Product Information: For The Detection of C Arbon D Ioxide
Product Information: For The Detection of C Arbon D Ioxide
F eatures :
* * * * High s elec tivity to 2 CO C ompac t s ize L ow dependenc y on humidity L ong life
Product Information
T he T G S 4160 is a hybrid s ens or unit compos ed of a carbon dioxide s ens itive element and a thermis tor. A wide range of 350~30,000ppm of carbon dioxide can be detected by T G S 4160, making it ideal for usage in a variety of applications. T he C O 2 s ens itive element cons is ts of a s olid electrolyte formed between two electrodes , together with a printed heater (P t) s ubs trate. B y monitoring the change in electromotive force (E MF ) generated between the two electrodes , it is pos s ible to meas ure C O 2 gas concentration. Ads orbent (zeolite) is filled between the internal cover and the outer cover for the purpos e of reducing the influence of interference gas es . T G S 4160 exhibits a linear relationship between E MF and C O 2 gas concentration on a logarithmic s cale. T he s ens or dis plays good long term s tability and s hows excellent durability agains t the effects of high humidity. T he figure below repres ents typical s ens itivity characteris tics of T G S 4160. T he Y -axis is indicated as E MF which is defined as follows : E MF =E MF 1 - E MF 2 T he figure below s hows typical humidity dependency for an energized s ens or. Again, the Y -axis is indicated as E MF which is defined as follows : E MF =E MF 1 - E MF 2
where
E MF 1=E MF in 350 ppm C O 2 E MF 2=E MF in lis ted gas concentration S ensitivity C haracteristics:
140 120 100
C O2 CO E tO H
where
E MF 1=E MF in 350 ppm C O 2 E MF 2=E MF in 1000ppm C O 2 H umidity D ependency:
430 400 370
E MF (mV)
70 60 E MF (350ppm C O2) 50
E MF (mV)
E MF (mV)
340 310 280 250 220 0 20 40 60 80 100 R elative Humidity (%) E MF (350ppm C O2 - 1000ppm C O2)
40 30 20 10 0
G as C oncentration (ppm)
IMP OR T A NT NOT E : OP E R AT ING C ONDIT IONS IN WHIC H T HE S E S E NS OR S AR E US E D WILL V AR Y WIT H E AC H C US T OME R S S P E C IF IC AP P LIC AT IONS . WE S T R ONG LY R E C OMME NDS C ONS ULT ING OUR T E C HNIC AL S T AF F B E F OR E DE P LOY ING T HE S E S E NS OR S IN Y OUR AP P LIC AT ION AND, IN P AR T IC ULAR , WHE N C US T OME R S T AR G E T G AS E S AR E NOT LIS T E D HE R E IN. WE C ANNOT AS S UME ANY R E S P ONS IB ILIT Y F OR ANY US E OF IT S S E NS OR S IN A P R ODUC T OR AP P LIC AT ION F OR WHIC H T HE S E S E NS OR HAS NOT B E E N S P E C IF IC ALLY T E S T E D.
functions as a kind of battery, the E MF value its elf would drift us ing this bas ic measuring circuit. However, the change of E MF value ( E MF ) s hows a s table relations hip with the change of C O 2 concentration. T herefore, in order to obtain an accurate meas urement of C O 2, a special microprocessor for signal proc e s s ing s hould be us e d with T G S 4160. F igaro can provide a s pecial evaluation s ens or module (AM-4) for T G S 4160.
VH
Top V ie w (T G S 4160)
1
T hermis tor
RH R Th V E MF
6 5
T hermis tor
2 3
Operational Amplifier Input impedance > 100G B ias current < 1pA +
V out
S pecifications:
Mode l numbe r S e ns ing e le me nt type T a rge t ga s e s T ypic a l de te c tion ra nge m H e a te r re s is ta nc e H e a te r c urre nt E le c tric a l c ha ra c te ris tic s unde r s ta nda rd te s t c onditions H e a te r powe r c ons umption H e a te r volta ge E le c tromotive forc e S e ns itivity S e ns or c ha ra c te ris tic s R e s pons e time RH IH PH VH
E MF E MF
T op view
G A R O F I
17.7 1.0
Me a s ure me nt a c c ura c y . H
24.3 1.0
C O 2 in a ir a t 2 0 2 C , 6 5 5 % R H
H
= 5 . 0 0 . 0 5 V D C 7 da ys
White Dot
45 1 30'
1.0 0.1
5
2 45 1 30'
9.5 0.2
A: Lead wires
B ottom view
(u/m = mm)
Due to continuous product improvement, the design and technical specifications are to subject change without prior notice
29-M-1003, Shin-Ashiya-Kami, Suita-shi, Osaka 565-0804, Japan Tel: +81-6-6876-9035 Fax: +81-6-6876-9135 e-mail: [email protected] URL: http://www.tashika.co.jp
TBS LTD.,