Diagnostic Ultrasound System MODEL: PROSOUND α7

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Diagnostic Ultrasound System MODEL: PROSOUND 7

Real-time Tissue Elastography is a registered trademark or trademark of Hitachi Medical Corporation in Japan and other countries. The specifications, shape and color of this product are subject to change without notice. The standard components and optional items vary depending on the country.

We strive to provide quality products and services for our customers. We operate with regard for the environment.

6-22-1, Mure, Mitaka-shi, Tokyo, 181-8622 Japan Telephone : +81 422 45 6049 Facsimile : +81 422 45 4058 www.hitachi-aloka.com

3 (K) Printed in Japan 2011-12 E292-3

Powerful, Friendly and Compact Ultrasound System

Specialized Throughout the Hospital


With outstanding versatility, ProSound 7 is ready for a broad range of clinical applications as a specialized system.

OB/GYN

Breast Ultrasound

Powerful
ProSound 7 inherits the proven technologies and functions of our high-end model. The high quality images allow for reliable and efficient examination.

Friendly
User friendly, patient friendly and environment friendly; this is the premium feature of the ProSound 7. The universal design enables the system to fit your every need and improved efficiency reduces burden on the patient. The system is also environmentally-friendly, made of ecological materials and having low power consumption.

Compact
Can systems with high performance be compact? ProSound 7 has proven this possible. The compact and light-weight system can easily be moved throughout the hospital; examination rooms, ICU, operating theater, or patients bedside, delivering high-quality examinations.

Cardiology Vascular OB/GYN Breast Ultrasoun OB/GYN Breast Ultrasound Urology Abdominal Cardiology Vascular OB/GYN Breast Ultraso Cardiology Vascular OB/GYN Breast Ultrasound Intraoperative Interventional Urology Abdominal Cardiology Vascular OB/GYN Breast Ultrasound Urology Abdominal OB/GYN Breast Ultrasound Cardiology Vascular Musculoskeletal Anesthesiology Intraoperative Interventional Urology Abdominal Cardiology Vascular Cardiology Vascular OB/GYN Breast Ultrasound Intraoperative Interventional Urology Abdominal Pediatrics Small Parts OB/GYN Breast Ultrasound Musculoskeletal Anesthesiology Intraoperative Interventiona Urology Abdominal OB/GYN Breast Ultrasound Cardiology Vascular Urology Abdominal Musculoskeletal Anesthesiology Intraoperative Interventional Cardiology Vascular OB/GYN Breast Ultrasound Many more . Parts .. Pediatrics Small Musculoskeletal Anesthesiolog OB/GYN Breast Ultrasound Cardiology Vascular Intraoperative Interventional Urology Abdominal Intraoperative Interventional Pediatrics Small Parts Musculoskeletal Anesthesiology Cardiology Vascular Urology Abdominal Many more ... Pediatrics Small Parts Cardiology Vascular Urology Abdominal Musculoskeletal Anesthesiology OB/GYN Breast Ultrasound Intraoperative Interventional Musculoskeletal Anesthesiology Pediatrics Small Parts Urology Abdominal Intraoperative Interventional Many more ... Cardiology Vascular Abdominal Many more . . Urology Intraoperative Interventional Pediatrics Small Parts Musculoskeletal Anesthesiology Pediatrics Small Parts Intraoperative Interventional Musculoskeletal Many more Anesthesiology ... Urology Abdominal IntraoperativeSmallAnesthesiology Interventional Musculoskeletal Pediatrics Parts Many Musculoskeletal Anesthesiology Many more .Parts . . more . . . Pediatrics Small
Intraoperative Interventional

Musculoskeletal Anesthesiology Pediatrics Small Parts Musculoskeletal Anesthesiology Many more . . Parts . more . . . Pediatrics Small Many
Pediatrics Pediatrics Small Parts Small Many more . . .

Parts Many more . . .. . . Many more Many more . . .


3

Exceptional Image Quality for Your Diagnostic Confidence

With the latest technologies and years of experience, ProSound 7 is ready for your clinical needs. High versatility and specialized functions provide outstanding images with impressive contrast and spatial resolution. With high S/N ratio and reduced side lobes, this system presents you with all the information you need for confident diagnosis.

eFLOW Dynamic, detailed blood ow display


eFLOW features enhanced spatial resolution for greater detail. Blood flow can be displayed separately from tissues with only minimal overlapping. Slow blood flow in the finest peripheral vessels such as in fingertips and fast flows in the largest great vessels can dynamically be observed together in one image.
Renal blood flow, clearly displayed to the very minute vessels

Broadband Harmonics (BbH)


High penetration and spatial resolution co-exist in both fundamental and Harmonic Echo imaging, using broadband transmission. Making full use of the second harmonic that reduces side lobes and multiple echoes, Broadband Harmonics offers exceptional clarity on the entire image.

Adaptive Image Processing (AIP) Clearer edge denition


Differences in tissues can be clearly displayed with reduced speckle noise using AIP. Even clearer edges are delineated by selectively emphasizing boundaries. Operating while maintaining the frame rate, AIP is also beneficial in cardiac observations.

Aorta, displayed with clear edges

Spatial Compound Imaging (SCI) Sharper depiction of luminal structure


SCI enhances depiction of side wall structures of lumens by superimposing images acquired by steering ultrasound beams in multiple directions. Speckle patterns in parenchymal organs are more finely displayed, and artifacts depending on beam direction are reduced.
Carotid Artery, with clear cut vessel walls

Trapezoidal Scan
Images scanned by linear probes can be displayed with a wider field of view, in a trapezoidal form.

Ordinary linear scan

Trapezoidal scan

Womens Healthcare
Gently Supporting the Wellness of Mother and Baby

Spatio-temporal Image Correlation (STIC)


Complete 3D volume data set of one heartbeat of the fast moving fetal heart can be constructed, enabling MPR display in a moving image.

Real-time Tissue Elastography


Stiffness of tissues can be visualized in real time. Using Strain Ratio Measurement to calculate the ratio of 2 areas of your choice, the ratio of stiffness between fat and region of interest (FLR: Fat Lesion Ratio) can be obtained.

Multi-follicle Volume (MFV)


Multiple follicles can automatically be detected in 3D, and the diameter and volume of each follicle can be displayed.

Dynamic Slow-motion Display (DSD)


While displaying a real-time image on the left, its slow motion image can be displayed on the right side of the screen. Each movement of fast moving fetal heart with complex structure can be caught, and details can be examined.
Real-time Slow motion Easy understanding of follicles using MFV
Courtesy of: Dr. Chen, Nanfang Hospital, Southern Medical University

Image of the breast

Small part 3D Imaging


High resolution volume data of superficial areas such as the breast can be acquired using the high-frequency linear 3D probe.

eFLOW
The high resolution eFLOW faithfully presents blood flow in minute vessels, without overlapping of color on the tissue.

Volume Slice Imaging (VSI)


Displaying cross-sectional images with thickness, VSI improves image quality by enhancing contrast resolution and reducing speckle noise, and enables easier 3D understanding of the target.

Detailed image of the fetal brain using VSI

Courtesy of: Prof. WANG Yi, Huashan Hospital, Fudan University, Shanghai, China

Automated Nuchal Translucency (NT) Measurement


Automated NT Measurement automatically detects and measures NT thickness. Set the region of interest (ROI) on the fetal necks mid-sagittal view, and the ProSound 7 will do the rest. This easy, quick and efficient function supports accurate diagnosis of chromosomal abnormalities such as Down syndrome.
Courtesy of: Dr. Marc Althuser, France

Breast image of lesion pulling in its surrounding tissues, using VSI

Precise reproduction of the uterine artery

Real-time 3D (4D) fetal image

3D display of blood flow in the umbilical cord using Flow 3D

The fetal aorta using Multi-slice Imaging (MSI)

Cardiovascular
From Prevention to Diagnosis to Treatment Quantitative Analysis Entirely Supports You

Early stage before organic change occurs Evaluations of endothelial function and arterial stiffness

Onset of organic change Measurements of IMT, flow velocity, and stenosis

Onset of angina pectoris or myocardial infarction

Treatment phase Contribution to Cardiac Resynchronization Therapy (CRT)

Evaluation of Ischemic Cascade

eTRACKING (Echo Tracking)


The tracking gate automatically follows vessel wall movements, measuring vessel diameter change in real time at an exceptional accuracy of 0.01 mm.

Automated Intima-media Thickness (IMT) Measurement


Simply by setting the ROI on a vessels longitudinal image, max and mean IMTs can be automatically computed.

Automated Segmental Motion Analysis (A-SMA)


Cardiac wall movements can be quantitatively evaluated from changes in the areas of each cross section of cardiac chambers, by the automatically traced endocardiums.

TDI (Tissue Doppler Imaging) Analysis


For further evaluation of regional cardiac functions, we focused on cardiac movements from the myocardia. Strain/ Strain Rate, which is hardly influenced by tethering or translation, is becoming more and more recognized.

Arterial Stiffness
Parameters necessary for quantitative evaluation of early stages of atherosclerosis can be computed at once and displayed on the report. Such parameters include Beta and Ep values, Arterial Compliance (AC), Augmentation Index (AI), and one-point PWV.

Strain Analysis using TDI

CW Doppler by the Linear Probe


Faster blood flows can now be observed with the linear probe without having to change to a sector probe. Stenotic blood flow in superficial areas can sensitively be detected, with excellent image quality and wide field of view.

Histogram display in systole

Free Angular M-mode (FAM)


In one hear tbeat, cardiac wall motion in multiple areas and valves can be compared.

Stress Echo
With easy operation, exercise stress and pharmacological stress examinations can be performed. Simultaneous display of multiple moving images of before and after stress application contributes to evaluations of ischemia and myocardial viability.

Flow Mediated Dilatation (FMD)


Noninvasive method for evaluating the vascular endothelial function.
Courtesy of: Saitama Medical University International Medical Center Tetsuya Yamamoto Makoto Matsumura

FAM, analyzing 3 points

Asynchrony Measurement
Various parameters necessary for dyssynchrony evaluation of between ventricle and atrium, the two ventricles, or within a ventricle are provided as one study.

Transit Time of Vessel Flow (TVF)


TVF is an index for estimating stenosis and occlusion in the artery of the lower extremities. The time it takes from R wave to the peak of each blood flow waveform in 3 arteries of the lower limb, common femoral artery, popliteal artery, and ankle are automatically measured and the left-right difference is compared.

Asynchrony measurement report

Patient Friendly Trans-esophageal Probes


Our trans-esophageal probes are designed for patient comfort, maintaining excellent image quality and features in the amazingly fine probe shape.

4.8 mm diameter

Wave Intensity (WI)


This hemodynamic index is expected to be beneficial for analyzing interaction between the heart and the vascular system.

Neonatal probe Pediatric rotary plane probe Rotary plane probe

Actual size

UST-5293S-5 Rotary plane probe

UST-52110S Super fine probe for neonates

Abdomen/Digestive Organs
High-denition Imaging Broadband Harmonics (BbH) eFLOW

Musculoskeletal/Rheumatology
Ultrasound examinations are becoming more and more popular in the musculoskeletal and rheumatologic fields.
Power Doppler Freehand 3D (MSI display)

Courtesy of: Hokkaido Medical Center for Rheumatic Diseases

High penetration and spatial resolution image of abscess in the liver

Dilatation of intrahepatic bile duct with detailed depiction of blood flow

Joint Rheumatology
Bone erosion, synovial thickening, and synovial blood flow can easily be observed by simply placing the probe on your patient, over the targeted area. Quantification examinations obtained from the ratio of areas with color and without have been attracting attention as a way to evaluate disease activity.

Fluid in the Knee Joint


With Freehand 3D, volume data can be obtained with a 2D probe. Observing volume data using Multi-slice Imaging (MSI) enables easy understanding of lesion spread.

3D Imaging Multi-planar Reconstruction (MPR) Multi-slice Imaging (MSI)

High-frequency Linear Probe

Extended Field of View (EFV)

Bladder tumor, viewed from multiple planes and in 3D

Multi-planar parallel display of the kidneys 3D volume data Clear depiction of the humeroradial joint Wide view of the lower extremity

Contrast Echo
Supports all types of contrast agents of high to low acoustic pressures.

Dual Dynamic Monitor (DDM)


A fundamental image and its contrast enhanced image can be displayed side by side, in real time, simultaneously.

Micro-convex Probe
With the micro convex probe that fits in narrow intercostal windows, safer puncturing is possible with very minimal blind areas. This is advanta geous in contrast echo evaluation before and after RFA treatment.

Intraoperative
Real-time Tissue Elastography Real-time Tissue Elastography

Case of hepatic hemangioma, before right hepatectomy. Displayed with marginal strong echo. Probe used: intra-operative probe, UST-9132T

Image of metastatic hepatic cancer

Courtesy of: Dr. Yosuke Inoue & Professor Norihiro Kokudo, Graduate School of Medicine, University of Tokyo

Strain Ratio Measurement of the liver

Courtesy of: Professor Keiji Sano, Professor of Surgery, Teikyo University School of Medicine

10

11

Abundant optional probes


As many as 50 types of optional probes, including those for routine examination and specialty use, are available.

General abdomen Transvaginal Transrectal Intraoperative Small parts Biopsy Cardiology Transesophageal Laparoscopic Endoscopic ultrasound

Laparoscopic probe

Intercostal biopsy

Intraoperative (finger-grip type)

Bi-plane trans-rectal probe

Abdominal biopsy

Intraoperative (finger-grip type)

Endoscopic Ultrasound (Manufactured by Olympus Medical Systems)


Convex scanning bronchobervideoscope
Specifically designed for real-time endobronchial ultrasound guided transbronchial needle aspiration(EBUS-TBNA). With high resolution image quality and high sensitivity Color Doppler, the system allows for safer and more accurate biopsy in the mediastinal and hilar lymph nodes for the diagnosis and staging of lung cancer.

Radial scanning scope


The radial scanning scope covers a wide 360-degree ultrasound scanning range and supports early detection and staging of diseases. This system is equipped with Color Doppler function that is useful for differentiating blood vessels from lymph nodes by displaying moving objects with color. This function also enables easier orientation in the pancreatobiliary region.

Convex scanning scope


The convex scanning scopes are designed mainly for endoscopic ultrasound-guided fine needle aspiration. A wide 180-degree ultrasound scanning range and Color Doppler function enable differentiation between blood vessels and lymph nodes and ensure comprehensive imaging of all structures surrounding the region of interest.

Notes:The above endoscopes are not marked in some countries and areas. Marketable models are different from the above in some countries and areas.

12

13

Comfortable Examination and Working Environment The result of our efforts towards usability

How to Streamline your Workflow


You provide directions; let the automating functions do the rest Image Optimizer
In addition to the ordinary B-mode Gain, STC settings in the depth and lateral Gain can also be optimized in one action. As the system learns the examiners adjustment trends, it will grow to deliver images of your preference as more and more examinations are performed.

Before optimizing

Optimized

Doppler Auto Trace, Auto IMT Measurement, TDI Auto Trace function
Automated measurements not only shorten exam time but enhance accuracy, obtaining definite results regardless of the examiner.

Protocol Assistant
With the Protocol Assistant, the system will guide you through your exam, preventing forgetting to capture or measure images. Pre-register the steps and they will be displayed on the touch panel with a body mark, measurement name, and annotation. As images are printed or stored along the protocol, checkmarks will appear in the checkboxes automatically. When exams are interrupted, a warning message will appear to ensure that the entire examination is performed.

Remote Controller
Have you ever felt the need to reach the operation panel but was difficult to do so, such as when examining the lower extremities or when using a TEE probe? The ProSound 7 brings the small, simplified operation panel right in your hand as a remote controller. Looking for switches is unnecessary, as functions are selected from the monitor on the system.

Operation panel with your switch layout


Most panel switches are customizable to match your needs, with replaceable key tops.

10.4 inch large touch panel


Able to customize the menu layout in a format most useful for you.

Small is good.
Looking for a place to t your system?
The footprint of ProSound 7 is only 49 cm x 79 cm, compact and easy to fit in small spaces.

Flexible monitor with handle


The monitor alone can be swiveled horizontally and slid vertically. With the monitor and operation panel moving individually, each can be set to their optimal positions.

Adjustable panel height and angle for your ease of use


Short or tall, standing or sitting; you name the height, and ProSound 7 will adjust to it. The operation panel can also be swiveled for you to scan in comfort.

Move your ProSound 7 throughout the hospital.


With the four swivel casters, this system is easy to move with tight turns. Swiveling of the casters can be locked for easier transportation when moving straight without drifting.

14

15

You might also like