Inverter technology Indoor air quality Design and control Matching tables Super Daiseikai Suzumi GKHP Fixed speed indoor units Multi-split systems GDV/SM_UV Multi-split indoor units GAV Multi-split outdoor units Combination ratings Technical tables

4 6 8 10 11 12 13 14 15 16 17 20

The sum of perfection


Air conditioning plays a fundamental role in your well-being at home as well as at work. It not only achieves the desired temperature, it also increases your indoor air quality. Selecting the most suitable system is key to maximising performance and optimising comfort. Air treatment, low sound levels, guaranteed energy savings and easy installation of the indoor units make the Toshiba residential range the top choice for any home. We know that a perfect unit is the sum of perfection in every detail. Solutions that are studied and verified in every tiny element are recognised universally by air conditioning professionals for their total reliability.

Well-being and beyond


All Toshibas R-410A residential products have been designed to offer the best possible comfort to users. The air filtration systems provide filtered indoor air at all times. In fact, the high-wall units grant high energy savings and unmatched indoor air quality. Thanks to a modern design, the indoor units also look elegant and blend beautifully with any room interior. They incorporate all the features a user can require: silent, discreet and unobtrusive, they deliver high energy efficiency and complete air purification.

Residential

A passion for innovation


Toshiba was the first company to incorporate inverter technology into air conditioning systems in 1981, and since then it has always maintained a technological advantage over its competitors. The development of the new and exclusive DC hybrid inverter system has reaffirmed this ability to innovate and maintain technological leadership in a fast-growing market. But for Toshiba, innovation also means a strong commitment to international institutions that carefully evaluate the impact of new technologies on our environment. Toshiba combines technological development with care for future generations: the result is a range of extremely energy-efficient air conditioners, reducing greenhouse gas emissions at source. Toshibas continuous research developed PWM technology, which is used together with the traditional PAM control. The application of these two distinct technologies allows total control of performance and energy use.

The ultimate expression of inverter technology


Toshiba DC hybrid inverter technology controls the capacity supplied by the air conditioner. By modifying the supply current frequency or intensity, it ensures smooth linear variation of the rotation speed and capacity of the compressor the heart of the air conditioner. This allows the cooling and heating capacities to be matched to the actual operating conditions required. When the room temperature is different from the set point temperature or desired temperature, the air conditioner operates at maximum capacity, ensuring that a comfortable temperature will be reached quickly. Once the desired temperature is reached, the inverter precisely adjusts the capacity to maintain a stable temperature close to the set point.

Filtration, purification, innovation: excellent indoor air quality


True quality in the residential environment goes beyond control of the air filtration. With Toshiba residential air conditioners, air quality is guaranteed by many stages of filtration and additional functions such as pre-treatment, removal of fine particles, viruses, bacteria and allergens for total purification. Electrostatic purification also guarantees a basic cost advantage, as there are no ongoing replacement part costs. Thanks to a complete and exceptional air treatment process, a pure and healthy environment is assured. Furthermore, the high-walls are equipped with special filtration systems that remove odours and pollutants and prevent mould formation, granting enhanced indoor air quality and perfect comfort in the home.

Nothing escapes a Toshiba filter!


Plasma Air Purifier The Plasma Air Purifier absorbs and eliminates particles and pollutants such as dust, pollen, mould spores and viruses. It also deodorises air (removing tobacco odours, garbage smells etc.). Its extremely effective: it can collect particles as small as 0.001 m and is 10 times faster than standard filters. This is a combination of Coffee Bean extract, Vitamin C and Super Zeolite filters. It works as Anti Oxidant and deodoriser. Coffee Bean has anti-aging and antioxidant properties. Vitamin C protects skin by neutralising free radicals that could harm skin and its components. Super Zeolite (combining Zeolite and Titanium Dioxide) deodorises and cleans the air, removing chemicals and odours. This is a complete system, comprising Super Ginko, Byo Enzyme and Sasa filters. Super Gingko reduces agents that can cause allergic reactions. Bio Enzyme traps and removes bacteria, viruses and mould. Sasa (Bamboo grass) is effective in deactivating bacterial viruses that cause illness. Super Oxi Deo Super Sterilizer

Super Oxi Deo filter (front)

Bio-enzyme & Gingko filter (front)

Super Oxi Deo filter (back)

Bio-enzyme & Gingko filter (back)

The perfect answer from the experts


Toshiba has been studying, designing and creating innovative air conditioning systems for over 30 years and as a result can offer the highest performance on the market. Following this philosophy, Toshiba has always succeeded in creating products that provide top performance, active air purification, superior COP and extraordinary energy savings.

Good news for our wallet!


Quality has always been Toshibas strength and will remain the trademark that will differentiate Toshiba air conditioners from those of other manufacturers. Toshiba products offer exceptional performance. In addition, since the government introduced energy labeling to highlight the actual energy consumption of goods, Toshiba products proudly display, in the main, the precious green A. This means high energy savings!

Good news for the environment!


Toshiba has anticipated legislation on the control of refrigerant emissions to the atmosphere and, to show its clear commitment to respecting the environment, it is carrying out continuous research and improvement. Toshibas residential systems use only R-410A, the high efficiency non-ozone depleting refrigerant.

The style of technology


Toshiba has always paid attention to aesthetics and design, particularly for residential products. We know that the end users are looking for a sophisticated system that is also reliable, efficient and quiet. Technology needs to be combined with design. Following this philosophy, Toshiba created compact and unobtrusive residential indoor units that blend with any room interior. The high-walls are very stylish and modern; thanks to the flat panels and the elegant details, the units suit any kind of interior decor. The flexi unit is totally unobtrusive: it can be installed in two positions, either at low floor level like a radiator or beneath the ceiling. It has an elegant profile, making it suitable for many rooms.

The importance of being silent


Knowing the importance of low noise levels for the user, we have created unobtrusive and discreet systems, able to operate without any disturbance, for your family and your neighbours. In fact, Toshiba managed to achieve very low noise levels for both the indoor and the outdoor units, granting absolute and total comfort.

All the functions of your comfort


In order to offer total and exceptional comfort to our customers, Toshiba has always tried to create the most complete and advanced remote control, able to meet the highest expectations. To achieve this challenging objective, extensive market research has been carried out to highlight the preferred settings of European users. In this way, enhanced and personalised comfort is granted.

One Touch Personal Comfort: there


is no need to select any setting Toshiba has already memorised the preferred setting, changeable, should you so desire. store their preferred settings (operating mode, temperature, timer, louver, fan speed and hipower).

Auto Diagnosis: this is a system

that constantly monitors functions and components and makes maintenance very easy. possible to have comfort combined with energy savings (up to 25% compared to standard operation). desired temperature is quickly reached.

One Touch Preset: users can easily

Eco-logic: with this function, it is Hi-Power: with extra air flow the

Quiet mode: the indoor unit will

operate at ultra low fan speed, reaching extraordinary low noise levels.

Super Daiseikai

Suzumi

GKV Inverter high-wall GKHP Fixed-speed high-wall GDV Inverter ducted

10
Residential range - single-split systems
OUTDOOR UNIT:

sizes
Inverter

10

13

16

18

24

RAS-10SAVP-E RAS-B10SKVP-E

RAS-13SAVP-E RAS-B13SKVP-E

RAS-16SAVP-E RAS-B16SKVP-E

RAS-10SAV-E RAS-10SKV-E

RAS-13SAV-E RAS-13SKV-E

RAS-16SAV-E RAS-16SKV-E

Fixed-speed

RAS-10GAH-ES2 RAS-10GKHP-ES2

RAS-13GAH-ES2 RAS-13GKHP-ES2

RAS-18GAH-ES2 RAS-18GKHP-ES2

RAS-24GAH-ES2 RAS-24GKHP-ES2

Residential range - multi-split systems


Heat Pump systems

2 rooms
OUTDOOR UNIT: RAS-M14GAV-E RAS-M18GAV-E

3 rooms
RAS-3M26GAV-E

4 rooms
RAS-4M27GAV-E

sizes 10 & 13

sizes 10, 13 & 16

sizes 10, 13 & 16

sizes 10, 13 & 16

SKVP

sizes 10 & 13

sizes 10, 13 & 16

sizes 10, 13 & 16

sizes 10, 13 & 16

SKV

sizes 10 & 13

sizes 10, 13 & 16

sizes 10, 13 & 16

sizes 10, 13 & 16

GDV

sizes 10, 13 & 16

sizes 10, 13 & 16

sizes 10, 13 & 16 (permitted with conditions)

SM_UT

SKVP
AG+ PLASMA AIR PURIFIER SINGLE/MULTI-SPLIT DC HYBRID INVERTER

11

Super Daiseikai The third generation of Daiseikai perfection


Savings With its A/A class and an EER of 5.1 (size 10), this high-wall is a supreme champion in energy saving: 35% more than a standard A-class inverter. In addition, thanks to its twin-rotary compressor, it can operate at very low speeds (minimum cooling capacity is 0.5 kW), consuming only 100 W. purification This exceptional indoor unit is equipped with an Ag + Plasma Air Purifier, a complete filtration system that deodorises air, removes bacteria and provides a pure and healthy environment.

... and design! With its compact dimensions and its modern design, the Super Daiseikai is very discreet and unobtrusive. Its exclusive silver sides give it an additional touch of elegance.

Technical specifications single/multi-split heat pump


Outdoor unit Indoor unit* Cooling capacity EER Energy efficiency class, cooling Heating capacity COP Energy efficiency clas, heating Indoor unit Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) dB(A) dB(A) dB(A) dB(A) mm kW W/W kW W/W RAS-10SAVP-E RAS-B10SKVP-E 2.50 5.10 A 3.20 5.08 A RAS-B10SKVP-E 42/27 57/42 43/27 58/42 250 790 208 RAS-13SAVP-E RAS-B13SKVP-E 3.50 4.12 A 4.20 4.42 A RAS-B13SKVP-E 43/27 58/42 44/27 59/42 250 790 208 RAS-16SAVP-E RAS-B16SKVP-E 4.50 3.33 A 5.50 3.69 A RAS-B16SKVP-E 45/29 60/44 45/29 60/45 250 790 208

See the complete technical table on page 20

12

SKV

PURE INDOOR AIR WITH 7 IN 1 FILTRATION SYSTEM SINGLE/MULTI-SPLIT A/A CLASS DC ROTARY INVERTER

Suzumi High quality and savings


This inverter high-wall operates at the lowest sound levels in its category. It is A-class (for both sizes 10 and 13) and, with the DC rotary Inverter, it provides high energy savings: 20% more than a standard A-class fixedspeed model.

Purity without compromise! Toshibas 7-in-1 filtration system helps stop impurities from reaching you and your family. With this advanced system, the air passes through several filters and becomes purer, fresher and healthier, ensuring optimised comfort in your home.

Vitamin C neutralises free radicals


that could harm skin

Super Zeolite removes odours Coffee bean has anti-oxidant


properties

Super Gingko reduces agents that


cause allergic reactions viruses and mould viruses

Bio Enzyme removes bacteria, Sasa helps deactivate bacterial

Technical specifications single/multi-split heat pump


Outdoor unit Indoor unit Cooling capacity EER Energy efficiency class, cooling Heating capacity COP Energy efficiency class, heating Indoor unit Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) dB(A) dB(A) dB(A) dB(A) mm kW W/W kW W/W RAS-10SAV-E RAS-10SKV-E 2,50 3,33 A 3,20 3,72 A RAS-10SKV-E 38/29 51/42 40/30 53/43 250 740 195 RAS-13SAV-E RAS-13SKV-E 3,50 3,27 A 4,20 3,72 A RAS-13SKV-E 39/26 52/39 40/28 53/41 275 790 205 RAS-16SAV-E RAS-16SKV-E 4,50 2,82 C 5,30 3,42 B RAS-16SKV-E 45/30 58/43 45/31 58/44 275 790 205

See the complete technical table on page 21

Fixed speed indoor units


EFFICIENT AIR FILTRATION SYSTEM COMPACT AND ELEGANT HI-POWER AND AUTO DIAGNOSIS FUNCTIONS

13

GKHP Fixed-speed high-wall Elegant and efficient unit


This high-wall is compact and slimline and easily blends with any interior decor. It is the slimmest unit in the Toshiba range: 25% smaller and 30% lighter (for sizes 7 and 10). It is equipped with a complete and efficient filtration system, that includes Zeolite Plus, Sasa filters and the Vitamin C filter, which has useful anti-oxidant properties.

Technical specifications heat pump


Outdoor unit Indoor unit Cooling capacity EER Energy efficiency class, cooling Heating capacity COP Energy efficiency class, heating Outdoor unit Sound pressure level, cooling/heating Sound power level, cooling/heating Dimensions (H x L x D) kW W/W kW W/W RAS-10GAH-ES2 RAS-10GKHP-ES2 2.73 3.25 A 2.94 3.63 A RAS-10GAH-ES2 47/47 60/60 550 780 290 RAS-13GAH-ES2 RAS-13GKHP-ES2 3.78 3.23 A 4.23 3.65 A RAS-13GAH-ES2 49/49 62/62 550 780 290 RAS-18GAH-ES2 RAS-18GKHP-ES2 5.03 2.68 D 5.50 3.20 C RAS-18GAH-ES2 52/53 65/66 550 780 290 RAS-24GAH-ES2 RAS-24GKHP-ES2 6.30 2.55 E 6.85 2.81 D RAS-24GAH-ES2 56/57 69/70 715 780 290

dB(A) dB(A) mm

Technical specifications heat pump


Indoor unit Sound pressure level (h/l) Sound power level (h/l) Dimensions (H x L x D) Outdoor unit Operating range, cooling Operating range, heating dB(A) dB(A) mm C C RAS-10GKHP-ES2 41/31 54/44 250 740 185 RAS-10GAH-ES2 15 to 43 10 to 24 RAS-13GKHP-ES2 41/31 54/44 275 790 218 RAS-13GAH-ES2 15 to 43 10 to 24 RAS-18GKHP-ES2 44/35 57/48 298 998 220 RAS-18GAH-ES2 15 to 43 10 to 24 RAS-24GKHP-ES2 45/37 58/50 298 998 220 RAS-24GAH-ES2 15 to 43 10 to 24

See the complete technical table on page 22

14

Technology in multi-split systems

For premises that require air conditioning in more than one room, the Toshiba multi-split system is the ideal solution. One outdoor unit is capable of operating two, three or four indoor units. They are compact and elegant and designed to blend in with any room interior. Toshiba offers a wide range of possibilities to create all the comfort you desire. The full range of indoor units can satisfy every kind of need: it includes unobtrusive ducted units and modern high walls, that provide high-tech, sophisticated design and complete air filtration at the same time. The efficient inverter systems are composed of high quality components: control electronics, motor, compressor. Toshiba solutions are universally recognised by air conditioning professionals for their total reliability.

Multi-split indoor units


LOW NOISE LEVELS MULTI-SPLIT SLIM DESIGN FOR AN EASY AND FLEXIBLE INSTALLATION

15

GDV Inverter ducted Reliable and unobtrusive solution


This ducted multi-split inverter unit offers reliable and controllable comfort all year round. It is compact (only 230 mm high) and operates quietly, granting optimum and absolute well-being: with one outdoor unit serving up to four indoor units. The indoor units ensure immediate comfort and total discretion. An easy-to-use infra-red remote control allows a complete control. A wired control is available as an option.

heat pump system


Indoor unit Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight m3/h (l/s) dB(A) dB(A) m3/h (l/s) dB(A) dB(A) mm kg RAS-M10GDV-E 720/400 (200/111) 31/23 44/36 720/400 (200/111) 32/24 45/37 230 750 440 19 RAS-M13GDV-E 780/428 (217/119) 32/24 45/37 780/428 (217/119) 33/25 46/33 230 750 440 19 RAS-M16GDV-E 780/428 (217/119) 33/25 46/38 780/428 (217/119) 34/26 47/34 230 750 440 19

STYLISH DESIGN AND COMPACT DIMENSIONS, TO SUIT ALL STANDARD GRIDS MULTI-SPLIT EASY MAINTENANCE

SM_UV New inverter cassette Compact and discreet


This new four-way cassette has been designed to suit all the standard 600 600 mm grid ceilings, for easy installation and maintenance, thanks also to the simple access to the electrical box by removing the suction grille. Its compact and stylish panel design makes this unit discreet and unobtrusive. The cassette is equipped with infrared remote control, as standard.

heat pump system


Indoor unit Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight m3/h ( l/s) dB(A) dB(A) m3/h (l/s) dB(A) dB(A) mm kg RAS-M10SMUV-E 588/432 (163/120) 37/30 52/45 588/432 (163/120) 37/30 52/45 268 575 575 15 RAS-M13SMUV-E 618/432 (172/120) 38/30 53/45 618/432 (172/120) 38/30 53/45 268 575 575 15 RAS-M16SMUV-E 660/450 (183/125) 40/31 55/46 660/4550 (183/125) 40/31 55/46 268 575 575 15

See the complete technical table on page 23

16

R-410A DC HYBRID INVERTER MULTI-SPLIT

GAV Multi-split outdoor unit Multiplied technology and comfort


Toshiba multi-split outdoor units are equipped with the Toshiba DC hybrid inverter, an enhanced feature that ensures improved performance and reliability. Thanks to the efficient DC compressors, these units provide fast and precise temperature management, with energy savings of 40-50% compared to fixedspeed systems. These flexible condensing units can be matched with a wide range of indoor units: high-walls (including Super Daiseikai), ducted and the new 600 600 mm cassette.

2 Rooms

Super Daiseikai SKVP

M-SKV

3 Rooms

4 Rooms

Super Daiseikai SKVP

Super Daiseikai SKVP

Super Daiseikai SKVP

four-way cassette M-SM_UV M-SKV

M-GDV (Ducted) Four-way cassette M-SM_UV

See the complete technical table on page 24

17
Combination ratings heat pump
Cooling, 230 V Size 14 14 Heating, 230 V Size 14 14 Operating status 1 unit operation 2 unit operation Operating status 1 unit operation 2 unit operation Unit A 10 13 10 13 Combination Unit C Unit B 10 10 Unit D Unit A 2.50 3.50 1.95 2.33 Unit capacity (kW) Unit C Unit B 1.95 1.67 Unit D Cooling capacity (kW) Min. Rated Max. 1.1 2.5 3.2 1.1 3.5 3.8 1.4 3.5 4.4 1.4 4.0 4.5 Heating capacity (kW) Min. Rated Max. 0.7 3.2 4.0 0.7 4.2 4.4 0.9 4.3 4.6 0.9 4.4 4.7 Power input (W) Rated 570 1100 1070 1080 Power input (W) Rated 850 1250 980 1010

Outdoor unit: RAS-M14GAV-E

Combination Unit C Unit D Unit A Unit B 10 13 10 10 13 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E

Unit capacity (kW) Unit C Unit D Unit A Unit B 3.20 4.20 2.15 2.15 2.50 1.90 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E

Cooling, 230 V Size

Operating status Unit A 10 13 16 10 13 13 16

18

1 unit operation

18 Heating, 230 V Size

2 unit operation

Combination Unit C Unit B 10 10 13 10 -

Unit D -

Unit A 2.70 3.70 4.50 2.55 3.01 2.60 3.25

Unit capacity (kW) Unit C Unit B 2.55 2.19 2.60 1.95 -

Unit D -

Cooling capacity (kW) Min. Rated Max. 1.1 2.7 3.2 1.1 3.7 4.2 1.1 4.5 4.9 1.4 5.1 6.1 1.4 5.2 6.2 1.4 5.2 6.2 1.4 5.2 6.2 Cooling capacity (kW) Min. Rated Max. 0.7 4.0 5.2 0.7 5.0 6.5 0.7 5.5 6.9 0.9 6.4 8.3 0.9 6.7 8.7 0.9 6.7 8.7 0.9 6.7 8.7 Cassette RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E

Power input (W) Rated 600 1100 1500 1550 1600 1600 1600 Power input (W) Rated 1200 1800 1900 1800 1850 1850 1850

Operating status

18

1 unit operation

18

2 unit operation

Outdoor unit: RAS-M18GAV-E

Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 13 13 16 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E

Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.20 3.20 3.72 2.98 3.35 3.35 3.88 2.82 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E

18

Combination ratings heat pump


Cooling, 230 V Size Operating status Unit A 10 13 16 10 13 16 13 16 16 10 13 16 13 16 13 16 16 16 Combination Unit C Unit B 10 10 10 13 13 16 10 10 10 10 10 10 13 10 13 10 13 13 16 10 13 13 16 13 Unit D Unit A 2.70 3.70 4.50 2.70 3.41 3.94 3.15 3.73 3.60 2.47 3.01 3.36 2.71 3.10 2.50 2.88 2.84 2.66 Unit capacity (kW) Unit C Unit B 2.70 2.49 2.36 3.15 3.07 3.60 2.47 2.47 2.20 2.20 2.02 2.02 2.71 1.98 2.55 1.86 2.50 2.50 2.88 1.73 2.33 2.33 2.66 2.19 Unit D Cooling capacity (kW) Min. Rated Max. 1.4 2.7 3.2 1.4 3.7 4.4 1.4 4.5 5.0 2.5 5.4 6.3 2.7 5.9 6.6 2.9 6.3 6.9 2.9 6.3 6.9 3.0 6.8 7.2 3.2 7.2 7.5 3.6 7.4 8.2 3.9 7.4 8.3 4.0 7.4 8.5 4.0 7.4 8.5 4.0 7.5 8.6 4.0 7.5 8.6 4.1 7.5 8.8 4.1 7.5 8.8 4.2 7.5 8.9 Cooling capacity (kW) Min. Rated Max. 0.8 4.0 5.2 0.8 5.0 6.5 0.8 5.5 6.9 1.5 7.2 10.0 1.5 7.6 10.1 1.5 7.9 10.1 1.5 7.9 10.1 1.5 8.3 10.2 1.5 8.6 10.2 2.0 8.6 10.4 2.0 8.7 10.5 2.0 8.8 10.6 2.0 8.8 10.6 2.0 8.8 10.6 2.0 8.8 10.6 2.0 8.9 10.7 2.0 8.9 10.7 2.09.0 10.8 Cassette RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E Power input (W) Rated 750 1200 1650 1530 1810 2040 2040 2320 2550 2230 2230 2230 2230 2250 2250 2250 2250 2250 Power input (W) Rated 1500 2050 2400 2050 2240 2380 2380 2560 2700 2300 2360 2430 2430 2430 2430 2490 2490 2550

26

1 unit operation

26

2 unit operation

26

3 unit operation

Heating, 230 V Size

Operating status

26

1 unit operation

26

2 unit operation

26

3 unit operation

Outdoor unit: RAS-M26GAV-E

Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 16 10 13 13 16 13 16 16 10 10 10 13 10 10 16 10 10 13 13 10 16 13 10 13 13 13 16 16 10 16 13 13 16 16 13 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E

Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.60 3.60 4.22 3.38 4.57 3.33 3.95 3.95 4.35 3.95 4.30 4.30 2.87 2.87 2.87 3.35 2.68 2.68 3.59 2.61 2.61 3.14 3.14 2.51 3.34 3.03 2.43 2.93 2.93 2.93 3.26 3.26 2.37 3.16 2.87 2.87 3.09 3.09 2.81 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E

19

Combination ratings heat pump


Cooling, 230 V Size Operating status Unit A 10 13 16 10 13 16 13 16 16 10 13 16 13 16 13 16 16 16 16 10 13 16 13 16 13 16 13 16 Combination Unit C Unit B 10 10 10 13 13 16 10 10 10 13 13 13 16 13 16 16 10 10 10 13 13 13 13 13 16 10 10 10 10 10 13 10 13 13 16 10 10 10 10 10 13 13 13 10 Unit D 10 10 10 10 10 10 10 13 10 Unit A 2.70 3.70 4.50 2.70 3.41 3.94 3.15 3.73 3.60 2.63 3.13 3.50 2.82 3.22 2.60 3.04 2.99 2.80 2.87 1.98 2.48 2.86 2.31 2.65 2.14 2.47 2.00 2.50 Unit capacity (kW) Unit C Unit B 2.70 2.49 2.36 3.15 3.07 3.60 2.53 2.28 2.10 2.82 2.85 2.60 3.04 2.46 2.80 2.67 1.98 1.81 1.71 2.31 2.18 2.14 2.03 2.00 2.50 2.53 2.28 2.10 2.06 1.93 2.60 1.82 2.46 2.30 2.67 1.98 1.81 1.71 1.69 1.59 2.14 2.03 2.00 1.50 Unit D 1.98 1.81 1.71 1.69 1.59 1.57 1.48 2.00 1.50 Cooling capacity (kW) Min. Rated Max. 1.4 1.4 1.4 2.5 2.7 2.9 2.9 3.0 3.2 3.6 3.9 4.0 4.0 4.1 4.1 4.1 4.1 4.2 4.3 4.0 4.1 4.1 4.1 4.2 4.2 4.2 4.2 4.2 2.7 3.7 4.5 5.4 5.9 6.3 6.3 6.8 7.2 7.6 7.7 7.7 7.7 7.8 7.8 7.9 7.9 7.9 8.0 7.9 7.9 8.0 8.0 8.0 8.0 8.0 8.0 8.0 3.2 4.4 5.0 6.3 6.6 6.9 6.9 7.2 7.5 8.2 8.3 8.5 8.5 8.6 8.6 8.7 8.7 8.9 9.0 8.7 8.8 9.0 9.0 9.1 9.1 9.2 9.2 9.2 Power input (W) Rated 750 1200 1650 1530 1810 2040 2040 2320 2550 2400 2410 2410 2410 2430 2430 2440 2440 2440 2450 2450 2450 2500 2500 2500 2500 2500 2500 2500 Power input (W) Rated 1450 2050 2400 2100 2320 2480 2480 2700 2860 2300 2350 2350 2350 2400 2400 2450 2450 2450 2500 2100 2100 2250 2250 2250 2250 2250 2250 2250

27

1 unit operation

27

2 unit operation

27

3 unit operation

27

4 unit operation

Heating, 230 V Size

Operating status

27

1 unit operation

27

2 unit operation

27

3 unit operation

27

4 unit operation

Outdoor unit: RAS-M27GAV-E

Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 16 10 13 13 16 13 16 16 10 10 10 13 10 10 16 10 10 13 13 10 16 13 10 13 13 13 16 16 10 16 13 13 16 16 13 16 16 16 10 10 10 10 13 10 10 10 16 10 10 10 13 13 10 10 16 13 10 10 13 13 13 10 16 13 13 10 13 13 13 13 16 16 10 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E

Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.60 3.60 4.22 3.38 4.57 3.33 3.95 3.95 4.35 3.95 4.30 4.30 2.87 2.87 2.87 3.35 2.68 2.68 3.54 2.58 2.58 3.11 3.11 2.49 3.34 3.03 2.43 2.93 2.93 2.93 3.26 2.26 2.37 3.16 2.87 2.87 3.06 3.06 2.78 3.00 3.00 3.00 2.23 2.23 2.23 2.23 2.62 2.09 2.09 2.09 2.83 2.06 2.06 2.06 2.50 2.50 2.00 2.00 2.68 2.43 1.95 1.95 2.37 2.37 2.37 1.89 2.54 2.31 2.31 1.85 2.25 2.25 2.25 2.25 2.61 2.61 1.89 1.89 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E

Cooling capacity (kW) Min. Rated Max. 0.8 4.0 5.2 0.8 5.0 6.5 0.8 5.5 6.9 1.5 7.2 10.0 1.5 7.6 10.1 1.5 7.9 10.1 1.5 7.9 10.1 1.5 8.3 10.2 1.5 8.6 10.2 2.0 8.6 10.4 2.0 8.7 10.5 2.0 8.7 10.5 2.0 8.7 10.5 2.0 8.8 10.6 2.0 8.8 10.6 2.0 8.9 10.7 2.0 8.9 10.7 2.0 8.9 10.7 2.2 9.0 10.8 2.2 8.9 10.8 2.2 8.9 10.9 2.2 9.0 10.9 2.2 9.0 10.9 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 Cassette RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E

20

SKVP Super Daiseikai


Technical specifications heat pump
RAS-10SAVP-E RAS-B10SKVP-E kW kW kW W/W 2.50 0.5 to 3.5 0.10 0.49 0.87 5.10 A kWh kW kW kW W/W 245 3.20 0.6 to 6.1 0.12 0.63 1.71 5.08 A RAS-B10SKVP-E m3/h l/s dB(A) dB(A) m3/h l/s dB(A) dB(A) mm kg 546/276 152/77 42/27 57/42 612/282 170/78 43/27 58/42 250 790 208 9 RAS-10SAVP-E m3/h l/s dB(A) dB(A) C dB(A) dB(A) C mm kg 2148 597 46 59 10 to 46 47 60 15 to 24 550 780 290 38 DC twin-rotary RAS-13SAVP-E RAS-B13SKVP-E 3.50 0.6 to 4.5 0.11 0.85 1.37 4.12 A 425 4.20 0.6 to 6.9 0.12 0.95 2.09 4.42 A RAS-B13SKVP-E 564/276 157/77 43/27 58/42 636/300 177/83 44/27 59/42 250 790 208 9 RAS-13SAVP-E 2406 668 48 61 10 to 46 50 63 15 to 24 550 780 290 38 DC twin-rotary RAS-16SAVP-E RAS-B16SKVP-E 4.50 0.8 to 5.0 0.15 1.35 1.82 3.33 A 675 5.50 0.8 to 8.0 0.15 1.49 2.51 3.69 A RAS-B16SKVP-E 606/318 168/88 45/29 60/44 678/342 188/95 45/29 60/45 250 790 208 9 RAS-16SAVP-E 2406 668 49 62 10 to 46 50 63 15 to 24 550 780 290 38 DC twin-rotary

Outdoor unit Indoor unit Cooling capacity Cooling range (min. max.) Power input, cooling (min rated max.) EER Energy efficiency class, cooling Annual energy consumption Heating capacity Heating range (min. max.) Power input, heating (min rated max.) COP Energy efficiency class, heating Indoor unit Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight Outdoor unit Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections Gas Liquid Minimum pipe length Maximum pipe length Maximum height difference Pre-charged pipe length Power supply in in m m m m V-ph-Hz

3/8 1/4 2 25 10 15 220/240-1-50

3/8 1/4 2 25 10 15 220/240-1-50

1/2 1/4 2 25 10 15 220/240-1-50

SKV Suzumi
Outdoor unit Indoor unit Cooling capacity Cooling range (min. max.) Power input, cooling (min. rated max) EER Energy efficiency class, cooling Annual energy consumption Heating capacity Heating range (min. max.) Power input, heating (min. rated max) COP Energy efficiency class, heating Indoor unit Air flow, cooling (h/m/l)) Air flow, cooling (h/m/l)) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/m/l) Air flow, heating (h/m/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight Outdoor unit Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections - dia. gas Flare connections -dia. liquid Minimum pipe length Maximum pipe length Maximum height difference Pre-charged pipe length Power supply in in m m m m V-ph-Hz m3/h l/s dB(A) dB(A) C dB(A) dB(A) C mm kg l/s m3/h dB(A) dB(A) l/s m3/h dB(A) dB(A) mm kg KWh kW kW kW W/W kW kW kW W/W RAS-10SAV-E RAS-10SKV-E 2.5 1.1 3.0 0.255 0.750 0.965 3.33 A 375 3.2 0.9 4.1 0.200 0.860 1.200 3.72 A RAS-10SKV-E/ RAS-M10SKV-E 145/125/95 522/439/331 38/29 51/42 160/140/112 576/495/401 40/30 53/43 250 740 195 8.0 RAS-10SAV-E 1620 450 48 61 15 to 43 50 63 10 to 24 550 660 240 29 DC rotary 3/8 1/4 1 10 8 10 220-240/1/50 RAS-13SAV-E RAS-13SKV-E 3.5 1.1 4.0 0.250 1.070 1.330 3.27 A 535 4.2 0.9 5.0 0.170 1.130 1.480 3.72 A RAS-13SKV-E/ RAS-M13SKV-E 156/132/98 563/481/352 39/26 52/39 175/145/113 630/528/410 40/28 53/41 275 790 205 9.0 RAS-13SAV-E 2100 583 48 61 10 to 46 50 63 15 to 24 550 780 290 35 DC rotary 3/8 1/4 1 20 10 15 220-240/1/50 RAS-16SAV-E RAS-16SKV-E 4.5 0.8 5.0 0.150 1.595 1.900 2.82 C 798 5.3 0.9 6.2 0.150 1.550 1.810 3.42 B RAS-16SKV-E/ RAS-M16SKV-E 192/163/121 691/536/437 45/30 58/43 206/184/151 743/638/549 45/31 58/44 275 790 205 9.0 RAS-16SAV-E 2100 583 49 62 10 to 46 50 63 15 to 24 550 780 290 35 DC twin-rotary 1/2 1/4 1 20 10 15 220-240/1/50

21

Technical specifications heat pump

Indoor models with the letter M in the unit designation are multi-split units; models without the letter M are single-split units.

22

GKHP Fixed-speed high-wall


Technical specifications heat pump

Outdoor unit Indoor unit Cooling capacity Power input, cooling EER Energy efficiency class, cooling Annual energy consumption Running current, cooling Heating capacity Power input, heating COP Energy efficiency class, heating Outdoor unit Air flow Sound pressure level, cooling/heating Sound power level, cooling/heating Dimensions (H x L x D) Weight m3/h l/s dB(A) dB(A) mm kg kWh A kW kW W/W kW kW W/W

RAS-10GAH-ES2 RAS-10GKHP-ES2 2.73 0.84 3.25 A 420 3.76 2.94 0.81 3.63 A RAS-10GAH-ES2 2030 564 47/47 60/60 550 780 290 32

RAS-13GAH-ES2 RAS-13GKHP-ES2 3.78 1.17 3.23 A 585 5.25 4.23 1.16 3.65 A RAS-13GAH-ES2 2120 589 49/49 62/62 550 780 290 40

RAS-18GAH-ES2 RAS-18GKHP-ES2 5.03 1.88 2.68 D 940 8.40 5.50 1.72 3.20 C RAS-18GAH-ES2 1830 508 52/53 65/66 550 780 290 50

RAS-24GAH-ES2 RAS-24GKHP-ES2 6.30 2.47 2.55 E 1235 11.45 6.85 2.44 2.81 D RAS-24GAH-ES2 3380 939 56/57 69/70 715 780 290 65

Technical specifications heat pump


Indoor unit Air flow, cooling (h/l) Air flow, heating (h/l) Sound pressure level (h/l) Sound power level Dimensions (H x L x D) Weight Outdoor unit Operating range, cooling Operating range, heating Flare connections (gas liquid) Maximum pipe length Maximum height difference Pre-charged pipe length Power supply C C in m m m V-ph-Hz m3/h l/s m3/h l/s dB(A) dB(A) mm kg RAS-10GKHP-ES2 540/340 150/95 560/400 155/110 41/31 54/44 250 740 185 8 RAS-10GAH-ES2 15 to 43 10 to 24 3/8 1/4 10 5 10 220/240-1-50 RAS-13GKHP-ES2 630/430 175/120 650/490 180/135 41/31 54/44 275 790 218 10 RAS-13GAH-ES2 15 to 43 10 to 24 1/2 1/4 15 6 15 220/240-1-50 RAS-18GKHP-ES2 900/625 250/174 900/625 250/174 44/35 57/48 298 998 220 13 RAS-18GAH-ES2 15 to 43 10 to 24 1/2 1/4 20 8 15 220/240-1-50 RAS-24GKHP-ES2 900/625 250/174 900/625 250/174 45/37 58/50 298 998 220 13 RAS-24GAH-ES2 15 to 43 10 to 24 1/2 1/4 25 10 15 220/240-1-50

GDV Inverter ducted


Indoor unit Cooling capacity Heating capacity kW kW RAS-M10GDV-E 2.7 4.0 RAS-M13GDV-E 3.7 5.0 RAS-M16GDV-E 4.5 5.5

23

Technical specifications heat pump

RAS-M10GDV-E Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Operating range, cooling Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Operating range, heating Dimensions (H x L x D) Weight Flare connections gas Flare connections liquid External static pressure* (stand/upper limit) * static pressure at nominal condition m3/h l/s dB(A) dB(A) C m3/h l/s dB(A) dB(A) C mm kg in in Pa 720/400 - 200/111 31/23 44/36 21 to 32 720/450 200/111 32/24 45/37 0 to 28 230 750 440 19 3/8 1/4 35.3/54.9

RAS-M13GDV-E 780/428 217/119 32/24 45/37 21 to 32 780/428 217/119 33/25 46/33 0 to 28 230 750 440 19 3/8 1/4 41.2/63.7

RAS-M16GDV-E 780/428 217/119 33/25 46/38 21 to 32 780/428 217/119 34/26 47/34 0 to 28 230 750 440 19 1/2 1/4 41.2/63.7

SM_UV Inverter cassette


Technical specifications heat pump
RAS-M10SMUV-E Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight m3/h (l/s) dB(A) dB(A) m3/h (l/s) dB(A) dB(A) mm kg 588/432 (163/120) 37/30 52/45 588/432 (163/120) 37/30 52/45 268 575 575 15 RAS-M13SMUV-E 618/432 (172/120) 38/30 53/45 618/432 (172/120) 38/30 53/45 268 575 575 15 RAS-M16SMUV-E 660/450 (183/125) 40/31 55/46 660/450 (183/125) 40/31 55/46 268 575 575 15

24

GAV Multi-split outdoor units


Technical specifications heat pump
2-room multi-split 3-room multi-split RAS-M18GAV-E 5.20 1.1 6.2 1.60 3.25 A 6.70 0.7 8.5 1.85 3.62 A 2100 583 48 61 5 to 43 50 63 15 to 24 550 780 290 40 DC twin- rotary RAS-3M26GAV-E 7.50 1.4 8.9 2.25 3.33 A 9.00 0.8 10.8 2.55 3.53 B 3000 833 48 61 10 to 43 48 61 15 to 21 795 900 320 64 DC twin-rotary 4-room multi-split RAS-4M27GAV-E 8.00 1.4 9.2 2.50 3.20 B 9.00 0.8 11.0 2.25 4.00 A 3000 833 48 61 10 to 43 48 61 15 to 21 795 900 320 65 DC twin-rotary

Outdoor unit Cooling capacity Cooling capacity (min. max.) Power input, cooling EER Energy efficiency class, cooling Heating capacity Heating capacity (min. max.) Power input, heating COP Energy efficiency class, heating Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections Gas Liquid Maximum pipe length (per unit/total) Maximum height difference Pre-charged pipe length Power supply in in m m m V-ph-Hz m3/h l/s dB(A) dB(A) C dB(A) dB(A) C mm kg kW kW kW W/W kW kW kW W/W

RAS-M14GAV-E 4.00 1.1 4.5 1.08 3.70 A 4.40 0.5 5.2 1.01 4.35 A 1820 505 46 59 5 to 43 48 61 15 to 24 550 780 290 36 DC twin-rotary

3/8 2 1/4 2 20/30 10 20 220/240-1-50

3/8 2 1/4 2 20/30 10 20 220/240-1-50

3/8 2 + 1/2 1/4 3 25/50 15 50 220/240-1-50

3/8 3 + 1/2 1/4 4 25/70 15 70 220/240-1-50

Toshiba Carrier UK Ltd United Technologies House Guildford Road Leatherhead Surrey KT22 9UT Tel: 01372 220 240. Fax: 01372 220241. [email protected] www.toshiba-aircon.co.uk TCUK/RES-05.2008 The manufacturer reserves the right to change the product specifications, data and images without notice.