0% found this document useful (0 votes)
537 views2 pages

3-Phase Test Separators VVF

Standard well test separator is a three-phase horizontal design that efficiently separates the well effluent into three constituents (gas, oil, and water) separator operating parameters will vary according to the fluid type and flowing conditions for optimized separation. Pressure, temperature, and sampling ports on inlet and outlet lines enable maximum measurement and sampling in all phases.

Uploaded by

PetroFisic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
537 views2 pages

3-Phase Test Separators VVF

Standard well test separator is a three-phase horizontal design that efficiently separates the well effluent into three constituents (gas, oil, and water) separator operating parameters will vary according to the fluid type and flowing conditions for optimized separation. Pressure, temperature, and sampling ports on inlet and outlet lines enable maximum measurement and sampling in all phases.

Uploaded by

PetroFisic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Surface Well Testing

22310 N. Moorefield Rd. Edinburg, TX 78541

Three-Phase Well Test Separator


VVFs standard well test separator is a three-phase horizontal design that efficiently separates the well effluent into three constituents (gas, oil, and water) to enable these processed fluids to be individually measured and directed for collection, burning/flaring, or controlled disposal, depending on the application. Separator operating parameters will vary according to the fluid type and flowing conditions for optimized separation and is achieved by controlling pressure and fluid levels within the vessel. Temperature, controlled upstream of the separator, is another important factor. The fixed internal components inside the separator vessel (inlet diverter, baffle plates, weir, coalescer/defoamer, and demister) also assist in this process. Once stable process conditions prevail, gas, oil/condensate, and water rates can be measured in the gas and liquid meter runs on the separator outlet lines. The vessel is protected from overpressure by two independent safety relief valves on a contained vent line.

Configuration and flexibility of internal components allow use of a standard manway. Pressure safety valve on vessel with relief line to edge of skid, diagonally opposed grounding points on baseskid, and explosion-proof lighting at the front and rear of the unit enhance operational safety. NuFlo liquid meters enable analog and digital recording options. Flanged adapter spools provided to allow retrofit of alternative liquid meter types. Flanged nozzle provision on vessel to allow optional Hi-Lo pressure and level alarms and shutdown sensors. Internally coated with Belzona 1391 for protection and extended vessel life. CSC/DNV certified frame and skid enable stacking of units for increased durability and mobility. Four-point lifting sling and integral forklift pockets provide flexiblility to handling and movement. Skid-mounted tool box containing ancillary equipment improves operational efficiency.

Applications
Offshore and land operations Drillstem testing Well cleanups Production/well testing Early-production facilities

Features, Advantages and Benefits


Pressure, temperature, and sampling ports on inlet and outlet lines enable maximum measurement and sampling in all phases. Full-bore bypass manifold with isolation valves enables routing of inlet effluent to gas, oil, and water outlets. Check valve fitted to vessel inlet nozzle.

valleyvesselfabricators.com

2010 Valley Vessel Fabricators Inc. All rights reserved.

Surface Well Testing


22310 N. Moorefield Rd. Edinburg, TX 78541

Three-Phase Well Test Separator


Specifications
Model NB 405 Nominal vessel size (diameter length) (in. ft/cm m) Process design pressure at 122 F (psi/MPa) Process design temperature (F/C) Maximum working pressure at 250 F (psi/MPa) Maximum liquid rate (high liquid level) (bbl/d, m3/d) Maximum gas rate (low liquid level) (MMcfd) Service conditions Outside dimensions (L W H) (ft/m) Approximate empty weight (lb/kg) Fluid inlet Fluid outlet - gas Fluid outlet - oil Fluid outlet - water Fluid outlet - vent Full bore valves and bypass manifold Pressure sensing points Temperature sensing points PVT fluid sampling points Liquid sampling points Gas measurement equipment Oil measurement equipment Water measurement equipment Vessel pressure control equipment on gas line Oil level control equipment on oil line Water level control equipment on water line Safety devices Internal coating 21 100 106.68 3.81 1,440 9.928 -20 to 250 -29 to 121 2.000 13.789 13,000 2,066.79 30 H 2 S / CO2 17.42 7.25 7.33 5.31 2.21 2.24 8,091 3,670 3 in 4 in 2 in 2 in 2 in Yes Inlet, gas, oil and water lines Inlet, gas, oil and water lines Gas and oil lines Inlet, oil and water lines 4-in DC Daniel orifice meter with 5.761-in. LB and 3-pen static pressure/temperature and differential pressure Barton recorder 2-in. Nu-Flo turbine meter with MCII+ 2-in. Nu-Flo turbine meter with MCII+ 3-in. Fail-open pneumatic pressure control valve with C1 pressure controller 2-in. Fail-closed pneumatic level control valve WellMark snap pilot 2-in. Fail-closed pneumatic level control valve WellMark snap pilot 2 2 x 1-in. pilot operated pressure safety valves mounted directly on independent vessel nozzels with 2-in. vent line to base skid edge 2 grounding points on opposite diagonals of base skid Belzona 1391 ASME VIII Div I ANSI B.31.3 Applied codes NACE MR-01-75 DNV 2.7-1 CSC/ISO 1496-1

Options
Hi-Lo pressure and level alarms Oilgear velocity and BARTON positive displacement oil and water meters Electronic data acquisition system Other sizes and specifications available upon request

NuFlo, Oilgear, Belzona and Barton are trademarks of their respective owners.

valleyvesselfabricators.com

2010 Valley Vessel Fabricators Inc. All rights reserved.

VVF products and services are subject to the Companys standard terms and conditions, available on request or at valleyvesselfabricators.com. For more information contact an authorized VVF representative. Unless noted otherwise, trademarks and service marks herein are the property of VVf. Specifications are subject to change without notice. VVF sells its products and services in accordance with the terms and conditions set forth in the applicable contract between VVF and the client.