Micro Hardness Testing Machines: Index
Micro Hardness Testing Machines: Index
Micro Hardness Testing Machines: Index
Testing Machines
Rockwell Hardness
Testing Machines
Portable Hardness
Testing Instruments
Vickers Hardness
Testing Machines
K-1
Test Equipment
INDEX
Micro Hardness Testing Machines
Lineup of Hardness Testing Machines K-2, 3
HM-101/112/113/122/123 K-4
HM-114/115/124/125 K-5
HM-211/221 K-6
AAV-500 K-7
MZT-500 K-8
HV-112/113/114/115 K-9
Optional Accessories K-10, 11
Rockwell Hardness Testing Machines
HR-521/523 K-12
AR-20, ARK-600/601, ATK-600/601 K-13
Optional Accessories K-14, 15
Portable Hardness Testing Instruments
Hardmatic HH-300 K-16, 17
Hardmatic HH-411 K-18
Servo Type Acceleration Pickup
MicroAccel V407-3-AT K-19
V405 K-19
Piezoelectronic Type Acceleration Pickup
V300 K-20
Electrokinetics-Type Acceleration Pickup
V200 and U1 K-21
Non-Contact Displacement Pickup
V460 K-22
Data Logger
GPL-02 K-22
Handy Vibrometer
AHV-1000AZ K-23
AHV-1000BU K-23
AHV-11A K-24
Universal Vibrometer
AVT-CZ K-25
AVT-B2 K-25
AVT-3000DZ K-26
AVT-103/AVT-104 K-26
AVT-SB K-27
AVT-PS K-27
Vibration Monitoring Machine
AVR Series K-27
Vibration Pickup Servo
Type Acceleration Pickup
Data Logger
Vibrometer
Universal Vibrometer
K-2
Microhardness
(Micro-Vickers)
Micro surface material
characteristics
Vickers
Rockwell
Rockwell Superficial
Rebound type
portable
For sponge, rubber,
and plastic
Hardness testing machines provide the
simplest and most economical testing
methods among many material testing
machines, playing an important role in
research activities, production activities,
and commercial transactions. Mitutoyo
offers a choice of standard hardness
testing machines that are optimal for hard
materials such as metals to soft materials
such as plastic and rubber, as well as
custom-designed testers such as in line-
type automatic machines and labor-saving
machines required on the shop oor.
Lineup of Hardness Testing Machines
K-3
136
d
d
130
d
17230'
Vickers Hardness
In the Vickers hardness test, a diamond pyramid indenter with a 136 angle between oppo-
site faces is pressed into the specimen under a test force F (kgf). The hardness number (HV) is
obtained by dividing F by the area, A (mm2), of contact between the indenter and specimen.
This area is calculated from the diagonal length, d (mm), of the indention when the indenter
is removed.
The Vickers hardness test is the most versatile hardness testing method of those that use
different load settings. The Micro-Vickers hardness test, which accepts load settings of 1
kgf (9.807N) or less, is especially well suited for industrial production today, where accuracy
requirements are increasing due to technology improvements.
Vickers hardness testing at loads of 1 kilogram and up is also known as heavy load Vickers or
Macro Vickers. The other testing parameters are similar to lighter load vickers testing. This type
of testing may be used to meet the requirements of international specications or to replace
Rockwell testing.
Knoop Hardness
In the Knoop hardness test, a diamond pyramid indenter, which has a rhombic base with
included angles of 17230 and 130, is pressed onto the specimen under a test force F (kgf).
The hardness number (HK) is obtained by dividing the test force F by the projected area, A
(mm2), of the indentation. This area is calculated from the longer diagonal length, d (mm), of
the indentation when the indenter is removed.
The Knoop hardness scale is generally used when shallower depth indentions are required.
Knoop hardness can be measured by installing a Knoop indenter on the Macro-Vickers hard-
ness testing machine.
Polished Surface
Scratched Surface
Ground Surface
K-4
Selecl swilch
lndenlalion
value display
Hardness value display
Scroll key
Hardness scale display
OK/NC display
Slarl swilch
Posilion inlormalion display
Correclion inlormalion
display
lndenlalion value display
OK/NC judgmenl display
Hardness value display
Tesl lorce dwell lime display
Prinl swilch
Tesl lorce display
Conversion value display
Slarl swilch
Zero-sel swilch
Menu swilch
Lighl adjuslmenl swilch
Tesl lorce dwell lime
selling swilch
Turrel swilch
(only lor models wilh
lhe power lurrel)
Measuremenl poinl
counl display
HM-101 / 112 / 113 / 122 / 123
SERIES 810 Micro-Vickers Hardness Testing Machines
FEATURES
A wide range of test force from 9.807
X10-3N to 9.807N (10gf to 1000gf)is
available for measuring a various type of
specimens. The load duration can be set in
1sec increments between 5 and 99sec*.
The minimum reading of indentation is
0.01m* and allows small indentations to
be measured with high precision. *HM-112, HM-
113
Up to 3 Objective lenses and 1 or
2 indenters mounted on manual or
motorized turret
Eyepiece or CCTV
Measuring Versions
Camera port
Optional Accessories
See Page K-10
Touch screen type
HM-123
HM-113
Reduce individual
differences in visual
measurement with the TV
monitor. The statistical
calculation function
reduces operation time.
HM-112
Digital display of
measurement results
and a statistical calculation
function.
SPECIFICATIONS
Model HM101 HM-112 HM-113 HM122 V HM122 V/K HM-123
Order No. 810-124A 810-126-07A 810-969-04A 810-127-04A 810-127-02A 810-990-02A
Supplied Indenter VICKERS VICKERS/KNOOP
Test force* 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g),
1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g)
Test force selection Dial
Loading control Automatic (loading, duration, unloading)
Load duration 5s30s 5s to 99s (specied in 1-second increments)
Loading Rate 60m/sec.
Objective Lenses 10x, 50x 10x, 50x 10x, 20x, 50x
Turret Manual Motor Drive
Measuring microscope
total magnication
100x, 500x 100x, 500x 100x, 200x, 500x
Video monitor screen
Total Magnication
9 B/W
250x, 1250x
9 B/W
250x, 500x, 1250x
Filar eyepiece 10x 10x 10x 10x
Minimum reading 0.2mm 0.01m
Maximum Reading 140m 700 / 140m 500 / 100m 700 / 350 / 140m 500 / 250 / 100m
Type Micrometer Drum Digital Optical Encoder
XY stage
Dimension
100 x 100mm 100 x 100mm
Travel range 25 x 25mm 25 x 25mm
Minimum reading 0.01mm 0.001mm
Specimen
Maximum height 95mm
150mm Maximum depth
Display Function Conversion;
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF
Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF
OK/NG Judgement
Curve correction: 0.01 to 200.00mm
Data processing;
Number to measurements 2 to 256 data
Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n)
Output RS-232C, SPC, Centronics
Dimensions Main unit: W=16.1 x D=23.6 x H=23.2 (410 x 600 x 590mm)
Display: W=6.5 x D=10.2 x H=4.1 (165 x 260 x 105mm)
Weight Main unit: 92.4 lbs. (42kg)
Power supply 120V AC (10%), 60 Hz
Power consumption 20VA 60VA
HM-101
K-5
Selecl swilch
lndenlalion
value display
Hardness value display
Scroll key
Hardness scale display
OK/NC display
Slarl swilch
Posilion inlormalion display
Correclion inlormalion
display
lndenlalion value display
OK/NC judgmenl display
Hardness value display
Tesl lorce dwell lime display
Prinl swilch
Tesl lorce display
Conversion value display
Slarl swilch
Zero-sel swilch
Menu swilch
Lighl adjuslmenl swilch
Tesl lorce dwell lime
selling swilch
Turrel swilch
(only lor models wilh
lhe power lurrel)
Measuremenl poinl
counl display
SPECIFICATIONS
Model HM114 HM115 HM-124 HM125
Order No. 810-128A 810-998A 810-129A 810-975A
Standard Indenter Vickers
Test force 9.807mN(1gf), 19.61mN(2gf), 29.42mN(3gf),
49.03mN(5gf), 98.07mN(10gf),
245.2mN(25gf), 490.3mN(50gf),
980.7mN(100gf), 1961mN(200gf),
2942mN(300gf), 4903mN(500gf),
9807mN(1000gf), 19610mN(2000gf)
4.903mN(0.5gf), 9.807mN(1gf), 19.61mN(2gf),
29.42mN(3gf), 49.03mN(5gf), 98.07mN(10gf),
245.2mN(25gf), 490.3mN(50gf),
980.7mN(100gf), 1961mN(200gf),
2942mN(300gf), 4903mN(500gf),
9807mN(1000gf), 19610mN(2000gf)
Test force selection Dial > 25gf, Electronic 25gf and below
Load control Automatic (loading, duration, unloading)
Load duration 5 to 99 sec (specied in 1-second increments)
Loading rate 60 mic/sec > 25gf, 1, 3, 5, 33 mic/sec 25gf and below
Objective lenses 10X, 50X, 100X
Turret Manual Motorized
Measuring microscope
Total magnication
100X, 500X, 1000X, 100X, 500X, 1000X,
Video monitor screen
Total magnication
250X, 1250X, 2500X 250X, 1250X, 2500X
Filar Eyepiece 10X 10X
Minimum reading 0.01m
Maximum Reading 700 / 140 / 70 m 450 / 90 / 45 m 700 / 140 / 70 m 450 / 90 / 45 m
Type Digital Encoder
XY stage
Dimensions
100 x 100mm
Travel range 25 x 25mm
Minimum reading 0.001mm
Specimen
Maximum height 3.74 (95mm) 3.54 (90mm)
Maximum depth 5.9 (150mm) 3.94 (100mm) from
center of in denter shaft
Display functions Conversion;
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF
Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF
OK/NG Judgement
Curve correction: 0.01 to 200.00mm
Data processing;
Number to measurements 2 to 256 data
Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n)
Output RS-232C, Centronics, SPC
Dimensions (WxDxH)
Main unit only
16.1 x 23.6 x 23.2 (410 x 600 x 590mm)
Weight 42kg
Power supply 120V AC (10%) 60Hz
Power consumption 20VA
3 lenses for best resolution of indent size
Manual or motorized turret
Eyepiece or CCTV
Measuring Versions
Camera port
HM-114 / 115 / 124 / 125
SERIES 810 Extended Range Micro-Vickers
Hardness Testing Machines
FEATURES
A wide range of test force from 4.903x10-
3N to 19.61N is available for measuring
a various type of specimens. The load
duration can be set in 1sec increments
between 5 and 99sec. The minimum
reading of indentation is 0.01m. Allowing
small indentations to be measured with
high precision.
Optional Accessories
See page K-10
Touch screen type
HM-114
K-6
HM-211 / 221
SERIES 810 Micro-Vickers Hardness Testing Machines
Consumable Parts
19BAA207: Illumination lamp (1 pc.)
SPECIFICATIONS
Model No. HM-211 HM-221
Order No. 810-352A 810-353A
Test force range 98.07mN to 980.7mN (9.807mN increments),
980.7mN to 9807mN (98.07mN increments)
(10gf to 100gf in 1gf increments)
(10gf to 1000gf in 10gf increments)
0.4903mN,
0.9807mN to 9.807mN (0.9807mN increments),
9.807mN to 980.7mN (9.807mN increments),
980.7mN to 19610mN (98.07mN increments)
(0.05, 0.1 - 1gf in 0.1gf increments)
(1 - 100gf in 1gf increments)
(100 - 2000gf in 10g increments)
Test force control Force generation by electromagnetic and automatic control (load, dwell, unload)
Control unit Touch screen type Touch screen type
Video monitor
Indenter/objective turret Motor driven and manual operation Motor driven and manual operation
No. of indenter mount 2 2
No. of objective mount 4 (10X and 50X are standard accessory) 4 (10X, 50X and 100X are standard accessory)
FEATURES
The latest electromagnetic force motor
used in the loading mechanism has
enabled the test force to be freely selected
(see test force specications over the wide
range of 0.4903mN (0.05gf) to 19810mN
(2kgf). It is also possible to freely set the
time for loading and load dwell time. Now
your desire for absolute control over the
indentation size in Vickers hardness testing
can be satised. The HM-200 series always
offers the test force most appropriate for
the specimen material and shape.
It is possible to perform not only the
Vickers hardness test but also a fracture
toughness test (IF test: JIS R 1607-1995)
on ceramics.
Technical Data
Test force range:
HM-211: 98.07mN to 980.7mN (9.807mN increments)
980.7mN to 9807mN (98.07mN increments)
HM-221: 0.4903mN
0.9807mN to 9.807mN (0.9807mN increments)
9.807mN to 980.7mN (9.807mN increments)
980.7mN to 19610mN (98.07mN increments)
Test force generation: Electromagnetic
Load control: Automatic (loading, duration, unloading)
Load duration: 1 - 999 sec (1 sec increment)
XY stage
Stage size: 100 x 100mm
Travel range: 25 x 25mm, with micrometer heads
Mim. reading: 0.001mm
Max. specimen height: 133mm
Max. specimen depth: 160mm (from the center of indenter)
Indenter/objective turret: Motor driven and manual operation
No. of indenter mount: 2-mount
No. of objective mount: 4-mount
Optical path: 2-way (measurement / camera exposure)
Minimum reading: 0.01m
Data output: RS-232C, Digimatic code (SPC) and
Centronics
Power supply: 100/120/220/240V AC, 50/60Hz
Dimensions (W x D x H): 400 x 625 x 600mm
Mass: 43kg
Power turret with 2 indenter mounts and 4
objective mounts
(manual operation possible)
Touch switch type control panel
Optional Accessories
* See page K-10 for more accessories
The objectives used enable a very
comfortable working distance between the
objective and the specimen surface. This
greatly reduces the possibility of collision
between the specimen and the objective
during focusing operations.
(e.g. 1.1mm for 50X objective)
The contrast that is most appropriate
for the magnication of the objective
can be obtained by manipulating the
variable aperture stop in the illumination
unit. This makes the indentations clearly
visible, leading less variation and reducing
the chance of error when measuring the
diagonal lengths.
K-7
AAV-500
SERIES 810 Automatic Vickers Hardness Testing System
AAV-501
An indentation dimension automatic
detecting time of 0.3 seconds is
achieved (when a PC with recommended
specications is used), which dramatically
improves operation efciency.
Detecting reproducibility of 0.5% is
achieved (For objective lens 50X, diagonal
line 11 to 45mm, and 500HV), which
provides reliable and stable test results.
All operations from test condition setting
to test result analysis can be performed
on a Windows PC. In addition, data
processing for the test results can be
performed by using spreadsheet software.
The AAV-500 Series reduces individual
differences in impression dimension
measurement in the Vickers hardness test by
adopting special image analysis technologies.
In addition, improved precision and high speed
have been realized with a detecting time of 0.3
seconds.
FEATURES
It can perform all operations required in the
Vickers hardness test and Knoop hardness
test such as loading, turret indexing,
SPECIFICATIONS
Model No. AAV-501 AAV-502 AAV-503 AAV-504
Order No.* 810-725A 810-726A 810-727A 810-728A
Test force range 98.07 - 9807mN
(10 - 1000gf)
4.904 - 19610mN
(0.5gf - 200gf)
1.961 - 196.1N
(200gf - 20kgf)
9.807 - 490.3N
(1kgf - 50kgf)
Test force switching By external PC By external PC Manual Manual
Objective 10X / 50X 10X / 50X / 100X 10X / 20X 10X / 20X
Measurable indentation size 20 - 200 / 4 - 40m 20 - 200 / 4 - 40 / 2 - 20m 40 - 400 / 20 - 100m 40 - 400 / 20 - 100m
Minimum reading 0.1m 0.1m 0.1m 0.1m
* PC is optional
Technical Data
Automatic indication detection
Detecting reproducibility: 0.5% (0.1m)
Detecting method: Quadratic curve regression
method
Detecting time: 0.3 seconds
Detecting minimum unit: 0.1m
Manual measurement function: Measurement method
with video line
X-Y automatic stage
Stage area: 130 x 130mm
Movement range: 50 x 50mm
Minimum pitch: 1m
Software function
Patterned measurement: Line, staggered, 3-point
staggered, matrix, circle, arc,
random
Teaching measurement pattern setting
Hardness calculation function
Hardness conversion function
OK/NG judgment
Analysis software function:
Device condition display
Measurement data display
Statistical calculation
Graph display
Dimensions (W x D x H) / Mass
AAV-501 / AAV-502: 450 x 545 x 950mm / 77kg
AAV-503 / AAV-504: 665 x 516 x 1000mm / 91kg
System Conguration
Power turret
X-Y automatic stage
Auto focus (AF) stage
Hardness testing
machine
PC-AT drive
PC
Measurement
microscope
TV monitor
Video printer
Joystick box
Printer
: Optional accessories
focusing, indentation dimension detecting,
and measurement position movement in full
automatic, so it is optimal for labor saving
requirements of your test environment.
Optional Accessory
PC System
K-8
MZT-500
SERIES 810 Micro Zone Test System
When it comes to evaluating mechanical
properties of ultra-small regions of ultra-
ne specimens, the MZT-500 Series are
most powerful in the elds of research
and development and quality control.
The MZT-500 can evaluate mechanical
properties, which the conventional hardness
Test data
You can obtain the indentation factor, which is related to
the hardness value (partially) shown in Martens hardness
test (ISO14577) and Youngs modulus. Deformation
characteristics in the load, dwell, and unload phases are
also obtainable for use in determining properties of the
specimen material.
Hardness tests such as Vickers and Knoop hardness tests
are supported. (MZT-512 and 522 only)
The balance lever vibration isolation mechanism reduces
the effect of external vibrations on measurements.
The impression position precision is 0.5mm or less.
Material characteristics evaluation of micro powder is
available.
Indenter indentation depth can be measured up to a
maximum of 20mm with a measurement resolution of
0.1nm.
Test force between 0.098mN and 980.7mN can be applied
electromagnetically for evaluation of material properties in
submicroscopic areas.
Field-compatible form with cover for protection against
dust and wind.
Test force loading device
Test force range 0.098 to 980.7mN
Control resolution 0.916N
Loading speed 0.1 to 100mN/s
Indenter indentation depth
measurement device
Measurement range 0 to 20m
Measurement minimum unit 0.1nm
Indenter Type Bercovici triangular pyramid indenter
Sample surface observation
device
Camera 1/3 inch black and white (410,000 pixels)
Monitor 9 inch black and white
Objective (monitor magnication) 100X (2600X), 10X (260X)
Specimen dimensions
Maximum dimension 90mm
Maximum depth 90mm (From the center of the indenter axis)
Test type
Indenter indentation test (with an preliminary test force)
Indenter indentation test (without an preliminary test force)
Indentation depth setting test, continuous indenter indentation test, repeated
indenter indentation test
SPECIFICATIONS
Model No. MZT-511 MZT-512 MZT-521 MZT-522
Order No. 810-809A 810-810A 810-811A 810-812A
Basic system 4 4 4 4
Data analysis / control
device
4 4 4 4
Video line
measurement software
4 4
Automatic multi-point
measurement device
4 4
testing machines for ne specimens cannot
measure, such as: various CVD and PVD-
deposited or generated lms, including ion-
plated lms; hardness of ultra-ne cross-
sections; bonding mechanical properties;
and wear mechanical properties of carbon
ber, glass ber, whisker, etc.
K-9
HV-112 / 113 / 114 / 115
SERIES 810 Vickers Hardness Testing Machines
FEATURES
A wide range of test forces from 1.961N
to 490.3N* (.2kgf - 50kgf) is available for
measuring a wide variety of specimens.
The load duration can be set in 1sec
increments between 5 and 99sec.
The minimum reading of indentation is
0.1m. It allows small indentations to be
measured with high precision.
Function: Control unit
Back-lit LCD graphic display for
Indentation size (D1 and D2),
Hardness value and scale,
Number of measurement point
Test conditions (HV / HK indenter
type, test force, load duration),
GO / NG tolerance judgment,
Cylindrical and spherical surface
compensation and offset
Remote control of power turret
Conversion to other hardness
scales
Statistical processing
Optional Accessories
See page K-10
Consumable Parts
810-087: Illumination lamp (1 pc.)
HV-112, HV-114
HV-113, HV-115
SPECIFICATIONS
Model HV112 HV113 HV114 HV115
Order No. 810-163A 810-981A 810-165A 810-985A
Test force 1.961N (0.2kgf), 2.942N (0.3kgf),
4.903N (0.5kgf), 9.807N (1kgf),
24.51N (2.5kgf),
49.03N (5kgf), 98.07N (10kgf), 196.1N (20kgf)
9.807N (1kgf), 19.61N (2kgf),
29.42N (3kgf),49.03N (5kgf),
98.07N (10kgf), 196.1N (20kgf),
294.2N (30kgf), 490.3N (50kgf)
Test force selection Dial
Loading accuracy 1%
Load control 50 - 100/s Automatic (loading, duration, unloading) Automatic
Load rate 5~99 sec.
Objective lenses 10X, 20X
Measuring microscope
Total magnication
100X / 200X 100X / 200X
Measuring range 350, 700m 350, 700mm
Minimum reading 0.1m
Video monitor
Camera
CCD CCD
Display 9 monochrome CRT 9 monochrome CRT
Total magnication 250X, 500X 250X, 500x
Monitoring range 520 x 670m,
260 x 330m
520 x 670m, 260 x 330m
Measuring range 410 x 570m,
200 x 280m
410 x 570m, 200 x 280m
Display Function Conversion:
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV,
Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB,HRG, HK, HV,
Statistical list; N, Max., Min., Average, Range, High, Low, Good, Over,
Under, SD(n-1), SD(n-1), SD(n) OK/NG Judgement, Curve correction; 0.01 to 200.00mm
Specimen
Maximum height
8.07 (205mm) or Flat anvil
Maximum depth 6.7 (170mm) from center of indenter shaft
Optical path 2-way switchable (microscope/photograph)
Output SPC, RS-232C Centronics
Power supply 120V AC (10%) 60Hz
Dimensions (WxDxH)
Main Unit only
9.7 x 20.3 x 31.3 (245 x 515 x 770mm)
Mass 110 lbs. (50kg) 121.4 lbs. (55.2kg) 110 lbs. (50kg) 121.4 lbs. (55.2kg)
* 7.48 (190mm) if using 50 x 50mm-travel XY stage (No. 810-012).
Technical Data
Motorized lens turret
Adjustable loading rate
K-10
Optional Accessories
Micro-Vickers/Vickers Hardness Testing Machine
Indenters
Order No. Type Model
19BAA061 Knoop Indenter H, HM Standard Series
19BAA058 Vickers Indenter H, HM Standard Series
19BAA062 Knoop Indenter MVK-H2, H3, HM114
19BAA059 Vickers Indenter MVK-H2, H3, HM114
19BAA060 Vickers Indenter HV, AVK-C Series
Test Blocks
Order No. Description Load
64BAA173 Vickers 100HV Test Block 100gf
64BAA174 Vickers 200HV Test Block 100gf
64BAA175 Vickers 300HV Test Block 100gf
64BAA176 Vickers 400HV Test Block 100gf
64BAA177 Vickers 500HV Test Block 100gf
64BAA178 Vickers 600HV Test Block 100gf
64BAA179 Vickers 700HV Test Block 100gf
64BAA180 Vickers 800HV Test Block 100gf
64BAA181 Vickers 900HV Test Block 100gf
64BAA182 Vickers 100HV Test Block 500gf
64BAA183 Vickers 200HV Test Block 500gf
64BAA184 Vickers 300HV Test Block 500gf
64BAA185 Vickers 400HV Test Block 500gf
64BAA186 Vickers 500HV Test Block 500gf
64BAA187 Vickers 600HV Test Block 500gf
64BAA188 Vickers 700HV Test Block 500gf
64BAA189 Vickers 800HV Test Block 500gf
64BAA190 Vickers 900HV Test Block 500gf
64BAA191 Vickers 100HV Test Block 1000gf
64BAA192 Vickers 200HV Test Block 1000gf
64BAA193 Vickers 300HV Test Block 1000gf
64BAA194 Vickers 400HV Test Block 1000gf
64BAA195 Vickers 500HV Test Block 1000gf
64BAA196 Vickers 600HV Test Block 1000gf
64BAA197 Vickers 700HV Test Block 1000gf
64BAA198 Vickers 800HV Test Block 1000gf
64BAA199 Vickers 900HV Test Block 1000gf
64BAA200 Knoop 200HK Test Block 100gf
64BAA201 Knoop 300HK Test Block 100gf
64BAA202 Knoop 400HK Test Block 100gf
64BAA203 Knoop 500HK Test Block 100gf
64BAA204 Knoop 600HK Test Block 100gf
64BAA205 Knoop 700HK Test Block 100gf
64BAA206 Knoop 800HK Test Block 100gf
64BAA207 Knoop 250HK Test Block 500gf
64BAA208 Knoop 300HK Test Block 500gf
64BAA209 Knoop 400HK Test Block 500gf
64BAA210 Knoop 500HK Test Block 500gf
64BAA211 Knoop 600HK Test Block 500gf
64BAA212 Knoop 700HK Test Block 500gf
64BAA213 Knoop 800HK Test Block 500gf
64BAA214 Knoop 250HK Test Block 1000gf
64BAA215 Knoop 300HK Test Block 1000gf
64BAA216 Knoop 400HK Test Block 1000gf
64BAA217 Knoop 500HK Test Block 1000gf
64BAA218 Knoop 600HK Test Block 1000gf
64BAA219 Knoop 700HK Test Block 1000gf
64BAA220 Knoop 800HK Test Block 1000gf
*other ranges available
Bulbs
Order No. Description
513667 Bulb, 12v/50w, halogen double pin type, HM series with box style illuminators.
19BAA219 Bulb, 6v/2 0w, halogen double pin type, Later H series
19BAA095 Bulb, 6v/15w, halogen bayonet type, all E, G and early H series testers.
Used to secure a specimen, that has a
measuring surface that is hard to stabilize,
perpendicular to the indenter axis.
810-020
Dimensions: 4.92x4.92(125x125mm)
Minimum reading: 0.01mm
810-012
Universal Specimen Holder
50x50mm travel stage
Clamping devices (Vises)
Vise
Max. opening: 1.77(45mm)
Standard for the MH series.
810-016
Clamping devices (Vises)
Vise
Max. opening: 3.94(100mm)
810-017
Rotary Table
Vise
Max. opening: 3.94(100mm)
810-017
Specimen (thin plate) Holder
Secures a plate with a thickness of
.197(5mm) or less, or foil-like specimens.
810-013
Specimen (wire) Holder
Used to horizontally secure a wire or needle specimen
that has a diameter of .126(3.2mm) or less.
810-014
Specimen (wire or ball) Holder
Used to vertically secure a wire or ball specimen that
has a diameter of .126(3.2mm) or less.
810-015
Round Tables
Dimensions: 8(203mm)
810-037-7
K-11
Hardness and Hardness Measurement
Hardness is a measure of resistance of a material to deformation when an external force or load is
applied to the material. There are several hardness scales, which use different methods of applying
force and quantifying the resistance to deformation. Hardness is closely correlated to other mechanical
characteristics. It is, like many other mechanical characteristics, a relative value that has no fundamen-
tal quantity or absolute standard and is different from physical quantities such as length, time, and
force. Because of this, hardness values are determined using a standard testing machine under stan-
dard conditions.
Today the most popular hardness scales are Brinell hardness (HB), Vickers hardness (HV), Rockwell and
Rockwell supercial hardness (HR) and Knoop hardness (HK). Most hardness tests determine hardness
from the area of the indentation made in a specimen by the indenter under a known load. The Brinell
test was devised in Sweden, the Vickers test in the United Kingdom, and the other hardness tests
in the United States. Although hardness is a relative value, Brinell, Vickers, and Knoop hardness are
expressed in a unit of stress (1 kgf/mm2 or 9.8MPa).
Rockwell Hardness and Rockwell Supercial Hardness
In the Rockwell hardness and the Rockwell supercial hardness tests, a conical diamond indenter with
a 120 angle and a radius of curvature of 0.2mm, or a steel or carbide ball indenter is pressed into the
specimen. First, a preliminary test force is applied, then a total test force is applied, and then the test
load is reduced to the preliminary test force. The hardness number is determined from the difference, h,
of the indentation depth of the indenter between the rst and second applications of the preliminary
test force.
The Rockwell hardness test uses a preliminary load of 10kgf, and the Rockwell supercial hardness test
uses a preliminary test force of 3kgf. The Rockwell and Rockwell supercial hardness have multiple
scales to indicate specic combinations of the indenter type, test force, and formula to obtain the
hardness. A unique symbol is given to each scale.
Scale Indenter Test force Applications
A Diamond 588.4N(60kgf) Cemented carbide, thin steel plates
case hardened steel D 980.7N(150kgf)
C 1471N(150kgf)
F 1/16
diameter
steel ball
588.4N(60kgf) Bearing metal, copper, annealed steel,
brass, hard-drawn aluminum alloys
beryllium copper, phosphor bronze
B 980.7N(100kgf)
G 1471N(150kgf)
H 1/8
diameter
steel ball
588.4N(60kgf) Bearing metal
E 980.7N(100kgf)
K 1471N(150kgf)
L 1/4
diameter
steel ball
588.4N(60kgf) Plastics, lead
M 980.7N(100kgf)
P 1471N(150kgf)
R 1/2
diameter
steel ball
588.4N(60kgf) Plastics
S 980.7N(100kgf)
V 1471N(150kgf)
Scale Indenter Test force Applications
15N Diamond 147.1N(15kgf) Carburized layer, sintered
30N 294.2N(30kgf)
45N 441.3N(45kgf)
15T 1/16
diameter
steel ball
147.1N(15kgf) Thin copper plates (brass, bronze),
mild steel 30T 294.2N(30kgf)
45T 441.3N(45kgf)
15W 1/8
diameter
steel ball
147.1N(15kgf) Plastics, zinc, bearing alloys
30W 294.2N(30kgf)
45W 441.3N(45kgf)
15X 1/4
diameter
steel ball
147.1N(15kgf) Plastics, zinc, bearing alloys
30X 294.2N(30kgf)
45X 441.3N(45kgf)
15Y 1/2
diameter
steel ball
147.1N(15kgf) Plastics, zinc, bearing alloys
30Y 294.2N(30kgf)
45Y 441.3N(45kgf)
Rockwell hardness scales
Preliminary test force: 98.07N (10kgf)
Rockwell Supercial hardness scales
Preliminary test force: 29.42N (3kgf)
K-12
HR-521 / 523
SERIES 810 Rockwell Type Hardness Testing Machines
FEATURES
Multiple test force generation for
Rockwell, Rockwell Supercial and Brinell
hardness.
Dolphin-nose indenter arm for easy reach
of interior (min. 40mm/22mm*) and
exterior surfaces.
*When using an optional diamond indenter (19BAA292).
Real time electronic test force control for
accurate loading. This perfectly eliminates
load force overshooting.
Function: Touch screen type
Touch screen operation with a back-lit LCD graphic display.
Remote selection of the test force linked to the hardness
scale selection.
Choice of message language in English, German, French,
Spanish, Italian and Japanese for user friendly operation.
Cylindrical and spherical surface compensation.
Data offset
Conversion to other hardness scales.
Powerful statistical processing with exible data point
editing and 1024 data memory.
Measured data editing
OK/NG tolerance judgment.
Statistical processing, histogram and x-R chart
Technical Data
Preliminary test force: 29.42N, 98.07N
Test force
Rockwell supercial: 147.1, 294.2, 441.3N
Rockwell: 588.4, 980.7, 1471N
Brinell*: 61.29, 98.07, 153.2, 245.2, 294.2,
306.4, 612.9, 980.7, 1226, 1839N
Test force setting: By control unit
Load control: Automatic
(loading, duration, unloading)
Load duration: 0s - 120s (1s increments)
Max. specimen height: 205mm (for standard at anvil)
Max. specimen depth: 150mm
(from the center of indenter shaft)
Stage elevation: Manual or power drive
Control unit: Sheetswitch type or touch screen type
Data output: RS-232C, Digimatic code (SPC) and
Centronics
Power supply: 120V AC, 50/60Hz
Dimensions (W x D x H)
Main unit: 250 x 670 x 605mm
Control unit: 165 x 260 x 105mm
HR-523
810-204-02A
HR-521
810-202-02A
Optional Accessories: See page K-14, 15.
Various shapes of specimen can be measured.
(Nose-type indenter axis mechanism has been adopted)
The nose-type indenter mechanism allows measurement of
pipe samples as well as the top surface of a at sample.
Indenter escape function for continuous
testing at xed table position. This
eliminates instability caused by the table
retraction.
Auto-stop elevation table and automatic
preliminary test force loading to provide
stable test force generation.
SPECIFICATIONS
Model HR-521 HR-523
Order No. 810-202-02A 810-204-02A
Preliminary Test Force 29.42N (3kgf), 98.07N (10kgf)
Test Force Rockwell 588.4N (60kgf), 980.7N (100kgf), 1471N (150kgf)
Rockwell Supercial 147.1N (15kgf), 294.2N (30kgf), 441.3N (45kgf)
Force Control Automatic control (unloading/duration/unloading) with closed loop feed back
Console/Display Unit Touch screen operation with back-lit LCD graphic display
Test Force Selection By touch screen
Table up/down drive Manual (w/Auto-brake mechanism) Power-Drive (for full-automatic measurement)
Load Duration 0 to 120 sec. (1 sec. step)
Maximum Specimen Height Height: 205mm Depth: 150mm from center of indenter shaft
Display Indication Functions Hardness value, Converted hardness value, Test conditions, OK/NG tolerance judgement,
statistical processing result
Rockwell/Rockwell supercial hardness testing. Continuous testing.
Cylindrical/spherical surface compensation, data offset
Hardness conversion (HV, HK, HRA/B/C/D/F/G/15T/30T/45T/15N/30N/45N, HS, HB,
HBW, tensile strength)
OK/NG tolerance judgement, measured data editing, data memory (max 1024 data)
SPC calculation (No. of data, max/min/mean values, range, upper/lower limit values,
standard deviation, No. of passing/defective) Histogram, x-R chart
Data Output RS-232C, SPC, Centronics
Dimensions (W x D x H) 9.84 x 26.38 x 23.82 (250 x 670 x 605mm)
Mass 60kg
K-13
Optional Accessories
See page K-14 & K-15
AR-20, ARK-600 / 601, ATK-600 / 601
SERIES 810 Rockwell/Rockwell Supercial Hardness Testing Machine
FEATURES:
Economy type Rockwell hardness testing
machines.
Diamond indenter (HRA, HRD, HRC) and
1/16" diameter steel ball indenter (HRF,
HRB, HRG) are provided.
ATK-600 AR-20
Technical Data
Preliminary test force: 29.42N*, 98.07N
Test force
Rockwell supercial*: 147.1, 294.2, 441.3N
Rockwell: 588.4, 980.7, 1471N
Test force setting: By dial
Load control: Automatic
(loading, duration, unloading)
Anvil: Flat (64mm)
Max. specimen height: 140mm
Max. specimen depth: 122mm
(from the center of indenter shaft)
Stage elevation: Manual
Data output**: RS-232C, Digimatic code (SPC)
Power supply: 120V AC, 50/60Hz
*ATK-600 only
**ARK-600 and ATK-600 only
The dial indicator can be zero-set
automatically, allowing the preliminary test
load to be applied with the table elevation
wheel only.
Test load selection can be made with
wheel. (AR-20)
SPECIFICATIONS
Model AR-20 ARK-600 ARK-601 ATK-600 ATK-601
Order No. 810-201A 810-218A 810-220A 810-257A 810-258A
Preliminary test
force
98.07N (10kgf) 98.07N (10kgf), 29.42 (3kgf)
Test force 588.4N (60kgf), 980.7N (100kgf), 1471N (150kgf) 147.1N(15kgf), 294.2N(30kgf),
588.4N(45kgf), 588.4N (60kgf), 980.7N
(100kgf), 1471N (150kgf)
Table up/down
drive
Manual (with Loading Navigator)
Load control Automatic (loading, duration, unloading)
Load duration Automatic (3s to 5.5s) or manual
Display Dial LED (4-digit)
Hardness
increment
0.5 0.1 (for each scale) 0.1 (for Rockwell each scale),
0.2 Rockwell Supercial (for each scale)
Specimen
Maximum height
5.51 (140mm)
on Flat Anvil
5.91 (150mm)*
on Round Table
12.60 (320mm)
on Flat Anvil
13.00 (330mm)*
on Round Table
5.51 (140mm)
on Flat Anvil
5.91 (150mm)*
on Round Table
11.02 (280mm)
on Flat Anvil
11.42 (290mm)*
on Round Table
Maximum depth 4.8 (122mm) from center of indenter shaft
Output RS-232C, SPC
Power supply 120V AC (10%), 60Hz
Power
consumption
30VA
Dimensions (W x
D x H)
8.27 x 19.13 x 26.77
(210 x 486 x 680mm)
8.27 x 19.13 x
33.86
(210 x 486 x
860mm)
8.27 x 19.13 x
28.35
(210 x 486 x
720mm)
8.27 x 19.13 x 33.86
(210 x 486 x 860mm)
Mass 88 lbs. (40kg) 99 lbs. (45kg) 93 lbs. (42kg) 99 lbs. (47kg)
* Minimum height: .39 (10mm)
K-14
Order No. Hardness
64BAA159 HRA81/86 Rockwell Test Block
64BAA160 HRA75/79 Rockwell Test Block
64BAA161 HRA70/73 Rockwell Test Block
64BAA162 HRA65/68 Rockwell Test Block
64BAA163 HRA60/62 Rockwell Test Block
64BAA249 HRBW95/100 Rockwell Test Block
64BAA126 HRBW90/95 Rockwell Test Block
64BAA131 HRBW80/85 Rockwell Test Block
64BAA132 HRBW70/75 Rockwell Test Block
64BAA133 HRBW60/65 Rockwell Test Block
64BAA134 HRBW50/55 Rockwell Test Block
64BAA135 HRBW40/45 Rockwell Test Block
64BAA127 HRBW30/35 Rockwell Test Block
64BAA136 HRBW20/25 Rockwell Test Block
64BAA137 HRBW10/15 Rockwell Test Block
64BAA138 HRBW0/5 Rockwell Test Block
64BAA125 HRC60/65 Rockwell Test Block
64BAA157 HRC50/55 Rockwell Test Block
64BAA124 HRC40/45 Rockwell Test Block
64BAA123 HRC30/35 Rockwell Test Block
64BAA158 HRC20/25 Rockwell Test Block
Order No. Hardness
64BAA222 HR45N65/70 Rockwell Test Block
64BAA223 HR45N55/60 Rockwell Test Block
64BAA224 HR45N45/50 Rockwell Test Block
64BAA225 HR45N35/40 Rockwell Test Block
64BAA226 HR45N25/30 Rockwell Test Block
64BAA128 HR30N77/82 Rockwell Test Block
64BAA164 HR30N68/73 Rockwell Test Block
64BAA165 HR30N59/64 Rockwell Test Block
64BAA166 HR30N50/55 Rockwell Test Block
64BAA167 HR30N40/45 Rockwell Test Block
64BAA168 HR15N90/93 Rockwell Test Block
64BAA169 HR15N85/88 Rockwell Test Block
64BAA170 HR15N80/83 Rockwell Test Block
64BAA171 HR15N75/77 Rockwell Test Block
64BAA172 HR15N69/72 Rockwell Test Block
Order No. Hardness
64BAA129 HR30T74/79 Rockwell Test Block
64BAA139 HR30T70/73 Rockwell Test Block
64BAA140 HR30T63/67 Rockwell Test Block
64BAA141 HR30T56/60 Rockwell Test Block
64BAA142 HR30T49/53 Rockwell Test Block
64BAA130 HR30T43/47 Rockwell Test Block
64BAA143 HR30T36/39 Rockwell Test Block
64BAA144 HR30T29/33 Rockwell Test Block
64BAA145 HR30T22/26 Rockwell Test Block
64BAA146 HR30T15/18 Rockwell Test Block
64BAA147 HR15T90/92 Rockwell Test Block
64BAA148 HR15T86/69 Rockwell Test Block
64BAA149 HR15T83/85 Rockwell Test Block
64BAA150 HR15T80/82 Rockwell Test Block
64BAA151 HR15T77/79 Rockwell Test Block
64BAA152 HR15T72/74 Rockwell Test Block
64BAA153 HR15T70/72 Rockwell Test Block
64BAA154 HR15T68/69 Rockwell Test Block
64BAA155 HR15T64/66 Rockwell Test Block
64BAA156 HR15T61/63 Rockwell Test Block
Steel Ball Indenters
Order No. Description
64BAA074 1/16 diameter steel ball indenter
19BAA078 1/16 diameter steel ball indenter
(auto-discrimination type)
64BAA075 1/8 diameter steel ball indenter
19BAA079 1/8 diameter steel ball indenter
(auto-discrimination type)
64BAA076 1/4 diameter steel ball indenter
19BAA080 1/4 diameter steel ball indenter
(auto-discrimination type)
64BAA077 1/2 diameter steel ball indenter
19BAA081 1/2 diameter steel ball indenter
(auto-discrimination type)
64BAA082 1/16 diameter spare steel ball (10 pcs)
64BAA083 1/8 diameter spare steel ball (10 pcs)
64BAA084 1/4 diameter spare steel ball (10 pcs)
64BAA085 1/2 diameter spare steel ball (10 pcs)
Calibration Set
Order No. Order No.
64BAA241 64BAA242
C Scale Set B Scale Set
Test Blocks Test Blocks
64BAA125 64BAA126
64BAA124 64BAA132
64BAA158 64BAA135
Indenter Indenter
64BAA072 64BAA078
Order No. Order No.
64BAA243 64BAA244
30N Scale Set 30T Scale Set
Test Blocks Test Blocks
64BAA128 64BAA129
64BAA165 64BAA140
64BAA167 64BAA130
Indenter Indenter
64BAA073 64BAA078
Order No. Scale
64BAA072 C
64BAA073 N
64BAA086 A
64BAA071 C & N
3/8"
15/32"
7/16"
1/4"
Optional Accessories
For Rockwell/Rockwell Supercial Type Hardness Testing machine
Rockwell Type Diamond Indenters
Carbide Ball Indenters
Order No. Description
19BAA515 1/16 Carbide ball indenter
19BAA504 1/8 Carbide ball indenter
19BAA505 1/4 Carbide ball indenter
19BAA506 1/2 Carbide ball indenter
19BAA507 1/16 Carbide ball (1pc.)
19BAA508 1/8 Carbide ball (1pc.)
19BAA509 1/4 Carbide ball (1pc.)
19BAA510 1/2 Carbide ball (1pc.)
K-15
Diameter: 38(9.7mm)
Groove width: .38(9.7mm)
810-042-7
Diameter: 2.5(64mm)
810-039-7
Diameter: 1.5(38mm)
810-039-8
Flat anvil
Diameter: 8(203mm)
810-037-7
Round Table
Spot anvils
Diameter: .25(6.4mm)
Height: .88(22mm)
810-044-7
Diamond-tipped type for
Rockwell supercial hardness measurement
810-030-7
V-anvils
Diameter: 1.5(38mm)
Groove width: 1.5(38mm)
810-040-7
Diameter: 1.5(38mm)
Groove width: .38(9.7mm)
810-041-7
Adjustable height:
13 to18.5 (330 to 470mm)
Used to mount a V-anvil.
810-028-7
Adjustable support
264-504-5A
937386
Optional Accessories
For Rockwell/Rockwell Supercial Type Hardness Testing machine
K-16
Hardmatic HH-300
SERIES 811 Durometers for Rubber and Plastics Hardness Testing
FEATURES
Digital / Dial Durometers are suitable for
testing the nature of the following materials
natural rubber, neoprene, polyesters,
P.V.C., leather, Thiokol, nitrite rubber, wax,
vinyl, cellulose acetates, glass polystyrene, etc.
811-336
811-338
811-335-01
811-337-01
811-335
811-337
811-336-01
811-338-01
811-332
811-334
811-331
811-333
SPECIFICATIONS
Order No. Digital 811-330 811-336 811-336-01 811-332 881-338 811-338-01 811-334
Dial 811-329 811-335 811-335-01 811-331 881-337 811-337-01 811-333
Model No. Digital HH-330 HH-336 HH-336-01 HH-332 HH-338 HH-338-01 HH-334
Dial HH-329 HH-335 HH-335-01 HH-331 HH-337 HH-337-01 HH-333
Scale Shore E Shore A Shore D
Applications Soft Rubber,
Sponge,
Felt, Hard Foam,
Winder
Natural rubber,
soft elastomers, etc.
Hard elastomers, plastics,
hard rubber, ebonite, etc.
Resolution 0.5 (digital) or 1 (dial) 0.5 (digital) or 1 (dial)
Range HA: 10 - 90 HD: 20 - 90
Standards ASTM D
2240
3 3 3 3
ISO 868 3 3 3 3
ISO 7619 3 3 3 3
DIN 53 505 3 3
JIS K 6253 3 3 3 3 3
JIS K 7215 3 3 3 3
Pressure foot 44 x 18mm 44 x 18mm 18mm 44 x 18mm 18mm
Spring force (mN) WE=550+HE WA=550+75HD (HA:Reading 10-90) WD=444.5HD (HD:Reading 20-90)
Indenter Sphere
(Tip diameter:
0.79mm)
Blunt taper (Tip diameter: 0.79mm) Sharp point (Tip curvature: 0.1
0.01mm)
Tip angle 350.25 300.5
Indenter diameter 1.25mm
Indenter protrusion 2.5mm
Functions Digital: Data hold, Zero -setting, SPC output, Power ON/OFF (Power supply: SR44 x 1pc.) Analog
Durometer: Peak retaining hand
Type Compact Compact Long-leg Compact Long-leg
Dimensions
(WxDxH)
Digital 60 x 28.5 x 151 60 x 28.5 x 151mm 60 x 28.5
x 193mm
60 x 28.5 x 151mm 60 x 28.5
x 193mm
Dial 56 x 33.5 x 144mm 56 x 33.5 x 144mm 56 x 33.5
x 186mm
56 x 33.5 x 144mm 56 x 33.5
x 186mm
Mass Digital 290g 290g 310g 290g 310g
Dial 300g 300g 320g 300g 320g
Testing stand applications
These stands are used to mount Durometers. They allow
constant-pressure hardness measurement by pressing the
Durometer vertically on a workpiece.
Anyone can perform repeatable hardness measurement
due to fewer possibilities of human error and measurement
variations.
The supplied weights can be attached directly to a Durom-
eter and allow constant-pressure hardness measurement of
large samples for which a stand cannot be used.
The supplied weights are used for calibrating the spring
tension of Durometers.
Technical Data
Designed in accordance with the ASTM D 2240, ISO868,
ISO 7619, DIN 53 505, JIS K 6253, and JIS K 7215
specications.
Units are available in both Shore A and Shore D scales, and
will test a wide variety of applications.
The Digital Durometer is provided with data hold function,
permitting the operator to make an error-free reading on
the LCD screen.
The Dial Durometer is provided with a peak retaining hand
for error-free reading.
K-17
Hardmatic HH-300
Test Block Set
Item No. Description
19BAA180 Holding Bar
64AAA964 Calibration Set (Shore A Scale)
Test Block 30* DURO (Blue)
Test Block 60* DURO (Yellow)
Test Block 90* DURO (Gray)
Mahogany Box
64AAA590 Calibration Set (Shore D Scale)
Test Block 20* DURO (Blue)
Test Block 40* DURO (Gray)
Test Block 80* DURO (Black)
64AAA962 A Scale Durometer Stand
64AAA794 A Scale Durometer Stand with Air Damper
64AAA796 Combination D & A Scale Durometer Stand
64AAA963 O-Ring Fixture Set 1/16, 3/32, 1/8, 3/16 and 1/4
O-Ring cross sections
19BAA406 Digimatic Miniprocessor with printer
905693 Connecting Cable 40 (1m) for
Durometer and Digimatic Miniprocessor
Holding Bar
The holding bar is used to mount a Durometer on a
drill press.
19BAA406
811-332
905693
64AAA964
64AAA963
* Values shown are nominal only. Test Block Size 2 x 2 x 1/4
K-18
SPECIFICATIONS
Model HH-411
Order No. 810-298
Hardness Range L-Value (ASTM A956)
Detector Input device D (carbide ball)
Display Hardness Range Resolution
HL 1-999 HL 1 HL
HV 43-950 HV 1 HV
HB 20-894 HB 1 HB
HRC 19.3-68.2 HRC 0.1 HRC
HRB 13.5 - 101.7 HRB 0.1 HRB
HS 13.2 - 99.3 HS 0.1 HS
HTN 499 - 1996 Mpa 1 Mpa
Functions Conversions: HL,HV, HB, HRC, HRB, HS, HTN
Judgment: OK/NG
Offsetting
Memory: 1,800 data
Indentation Direction Any direction
Output RS-232C, SPC
Power supply Alkaline AA Battery 2pcs.
Dimensions Detector: (Dia. X H) 1.10 x 6.89
(28 x 175mm)
Display: (W x D x H) 2.76 x 4.33 x 1.38
(70 x 110 x 35mm)
Mass Detector: .26lbs (120g)
Display: .44lbs (200g)
Hardmatic HH-411
SERIES 810 Impact Type Hardness Testing Unit
Technical Data
Impactor: Impact hammer with integrated
detector and carbide-ball tip
(D type: conforming to ASTM A 956)
Display unit: 7-segment LCD
Functions: Auto angle compensation, Offset,
OK/NG judgment, Hardness scale
conversion
Data storage (1800 data entries)
Statistical analysis (Average,
Maximum, Minimum, Dispersion)
Auto sleep function
Impact counter display function
Testable workpiece
Thickness: Minimum 5mm or more
Mass: 5kg or more in mass
Test points: 5mm or more from the edge of the
sample, 3mm or more to each of the
tested points.
Surface roughness: Ra 10m or less
Power supply: Alkaline AA battery 2pcs or optional
AC adapter (battery life: 70 hours)
Standard Accessories
19BAA265 Test Block HLD800
19BAA450 Display
810-287 Detector
19BAA460 Cable
Battery AA (Alkaline) 2pcs.
Optional Accessories
264-504: Digimatic Mini-Processor DP-1VR
937387: Connecting cable for
09EAA082: Printer paper (10 rolls/set)
810-622: Thermal printer DUP-414
19BAA262: Thermal printer connecting cable
19BAA157: Thermal printer paper
19BAA238: RS-232C connecting cable for PC
526688A: AC adapter of display unit
19BAA243: Hardness test block (880HLD)
19BAA244: Hardness test block (830HLD)
19BAA245: Hardness test block (730HLD)
19BAA246: Hardness test block (620HLD)
19BAA247: Hardness test block (520HLD)
19BAA248: Support ring for convex surface of cylinder
(R10 - R20)
19BAA249: Support ring for convex surface of cylinder
(R14 - R20)
19BAA250: Support ring for convex surface of sphere
(R10 - R27.5)
19BAA251: Support ring for concave surface of sphere
(R13.5 - R20)
19BAA457: Carbide ball for D, DC, D+15 type impactors
19BAA458: Ball shaft for DL type impactor
810-287: D type impactor UD-411
810-288: DC type impactor UD-412
810-289: D+15 type impactor UD-413
810-290: DL type impactor UD-414
Impactors (Optional accessories)
Various impactors can be connected to the
display unit.
810-288
Use for inner walls of cylinders.
The grip is short to allow easy
positioning within a cylinder.
810-290
Use for gear teeth, welded corners, etc.
810-289
Use for concave workpieces
such as gear teeth, ball
bearing races, etc.
810-298: ASTM standard
Including the display unit, D type impactor
(810-287) and carbide ball (19BAA457).
HH-411 is a rebound type portable hardness
tester for metal with a compact body and
high operability. It allows anyone to perform
hardness testing easily at the touch of a
key, so it can be used widely on various
components in the eld.
Impactor
built-in carbide
ball
Display unit
K-19
FEATURES
This is a sensitive servo-type acceleration
pickup supporting acceleration measurement
of three rectangular components.
This vibration pickup can sensitively measure
SPECIFICATIONS
Order No. 825-242
Model No. V407-3-AT
Measuring range 30m/s
2
Output sensitivity (DC) Within 0.1V/(m/s
2
)6%
Output resistance 0.2k
Detecting axes Three
Phase characteristic 150Hz or more (deviation of 90
phase)
Frequency
characteristic
The output sensitivity is within
10% when DC is less than 150 Hz.
Resolution 4 x 10
-4
m/s
2
or less (DC: less than
1Hz)
1 x 10
-4
m/s
2
or less (DC: 1 to 30Hz)
5 x 10
-4
m/s
2
or less (DC: 30 to
150Hz)
Dimensions (W x D x H) 46 x 32 x 71mm
Mass 100 g (not including cable)
FEATURES
This is a sensitive acceleration pickup that
has realized a resolution of 1 x 10
-6
m/s
2
or less. This is the highest-level resolution
among servo-type acceleration pickups.
SPECIFICATIONS
Order No. 825-253 825-254
Model No. V405-BT V407-3-AT
Feedback Displacement feedback
Measuring range 30m/s
2
20m/s
2
Output sensitivity 3V/9.8m/s
2
5V/9.8m/s
2
Output resistance 2.8k 4.7k
Phase characteristic 500Hz or more (deviation of 90
phase)
Frequency range DC - 450Hz
Resolution 1 x 10
-6
m/s
2
or less
Linearity 0.05%
Horizontal sensitivity 0.1% or less
Test coil Yes
Power 13.5 to 26.5V, 15mA (DC)
Dimensions 32x33mm
Mass 90g (not including 1 m cable)
vibration of three rectangular components
in the low frequency area and is best
suited to ground and building vibration
measurements.
This machine is best suited to vibration
measurement of earthquakes, buildings
and ground, as well as active vibration
control to eliminate such vibration.
MicroAccel V407-3-AT
SERIES 825 Servo Type Acceleration Pickup
V405
SERIES 825 Servo Type Acceleration Pickup
K-20
FEATURES
The piezoelectric-type acceleration pickup
is a most common vibration pickup
and used for most machine vibrations.
Specically, they are generally amplied
to the signal level easy to process in
SPECIFICATIONS
Order No. 825-170 825-171 825-172 825-173
Model No. V311TE V311TB V311SB V311TF
Structure Shear-type Shear-type Shear-type Shear-type
Measuring range 20000m/s
2
5000m/s
2
5000m/s
2
3000m/s
2
Charge sensitivity 15PC / 9.8m/s
2
50PC / 9.8m/s
2
50PC / 9.8m/s
2
100PC / 9.8m/s
2
Natural frequency 40kHz 25kHz 25kHz 15kHz
Frequency range 3 - 10000Hz 3 - 7000Hz 3 - 7000Hz 3 -5000Hz
Dimensions / mass 12 x 21mm / 12g 15 x 27mm / 23g 15 x 26mm / 26g 15x30mm / 35g
Features Compact General-purpose General-purpose For low acceleration
Appearance
Order No. 820-008 820-009 820-007 820-012
Model No. V301SS V301TA V301TB V301SB
Structure Compression-type Compression-type Compression-type Compression-type
Measuring range 100000m/s
2
100000m/s
2
16000m/s
2
16000m/s
2
Charge sensitivity 3PC / 9.8m/s
2
5PC / 9.8m/s
2
50PC / 9.8m/s
2
50PC / 9.8m/s
2
Natural frequency 70kHz 60kHz 35kHz 35kHz
Frequency range 3 - 15000Hz 3 - 15000Hz 3 - 7000Hz 3 - 7000Hz
Dimensions / mass 10 x 11mm / 2.7g 15 x 23mm / 13g 15 x 30mm / 35g 15 x 30mm / 35g
Features Miniature type For high acceleration General-purpose General-purpose
Appearance
Order No. 820-010 825-159 825-160 820-011
Model No. V301TC V301TD V331TB V313TB
Structure Compression-type Shear-type
Measuring range 10000m/s
2
2500m/s
2
10000m/s
2
10000m/s
2
Charge sensitivity 200PC / 9.8m/s
2
500PC / 9.8m/s
2
50PC / 9.8m/s
2
50PC / 9.8m/s
2
Natural frequency 25kHz 20kHz 30kHz 35kHz
Frequency range 3 - 7000Hz 3 - 5000Hz 3 - 5000Hz 3 - 7000Hz
Dimensions / mass 15 x 35mm / 35g 30 x 41mm / 185g 15 x 44mm / 33g 35 x 35 x 15mm / 45g
Features For low acceleration For low acceleration Water resistance Three-directional
sensitivity axis
Appearance
combination with a variety of vibration
gages, ampliers and other devices.
The measurable frequency range is
wide (several Hz to several kHz) and the
maximum acceleration is high (1000 m/s
2
or more).
V300
SERIES 820, 825 Piezoelectric Type Acceleration Pickup
K-21
FEATURES
The electrokinetics-type speed pickup is
widely used for earthquake observation
and machine vibration. In particular, this
type of detector is regarded as important
equipment in the equipment diagnosis and
other elds because speed measurement is
needed to assess vibration severity required
by the ISO and other standards.
SPECIFICATIONS
Order No. 820-003 820-006 820-004 820-005
Model No. V238J V231 V233 V233
Measurement direction Horizontal and vertical Horizontal and vertical Horizontal Horizontal
Maximum measurement
displacement
1000mp-p 2000mp-p 100mp-p 100mp-p
Sensitivity 100mV/cm/s 100mV/cm/s 100mV/cm/s 100mV/cm/s
Natural frequency 12Hz 12Hz 4.5Hz 4.5Hz
Frequency range 20 - 150Hz 15 - 1000Hz 5 - 200Hz 5 - 200Hz
Dimensions / mass 35 x 80mm / 0.15kg 50 x 110mm / 0.6kg 50 x 110mm / 0.6kg 50 x 110mm / 0.6kg
Features General-purpose General-purpose For low frequency For low frequency
Appearance
Specically, they are generally amplied
to the signal level easy to process in
combination with a variety of vibration
gages, ampliers and other devices.
The measurable frequency range is
relatively wide (several Hz to 1kHz). This is
one of the few vibration pickups that can
directly measure the speed of vibrations.
Order No. 825-105 825-106 825-107 825-108 825-117 825-118 825-140 825-141 825-142 825-143
Model No. U1-FH U1-FH-S U1-FMA V240M V242T
Measurement direction Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical
Maximum measurement
displacement
1000mp-p 1000mp-p 1000mp-p 1000mp-p 1000mp-p
Sensitivity 100mV/cm/s 100mV/cm/s 100mV/cm/s 138mV/cm/s 100mV/cm/s
Natural frequency 12Hz 4.5Hz 7.4Hz 12Hz 4.5Hz
Frequency range 15 - 250Hz 5 - 250Hz 15 - 100Hz 20 - 150Hz 7 - 700Hz
Dimensions / mass 6 x 106 x 155mm / 1.2kg 6 x 106 x 155mm / 1.2kg 60 x 92 x 118mm / 1.5kg 69 x 144 x 100mm / 1.4kg 65 x 125 x 65mm / 0.52kg
Features General-purpose For low frequency Environmental resistance For high temperature
(-10 to +150C)
Equipped with TATE coil
Appearance
Order No. 825-136 825-137 825-145 825-146 825-147 825-148 825-149 825-150
Model No. V235B V241 V241M V241T
Measurement direction Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical
Maximum measurement
displacement
1000mp-p 2000mp-p 1000mp-p 1500mp-p
Sensitivity 100mV/cm/s 1000mV/cm/s 5000mV/cm/s-p 400mV/cm/s
Natural frequency 14Hz 4.5Hz 1Hz 4.5Hz
Frequency range 20 - 250Hz 5 - 500Hz 1.5 - 100Hz 5 - 300Hz
Dimensions / mass 115 x 134 x 170mm / 3.2kg 48 x 48 x 55mm / 0.3kg 48 x 48 x 55mm / 0.3kg 48 x 48 x 55mm / 0.15kg
Features Compression resistance and
explosion protection
For seismic measurement For seismic measurement For seismic measurement
Appearance
V200 and U1
SERIES 820, 825 Electrokinetics-Type Speed Pickup
K-22
FEATURES
The non-contact displacement pickup is
recently becoming common. This detector
directly measures the vibration of a
rotating machine's rotation shaft without
touching it. Specically, vibration is
generally amplied to a signal level which
is easy to process in combination with a
variety of vibration monitoring devices,
ampliers and other devices.
The measurable frequency range is wide
(DC: up to 7kHz) and the detector can
measure displacement. You can also
measure the number of revolutions and
other data using this combination, in
combination with an appropriate amplier.
SPECIFICATIONS
Order No. 825-210 825-209
Model No. V462B-8 V462MX
Measuring range 0 - 3mm 0 - 3mm
Frequency range DC - 10kHz DC - 1kHz
Cable length 300cm 3000cm
Applicable
preliminary
amplier
V460BT V460MX
Dimensions 9 x 40mm 34 x 200mm
Features General-purpose Environmental
resistance
Appearance
FEATURES
This data logger can be used with the
servo-type acceleration pickup V407-3-AT
to congure a mobile observation system
for measuring vibration of bridges and
buildings, as well as earthquake vibrations at
a low cost. Equipped with a trigger function,
this data logger can be also used as a
vibration monitoring system in combination
SPECIFICATIONS
Order No. 820-028
Model No. GPL-02
Analog input No. of channels 8
Input voltage Select 10V, 5V, 2V, 1V, 0 to 1V, 0 to 2V, 0 to 5V, or 0 to 10V (all channels set at
once)
Input impedance 1M or more
AD resolution 12bit
Conversion accuracy 0.5%F.S
Sampling speed 1ch: 100kHz, 2ch: 50kHz, 4ch: 20kHz, 8ch: 10kHz
Digital input No. of input points 8
Input mode No-voltage contact, open collector, TTL level (photo coupler insulated)
Input delay time Up to 50s
No. of I/O points Trigger input: 1, trigger output: 1, digital output: 4
Function I/O Trigger input mode No-voltage contact, open collector, TTL level (photo coupler insulated)
Trigger input delay time Up to 500ns
Trigger output mode Open collector (photo coupler insulated)
Trigger output delay time Up to 500ns
Record mode Chronological data record Record chronological waveforms until the data amount reaches the specied value.
Data recording Sampling cycle Select from 10/20/50/100/200/500s, 1/2/5/10/20/50/100/200/500ms, and 1 to 60s
Data capacity 64MB (standard)
Features Environmental resistance
Trigger type External trigger input, analog input level, digital input
Interface USB ver. 1.1 Full Speed Made (supporting 12Mbps)
Power consumption 8W
Dimensions (W x D x H) 200 x 100 x 36.5 mm (not including projection)
Mass 700g
with the portable vibration gage AVT series.
You can monitor measured waveforms
in realtime in your PC through the USB
interface using the accompanying software.
You can also record these in a memory card
installed in the data logger and reproduce
them in your PC.
V460
SERIES 820, 825 Non-Contact Displacement Pickup
GPL-02
SERIES 820 Data Logger
K-23
FEATURES
This is a handy vibration gage, which is
simple to operate. This device is easy to
grip, allowing you to measure vibration in
one hand because the piezoelectric-type
acceleration pickup is integrated with the
main body.
SPECIFICATIONS
Order No. 820-102
Model No. AHV-1000AZ
Vibration pickup Pezoelectric-type acceleration pickup
Measuring
range
AUTO mode
(automatic sensitivity
switching)
Acceleration: 0.01 - 199.9m/s
2
o--p
Speed: 0.001 - 19.99m/so--p
Displacement: 0.001 - 19.99mmo--p
FIX mode
(sensitivity xed)
Acceleration: 0.1 - 199.9m/s
2
o--p
Speed: 0.01 - 19.99m/so--p
Displacement: 0.01 - 19.99mmo--p
Frequency range 5 to 1,000Hz when high path lter (10Hz) is off 10 to 1,000Hz when high path lter (10
Hz) is on 1,000 to 10,000Hz at bearing check
Accuracy 5% (not including check)
Output (AC output) 1.999Vo-p/F.S (load resistance: 10kor more)
Power Used battery: 9V alkaline battery (006P) x 1 Battery life: Approx. 10hours
Display value hold: 50sec after measurement Automatic power off
Dimensions (W x D x H) 80 x 31 x 185mm
Mass 330g
with optional 60mm
stylus (standard:
15mm stylus)
FEATURES
Adoption of an electrokinetics-type speed
pickup enables you to measure minute
abnormal vibrations even though the
measurements are made through a hand-
held device.
SPECIFICATIONS
Order No. 820-106
Model No. AHV-1000BU
Vibration pickup Pezoelectric-type acceleration pickup
Measuring
range
AUTO mode
(automatic sensitivity
switching)
Acceleration: 0.001 - 19.99m/s
2
o--p
Speed: 0.001 - 19.99cm/s
o--p
Displacement: 0.1 - 1000m p-p
FIX mode
(sensitivity xed)
Acceleration: 0.01 - 19.99m/s
2
o--p
Speed: 0.01 - 19.99cm/so--p
Displacement: 1 - 1000m p-p
Frequency range 8 - 1000Hz
Output (AC output) 1.999Vo-p/F.S (load resistance: 10k or more)
Power Used battery: 9V alkaline battery (006P) x 1 Battery life: Approx. 24hours
Display value hold: 50sec after measurement Automatic power off
Dimensions (W x D x H) 91 x 31 x 192mm
Mass 360g
This gage is best suited to such vibration
measurements where vibration displacement
is large and the acceleration level is
important. Examples include a rolling
bearing.
Since you can also measure abnormal
vibrations of which displacement levels
are small like those of a sliding bearing,
this machine is best suited to vibration
measurement of turbines, motors, and other
equipment.
AHV-1000AZ
SERIES 820 Handy Vibrometer
AHV-1000BU
SERIES 820 Handy Vibrometer
K-24
FEATURES
The handy vibrometer AHV-11A has
achieved a min. reading of 0.1m (min.
speed range reading: 0.001cm/s, min.
acceleration range reading: 0.01 m/s2)
by adopting an electrokinetics-type speed
detector for vibration detection. You
can handle the measuring gage in one
hand throughout measurement. All you
have to do is to grip it, press it against a
measurement point and perform simple
switch operations. Furthermore, this
gage incorporates an operation noise
cut function (patent pending), which
eliminates noise caused by hand jiggling
at the moment of the HOLD switch
operation and validates data immediately
before the switch is pressed. In addition,
you can measure the temperature at
measurement points, in addition to
vibration measurement by using together
with a temperature detector, which is
a sold separately special accessory. This
gage is really helpful when you perform
measurement at several places as this can
store 100 measurement results (vibration
and temperature) together with the date
and time.
The saved data can be sent to computers
(Windows OS) and processed in each
Windows application to easily and quickly
create reports and inspection certicates.
SPECIFICATIONS
Order No. 820-105
Model No. AHV-11A
Vibration pickup Electrokinetics-type speed pickup
Measuring range Acceleration 0.01 - 99.99m/s
2
o--p
Speed 0.001 - 9.999m/so--p
Displacement 0.001 - 999.9mmo--p
Frequency Range 8 - 1000Hz (1 - 3Hz: three-dimensional attenuation)
Characteristics 8 - 20Hz: +10%, -20%
20 - 500Hz: +10%
500 - 1000Hz: +10%,-20%
The reference point is 80 Hz.
Temperature measurement range 0 to 150C, when using an optional temperature detector.
Display Display interval Sampling at 500ms interval
Bar graph 1 to 100% linear full-scale display
Measuring value Displacement, speed acceleration, and temperature
Overload display (-E-)
Indication characteristic RMS1, RMS2, and PEAK positions.
Measurement mode mp-p, cm/so-p, m/s
2
o-p, and C
Memory address 0 to 99 (100 data items)
Remaining battery level Two-level bar graph display
Date Alternation of date or time at 10-second intervals
Memory contents Date, time, vibration level, indication characteristic, measurement mode,
temperature (when using the temperature detector)
Output AC output 1 Vo-p/F.S (impedance: about 100or more)
DC output 1 V/F.S (impedance: about 100or more)
Input Temperature detector Detection accuracy: 3% FS (when using Order No. 820-025)
Interface Output Memory data
Input Date function setting
Power Used battery: 9V alkaline battery (006P) x 1
Battery life: Approx. 14hours
Optional AC adapter supported
Dimensions (W x D x H) 82 x 40 x 234mm
Mass About 420 g (inclusive of the battery)
AHV-11A
SERIES 820 Handy Vibrometer
K-25
FEATURES
Pezoelectric-type acceleration pickups
can be replaced with different measuring
range types for a variety of applications,
from bearing vibration to general industrial
equipment. Highly accurate measurements
SPECIFICATIONS
Order No. 820-113
Model No. AVT-CZ
Vibration pickup Pezoelectric-type acceleration pickup
Measuring range Acceleration Frequency range 5 - 5000Hz
Range (F.S) 1, 3, 10, 30, 100m/s
2
o-p (minimum reading: 0.02m/s
2
o-p)
Speed Frequency range 10 - 1000Hz
Range (F.S) 0.1, 0.3, 1, 3, 10cm/so-p (minimum reading: 0.002cm/s
2
o-p)
Displacement Frequency range 10 - 1000Hz
Range (F.S) 0.1, 0.3, 1, 3, 10mmp-p (minimum reading: 0.002mm/s
2
o-p)
Bearing vibration Frequency range 1000 - 5000Hz
Range Equivalent to A (1), B (3), C (10), D (30), E (100 m/s
2
)
Output AC output: 1Vo-p/F.S, DC output: 1V/F.S
Power 9V alkaline battery (006P) x 2
Dimensions (W x D x H) 100 x 52 x 188mm
Mass 480g (including the battery, but not the pickup)
FEATURES
This is an easy-to-operate battery-powered
compact vibration gage. This general-
purpose gage has a wide measuring range
that covers most vibrations from general
industrial machines. It can provide extremely
accurate measurements by switching
SPECIFICATIONS
Order No. 820-112
Model No. AVT-B2
Vibration pickup Pezoelectric-type acceleration pickup
Measuring range Acceleration Frequency range Depending on the detector
Range (F.S) 1, 3, 10, 30, 100m/s
2
o-p (minimum reading: 0.002m/s
2
o-p)
Speed Frequency range Depending on the detector
Range (F.S) 0.1, 0.3, 1, 3, 10cm/so-p (minimum reading: 0.002cm/s
2
o-p)
Displacement Frequency range Depending on the detector
Range (F.S) 10, 30, 100, 300, 1000mp-p (minimum reading: 0.2m/
sp-p)
Bearing vibration Frequency range Depending on the detector
Range Equivalent to A (1), B (3), C (10), D (30), E (100 m/s
2
)
Output AC output: 1Vo-p/F.S, DC output: 1V/F.S
Power 9V alkaline battery (006P) x 2
Dimensions (W x D x H) 100 x 52 x 188mm
Mass 460g (including the battery, but not the pickup)
can be performed by selecting a detector
appropriate for your application, from low
frequency and minor displacement through
high frequency and large acceleration.
among the ve-level sensitivity ranges for
the displacement, speed, and acceleration.
Adoption of the electrokinetics-type speed
detector makes it best for displacement
vibration and speed vibration measurement.
AVT-CZ
SERIES 820 Universal Vibrometer
AVT-B2
SERIES 820 Universal Vibrometer
K-26
FEATURES
This is a handy three-dimensional vibration
gage with superior functionality.
When vibration of motors, pumps, or
bearings is measured, three directions
(vertical, horizontal, and bearing) are
measured. The AVT-3000DZ can individually
detect vibration components in three
directions (X, Y, and Z) using a single pickup.
This gage can also measure a realtime
combined value of three elements.
FEATURES
Employing a sensitive servo-type acceleration
pickup for earthquake measurement,
these meters are best suited to measure
vibration of oors, bridges, marine internal
combustion engines, and other equipment
that a general vibration gage would have
difculty measuring. In particular, these
meters are extremely useful when evaluating
vibration impact on the installation
environment for precision measurement and
processing equipment
SPECIFICATIONS
Order No. 820-111
Model No. AVT-3000 DZ
Vibration pickup 3-axis pezoelectric-type acceleration pickup-type acceleration pickup
Measuring mode Single axis (X, Y, Z): Acceleration, speed, and displacement
Combined 3 axes: Acceleration
Bearing check: Acceleration
Measuring range Acceleration Frequency range 3 - 5000Hz
Range (switching) 0.01 - 199.9m/s
2
o-p
Speed Frequency range 10 - 5000Hz
Range (switching) 0.001 - 19.99cm/so-p
Displacement Frequency range 10 - 1000Hz
Range (switching) 0.001 - 19.99mmp-p
Bearing vibration Frequency range 1000 - 10000Hz
Range (switching) 0.01 - 19.99mm/s
2
p-p
Output AC output: 1Vo-p/F.S, DC output: 1V/F.S
Power 9V alkaline battery (006P) x 2
Dimensions (W x D x H) 100 x 43 x 188mm
Mass 600g (including the battery, but not the pickup)
SPECIFICATIONS
Order No. 820-103 820-104
Model No. AVT-103 AVT-104
Vibration pickup Servo-type acceleration pickup
Vertical/horizontal
Measuring range Displacement Frequency range 0.5 - 20HzHz
Range (F.S) 10, 30, 100, 300, 1000mo-p (minimum reading: 0.2mp-p)
Acceleration Frequency range 0.5 - 50Hz 0.5 - 200Hz
Range (F.S) 1, 3, 10, 30, 100Gal (minimum reading: 0.02Gal)
Acceleration (L) Frequency range 0.5 - 50Hz
Range (F.S) 1, 3, 10, 30, 100Gal
(minimum reading: 0.02Gal)
Output AC output: 3Vo-p/F.S
DC output: 3V/F.S
Power 9V alkaline battery (006P) x 2
Dimensions (W x D x H) Main unit: 100 x 52 x 188mm, Pick up: 45 x 45 x 90mm
Mass Main unit: 490g (including the battery), Pick up: 725g
AVT-3000DZ
SERIES 820 Universal Vibrometer
AVT-103 / AVT-104
SERIES 820 Ground Noise Meters
K-27
SPECIFICATIONS
Order No. 820-001
Model No. AVT-SB
Applied model AVT-CZ, AVT-B2, AVT-103, AVT-104,
AVT-3000DZ (not available for the 3D measuring mode)
Filter function Low path lter (LPF): Second Butterworth
High path lter (HPF): Second Butterworth
Band path lter (BPF): Q = approx. 10
Frequency range selection 10 to 5,000Hz (Accuracy is not guaranteed if the frequency is more than 5,000Hz.)
Accuracy I/O accuracy: 5%F.S.
Frequency dial value accuracy: 5% dial value 0.5 graduation
Output 0.1 V output (frequency dial value: 10Hz), 1 V output (frequency dial value: 100Hz)
Power Powered from the main body (AVT-3000DZ, AVT-CZ, AVT-B2, AVT-103, AVT-104) (9 V)
Dimensions (D x W x H) 100 x 52 x 105mm
Mass 310g
SPECIFICATIONS
Order No. 820-002
Model No. AVT-PS
AC adapter function Applied model AVT-3000DZ, AVT-CZ, AVT-B2, AVT-103, AVT-104
Battery charger function Applied model AVT-3000DZ
Ni-Cd battery 8.4V 100mAh
Charging time Approx. 8hrs.
Ni-Cd battery life Approx. 5hrs.
Power AC100V 50/60Hz
Dimensions (W x D x H) 100 x 52 x 105mm
Mass 350g
FEATURES
This is a vibration analyzer for the universal
vibrometer AVT series.
This analyzer can be used as a low path
lter, high path lter, and band path lter
by connecting to the AVT series vibration
gage. In addition as an application
of a band path lter, the frequency
characteristics of measurement vibration
can be obtained by using with an X-Y
recorder.
AVT-SB
SERIES 820 Vibration Analyzer
FEATURES
This is an AC adapter/Ni-Cd battery charger
for the universal vibrometer AVT series*.
*except for AVT-B2, AVT-CZ, AVT-103, and AVT-104
AVT-PS
SERIES 820 Vibration Analyzer
FEATURES
This machine always monitors vibration
and can be used for a wide range of
purposes. For example, you can trigger
an alarm or stop machine operation in an
emergency if an abnormality occurs.
AVR Series
Vibration Monitoring Machine
This is best suited to continuous monitoring
of vibration of large turbines in thermal,
hydro, nuclear, and other power plants.
K-28
www.mitutoyo.com
The new 2007 Catalog is
available on-line
At www.mitutoyo.com you can nd:
Company Information
Complete Product Information
Product Literature
Sales and Promotions
Distributor Locator
Support Services and Contacts
Knowledge Bases
Frequently Asked Questions (FAQs)
Education Services
We want to provide our customers with the very best
Metrology products, services and information that they can
nd anywhere. Find it all in one easy to reach location at
www.mitutoyo.com.
Get up to date product information for over 5000 Mitutoyo
products. See the latest sales and promotions and access
a variety of product services from one sourcewhen you
need it.
You want the best. You want it fast. Come see what we
have to offer at: www.mitutoyo.com
For Canada visit: www.mitutoyo.ca