Content Sheet 10-1: Overview of External Quality Assessment (EQA)

The document discusses external quality assessment (EQA) and its role in quality management systems for laboratories. It defines EQA as using an external agency to objectively check a laboratory's performance. Common EQA methods include proficiency testing where unknown samples are sent to laboratories for testing and comparison, rechecking samples that have already been analyzed, and on-site evaluations. EQA provides benefits like allowing performance comparisons, identifying problems or training needs, and helping assure customers of reliable results. Laboratories must carefully follow EQA instructions and use the feedback to make improvements.

Uploaded by

Prabhu Selvaraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views12 pages

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

The document discusses external quality assessment (EQA) and its role in quality management systems for laboratories. It defines EQA as using an external agency to objectively check a laboratory's performance. Common EQA methods include proficiency testing where unknown samples are sent to laboratories for testing and comparison, rechecking samples that have already been analyzed, and on-site evaluations. EQA provides benefits like allowing performance comparisons, identifying problems or training needs, and helping assure customers of reliable results. Laboratories must carefully follow EQA instructions and use the feedback to make improvements.

Uploaded by

Prabhu Selvaraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Role in quality management system

Assessment is a critical aspect of laboratory quality management, and it can be conducted in several ways. One of the commonly employed assessment methods is that of external quality assessment.

Organization

Personnel

Equipment

Purchasing & Inventory

Process Control

Information Management

Documents & Records

Occurrence Management

Assessment

Process Improvement

Customer Service

Facilities & Safety

Definition of EQA

The term external quality assessment (EQA) is used to describe a method that allows for comparison of a laboratorys testing to a source outside the laboratory. This comparison can be made to the performance of a peer group of laboratories or to the performance of a reference laboratory. The term EQA is sometimes used interchangeably with proficiency testing; however, EQA can also be carried out using other processes. EQA is here defined as a system for objectively checking the laboratorys performance using an external agency or facility.

Types of EQA

Several EQA methods or processes are commonly used. These include: 1. Proficiency testingexternal provider sends unknown samples for testing to a set of laboratories, and the results of all laboratories are analyzed, compared, and reported to the laboratories. 2. Rechecking or retestingslides that have been read are rechecked by a reference laboratory; samples that have been analyzed are retested, allowing for inter-laboratory comparison.

External Quality Assessment Module 10 Content Sheet

3. On-site evaluationusually done when it is difficult to conduct traditional proficiency testing or to use the rechecking/retesting method. Another method of inter-laboratory comparison is the exchange of samples among a set of laboratories, usually reserved for specialized tests for which no proficiency testing is available. This method is used either by very specialized or sophisticated laboratories and therefore will not be further discussed in this module.
EQA benefits

Participation in an external quality assessment program provides valuable data and information which: allows comparison of performance and results among different test sites; provides early warning for systematic problems associated with kits or operations; provides objective evidence of testing quality; indicates areas that need improvement; identifies training needs.

EQA helps to assure customers, such as physicians, patients, and health authorities, that the laboratory can produce reliable results. Individual laboratories can use EQA to identify problems in laboratory practices, allowing for appropriate corrective action. EQA participation will help to evaluate reliability of methods, materials, and equipment, and to evaluate and monitor training impact. For laboratories performing public health-related testing, EQA can help to assure that results from different laboratories during surveillance activities are comparable. EQA participation is usually required for accreditation. Also, EQA participation creates a network for communication, and can be a good tool for enhancing a national laboratory network. Samples received for EQA testing, as well as the information shared by the EQA provider, are useful for conducting continuing education activities.
Principal EQA programs vary but principal characteristics include the following: characteristics EQA programs can either be free-of-charge or require a fee. Free EQA of an EQA programs include those offered by a manufacturer to ensure equipment is scheme

working correctly and those organized by a regional or national program for quality improvement.

External Quality Assessment Module 10 Content Sheet

Some EQA programs are obligatory, either required by an accrediting body or by law. Others are voluntary, and the quality manager may choose to voluntarily participate in an EQA program in order to achieve improvement in the quality of the laboratorys performance. The EQA program can be organized at different levels: regional, national, or international. Individual laboratory results are kept confidential, and generally are only known by the participating laboratory and the EQA provider. A summary is generally provided and allows comparison to the overall group. Some EQA schemes may address a single disease, for example the EQA program for tuberculosis. Others may address many kinds of laboratory tests, looking at the overall testing performance for microbiology. An example of this multi-disease or test program is the national microbiology EQA in France, which is obligatory. Successful performance in an EQA program reflects the effectiveness of the laboratorys quality management, and allows for recognition of laboratory quality by external groups.

EQA is important for improvement of the laboratory quality management system, as it is a measure of laboratory performance.

External Quality Assessment Module 10 Content Sheet

Content Sheet 10-2: Proficiency Testing


Definitions

Proficiency testing, or PT, has been in use by laboratories for many years. It is the most commonly employed type of EQA, as it is able to address many laboratory methods. Proficiency testing is available for most of the commonly performed laboratory tests, and covers a range of chemistry, haematology, microbiology, and immunology testing. Most laboratorians are familiar with the proficiency testing process, and many laboratories employ some kind of proficiency testing. Standards organizations recognize the importance of this tool, and the following are examples of formal definitions that are in use. ISO/IEC Guide 43-1:1997: Proficiency testing schemes (PTS) are interlaboratory comparisons that are organized regularly to assess the performance of analytical laboratories and the competence of the analytical personnel. CLSI: A program in which multiple samples are periodically sent to members of a group of laboratories for analysis and/or identification; whereby each laboratorys results are compared with those of other laboratories in the group and/or with an assigned value, and reported to the participating laboratories and others.

Proficiency testing process

In the proficiency testing process, laboratories receive samples from a proficiency testing provider. This provider may be an organization (non-profit or for-profit) formed specifically to provide PT. Other providers of proficiency testing include central reference laboratories, government health agencies, and manufacturers of kits or instruments. In a typical PT program, challenge samples are provided at regular intervals. An optimal frequency will be 34 times yearly. If the program cannot provide challenges with this frequency, the laboratory may be able to seek additional sources. The laboratories participating in the program analyze the samples and return their results to the central organization. Results are evaluated and analyzed, and the laboratories are provided with information about their performance and how they compared with other participants. The participating laboratories use the information regarding their performance to make appropriate changes and improvements.

Roles of laboratory

To be successful, PT instructions must be followed carefully, all paper work completed accurately, and results submission deadlines met. All PT results, as well as corrective actions, should be recorded and the records maintained for an appropriate period of time. PT is a tool to measure laboratory performance. Therefore, there must be no difference in the treatment of PT samples and the patients sample. Proficiency

External Quality Assessment Module 10 Content Sheet

testing providers make every effort to produce samples that exactly mimic, or closely resemble, usual samples received from patients. PT samples must be processed by normal testing method(s) and involve personnel who routinely perform the testing. When PT is used for any purpose other than internal quality improvement, the provider or central organization generally prohibits the discussion of results with other laboratories. Some PT organizers send different samples to different groups of laboratories to avoid inter-laboratory discussion. Nothing is gained from PT participation unless the information received is directed to improvement in the laboratory.

Limitations

It is important to remember that PT does have some limitations and it is not appropriate to use PT as the only means for evaluating the quality of a laboratory. PT results are affected by variables not related to patient samples, including preparation of the sample, matrix effects, clerical functions, selection of statistical methods of evaluation, and peer group definition. PT will not detect all problems in the laboratory, particularly those that address the pre- and post-examination procedures. A single unacceptable result does not necessarily indicate that a problem exists in the laboratory.

External Quality Assessment Module 10 Content Sheet

Content Sheet 10-3: Other EQA Methods


Using other EQA methods

In situations where it is difficult to provide appropriate external samples, or sometimes, when normal laboratory quality control methods cannot be applied, other procedures have been developed and used for EQA. The primary examples, and their uses, are as follows. Rechecking/retesting has been used traditionally for EQA for microscopic slides for acid-fast bacilli (AFB), and for human immunodeficiency virus (HIV) rapid testing. It can also be used in other situations, but is not usually employed if traditional PT is feasible. On-site evaluation has proven a useful technique for the same situationsAFB examination and HIV rapid testing. It allows for an external evaluation of quality on-site, and can be conducted in conjunction with proficiency testing or rechecking/retesting.

These procedures can be time-consuming and costly, and so are used only when there are not good alternatives. It is essential to have a reference laboratory with the capacity to do the repeat testing; the use of a reference laboratory gives assurance that the re-examination process will give a dependable result. The turnaround for the retesting must be accomplished in a timely manner allowing for immediate corrective actions. In some settings, transport of samples or slides to the reference laboratory will present problems.

Retesting process

This EQA method is used for HIV rapid testing. HIV rapid testing presents some special challenges, because it is often performed outside a traditional laboratory, and by persons who are not trained in laboratory medicine. Additionally, the kits are single-use, and cannot be subjected to the usual quality control methods that laboratories employ. Therefore, retesting of some of the samples using a different process such as enzyme immunoassay (EIA) or ELISA (enzyme-linked immunosorbent assay) helps to assess the quality of the original testing. Characteristically, the retesting is: done by a reference laboratory, to ensure quality; performed on dried blood spots or serum collected at the time of the rapid test performance; not performed as a blinded process, as this is unnecessary.

External Quality Assessment Module 10 Content Sheet

The number of samples retested must provide statistically significant data in order to detect error. This becomes difficult in settings where small numbers of rapid tests are performed. A full discussion of the statistical issues in retesting is found in the CDC/WHO reference Guidelines for Assuring the Accuracy and Reliability of HIV Rapid Testing: Applying a Quality System Approach.
Rechecking process

This method is most commonly used for acid-fast smears; the slides that were read in the original laboratory are rechecked in a central or reference laboratory. This allows for the accuracy of the original report to be evaluated, and also allows for the assessment of the quality of the slide preparation and staining. The following principles are important when performing recheck procedures. The slides for re-examination must be collected randomly. Every effort should be made to avoid systematic sampling bias. Rechecking must be based upon statistical considerations. A common method is for the central laboratory to recheck 10% of negative and 100% of positive slides. When discrepancies occur, there should be procedures in place to resolve them. The outcome of rechecking must be analyzed for effective and timely feedback.


Advantage of performing blind recheck

It is usually recommended that rechecking be done in a blinded fashion, so that the laboratorian performing the retest does not know the original results. In the study described in Annex 10-A (and shown in Presentation 10, Slide 20), random blinded rechecking provided more accurate estimates of AFB microscopy results than on the non-randomly selected, non-blinded smears. This resulted in improved diagnosis and monitoring of treatment response. A periodic visit by evaluators for on-site laboratory assessment is a type of EQA that has been used when other methods of EQA are not feasible or effective. Again, this method has most frequently been employed for assessment of sites performing AFB smears, and those performing HIV rapid testing. On-site evaluation can be a valuable tool to: obtain a realistic picture of laboratory practices by observing the laboratory under routine conditions in order to check that it is meeting quality requirements;

On-site evaluation

External Quality Assessment Module 10 Content Sheet

provide information for internal process improvement; measure gaps or deficiencieslearn where we are; assist the laboratory in collecting information for planning and implementation of training, monitoring, and corrective actions.

On-site evaluation for the purpose of EQA may be conducted by a central reference laboratory or other health authorities. On-site evaluation can be used together with retesting and rechecking schemes to provide more information about performance.

External Quality Assessment Module 10 Content Sheet

Content Sheet 10-4: Comparison of EQA Methods


Some of the characteristics of proficiency testing and rechecking are compared in the table below. Comparison of proficiency testing (PT) and rechecking/retesting (RC) Method/characteristics Interlaboratory comparison Simulated samples Real samples Time and resources needed Analytes evaluated PT Yes Yes Yes/No Less Many RC Yes No Yes More Few

Comparison of some characteristics

Summary of comparison

Proficiency testing: gives a good, objective measure of the laboratory performance; can be organized to address most kinds of laboratory testing; is cost-effective and can therefore be used frequently.

Retesting / rechecking: is useful when it is difficult or impossible to prepare samples to test all of the testing process; is expensive and uses considerable staff time.

On-site evaluation: can give a true picture of a laboratorys overall performance, and offer realtime guidance for improvements that are needed; is probably the most costly, requiring staff time and travel time and expenses of those performing the evaluation.

External Quality Assessment Module 10 Content Sheet

Content Sheet 10-5: Managing EQA in the Laboratory

Participation in EQA

All laboratories should participate in EQA challenges, and this should include EQA for all testing procedures performed in the laboratory, if possible. The benefits of this participation are considerable, and EQA provides the only means available to a laboratory to ensure that its performance is comparable to that of other laboratories. For laboratories that are accredited, or that plan to seek accreditation, EQA participation is essential. ISO 15189 addresses EQA requirements for laboratories as follows. There is a requirement that the laboratory participate in interlaboratory comparisons. Where an established EQA scheme is not available, an alternate EQA mechanism will have to be considered for interlaboratory comparison such as exchange of samples with other laboratories. The laboratory management shall monitor the results of EQA and participate in the implementation of corrective actions.

Management process

When participating in EQA programs, the laboratory needs to develop a process for the management of the process. A primary objective is to assure that all EQA samples are treated in the same manner as other samples tested. Procedures should be developed. Handling of samplesThese will need to be logged, processed properly, and stored as needed for future use. Analyses of samplesConsider whether EQA samples can be tested so that staff do not recognize them as different from patient samplesblinded testing. Appropriate record keepingRecords of all EQA testing reporting should be maintained over a period of time, so that performance improvement can be measured. Investigation of any deficienciesFor any challenges where performance is not acceptable. Taking corrective action when performance is not acceptableThe purpose of EQA is to allow for detection of problems in the laboratory, and to, therefore, provide an opportunity for improvement. Communication of outcomes to all laboratory staff and to management.

External Quality Assessment Module 10 Content Sheet

10

EQA performance problems

If the laboratory performs poorly on EQA, the problems may lie anywhere along the path of workflow. All aspects of the process will need to be checked. Some examples of problems that may be identified include the following. Pre-examination The sample may have been compromised during preparation, shipping, or after receipt in the laboratory by improper storage or handling. The sample may have been processed or labeled improperly in the laboratory. The EQA challenge materials may exhibit a matrix effect in the examination system used by the participating laboratory. Possible sources of analytical problems include reagents, instruments, test methods, calibrations, and calculations. Analytical problems should be investigated to determine whether error is random or systemic. Competency of staff will need to be considered and evaluated. The report format can be confusing. Interpretation of results can be incorrect. Clerical or transcription errors can be sources of error.

Examination

Post-examination

Incorrect data captured by the EQA provider is another possible source of error.

External Quality Assessment Module 10 Content Sheet

11

Content Sheet 10-6: Summary


Summary

EQA is a system for objectively checking the laboratorys performance using an external agency or facility. All laboratories should participate in an EQA process for all tests performed, whenever possible. Accredited laboratories are required to participate in EQA. There are several methods for conducting EQA; traditional proficiency testing is available for many tests, is cost-effective, and provides useful information. When proficiency testing is not practical or does not provide enough information, other methods should be employed. There must be no difference in the treatment of a proficiency testing sample and a patient sample. The normal testing methods must be followed and the procedure must involve personnel who routinely perform the testing.

Key messages

As EQA uses valuable resources, the laboratory should make the best use possible of its participation in EQA. EQA should not be punitive. It should be viewed as educational and used as a tool to help direct improvement efforts in the laboratory. EQA is one of the critical elements of a laboratory quality management system.

External Quality Assessment Module 10 Content Sheet