Design of Tension Members: Part 3 of AISC/LRFD Manual Chapters B, D and J of The Specifications
Design of Tension Members: Part 3 of AISC/LRFD Manual Chapters B, D and J of The Specifications
Design of Tension Members: Part 3 of AISC/LRFD Manual Chapters B, D and J of The Specifications
TensionDesign.doc
Notations:
t
Ag
Ae
Resistance factor for tension (0.9 for yielding; 0.75 for fracture). Gross cross-sectional area. Effective net area (reduction of the net area to account for stress concentrations at holes and shear lag effects where not all the cross-sectional elements are connected to transmit the load).
An
U
Net cross-sectional area (gross area minus the areas of the bolt holes). The reduction coefficient. Whenever the tension is transmitted through some but not all of the cross-sectional elements of the tension member U = 1 x / l 0.9 (such as angle section where only one leg of the angle is connected to a gusset plate). Approximate values of U used prior to the current LRFD may also be used according to LRFD Commentary-B3. Distance from the plane of shear transfer to the centroid of the tension member cross-section. Length of the connection in the direction of loading. Specified minimum yield stress. Specified minimum ultimate stress. Nominal axial strength. Required axial strength. Laterally unsupported length of the member. Radius of gyration (smallest).
Fy
Fu Pn Pu
TensionDesign.doc
Requirements
The design strength t Pn is taken as the smaller of the yielding limit state and the fracture limit state: 1. Yielding failure of the gross cross-section
t Pn = t Fy Ag = 0.90 Fy Ag
2. Fracture of the net cross-section
t Pn = t Fu Ae = 0.75Fu Ae
where Ae = UAn .
Design requirement:
Pu t Pn
or
t Pu
Pu
L / r 300
AISC LRFD also requires the following considerations (Refer to Section J4 of the AISC LRFD Specifications): 1. Shear Rupture: Pn = (0.6 Fu )Anv
= 0.75
3. Shear-Tension Combination:
TensionDesign.doc
(
(
)
)
Agv = the gross area subject to shear Agt = the gross area subject to tension Anv = the net area subject to shear Ant = the net area subject to tension
= 0.75
The foregoing failure modes are referred to as Block Shear failure. Block shear is a failure phenomenon at the bolted connection for the member. The member or the gusset plate can shear-off and/or rupture in tension. There can be several modes of block shear failure and all of these need to be analyzed. Failure can happen in either yielding or fracture in all modes. We calculate the yield capacity on the gross area and the fracture capacity on the net area. Block shear capacity is the combined shear and tensile capacity of the failure mode (smallest capacity governs).
Design Procedure
Make sure that all three criteria described above are satisfied. There is no standard rule for designing tension members, but it is useful to follow the basic three steps:
TensionDesign.doc
1. Calculate the design load P u. 2. Calculate (a) Required gross area ( Ag ) (b) Required (effective) net area ( An or Ae ) (c) Radius of gyration ( r ). 3. Pick a member and try different sections that satisfy the criteria. Choose the lightest member. 4. Check other criteria.
TensionDesign.doc