VNX5100

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Next-generation SAN storage, optimized for virtualized applications

EMC VNX5100
The EMC VNX family delivers industry-leading innovation and enterprise capabilities for block storage in a scalable, easy-to-use solution.

SAN storage for multi-protocol Powerful new multi-core Intel CPUs with 6-Gb/s SAS backend Administration simplicity with EMC Unisphere Flash-optimized with auto-tiering Easy storage provisioning from the #1 provider of storage for virtualized environments

A robust platform for consolidation of legacy block storage and direct-attached application storage, the VNX series enables organizations to dynamically grow, share, and cost-effectively manage multiprotocol block storage access. At the same time, it supports iSCSI, Fibre Channel, and FCoE access for high-bandwidth and latency-sensitive block applications.

supported protocols to ensure successful deployments of virtualized infrastructures through all phases of implementation.

VNX software
The VNX series software is available in two comprehensive packages to ensure customers have all of the necessary capabilities to protect and manage their information. The VNX Total Protection Pack includes replication capabilities, point-in-time recovery features such as snaps and clones combined with automated application copies for assured recovery, along with monitoring and alerting for compliance with protection policies. The VNX Total Value Pack includes all of the protection features all the protection functions of the previous pack, plus features to keep data safe from changes, deletions, and malicious activity. All VNX software is managed through Unisphere.

Manage, monitor, and tune


EMC Unisphere makes it easy to manage VNX systems from anywhere with a simple, integrated user interface for distributed storage environments. The Unisphere dashboard is a single screen for at-aglance management and reporting, enabling administrators to gain instant and actionable knowledge about whats occurring across the entire environment. Unispheres single sign-on automatically discovers all VNX, EMC CLARiiON, EMC Celerra, and EMC RecoverPoint SE installations in the environment for seamless configuration.

Continuous availability
The VNX series is architected to provide five-nines availability in mission-critical business environments. VNX availability and redundancy features include: Up to 12.8 gigabytes of mirrored write cache, where each storage processor contains both primary cached data for its LUNs and a secondary copy of the cache for its peer storage processor Battery backup to allow for an orderly shutdown and cache destaging to vault disks to ensure data protection in the event of a power failure RAID protection levels 0, 1, 1/0, 3, 5, and 6all of which can co-exist in the same array simultaneously to match different protection requirements Proactive hot sparing enhances system robustness and delivers maximum reliability and availability Redundant data paths, power supplies, drive connections, and storage processors all with nondisruptive field replacement capabilities Continuous system monitoring, call-home notification, and advanced remote diagnostics

Optimize your performance


The VNX series has been designed to take advantage of the latest innovation in Flash drive technology, maximizing the storage systems performance and efficiency while minimizing cost per gigabyte. When even a few Flash drives are combined with the EMC FAST Suite an unrivaled set of software that tiers data across heterogeneous drives and boosts the most active data to cache customers receive the optimal benefits of a FLASH 1st strategy.

Use storage capacity more efficiently


The VNX series is delivered with built-in features to help ensure redundant, inactive, or anticipated data doesnt consume valuable storage resources. Block compression, intended for relatively inactive LUNs such as backup copies and static data repositories, automatically compresses data, enabling customers to recapture capacity and reduce the data footprint by up to 50 percent.

Virtual environments
The VNX series is the ideal mid-tier system for virtualized application environments. Whether the customer environment is VMware, Microsoft Hyper-V, or Xen-based, VNX is fully certified for all

www.bull.com

EMC VNX5100
BLOCK COMPONENTS
Min/Max. Disk Drives Array Enclosure 4/75 3U Disk Processor Enclosure (Holds 15x3.5 or 25x2.5 SAS/ Flash drives) Drive Enclosure Options 25 x 2.5 SAS/Flash : 2 U , 15 x 3.5 SAS/Flash drives : 3 U Standby Power System 1U 1.2KW RAID Options 0/1/10/3/5/6 CPU/Memory per Array Intel Xeon 5600/8 GB Max Block Flex IO Modules per Array 0 Embedded IO Ports per Array 8 FC ports and 2 BE SAS buses Max Total Ports per Array 8 2/4/8 Gb/s FC 8 1 GBaseT iSCSI N/A 1 GbE iSCSI Min/Max N/A Max FCOE N/A 6 Gb/s SAS Buses for DAE Connections 2 Disk Array Enclosure

Technical Specifications
PHYSICAL SPECIFICATIONS (Cont'd)
3.5": 5.25 in (13.34 cm) x 17.6 in (44.75 cm) x 14 in (35.56 cm); 2.5": 3.45 in (8.76 cm)x 17.62 in (44.75 cm) x 13 in ( 33.02) 1.75 in/4.45 cm x 17.5 in/44.45 cm x 20 in/50.8 cm 3.5": Full: 96.4 (43.8 kg); 2.5": Full: 73.4 (33.36 kg) 3.5": Full: 68 (30.9 kg); 2.5": Full: 45 (20.45 kg) 18 lb/8.16 kg

Control Station Weight Disk Processor Enclosure Disk Array Enclosure Control Station

ENVIRONMENT
Temperature Temperature Gradient Humidity Altitude 50104 F (1040 C), 18 F/hr (10 C/hr) 20% to 80% (non-condensing) 7,500 ft. (2,286.4 m) @ 104 F (40 C) max, 10,000 ft (3,048 m) @ 98.6 F (37 C) max

FILE COMPONENTS
# File X-Blades # Control Stations X-Blade: CPU/Memory Max File Flex IO Modules per X-Blade Max Ports per X-Blade Min/Max 2/4/8 Gb/s FC N/A N/A N/A N/A N/A N/A

POWER
Input Voltage Frequency Power consumption Disk Processor Enclosure Disk Array Enclosure Control Station Heat Dissipation Disk Processor Enclosure Disk Array Enclosure Control Station 100 to 240 Vac 10%, single-phase, 47 to 63 Hz 3.5 ": 415 VA (390 W) max / 2.5": 395 VA (385 W) max 3.5": 280 VA (235 W) max / 2.5 ": 250 VA (230 W) max 132 VA (104 W) max 3.5": 1,330 Btu/hr max; 2.5": 1,320 Btu/hr max 3.5": 800 Btu/hr max; 2.5" : 785 Btu/hr max 300 Btu/hr max

FUNCTIONNAL LIMITS
Max Raw Capacity Max SAN Hosts Max Number of Pools Max Number of LUNs Max LUN Size Max File System Size Max Usable File Capacity per X-Blade OS Support 150 TB 512 10 512 2 TB N/A N/A See EMC E-lab Navigator on EMC Powerlink

VNX CONNECTIVITY
Block FLEX IO Module Management 4 Port Fibre Channel, 4 Port 1 Gb/s iSCSI with TOE, 2 Port 10 Gb/s iSCSI with TOE, 2 Port 10 GbE FCoE LAN 2 x 10/100/1000 Copper GbE

REGULATORY & SAFETY


Safety UL 60950; CSAC 22.2-60950, FN 60950, Manufactured under an ISO 9000-registered quality system, ETSI EN 300 386 FCC Class A EN55022 Class A, CE Mark VCCI Class A (for Japan), ICES-003 Class A (for Canada) AS/NZS 3548 Class A (for Australia/New Zealand), EN55024 Immunity, ITE BSMI Class A (for Taiwan)

Electromagnetic Compatibility (EMC)

DRIVES SUPPORTED
3.5" HDD SAS 15Krpm 3.5" HDD SAS 10Krpm 2.5" HDD SAS 10Krpm 3.5" HDD NL (Near Line) 7.2Krpm 3.5" SDD SAS 300 GB, 600 GB 300 GB, 600 GB, 900 GB 300 GB, 600 GB, 900 GB 1 TB, 2 TB, 3 TB 100 GB, 200 GB

WARRANTY
Standard warranty World Wide; 3 years Hardware Support, 9x5, Next Business Day, parts only, Customer in charge of replacement for some components Bulls GlobalCare offer: Bronze, Silver, Gold levels; depends on location

PROTOCOLS AND FACILITIES SUPPORTED


ABE for Microsoft Windows Server 2003; ARP; Block Protocols: iSCSI, FCP, and FCoE; Ethernet Trunking; Failsafe Networking;ICMP, Kerberos Authentication, LDAP; LDAP signing for Windows; Link Aggregation; UNIX archive utilities; NDMP; NIS; NSM, Portmapper; NTP, NTLM; RIP; SNMP; SNTP; Virtual LAN Extended Warranty

2013 Copyright Bull SAS All rights reserved - On-the-fly printed on 13/08/2013 10:02:00

VNX SOFTWARE
Management Software Supported Protocols Base Software Software Suites Unisphere for Block FC included EMC Virtual Provisioning FAST Suite; Security and Compliance Suite; Local Protection Suite; Remote Protection Suite; Application Protection Suite Protection Pack, Total Value Pack VNX Monitoring and reporting and OE32 Local Protection suite

Software Packs Additionnal Options

PHYSICAL SPECIFICATIONS
Size (HxWxD) Disk Processor Enclosure 3.5": 5.25 in (13.34 cm) x 17.5 in (44.45 cm) x 24.25 in (61.6 cm); 2.5": 5.25 in (13.34 cm) x 17.5 in (44.45 cm) x 24.25 in (61.6 cm)

Bull SAS - Bull acknowledges the rights of proprietors of trademarks mentioned herein. Bull reserves the right to modify this document at any time without notice. Some offers or parts of offers described in this document may not be available in your country. Please consult your local Bull correspondent for information regarding the offers which may be available in your country. All trademarks and registered trademarks are the property of their respective owners. Bull SAS - rue Jean Jaurs - 78340 Les Clayes-sous-Bois France UK : Maxted Road, Hemel Hempstead, Herts HP2 7DZ USA : 285 Billerica Road, Chelmsford, MA 01824

www.bull.com