Double Pipe Heat Exchanger Design: Chemical Engineering Spreadsheets

This document provides design specifications for a double pipe heat exchanger. It lists materials, dimensions, fluid properties and flow rates, as well as results from heat transfer calculations including mean temperature, heat transfer coefficient, LMTD, pressure drop and selected pipe dimensions. The heat exchanger is a counter-current design used to preheat a feed stream using two carbon steel pipes.

Uploaded by

rudy_423522658
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
690 views2 pages

Double Pipe Heat Exchanger Design: Chemical Engineering Spreadsheets

This document provides design specifications for a double pipe heat exchanger. It lists materials, dimensions, fluid properties and flow rates, as well as results from heat transfer calculations including mean temperature, heat transfer coefficient, LMTD, pressure drop and selected pipe dimensions. The heat exchanger is a counter-current design used to preheat a feed stream using two carbon steel pipes.

Uploaded by

rudy_423522658
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

DOUBLE PIPE HEAT EXCHANGER DESIGN

ChemSOF.com
Chemical Engineering Spreadsheets Tag No. Name Date By Outer Pipe Carbon Steel Counter-current 20 Outer Pipe Inside Diameter DP-101 Feed Preheater 07 October 2013 ChemSOF

Double Pipe Data Hot Fluid Location Material Hairpin Length Inner Pipe Inside Diameter Outside Diameter Fluid Data Flowrate Inlet Temperature Outlet Temperature Fouling Factor ft

2.067 inch 2.375 inch Hot 9692.31 150.0 130.0 0.001

3.068 inch

lb/h F F h.ft.F/BTU

Cold 10000.0 60.0 84.0 0.001

Properties @ Mean Temperature lb/ft Density Viscosity cP BTU/lb.F Specific Heat BTU/ft.h.F Thermal Conductivity Viscosity at Wall cP Calculations Mean Temperature Equivalent Diameter Velocity Prandtl's Number Reynold's Number Flow Region Correlation Film Coefficient Straight Length DP Total Pressure Drop (Including Bends) Sizing Result LMTD Tube wall temperature Heat Transfer Coefficient Area Length No. of Hairpin Hairpin Selected

48.4 2 0.52 0.1 2 Hot 140.0 0.693 2.70 25.16 5623 Transient Gnienlinski 123.74 1.318 1.364

47.5 0.55 0.42 0.092 0.55 Cold 72.0 2.067 2.51 6.07 55557 Turbulent Gnienlinski 184.56 0.220 0.259

F inch ft/s Pr Re

BTU/h.ft.F psi psi

F F BTU/h.ft.F ft ft

67.98 101.59 58.88 25.19 40.51 1.01 1.00

DOUBLE PIPE HEAT EXCHANGER DESIGN


ChemSOF.com
Chemical Engineering Spreadsheets Tag No. Name Date By Outer Pipe Carbon Steel Counter-current 6.096 Outer Pipe Inside Diameter DP-101 Feed Preheater 07 October 2013 ChemSOF

Double Pipe Data Hot Fluid Location Material Hairpin Length Inner Pipe Inside Diameter Outside Diameter Fluid Data Flowrate Inlet Temperature Outlet Temperature Fouling Factor m

52.5 mm 60.3 mm Hot 4396.4 65.6 54.4 0.00020

77.93 mm

kg/h C C h.m.C/kcal

Cold 4535.9 15.6 28.9 0.00020

Properties @ Mean Temperature kg/m Density Viscosity cP kcal/kg.C Specific Heat kcal/m.h.C Thermal Conductivity Viscosity at Wall cP Calculations Mean Temperature Equivalent Diameter Velocity Prandtl's Number Reynold's Number Flow Region Correlation Film Coefficient Straight Length DP Total Pressure Drop (Including Bends) Sizing Result LMTD Tube wall temperature Heat Transfer Coefficient Area Length No. of Hairpin Hairpin Selected

775.29 2 0.52 0.15 2 Hot

760.88 0.55 0.42 0.14 0.55 Cold 22.2 52.5 0.76 6.07 55557 Turbulent Gnienlinski 901.08 0.015 0.018

C mm m/s Pr Re

kcal/h.m.C bar bar

60.0 17.6 0.82 25.16 5623 Transient Gnienlinski 604.15 0.091 0.094

C C kcal/h.m.C m m

37.77 38.66 287.46 2.34 12.35 1.01 1.00