Em-2 Multiple Choice Question

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

1.

the difference between the synchronous speed and the actual speed of an induction motor is known as (a) Regulation (b) Back lash (c) Slip (d) Lag 2. Rotating magnetic field is produced in a.... (a) Single - phase induction motor (b) Three phase induction motor (c) DC series motor (d) AC series motor 3.The starting torque of a 1-phase induction motor is (a) High (b) Medium (c) Low (d) Zero 4. If an induction machine is run at above synchronous speed, it acts as (a) A synchronous motor (b) An induction generator (c) An induction motor (d) None of the above

5. In a synchronous motor, damper winding is provided to A. Stabilize rotor motion B. Suppress rotor oscillations C. Develop necessary starting torque D. Both B and C

6. Synchronous capacitor is A. An ordinary static capacitor bank B. An over excited synchronous motor driving mechanical load C. An over excited synchronous motor running without mechanical load D. None of the above

7. A synchronous machine is called as doubly excited machine because A. It can be over excited B. It has two sets of rotor poles

C. Both its rotor and stator are excited D. It needs twice the normal exciting current

8. If the field of a synchronous motor is under excited, the power factor will be A. Lagging B. Leading C. Unity D. More than unity 9. In a split phase motor, the running winding should have (a) high resistance and low inductance (b) low resistance and high inductance (c) high resistance as well as high inductance (d) low resistance as well as low inductiance

10. (a) (b) (c) (d) 11. (a) (b) (c) (d)

If the capacitor of a single-phase motor is short-circuited the motor will not start the motor will run the motor will run in reverse direction the motor will run in the same direction at reduced r.p.m. In capacitor start single-phase motors current in the starting winding leads the voltage current in the starting winding lags the voltage current in the starting winding is in phase with voltage in running winding none of the above

12. In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to (a) improve power factor (b) increase overload capacity (c) reduce fluctuations in torque (d) to improve torque

13. In a split phase motor (a) the starting winding is connected through a centrifugal switch (b) the running winding is connected through a centrifugal switch (c) both starting and running windings are connected through a centrifugal switch (d) centrifugal switch is used to control supply voltage

14. Which of the following motor will give relatively high starting torque ? (a) Capacitor start motor (b) Capacitor run motor (c) Split phase motor (d) Shaded pole motor Ans: a

15. In a shaded pole motor, the shading coil usually consist of (a) a single turn of heavy wire which is in parallel with running winding (b) a single turn of heavy copper wire which is short-circuited and carries only induced current (c) a multilayer fine gauge copper wire in parallel with running winding (d) none of the above

16. In a shaded pole single-phase motor, the revolving field is produced by the use of (a) inductor (b) capacitor (c) resistor (d) shading coils

17. In a single phase motor the centrifugal switch (a) disconnects auxiliary winding of the motor (b) disconnects main winding of the motor (c) reconnects the main winding the motor (d) reconnects the auxiliary winding of the motor

18. A shaded pole motor can be used for (a) toys (b) hair dryers (c) circulators (d) any of the above

19. For which of the applications a reluctance motor is preferred ? (a) Electric shavers (b) Refrigerators (c) Signalling and timing devices (d) Lifts and hoists

20. A single-phase induction motor is (a) inherently self-starting with high torque (b) inherently self-starting with low torque (c) inherently non-self-starting with low torque (d) inherently non-self-starting with high torque 21. (a) (b) (c) (d) 22. (a) (b) (c) (d) In split-phase motor auxiliary winding is of thick wire placed at the bottom of the slots thick wire placed at the top of the slots thin wire placed at the top of the slots thin wire placed at the bottom of the slots A reluctance motor is self-starting is constant speed motor needs no D.C. excitation all of the above

23. If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in (a) damage to the starting winding (b) damage to the centrifugal switch (c) overloading of running winding (d) none of the above 24. Three phase transformer can be constructed by (a) two types (b) three types (c) one type (d) none of the above 25. What is the power handling capacity of V-V circuit of transformer (a) 57.8% (b) 57.9% (c) 58.1% (d) 57.7% 26. Why scott connection of transformer is used (a) 3 phase to 2 phase

(b) 2 phase to 3 phase (c) 1 phase to 3 phase (d) none of the above 27. How many phase grouping of transformer are done (a) 3 (b) 4 (c) 5 (d) 6 28. Yy6 signifies what (a) 180 degree phase shift (b) -30 degree phase shift (c) +30 degree phase shift (d) no phase shift ANSWER IN TWO SENTENCE 29. What is difference between transformer and induction motor. 30. Synchronous motor is otherwise know as what and why.

You might also like