This document provides information about connecting a GP device to Fuji Electric PLCs. It includes cable diagrams and lists supported PLC models and their readable and writable device ranges. System area addresses that can be used with different device types are also discussed.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
620 views13 pages
Fuji PLC Conection 1
This document provides information about connecting a GP device to Fuji Electric PLCs. It includes cable diagrams and lists supported PLC models and their readable and writable device ranges. System area addresses that can be used with different device types are also discussed.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13
Device/PLC Connection
About the Device/PLC Connection Manuals
Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection manual" information. Also, be sure to download the "Preface for Trademark Rights, List of Units Supported, How to Read Manuals and Documentation Conventions" PDF file. Furthermore, be sure to keep all manual-related data in a safe, easy-to-find location. Manuals Chapter 2 - PLC-GP Connection 2-3-1 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual CPU LinkI/F CableDiagram Cables GP PC I/F Module/ Generic I/F F80H, F120H, F250 FFU-120B PC Interface Module RS-232C (Cable Diagram 1) RS-422 (Cable Diagram 2) RS-232C Digital's GP410-IS00-O (5m) F70S (NC1P-S0) NC1L-RS2 (Generic Interface) *1 RS-232C (Cable Diagram 1) Digital's GP410-IS00-O (5m) GP Series 2.3 Fuji Electric 2.3.1 System Structure Ref er ence The following describes the system structure for connecting the GP to Fuji Electric Corporation, Ltd. PLCs. Cable Diagrams mentioned in the following tables are listed in the section titled "2.3.2 Cable Diagrams". In the LS area, 32-bit devices are not supported. Therefore, when System Area addresses are allocated to BD, DL, or W33 devices, only System Area (LS0 to LS19) addresses can be used. Other LS areas, such as the user area, etc. should not be used. MICREX-F Series (using Link I/F) ! !! !! Important *1 When expansion units are attached via a T-Link system to a main PLC unit, and more than 2 link units are attached to the expansion unit, the GP unit can be attached to only one of the link units. (Simultaneous connection to 2 link units is not possible.) Simultaneous connection to 2 link units is possible only when they are at- tached to the main PLC unit. Chapter 2 - PLC-GP Connection 2-3-2 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual CPU LinkI/F CableDiagram Cables GP General SIO Unit/ General I/F Module NB1, NB2, NB3 NB-RS1-AC (Generic RS-232C/ 485 SIO unit) RS-232C (Cable Diagram 1) RS-422 (Cable Diagram 2) RS-232C Digital's GP410-IS00-O (5m) NJ-RS2 (Generic RS- 232C SIO interface module) RS-232C (Cable Diagram 1) Digital's GP410-IS00-O (5m) NJ-RS2 (Generic RS- 485 SIO interface module) RS-422 (Cable Diagram 2) NS NS-RS1 (Generic RS- 232C/485 interface module) RS-232C (Cable Diagram 1) RS-422 (Cable Diagram 2) RS-232C Digital's GP410-IS00-O (5m) NJ GP Series CPU Adapter CableDiagram Cables GP PC Loader adapter F80H, F250, F120H Fuji Electric's FLT-ASFK RS-232C (Cable Diagram 1) RS-232C Digital's GP410-IS00-O GP Series Note: Note: Note: Note: Note: Places noted as RS-422 can also use RS-485 on the PLC side. MICREX-F Series (FLT-ASFK) (CPU Direct Connection) FLEX-PC Series (using Link I/F) CPU LinkI/F CableDiagram Cables GP PC Interface Module FFK120A-C10 RS-232C (Cable Diagram 1) RS-422 (Cable Diagram 2) RS-232C Digital's GP410-IS00-O (5m) FFK100A-C10 RS-232C (Cable Diagram 3) GP Series F80H, F120H, F250 F30, F50, F60, F80, F81, F120 F120S, F200 MICREX-F Series <T-link> (using Link I/F) Chapter 2 - PLC-GP Connection 2-3-3 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual CPU CableDiagram GP NB1, NB2, NB3, NJ, NS RS-422 (Cable Diagram 4) GP Series FLEX-PC Series (CPU Direct Connection) When using Digital's T-Link I/F Unit, refer to the GP-*50/70 Series T-Link I/F Unit User's Manual. Note: Note: Note: Note: Note: Chapter 2 - PLC-GP Connection 2-3-4 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual 2.3.2 Cable Diagrams ! !! !! Important Careful! Careful! The cable diagrams illustrated below and the cable diagrams recommended by Fuji Electric Co., Ltd. may differ; in any case, using these cables for your PLC operations will not cause any problems. Ground your PLC's FG terminal according to your country's appli- cable standard. For details, refer to the corresponding PLC manual. Connect the FG line of the Shield cable to either the GP or PLC, depending on your environment. When using a connector hood and grounding the FG line, be sure to use an electrical conduc- tor. For the RS-232C connection, use a cable length less than 15m. If a communications cable is used, it must be connected to the SG (signal ground). Cable Diagram 1 (RS-232C) When using Digital's RS-422 connector terminal adapter GP070-CN10-0 Turn on the Termination Resistor switch, on the PLC side. Cable Diagram 2 (RS-422) NC Chapter 2 - PLC-GP Connection 2-3-5 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual Note: Note: Note: Note: Note: When using Digital's RS-422 Cable, GP230-IS11-0 When making your own cable connections When making your own cable connections, we recommend using Hitachi Densen's CO-SPEV-SB(A)3P*0.5S cable. When connecting the #9 and #10 pins in the GP Serial I/F, a termination resis- tance of 100 is added between RDA and RDB. Cable Diagram 3 (RS-232C) A4 ER A6 CI B1 FG B2 SD B3 RD B4 RS B5 CS B6 DR B7 SG B8 CD PLC RDA RDB SDA SDB SDA SDB RDA RDB S NC CD Chapter 2 - PLC-GP Connection 2-3-6 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual Note: Note: Note: Note: Note: Cable Diagram 4 (RS-422) For the PLC side connector (modular-jack) you can use Hirose's TM11P-88P. The pin numbers of the modular-jack for the connec- tion diagrams below are based on the order described in the figure at the left. When using Digital's RS-422 connector terminal adapter GP070-CN10-0 When using Digital's RS-422 Cable, GP230-IS11-0 When making your own cable connections When connecting the #9 and #10 pins in the GP Serial I/F, a termination resis- tance of 100 is added between RDA and RDB. Note: Note: Note: Note: Note: Chapter 2 - PLC-GP Connection 2-3-7 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual 2.3.3 Supported Devices Setup System Area here. (See next page) The following describes the range of devices supported by the GP. MICREX-F Series * 1 The MSB (most significant bit) of a word device corresponds to bit 0 of the device, and the LSB (least significant bit) corresponds to bit F. E.g. When hexadecimal data 0001 is written to a Word device address Device Bit Address Word Address I/O Relay B0000 ~ B511F WB0000 ~ WB0511 *1 Direct I/O --- W24.0000 ~ W24.0159 Auxilary Relay M0000 ~ M511F WM0000 ~ WM0511 *1 Keep Relay K0000 ~ K063F WK000 ~ WK063 *1 Differential Relay D0000 ~ D063F WD000 ~ WD063 *1 *4 Link Relay L0000 ~ L511F WL000 ~ WL0511 *1 Special Relay F00000 ~ F4095F WF0000 ~ WF4095 *1 *4 Announce Relay A00000 ~ A4095F WA0000 ~ WA4095 *1 *4 Timer 0.01 sec T0000 ~ T0511 --- Timer 0.1 sec T0512 ~ T1023 --- Counter C0000 ~ C0255 --- Timer 0.01 sec (current value) --- TR0000 ~ TR0511 Timer 0.01 sec (setup value) --- TS0000 ~ TS0511 Timer 0.1 sec (current value) --- W9.000 ~ W9.511 Counter (current value) --- CR0000 ~ CR0255 Counter (setup value) --- CS0000 ~ CS0255 --- BD0000 ~ BD4095 --- DI0000 ~ DI4095 --- SI0000 ~ SI4095 --- W30.0000 ~ W30.4094 *2 --- W31.0000 ~ W31.4094 *2 --- W32.0000 ~ W32.4094 *2 --- W33.0000 ~ W33.4094 *3 --- W34.0000 ~ W34.4094 *3 Particulars Data Memory File Memory H/L Chapter 2 - PLC-GP Connection 2-3-8 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual * 2 Define and use 16 bit length data. * 3 Define and use 32 bit length data. * 4 This device cannot write. Use it only for reading. ! !! !! Important In the LS area, 32-bit devices are not supported. Therefore, when System Area addresses are allocated to BD, DL, or W33 devices, only System Area (LS0 to LS19) addresses can be used. Other LS areas, such as the user area, etc. should not be used. When using the GP-570VM or GP-870VM, do not allocate the Sys- tem Area for BD, DI, or W33 word addresses. Certain PLC models and versions may not be able to perform bit reading or writing. F30.......... not possible with versions 0.9 or lower F50.......... not possible with versions 1.4 or lower F50H ....... not possible with versions 0.7 or lower F80.......... not possible with any version F81.......... not possible with any version F120........ not possible with any version F200........ not possible with any version Check the information plate on the side of the PLC to find the PLCs version information. When processing 16-bit single word data: Internally, the GP basically processes 1 word as 16 bit length data. As a result, the reading and writing of 32 bit length data devices are processed as follows: Reading From 32 bit data, reads data only from the bottom 16 bits. Writing From 32 bit data, writes data only to the bottom 16 bits, as 0 is written to the top 16 bits. E.g. When data is 12345678 hex. When processing 2 word 32-bit data: Two word addresses at bit length 16 are necessary to handle 32 bit long data, but when using a 32 bit device, only one word address needs to be specified. (from previous page) Chapter 2 - PLC-GP Connection 2-3-9 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual Setup System Area here. When using a 16 bit device When using a 32 bit device FLEX-PC Series Cannot read the Timer and Counter setup value. However, the write opera- tion is possible only when the PLC is in program mode. * 1 Define and use 16 bit length data. Note: Note: Note: Note: Note: Device Bit Address Word Address Input Relay X0000 ~ X07FF WX0000 ~ WX07F Output Relay Y0000 ~ Y07FF WY0000 ~ WY07F Intemal Relay M0000 ~ M03FF WM000 ~ WM03F Extended Intemal Relay M0400 ~ M1FFF WM040 ~ WM1FF Latch Relay L0000 ~ L03FF WL000 ~ WL03F Extended Latch Relay L0400 ~ L1FFF WL040 ~ WL1FF Special Relay M8000 ~ M81 FF WM800 ~ WM81F Timer T0000 ~ T03FF --- Counter C0000 ~ C01FF --- Timer (current value) --- T0000 ~ T03FF Timer (setup value) --- TS0000 ~ TS03FF *1 Counter (current value) --- C0000 ~ C01FF Counter (setup value) --- CS0000 ~ CS01FF *1 Data Register --- D0000 - D2FFF Special Register --- D8000 ~ D837F Link Register --- W0000 ~ W3FFF File Register --- R0000 ~ R7EFF Particulars L/H Chapter 2 - PLC-GP Connection 2-3-10 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual When the Timer and Counter setup values are written from the GP, the ladder is changed so that the setup value uses a relative reference. For this reason, be careful when the setup value for the Timer and Counter uses an indirect ladder. Normally, access is recommended for indirectly referenced devices. 2.3.4 Environment Setup The following tables list Digital's recommended PLC and GP communication settings. MICREX-F Series (using PC I/F module FFU120B) MICREX-F Series (using General Interface Module NC1L-RS2) Baud Rate 19200 bps Baud Rate 19200 bps Data Length 7 bits Data Length 7 bits Stop Bit 2 bits Stop Bit 2 bits Parity Bit Even Parity Bit Even Data Flow Control ER Control Transfer Condition DTR on/ CTS on Communication Format (RS-232C) RS-232C MODE Switch (RS-232C) 1 Communication Format ( RS-422) 4-wire type MODE Switch (RS-422) 3 Char. structure Switch 8 (lNlT) is Off RS-485 Station # setup Switch (Oniy for RS-485) 0 Unit No. 0 (fixed) --- FFU120B Setup --- --- GP Setup Baud Rate 19200 bps Baud Rate 19200 bps Data Length 8 bits Data Bit 8 bits Stop Bit 1 bit Stop Bit 1 bit Parlty Bit None Parity Bit None Data Flow Control ER Control Transfer Condition DTR on/CTS on Communication Format RS-232C MODE Setup 1 Character Structure Switch 8 (Initialize Setup Process) is Off (Initial file) Unit No. 0 (fixed) --- --- GP Setup NC1L-RS2Setup Setup this data in File Definition. Communication is not possible when using a Link I/F switch. Setup this data in File Definition. Communication is not possible when using a Link I/F switch. ! !! !! Important ! !! !! Important Chapter 2 - PLC-GP Connection 2-3-11 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual MICREX-F Series (using PC I/F capsule FFK120A-C10) Baud Rate 19200 bps Baud Rate 19200 bps Data Length 7 bits Data Length 7 bits Stop Bit 2 bits Stop Bit 2 bits Parity Bit Even Parity Bit Even Data Flow Control ER Control Transfer Condition None Communication Format (RS-232C) RS-232C MODE Switch (RS-232C) 1 Communication Format (RS-422) 4-wire type MODE Switch (RS-422) 3 RS-485 Station # setup Switch (Only when using RS-485) 0 Unit No. 0 (fixed) --- --- FFK120A-C10Setup GP Setup Setup this data in File Definition. Communication is not possible when using a Link I/F switch. MICREX-F Series (using PC I/F capsule FFK100A-C10) Setup this data in File Definition. Communication is not possible when using a Link I/F switch. Baud Rate 19200 bps Baud Rate 19200 bps Data Length 7 bits Data Length 7 bits Stop Bit 2 bits Stop Bit 2 bits Parity Bit Even Parity Bit Even Data Flow Control ER Control Communication Format (When using RS-232C) RS-232C Unit No. 0 (fixed) PK access Permitted Code conversion Available --- --- --- FFK100A-C10Setup GP Setup --- ! !! !! Important ! !! !! Important Chapter 2 - PLC-GP Connection 2-3-12 2.3 Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual FLEX-PC Series (using Link I/F) FLEX-PC Series (using CPU Direct Connection) MICREX-F Series (FLT-ASFK) Baud Rate 19200 bps Baud Rate 19200 bps Data Length 8 bits Data Length 8 bits Stop Bit 1 bit Parity Bit None Parity Bit ON/OFF EVEN/ODD OFF None Data Flow Control ER Control Communication Format RS-232C Unit No. 0 MODE LOADER Adapter Setup GP Setup --- --- --- --- --- Baud Rate 19200 bps Baud Rate 19200 bps Data Length 7 bits Data Length 7 bits Stop Bit 1 bit Stop Bit 1 bit Parity Bit Even Parity Bit Even Data Flow Control ER Control Transfer Condition DTR on/ CTS on Communication Format (RS-232C) RS-232C MODE Switch (RS-232C) 1 Communication Format (RS-422) 4-wire type MODE Switch (RS-422) 3 Unit No. 1 Station No. 1 Communication Unit / lnterfaceModuleSetup GP Setup PLC sideSetup Baud Rate 19200 bps(fixed) --- Data Length 8 bits (fixed) --- Stop Bit 1 bit (fixed) --- Parity Bit Odd (fixed) --- Data Flow Control ER Control (fixed) --- Communication Format 4-wire type (fixed) --- Unit No. 1 (fixed) --- GP Setup