635091384224950000-Power & Control Cable Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 33

LT/HT Power &

Control Cables

Catalogue 2013

HT Power Cables upto 66kV


1.1 kV Power Cables
1.1 kV Copper Control Cables

Index

Manufacturing Process

Introduction
Manufacturing Process
Manufacturing of Cables
Advantages
Cable ranges at a glance

5
6
7
8-9

LT Power & Control Cable


1.1 kV Single Core, PVC Insulated, Un-armoured Cables
1.1 kV Two Core, PVC Insulated, Un-armoured Cables
1.1 kV Three Core, PVC Insulated, Un-armoured Cables
1.1 kV Three & Half Core, PVC Insulated, Un-armoured Cables
1.1 kV Four Core, PVC Insulated, Un-armoured Cables

12
13
14
15
16

1.1 kV Single Core, PVC Insulated, Armoured Cables


1.1 kV Two Core, PVC Insulated, Armoured Cables
1.1 kV Three Core, PVC Insulated, Armoured Cables
1.1 kV Three & Half Core, PVC Insulated, Armoured Cables
1.1 kV Four Core, PVC Insulated, Armoured Cables

17
18
19
20
21

1.1 kV 1.5 sq. mm Copper Cond. PVC Insulated, Un-armoured / Armoured Cables
1.1 kV 2.5 sq. mm Copper Cond. PVC Insulated, Un-armoured / Armoured Cables

22
23

1.1 kV Single Core, XLPE Insulated, Un-armoured Cables


1.1 kV Two Core, XLPE Insulated, Un-armoured Cables
1.1 kV Three Core, XLPE Insulated, Un-armoured Cables
1.1 kV Three & Half Core, XLPE Insulated, Un-armoured Cables
1.1 kV Four Core, XLPE Insulated, Un-armoured Cables

24
25
26
27
28

1.1 kV Single Core, XLPE Insulated, Armoured Cables


1.1 kV Two Core, XLPE Insulated, Armoured Cables
1.1 kV Three Core, XLPE Insulated,Armoured Cables
1.1 kV Three & Half Core, XLPE Insulated,Armoured Cables
1.1 kV Four Core, XLPE Insulated, Armoured Cables

29
30
31
32
33

1.1 kV 1.5 sq mm Copper Cond. XLPE Insulated, Un-armoured / Armoured Cables


1.1 kV 2.5 sq mm Copper Cond. XLPE Insulated, Un-armoured / Armoured Cables

34
35

HT Power Cable
3.3 kV Single Core, XLPE Insulated, Armoured Cables - Non Screened
3.3 kV Three Core, XLPE Insulated, Armoured Cables - Non Screened

38
39

3.3 kV Single Core, XLPE Insulated, Armoured Cables - Screened


3.3 kV Three Core, XLPE Insulated, Armoured Cables - Screened

40
41

3.8/6.6 kV Single Core, XLPE Insulated, Armoured Cables


3.8/6.6 kV Three Core, XLPE Insulated, Armoured Cables

42
43

6.6/6.6 kV& 6.35/11Kv Single Core, XLPE Insulated, Armoured Cables


6.6/6.6 kV& 6.35/11Kv Three Core, XLPE Insulated, Armoured Cables

44
45

11/11kV Single Core, XLPE Insulated, Armoured Cables


11/11kV Three Core, XLPE Insulated, Armoured Cables

46
47

12.7/22 kV Single Core, XLPE Insulated, Armoured Cables


12.7/22 kV Three Core, XLPE Insulated, Armoured Cables

48
49

19/33 kV Single Core, XLPE Insulated, Armoured Cables


19/33 kV Three Core, XLPE Insulated, Armoured Cables

50
51

Basic assumption for current ratings & rating factors


Selection criteria of M/VHV cable size for primary distribution
Standard Drum lengths of Cables
Quality Control & Test
Selection Guide
Handling & Storage

52-53
54
55
56
57
58

Details for BIS Licences


For PVC Cables

For XLPE Cables

For 66kV Cables

IS:1554 (Part-1), 1988


CM/L No.: 81579 82

IS:7098 (Part-1), 1988


CM/L No.: 81896 92

IS:7098 (Part- 3)
CM/L No : 3098967

IS:1554 (Part-2), 1988


CM/L No.: 82594 85

IS:7098 (Part-2), 1985


CM/L No.: 83683 89

Manufacturing of Cables

Advantage

Cables with Aluminium and Copper conductor and polymer insulation are manufactured at Havells India Ltd. (Cable Works) Alwar.
Essentially cables comprise of conductors, insulation, inner-sheath, armour and outersheath. The brief description of the process is
mentioned as under:

In Havells Cable-polymers used for inner sheath are softer than


insulation or outer sheath & are compatible with temperature
ratings of cables & do not have deleteriocus effect on any other
component of cable.

CONDUCTOR
Havells Cables are available with both aluminum and copper
conductors. It is manufactured with solid/Stranded Circular/
Shaped Aluminium / Copper Conductor. Stranding makes Cables
exible and easy to handle while shaping makes them compact.
Compaction is provided to all stranded conductor constructions
as under:
1. Circular Conductor With one wire in the centre conductor
contains 6, 12, 18, 24, 30... wire layers in either unilay or
opposite helical directions. The conductor is sized upto 92%
compaction.
2. Shaped Conductors In all multicore cables from 16 Sq.
mm size, conductors are shaped. Compaction degree in
multicore power cables is upto 92%.

Thus improving electrical treeing characteristics and mechanical


strength of insulation.
Havells cables are friendly during continuous, emergency and
short circuit conditions.
Though there is no change in basic design of Havells cables yet
the latest manufacturing process gives improved reliability and
compactness to cables. The relative thermal expansion during
short circuit between dielectric and conductor is therefore limited
to minimum both in PVC & XLPE, thus limiting displacement of
cores in cables during short circuit.
Insulation for Havells Cables are strictly manufactured and applied
over conductor in accordance with National and International
specications:
National Specication

IS:5831/IS:7098

3. Segmental Conductor As a special case Havells cables of


1600 sq. mm are made up of segmental conductors.

International Specications

BS:6746/BS:5467/IEC:60502

The conductor is manufactured in equal segments and compacted,


then laid together. This reduces A.C. losses in the large sized
conductor, which are due to skin and proximity effects.

XLPE Cables with rated voltage over 3300V shall be provided with
conductor and insulation screening as follows:

Havells has special construction of conductor to suggest to its


customer for meeting their specic need.
Havells copper conductor cables are of the same construction that
of cables with Aluminium conductor except for high tensile strength,
superior conductivity, better exibility and ease of jointing, copper
cables are used in control, instrumentation, winding, submarine,
mining and ship wiring etc. etc applications.

SCREENING

Conductor
Screen

Semiconducting compound as per is:7098 part 2.

Insulation

Insulation screening shall consist of non-metalic

Screen

Part in combination with metalic part. Non metalic


part shall consist of either semi conducting
compound tape applied hellically or extruded layer
of semi conducting compound, applied directly
over insulation. Over this, metalic part (copper tape)
shall be applied hellically with overlap as per IS:7098
part 2.

All conductors for Havells cables are manufactured strictly in


accordance with National and International specications.
National specications

IS:8130

International specication

IEC:60228 / BS:6360

DIELECTRIC INSULATION
Insulation for Havells cables is strictly as per National and
International specications.
Havells cables are designed and manufactured with polymer
dielectrics to bear thermal and thermomechanical stresses safely
at continuous normal and short circuit temperature conditions.
Havells cables are available with both thermoplastic & thermo
setting insulations.
- PVC Cables

Thermoplastic dielectric

- XLPE Cables

Thermo setting dielectric

Havells PVC cables use PVC compounds that take care of over
load and short circuit current with both coarse & ne protection
systems.
Havells XLPE cables use XLPE compound with anti oxidant
stabilizers and traces of aromatic polynuclear hydrocarbon.

Conductor shall be screened with extruded

To avoid the cavities and voids formation in dielectric particularly


on bending operation of cable, perfect bonding of insulation and
screening is required. To ensure this Havells applying conductor
screen, insulation and insulation screen (non-metalic part) in one
operation through tripple extrusion.
LAYING UP
Cores are tested on line during production both for physical and
electrical characteristics. Control is observed within tight tolerance
limits for dimensions in case pf PVC/XLPE insulation. For multicore
cables cores are laid up on our latest laying up machine equipped
with sector correction equipment. In case of XLPE insulated cores
the same are cured so as to impart the requisite characteristics
both electrical and mechanical and then are laid up.
INNERSHEATH
Laid up cables are provided with inner sheath with high quality
of PVC which acts as bedding for steel wire / strip armouring.
Wherever required, ller cords are provided to maintain the
circularity to laid up cables.

Inner sheath is applied either with extrusion or by wrapping. In


Havells Cables though the inner sheath is closely applied on the
laid up cores, same can be stripped with ease without damaging
insulation.
The inner sheath dimensions are maintained strictly in accordance
with laid down specication .
Specication

For PVC Cables

IS:1554 (Part-I & II)

For XLPE Cables

IS:7098 (Part-I & II)

FINAL TESTING
Each Havells Cable is tested for all applicable Routine Tests.
From a lot of Cable one cable of each type is tested for Type tests,
as per relevant specications.
Havells conduct its testing at Havells India Ltd. cable plant at Alwar
for acceptance test as per specication.
Testing of Havells Cables are carried out as per Havells Work
Standards for testing, besides applicable standards.
ADVANTAGES OF PVC CABLES
1. A non-hygroscopic insulation almost unaffected by moisture.
2. Non-migration of compound permitting vertical installation.
3. Complete protection against most forms of electrolytic and
chemical corrosion.

ARMOURING
Mechanical protection to the cable is provided with armouring.
Havells single core cables are armoured with Aluminium or
Aluminium alloy wire/strips, thus avoiding magnetic hysteresis
losses on A. C. System.

4. A tough and resilient sheath with excellent re - resisting


qualities.
5. Good ageing characterstics.
6. Not affected by vibration.

Multicore cables are provided with galvanised steel wire/strips.


Havells cables are provided with galvanised wire armouring, where
cables are to run vertically and are subjected to stresses.

ADVANTAGES OF XLPE CABLES

Havells Mining cables are armoured with steel wire and tinned
copper wires, so as to provide conductivity of armour more than
75% of main conductor of cable.

2. Higher Short Circuit Rating.

Havells cables armour wires/strips are of low resistivity material


and meet the requirements of IS:3975.
Havells armoured cables are with almost 95% armour coverage.
OUTER SHEATH
All Havells Cables are provided with PVC/polymer outer sheath.
Havells Cables are manufactured with various characteristics of
sheathing compounds.
General purpose sheathing Compound

ST1

1. Higher Current Rating.

3. Longer Service Life.


4. For a short time it can withstand maximum 130oC and is
favourable to endure short circuit stresses.
5. It is less sensitive to the setting of the network protection.
6. Because of the thermosetting process taking place due the
effect of cross linking, the crack resistance is increased.
7. Due to the chemical cross-linking internal stresses are
reduced. Consequently the material is less sensitive during
manufacturing process to the setting of the cooling gradient.

Heat resistant Compound for sheath (H.R.) ST2

8. The thermal resistivity of cross-linked material is favourably low,


compared to thermoplastic material.

Fire Retardant Low

IEC 754 Part I

9. The low dielectric loss is a signicant advantage.

Smoke Compound

IEC 60332 Part I& III

(FRLS)

IEEE-383

10. The excellent mechanical features of the insulation improves


the protection against external effects.

ASTM-2843
ASTM-2863
Flame Retartant Compound (FR)

to EIL Specn.

Ultra Voilet Radiations Resistance Compound to ASTM G-53.


Anti Rodent and Anti Termite Compound.
PVC compounds used for Havells Cables are of various grades to
meet specications IS: 5831.
In order to be identied, Havells Cables have their name embossed/
printed/indented on outersheath at regular intervals on the outer
sheath of Havells Cables, Voltage Grade, cable size, trade name &
year of manufacture are embossed, as desired.
Cables are sequentially marked for length at every metre throughout
its length.

11. The resistance of the XLPE to acids, alkalies is outstanding and


is often compensating the adverse environmental inuences.

Cable range at a glance


Application
Cables for Power
Supply to
Residential,
Commercial &
Industrial units

Type & Size


PVC/XLPE Power cables for 1.1
& 3.3 kv for Electrical Substations
as per IS:1554 - I & 2
Sizes:
Single Core 10-1000 sq. mm
Multicore 6-630 sq. mm

Cable range at a glance


Options

Conductor - Stranded / Solid, Circular /


Shaped Aluminium / Copper
Insulation - PVC / HR PVC
Inner Sheath - PVC / HR PVC / FRLS / PVC
Unarmoured / Armoured - G.S. Round Wire/
Flat Strip or Aluminum Wire / Flat Strip
Outer Sheath - PVC/ HR PVC/ FRLS PVC

Heavy Duty
XLPE
Power cables for
Power
Generation
Distribution

XLPE Power cables


upto 19/33 kv grade 33 kv (E)
as per IS:7098 - I & II
Sizes :
Single Core : 25 - 1000 sq. mm
Multicore : 25 - 400 sq. mm

Conductor - Circular/Shaped - Aluminum/Copper


Insulation - XLPE
Innersheath - PVC / HR PVC / FRLS
Unarmoured / Armoured - G.S Round Wire /
Flat Strip or Aluminum Wire / Flat Strip
Outersheath - PVC / HR PVC / FRLS

Heavy Duty
copper
cables for Coal
Mines

Stranded bright annnealed


electrolytic copper conductor, PVC/
XLPE insulated / PVC sheathed
upto and including 3.3 kv as per
IS: 1554 - I&II / IS: 7098 - I & II
Sizes :
Multicore 25 to 400 sq. mm

Conductor - Circular / Shaped


Insulaton - PVC / XLPE
Innersheath- PVC / HR PVC / FRLS
Unarmoured/Armoured- Round Wire/Flat Strip
with conductivity not less than 75% of the phase
Conductor
Outer Sheath - PVC/ HR PVC / FRLS

PE/XLPE insulated 1.1 kv to 33 kv


as per IS:14255 & IS:7098-II

Conductor - Stranded Circular compacted


Aluminium
Insulation - PE/XLPE
Messenger conductor - All Aluminium Alloy-Bare/
Insulated
Street Light Cond. - Stranded Circular
Compacted Aluminium, Bare/Insulated

Arial Bunched /
Bundled required
for over head
power
distribution

Fire Survival
Cables for re
hazardous/ prone
areas

Copper Control
Cables for Power
Switch yard
Control /
Relay Equipment

Railway ignaling
Cables

Telecom / Switch
board cables for
Indoor
Telephones

Coaxial cables
for
Telcom /
Microwave /
CATV / MATV
industry

Annealed electrolytic copper


conductor, heat barrier, XLPE, LSZH
inner sheath G.S. wier and LSZH
outer sheath as per IS 7098-I/ BS
7846 testing as per IEC 331 &
BS 6387

Conductor - Solid/Stranded, Plain /Tinned


Heat Barrier - Mica Tape
Insulation - XLPE
Innersheath - Zero Halogen
Armoured - G.S. Round Wire/ Flat Strip
Outersheath - Zero Halogen

Annealed electrolytic copper


conductor, PVC/XLPE insulated,
PVC sheathed 650/ 1100V
grade as per IS: 1554-I & IS: 7098-I
Sizes :
1.5 / 2.5 sq. mm upto 61 core
4 & 6 Sq. mm upto 4 core

Conductor - Solid/Stranded, Plain /Tinned


Insulation - PVC/HR PVC/XLPE
Innersheath - PVC/HR PVC/FRLS/Zero Halogen
Unarmoured / Armoured - G.S. Round Wire /
Flat Strip
Outersheath - PVC/HR PVC/FRLS/Zero Halogen
Additional Option : Overall shielding with
Aluminum mylar tape with 100% coverage & 25%
overlap on laid up cores for static noise rejection.

Annealed Bare Copper conductor,


PVC insulated cores laid up PVC
sheath as per IRS-S-63/89 RDSO
& related specications
Sizes :
1.5 & 2.5 sq. mm upto 61 core
4 & 6 sq. mm upto 4 core

Screened/Unscreened - Aluminum mylar tape


Unarmoured/Armoured - G.S. Round Wire /
Flat Strip/Galvanised Tape
Additional Option :
Insulation/Inner/Outer Sheath - PVC
Inner/Outer sheath - PVC

Annealed Copper conductor,


PVC Insulated as per DOT TEC
Spec No: G/WIR-06/02
Sizes :
0.4 / 0.5 / 0.6 / 0.7 / 0.9 mm

Conductor - Tinned / Plain


Insulation - PVC / HR PVC / Nylon
Innersheath - PVC/ HR PVC/ FRLS Zero Halogen
Unarmoured / Armoured - G.S. round wire /
Flat Strip
Outer sheath - PVC/HR PVC/FRLS
AdditIonal Option - Individual / Overall pair/
Shielding / Screening

Available in specied RG
& UR Series as per MIL-C-17 /
BS: 2316 / IS: 5608 / IS: 11967
Sizes : Suitable for Impedance
of 50 / 75 / 100 / 125 ohms

Conductor - Plain / Tinned / Copper Clad Steel /


Silver Plated
Insulation - Solid / Foam / Semi air spaced
Screen - Single / Double braid
Sheath - PVC / HR PVC / FRLS / P.E

Cross Sectional View


Outer-Sheath
Armouring

Application

Type & Size

Options

Stranded Plain copper, PVC


insulated & PVC sheathed of
1.1kV grade as per IS: 694
Sizes : 3 core - 1.5 to 50 sq. mm

Insulation - PVC / HR PVC


Sheathing - PVC / HR PVC

Trinned cooper XLPO insulated &


LSZH sheathed 1100 Vac/ 1800
Vdc as per TUV specications
2PFG - 1169/08-2007

Conductor - Flexible trinned copper


Insulation - Cross linked polyolen compound
Sheath - XLPO/ LSZH compound

PVC Sheathed 225/650/


1100 V grade cables as per
BS: 5308 / DIN VDE 0815 &
816 / IS: 1554 / IEC: 189
Sizes:
0.5/0.75/1.0/1.5 sq. mm

Conductor - Standed / Solid, plain / tinned


Insulation - PVC / HR PVC / P.E / Zero Halogen
Shielding - Individual Pair / over all pairs
Drain wire - Solid Stranded
Innersheath - PVC / HR PVC
Zero Halogen
Unarmoured/Armoured-G.S. Round Wire, Flat
Strip Outersheath - PVC / HR PVC/ FRLS /
Zero Halogen

Flexible & Cord


Cables for
appliances,
Machine Tools &
Equipment Wiring

Multistrand, exible, bright


annealed electrolytic copper
conductor, PVC insulated and
sheathed upto 1100V as per IS:694
Sizes : Single, Two, Three or
Four core upto 25 sq. mm

Insulation - PVC / HR PVC / FRLS /


Zero Halogen
Unsheathed /Sheathed - PVC / HR PVC /
FRLS / Zero Halogen

Wiring Cables for


electrical industry

Multistrand Flexible, upto 1100V


grade PVC Cables as per IS: 694
Sizes :
Single core 1.0 - 630 sq. mm

Conductor - Bright Annealed Copper


Insulation - PVC/ HR PVC/ FRLS PVC /
Zero Halogen

Energy Cables
for Power Supply
to Telephone
Exchanges /
UPS /
Battery Backup /
Equipments

PVC Flexible Cables upto 1.1kv


grade as per IS:694
Sizes :
1.0 upto 240 sq. mm
Single / Multi Core

Conductor - Stranded / Solid bright


annealed Copper
Insulation - PVC / HR PVC / FRLS /
Zero Halogen

Air Field Lighting


Cables

Stranded plain annealed copper,


PVC insulated & PVC
sheathed of 5 kV grade
Sizes :
Single core 6 /16 sq.mm
and 2 x 6, 16 & 25

Insulation - PVC / XLPE

Flat cables for


Submersible
Pumps & Motors

Inner-Sheath

Cross Sectional View


Insulation
Conductor

Sheath

Insulation
Aluminium /
Copper Conductor

Solar cable for


Solar plant

PVC Outer-Sheath
Armouring
PVC Inner-Sheath
Filler
Stranded Conductor
Conductor Screening
XLPE Insulation
Insulation Screening
Metallic Screening

Instrumentation
Signal Cables for
Process control &
Instrumentation

Outer-sheath
Armour (outer layer)
Seprator (PVC tape)
Armour (inner layer)
Inner-Sheath

Conductor - Flexible trinned copper


Insulation - XLPO linked poly compound
Sheath - XLPO/ LSZH compound

Drain Wire
Outer Sheath
Armour
Inner Sheath
Drain Wire
Individual Pair Shield
Conductor
Insulation

Insulation
Conductor

Outer Sheath
Cu Tape Screening
Insulation Screening

Conductor
Insulation
Filler
Sheath

XLPE Insulation
Conductor Screening
Conductor
AAA
Messenger
Conductor

Insulation

Conductor

Conductor
Glass Mica Tape
Insulation
Inner Sheath
Armour
Outer Sheath

Outer Sheath
Armour
Inner Sheath
Conductor
Insulation

Color Skin
Natural PVC
Multistrand Flexible
Copper Conductor

Insulation

Conductor

Sheath

Outer Sheath
Armour
Inner Sheath
Conductor
Insulation

Outer Sheath
Armour
Inner Sheath
Conductor
Insulation

P.E. Insulation

Sheath

Braid

Inside View - Cable Factory

LT POWER &
CONTROL CABLE

LT POWER & CONTROL CABLE

FEATURES

XLPE INSULATED CABLE


s (IGHERCURRENTRATING
ANDEMERGENCYOVERLOADRATING
s 3UPEROIRSHORTCIRCUITRATING
s ,OWDIELECTRICLOSS
s -UCHBETTERINSULATIONRESISTANCE
s 2ESISTANTTOCHEMICALCORROSSIVEGASESETC
s "ETTERRESISTANCETOSURGECURRENTS
s -UCHLONGERLIFEOFTHECABLES

PVC INSULATED CABLE


s (IGHDIELECTRICSTRENGTHRESISTANCETO$#VOLTAGEEFFECTS
s (IGHMECHANICALSTRENGTHRESISTANCETOABRASION VIBRATIONAGEING
s 2ESISTANTTOMOSTACIDS ALKALIES TOTEMPORARYCONTACTWITHSOLVENTS
OILSANDLIQUIDFLUIDS
s &LAMERETARDANT DOESNOTSUPPORTCOMBUSTIONANDSELFEXTINGUISHING

INSULATED MATERIAL
s 8,0%
s 06#

APPLICABLE STANDARD
s )30ART 
s )30ART 

LT/HT Power & Control Cables

Table - 1

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Ref Specication : IS 1554 Part-1

Physical Parameters
Size
(Cross Sectional
Area)

Minimum No. of Strand in Conductor


Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

mm
(1.00)
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.20
2.40
2.60
3.00
3.40
3.40
3.40

mm
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.00
2.00
2.20
2.20
2.40
2.40
2.60

mm
9
10
11
11
12
13
15
17
19
21
23
25
27
30
34
38
43
46
50

With Al'm Cond.

With Al'm Cond.

AYY
Kg/Km
120
140
160
160
210
250
320
400
510
620
750
900
1100
1350
1700
2150
2700
3250
3950

YY
Kg/Km
150
180
230
260
370
460
610
800
1100
1350
1650
2000
2550
3200
4000
5100
6550
8200
10150

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.140
0.58
4.61
3.08
5.53
3.70
0.127
0.68
3.08
1.83
3.70
2.20
0.118
0.83
1.91
1.15
2.29
1.38
0.110
1.01
1.20
0.727
1.44
0.87
0.105
1.05
0.868
0.524
1.04
0.63
0.100
1.22
0.641
0.387
0.769
0.464
0.098
1.22
0.443
0.268
0.532
0.322
0.091
1.43
0.320
0.193
0.384
0.232
0.088
1.47
0.253
0.153
0.304
0.184
0.086
1.62
0.206
0.1240
0.247
0.1488
0.085
1.62
0.164
0.0991
0.197
0.1189
0.084
1.62
0.125
0.0754
0.151
0.0912
0.082
1.72
0.100
0.0601
0.122
0.0733
0.080
1.74
0.0778
0.0470
0.0961
0.0580
0.080
1.81
0.0605
0.0366
0.0759
0.0459
0.079
1.86
0.0469
0.0283
0.0610
0.0368
0.077
1.87
0.0367
0.0221
0.0503
0.0303
0.077
1.98
0.0291
0.0176
0.0422
0.0255
0.076
2.20

Approx. Weight of Cable


Size
(Cross Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Minimum No. of Strand in


Conductor
Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

Nominal Insulation
Thickness

Minimum
Inner Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

mm
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.20
2.40
2.60
3.00
3.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.70
0.70
0.70

mm
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.00
2.20
2.20
2.40
2.40
2.60
2.80
3.20
3.40
3.80

mm
14
16
17
17
19
21
24
26
30
32
34
37
42
46
52
58
65

With Al'm Cond.

With Cu Cond.

AYY
Kg/Km
240
320
390
350
480
580
700
880
1150
1350
1600
1950
2500
3000
3800
4800
6050

YY
Kg/Km
320
370
520
550
800
980
1300
1700
2300
2750
3350
4150
5350
6650
8450
10700
13800

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

2
3
4

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Normal Current Rating
For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps

39
38
35
39
37
35
49
48
44
51
51
47
65
64
60
66
65
64
85
83
82
86
84
84
110
110
110
100
100
105
130
125
130
120
115
130
155
150
165
140
135
155
190
175
205
175
155
190
220
200
245
195
170
220
250
220
280
220
190
250
280
245
320
240
210
290
305
260
370
270
225
335
345
285
425
295
245
380
375
310
475
325
275
435
400
335
550
345
295
480
425
355
590
390
320
550
470
375
660
450
380
610
530
425
725
500
415
680
590
740
870

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.30
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50
60.80
92.00
76.00
115.00

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

12

Cable Code : AYY/YY


Ref Specication : IS 1554 Part-1

Physical Parameters

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm and
above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Black
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


TWO CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES

Cross-sectional view

Cross-sectional view

Table - 2

Approx. Weight of Cable


Nominal Insulation
Nominal Outer Approx. OverThickness
Sheath Thickness all Dia of Cable

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

LT/HT Power & Control Cables

Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.87
0.083
0.42
0.868
0.524
1.04
0.63
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.0759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
32
27
27
41
35
35
40
34
35
50
44
45
55
45
47
70
58
60
70
58
59
90
75
78
90
76
78
115
97
105
110
92
99
140
120
125
135
115
125
165
145
155
160
140
150
205
180
195
190
170
185
240
215
230
210
190
210
275
235
265
240
210
240
310
270
305
275
240
275
350
300
350
320
275
325
405
345
410
355
305
365
450
385
465
385
345
420
490
485
530
425
380
475
540
460
605
465
415
540
640
550
785

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.28
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.55

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

13

LT/HT Power & Control Cables

Table - 3

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Ref Specication : IS 1554 Part-1

Physical Parameters

LT/HT Power & Control Cables

Table - 4

TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Ref Specication : IS 1554 Part-1

Physical Parameters

Approx. Weight of Cable


Minimum No. of Strand in
Conductor

Size
(Cross Sectional
Area)

Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

Nominal Insulation
Thickness

Minimum
Inner Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

mm
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.20
2.40
2.60
3.00
3.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.60
0.70
0.70
0.70

mm
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.20
2.20
2.20
2.40
2.60
2.80
3.00
3.40
3.60
4.00

mm
15
16
18
19
22
24
27
30
34
36
40
44
50
55
62
70
78

With Al'm Cond.

With Cu Cond.

AYY
Kg/Km
270
350
430
460
620
750
950
1250
1600
1850
2300
2800
3550
4300
5450
6850
8700

YY
Kg/Km
360
450
620
740
1100
1400
1800
2500
3300
4000
4900
6050
7850
9750
12400
15800
20200

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

2
3
4

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.87
0.083
0.42
0.868
0.524
1.04
0.63
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Aluminium
No's
6/6
6/6
6/6
12/6
15/6
15/12
15/12
30/15
30/15
30/15
53/30
53/30
53/30

Copper
No's
6/6
6/6
6/6
12/6
15/6
18/12
18/12
30/15
34/18
34/18
53/30
53/34
53/34

Nominal Insulation
Thickness

Minimum
Inner Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

mm
1.20/1.00
1.20/1.00
1.40/1.20
1.40/1.20
1.60/1.40
1.60/1.40
1.80/1.40
2.00/1.60
2.20/1.60
2.40/1.80
2.60/2.00
3.00/2.20
3.40/2.40

mm
0.30
0.30
0.30
0.40
0.40
0.50
0.50
0.50
0.60
0.60
0.70
0.70
0.70

mm
2.00
2.00
2.20
2.20
2.20
2.40
2.40
2.40
3.00
3.20
3.40
3.80
4.00

mm
23
26
28
32
37
40
44
48
55
60
68
77
87

With Al'm Cond.

With Cu Cond.

AYY
Kg/Km
750
850
1100
1400
1800
2250
2600
3200
4100
5000
6250
7950
10000

YY
Kg/Km
1250
1600
2100
2850
3800
4750
5650
7050
9150
11300
14300
18300
23300

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16
Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular, 16
Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow & Blue
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Sqmm
3X25+16
3X35+16
3X50+25
3X70+35
3X95+50
3X120+70
3X150+70
3X185+95
3X240+120
3X300+150
3X400+185
3X500+240
3X630+300

Minimum No. of Strand in


Conductor

Cross-sectional view

Cross-sectional view
1

Approx. Weight of Cable


Size
(Cross Sectional
Area)

2
3
4

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Normal Current Rating
For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
28
23
23
36
30
30
35
30
30
45
38
39
46
39
40
60
50
52
60
50
51
77
64
66
76
63
70
99
81
90
92
77
86
120
99
110
110
95
105
145
125
135
135
115
130
175
150
165
165
140
155
210
175
200
185
155
180
240
195
230
210
175
205
270
225
265
235
200
240
300
255
305
275
235
280
345
295
355
305
260
315
385
335
400
335
290
375
425
360
435
370
320
425
470
390
520
405
350
480
555
470
675

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50

Short Circuit Current


Reactance
Normal Current Rating
Max. Conductor
Approx. Conductor
Size
Capacitance
Rating for 1 Second
of Cable
D.C.Resistance at 20 C A.C.Resistance at 70 C
(Cross
of Cable
For Aluminium Conductor
For Copper Conductor
Duration
at 50 Hz
Sectional Area)
(Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ground Duct
Air
Ground Duct
Air
Aluminium Copper
Sqmm
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps K.amps K.amps
3X25+16
1.20
0.727
1.44
0.87
0.083
0.42
76
63
70
99
81
90
1.90
2.88
3X35+16
0.868
0.524
1.04
0.63
0.082
0.48
92
77
86
120
99
110
2.66
4.03
3X50+25
0.641
0.387
0.769
0.464
0.082
0.49
110
95
105
145
125
135
3.80
5.75
3X70+35
0.443
0.268
0.532
0.322
0.076
0.56
135
115
130
175
150
165
5.32
8.05
3X95+50
0.320
0.193
0.384
0.232
0.076
0.58
165
140
155
210
175
200
7.22
10.90
3X120+70
0.253
0.153
0.304
0.184
0.075
0.63
185
155
180
240
195
230
9.12
13.80
3X150+70
0.206
0.1240
0.247
0.1488
0.074
0.63
210
175
205
270
225
265
11.40
17.30
3X185+95
0.164
0.0991
0.197
0.1189
0.074
0.64
235
200
240
300
255
305
14.10
21.30
3X240+120
0.125
0.0754
0.151
0.0912
0.073
0.67
275
235
280
345
295
355
18.20
27.60
3X300+150
0.100
0.0601
0.122
0.0733
0.073
0.68
305
260
315
385
335
400
22.80
34.50
3X400+185
0.0778
0.0470
0.0961
0.0580
0.072
0.70
335
290
375
425
360
435
30.40
46.00
3X500+240
0.0605
0.0366
0.0759
0.0459
0.072
0.70
370
320
425
470
390
520
38.00
57.50
3X630+300
0.0469
0.0283
0.0610
0.0368
0.072
0.70
405
350
480
555
470
675
47.90
72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

14

15

LT/HT Power & Control Cables

Table - 5

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Ref Specication : IS 1554 Part-1

Physical Parameters

LT/HT Power & Control Cables

Table - 6

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLES
Ref Specication : IS 1554 Part-1
Cable Code : AYFaY/YFaY, AYWaY/YWaY

Physical Parameters

Approx. Weight of Cable


Size
(Cross Sectional
Area)

Minimum No. of Strand in


Conductor
Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

Nominal Insulation
Thickness

Minimum
Inner Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

mm
1.00
1.00
1.00
1.00
1.20
1.20
1.40
1.40
1.60
1.60
1.80
2.00
2.20
2.40
2.60
3.00
3.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.60
0.70
0.70
0.70
0.70

mm
1.80
1.80
1.80
2.00
2.00
2.00
2.20
2.20
2.40
2.40
2.60
2.80
3.00
3.40
3.60
4.00
4.00

mm
16
18
20
21
24
26
30
33
38
41
45
50
57
63
71
80
90

With Al'm Cond.

With Cu Cond.

AYY
Kg/Km
300
400
500
580
800
920
1250
1550
2050
2400
2950
3600
4600
5700
7100
9000
11300

YY
Kg/Km
430
540
750
950
1400
1750
2350
3150
4300
5250
6450
8000
10350
12900
16300
20900
26600

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

2
3
4

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.87
0.083
0.42
0.868
0.524
1.04
0.63
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.0759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

Nominal
Insulation
Thickness
mm
1.30
1.30
1.30
1.30
1.50
1.50
1.70
1.70
1.90
1.90
2.10
2.30
2.50
2.70
3.00
3.40
3.90
3.90
3.90

Flat Strip Armoured (AYFaY/YFaY)


Approx. Weight of Cable
Nominal
Minimum
Approx. With Al'm
With Cu
Armour
Outer
Overall Dia
Cond.
Cond.
Strip
Sheath
of Cable
Dimension Thickness
AYFaY
YFaY
mm
mm
mm
Kg/Km
Kg/Km
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4 x 0.80
1.40
21
650
1200
4 x 0.80
1.40
22
750
1450
4 x 0.80
1.40
24
850
1750
4 x 0.80
1.40
26
1000
2100
4 x 0.80
1.40
29
1250
2700
4 x 0.80
1.56
32
1550
3350
4 x 0.80
1.56
36
1900
4200
4 x 0.80
1.56
40
2350
5300
4 x 0.80
1.72
45
3000
6800
4 x 0.80
1.88
49
3600
8500
4 x 0.80
2.04
52
4300
10500

Nominal
Dia of
Armor
Wire
mm
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.50

Round Wire Armoured (AYWaY/YWaY)


Approx. Weight of Cable
Minimum
Approx. With Al'm
With Cu
Outer
Overall Dia
Cond.
Cond.
Sheath
of Cable
Thickness
AYWaY
YWaY
mm
mm
Kg/Km
Kg/Km
1.24
11
180
200
1.24
12
200
230
1.24
13
230
300
1.24
13
250
350
1.24
15
300
450
1.24
16
350
560
1.24
17
450
700
1.40
19
550
950
1.40
22
700
1250
1.40
24
800
1500
1.40
25
950
1800
1.40
27
1100
2200
1.56
30
1400
2800
1.56
33
1600
3400
1.56
38
2100
4400
1.72
42
2600
5600
1.88
47
3250
7050
1.88
51
3850
8750
2.04
55
4750
10900

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Minimum No. of
Strand in Conductor

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1

Size
(Cross
Sectional
Area)

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
28
23
23
36
30
30
35
30
30
45
38
39
46
39
40
60
50
52
60
50
51
77
64
66
76
63
70
99
81
90
92
77
86
120
99
110
110
95
105
145
125
135
135
115
130
175
150
165
165
140
155
210
175
200
185
155
180
240
195
230
210
175
205
270
225
265
235
200
240
300
255
305
275
235
280
345
295
355
305
260
315
385
335
400
335
290
375
425
360
435
370
320
425
470
390
520
405
350
480
555
470
675

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.157
0.48
4.61
3.08
5.53
3.70
0.148
0.56
3.08
1.83
3.70
2.20
0.138
0.67
1.91
1.15
2.29
1.38
0.128
0.81
1.20
0.727
1.44
0.87
0.120
0.87
0.868
0.524
1.04
0.63
0.114
1.00
0.641
0.387
0.769
0.464
0.110
1.03
0.443
0.268
0.532
0.322
0.103
1.21
0.320
0.193
0.384
0.232
0.101
1.27
0.253
0.153
0.304
0.184
0.096
1.42
0.206
0.1240
0.247
0.1488
0.094
1.42
0.164
0.0991
0.197
0.1189
0.092
1.44
0.125
0.0754
0.151
0.0912
0.090
1.53
0.100
0.0601
0.122
0.0733
0.088
1.56
0.0778
0.0470
0.0961
0.0580
0.088
1.59
0.0605
0.0366
0.076
0.0459
0.087
1.67
0.0469
0.0283
0.0610
0.0368
0.086
1.67
0.0367
0.0221
0.0503
0.0303
0.083
1.75
0.0291
0.0176
0.0422
0.0255
0.082
1.94

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
31
30
27
39
38
35
39
37
35
49
48
44
51
51
47
65
64
60
66
65
64
85
83
82
86
84
84
110
110
110
100
100
105
130
125
130
120
115
130
155
150
165
140
135
155
190
175
205
175
155
190
220
200
245
195
170
220
250
220
280
220
190
250
280
245
320
240
210
290
305
260
370
270
225
335
345
285
425
295
245
380
375
310
475
325
275
435
400
335
550
345
295
480
425
355
590
390
320
550
470
375
660
450
380
610
530
423
725
500
414
680
590
471
870

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.88
72.50
60.80
92.00
76.00
115.00

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

16

17

LT/HT Power & Control Cables

Table - 7

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


TWO CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE

LT/HT Power & Control Cables

Table - 8

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE

Ref Specication : IS 1554 Part-1

Physical Parameters

Cable Code : AYFY/YFY, AYWY/YWY


Flat Strip Armoured (AYFY/YFY)
Approx. Weight of Cable

Minimum No. of
Size
Nominal Minimum
Minimum Approx.
Nominal
(Cross Strand in Conductor Insulation
Inner
Outer
Overall
Armour Strip
Sectional
Thickness Sheath
Sheath
Dia of
Dimension
Thickness
Area) Aluminium Copper
Thickness Cable
Sqmm
No's
No's
mm
mm
mm
mm
mm
4
1/3
1/3
1.00
0.30
N/A
N/A
N/A
6
1/3
1/3
1.00
0.30
N/A
N/A
N/A
10
1/7
6
1.00
0.30
N/A
N/A
N/A
16
6
6
1.00
0.30
4 x 0.80
1.40
19
25
6
6
1.20
0.30
4 x 0.80
1.40
20
35
6
6
1.20
0.30
4 x 0.80
1.40
21
50
6
6
1.40
0.30
4 x 0.80
1.40
24
70
12
12
1.40
0.30
4 x 0.80
1.56
27
95
15
15
1.60
0.40
4 x 0.80
1.56
30
120
15
18
1.60
0.40
4 x 0.80
1.56
32
150
15
18
1.80
0.40
4 x 0.80
1.72
35
185
30
30
2.00
0.50
4 x 0.80
1.88
38
240
30
34
2.20
0.50
4 x 0.80
2.04
43
300
30
34
2.40
0.60
4 x 0.80
2.20
46
400
53
53
2.60
0.70
4 x 0.80
2.36
52
500
53
53
3.00
0.70
4 x 0.80
2.68
59
630
53
53
3.40
0.70
4 x 0.80
2.84
65

With Al'm
Cond.

With Cu
Cond.

AYFY
Kg/Km
N/A
N/A
N/A
550
680
780
950
1150
1450
1700
1950
2350
2900
3500
4300
5350
6650

YFY
Kg/Km
N/A
N/A
N/A
720
950
1200
1500
1950
2600
3100
3700
4550
5800
7100
8900
11300
14300

Round Wire Armoured (AYWaY/YWaY)


Approx. Weight of Cable

Nominal Minimum Approx.


Dia of
Outer
Overall
Armor
Sheath
Dia of
Wire Thickness Cable
mm
1.40
1.40
1.40
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.50
2.50
3.15
3.15
4.00

mm
1.24
1.24
1.24
1.40
1.40
1.40
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.20
2.52
2.84
3.00

mm
17
18
19
19
21
23
26
28
32
35
37
40
46
50
57
63
72

With Al'm
Cond.

With Cu
Cond.

AYWY
Kg/Km
500
580
700
700
900
1000
1250
1450
1950
2250
2550
3000
4000
4650
6150
7450
9850

YWY
Kg/Km
560
650
800
900
1200
1400
1800
2250
3100
3650
4300
5200
6850
8250
10800
13400
17500

Ref Specication : IS 1554 Part-1

Physical Parameters

Cable Code : AYFY/YFY, AYWY/YWY


Flat Strip Armoured (AYFY/YFY)
Approx. Weight of Cable

Size
Nominal Minimum Nominal Minimum Approx.
Minimum No. of
(Cross Strand in Conductor Insulation
Inner
Armour
Outer
Overall
Sectional
Thickness Sheath
Strip
Sheath
Dia of
Thickness Dimension Thickness Cable
Area) Aluminium Copper
Sqmm
No's
No's
mm
mm
mm
mm
mm
4
1/3
1/3
1.00
0.30
N/A
N/A
N/A
6
1/3
1/3
1.00
0.30
N/A
N/A
N/A
10
1/7
6
1.00
0.30
N/A
N/A
N/A
16
6
6
1.00
0.30
4 x 0.80
1.40
20
25
6
6
1.20
0.30
4 x 0.80
1.40
22
35
6
6
1.20
0.30
4 x 0.80
1.40
24
50
6
6
1.40
0.30
4 x 0.80
1.56
27
70
12
12
1.40
0.40
4 x 0.80
1.56
31
95
15
15
1.60
040
4 x 0.80
1.56
34
120
15
18
1.60
0.40
4 x 0.80
1.72
37
150
15
18
1.80
0.50
4 x 0.80
1.88
41
185
30
30
2.00
0.50
4 x 0.80
1.88
45
240
30
34
2.20
0.60
4 x 0.80
2.20
51
300
30
34
2.40
0.60
4 x 0.80
2.36
56
400
53
53
2.60
0.70
4 x 0.80
2.52
63
500
53
53
3.00
0.70
4 x 0.80
2.84
70
630
53
53
3.40
0.70
4 x 0.80
3.00
78

With Al'm
Cond.

With Cu
Cond.

AYFY
Kg/Km
N/A
N/A
N/A
650
850
980
1250
1550
1900
2250
2700
3200
4050
4900
6000
7600
9400

YFY
Kg/Km
N/A
N/A
N/A
950
1300
1600
2100
2750
3600
4400
5350
6500
8400
10300
13000
16500
20900

Nominal
Dia of
Armor
Wire
mm
1.40
1.40
1.40
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.50
2.50
2.50
3.15
3.15
4.00

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Cross-sectional view

2
3
4
5

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm
and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.870
0.083
0.42
0.868
0.524
1.04
0.630
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.0759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
32
27
27
41
35
35
40
34
35
50
44
45
55
45
47
70
58
60
70
58
59
90
75
78
90
76
78
115
97
105
110
92
99
140
120
125
135
115
125
165
145
155
160
140
150
205
180
195
190
170
185
240
215
230
210
190
210
275
235
265
240
210
240
310
270
305
275
240
275
350
300
350
320
275
325
405
345
410
355
305
365
450
385
465
385
345
420
490
485
530
425
380
475
540
460
605
465
415
540
640
550
785

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.150
1.22
1.840
1.90
2.880
2.66
4.030
3.80
5.750
5.32
8.050
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

18

2
3
4
5

mm
1.24
1.24
1.40
1.40
1.40
1.40
1.56
1.56
1.72
1.72
1.88
2.04
2.20
2.36
2.68
3.00
3.00

mm
17
18
21
22
24
26
29
33
37
40
43
48
54
59
67
75
85

Kg/Km
600
620
700
900
1100
1250
1550
2050
2550
2850
3400
4400
5300
6250
8300
10100
13300

Kg/Km
580
700
880
1150
1550
1850
2400
3250
4200
5000
6000
7700
9600
11700
15200
19000
24800

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm
and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow & Blue
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Round Wire Armoured (AYWaY/YWaY)


Approx. Weight of Cable
Minimum Approx.
Outer
Overall With Al'm With Cu
Cond.
Cond.
Sheath
Dia of
Thickness
Cable
AYWY
YWY

Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.87
0.083
0.42
0.868
0.524
1.04
0.63
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.0759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
28
23
23
36
30
30
35
30
30
45
38
39
46
39
40
60
50
52
60
50
51
77
64
66
76
63
70
99
81
90
92
77
86
120
99
110
110
95
105
145
125
135
135
115
130
175
150
165
165
140
155
210
175
200
185
155
180
240
195
230
210
175
205
270
225
265
235
200
240
300
255
305
275
235
280
345
295
355
305
260
315
385
335
400
335
290
375
425
360
435
370
320
425
470
390
520
405
350
480
555
470
675

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

19

LT/HT Power & Control Cables

Table - 9

LT/HT Power & Control Cables

Table - 10

TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLES

Ref Specication : IS 1554 Part-1

Physical Parameters
Size
(Cross
Sectional
Area)

Cable Code : AYFY/YFY, AYWY/YWY

Flat Strip Armoured (AYFY/YFY)


Round Wire Armoured (AYWaY/YWaY)
Minimum No. of
Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Nominal Minimum Approx. Approx. Weight of Cable
Strand in Conductor Insulation
With Cu
Inner
Armour
Outer
Overall With Al'm
Dia of
Outer
Overall With Al'm With Cu
Cond.
Cond.
Cond.
Cond.
Thickness Sheath
Strip
Sheath Dia of
Armor
Sheath
Dia of
Thickness Dimension Thickness Cable
Wire Thickness Cable
Aluminium Copper
AYFY
YFY
AYWY
YWY

Sqmm
3X25+16
3X35+16
3X50+25
3X70+35
3X95+50
3X120+70
3X150+70
3X185+95
3X240+120
3X300+150
3X400+185
3X500+240
3X630+300

No's
6/6
6/6
6/6
12/6
15/6
15/12
15/12
30/15
30/15
30/15
53/30
53/30
53/30

No's
6/6
6/6
6/6
12/6
15/6
18/12
18/12
30/15
34/18
34/18
53/30
53/34
53/34

mm
1.20/1.00
1.20/1.00
1.40/1.20
1.40/1.20
1.60/1.40
1.60/1.40
1.80/1.40
2.00/1.60
2.20/1.60
2.40/1.80
2.60/2.00
3.00/2.20
3.40/2.40

mm
0.30
0.30
0.30
0.40
0.40
0.50
0.50
0.50
0.60
0.60
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.56
1.56
1.56
1.72
1.88
2.04
2.20
2.36
2.68
2.84
3.00

mm
24
26
29
33
37
41
44
49
55
61
69
77
87

Kg/Km
1000
1100
1400
1750
2200
2650
3050
3700
4650
5550
6950
8700
10800

Kg/Km
1500
1850
2400
3150
4150
5150
6100
7600
9650
11900
15100
19100
24200

mm
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.50
2.50
3.15
3.15
4.00
4.00

mm
1.40
1.40
1.56
1.56
1.72
1.88
1.88
2.04
2.36
2.52
2.68
3.00
3.00

mm
25
28
32
35
40
43
47
52
59
66
73
84
93

Kg/Km
1200
1400
1900
2300
2850
3350
3800
4950
6050
7800
9400
12500
15000

Kg/Km
1750
2100
2900
3700
4850
5900
6850
8800
11100
14150
17500
22850
28400

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size
(Cross
Sectional Area)
Sqmm
3X25+16
3X35+16
3X50+25
3X70+35
3X95+50
3X120+70
3X150+70
3X185+95
3X240+120
3X300+150
3X400+185
3X500+240
3X630+300

Short Circuit Current


Normal Current Rating
Max. Conductor
Approx. Conductor
Reactance of Capacitance
Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable For Aluminium Conductor For Copper Conductor
Duration
Hz (Approx.)
(Approx.)
Aluminium Copper Aluminium Copper
Ground Duct
Air
Ground Duct
Air
Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps K.amps K.amps
1.20
0.727
1.44
0.87
0.083
0.42
76
63
70
99
81
90
1.90
2.88
0.868
0.524
1.04
0.63
0.082
0.48
92
77
86
120
99
110
2.66
4.03
0.641
0.387
0.769
0.464
0.082
0.49
110
95
105
145
125
135
3.80
5.75
0.443
0.268
0.532
0.322
0.076
0.56
135
115
130
175
150
165
5.32
8.05
0.320
0.193
0.384
0.232
0.076
0.58
165
140
155
210
175
200
7.22
10.90
0.253
0.153
0.304
0.184
0.075
0.63
185
155
180
240
195
230
9.12
13.80
0.206
0.1240
0.247
0.1488
0.074
0.63
210
175
205
270
225
265
11.40
17.30
0.164
0.0991
0.197
0.1189
0.074
0.64
235
200
240
300
255
305
14.10
21.30
0.125
0.0754
0.151
0.0912
0.073
0.67
275
235
280
345
295
355
18.20
27.60
0.100
0.0601
0.122
0.0733
0.073
0.68
305
260
315
385
335
400
22.80
34.50
0.0778
0.0470
0.0961
0.0580
0.072
0.70
335
290
375
425
360
435
30.40
46.00
0.0605
0.0366
0.0759
0.0459
0.072
0.70
370
320
425
470
390
520
38.00
57.50
0.0469
0.0283
0.0610
0.0368
0.072
0.70
405
350
480
555
470
675
47.90
72.50

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Ref Specication : IS 1554 Part-1


Cable Code : AYFY/YFY, AYWY/YWY

Physical Parameters
Flat Strip Armoured (AYFY/YFY)
Approx. Weight of Cable

Minimum No. of
Size
Nominal Minimum Nominal Minimum Approx.
(Cross Strand in Conductor Insulation
Inner
Armour
Outer
Overall
Sectional
Thickness Sheath
Strip
Sheath
Dia of
Thickness Dimension Thickness Cable
Area) Aluminium Copper
Sqmm
No's
No's
mm
mm
mm
mm
mm
4
1/3
1/3
1.00
0.30
N/A
N/A
N/A
6
1/3
1/3
1.00
0.30
N/A
N/A
N/A
10
1/7
6
1.00
0.30
4 x 0.80
1.40
21
16
6
6
1.00
0.30
4 x 0.80
1.40
22
25
6
6
1.20
0.30
4 x 0.80
1.40
25
35
6
6
1.20
0.30
4 x 0.80
1.40
27
50
6
6
1.40
0.40
4 x 0.80
1.56
30
70
12
12
1.40
0.40
4 x 0.80
1.56
34
95
15
15
1.60
0.40
4 x 0.80
1.72
39
120
15
18
1.60
0.50
4 x 0.80
1.88
42
150
15
18
1.80
0.50
4 x 0.80
1.88
46
185
30
30
2.00
0.60
4 x 0.80
2.04
51
240
30
34
2.20
0.60
4 x 0.80
2.36
57
300
30
34
2.40
0.70
4 x 0.80
2.52
64
400
53
53
2.60
0.70
4 x 0.80
2.84
72
500
53
53
3.00
0.70
4 x 0.80
3.00
80
630
53
53
3.40
0.70
4 x 0.80
3.00
90

With Al'm
Cond.

With Cu
Cond.

AYFY
Kg/Km
N/A
N/A
700
800
1000
1200
1500
1900
2450
2850
3350
4100
5100
6250
7800
9700
12100

YFY
Kg/Km
N/A
N/A
900
1200
1600
2050
2650
3500
4700
5700
6900
8500
10900
13500
17000
21600
27400

Round Wire Armoured (AYWaY/YWaY)


Approx. Weight of Cable
Approx.
Overall With Al'm With Cu
Cond.
Cond.
Dia of
Cable
AYWY
YWY

Nominal Minimum
Dia of
Outer
Armor
Sheath
Wire Thickness
mm
1.40
1.40
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.5
2.5
2.50
3.15
3.15
4.00
4.00

mm
1.24
1.24
1.40
1.40
1.40
1.56
1.56
1.56
1.72
1.88
2.04
2.20
2.36
2.68
2.84
3.00
3.00

mm
18
20
22
23
26
29
33
36
41
44
50
54
61
68
76
86
96

Kg/Km
650
660
880
1000
1250
1500
2050
2450
3050
3550
4550
5400
6600
8500
10300
13700
16500

Kg/Km
680
800
1150
1400
1850
2350
3150
4050
5300
6400
8050
9800
12400
15800
19600
25500
31800

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Max. Conductor
Approx. Conductor
Reactance of Capacitance
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50
of Cable
Hz (Approx.)
(Approx.)
Aluminium
Copper Aluminium Copper
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
7.41
4.61
8.89
5.53
0.098
0.23
4.61
3.08
5.53
3.70
0.096
0.28
3.08
1.83
3.70
2.20
0.091
0.34
1.91
1.15
2.29
1.38
0.085
0.40
1.20
0.727
1.44
0.87
0.083
0.42
0.868
0.524
1.04
0.63
0.082
0.48
0.641
0.387
0.769
0.464
0.082
0.49
0.443
0.268
0.532
0.322
0.076
0.56
0.320
0.193
0.384
0.232
0.076
0.58
0.253
0.153
0.304
0.184
0.075
0.63
0.206
0.1240
0.247
0.1488
0.074
0.63
0.164
0.0991
0.197
0.1189
0.074
0.64
0.125
0.0754
0.151
0.0912
0.073
0.67
0.100
0.0601
0.122
0.0733
0.073
0.68
0.0778
0.0470
0.0961
0.0580
0.072
0.70
0.0605
0.0366
0.0759
0.0459
0.072
0.70
0.0469
0.0283
0.0610
0.0368
0.072
0.70

Normal Current Rating


For Aluminium Conductor

For Copper Conductor

Ground Duct
Air
Ground Duct
Air
Amps Amps Amps Amps Amps Amps
28
23
23
36
30
30
35
30
30
45
38
39
46
39
40
60
50
52
60
50
51
77
64
66
76
63
70
99
81
90
92
77
86
120
99
110
110
95
105
145
125
135
135
115
130
175
150
165
165
140
155
210
175
200
185
155
180
240
195
230
210
175
205
270
225
265
235
200
240
300
255
305
275
235
280
345
295
355
305
260
315
385
335
400
335
290
375
425
360
435
370
320
425
470
390
520
405
350
480
555
470
675

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
Copper
K.amps
K.amps
0.304
0.460
0.456
0.690
0.760
1.15
1.22
1.84
1.90
2.88
2.66
4.03
3.80
5.75
5.32
8.05
7.22
10.90
9.12
13.80
11.40
17.30
14.10
21.30
18.20
27.60
22.80
34.50
30.40
46.00
38.00
57.50
47.90
72.50

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

20

21

LT/HT Power & Control Cables

Table - 11

TECHNICAL DETAILS FOR HAVELLS 1.1 KV 1.5 SQMM


COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref Specication : IS 1554 Part-1

Physical Parameters

Cable Code : YY/YFY/YWY


Unarmoured (YY)

No.
of
Cores

Nos
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Flat Strip Armoured (YFY)

Minimum Nominal
Approx.
Approx.
Inner
Outer Overall Dia of
Weight of Cable
Sheath
Cable
Sheath
Thickness Thickness Solid Std.
Soild
Std.
Cond. cond. Cond
cond.
mm
mm
mm mm Kg/Km Kg/Km
0.30
1.80
11
12
160
170
0.30
1.80
12
12
190
200
0.30
1.80
12
13
220
230
0.30
1.80
13
14
240
230
0.30
1.80
14
15
270
280
0.30
1.80
14
15
290
300
0.30
1.80
17
18
410
430
0.30
1.80
18
19
450
470
0.30
1.80
19
19
500
520
0.30
1.80
19
20
570
570
0.30
2.00
21
22
670
700
0.30
2.00
24
25
820
870
0.30
2.00
24
25
880
950
0.30
2.00
25
26
950
1000
0.30
2.00
27
28
1150
1200
0.30
2.00
28
29
1220
1270
0.30
2.00
30
31
1350
1400
0.40
2.00
31
33
1600
1650
0.40
2.20
34
35
1800
1900

Dimension of
Armour
Strip
mm
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

Minimum
Outer
Sheath
Thickness
mm
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56

LT/HT Power & Control Cables

Table - 12

TECHNICAL DETAILS FOR HAVELLS 1.1 KV 2.5 SQMM


COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES

Round Wire Armoured (YWY)

Approx. Weight of Nominal Minimum


Approx.
Approx. Weight of
Approx.
Cable
Overall Dia of
Cable
Dia of
Outer Overall Dia of
Cable
Cable
Armour Sheath
Wire
Thick- Soild Std.
Soild Std.
Soild
Std.
Soild
Std.
ness
Cond cond. Cond
cond.
Cond cond. Cond
cond.
mm mm Kg/Km Kg/Km mm
mm
mm mm Kg/Km Kg/Km
N/A N/A
N/A
N/A
1.40
1.24
13
13
350
370
N/A N/A
N/A
N/A
1.40
1.24
13
14
360
380
N/A N/A
N/A
N/A
1.40
1.24
14
15
410
430
N/A N/A
N/A
N/A
1.40
1.24
15
16
470
490
N/A N/A
N/A
N/A
1.40
1.24
16
17
530
550
N/A N/A
N/A
N/A
1.40
1.24
16
17
540
560
N/A N/A
N/A
N/A
1.40
1.40
19
20
720
760
18
19
620
640
1.60
1.40
20
21
830
860
20
20
700
740
1.60
1.40
21
22
900
950
20
21
780
800
1.60
1.40
22
23
1010
1030
21
22
850
900
1.60
1.40
23
24
1070
1130
24
26
1050
1110
1.60
1.40
26
27
1310
1370
25
26
1130
1190
1.60
1.40
26
28
1380
1450
26
27
1200
1270
1.60
1.40
27
28
1470
1540
27
29
1400
1470
1.60
1.40
29
30
1690
1770
29
30
1500
1570
1.60
1.56
31
32
1830
1910
31
32
1670
1760
1.60
1.56
33
34
2000
2100
32
34
1890
1980
2.00
1.56
35
36
2440
2550
34
36
2130
2250
2.00
1.56
37
38
2700
2830

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Unarmoured (YY)
No.
of
Cores

Nos
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Cross-sectional view

Electrical Parameters

No's
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Ohm/Km
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10

Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Nominal Insulation Thickness : 0.90 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on
cores as per IS : 1554 Part-1
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Normal Current Rating

Approx. Conductor
A.C.Resistance
at 85 C

Reactance
Capacitance
For General Purpose
of Cable
of Cable
Insulation
at 50 Hz
(Approx.)
(Approx.)
Ground Duct
Air

Ohm/Km Ohm/Km Ohm/Km


14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112
14.52
15.20
0.112

F/Km
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20

Amps
23
21
21
21
15
14
13
12
11
11
10
9
9
9
8
8
7
6
6

Amps Amps
20
20
17
17
17
17
17
17
13
13
13
13
11
11
10
10
10
10
9
9
9
9
8
8
8
8
7
7
7
7
7
7
7
7
6
6
6
6

For Heat Resisting


Insulation
Ground
Amps
26
24
24
24
17
16
15
14
13
13
11
10
10
10
9
9
8
7
7

Short Circuit Current Rating for 1 Second


Duration

For General Purpose


Insulation
Amps Amps
K.amps
24
24
0.173
21
21
0.173
21
21
0.173
21
21
0.173
16
16
0.173
15
15
0.173
13
13
0.173
12
12
0.173
12
12
0.173
11
11
0.173
11
11
0.173
10
10
0.173
10
10
0.173
8
8
0.173
8
8
0.173
8
8
0.173
7
7
0.173
7
7
0.173
7
7
0.173
Duct

Air

For Heat Resisting


Insulation
K.amps
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156
0.156

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

22

Round Wire Armoured (YWY)

Approx. Weight of Nominal Minimum


Approx.
Approx. Weight of
Minimum Nominal
Approx.
Approx.
Minimum
Approx. Weight of DimenCable
Cable
Inner
Dia of
Outer Overall Dia of
Outer Overall Dia of
Outer Overall Dia of
Cable
sion of
Cable
Cable
Sheath
Cable
Armour Sheath
Sheath
Sheath
Armour
Thickness Thickness Solid Std.
Wire
Thick- Soild Std.
Thick- Soild Std.
Soild
Std.
Soild
Std.
Soild
Std.
Strip
ness
ness
Cond. cond. Cond
cond.
Cond cond. Cond
cond.
Cond cond. Cond
cond.
mm
mm
mm mm Kg/Km Kg/Km mm
mm
mm mm Kg/Km Kg/Km mm
mm
mm mm Kg/Km Kg/Km
0.30
1.80
13
13
220
230
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
14
15
480
440
0.30
1.80
14
14
260
270
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
15
16
530
460
0.30
1.80
15
15
310
320
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
16
17
600
530
0.30
1.80
16
16
340
350
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
17
18
640
600
0.30
1.80
17
17
390
420
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
19
19
730
670
0.30
1.80
17
17
424
440
N/A
N/A
N/A N/A
N/A
N/A
1.40
1.24
19
19
760
700
0.30
1.80
20
21
570
660 4 x 0.80 1.40
21
22
850
900
1.60
1.40
23
24
1100
1030
0.30
2.00
21
22
670
750 4 x 0.80 1.40
22
23
950
1000
1.60
1.40
24
25
1180
1250
0.30
2.00
22
23
750
840 4 x 0.80 1.40
23
24
1050
1035
1.60
1.40
25
26
1300
1350
0.30
2.00
24
24
840
930 4 x 0.80 1.40
24
25
1120
1150
1.60
1.40
26
27
1400
1450
0.30
2.00
25
25
950
1050 4 x 0.80 1.40
25
26
1250
1330
1.60
1.40
27
28
1550
1620
0.30
2.00
28
29
1200
1380 4 x 0.80 1.40
29
30
1550
1630
1.60
1.56
31
32
1900
2000
0.30
2.00
29
30
1300
1470 4 x 0.80 1.40
30
31
1650
1750
1.60
1.56
32
33
2050
2100
0.30
2.00
30
31
1400
1590 4 x 0.80 1.56
31
32
1800
1920
1.60
1.56
33
34
2200
2250
0.40
2.20
33
34
1700
1900 4 x 0.80 1.56
34
35
2100
2225
2.00
1.56
36
37
2800
2900
0.40
2.20
34
36
1850
1900 4 x 0.80 1.56
35
36
2300
2400
2.00
1.56
37
39
2950
3100
0.40
2.20
36
38
2000
2100 4 x 0.80 1.56
37
37
2500
2600
2.00
1.56
40
41
3200
3350
0.40
2.20
38
40
2350
2450 4 x 0.80 1.56
39
41
2850
2950
2.00
1.72
42
43
3600
3700
0.40
2.20
40
43
2700
2800 4 x 0.80 1.56
41
43
3250
3350
2.00
1.72
44
46
4000
4200

Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Nominal Insulation Thickness : 0.80 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 1554 Part-1
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

at 70 C

Flat Strip Armoured (YFY)

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Max.
No.
Conductor
of
D.C.Resistance
Cores
at 20 C

Ref. Spec. : IS :1554PART -1


Cable Code : YY/YFY/YWY

Physical Parameters

Max.
No.
Conductor
of
D.C.Resistance
Cores
at 20 C
No's
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Ohm/Km
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41

Approx. Conductor
A.C.Resistance
at 70 C

at 85 C

Normal Current Rating


Reactance
Capacitance
For
General
Purpose
For Heat Resisting
of Cable
of Cable
Insulation
Insulation
at 50 Hz
(Approx.)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Ohm/Km Ohm/Km Ohm/Km


8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107
8.89
9.34
0.107

F/Km
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.220
0.22
0.22
0.22
0.22
0.22
0.22

Amps
32
27
27
27
21
20
18
17
16
15
14
13
12
12
11
11
10
9
8

Amps Amps
27
27
24
24
24
24
24
24
18
18
17
17
15
15
14
14
13
13
13
13
12
12
11
11
10
10
10
10
9
9
9
9
9
9
8
8
8
8

Amps
38
30
30
30
24
22
20
19
18
17
16
14
13
13
12
12
11
10
9

Short Circuit Current Rating for 1 Second


Duration

For General Purpose


Insulation
Amps Amps
K.amps
32
32
0.288
28
28
0.288
28
28
0.288
28
28
0.288
21
21
0.288
20
20
0.288
16
16
0.288
16
16
0.288
15
15
0.288
15
15
0.288
14
14
0.288
13
13
0.288
12
12
0.288
12
12
0.288
10
10
0.288
10
10
0.288
10
10
0.288
10
10
0.288
9
9
0.288

For Heat Resisting


Insulation
K.amps
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no.52 - 54

23

LT/HT Power & Control Cables

Table - 13

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XY/2XY

Physical Parameters
Minimum No. of Strand in
Conductor

Size
(Cross Sectional
Area)

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53

No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

Nominal Insulation
Thickness
mm
0.70
0.70
0.70
0.70
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40
2.60
2.80

Nominal Outer
Approx. Overall Dia of Cable
Sheath Thickness
mm
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.00
2.20
2.20
2.20
2.40
2.60

mm
9
10
11
10
12
13
14
16
18
20
22
24
26
29
33
36
41
45
49

Approx. Weight of Cable


With Al'm Cond.
A2XY
Kg/Km
110
120
150
150
190
230
280
370
450
550
660
800
1000
1200
1550
1900
2350
2950
3650

With Cu Cond.
2XY
Kg/Km
130
160
210
250
350
450
600
800
1050
1250
1550
1900
2450
3000
3800
4850
6150
7850
9800

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

LT/HT Power & Control Cables

Table - 14

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


TWO CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES

2
3

Aluminium

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

Copper

Nominal
Insulation
Thickness

Minimum Inner
Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

mm
0.70
0.70
0.70
0.70
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.60
0.70
0.70

mm
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.00
2.20
2.20
2.20
2.40
2.60
2.80
3.00
3.40
3.60

mm
13
14
16
15
18
20
22
24
27
30
32
35
40
43
49
54
60

Approx. Weight of Cable


With Al'm Cond.
A2XY
Kg/Km
200
260
330
300
420
500
600
780
1000
1200
1400
1750
2200
2700
3350
4250
5250

With Cu Cond.
2XY
Kg/Km
270
330
450
500
720
920
1200
1600
2150
2650
3150
3950
5100
6300
7950
10200
12950

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

2
3
4

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters
Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

K.amps
0.572
0.858
1.43
2.28
3.57
5.00
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09
114.40
143.00

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.136
4.61
3.08
5.90
3.94
0.128
3.08
1.83
3.94
2.34
0.118
1.91
1.15
2.44
1.47
0.108
1.20
0.727
1.54
0.931
0.102
0.868
0.524
1.11
0.671
0.097
0.641
0.387
0.820
0.495
0.092
0.443
0.268
0.567
0.343
0.088
0.320
0.193
0.411
0.248
0.085
0.253
0.153
0.325
0.197
0.082
0.206
0.1240
0.265
0.159
0.082
0.164
0.0991
0.211
0.127
0.082
0.125
0.0754
0.162
0.0976
0.079
0.100
0.0601
0.130
0.0778
0.078
0.0778
0.0470
0.1023
0.0618
0.077
0.0605
0.0366
0.0808
0.0489
0.076
0.0469
0.0283
0.0648
0.0391
0.075
0.0367
0.0221
0.0530
0.0319
0.075
0.0291
0.0176
0.0444
0.0268
0.068

Minimum No. of Strand in


Conductor

Size
(Cross Sectional
Area)

Cross-sectional view
1

Ref Specication : IS 7098 Part-1


Cable Code : A2XY/2XY

Physical Parameters

F/Km
0.29
0.34
0.42
0.50
0.52
0.60
0.63
0.68
0.79
0.79
0.79
0.79
0.84
0.86
0.88
0.90
0.94
0.97
1.01

Amps

48
62
81
99
117
138
168
204
230
265
295
340
390
450
500
555
625
690

Amps

45
62
80
90
110
125
155
185
210
230
260
300
335
380
430
485
530
570

Amps

45
61
83
115
135
170
210
255
300
342
385
450
519
605
700
809
935
1065

Amps
48
60
80
104
130
155
185
225
265
300
335
380
435
490
550
610
680
740
780

Amps
47
59
78
102
115
140
165
200
235
265
300
335
385
430
480
530
590
630
660

Amps
45
57
77
106
145
175
215
270
330
380
430
495
590
670
780
900
1020
1140
1250

Short Circuit Current


Rating for 1 Second
Duration

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
461
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

24

25

LT/HT Power & Control Cables

Table - 16

Table - 15

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XY/2XY

Physical Parameters
Minimum No. of Strand in
Conductor

Size
(Cross Sectional
Area)

Aluminium

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

LT/HT Power & Control Cables

Copper

Nominal
Insulation
Thickness

Minimum Inner
Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

mm
0.70
0.70
0.70
0.70
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.60
0.70
0.70
0.70

mm
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.20
2.20
2.20
2.40
2.60
2.80
3.00
3.20
3.60
3.80

mm
14
15
17
18
20
22
25
29
31
34
38
42
48
52
59
66
73

Approx. Weight of Cable


With Al'm Cond.
A2XY
Kg/Km
230
300
360
400
550
650
800
1100
1350
1650
2050
2500
3150
3850
4800
6050
7600

With Cu Cond.
2XY
Kg/Km
310
400
540
680
1000
1300
1650
2300
3050
3800
4650
5800
7500
9250
11800
15000
19100

TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES

Aluminium

Sqmm
3X25+16
3X35+16
3X50+25
3X70+35
3X95+50
3X120+70
3X150+70
3X185+95
3X240+120
3X300+150
3X400+185
3X500+240
3X630+300

No's
6/6
6/6
6/6
12/6
15/6
15/12
15/12
30/15
30/15
30/15
53/30
53/30
53/30

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

2
3
4

Electrical Parameters

Minimum Inner
Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

No's
6/6
6/6
6/6
12/6
15/6
18/12
18/12
30/15
34/18
34/18
53/30
53/34
53/34

mm
0.90/0.70
0.90/0.70
1.00/0.90
1.10/0.90
1.10/1.00
1.20/1.10
1.40/1.10
1.60/1.10
1.70/1.20
1.80/1.40
2.00/1.60
2.20/1.70
2.40/1.80

mm
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.60
0.60
0.70
0.70
0.70

mm
2.00
2.00
2.00
2.20
2.20
2.20
2.40
2.60
2.80
3.00
3.40
3.60
4.00

mm
22
24
26
31
34
37
42
46
52
57
65
72
82

Approx. Weight of Cable


With Al'm Cond.
A2XY
Kg/Km
620
750
920
1250
1550
1900
2300
2850
3600
4400
5600
6950
8800

With Cu Cond.
2XY
Kg/Km
1150
1450
1900
2650
3550
4450
5350
6700
8650
10700
13600
17400
22200

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

Copper

Nominal
Insulation
Thickness

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Minimum No. of Strand in


Conductor

Size
(Cross Sectional
Area)

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Ref Specication : IS 7098 Part-1


Cable Code : A2XY/2XY

Physical Parameters

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
461
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Max. Conductor
Approx. Conductor
Reactance
Normal Current Rating
Size
Capacitance
D.C.Resistance at 20 C A.C.Resistance at 90 C
of Cable
(Cross Sectional
of Cable
For Aluminium Conductor
For Copper Conductor
at 50 Hz
Area)
(Approx.)
Aluminium Copper Aluminium Copper
(Approx.)
Ground Duct
Air
Ground Duct
Air
Sqmm
3X25+16
3X35+16
3X50+25
3X70+35
3X95+50
3X120+70
3X150+70
3X185+95
3X240+120
3X300+150
3X400+185
3X500+240
3X630+300

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

F/Km
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps Amps
95
80
116
94
140
110
170
140
200
165
225
185
255
210
285
235
325
270
370
305
435
350
481
405
537
470

Amps
99
117
140
176
221
258
294
339
402
461
542
624
723

Amps Amps
120
100
145
120
170
145
210
175
250
210
285
240
315
270
355
300
410
350
460
390
520
440
580
480
680
575

Amps
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration
Aluminium

Copper

K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

26

27

LT/HT Power & Control Cables

Table - 17

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XY/2XY

Physical Parameters
Minimum No. of Strand in
Conductor

Size
(Cross Sectional
Area)

Aluminium

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53

Copper

Nominal
Insulation
Thickness

Minimum Inner
Sheath
Thickness

Nominal Outer
Sheath Thickness

Approx. Overall
Dia of Cable

No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53

mm
0.70
0.70
0.70
0.70
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.50
0.50
0.50
0.60
0.70
0.70
0.70
0.70

mm
1.80
1.80
1.80
1.80
2.00
2.00
2.00
2.20
2.20
2.40
2.60
2.80
3.00
3.20
3.60
3.80
4.00

mm
15
16
19
19
23
25
27
32
35
39
43
48
54
60
68
75
85

Approx. Weight of Cable


With Al'm Cond.
A2XY
Kg/Km
250
330
420
450
650
800
1000
1350
1700
2150
2600
3200
4100
5000
6300
7850
9850

With Cu Cond.
2XY
Kg/Km
370
470
660
850
1250
1650
2150
3000
4000
5000
6100
7600
9850
12200
15600
19700
25200

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY

Physical Parameters
Size
(Cross
Sectional
Area)
Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Minimum No. of
Strand in Conductor
Aluminium
No's
1/3
1/3
1/7
6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53

Copper
No's
1/3
1/3
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

Nominal
Insulation
Thickness
mm
1.00
1.00
1.00
1.00
1.20
1.20
1.30
1.40
1.40
1.50
1.70
1.90
2.00
2.10
2.40
2.60
2.80
3.10
3.30

Flat Strip Armoured (A2XFaY/2XFaY)


Approx. Weight of Cable
Minimum
Nominal
Approx. With Alm
With Cu
Armour
Outer
Overall Dia
Cond.
Cond.
Strip
Sheath
of Cable
Dimension Thickness
A2XFaY
2XFaY
mm
mm
mm
Kg/Km
Kg/Km
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4 x 0.80
1.40
20
550
1150
4 x 0.80
1.40
22
650
1400
4 x 0.80
1.40
23
760
1650
4 x 0.80
1.40
26
920
2050
4 x 0.80
1.40
28
1100
2550
4 x 0.80
1.56
31
1350
3200
4 x 0.80
1.56
35
1700
4000
4 x 0.80
1.56
38
2050
5000
4 x 0.80
1.72
42
2600
6400
4 x 0.80
1.72
47
3200
8100
4 x 0.80
1.88
51
3900
10100

Nominal
Dia of
Armor
Wire
mm
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.50

Round Wire Armoured (A2XWaY/2XWaY)


Approx. Weight of Cable
Minimum
Approx. With Al'm
With Cu
Outer
Overall Dia
Cond.
Cond.
Sheath
of Cable
Thickness
A2XWaY
2XWaY
mm
mm
Kg/Km
Kg/Km
1.24
11
150
180
1.24
11
180
220
1.24
12
200
270
1.24
13
220
320
1.24
14
280
450
1.24
15
350
550
1.24
17
400
680
1.24
19
500
900
1.40
21
620
1200
1.40
23
720
1450
1.40
25
850
1750
1.40
27
1000
2100
1.40
29
1200
2650
1.56
32
1450
3250
1.56
37
1850
4200
1.56
40
2250
5250
1.72
44
2800
6650
1.88
49
3500
8400
2.04
54
4400
10550

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
461
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

28

Table - 18

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

LT/HT Power & Control Cables

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

K.amps
0.376
0.56
0.94
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09
114.40
143.00

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.152
4.61
3.08
5.90
3.94
0.144
3.08
1.83
3.94
2.34
0.133
1.91
1.15
2.44
1.47
0.122
1.20
0.727
1.54
0.931
0.116
0.868
0.524
1.11
0.671
0.110
0.641
0.387
0.820
0.495
0.103
0.443
0.268
0.567
0.343
0.099
0.320
0.193
0.411
0.248
0.097
0.253
0.153
0.325
0.197
0.093
0.206
0.1240
0.265
0.159
0.091
0.164
0.0991
0.211
0.127
0.090
0.125
0.0754
0.162
0.0976
0.086
0.100
0.0601
0.130
0.0778
0.085
0.0778
0.0470
0.1023
0.0618
0.085
0.0605
0.0366
0.0808
0.0489
0.083
0.0469
0.0283
0.0648
0.0391
0.082
0.0367
0.0221
0.0530
0.0319
0.081
0.0291
0.0176
0.0444
0.0268
0.081

F/Km
0.22
0.26
0.31
0.40
0.40
0.47
0.50
0.55
0.64
0.67
0.67
0.67
0.72
0.75
0.75
0.77
0.81
0.88
0.88

Amps

45
59
76
99
117
138
168
204
230
265
295
340
390
450
500
555
625
690

Amps

45
62
80
90
110
125
155
185
210
230
260
300
335
380
430
485
530
570

Amps

40
53
73
115
140
170
210
255
300
342
385
450
519
605
700
809
935
1065

Amps
48
60
80
104
130
155
185
225
265
300
335
380
435
490
550
610
680
740
780

Amps
47
59
78
102
115
140
165
200
235
265
300
335
385
430
480
530
590
630
660

Amps
45
57
77
106
145
175
215
270
330
380
430
495
590
670
780
900
1020
1140
1250

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

29

LT/HT Power & Control Cables

Table - 19

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


TWO CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XFY/2XFY, A2XWY/2XWY

Physical Parameters

Flat Strip Armoured (A2XFY/2XFY)


Round Wire Armoured (A2XWY/2XWY)
Approx.
Weight
of
Cable
Approx. Weight of Cable
Size
Nominal Minimum Nominal Minimum Approx.
Minimum No. of
Nominal Minimum Approx.
With Cu
(Cross Strand in Conductor Insulation
Inner
Dia of
Outer
Overall With Al'm With Cu
Armour
Outer
Overall With Al'm
Cond.
Cond.
Cond.
Cond.
Sectional
Thickness Sheath
Dia of
Armor
Sheath
Dia of
Strip
Sheath
Area) Aluminium Copper
Thickness Dimension Thickness Cable
Wire
Thickness
Cable
A2XFY
2XFY
A2XWY
2XWY
Sqmm
No's
No's
mm
mm
mm
mm
mm
Kg/Km
Kg/Km
mm
mm
mm
Kg/Km
Kg/Km
4
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
15
500
480
6
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
16
500
580
10
1/7
6
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
18
600
730
16
6
6
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.40
17
600
750
25
6
6
0.90
0.30
4 x 0.80
1.40
18
650
950
1.60
1.40
20
800
1050
35
6
6
0.90
0.30
4 x 0.80
1.40
20
750
1200
1.60
1.40
22
900
1300
50
6
6
1.00
0.30
4 x 0.80
1.40
22
900
1500
1.60
1.40
24
1050
1650
70
12
12
1.10
0.30
4 x 0.80
1.56
25
1100
1950
1.60
1.56
27
1300
2100
95
15
15
1.10
0.40
4 x 0.80
1.56
28
1350
2500
2.00
1.56
30
1750
2900
120
15
18
1.20
0.40
4 x 0.80
1.56
30
1600
3100
2.00
1.56
33
2000
3400
150
15
18
1.40
0.40
4 x 0.80
1.72
33
1900
3750
2.00
1.72
35
2300
4050
185
30
30
1.60
0.50
4 x 0.80
1.72
36
2250
4500
2.00
1.88
39
2750
4900
240
30
34
1.70
0.50
4 x 0.80
1.88
41
2800
5800
2.50
2.04
44
3600
6500
300
30
34
1.80
0.60
4 x 0.80
2.04
44
3300
7000
2.50
2.20
47
4200
7800
400
53
53
2.00
0.60
4 x 0.80
2.36
49
4100
9050
2.50
2.36
53
5050
9700
500
53
53
2.20
0.70
4 x 0.80
2.52
55
5000
11000
3.15
2.68
59
6660
12700
630
53
53
2.40
0.70
4 x 0.80
2.68
60
6100
14000
3.15
2.84
65
7900
15700

LT/HT Power & Control Cables

Table - 20

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Cable Code : A2XFY/2XFY, A2XWY/2XWY

Physical Parameters

Flat Strip Armoured (A2XFY/2XFY)


Round Wire Armoured (A2XWY/2XWY)
Approx.
Weight
of
Cable
Approx. Weight of Cable
Size
Nominal Minimum Nominal Minimum Approx.
Minimum No. of
Nominal Minimum Approx.
With Cu
(Cross Strand in Conductor Insulation
Inner
Dia of
Outer
Overall With Al'm With Cu
Armour
Outer
Overall With Al'm
Cond.
Cond.
Cond.
Cond.
Sectional
Thickness Sheath
Dia of
Armor
Sheath
Dia of
Strip
Sheath
Area) Aluminium Copper
Thickness Dimension Thickness Cable
Wire
Thickness
Cable
A2XFY
2XFY
A2XWY
2XWY
Sqmm
No's
No's
mm
mm
mm
mm
mm
Kg/Km
Kg/Km
mm
mm
mm
Kg/Km
Kg/Km
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
16
600
520
4
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
17
500
600
6
10
1/7
6
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
19
600
780
4 x 0.80
1.24
18
600
880
1.60
1.40
20
780
1050
16
6
6
0.70
0.30
4 x 0.80
1.40
21
750
1200
1.60
1.40
22
950
1400
25
6
6
0.90
0.30
35
6
6
0.90
0.30
4 x 0.80
1.40
23
900
1500
1.60
1.40
24
1100
1750
4 x 0.80
1.40
26
1100
1900
1.60
1.56
27
1350
2200
50
6
6
1.00
0.30
70
12
12
1.10
0.40
4 x 0.80
1.56
29
1400
2600
2.00
1.56
32
1850
3100
4 x 0.80
1.56
32
1700
3350
2.00
1.56
34
2200
3900
95
15
15
1.10
0.40
4 x 0.80
1.56
35
2000
4100
2.00
1.72
38
2600
4750
120
15
18
1.20
0.40
150
15
18
1.40
0.50
4 x 0.80
1.72
39
2400
5050
2.00
1.88
41
3050
5700
4 x 0.80
1.88
43
2900
6200
2.50
2.04
47
4000
7300
185
30
30
1.60
0.50
4 x 0.80
2.04
48
3600
7900
2.50
2.20
52
4850
9150
240
30
34
1.70
0.60
4 x 0.80
2.20
53
4300
9750
2.50
2.36
56
5650
11100
300
30
34
1.80
0.60
4 x 0.80
2.52
60
5400
12400
3.15
2.68
64
7550
14500
400
53
53
2.00
0.70
500
53
53
2.20
0.70
4 x 0.80
2.68
66
6650
15600
3.15
2.84
71
9000
17900
4 x 0.80
2.84
74
8250
19800
4.00
3.00
80
12000
23400
630
53
53
2.40
0.70

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red,Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters
Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.1
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
461
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

30

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
460
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

31

LT/HT Power & Control Cables

Table - 21

Table - 22

TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

TECHNICAL DETAILS FOR HAVELLS 1.1 KV


FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

Ref Specication : IS 7098 Part-1


Cable Code : A2XFY/2XFY, A2XWY/2XWY

Physical Parameters
Size
(Cross
Sectional
Area)

LT/HT Power & Control Cables

Nominal
Insulation
Thickness

Minimum No. of
Strand in Conductor
Aluminium Copper

Flat Strip Armoured (A2XFY/2XFY)


Round Wire Armoured (A2XWY/2XWY)
Minimum
Approx. Weight of Cable
Minimum
Approx. Weight of Cable
Nominal
Approx.
Nominal Minimum Approx.
Inner
Outer
Overall With Al'm With Cu
Armour
Overall With Al'm With Cu
Dia of
Outer
Sheath
Sheath
Cond.
Cond.
Cond.
Cond.
Sheath Dia of
Strip
Dia of
Armor
ThickThickThickness
Cable
Dimension
Cable
Wire
A2XFY
2XFY
A2XWY
2XWY
ness
ness
mm
mm
mm
mm
Kg/Km
Kg/Km
mm
mm
mm
Kg/Km
Kg/Km

Sqmm

No's

No's

mm

3X25+16

6/6

6/6

0.90/0.70

0.30

4 x 0.80

1.40

22

850

1400

1.60

1.40

24

1050

1600

3X35+16

6/6

6/6

0.90/0.70

0.30

4 x 0.80

1.40

24

1000

1700

1.60

1.40

26

1200

1950

3X50+25

6/6

6/6

1.00/0.90

0.30

4 x 0.80

1.40

27

1200

2200

1.60

1.56

29

1500

2500

3X70+35

12/6

12/6

1.10/0.90

0.40

4 x 0.80

1.56

31

1550

2950

2.00

1.56

33

2050

3500

3X95+50

15/6

15/6

1.10/1.00

0.40

4 x 0.80

1.56

35

1900

3900

2.00

1.56

37

2500

4450

3X120+70

15/12

18/12

1.20/1.10

0.40

4 x 0.80

1.72

38

2300

4850

2.00

1.72

41

3000

5500

3X150+70

15/12

18/12

1.40/1.10

0.50

4 x 0.80

1.72

42

2700

5750

2.00

1.88

45

3450

6500

3X185+95

30/15

30/15

1.60/1.10

0.50

4 x 0.80

1.88

47

3300

7150

2.50

2.04

50

4500

8400

3X240+120

30/15

34/18

1.70/1.20

0.60

4 x 0.80

2.04

53

4100

9150

2.50

2.20

56

5450

10500

3X300+150

30/15

34/18

1.80/1.40

0.60

4 x 0.80

2.20

58

4900

11250

2.50

2.36

61

6400

12750

3X400+185

53/30

53/30

2.00/1.60

0.70

4 x 0.80

2.52

66

6150

14250

3.15

2.68

71

8550

16600

3X500+240

53/30

53/34

2.20/1.70

0.70

4 x 0.80

2.68

73

7600

18000

3.15

2.84

78

10250

20700

3X630+300

53/30

53/34

2.40/1.80

0.70

4 x 0.80

3.00

82

9500

22900

4.00

3.00

88

13500

26900

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Flat Strip Armoured (A2XFY/2XFY)


Round Wire Armoured (A2XWY/2XWY)
Approx.
Weight
of
Cable
Approx. Weight of Cable
Size
Nominal Minimum Nominal Minimum Approx.
Minimum No. of
Nominal Minimum Approx.
With Cu
(Cross Strand in Conductor Insulation
Inner
Dia of
Outer
Overall With Al'm With Cu
Armour
Outer
Overall With Al'm
Cond.
Cond.
Cond.
Cond.
Sectional
Thickness Sheath
Dia of
Armor
Sheath
Dia of
Strip
Sheath
Area) Aluminium Copper
Thickness Dimension Thickness Cable
Wire
Thickness
Cable
A2XFY
2XFY
A2XWY
2XWY
Sqmm
No's
No's
mm
mm
mm
mm
mm
Kg/Km
Kg/Km
mm
mm
mm
Kg/Km
Kg/Km
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
17
550
600
4
6
1/3
1/3
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.24
18
580
700
10
1/7
6
0.70
0.30
N/A
N/A
N/A
N/A
N/A
1.40
1.40
21
720
950
16
6
6
0.70
0.30
4 x 0.80
1.40
20
700
1100
1.60
1.40
22
900
1250
25
6
6
0.90
0.30
4 x 0.80
1.40
23
900
1500
1.60
1.40
25
1150
1700
35
6
6
0.90
0.30
4 x 0.80
1.40
25
1100
1900
1.60
1.40
27
1300
2150
50
6
6
1.00
0.30
4 x 0.80
1.56
28
1300
2400
1.60
1.56
30
1600
2750
70
12
12
1.10
0.40
4 x 0.80
1.56
32
1700
3300
2.00
1.56
34
2200
3850
95
15
15
1.10
0.40
4 x 0.80
1.56
36
2100
4350
2.00
1.72
38
2700
5000
120
15
18
1.20
0.50
4 x 0.80
1.72
40
2500
5350
2.00
1.88
42
3250
6100
150
15
18
1.40
0.50
4 x 0.80
1.88
44
3050
6550
2.50
2.04
47
4150
7700
185
30
30
1.60
0.50
4 x 0.80
2.04
49
3650
8050
2.50
2.20
52
4900
9300
240
30
34
1.70
0.60
4 x 0.80
2.20
55
4550
10400
2.50
2.36
58
6000
11800
300
30
34
1.80
0.70
4 x 0.80
2.36
60
5650
12800
3.15
2.52
65
7700
15000
400
53
53
2.00
0.70
4 x 0.80
2.68
69
6900
16200
3.15
2.84
73
9400
18600
500
53
53
2.20
0.70
4 x 0.80
2.84
76
8550
20400
4.00
3.00
82
12300
24200
630
53
53
2.40
0.70
4 x 0.80
3.00
85
10600
26000
4.00
3.00
91
14800
30100
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Cross-sectional view

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red,Yellow, Blue & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters

Size
(Cross
Sectional
Area)

Max. Conductor
Approx. Conductor
Reactance
Normal Current Rating
Capacitance
D.C.Resistance at 20 C A.C.Resistance at 90 C
of Cable
of Cable
For Aluminium Conductor
For Copper Conductor
at 50 Hz
(Approx.)
Aluminium Copper Aluminium Copper
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km

K.amps

K.amps

F/Km

Amps

Amps

Amps

Amps

Amps

Amps

Short Circuit Current


Rating for 1 Second
Duration

3X25+16

1.20

0.727

1.54

0.931

0.080

0.20

95

80

99

120

100

125

2.35

3.58

3X35+16

0.868

0.524

1.11

0.671

0.080

0.23

116

94

117

145

120

155

3.29

5.01

3X50+25

0.641

0.387

0.820

0.495

0.078

0.24

140

110

140

170

145

190

4.70

7.15

3X70+35

0.443

0.268

0.567

0.343

0.077

0.26

170

140

176

210

175

235

6.58

10.01

3X95+50

0.320

0.193

0.411

0.248

0.074

0.29

200

165

221

250

210

290

8.93

13.59

3X120+70

0.253

0.153

0.325

0.197

0.072

0.29

225

185

258

285

240

330

11.28

17.16

3X150+70

0.206

0.1240

0.265

0.159

0.072

0.29

255

210

294

315

270

375

14.10

21.45

3X185+95

0.164

0.0991

0.211

0.127

0.072

0.29

285

235

339

355

300

435

17.39

26.46

3X240+120

0.125

0.0754

0.162

0.0976

0.072

0.31

325

270

402

410

350

510

22.56

34.32

3X300+150

0.100

0.0601

0.130

0.0778

0.071

0.33

370

305

461

460

390

590

28.20

42.90

3X400+185

0.0778

0.0470

0.1023

0.0618

0.070

0.33

435

350

542

520

440

670

37.60

57.20

3X500+240

0.0605

0.0366

0.0808

0.0489

0.070

0.34

481

405

624

580

480

750

47.00

71.50

3X630+300

0.0469

0.0283

0.0648

0.0391

0.069

0.36

537

470

723

680

575

875

59.22

90.09

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

32

Ref Specication : IS 7098 Part-1


Cable Code : A2XFY/2XFY, A2XWY/2XWY

Physical Parameters

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

K.amps
0.376
0.564
0.940
1.50
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22

K.amps
0.572
0.858
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


7.41
4.61
9.48
5.90
0.098
4.61
3.08
5.90
3.94
0.090
3.08
1.83
3.94
2.34
0.084
1.91
1.15
2.44
1.47
0.080
1.20
0.727
1.54
0.931
0.080
0.868
0.524
1.11
0.671
0.080
0.641
0.387
0.820
0.495
0.078
0.443
0.268
0.567
0.343
0.077
0.320
0.193
0.411
0.248
0.074
0.253
0.153
0.325
0.197
0.072
0.206
0.1240
0.265
0.159
0.072
0.164
0.0991
0.211
0.127
0.072
0.125
0.0754
0.162
0.0976
0.072
0.100
0.0601
0.130
0.0778
0.071
0.0778
0.0470
0.1023
0.0618
0.070
0.0605
0.0366
0.0808
0.0489
0.070
0.0469
0.0283
0.0648
0.0391
0.069

F/Km
0.11
0.13
0.16
0.18
0.20
0.23
0.24
0.26
0.29
0.29
0.29
0.29
0.31
0.33
0.33
0.34
0.36

Amps
34
43
57
78
95
116
140
170
200
225
255
285
325
370
435
481
537

Amps
28
37
48
61
80
94
110
140
165
185
210
235
270
305
350
405
470

Amps
30
40
53
70
99
117
140
176
221
258
294
339
402
460
542
624
723

Amps
44
55
74
94
120
145
170
210
250
285
315
355
410
460
520
580
680

Amps
37
47
61
78
100
120
145
175
210
240
270
300
350
390
440
480
575

Amps
39
50
67
85
125
155
190
235
290
330
375
435
510
590
670
750
875

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

33

LT/HT Power & Control Cables

Table - 23

Table - 24

TECHNICAL DETAILS FOR HAVELLS 1.1 KV 1.5 SQMM


COPPER CONDUCTOR, XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref Specication : IS 7098 Part-1
Cable Code : 2XY/2XFY/2XWY

Physical Parameters
Unarmoured (2XY)
No.
of
Cores

Nos
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

LT/HT Power & Control Cables

Flat Strip Armoured (2XFY)

Minimum Nominal
Approx.
Approx.
Inner
Outer Overall Dia of
Weight of Cable
Sheath
Cable
Sheath
Thickness Thickness Solid Std.
Soild
Std.
Cond. cond. Cond
cond.
mm
mm
mm mm Kg/Km Kg/Km
0.30
1.80
11
11
160
170
0.30
1.80
11
12
180
190
0.30
1.80
12
12
210
220
0.30
1.80
13
13
240
260
0.30
1.80
14
14
280
300
0.30
1.80
14
14
280
300
0.30
1.80
16
17
420
450
0.30
1.80
17
18
450
470
0.30
1.80
18
18
490
520
0.30
1.80
18
19
550
580
0.30
1.80
19
20
610
640
0.30
2.00
23
24
830
880
0.30
2.00
23
24
870
920
0.30
2.00
24
25
940
990
0.30
2.00
25
27
1100
1150
0.30
2.00
26
28
1080
1240
0.30
2.00
28
30
1350
1430
0.30
2.00
30
31
1490
1570
0.40
2.20
32
34
1740
1830

Dimension of
Armour
Strip
mm
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

Minimum
Outer
Sheath
Thickness
mm
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56

TECHNICAL DETAILS FOR HAVELLS 1.1 KV 2.5 SQMM


COPPER CONDUCTOR, XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES

Round Wire Armoured (2XWY)

Approx.
Approx. Weight of
Approx.
Approx. Weight of Nominal Minimum
Cable
Overall Dia of
Cable
Outer Overall Dia of
Dia of
Cable
Cable
Armour Sheath
Wire
Thick- Soild Std.
Soild Std.
Soild
Std.
Soild
Std.
ness
Cond cond. Cond
cond.
Cond cond. Cond
cond.
mm mm Kg/Km Kg/Km mm
mm
mm mm Kg/Km Kg/Km
N/A N/A
N/A
N/A
1.40
1.24
13
13
330
350
N/A N/A
N/A
N/A
1.40
1.24
13
13
340
360
N/A N/A
N/A
N/A
1.40
1.24
14
14
390
400
N/A N/A
N/A
N/A
1.40
1.24
15
15
440
460
N/A N/A
N/A
N/A
1.40
1.24
15
16
490
520
N/A N/A
N/A
N/A
1.40
1.24
15
16
500
520
N/A N/A
N/A
N/A
1.40
1.24
18
19
660
680
N/A N/A
N/A
N/A
1.40
1.40
19
20
720
740
N/A N/A
N/A
N/A
1.40
1.40
20
21
770
820
19
20
690
740
1.60
1.40
21
22
900
950
20
21
780
800
1.60
1.40
22
23
990
1030
23
24
960
990
1.60
1.40
25
26
1190
1250
24
25
1010
1060
1.60
1.40
25
26
1250
1320
24
26
1070
1130
1.60
1.40
26
27
1330
1400
26
27
1270
1300
1.60
1.40
28
29
1530
1600
27
28
1330
1400
1.60
1.40
29
30
1610
1700
29
30
1460
1530
1.60
1.56
31
32
1800
1890
31
32
1660
1740
1.60
1.56
32
34
1970
2080
32
34
1880
1970
2.00
1.56
35
37
2440
2550

Ref Specication : IS 7098 Part-1


Cable Code : 2XY/2XFY/2XWY

Physical Parameters
Unarmoured (2XY)
No.
of
Cores

Nos
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Flat Strip Armoured (2XFY)

Minimum Nominal
Approx.
Approx.
Inner
Outer Overall Dia of Weight of Cable
Sheath
Cable
Sheath
Thickness Thickness Solid Std.
Soild
Std.
Cond. cond. Cond
cond.
mm
mm
mm mm Kg/Km Kg/Km
0.30
1.80
12
12
190
200
0.30
1.80
12
13
220
230
0.30
1.80
13
13
260
270
0.30
1.80
14
14
320
330
0.30
1.80
15
16
370
390
0.30
1.80
15
16
370
390
0.30
1.80
18
19
560
590
0.30
1.80
19
20
600
630
0.30
1.80
20
20
660
700
0.30
2.00
21
22
770
800
0.30
2.00
22
23
850
890
0.30
2.00
25
26
1140
1190
0.30
2.00
26
27
1200
1240
0.30
2.00
27
28
1290
1350
0.30
2.00
29
30
1520
1590
0.30
2.00
30
31
1640
1710
0.40
2.20
32
34
1930
2010
0.40
2.20
34
36
2140
2230
0.40
2.20
36
38
2430
2530

Dimension of
Armour
Strip
mm
N/A
N/A
N/A
N/A
N/A
N/A
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

Minimum
Outer
Sheath
Thickness
mm
N/A
N/A
N/A
N/A
N/A
N/A
1.24
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56

Approx.
Approx. Weight of
Approx.
Approx. Weight of Nominal Minimum
Cable
Overall Dia of
Cable
Outer Overall Dia of
Dia of
Cable
Cable
Armour Sheath
Wire
Thick- Soild Std.
Soild Std.
Soild
Std.
Soild
Std.
ness
Cond cond. Cond
cond.
Cond cond. Cond
cond.
mm mm Kg/Km Kg/Km mm
mm
mm mm Kg/Km Kg/Km
N/A N/A
N/A
N/A
1.40
1.24
13
14
390
410
N/A N/A
N/A
N/A
1.40
1.24
14
14
400
420
N/A N/A
N/A
N/A
1.40
1.24
15
15
450
470
N/A N/A
N/A
N/A
1.40
1.24
16
16
520
540
N/A N/A
N/A
N/A
1.40
1.24
17
17
590
620
N/A N/A
N/A
N/A
1.40
1.24
17
17
600
630
19
20
650
690
1.60
1.40
21
22
890
920
20
21
730
770
1.60
1.40
21
22
950
990
20
21
820
860
1.60
1.40
22
23
1030
1080
22
22
910
940
1.60
1.40
23
24
1140
1180
23
24
1000
1050
1.60
1.40
24
25
1240
1300
26
27
1240
1300
1.60
1.40
27
29
1510
1590
26
28
1340
1390
1.60
1.40
27
29
1600
1670
27
28
1430
1490
1.60
1.40
29
30
1730
1790
29
31
1670
1730
1.60
1.56
31
32
2020
2060
31
32
1820
1890
2.00
1.56
32
35
2150
2420
33
35
2030
2100
2.00
1.56
35
37
2590
2690
34
36
2280
2360
2.00
1.56
37
39
2840
2970
36
38
2580
2660
2.00
1.56
39
41
3190
3300

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

Cross-sectional view

1
2

3
4
5

Electrical Parameters
Number of
Cores
No's
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Max. Conductor
D.C.Resistance at
20 C
Ohm/Km
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10

3
4
5

Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : XLPE as per IS: 5831; Nominal Insulation Thickness : 0.70 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 7098 Part-1
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Approx. Conductor Reactance of Cable
A.C.Resistance
at 50 Hz (Approx.)
Ohm/Km
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49
15.49

Ohm/Km
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102
0.102

Normal Current Rating for XLPE Insulation

Capacitance of
Cable (Approx.)

Ground

Duct

Air

F/Km
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09
0.09

Amps
33
25
25
24
22
21
18
17
16
16
15
13
13
12
11
11
11
10
9

Amps
29
22
22
21
19
18
16
15
14
14
13
12
11
11
10
9
9
9
8

Amps
29
22
22
21
19
18
16
15
14
14
13
12
11
11
10
9
9
9
8

Short Circuit Current


Rating for 1 Second
Duration
K.amps
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215
0.215

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

34

Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : XLPE as per IS: 5831; Nominal Insulation Thickness : 0.70 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 7098 Part-1
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Round Wire Armoured (2XWY)

Number of
Cores
No's
2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
44
52
61

Max. Conductor
D.C.Resistance at
20 C
Ohm/Km
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41

Approx. Conductor Reactance of Cable


A.C.Resistance
at 50 Hz (Approx.)
Ohm/Km
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48
9.48

Ohm/Km
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100

Normal Current Rating for XLPE Insulation

Capacitance of
Cable (Approx.)

Ground

Duct

Air

F/Km
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10

Amps
39
34
34
31
29
27
24
22
21
20
19
17
16
16
15
14
14
13
12

Amps
32
30
30
28
26
25
21
20
19
18
17
16
16
14
13
13
13
12
11

Amps
32
30
30
28
26
25
21
20
19
18
17
16
16
14
13
13
13
12
11

Short Circuit Current


Rating for 1 Second
Duration
K.amps
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358
0.358

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

35

HT POWER CABLE

FEATURES

HT POWER CABLE
s (IGHCONTINUOUSCURRENTRATING
s (IGHERSHORTCIRCUITRATING
s (IGHEMERGENCYLOADCAPACITY
s ,OWDIELECTRICLOSS
s ,ONGERCHARGINGCURRNETS

s &REEFROMHEIGHTLIMITATIONMAINTENANCE
s 2ESISTANTTOVIBRATION MOISTURE CHEMICALCORROSSIVEGASES
s -UCHLONGERLIFEOFTHECABLE

APPLICABLE STANDARD
s )30ART 

HT POWER CABLE

36

37

LT/HT Power & Control Cables

Table - 25

LT/HT Power & Control Cables

Table - 26

TECHNICAL DETAILS FOR HAVELLS 3.3 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XWaY/2XWaY (3.3KV - EARTHED / UNEARTHED)

Physical Parameters

TECHNICAL DETAILS FOR HAVELLS 3.3 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

Approx. Weight of Cable


Size
(Cross Sectional Area)

Nominal Insulation
Thickness

Nominal Dia of Armor


Wire

Minimum Outer Sheath


Thickness

Approx. Overall Dia of


Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.60
2.80
3.00
3.30
3.50

mm
1.40
1.40
1.40
1.60
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.50

mm
1.24
1.24
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
2.04

mm
17
18
19
21
23
24
26
27
30
32
36
41
45
51
56

With Al'm Cond.


A2XWaY
Kg/Km
350
400
500
600
700
800
900
1050
1300
1500
1900
2300
2850
3550
4450

With Cu Cond.
2XWaY
Kg/Km
500
600
750
1000
1250
1500
1800
2150
2700
3300
4200
5250
6650
8450
10600

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (3.3KV - EARTHED / UNEARTHED)

Physical Parameters
Size
(Cross
Sectional
Area)
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Nominal
Minimum
Insulation Inner Sheath
Thickness Thickness
mm
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20

mm
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
0.70

Flat Strip Armoured (A2XFY/2XFY)


Approx. Weight of Cable
Nominal
Minimum
Approx.
With Al'm
With Cu
Armour
Outer
Overall Dia
Cond.
Cond.
Strip
Sheath
of Cable
Dimension Thickness
A2XFY
2XFY
mm
mm
mm
Kg/Km
Kg/Km
4 x 0.80
1.40
27
1000
1450
4 x 0.80
1.56
29
1200
1800
4 x 0.80
1.56
31
1400
2250
4 x 0.80
1.56
34
1650
2900
4 x 0.80
1.72
37
2000
3700
4 x 0.80
1.72
40
2350
4450
4 x 0.80
1.88
43
2700
5300
4 x 0.80
2.04
46
3150
6450
4 x 0.80
2.2
51
3850
8150
4 x 0.80
2.2
55
4350
9900
4 x 0.80
2.36
61
5400
12350

Nominal Dia
of Armor
Wire
mm
1.60
1.60
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15

Round Wire Armoured (A2XWY/2XWY)


Approx. Weight of Cable
Minimum
Approx.
With Al'm
With Cu
Outer
Overall Dia
Cond.
Cond.
Sheath
of Cable
Thickness
A2XWY
2XWY
mm
mm
Kg/Km
Kg/Km
1.56
30
1300
1750
1.56
33
1500
2100
1.56
35
1900
2750
1.56
38
2250
3450
1.72
42
2650
4300
1.88
45
3050
5150
2.04
48
3750
6400
2.04
51
4300
7600
2.20
56
5050
9400
2.36
60
5800
11250
2.68
67
7700
14600

- Tabulated approx. net weights of cables are only for guidelines for transportation / loading/ unloading purpose.

Cross-sectional view

- Tabulated approx. net weights of cables are only for guidelines for transportation / loading/ unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Cross-sectional view

Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type

Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural

Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip

Armouring : Single Layer of Aluminium Round Wire

Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type

Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type

Colour of Outer Sheath : Black or any other Colour as per requirement

Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters

Electrical Parameters

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium Copper Aluminium Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

K.amps
3.58
5.00
7.15
10.00
13.59
17.16
21.45
26.45
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.133
0.868
0.524
1.11
0.671
0.126
0.641
0.387
0.82
0.495
0.122
0.443
0.268
0.567
0.343
0.116
0.32
0.193
0.41
0.248
0.111
0.253
0.153
0.325
0.197
0.106
0.206
0.124
0.265
0.159
0.103
0.164
0.0991
0.211
0.127
0.100
0.125
0.0754
0.162
0.0976
0.097
0.10
0.0601
0.130
0.0778
0.095
0.0778
0.047
0.1023
0.0618
0.093
0.0605
0.0366
0.0808
0.0489
0.091
0.0469
0.0283
0.0648
0.0391
0.090
0.0367
0.0221
0.053
0.0319
0.088
0.0291
0.0176
0.0444
0.0268
0.086

F/Km
0.25
0.29
0.33
0.38
0.44
0.49
0.53
0.58
0.67
0.73
0.84
0.86
0.88
0.94
0.99

Amps
100
120
140
175
205
235
260
295
340
385
440
495
560
620
670

Amps
91
110
125
155
185
210
230
260
300
335
380
430
485
530
570

Amps
110
135
165
210
255
295
335
390
460
530
620
730
840
960
1070

Amps
130
155
185
225
265
300
335
380
435
490
550
610
680
740
780

Amps
115
140
165
200
235
265
300
335
385
430
480
530
590
630
660

Amps
145
175
215
270
330
380
430
495
590
670
780
900
1020
1140
1250

Short Circuit Current


Rating for 1 Second
Duration

Max. Conductor
Approx. Conductor
Size
Reactance
Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C
(Cross
of Cable Capacitance of
For Copper Conductor
Sectional
at 50 Hz Cable (Approx.) For Aluminium Conductor
Aluminium
Copper
Aluminium
Copper
Area)
(Approx.)
Ground Duct
Air
Ground Duct
Air

Aluminium

Copper

Sqmm
25
35
50
70
95
120
150
185
240
300
400

K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

K.amps
3.58
5.00
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.098
0.868
0.524
1.11
0.671
0.094
0.641
0.387
0.82
0.495
0.086
0.443
0.268
0.567
0.343
0.084
0.32
0.193
0.41
0.248
0.081
0.253
0.153
0.325
0.197
0.078
0.206
0.124
0.265
0.159
0.076
0.164
0.0991
0.211
0.127
0.075
0.125
0.0754
0.162
0.0976
0.073
0.1
0.0601
0.13
0.0778
0.072
0.0778
0.047
0.1023
0.0618
0.071

F/Km
0.25
0.29
0.33
0.38
0.44
0.49
0.53
0.58
0.67
0.73
0.84

Amps
94
115
135
165
195
220
245
280
320
360
410

Amps
80
95
110
140
165
185
210
235
270
305
350

Amps
99
120
145
185
225
255
295
340
400
460
535

Amps
120
145
170
210
250
285
315
355
410
460
520

Amps
100
120
145
175
210
240
270
300
350
390
440

Amps
125
155
190
235
290
330
375
435
510
590
670

Short Circuit Current


Rating for 1 Second
Duration

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

38

39

LT/HT Power & Control Cables

Table - 27

LT/HT Power & Control Cables

Table - 28

TECHNICAL DETAILS FOR HAVELLS 3.3 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (3.3KV - EARTHED / UNEARTHED)

Physical Parameters

Flat Strip Armoured (A2XFaY/2XFaY)


Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.60
2.80
3.00
3.30
3.50

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.60

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04

mm
19
20
21
23
24
26
27
29
32
34
37
42
47
52
56

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (3.3KV - EARTHED / UNEARTHED)

Physical Parameters

Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
480
550
600
700
850
950
1050
1200
1450
1700
2000
2500
3100
3750
4550

TECHNICAL DETAILS FOR HAVELLS 3.3 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
650
750
900
1100
1400
1650
1900
2300
2900
3500
4300
5450
6900
8650
10700

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.50
2.50

mm
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.20

Approx.
Overall Dia
of Cable
mm
20
22
23
24
26
27
29
31
34
36
40
45
49
55
60

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
550
700
600
800
700
950
800
1200
900
1450
1000
1700
1150
2050
1300
2400
1600
3050
1850
3650
2250
4550
2700
5650
3350
7150
4200
9050
5050
11200

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20

mm
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60
0.60
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.52
2.68

mm
33
35
39
42
46
49
53
56
61
67
74

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
1550
1750
2100
3500
2950
3350
3800
4400
5250
6150
7500

With Cu
Cond.
2XFY
Kg/Km
2000
2400
2950
3700
4650
5500
6450
7700
9600
11600
14450

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15

mm
1.56
1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.68
2.84

Approx.
Overall Dia
of Cable
mm
35
38
41
45
49
52
56
60
65
72
79

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
2150
2600
2450
3050
2750
3600
3250
4500
4100
5800
4600
6750
5250
7850
5950
9250
6850
11200
8650
14100
10200
17200

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound

Cross-sectional view

Insulation Material : XLPE (Cross linked polyethylene )


Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape

1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped
Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Filler : PVC Filler


Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.133
0.25
100
91
110
130
115
145
0.868
0.524
1.11
0.671
0.126
0.29
120
110
135
155
140
175
0.641
0.387
0.820
0.495
0.122
0.33
140
125
165
185
165
215
0.443
0.268
0.567
0.343
0.116
0.38
175
155
210
225
200
270
0.320
0.193
0.410
0.248
0.111
0.44
205
185
255
265
235
330
0.253
0.153
0.325
0.197
0.106
0.49
235
210
295
300
265
380
0.206
0.124
0.265
0.159
0.103
0.53
260
230
335
335
300
430
0.164
0.0991
0.211
0.127
0.100
0.58
295
260
390
380
335
495
0.125
0.0754
0.162
0.0976
0.097
0.67
340
300
460
435
385
590
0.100
0.0601
0.130
0.0778
0.095
0.73
385
335
530
490
430
670
0.0778
0.0470
0.1023
0.0618
0.093
0.84
440
380
620
550
480
780
0.0605
0.0366
0.0808
0.0489
0.091
0.86
495
430
730
610
530
900
0.0469
0.0283
0.0648
0.0391
0.090
0.88
560
485
840
680
590
1020
0.0367
0.0221
0.0530
0.0319
0.088
0.94
620
530
960
740
630
1140
0.0291
0.0176
0.0444
0.0268
0.086
0.99
670
570
1070
780
660
1250

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.098
0.868
0.524
1.11
0.671
0.094
0.641
0.387
0.820
0.495
0.086
0.443
0.268
0.567
0.343
0.084
0.320
0.193
0.410
0.248
0.081
0.253
0.153
0.325
0.197
0.078
0.206
0.124
0.265
0.159
0.076
0.164
0.0991
0.211
0.127
0.075
0.125
0.0754
0.162
0.0976
0.073
0.100
0.0601
0.130
0.0778
0.072
0.0778
0.0470
0.1023
0.0618
0.071

F/Km
0.25
0.29
0.33
0.38
0.44
0.49
0.53
0.58
0.67
0.73
0.84

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
94
80
99
115
95
120
135
110
145
165
140
185
195
165
225
220
185
255
245
210
295
280
235
340
320
270
400
360
305
460
410
350
535

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
100
125
145
120
155
170
145
190
210
175
235
250
210
290
285
240
330
315
270
375
355
300
435
410
350
510
460
390
590
520
440
670

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

40

41

LT/HT Power & Control Cables

Table - 29

LT/HT Power & Control Cables

Table - 30

TECHNICAL DETAILS FOR HAVELLS 3.8/6.6 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (6.6KV EARTHED)

Physical Parameters
Flat Strip Armoured (A2XFaY/2XFaY)
Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
2.80
2.80
2.80
2.80
2.80
2.80
2.80
2.80
2.80
3.00
3.30
3.50
3.50
3.50
3.60

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04

mm
19
20
22
23
25
26
28
30
32
35
38
44
48
52
56

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (6.6KV EARTHED)

Physical Parameters
Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
500
550
650
750
850
950
1100
1250
1500
1750
2100
2600
3150
3800
4550

TECHNICAL DETAILS FOR HAVELLS 3.8/6.6 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
650
750
900
1150
1400
1650
1950
2350
2900
3550
4400
5550
7000
8650
10700

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.50
2.50

Approx.
Overall Dia
of Cable

mm
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

mm
21
22
23
25
27
28
30
31
35
37
41
46
50
55
60

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
550
700
630
720
700
1000
800
1200
850
1500
1050
1750
1200
2050
1350
2450
1650
3100
1900
3700
2350
4650
2900
5800
3400
7200
4250
9100
5050
11200

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
2.80
2.80
2.80
2.80
2.80
2.80
2.80
2.80
2.80
3.00
3.30

mm
0.40
0.40
0.50
0.50
0.50
0.60
0.60
0.60
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.56
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84

mm
35
38
41
45
48
52
55
59
64
70
79

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
1700
1950
2300
2700
3150
3600
4100
4700
5550
6550
8150

With Cu
Cond.
2XFY
Kg/Km
2150
2600
3150
3900
4850
5750
6750
7950
9850
12000
15100

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15
3.15
4.00

mm
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
3.00

Approx.
Overall Dia
of Cable
mm
38
40
44
47
52
55
59
62
69
75
86

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
2400
2850
2650
3300
3050
3900
3450
4700
4400
6100
5050
7150
5550
8200
6300
9550
7950
12300
9250
14700
12250
19200

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening: Extruded Semiconducting Compound

Cross-sectional view

Insulation Material: Crosslinked Polyethylene (Xlpe)


1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Insulation Screening: Extruded Semiconducting Compound Followed By Helically Wrapped Copper Tape.

2. Conductor Screening : Extruded Semiconductor Compound

Pvc Fillers

3. Insulation Material : XLPE (Cross linked polyethylene )

Inner Sheath: Extruded Pvc

4. Insulation Screening : Extruded Semiconducting Compound followed by hellically


wrapped Copper Tape

Armouring: Single Layer Of Galvanized Flat Strip/ Round Wires.


Outer Sheath: Pvc Type St-2 Of Is: 5831 Options: Pvc Type St-2/ Fr Type/ Frls Type

5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Colour Of Outer Sheath: Black. Options: Any Other Colours As Per Requirement

6. Armouring : Single layer of Aluminium Round Wire / Flat Strip


7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.149
0.21
100
90
120
130
115
155
0.868
0.524
1.11
0.671
0.142
0.24
120
105
145
155
140
185
0.641
0.387
0.820
0.495
0.133
0.27
140
125
170
185
160
220
0.443
0.268
0.567
0.343
0.127
0.31
175
155
215
225
195
275
0.320
0.193
0.410
0.248
0.121
0.36
205
180
260
265
235
340
0.253
0.153
0.325
0.197
0.116
0.39
235
205
305
300
265
390
0.206
0.124
0.265
0.159
0.113
0.43
260
230
345
335
295
440
0.164
0.0991
0.211
0.127
0.109
0.47
295
260
395
380
330
510
0.125
0.0754
0.162
0.0976
0.105
0.53
340
300
470
435
380
600
0.100
0.0601
0.130
0.0778
0.104
0.54
385
335
540
490
425
680
0.0778
0.0470
0.1023
0.0618
0.102
0.57
440
380
630
550
480
790
0.0605
0.0366
0.0808
0.0489
0.100
0.60
495
430
730
610
530
910
0.0469
0.0283
0.0648
0.0391
0.096
0.67
560
480
840
680
580
1030
0.0367
0.0221
0.0530
0.0319
0.094
0.76
620
530
960
740
630
1140
0.0291
0.0176
0.0444
0.0268
0.092
0.82
680
580
1070
790
670
1250

Electrical Parameters
Short Circuit Current
Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.126
0.868
0.524
1.11
0.671
0.120
0.641
0.387
0.820
0.495
0.114
0.443
0.268
0.567
0.343
0.107
0.320
0.193
0.410
0.248
0.102
0.253
0.153
0.325
0.197
0.098
0.206
0.124
0.265
0.159
0.095
0.164
0.0991
0.211
0.127
0.093
0.125
0.0754
0.162
0.0976
0.090
0.100
0.0601
0.130
0.0778
0.090
0.0778
0.0470
0.1023
0.0618
0.087

F/Km
0.21
0.24
0.27
0.31
0.36
0.39
0.43
0.47
0.53
0.54
0.57

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
95
82
105
115
97
125
130
115
150
160
140
190
190
165
230
220
190
260
245
210
295
275
240
335
315
275
395
355
310
450
400
350
520

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
105
135
145
125
165
170
150
195
210
180
240
250
215
295
280
240
335
310
270
380
350
305
430
400
350
500
445
390
570
500
440
650

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

42

43

LT/HT Power & Control Cables

Table - 31

LT/HT Power & Control Cables

Table - 32

TECHNICAL DETAILS FOR HAVELLS 6.6/6.6KV & 6.35/11 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (6.6KV UNEARTHED / 11KV EARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFaY/2XFaY)


Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60

mm
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04

mm
21
22
23
25
27
28
30
32
34
36
39
44
48
52
56

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (6.6KV UNEARTHED / 11KV EARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
600
650
700
800
950
1050
1200
1350
1600
1800
2200
2650
3200
3800
4550

TECHNICAL DETAILS FOR HAVELLS 6.6/6.6KV & 6.35/11 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
700
850
1000
1200
1500
1750
2050
2450
3000
3600
4500
5600
7000
8700
10700

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
1.60
1.60
1.60
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50

Approx.
Overall Dia
of Cable

mm
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

mm
23
24
25
27
28
30
31
34
36
38
42
47
50
56
60

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
650
800
700
900
800
1050
900
1300
1000
1550
1150
1850
1300
2150
1500
2600
1750
3200
2000
3800
2400
4650
2900
5850
3400
7250
4250
9150
5050
11200

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60
3.60

mm
0.40
0.50
0.50
0.50
0.60
0.60
0.60
0.70
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
2.84

mm
39
42
45
48
52
56
59
63
68
73
80

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
2050
2300
2600
3000
3550
4000
4500
5100
6050
6950
8350

With Cu
Cond.
2XFY
Kg/Km
2500
2950
3450
4200
5250
6150
7150
8400
10350
12400
15300

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
4.00

mm
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.52
2.68
2.84
3.00

Approx.
Overall Dia
of Cable
mm
42
44
49
52
56
59
63
68
73
78
87

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
2750
3200
3100
3700
3800
4650
4250
5450
4950
6650
5450
7600
6100
8750
7500
10800
8600
12900
9750
15200
12550
19500

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor Screening : Extruded Semiconductor Compound

Cross-sectional view

Insulation Material : XLPE (Cross linked polyethylene)


1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape

2. Conductor Screening : Extruded Semiconductor Compound

Filler : PVC Filler

3. Insulation Material : XLPE (Cross linked polyethylene)

Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

4. Insulation Screening : Extruded Semiconducting Compound followed by hellically


wrapped Copper Tape

Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip


Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Colour of Outer Sheath : Black or any other color as per requirement

6. Armouring : Single layer of Aluminium Round Wire / Flat Strip


7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.164
0.18
100
90
120
130
115
155
0.868
0.524
1.11
0.671
0.156
0.20
120
105
145
155
140
185
0.641
0.387
0.820
0.495
0.147
0.22
140
125
170
185
160
220
0.443
0.268
0.567
0.343
0.139
0.26
175
155
215
225
195
275
0.320
0.193
0.410
0.248
0.133
0.29
205
180
260
265
235
340
0.253
0.153
0.325
0.197
0.127
0.32
235
205
305
300
265
390
0.206
0.124
0.265
0.159
0.124
0.35
260
230
345
335
295
440
0.164
0.0991
0.211
0.127
0.120
0.38
295
260
395
380
330
510
0.125
0.0754
0.162
0.0976
0.117
0.43
340
300
470
435
380
600
0.100
0.0601
0.130
0.0778
0.113
0.46
385
335
540
490
425
680
0.0778
0.0470
0.1023
0.0618
0.110
0.53
440
380
630
550
480
790
0.0605
0.0366
0.0808
0.0489
0.107
0.59
495
430
730
610
530
910
0.0469
0.0283
0.0648
0.0391
0.104
0.66
560
480
840
680
580
1030
0.0367
0.0221
0.0530
0.0319
0.100
0.74
620
530
960
740
630
1140
0.0291
0.0176
0.0444
0.0268
0.098
0.82
680
580
1070
790
670
1250

Electrical Parameters
Short Circuit Current
Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.133
0.868
0.524
1.11
0.671
0.126
0.641
0.387
0.820
0.495
0.118
0.443
0.268
0.567
0.343
0.116
0.320
0.193
0.410
0.248
0.107
0.253
0.153
0.325
0.197
0.102
0.206
0.124
0.265
0.159
0.099
0.164
0.0991
0.211
0.127
0.097
0.125
0.0754
0.162
0.0976
0.084
0.100
0.0601
0.130
0.0778
0.083
0.0778
0.0470
0.1023
0.0618
0.089

F/Km
0.18
0.20
0.22
0.26
0.29
0.32
0.35
0.38
0.43
0.46
0.53

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
95
82
105
115
97
125
130
115
150
160
140
190
190
165
230
220
190
260
245
210
295
275
240
335
315
275
395
355
310
450
400
350
520

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
105
135
145
125
165
170
150
195
210
180
240
250
215
295
280
240
335
310
270
380
350
305
430
400
350
500
445
390
570
500
440
650

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

44

45

LT/HT Power & Control Cables

Table - 33

LT/HT Power & Control Cables

Table - 34

TECHNICAL DETAILS FOR HAVELLS 11/11 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (11KV UNEARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFaY/2XFaY)


Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50

mm
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
2.20

mm
25
26
27
29
31
32
34
35
38
40
44
48
52
56
60

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (11KV UNEARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
750
800
900
1050
1150
1300
1450
1600
1850
2100
2500
3000
3500
4200
5000

TECHNICAL DETAILS FOR HAVELLS 11/11 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
900
1000
1150
1450
1700
2000
2300
2700
3250
3900
4750
5950
7300
9100
11100

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50

mm
1.40
1.56
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.20
2.36

Approx.
Overall Dia
of Cable
mm
26
28
29
31
33
35
36
38
40
43
46
52
55
60
64

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
800
950
900
1100
1000
1300
1100
1500
1350
1900
1450
2150
1600
2500
1750
2850
2050
3500
2300
4100
2750
5050
3400
6350
3950
7750
4700
9600
5500
11650

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50

mm
0.50
0.50
0.60
0.60
0.60
0.70
0.70
0.70
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.88
2.04
2.20
2.20
2.36
2.52
2.52
2.68
2.84
3.00
3.00

mm
48
51
54
57
61
65
68
72
77
82
89

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
2800
3100
3500
3950
4500
5050
5600
6300
7250
8300
9550

With Cu
Cond.
2XFY
Kg/Km
3250
3700
4350
5150
6200
7200
8250
9550
11600
13750
16500

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15
4.00
4.00

mm
2.04
2.20
2.20
2.36
2.52
2.52
2.68
2.84
3.00
3.00
3.00

Approx.
Overall Dia
of Cable
mm
52
54
58
61
66
70
73
77
82
89
95

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
4100
4550
4500
5100
4900
5750
5500
6700
6800
8500
7450
9600
8150
10750
8950
12250
10100
14400
12450
17900
14050
21000

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Insulation Material : XLPE (Cross linked polyethylene)

2. Conductor Screening: Extruded Semiconducting Compound

Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape

3. Insulation Material : XLPE (Cross linked polyethylene)

Filler : PVC Filler

4. Insulation Screening : Extruded Semiconducting Compound followed by hellically


wrapped Copper Tape

Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

6. Armouring : Single layer of Aluminium Round Wire / Flat Strip

Colour of Outer Sheath : Black or any other color as per requirement

Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip

7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.164
0.14
100
90
120
130
115
155
0.868
0.524
1.11
0.671
0.156
0.16
120
105
145
155
140
185
0.641
0.387
0.820
0.495
0.147
0.17
140
125
170
185
160
220
0.443
0.268
0.567
0.343
0.139
0.20
175
155
215
225
195
275
0.320
0.193
0.410
0.248
0.132
0.21
205
180
260
265
235
340
0.253
0.153
0.325
0.197
0.126
0.23
235
205
305
300
265
390
0.206
0.124
0.265
0.159
0.124
0.25
260
230
345
335
295
440
0.164
0.0991
0.211
0.127
0.120
0.26
295
260
395
380
330
510
0.125
0.0754
0.162
0.0976
0.116
0.29
340
300
470
435
380
600
0.100
0.0601
0.130
0.0778
0.112
0.32
385
335
540
490
425
680
0.0778
0.0470
0.1023
0.0618
0.109
0.35
440
380
630
550
480
790
0.0605
0.0366
0.0808
0.0489
0.105
0.39
495
430
730
610
530
910
0.0469
0.0283
0.0648
0.0391
0.102
0.43
560
480
840
680
580
1030
0.0367
0.0221
0.0530
0.0319
0.097
0.50
620
530
960
740
630
1140
0.0291
0.0176
0.0444
0.0268
0.096
0.56
680
580
1070
790
670
1250

Electrical Parameters
Short Circuit Current
Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.145
0.868
0.524
1.11
0.671
0.138
0.641
0.387
0.820
0.495
0.129
0.443
0.268
0.567
0.343
0.124
0.320
0.193
0.410
0.248
0.116
0.253
0.153
0.325
0.197
0.112
0.206
0.124
0.265
0.159
0.108
0.164
0.0991
0.211
0.127
0.105
0.125
0.0754
0.162
0.0976
0.102
0.100
0.0601
0.130
0.0778
0.0999
0.0778
0.0470
0.1023
0.0618
0.0954

F/Km
0.14
0.16
0.17
0.20
0.21
0.23
0.25
0.26
0.29
0.32
0.35

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
95
82
105
115
97
125
130
115
150
160
140
190
190
165
230
220
190
260
245
210
295
275
240
335
315
275
395
355
310
450
400
350
520

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
105
135
145
125
165
170
150
195
210
180
240
250
215
295
280
240
335
310
270
380
350
305
430
400
350
500
445
390
570
500
440
650

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

46

47

LT/HT Power & Control Cables

Table - 35

LT/HT Power & Control Cables

Table - 36

TECHNICAL DETAILS FOR HAVELLS 12.7/22 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (22KV EARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFaY/2XFaY)


Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

mm
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.04
2.20

mm
26
27
29
30
32
33
35
36
39
41
45
49
53
57
61

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (22KV EARTHED GRADE)

Physical Parameters
Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
780
850
950
1100
1250
1350
1500
1650
1900
2200
2600
3100
3650
4300
5100

TECHNICAL DETAILS FOR HAVELLS 12.7/22 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
820
1050
1250
1500
1800
2050
2350
2750
3300
4000
4900
6000
7450
9200
11200

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50

Approx.
Overall Dia
of Cable

mm
1.40
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36

mm
27
29
30
32
34
36
37
39
41
44
47
53
56
61
65

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
850
1000
950
1150
1050
1350
1200
1600
1400
1950
1550
2250
1650
2550
1900
2950
2150
3550
2400
4200
2800
5100
3500
6450
4050
7850
4800
9700
5650
11800

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00

mm
0.50
0.60
0.60
0.60
0.60
0.70
0.70
0.70
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
2.04
2.04
2.20
2.36
2.36
2.52
2.68
2.68
2.84
3.00
3.00

mm
51
53
56
60
63
67
71
74
79
84
91

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
3050
3300
3700
4250
4800
5350
5950
6550
7600
8500
9900

With Cu
Cond.
2XFY
Kg/Km
3500
3950
4550
5450
6500
7500
8600
9850
11900
13950
16850

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
4.00
4.00
4.00

mm
2.20
2.20
2.36
2.36
2.52
2.68
2.68
2.84
3.00
3.00
3.00

Approx.
Overall Dia
of Cable
mm
54
57
60
63
69
72
75
79
86
91
97

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
4350
4800
4750
5400
5250
6100
5800
7000
7150
8850
7800
9950
8550
11200
9350
12650
11700
16050
12800
18250
14500
21450

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound

Cross-sectional view

Insulation Material : XLPE (Cross linked polyethylene)

1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound

Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape

3. Insulation Material : XLPE (Cross linked polyethylene)

Filler : PVC Filler

4. Insulation Screening : Extruded Semiconducting Compound followed by hellically


wrapped Copper Tape

Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

6. Armouring : Single layer of Aluminium Round Wire / Flat Strip

Colour of Outer Sheath : Black or any other color as per requirement

Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip

7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.166
0.13
100
90
120
130
115
155
0.868
0.524
1.11
0.671
0.158
0.15
120
105
145
155
135
185
0.641
0.387
0.820
0.495
0.149
0.16
140
120
175
180
155
225
0.443
0.268
0.567
0.343
0.140
0.18
170
150
220
215
190
280
0.320
0.193
0.410
0.248
0.134
0.20
200
175
265
255
220
335
0.253
0.153
0.325
0.197
0.130
0.22
225
195
300
285
245
380
0.206
0.124
0.265
0.159
0.126
0.23
250
215
340
310
270
430
0.164
0.0991
0.211
0.127
0.122
0.25
280
240
385
345
300
485
0.125
0.0754
0.162
0.0976
0.118
0.27
315
275
450
390
335
560
0.100
0.0601
0.130
0.0778
0.113
0.30
345
300
500
420
360
620
0.0778
0.0470
0.1023
0.0618
0.110
0.32
385
330
570
455
395
690
0.0605
0.0366
0.0808
0.0489
0.107
0.36
415
360
640
480
415
750
0.0469
0.0283
0.0648
0.0391
0.103
0.40
450
385
720
510
440
820
0.0367
0.0221
0.0530
0.0319
0.0997
0.46
485
415
790
540
460
840
0.0291
0.0176
0.0444
0.0268
0.0970
0.52
510
435
850
550
475
940

Electrical Parameters
Short Circuit Current
Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.148
0.868
0.524
1.11
0.671
0.141
0.641
0.387
0.820
0.495
0.132
0.443
0.268
0.567
0.343
0.125
0.320
0.193
0.410
0.248
0.119
0.253
0.153
0.325
0.197
0.114
0.206
0.124
0.265
0.159
0.111
0.164
0.0991
0.211
0.127
0.107
0.125
0.0754
0.162
0.0976
0.104
0.100
0.0601
0.130
0.0778
0.102
0.0778
0.0470
0.1023
0.0618
0.097

F/Km
0.13
0.15
0.16
0.18
0.20
0.22
0.23
0.25
0.27
0.30
0.32

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
90
85
110
110
100
130
130
115
155
160
140
190
190
170
230
215
190
265
240
215
300
270
240
340
310
275
400
350
310
455
395
355
530

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
100
135
145
120
165
170
150
200
205
180
245
245
215
300
275
245
340
305
275
385
345
305
435
395
350
510
440
390
580
495
440
660

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

48

49

LT/HT Power & Control Cables

Table - 37

LT/HT Power & Control Cables

Table - 38

TECHNICAL DETAILS FOR HAVELLS 19/33 KV


SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (33KV EARTHED GRADE)

Physical Parameters

Flat Strip Armoured (A2XFaY/2XFaY)


Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

mm
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80

mm
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.36

mm
32
33
35
36
38
39
41
43
45
47
51
55
59
64
68

Ref Specication : IS 7098 Part-2


Cable Code : A2XFY/2XFY, A2XWY/2XWY (33KV EARTHED GRADE)

Physical Parameters
Flat Strip Armoured (A2XFY/2XFY)

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFaY
Kg/Km
1150
1200
1300
1450
1600
1750
1900
2100
2400
2650
3100
3600
4250
5000
5800

TECHNICAL DETAILS FOR HAVELLS 19/33 KV


THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES

With Cu
Cond.
2XFaY
Kg/Km
1250
1400
1600
1850
2150
2450
2750
3200
3850
4500
5400
6550
8050
9900
11900

Nominal dia
Minimum
of armor wire Outer Sheath
Thickness
mm
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15

mm
1.56
1.56
1.56
1.56
1.72
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.52

Approx.
Overall Dia
of Cable
mm
34
36
37
38
40
42
43
45
48
51
54
59
63
67
73

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWaY
2XWaY
Kg/Km
Kg/Km
1300
1450
1400
1600
1500
1750
1600
2000
1800
2350
1950
2650
2100
3000
2300
3400
2650
4050
3050
4850
3500
5750
4100
7050
4750
8600
5500
10400
6650
12800

Size
(Cross
Sectional
Area)

Nominal
insulation
thickness

Minimum
Inner
Sheath
Thickness

Nominal
Armour
Strip
Dimension

Minimum
Outer
Sheath
Thickness

Approx.
Overall
Dia of
Cable

Sqmm
25
35
50
70
95
120
150
185
240
300
400

mm
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80
8.80

mm
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70

mm
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80
4 x 0.80

mm
2.36
2.52
2.52
2.68
2.84
2.84
3.00
3.00
3.00
3.00
3.00

mm
64
67
69
73
77
80
84
87
92
96
103

Round Wire Armoured (A2XWaY/2XWaY)

Approx. Weight of
Cable
With Alm
Cond.
A2XFY
Kg/Km
4050
4850
5250
5850
6500
7050
7750
8350
9250
10300
11800

With Cu
Cond.
2XFY
Kg/Km
4900
5450
6100
7050
8200
9200
10350
11650
13600
15750
18750

Minimum
Nominal dia
Outer Sheath
of armor wire
Thickness
mm
3.15
3.15
3.15
3.15
3.15
4.00
4.00
4.00
4.00
4.00
4.00

mm
2.52
2.68
2.68
2.84
3.00
3.00
3.00
3.00
3.00
3.00
3.00

Approx.
Overall Dia
of Cable
mm
69
72
75
78
82
87
90
93
98
103
109

Approx. Weight of
Cable
With Alm
With Cu
Cond.
Cond.
A2XWY
2XWY
Kg/Km
Kg/Km
6850
7300
7300
7900
7900
8750
8500
9750
9350
11050
11150
13250
12000
14650
12750
16050
13950
18250
15200
20650
16900
23850

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130

Insulation Material : XLPE (Cross linked polyethylene)

2. Conductor Screening : Extruded Semiconductor Compound

Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape

3. Insulation Material : XLPE (Cross linked polyethylene)

Filler : PVC Filler

4. Insulation Screening : Extruded Semiconducting Compound followed by hellically wrapped Copper Tape

Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip

6. Armouring : Single layer of Aluminium Round Wire / Flat Strip

Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type

Colour Of Outer Sheath: Black. Options: Any Other Colours As Per Requirement

Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters

Electrical Parameters
Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Approx. Conductor
A.C.Resistance at
90 C

Normal Current Rating


Reactance Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
For Aluminium Conductor
For Copper Conductor
Aluminium Copper
(Approx.)
Ground
Duct
Air
Ground
Duct
Air
Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km
F/Km
Amps Amps Amps Amps Amps Amps
1.20
0.727
1.54
0.931
0.175
0.10
100
90
120
130
115
155
0.868
0.524
1.11
0.671
0.169
0.11
120
105
145
155
135
185
0.641
0.387
0.820
0.495
0.161
0.12
140
120
175
180
155
225
0.443
0.268
0.567
0.343
0.152
0.14
170
150
220
215
190
280
0.320
0.193
0.410
0.248
0.145
0.15
200
175
265
255
220
335
0.253
0.153
0.325
0.197
0.140
0.16
225
195
300
285
245
380
0.206
0.124
0.265
0.159
0.135
0.18
250
215
340
310
270
430
0.164
0.0991
0.211
0.127
0.130
0.19
280
240
385
345
300
485
0.125
0.0754
0.162
0.0976
0.126
0.21
315
275
450
390
335
560
0.100
0.0601
0.130
0.0778
0.122
0.23
345
300
500
420
360
620
0.0778
0.0470
0.1023
0.0618
0.117
0.25
385
330
570
455
395
690
0.0605
0.0366
0.0808
0.0489
0.113
0.27
415
360
640
480
415
750
0.0469
0.0283
0.0648
0.0391
0.111
0.29
450
385
720
510
440
820
0.0367
0.0221
0.0530
0.0319
0.105
0.34
485
415
790
540
460
840
0.0291
0.0176
0.0444
0.0268
0.102
0.37
510
435
850
550
475
940

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60
47.00
59.22
75.20
94.00

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.10
114.40
143.00

Max. Conductor
Size
D.C.Resistance at
(Cross
20 C
Sectional
Area)
Aluminium Copper
Sqmm
25
35
50
70
95
120
150
185
240
300
400

Approx. Conductor
A.C.Resistance at
90 C
Aluminium

Copper

Reactance
Capacitance
of Cable at
of Cable
50 Hz
(Approx.)
(Approx.)

Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km


1.20
0.727
1.54
0.931
0.160
0.868
0.524
1.11
0.671
0.153
0.641
0.387
0.820
0.495
0.146
0.443
0.268
0.567
0.343
0.138
0.320
0.193
0.410
0.248
0.130
0.253
0.153
0.325
0.197
0.125
0.206
0.124
0.265
0.159
0.122
0.164
0.0991
0.211
0.127
0.118
0.125
0.0754
0.162
0.0976
0.113
0.100
0.0601
0.130
0.0778
0.111
0.0778
0.0470
0.1023
0.0618
0.106

F/Km
0.10
0.11
0.12
0.14
0.15
0.16
0.18
0.19
0.21
0.23
0.25

Normal Current Rating


For Aluminium Conductor
Ground
Duct
Air
Amps Amps Amps
90
85
110
110
100
130
130
115
155
160
140
190
190
170
230
215
190
265
240
215
300
270
240
340
310
275
400
350
310
455
395
355
530

For Copper Conductor


Ground
Duct
Air
Amps Amps Amps
120
100
135
145
120
165
170
150
200
205
180
245
245
215
300
275
245
340
305
275
385
345
305
435
395
350
510
440
390
580
495
440
660

Short Circuit Current


Rating for 1 Second
Duration
Aluminium
K.amps
2.35
3.29
4.70
6.58
8.93
11.28
14.10
17.39
22.56
28.20
37.60

Copper
K.amps
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

50

51

BASIC ASSUMPTION FOR CURRENT RATINGS & RATING FACTORS

BASIC ASSUMPTION FOR CURRENT RATINGS & RATING FACTORS

SCOPE
The current ratings of cables as indicated in various tables have been calculated on certain assumed conditions.
In actual practice these conditions may be different. Therefore to determine the actual current ratings as per installation conditions, the tabulated
ratings shall be multiplied with appropriate factors

Group Rating Factors


1. Cable laid direct in Ground

a) Basic assumption for current ratings


I) Maximum permissible temperature - 90C for XLPE insulation, 70C for general purpose PVC, 85C for HR PVC
ii) Ground/Duct temperature - 30C
iii) Ambient temperature - 40C
iv) Thermal resistivity of soil - 150C cm/W
v) Thermal resistivity of Dielectric 650C cm/W for PVC, 350C cm/W for XLPE
vi) Single core cables installed in one circuit in following arrangement
Voltage Grade
OR
1.1KV cables
vi) Multicore cables installed in single circuit

b) Rating Factors
i) Rating factors related to variation in ambient air temperature
Air Temperature in Deg.
Normal PVC
Rating factors

Depth of Laying
750mm

3.3KV to 11KV

900mm

More than 11KV

1050mm

20

25

30

35

40

45

50

55

1.32

1.25

1.16

1.09

1.00

0.90

0.80

0.80

HR PVC

1.22

1.17

1.12

1.06

1.00

0.94

0.87

0.80

XLPE

1.20

1.16

1.11

1.06

1.00

0.95

0..88

0.82

No of cables/
circuits in groups
2
3
4
5
6
7
8
9
10
11
12

Multicore cables in horizontal formation


Touching

S=15CM

S=30CM

S=45CM

S=60CM

Touching

S=15CM

S=30CM

S=45CM

S=60CM

0.80
0.68
0.62
0.58
0.55
0.52
0.50
0.48
0.46
0.45
0.44

0.84
0.74
0.69
0.65
0.62
0.59
0.57
0.55
0.54
0.53
0.52

0.87
0.79
0.75
0.72
0.69
0.67
0.66
0.65
0.64
0.63
0.62

0.90
0.83
0.80
0.77
0.75
0.73
0.72
0.71
0.70
0.70
0.69

0.91
0.86
0.83
0.80
0.78
0.77
0.75
0.75
0.74
0.74
0.73

0.80
0.70
0.64
0.59
0.55
0.53
0.51
0.49
0.48
0.47
0.46

0.85
0.78
0.73
0.70
0.67
0.65
0.64
0.63
0.63
0.62
0.61

0.90
0.85
0.81
0.79
0.77
0.76
0.76
0.74
0.74
0.73
0.73

0.92
0.88
0.86
0.84
0.83
0.82
0.82
0.81
0.81
0.80
0.80

0.95
0.91
0.89
0.88
0.87
0.86
0.86
0.85
0.85
0.84
0.84

S = axial spacing of cable


No. of cables/
circuits in groups

No. of Tier

2
3
4
5
6
7
8
9
10
11
12

1
1
2
2
2
3
3
3
4
4
4

Multicore cables in Tier formation

ii) Rating factors related to variation in ground temperature


Air Temperature in Deg.
Normal PVC
Rating factors

15

20

25

30

35

40

45

50

1.17

1.12

1.06

1.00

0.94

0.87

0.79

0.71

HR PVC

1.13

1.09

1.04

1.00

0.95

0.90

0.85

0.80

XLPE

1.12

1.08

1.04

1.00

0.96

0.91

0..87

0.82

iii) Rating factors related to variation in ground thermal resistivity of soil for 3 single core cables laid direct in ground. (Average value)
Thermal Res. in oC.Cm/W

100

120

150

200

250

300

Rating factors

1.20

1.10

1.00

0.90

0.81

0.74

iv) Rating factors related to variation in ground thermal resistivity of soil for multi core cables laid direct in ground. (Average value)
Thermal Res. in oC.Cm/W

100

120

150

200

250

300

Rating factors

1.16

1.08

1.00

0.90

0.82

0.76

v) Rating factors related to variation in depth of laying for 1.1kv cables


1. For cross-sectional area of conductor < 25sqmm

Single cables in horizontal formation

Touching
0.80
0.68
0.60
0.55
0.51
0.48
0.46
0.44
0.42
0.41
0.40

S=15CM
0.84
0.74
0.66
0.61
0.57
0.54
0.51
0.48
0.47
0.46
0.45

S=30CM
0.87
0.79
0.73
0.68
0.63
0.59
0.56
0.53
0.52
0.50
0.49

S=45CM
0.90
0.83
0.77
0.71
0.67
0.63
0.60
0.57
0.55
0.54
0.53

S=60CM
0.91
0.86
0.79
0.73
0.69
0.64
0.61
0.58
0.56
0.55
0.54

2. Cable laid direct in open racks in air


(i) Multicore Cables in open racks in air

No. of racks

Depth of laying (cm) >

75

90

105

120

150

180 & Above

Rating factors

1.00

0.99

0.98

0.97

0.96

0.95
No. of racks

2. For cross-sectional area of conductor 25 to 300sqmm

No. of cables per rack

No. of cables per rack

Depth of laying (cm) >

75

90

105

120

150

180 & Above

1.00

0.98

0.96

0.93

0.92

1.00

0.84

0.80

0.75

0.73

Rating factors

1.00

0.98

0.97

0.96

0.94

0.93

1.00

0.95

0.93

0.90

0.89

1.00

0.80

0.76

0.71

0.69

1.00

0.94

0.92

0.89

0.88

1.00

0.78

0.74

0.70

0.68

1.00

0.93

0.90

0.87

0.86

1.00

0.76

0.72

0.65

0.66

3. For cross-sectional area of conductor above 300sqmm


Depth of laying (cm) >

75

90

105

120

150

180 & Above

Rating factors

1.00

0.97

0.96

0.95

0.92

0.91

(ii) Single Core Cables In open racks In air

vi) Rating factors related to variation in depth of laying for 3.3kv to 11kv cables
Depth of laying (cm) >

75

90

105

120

150

180 & Above

Rating factors

1.00

0.99

0.98

0.96

0.95

vii) Rating factors related to variation in depth of laying for above 11kv cables

No. of Racks

Depth of laying (cm) >

75

90

105

120

150

180 & Above

Rating factors

1.00

0.99

0.98

0.96

52

1
2
3
4

No. of Circuit Racks (3 single cores) per rack


1
2
6
1
0.98
0.96
1
0.95
0.93
1
0.94
0.92
1
0.93
0.9

53

S = axial spacing of cable


No. of cables/
circuits in groups
2
3
4
5
6
7
8
9
10
11
12

1
1
2
2
2
3
3
3
4
4
4

No. of cables/
circuits in groups

Multicore cables in Tier formation


Touching
0.80
0.68
0.60
0.55
0.51
0.48
0.46
0.44
0.42
0.41
0.40

S=15CM
0.84
0.74
0.66
0.61
0.57
0.54
0.51
0.48
0.47
0.46
0.45

Multicore cable (Touching)


No of cables in racks
1
1.00
0.84
0.80
0.76

1
2
3
4

Standard drum lengths of cables

No. of Tier

2
1.00
0.80
0.76
0.71

3
1.00
0.78
0.74
0.70

4
1.00
0.76
0.72
0.68

* Selection criteria of MV/HV


cable size for primary distribution

Estimated Voltage Drops


in PVC/XLPE Aluminium Cables For
A.C. System

SCOPE
The conductor size in the cables for any installation is also governed by its ability to carry short circuit current of system.
For L.V. distribution cable may be selected on the basis of continuous load current. But in case of MV/HV distribution it is
always safer to select the cable on the basis of ability of conductor to carry expected short circuit current. Short circuit
current rating of cable should in line with short circuit capacity of damping apparatus such as circuit breakers, Transformers
& reactor etc. beside its capacity to carry desired load current. Short circuit ratings of cables each size are given in relevant
tables & have been calculated on the basis of IEC-949 & IEC-986 & on the following assumption

(Voltage drop - Volts/Km/Amps)


Nominal
area of
conductor
(sq. mm)

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

P.V.C. Cable
Single
Phase
43.44
29.04
17.78
11.06
7.40
4.58
2.89
2.10
1.55
1.10
0.79
0.63
0.52
0.42
0.34
0.28
0.24
0.23
0.20
0.19
0.18

Three
Phase
37.62
25.15
15.40
9.58
6.41
3.97
2.50
1.80
1.30
0.94
0.68
0.55
0.46
0.37
0.30
0.26
0.22
0.20
0.18
-

XLPE Cable
Single
Phase
46.34
30.98
18.98
11.80
7.88
4.90
3.08
2.23
1.65
1.15
0.83
0.66
0.55
0.44
0.35
0.30
0.24
0.23
0.21
0.20
0.18

STANDARD LENGTH (MTS) WITH 5% TOLERANCE

S=30CM S=45CM S=60CM


0.87
0.90
0.91
0.79
0.83
0.86
0.73
0.77
0.79
0.68
0.71
0.73
0.63
0.67
0.69
0.59
0.63
0.64
0.56
0.6
0.61
0.53
0.57
0.58
0.52
0.55
0.56
0.50
0.54
0.55
0.49
0.53
0.54
Multicore cables (spacing of cable S/core cables in trefoil touching formation
equal to dia meter of cable No of spacing between circuits equal to twice the
cables in racks
diameter of cable) No of cables in racks
1
2
3
4
1
2
3
4
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.98
0.95
0.94
0.93
0.98
0.95
0.94
0.93
0.96
0.93
0.92
0.90
0.96
0.93
0.92
0.90
0.93
0.90
0.89
0.87

Three
System
40.13
26.83
16.44
10.22
6.82
4.24
2.67
1.94
1.44
1.00
0.70
0.56
0.48
0.40
0.30
0.26
0.22
0.20
0.18
-

b) Maximum permissible conductor temperature during short circuit


i) With XLPE insulation - 250 Deg. C
ii) With PVC insulation - 160 Deg. C
c) Volumetric specic heat of the conductor
i) With Aluminium conductor - 2.5 x 10-3J/Deg. C/MM3
ii) With Copper conductor - 3.45 x 10-3J/Deg. C/MM3
d) Reciprocal of temperature co-efcient of resistance at 9 Deg. C
i) With Aluminium conductor - 228
ii) With Copper conductor - 234.5
Short circuit current rating at different duration may be calculated as
Ish (for t duration) = Ish (for 1Sec.)
Ish for 1 Sec. Duration is given in relevant tables in KA
t
t = Time duration required tobe calculated of short circuit in Sec.
SELECTION CRITERIA OF H.V./MV CABLES FOR PRIMARY DISTRIBUTION
REQUIRED DATAS
FOR EXAMPLE
1) Nominal System voltage at H.T. Side
11KV
2) Short circuit level for H.T. system
25KA
3) Fault withstand time for H.T. CBs
0.5 SEC
4) Formula for calculating H.T. cable size
With Aluiminium cond./XLPE insulated cable = Ish X t
= 25 X0.5
0.094
0.094
= 188

With Copper cond./XLPE insulated cable =

Hence nearest higher size 240sqmm is required


Ish X t
=
25 X 0.5
0.143
0.143
=
124
Hence nearest higher size 150 sqmm is required

ELECTRICAL FORMULAS FOR CALCULATING A.C. LOAD CURRENT

Load current in Amps when Kilo Watt is given

Load current in Amps when H.P. is given

STRIP ARMOURED

ROUND WIRE ARMOURED

~ SINGLE CORE

UP TO 150SQMM-1000
185 TO 1000sqmm-500

UP TO 150SQMM-1000
185 to 1000sqmm-500

UP TO 150SQMM-1000
185 to 1000sqmm-500

~ TWO CORE

UP TO 50SQMM-1000
70 to 630sqmm-500

UP TO 50SQMM-1000
70 to 630sqmm-500

UP TO 50SQMM-1000, 70 TO
500sqmm
500, 630sqmm-250

~ THREE CORE

UP TO 50SQMM-1000
70 to 630sqmm-500

UP TO 50SQMM-1000
70 to 500sqmm-500
630sqmm-250

UP TO 50SQMM-1000, 70 TO
300sqmm
500, 500 to 630sqmm-250

~ THREE & HALF CORE

UP TO 50SQMM-1000
70 to 630sqmm-500

UP TO 50SQMM-1000
70 to 400sqmm-500
500 to 630sqmm-250

UP TO 50SQMM-1000, 70 TO
300sqmm
500, 400-630sqmm-250

FOUR CORE

UP TO 50SQMM-1000
70 to 500sqmm-500
630sqmm-250

UP TO 50SQMM-1000
70 to 400sqmm-500
500 to 630sqmm-250

UP TO 50SQMM-1000, 70 to
240sqmm
500, 300 to 630sqmm-250

~ SINGLE CORE

UP TO 150SQMM-1000
185 TO 630sqmm-500
800 to 1000sqmm-250

UP TO 150SQMM-1000
185 to 630sqmm-500
800 to 1000sqmm-250

UP TO 150SQMM-1000
185 to 630sqmm-500
800 to 1000sqmm-250

~ TWO CORE

UP TO 10SQMM-1000
16 to 300sqmm-500
400 to 630sqmm-250

UP TO 10SQMM-1000
16 to 300sqmm-500
400 to 630sqmm-250

UP TO 10SQMM-1000, 70 TO
500sqmm 500,
500, 300 to 630sqmm-250

~ THREE CORE

UP TO 10SQMM-1000
300 to 400sqmm-250

UP TO 10SQMM-1000
16 to 240sqmm-500
240sqmm-400sqmm-250

UP TO 10SQMM-1000, 16 TO
185sqmm
16 to 185sqmm-500
500, 240 to 400sqmm-250

~ THREE & HALF CORE

UP TO 10SQMM-1000
300 to 400sqmm-250

UP TO 10SQMM-1000
16 to 240sqmm-500
240 to 400sqmm-250

UP TO 10SQMM-1000, 16 TO
150sqmm
16 to 185sqmm-500
500, 185 to 400sqmm-250

FOUR CORE

UP TO 10SQMM-1000
16 to 240sqmm-500
300 to 400sqmm-250

UP TO 10SQMM-1000
16 to 150sqmm-500
240 to 400sqmm-250

UP TO 10SQMM-1000, 16 to
150sqmm
500, 185 to 400sqmm-250

1/11KV GRADE

19/33KV GRADE

1.1KV PVC/XLPE CABLES


WITH ALUMINIUM

1.1KV PVC/XLPE CABLES


WITH COPPER CONDUCTOR

a) Temperature of conductor just prior to short circuit


i) With XLPE insulation - 90 Deg. C
ii) With PVC insulation - 70 Deg. C

**Above voltage drops (volts/km/amps) shall be multiplied


with rated current & length of Cable in K.M. to calculate
total voltage drop in particular length and size of cables.

Load current in Amps when KVA is given

DESCRIPTION OF CABLE UN-ARMOURED

for Single phase (A.C.)


KVA X1000
V
for Single phase (A.C.)
KW X1000
VXpf
for Single phase (A.C.)
H.P. X746
V X %EFf X pf

for Three phase (A.C.)


KVA X1000
1.732 X V
for Three phase (A.C.)
KW X1000
1.732 X V X pf
for Three phase (A.C.)
H.P. X746
1.732 X V X %Eff X pf

- Control cables more than FOUR CORES shall be supplied in 500 mts length
DESCRPITON OF CABLE

6.35/11KV GRADE

H.T. XLPE CABLES WITH ALUMINIUM CONDUCTOR


~ SINGLE CORE-A2XWaY

UP TO 150SQMM-1000
185 to 1000sqmm-500

UP TO 150SQMM-1000
185 to 1000sqmm-500

UP TO 150SQMM-1000
185 to 1000sqmm-500

~ THREE CORE-A2XFY

25 TO 300SQMM-500
400sqmm-250

25 TO 185SQMM-500
240 to 400sqmm-250

25 TO 95SQMM-500
120 to 400sqmm-250

~ THREE CORE-A2XWY

25 TO 150SQMM-500
185 to 300sqmm-250
400sqmm-200

25 TO 95SQMM-500
120 to 240sqmm-250
300 to 400sqmm-200

25 TO 50SQMM-250
70 to 120sqmm-250
185 to 400sqmm-200

V = Nominal system voltage in Volts, pf = Power factor, KVA = Kilo Volts Ampere, H.P. = Horse Power

54

55

Selection Guide

Quality Control
It has been rightly said that Quality is never an accident, it is
always the result of intelligent efforts.
In the manufacture of cables, intelligent efforts are incorporated
to achieve quality. For a quality end products, control starts from
proper design of the product. All raw materials are selected
carefully and only materials of high quality are used in production.
Having done this, stage wise inspection is done to ensure
conformity with the requirements of relevant Indian Standards
where these apply.

Test
The tests on cables have been classied broadly in four categories
as follows:
Routine Tests:

List of Tests as per IS:1554(Part - I): 1988, IS:1554


(Part- II):1988, IS:7098 (Part - I):1988 and IS:7098
(Part-II) : 1985
1.

Routine Tests:
a) Conductor Resistance Test
b) High Voltage Test
c) Armour Resistance Test for mining Type Cables
d) Partial Discharge test (for H.T. Screened cable)

2.

Type Tests:
a) Tensile Test (for Aluminium Conductor)
b) Wrapping Test (for Aluminium Conductor)
c) Annealing Test (for Copper Conductor)
d) Conductor Resistance Test
e) Test for Armour Wires/Strips
f)
Test for thickness of Insulation & Sheath
g) Physical Test for Insulation & Outer Sheath
h) Insulation Resistance Test
i)
High Voltage Test
j)
Flammability Test
k) Hot Set Test - (For XLPE Insulation only)
l)
Partial Discharge test (for H.T. Screened cable)
m) Bending test (for H.T. Screened cable)
n) Dielectric Power factor test (for H.T. Screened cable
with rated voltage 6.35/11KV & above)
o) Heating cycle test (for H.T. Screened cable)
p) Impulse withstand test (for H.T. Screened cable)

Tests carried out on each cable to check the requirements which


are likely to vary during production.
Type Tests:

Stage - Wise Inspection


i) Wire-Drawing

ii) Stranding of Wires:

iii) Insulation :

: Wire diameter
Surface
Shape
Quality of joints in the wire
: Quality of joints in the wires
Compaction of conductor
Shape of Conductor
Dimensions
Resistance of Conductor
: Dimension over Insulation,
Thickness of Insulation,

iv) Curing
(for XLPE Insulation)

: Hot set test, Tensile strength &


elongation test.

v) Screening
: Dimension over screen, thick of
(for H.T. Screened cables) screen visual examination of
surface/defects.
v) Laying Up

: Sequence of Cores
Direction of lay
Diameter over laid up cores
Circularity

vi) Inner Sheath

vii) Armouring

: Thickness of Sheath
Diameter over Sheath
Surface Uniformity
Circularity
Porosity
: Diameter of Wires/
Dimensions of Strips
Direction of lay
Coverage
Quality of Joints of Wires

Tests carried out to prove conformity with the specication.


These are intended to prove the general qualities and design of a
given type of cable.
Acceptance Tests:
Tests carried out on samples taken from a lot for the purpose of
acceptance of the lot.
Optional Tests:
Special tests to be carried out when required by agreement
between the purchaser and the manufacturer.
Special tests required for FRLS Cables can also be carried out at
our works i.e. Halogen gas generation test to IEC - 754 Part - I,
Smoke generation test to ASTMD 2843, Oxygen index test and
Temperature index test to ASTMD - 2863, Flammability test to (1)
IEC-332-1, (2) Swedish Chimney test to SS-4241475 Class F3 &
(3) IEC-332-3, Flame resistance test to IEEE-383.
Together with the most advanced equipment available, we are
able to offer to our valued customers assurances of highest
quality and strict adherence to the required specication. As a
third party guarantee, our cables have passed rigorous tests at
various Government recogonized test laboratories such as CPRI,
Shri Ram Test House, ERDA Baroda, National Test House, ERTL,
RTC.
Routine Tests, Type Tests, Acceptance Tests and Optional Tests
as per the Indian Standard Specication for Power and Control
Cables with PVC insulation, Cross linked Polyethylene insulation
and Special Tests are given in the Annexure.

Tensile Testing Machine

viii) Outer Sheath

: Thickness of Sheath Diameter


over Sheath Tightness of Sheath
Eccentricity Porosity, Embossing

Acceptance Tests:
a) Tensile Test (For Aluminium Conductor)
b) Wrapping Test (For Aluminium Conductor)
c) Annealing Test (For Copper Conductor)
d) Conductor Resistance Test
e) Test for thickness of Insulation & Sheath
f)
High Voltage Test
g) Insulation Resistance Test
h) Tensile Strength & Elongation at break test for
Insulation and Sheath
I)
Hot Set Test - (for XLPE Insulation only)
j)
Partial Discharge test (for H.T. Screened cable)

4.

Optional Tests:
a) Cold Bend Test
b) Cold Impact Test
c) Armour Resistance Test
(for other than Mining Type Cables)

5.

Special Tests (As Applicable):


a) Oxygen Index Test as per ASTMD - 2863-77
b) Temp. Index Test as per ASTMD - 2863-77
c) Smoke Generation Test as per ASTMD - 2843-77
d) Acid Gas Generation Test as per IEC - 754-1
e) Flammability Test as per IEC - 332-1, IEEE-383,
SS-4241475 Class F3 and IEC - 332-3
g) Water absorption test (by Electrical Method)
h) Ultra voilet resistance to ASTM-G-53
i)
Die electric Strength retention test
j)
Test for Antirodent & Antitermite property

For selection of a cable, a rst hand knowledge of the system


in which the cable is to be used, and the installation conditions
under which the cable has to operate, is necessary. A knowledge
of statutory restrictions and the manufacturing facilities available
in the country will help in nding out as to what type of cable will
be available for particular usage. The environmental conditions
under which the cable has to operate will decide its protective
covering. Thus once voltage grade of the cable, number of cores,
conductor material, type of insulation and protective coverings
are known, size of conductor remains to be decided. The rst
and foremost criteria for the size of conductor is continuous
current rating for the present load. There after the same should
be checked for short circuit, voltage drop, over load capacities
and future expansions. Once decided the selection of next higher
size compared to what is essential for the requirement, will always
be worthwhile.
Economic considerations are also necessary.
INFORMATION REQUIRED WITH ENQUIRY & ORDER
The following information should be included in an enquiry:
i)

Voltage Grade.

ii)

Whether cable is to be used on Earthed or Unearthed


system (for voltages above 3.3 KV).

iii)

Type of installation whether in air or in ducts or in ground.

iv)

If cables are grouped together, then number of cables in


group and vertical and horizontal spacing between them.

v)

Required value and duration of short circuit current.

Following further informations are also required for offering the


exact type of cable for any specic purpose:
a)

The normal ambient or operating temperature.

b)

The maximum temperature to which the PVC will be ex


posed and the duration and frequency of such exposures.

c)

The material with which the PVC will be in contact i.e.


oil, gases, acids, alkalies etc. at normal and maximum
temperature.

d)

If special ame retardent property is required.

e)

If any special electrical characteristics needed.

RM Testing Lab

56

57

LIST OF MAJOR CUSTOMER

Handling & Storage


Handling (Unloading at site) : On receipt of cable drums visual inspection
of drums should be made ensuring drum packing is original. While
unloading the cables certain precautions are to be taken to ensure the
safety of the cables.
1. The cable drums should not be dropped or thrown from rail way
wagons or trucks during unloading operations as the shock may
cause serious damage to cable layers. A crane should be used
for unloading cable drums. When lifting drums with the crane, it is
recommended that the lagging should be kept in place to prevent
the anges from curshing on to the cable. If the crane is not available,
a ramp should be prepared with approximate inclination of 1:3 or
1:4. The cable drum should be rolled over the ramp by means of
ropes and winches. Additionally a sand bed at the foot of the ramp
may be prepared to brake the rolling the cable drum.
2. Cable should not be dragged along the earth surface.
3. Cable ends should always be sealed by means of suitable end
sealing materials to prevant moisturisation of cores and armour.
4. Drums should be rolled in direction of arrow marked on the drum.
Roll this way

Storage:
Cables should be stored in a dry covered place to prevent exposure
to climatic conditions and wear and tear of wooden drums and it
should preferably on a concrete surface/rm surface which will not
cause the drums to sink and thus lead to ange rot and extreme
difculty in moving the drums.
All drums should be stored in such a manner as to leave sufcient
space between them for air circulation. It is desirable for drums to
stand on battens placed directly under the anges.
In no case should the drums be stored, On the Flat, i.e., with ange
horizontal.

n case of multicore power cables, cables shall be laid side by side, with
spacings not less than one cable diameter. However derating factors for
cables laid on trenches are to be referred.
Multicore power cables and single core D.C. circuits may be clamped
by means of galvanised mild steel saddles but 1.1 KV single core cables
should be clamped by means of non-magnetic saddles. The saddles
shall not be placed at intervals more than 1500 mm. for horizontal and
1200 mm. for vertical runs.
3. Multicore control cables can be laid touching each other on cable
racks and wherever required may be taken in two layers. They
should be clamped by means of PVC straps both for horizontal
and vertical runs (alternatively, fabricated aluminium clamps may be
used) at regular intervals.
4. a) If the cables are buried directly in ground I.S. 1255 is to be followed
for code of practice. However, generally cables are laid 1000 mm.
below nished ground level at any point of cable run and 75 mm. of
sand cushioning to be provided.
4. b) In loose soil concrete pillar should be provided for as support and
hence pipes are recommended to the used for cable path.
5. If there is a possibility of mechanical damage, cables should be
protected by means of mild steel covers placed on racks.
6. While laying cables, special care to be taken at bends. Followings
are the recommended bending radius for power and control cables.
Voltage Rating KV
Upto 1.1 Above 1.1 but upto
11 K.V.
Above 11 K.V.

Where D is overall
diameter of cable.

PVC and XLPE Cables


Single Core
Multi Core
15 D
12 D
15 D
15 D
20 D
15 D

7.
Laying:
For laying of cables special cares to be taken to prevent sharp bending,
kinking, twisting. Cable should be unwound from drum by proper
mounting the cable drum on a cable wheel making sure the spindle
is strong enough to carry the weight without bending and that it is
lying horizontally in the bearings so as to prevent the drum creeping
to one side or the other while it is rotating.

Voltage grade
of cable
1.1 KV
3.3 KV
6.6 KV

Provision should be made to break the


drum to avoid further rolling & buckling
of cable during sudden stop. A simple
wooden plank can server this purpose

This is incorrect way of pulling the cable & will


cause kinks & twist in cable. Shall be avoided at all

Maximum safe pulling force (when pulled by pulling eye) Aluminium


Conductor Cables : 3.0 Kg/mm2 Copper Conductor Cables : 5.0
Kg/mm2 Proper method of pulling of cable should be used.
TESTING
INSULATION RESISTANCE MEASUREMENT OF CABLE
The voltage rating of I.R. Tester (Megger) should be chosen as following
table :

Cable must be
puled from the top

Rating of IR
Tester (Megger)
of cable
500 V
1000 V
1000 V

Voltage grade
of cable
11 KV
22 KV
33 KV

Rating of IR
Tester
(Megger)
1000 V
2500 V
2500 V

Testing during laying :


All new cables shall be megger-tested before jointing. After
jointing is completed all LV Cables shall be megger-tested.
End Terminations & Jointing :
Termination and jointing of Power & Control Cables shall be done
by means of compression methods using solderless tinned copper/
Aluminium terminal lugs. For control cables terminations, ring tongue or
reducer pin type terminal lug can also be used to suit the purpose.

Cable must be pulled accross hard &


sharp objects to avoid the damage to ve
covering & insulation
Cable must be laid in ducts or trenches
as shown in Fig.

Overhead/Outdoor Termination
XLPE insulation should be protected from direct solar rays or else ultra
violet resistant sleeving / tapping must be provided on exposed XLPE
insulation at the Termination to avoid degradation / cracking due to direct
exposer of solar rays.

However, following salient points are to be considered during laying


procedure of cables laid in racks and in built-in trenches.
1. For laying of cables power cables to be placed at the bottom most
layer and control cables at top most layer.
2. Single core power cable for use on A.C. system shall be laid in delta
formation supported by non-magnetic material. Trefoil clamps of
suitable size are to be placed at regular intervals but preferably not
more than 800 mm. Axial spacing of two circuits in delta formation
shall not be less than 4 times the cable dia.

SECTOR -1 GOVERNMENT ORGANIZATION


S. No.

Name of Customer

S. No.

Name of Customer

Engineers India Ltd

11

Department of Atomic Energy

NTPC

12

Airport Authority of India

NHPC

13

Electricity Department, UT Chandigarh

BHEL

14

NDMC

Power Grid Corporation of India Ltd.

15

EPIL

Steel Authority Of India

16

Electricity Department, Pondicherry

Eastern Railway, Fairlie Place, Kolkata

17

NTECL Vallor

Nuclear Power Corporation Ltd.

18

Aravali Power Corporation Ltd. (IGSTPP)

BEST Bombay

19

Durgapur Power Ltd.

10

Damodar Valley Corporation, kolkata

STATE ELECTRICITY BOARD


S. No.

Name of Customer

S. No.

Name of Customer

Jaipur Vidhyut Vitran Nigam Limited

19

Uttarkhand Power Corporation Ltd.

Jodhpur Vidhyut Vitran Nigam Limited

20

MVVNL, Lucknow

Rajasthan Rajya Vidhyut Vitran Nigam Limited

21

PUVVNL , Varanasi

Ajmer Vidhyut Vitran Nigam Limited

22

PVVNL, Meerut

Kerela State Electricity Board

23

DVVNL, Agra

Madhya Pradesh State Electricity Board

24

CPDCL of AP ltd, Hyderabad

Gujrat Energy Transmission Corporation ltd.

25

APGENCO of AP ltd, Hyderabad

Uttar Gujrat Vij company ltd.

26

EPDCL of AP ltd, Vishakhapatnam

Dakshin Gujrat Vij company ltd.

27

NPDCL of AP ltd, Warangal

10

Paschim Gujrat Vij company ltd.

28

DPDCL of AP ltd, Triputi

11

Madhya Gujrat Vij company ltd.

29

WBSECL

12

Maharastra State electricity Distribution Corporation ltd.

30

North Delhi Power Limited, New Delhi

13

Maharastra State electricity Generation Corporation ltd.

31

CESC Limited

14

Maharastra State electricity Transmisssion Corpn.

32

TANGEDCO

15

Uttar Haryana Bijli Vitran Nigam, Ltd.

33

BSES Limited

16

Dakshin Haryana Bijli Vitran Nigam, Ltd.

34

HPSEB

17

BESCOM , Bangalore

35

NTECL , Chennai

18

Noida Power Corporation Ltd.

SECTOR - 2 OIL & GAS CORPORATION


S. No.

Name of Customer

S. No.

Name of Customer

Indian Oil Corporation Ltd

10

MRPL , Mangalore

IOCL- PIPE LINE PROJECT

11

CPCL, Chennai

IOCL - REFINERY (8 Cities)

12

Boingaigaon Renery & Petro Ltd. Assam

Gas Authority of India Ltd.

13

Haldia Perto Chemicals

Bharat Petroleum Corporation Ltd.

14

Reliance Industries ltd.

Hindustan Petroleum Corporation Ltd.

15

Reliance Petroleum ltd.

Mittal Petroleum

16

Kochi Petroleum ltd.

Oil India Ltd.

17

ESSAR Oil

Numaligarh Renery Ltd.

SECTOR - 3 CEMENT
S. No.

Name of Customer

S. No.

Name of Customer

ACC cement

Aditya birla Cement

Amrit Cement

Adhunik Cement

Vicat Sagar Cement

Mysore Cement

Raghuram Cement

10

L & T Cement

Ultratec Cement

11

Grasim Cement

JP Cement

12

Shree Cement, Beawar, Ajmer

A view of dispatch yard

58

59

SECTOR - 4 CORPORATE HOUSES


S. No.

Name of Customer

S. No.

Name of Customer

Reliance Energy

JSW Steel

Jai Prakash Industries Ltd. , New Delhi

TATA Steel

Monenet Ispat & Energy Ltd.

10

VISA Steel

Grasim Industries Ltd.

11

INDUS BUILDWELL ltd.

Jindal Steel & Power

12

Schneider electric

BILT graphics paper products ltd.

13

Adani Group

Welspun, Mumbai

SECTOR - 5 EXPORT CUSTOMERS


S. No.

Name of Customer

S. No.

Name of Customer

Ethio Cement, Ethiopia

12

Evershine Electricals , Dubai

Mohan Exports

13

Yangaon Transformers, Myanmar

Angelique International,

14

UB Engineering, Dubai

A J Tronics Tanzania

15

Kinyara Sugar , Uganda

Inter Trade Commercial services TANESCO, Tanzania

16

A T Carter, Malawi

Afghan Solar, Afghanistan

17

Supereme Electricals, Kolkata (for Nigeria)

VEETEK Nigeria

18

Roongs & Rolling mills , Uganda

Nimra Jeddah Electric Est Saudi Arabia

19

Sameer Agriculture Kenya

True Liberty Electrical & Contracting Company, Kuwait

20

Saudi Electric Supply Company, Dammam, S.A.

10

African Commodities Dubai (for Nigeria)

21

Somotex Nigeria Ltd.

11

Sethi Brothers INC, Liberia

22

Somochem India Pvt. Ltd. (Ghane)

SECTOR - 6 EPC CONTRACTORS


S. No.

Name of Customer

S. No.

Name of Customer

ABB Limited

Alstom - Power Automation Systems

Larsen & Toubro - ECC

ESSAR Projects

Siemens

Sterling & Willson

Mcnally Bharat

10

Punj Lloyd

Sudhir Power projects Ltd.

11

Areva T & D Ltd.

A 2 Z maintainence and constuctions

12

Thyssenkrupp, Pune

SECTOR - 7 FERTILIZER
S. No.

Name of Customer

S. No.

Name of Customer

National Fertilizer Ltd.

IFFCO

ESSAR ( Fertilizer)

Kanpur Fertilizers

Matrix

60

Regional & Branch Ofces


NORTH - REGIONAL OFFICE:
Corporate Ofce : QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-4771000, Fax: 0120-4772000
Delhi:
Tel : 011-47676700, 23888200, Fax: 011-47676750, 23888250
Chandigarh:
Tel : 0172-4232400-401, Fax: 0172-4232403
Dehradun:
Tel: 0135-6670202, Fax: 0135-6670203
Noida / Haryana: Tel: 0120-4771000, Fax: 120-4772000
Ludhiana:
Tel: 0161-4676001 / 6024, Fax: 0161-46766007
Jammu:
Tel: 0191-2490424, Fax: 0191-2490405
Sri Nagar:
Telefax: 0194-2490431
Jaipur:
Tel: 0141-3988210, Fax: 0141-2389024
Jodhpur:
Tel: 0141-3914645, 3988210
Lucknow:
Tel: 0522-2201032, 2200938
Kanpur:
Tel: Airtel: 09935533751/52/53, 0512-2690128/129/130, Fax: 0512-2692800

EAST - REGIONAL OFFICE:


Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52, Fax: 033-40127339
Bhubaneshwar: Tel: 0674-2598104, 2598105, 2598106, Fax: 0674-2598107
Guwahati:
Tel: 0361-2134521, 2458923, Fax: 0361-2460355
Siliguri:
Tel: 0353-2525907, Fax: 0353-3290402 (RIM)
Jamshedpur:
Tel: 0657-6542492, 09234369436
Patna:
Tel: 0612-2207221, 2207222, 2207223, Telefax: 0612-2655518

WEST - REGIONAL OFFICE:


Mumbai: 301, Everest House, 3rd Floor, 6, Suren Road, Chakala, Andheri (E). Mumbai - 400 093,
Tel: 022-67298600-602 & Fax: 022- 67298603-604
Ahmedabad:
Tel: 079-40061111, 40060738-740, Fax: 079-40060741
Indore:
Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626
Rajkot:
Tel: 0281-2481112, 2921212, Fax: 2481112
Nagpur:
Tel: 0712-2224132, 2222692, 2222029
Pune:
Tel: 020-64016413 / 14
Raipur:
Tel: 0771-4243400 / 01, Telefax: 0771-4243402
Surat:
Tel: 09979890137, Telefax: 0261-2350137
Jabalpur:
Tel: 0761-4064491

SOUTH - REGIONAL OFFICE:


Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008,
Tel: 044-42280600, 605, Fax: 044-28524326
Bangalore:
Tel: 080-49075000, 9844085913, Fax: 080-25582663
Coimbatore:
Telefax: 0422-2305767, 2306199, 2305199
Hyderabad:
Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Fax: 040-27533211
Kochi:
Tel: 0484-4099000, Fax: 0484-2393170
Vishakapatnam:
Vizag:
Vijayawada:
Calicut:
Madurai:
Trivandrum:
Hubli:
Trichy:

Tel:
Tel:
Tel:
Tel:
Tel:
Tel:
Tel:
Tel:

0891-6514339, Fax: 0891-2522547


0891-6514339, Fax: 0891-25522547
91+9247058847/57
09895855499
09994493242
09633817795
09448146028
09944460160

2EPRESENTATIVE/FlCESs'OAs3OLAPURs'WALIORs+ATHMANDUs"HOPAL

CAB/ZHCMC00002/MAR13/MAY13

Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication.
Specications and performance data are constantly changing. Current details should therefore be checked with Havells Group.

Havells India Ltd.


Corp Ofce: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-4771000,
E-mail: [email protected], www.havells.com
Consumer Care No.: 1800 103 1313 (All Connections), 011-4166 0303 (Landline)
Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!

You might also like