 70
Using other installed drivers .............. 44
Using the manuals............................... 4
Using the printer mode...................... 32
Using the scanner mode ................... 34
Using the SHARP TWAIN ................. 40
Z
ZOOM indicator ............................. 6, 51
ZOOM key..................................... 6, 51
INDEX BY PURPOSE
Checking the package......................... 8
Cleaning the unit
- Cabinet ......................................... 59
- Document glass............................ 59
- SPF .............................................. 59
- Transfer changer .......................... 60
Connecting the interface cable
- Parallel interface cable................. 45
- USB interface cable...................... 45
Copying ............................................. 46
Displaying total number of copies...... 56
Enlarging/reducing copies ................. 51
Installing the software
- Acrobat ......................................... 43
- Button Manager............................ 19
- MFP driver.................................... 19
- Sharpdesk .................................... 19
Installing the TD cartridge ................. 10
Loading paper
- Multi-bypass tray .......................... 17
- Paper tray..................................... 15
Loading the original
- Document glass............................ 47
- SPF .............................................. 48
Moving the unit .................................. 71
Opening the printer driver.................. 32
Power off ........................................... 13
Power on ........................................... 12
Preparing for installation...................... 8
Printing .............................................. 33
Removing paper jams
- Fusing area .................................. 65
- Paper feed area............................ 64
- SPF .............................................. 67
- Transport area.............................. 66
Replacing the drum cartridge ............ 58
Replacing the TD cartridge................ 57
Scanning
- Button Manager............................ 34
- Scanner and Camera Wizard....... 42
- SHARP TWAIN ............................ 40
Selecting the tray............................... 51
Setting the copy quality
- AUTO........................................... 50
- MANUAL ...................................... 49
- PHOTO......................................... 49
Setting the copy quantity................... 49
Setting the toner save mode ............. 54
Setting the user program................... 55
Setting up the Button Manager.......... 34
Storing the unit .................................. 71
Two-sided copying ............................ 52
Using other installed drivers.............. 44
Using the online manual .................... 43
95
MEMO
96
MEMO
For users in the USA
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
WARNING:
FCC Regulations state that any unauthorized changes or modifications to this
equipment not expressly approved by the manufacturer could void the users
authority to operate this equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
G
G
G
G
mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
Shielded cables must be used with this equipment to maintain compliance with
standards.
Notice for Users in U.S.A.
Installed Printer Board (For Printer Standard Model)
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Model Number: AL- 12PK (Printer/Scanner Expansion Kit)
Responsible Party: SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-1163
TEL: 1-800-BE-SHARP
AL-12PK
Tested To Comply
With FCC Standards
FOR HOME OR OFFICE USE
This product utilizes tin-lead solder, and a fluorescent lamp containing a small
amount of mercury.
Disposal of these materials may be regulated due to environmental
considerations.
For disposal or recycling information, please contact your local authorities or
the Electronics Industries Alliance: www.eia.org
PRINTED IN CHINA
KS
TINSE1161QSZZ
2003J
Printed on 100% post-consumer recycled paper
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-1163.
www.sharpusa.com
SHARP ELECTRONICS OF CANADA LTD.
335 Britannia Road East, Mississauga, Ontario, L4Z 1W9
SHARP CORPORATION
1