VS-15ETH06SPbF, VS-15ETH06-1PbF

Vishay High Power Products

Hyperfast Rectifier, 15 A FRED Pt®

VS-15ETH06SPbF VS-15ETH06-1PbF
FEATURES
• Hyperfast recovery time
• Low forward voltage drop
• Low leakage current
• 175 °C operating junction temperature
Base
cathode • Single die center tap module
2
2 • Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
• Halogen-free according to IEC 61249-2-21 definition
• Compliant to RoHS directive 2002/95/EC
1 3 1 3 • AEC-Q101 qualified
N/C Anode N/C Anode

D2PAK TO-262 DESCRIPTION/APPLICATIONS


State of the art hyperfast recovery rectifiers designed with
optimized performance of forward voltage drop, hyperfast
recovery time, and soft recovery.
The planar structure and the platinum doped life time control
PRODUCT SUMMARY guarantee the best overall performance, ruggedness and
reliability characteristics.
trr (typical) 22 ns
These devices are intended for use in PFC boost stage in the
IF(AV) 15 A
ac-to-dc section of SMPS, inverters or as freewheeling
VR 600 V diodes.
The extremely optimized stored charge and low recovery
current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.

ABSOLUTE MAXIMUM RATINGS


PARAMETER SYMBOL TEST CONDITIONS MAX. UNITS
Peak repetitive reverse voltage VRRM 600 V
Average rectified forward current IF(AV) TC = 140 °C 15
Non-repetitive peak surge current IFSM TJ = 25 °C 120 A
Peak repetitive forward current IFM 30
Operating junction and storage temperatures TJ, TStg - 65 to 175 °C

ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)


PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Breakdown voltage, VBR,
IR = 100 μA 600 - -
blocking voltage VR
V
IF = 15 A - 1.8 2.2
Forward voltage VF
IF = 15 A, TJ = 150 °C - 1.3 1.6
VR = VR rated - 0.2 50
Reverse leakage current IR μA
TJ = 150 °C, VR = VR rated - 30 500
Junction capacitance CT VR = 600 V - 20 - pF
Series inductance LS Measured lead to lead 5 mm from package body - 8.0 - nH

Document Number: 94003 For technical questions, contact: [email protected] www.vishay.com


Revision: 11-Mar-10 1
VS-15ETH06SPbF, VS-15ETH06-1PbF
Vishay High Power Products Hyperfast Rectifier,
15 A FRED Pt®

DYNAMIC RECOVERY CHARACTERISTICS (TC = 25 °C unless otherwise specified)


PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
IF = 1 A, dIF/dt = 100 A/μs, VR = 30 V - 22 30
IF = 15 A, dIF/dt = 100 A/μs, VR = 30 V - 28 35
Reverse recovery time trr ns
TJ = 25 °C - 29 -
TJ = 125 °C - 75 -
TJ = 25 °C IF = 15 A - 3.5 -
Peak recovery current IRRM dIF/dt = 200 A/μs A
TJ = 125 °C VR = 390 V - 7 -
TJ = 25 °C - 57 -
Reverse recovery charge Qrr μC
TJ = 125 °C - 300 -
Reverse recovery time trr IF = 15 A - 51 - ns
Peak recovery current IRRM TJ = 125 °C dIF/dt = 800 A/μs - 20 - A
Reverse recovery charge Qrr VR = 390 V - 580 - nC

THERMAL - MECHANICAL SPECIFICATIONS


PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Maximum junction and storage
TJ, TStg - 65 - 175 °C
temperature range
Thermal resistance,
RthJC - 1.0 1.3
junction to case per leg
Thermal resistance,
RthJA Typical socket mount - - 70 °C/W
junction to ambient per leg
Thermal resistance, Mounting surface, flat, smooth and
RthCS - 0.5 -
case to heatsink greased
- 2.0 - g
Weight
- 0.07 - oz.
6.0 12 kgf · cm
Mounting torque -
(5.0) (10) (lbf · in)
Case style D2PAK 15ETH06S
Marking device
Case style TO-262 15ETH06-1

www.vishay.com For technical questions, contact: [email protected] Document Number: 94003


2 Revision: 11-Mar-10
VS-15ETH06SPbF, VS-15ETH06-1PbF
Hyperfast Rectifier, Vishay High Power Products
15 A FRED Pt®

100 1000
TJ = 175 °C
100
IF - Instantaneous Forward

IR - Reverse Current (µA)


TJ = 150 °C
10 TJ = 125 °C
Current (A)

TJ = 175 °C
1
TJ = 150 °C TJ = 100 °C
10
TJ = 25 °C 0.1

0.01 TJ = 25 °C

0.001

1 0
0.5 1.0 1.5 2.0 2.5 3.0 0 100 200 300 400 500 600

VF - Forward Voltage Drop (V) VR - Reverse Voltage (V)


Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage

1000
CT - Junction Capacitance (pF)

100

TJ = 25 °C

10
0 100 200 300 400 500 600

VR - Reverse Voltage (V)


Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage

10
ZthJC - Thermal Impedance (°C/W)

PDM

D = 0.50 t1
D = 0.20
0.1 D = 0.10 t2
D = 0.05
D = 0.02 Notes:
Single pulse D = 0.01 1. Duty factor D = t1/t2 .
(thermal resistance) 2. Peak TJ = PDM x ZthJC + TC
.
0.01
0.00001 0.0001 0.001 0.01 0.1 1 10
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics

Document Number: 94003 For technical questions, contact: [email protected] www.vishay.com


Revision: 11-Mar-10 3
VS-15ETH06SPbF, VS-15ETH06-1PbF
Vishay High Power Products Hyperfast Rectifier,
15 A FRED Pt®

180 100
IF = 30 A
Allowable Case Temperature (°C)

170 IF = 15 A
80
160 DC

60
150

trr (ns)
140
40

130 Square wave (D = 0.50)


80 % rated VR applied
20 VR = 390 V
120 TJ = 125 °C
See note (1)
TJ = 25 °C
110 0
0 5 10 15 20 25 100 1000

IF(AV) - Average Forward Current (A) dIF/dt (A/µs)


Fig. 5 - Maximum Allowable Case Temperature vs. Fig. 7 - Typical Reverse Recovery vs. dIF/dt
Average Forward Current

35 1000
VR = 390 V
TJ = 125 °C
30
Average Power Loss (W)

800 TJ = 25 °C
RMS Limit IF = 30 A
25
IF = 15 A
600
Qrr (nC)

20 D = 0.01
D = 0.02
15 D = 0.05 400
D = 0.10
10
D = 0.20
D = 0.50 200
DC
5

0 0
0 5 10 15 20 25 100 1000

IF(AV) - Average Forward Current (A) dIF/dt (A/µs)


Fig. 6 - Forward Power Loss Characteristics Fig. 8 - Typical Stored Charge vs. dIF/dt

Note
(1) Formula used: T = T - (Pd + Pd
C J REV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR

www.vishay.com For technical questions, contact: [email protected] Document Number: 94003


4 Revision: 11-Mar-10
VS-15ETH06SPbF, VS-15ETH06-1PbF
Hyperfast Rectifier, Vishay High Power Products
15 A FRED Pt®

VR = 200 V

0.01 Ω

L = 70 μH
D.U.T.

D
dIF/dt
adjust
G IRFP250

Fig. 9 - Reverse Recovery Parameter Test Circuit

(3)
trr
IF
ta tb
0

(4)
Qrr
(2)
IRRM 0.5 IRRM

dI(rec)M/dt (5)

0.75 IRRM

(1) dIF/dt

(1) dIF/dt - rate of change of current (4) Qrr - area under curve defined by trr
through zero crossing and IRRM

trr x IRRM
(2) IRRM - peak reverse recovery current Qrr =
2
(3) trr - reverse recovery time measured
(5) dI(rec)M/dt - peak rate of change of
from zero crossing point of negative
current during tb portion of trr
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.

Fig. 10 - Reverse Recovery Waveform and Definitions

Document Number: 94003 For technical questions, contact: [email protected] www.vishay.com


Revision: 11-Mar-10 5
VS-15ETH06SPbF, VS-15ETH06-1PbF
Vishay High Power Products Hyperfast Rectifier,
15 A FRED Pt®

ORDERING INFORMATION TABLE

Device code VS- 15 E T H 06 S TRL PbF

1 2 3 4 5 6 7 8 9

1 - HPP product suffix


2 - Current rating (15 A)
3 - E = Single diode
4 - T = TO-220, D2PAK
5 - H = Hyperfast rectifier
6 - Voltage rating (06 = 600 V)
7 - S = D2PAK
-1 = TO-262
8 - None = Tube (50 pieces)
TRL = Tape and reel (left oriented, for D2PAK package)
TRR = Tape and reel (right oriented, for D2PAK package)
9 - PbF = Lead (Pb)-free

LINKS TO RELATED DOCUMENTS


Dimensions www.vishay.com/doc?95014
Part marking information www.vishay.com/doc?95008
Packaging information www.vishay.com/doc?95032

www.vishay.com For technical questions, contact: [email protected] Document Number: 94003


6 Revision: 11-Mar-10
Outline Dimensions
Vishay High Power Products

D2PAK, TO-262

DIMENSIONS FOR D2PAK in millimeters and inches

Conforms to JEDEC outline D2PAK (SMD-220) B


A Pad layout
(2)(3) A (E)
c2 11.00
E MIN.
(0.43)
A
(3) L1 4
9.65
MIN.
(D1) (3) (0.38)

Detail A
D 17.90 (0.70)
H 15.00 (0.625)
(2)
1 2 3
3.81
MIN.
L2 (0.15)
B B 2.32
MIN.
(0.08)
A
E1 (3) 2.64 (0.103)
2 x b2 C 2.41 (0.096)
c
View A - A
2xb
0.010 M A M B ± 0.004 M B Base
Plating (4) Metal
2x e H b1, b3
Gauge
plane
(c) c1 (4)
0° to 8° B
Seating
Lead assignments plane
Lead tip L3 A1
L (b, b2)
Diodes
1. - Anode (two die)/open (one die) L4 Section B - B and C - C
2., 4. - Cathode Detail “A” Scale: None
3. - Anode Rotated 90 °CW
Scale: 8:1

MILLIMETERS INCHES MILLIMETERS INCHES


SYMBOL NOTES SYMBOL NOTES
MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX.
A 4.06 4.83 0.160 0.190 D1 6.86 8.00 0.270 0.315 3
A1 0.00 0.254 0.000 0.010 E 9.65 10.67 0.380 0.420 2, 3
b 0.51 0.99 0.020 0.039 E1 7.90 8.80 0.311 0.346 3
b1 0.51 0.89 0.020 0.035 4 e 2.54 BSC 0.100 BSC
b2 1.14 1.78 0.045 0.070 H 14.61 15.88 0.575 0.625
b3 1.14 1.73 0.045 0.068 4 L 1.78 2.79 0.070 0.110
c 0.38 0.74 0.015 0.029 L1 - 1.65 - 0.066 3
c1 0.38 0.58 0.015 0.023 4 L2 1.27 1.78 0.050 0.070
c2 1.14 1.65 0.045 0.065 L3 0.25 BSC 0.010 BSC
D 8.51 9.65 0.335 0.380 2 L4 4.78 5.28 0.188 0.208
Notes
(1) Dimensioning and tolerancing per ASME Y14.5 M-1994 (7) Outline conforms to JEDEC outline TO-263AB
(2) Dimension D and E do not include mold flash. Mold flash shall not
exceed 0.127 mm (0.005") per side. These dimensions are
measured at the outmost extremes of the plastic body
(3) Thermal pad contour optional within dimension E, L1, D1 and E1
(4) Dimension b1 and c1 apply to base metal only
(5) Datum A and B to be determined at datum plane H
(6) Controlling dimension: inch

Document Number: 95014 For technical questions concerning discrete products, contact: [email protected] www.vishay.com
Revision: 31-Mar-09 For technical questions concerning module products, contact: [email protected] 1
Outline Dimensions
Vishay High Power Products D2PAK, TO-262

DIMENSIONS FOR TO-262 in millimeters and inches


Modified JEDEC outline TO-262
(Datum A) (2) (3) A B
E A c2 E
A
(3) L1
Seating D1 (3)
plane
D

1 2 3
C C
L2

B B L (2)

A
c E1 (3)
3 x b2
3xb A1
Section A - A
2xe
(4) Base
Plating metal
0.010 M A M B b1, b3
Lead assignments
c c1
Diodes (4)
1. - Anode (two die)/open (one die)
2., 4. - Cathode (b, b2)
3. - Anode
Lead tip Section B - B and C - C
Scale: None

MILLIMETERS INCHES
SYMBOL NOTES
MIN. MAX. MIN. MAX.
A 4.06 4.83 0.160 0.190
A1 2.03 3.02 0.080 0.119
b 0.51 0.99 0.020 0.039
b1 0.51 0.89 0.020 0.035 4
b2 1.14 1.78 0.045 0.070
b3 1.14 1.73 0.045 0.068 4
c 0.38 0.74 0.015 0.029
c1 0.38 0.58 0.015 0.023 4
c2 1.14 1.65 0.045 0.065
D 8.51 9.65 0.335 0.380 2
D1 6.86 8.00 0.270 0.315 3
E 9.65 10.67 0.380 0.420 2, 3
E1 7.90 8.80 0.311 0.346 3
e 2.54 BSC 0.100 BSC
L 13.46 14.10 0.530 0.555
L1 - 1.65 - 0.065 3
L2 3.56 3.71 0.140 0.146
Notes
(1) Dimensioning and tolerancing as per ASME Y14.5M-1994 (6) Outline conform to JEDEC TO-262 except A1 (maximum), b
(2) Dimension D and E do not include mold flash. Mold flash shall not (minimum) and D1 (minimum) where dimensions derived the
exceed 0.127 mm (0.005") per side. These dimensions are actual package outline
measured at the outmost extremes of the plastic body
(3) Thermal pad contour optional within dimension E, L1, D1 and E1
(4) Dimension b1 and c1 apply to base metal only
(5) Controlling dimension: inches

www.vishay.com For technical questions concerning discrete products, contact: [email protected] Document Number: 95014
2 For technical questions concerning module products, contact: [email protected] Revision: 31-Mar-09
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.

Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.

Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.

Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.

No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.

Material Category Policy


Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.

Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.

Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.

Revision: 02-Oct-12 1 Document Number: 91000

You might also like