Vs-15Eth06Spbf, Vs-15Eth06-1Pbf: Vishay High Power Products
Vs-15Eth06Spbf, Vs-15Eth06-1Pbf: Vishay High Power Products
Vs-15Eth06Spbf, Vs-15Eth06-1Pbf: Vishay High Power Products
VS-15ETH06SPbF VS-15ETH06-1PbF
FEATURES
• Hyperfast recovery time
• Low forward voltage drop
• Low leakage current
• 175 °C operating junction temperature
Base
cathode • Single die center tap module
2
2 • Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
• Halogen-free according to IEC 61249-2-21 definition
• Compliant to RoHS directive 2002/95/EC
1 3 1 3 • AEC-Q101 qualified
N/C Anode N/C Anode
100 1000
TJ = 175 °C
100
IF - Instantaneous Forward
TJ = 175 °C
1
TJ = 150 °C TJ = 100 °C
10
TJ = 25 °C 0.1
0.01 TJ = 25 °C
0.001
1 0
0.5 1.0 1.5 2.0 2.5 3.0 0 100 200 300 400 500 600
1000
CT - Junction Capacitance (pF)
100
TJ = 25 °C
10
0 100 200 300 400 500 600
10
ZthJC - Thermal Impedance (°C/W)
PDM
D = 0.50 t1
D = 0.20
0.1 D = 0.10 t2
D = 0.05
D = 0.02 Notes:
Single pulse D = 0.01 1. Duty factor D = t1/t2 .
(thermal resistance) 2. Peak TJ = PDM x ZthJC + TC
.
0.01
0.00001 0.0001 0.001 0.01 0.1 1 10
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
180 100
IF = 30 A
Allowable Case Temperature (°C)
170 IF = 15 A
80
160 DC
60
150
trr (ns)
140
40
35 1000
VR = 390 V
TJ = 125 °C
30
Average Power Loss (W)
800 TJ = 25 °C
RMS Limit IF = 30 A
25
IF = 15 A
600
Qrr (nC)
20 D = 0.01
D = 0.02
15 D = 0.05 400
D = 0.10
10
D = 0.20
D = 0.50 200
DC
5
0 0
0 5 10 15 20 25 100 1000
Note
(1) Formula used: T = T - (Pd + Pd
C J REV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR
VR = 200 V
0.01 Ω
L = 70 μH
D.U.T.
D
dIF/dt
adjust
G IRFP250
(3)
trr
IF
ta tb
0
(4)
Qrr
(2)
IRRM 0.5 IRRM
dI(rec)M/dt (5)
0.75 IRRM
(1) dIF/dt
(1) dIF/dt - rate of change of current (4) Qrr - area under curve defined by trr
through zero crossing and IRRM
trr x IRRM
(2) IRRM - peak reverse recovery current Qrr =
2
(3) trr - reverse recovery time measured
(5) dI(rec)M/dt - peak rate of change of
from zero crossing point of negative
current during tb portion of trr
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.
1 2 3 4 5 6 7 8 9
D2PAK, TO-262
Detail A
D 17.90 (0.70)
H 15.00 (0.625)
(2)
1 2 3
3.81
MIN.
L2 (0.15)
B B 2.32
MIN.
(0.08)
A
E1 (3) 2.64 (0.103)
2 x b2 C 2.41 (0.096)
c
View A - A
2xb
0.010 M A M B ± 0.004 M B Base
Plating (4) Metal
2x e H b1, b3
Gauge
plane
(c) c1 (4)
0° to 8° B
Seating
Lead assignments plane
Lead tip L3 A1
L (b, b2)
Diodes
1. - Anode (two die)/open (one die) L4 Section B - B and C - C
2., 4. - Cathode Detail “A” Scale: None
3. - Anode Rotated 90 °CW
Scale: 8:1
Document Number: 95014 For technical questions concerning discrete products, contact: [email protected] www.vishay.com
Revision: 31-Mar-09 For technical questions concerning module products, contact: [email protected] 1
Outline Dimensions
Vishay High Power Products D2PAK, TO-262
1 2 3
C C
L2
B B L (2)
A
c E1 (3)
3 x b2
3xb A1
Section A - A
2xe
(4) Base
Plating metal
0.010 M A M B b1, b3
Lead assignments
c c1
Diodes (4)
1. - Anode (two die)/open (one die)
2., 4. - Cathode (b, b2)
3. - Anode
Lead tip Section B - B and C - C
Scale: None
MILLIMETERS INCHES
SYMBOL NOTES
MIN. MAX. MIN. MAX.
A 4.06 4.83 0.160 0.190
A1 2.03 3.02 0.080 0.119
b 0.51 0.99 0.020 0.039
b1 0.51 0.89 0.020 0.035 4
b2 1.14 1.78 0.045 0.070
b3 1.14 1.73 0.045 0.068 4
c 0.38 0.74 0.015 0.029
c1 0.38 0.58 0.015 0.023 4
c2 1.14 1.65 0.045 0.065
D 8.51 9.65 0.335 0.380 2
D1 6.86 8.00 0.270 0.315 3
E 9.65 10.67 0.380 0.420 2, 3
E1 7.90 8.80 0.311 0.346 3
e 2.54 BSC 0.100 BSC
L 13.46 14.10 0.530 0.555
L1 - 1.65 - 0.065 3
L2 3.56 3.71 0.140 0.146
Notes
(1) Dimensioning and tolerancing as per ASME Y14.5M-1994 (6) Outline conform to JEDEC TO-262 except A1 (maximum), b
(2) Dimension D and E do not include mold flash. Mold flash shall not (minimum) and D1 (minimum) where dimensions derived the
exceed 0.127 mm (0.005") per side. These dimensions are actual package outline
measured at the outmost extremes of the plastic body
(3) Thermal pad contour optional within dimension E, L1, D1 and E1
(4) Dimension b1 and c1 apply to base metal only
(5) Controlling dimension: inches
www.vishay.com For technical questions concerning discrete products, contact: [email protected] Document Number: 95014
2 For technical questions concerning module products, contact: [email protected] Revision: 31-Mar-09
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.