Residential
Residential
Residential
Index
Inverter technology Indoor air quality Design and control Matching tables Super Daiseikai Suzumi GKHP Fixed speed indoor units Multi-split systems GDV/SM_UV Multi-split indoor units GAV Multi-split outdoor units Combination ratings Technical tables
4 6 8 10 11 12 13 14 15 16 17 20
Residential
that constantly monitors functions and components and makes maintenance very easy. possible to have comfort combined with energy savings (up to 25% compared to standard operation). desired temperature is quickly reached.
Eco-logic: with this function, it is Hi-Power: with extra air flow the
operate at ultra low fan speed, reaching extraordinary low noise levels.
Super Daiseikai
Suzumi
10
Residential range - single-split systems
OUTDOOR UNIT:
sizes
Inverter
10
13
16
18
24
RAS-10SAVP-E RAS-B10SKVP-E
RAS-13SAVP-E RAS-B13SKVP-E
RAS-16SAVP-E RAS-B16SKVP-E
RAS-10SAV-E RAS-10SKV-E
RAS-13SAV-E RAS-13SKV-E
RAS-16SAV-E RAS-16SKV-E
Fixed-speed
RAS-10GAH-ES2 RAS-10GKHP-ES2
RAS-13GAH-ES2 RAS-13GKHP-ES2
RAS-18GAH-ES2 RAS-18GKHP-ES2
RAS-24GAH-ES2 RAS-24GKHP-ES2
2 rooms
OUTDOOR UNIT: RAS-M14GAV-E RAS-M18GAV-E
3 rooms
RAS-3M26GAV-E
4 rooms
RAS-4M27GAV-E
sizes 10 & 13
SKVP
sizes 10 & 13
SKV
sizes 10 & 13
GDV
SM_UT
SKVP
AG+ PLASMA AIR PURIFIER SINGLE/MULTI-SPLIT DC HYBRID INVERTER
11
... and design! With its compact dimensions and its modern design, the Super Daiseikai is very discreet and unobtrusive. Its exclusive silver sides give it an additional touch of elegance.
12
SKV
PURE INDOOR AIR WITH 7 IN 1 FILTRATION SYSTEM SINGLE/MULTI-SPLIT A/A CLASS DC ROTARY INVERTER
Purity without compromise! Toshibas 7-in-1 filtration system helps stop impurities from reaching you and your family. With this advanced system, the air passes through several filters and becomes purer, fresher and healthier, ensuring optimised comfort in your home.
13
dB(A) dB(A) mm
14
For premises that require air conditioning in more than one room, the Toshiba multi-split system is the ideal solution. One outdoor unit is capable of operating two, three or four indoor units. They are compact and elegant and designed to blend in with any room interior. Toshiba offers a wide range of possibilities to create all the comfort you desire. The full range of indoor units can satisfy every kind of need: it includes unobtrusive ducted units and modern high walls, that provide high-tech, sophisticated design and complete air filtration at the same time. The efficient inverter systems are composed of high quality components: control electronics, motor, compressor. Toshiba solutions are universally recognised by air conditioning professionals for their total reliability.
15
STYLISH DESIGN AND COMPACT DIMENSIONS, TO SUIT ALL STANDARD GRIDS MULTI-SPLIT EASY MAINTENANCE
16
2 Rooms
M-SKV
3 Rooms
4 Rooms
17
Combination ratings heat pump
Cooling, 230 V Size 14 14 Heating, 230 V Size 14 14 Operating status 1 unit operation 2 unit operation Operating status 1 unit operation 2 unit operation Unit A 10 13 10 13 Combination Unit C Unit B 10 10 Unit D Unit A 2.50 3.50 1.95 2.33 Unit capacity (kW) Unit C Unit B 1.95 1.67 Unit D Cooling capacity (kW) Min. Rated Max. 1.1 2.5 3.2 1.1 3.5 3.8 1.4 3.5 4.4 1.4 4.0 4.5 Heating capacity (kW) Min. Rated Max. 0.7 3.2 4.0 0.7 4.2 4.4 0.9 4.3 4.6 0.9 4.4 4.7 Power input (W) Rated 570 1100 1070 1080 Power input (W) Rated 850 1250 980 1010
Combination Unit C Unit D Unit A Unit B 10 13 10 10 13 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E
Unit capacity (kW) Unit C Unit D Unit A Unit B 3.20 4.20 2.15 2.15 2.50 1.90 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E
18
1 unit operation
2 unit operation
Unit D -
Unit D -
Cooling capacity (kW) Min. Rated Max. 1.1 2.7 3.2 1.1 3.7 4.2 1.1 4.5 4.9 1.4 5.1 6.1 1.4 5.2 6.2 1.4 5.2 6.2 1.4 5.2 6.2 Cooling capacity (kW) Min. Rated Max. 0.7 4.0 5.2 0.7 5.0 6.5 0.7 5.5 6.9 0.9 6.4 8.3 0.9 6.7 8.7 0.9 6.7 8.7 0.9 6.7 8.7 Cassette RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E
Power input (W) Rated 600 1100 1500 1550 1600 1600 1600 Power input (W) Rated 1200 1800 1900 1800 1850 1850 1850
Operating status
18
1 unit operation
18
2 unit operation
Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 13 13 16 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E
Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.20 3.20 3.72 2.98 3.35 3.35 3.88 2.82 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E
18
26
1 unit operation
26
2 unit operation
26
3 unit operation
Operating status
26
1 unit operation
26
2 unit operation
26
3 unit operation
Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 16 10 13 13 16 13 16 16 10 10 10 13 10 10 16 10 10 13 13 10 16 13 10 13 13 13 16 16 10 16 13 13 16 16 13 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E
Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.60 3.60 4.22 3.38 4.57 3.33 3.95 3.95 4.35 3.95 4.30 4.30 2.87 2.87 2.87 3.35 2.68 2.68 3.59 2.61 2.61 3.14 3.14 2.51 3.34 3.03 2.43 2.93 2.93 2.93 3.26 3.26 2.37 3.16 2.87 2.87 3.09 3.09 2.81 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E
19
27
1 unit operation
27
2 unit operation
27
3 unit operation
27
4 unit operation
Operating status
27
1 unit operation
27
2 unit operation
27
3 unit operation
27
4 unit operation
Combination Unit C Unit D Unit A Unit B 10 13 16 10 10 13 10 16 10 13 13 16 13 16 16 10 10 10 13 10 10 16 10 10 13 13 10 16 13 10 13 13 13 16 16 10 16 13 13 16 16 13 16 16 16 10 10 10 10 13 10 10 10 16 10 10 10 13 13 10 10 16 13 10 10 13 13 13 10 16 13 13 10 13 13 13 13 16 16 10 10 Indoor unit: Super Daiseikai RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E
Unit capacity (kW) Unit C Unit D Unit A Unit B 4.00 5.00 5.50 3.60 3.60 4.22 3.38 4.57 3.33 3.95 3.95 4.35 3.95 4.30 4.30 2.87 2.87 2.87 3.35 2.68 2.68 3.54 2.58 2.58 3.11 3.11 2.49 3.34 3.03 2.43 2.93 2.93 2.93 3.26 2.26 2.37 3.16 2.87 2.87 3.06 3.06 2.78 3.00 3.00 3.00 2.23 2.23 2.23 2.23 2.62 2.09 2.09 2.09 2.83 2.06 2.06 2.06 2.50 2.50 2.00 2.00 2.68 2.43 1.95 1.95 2.37 2.37 2.37 1.89 2.54 2.31 2.31 1.85 2.25 2.25 2.25 2.25 2.61 2.61 1.89 1.89 SKV Inverter Ducted Inverter RAS-M10SKV-E, RAS-M10GDV-E RAS-M13SKV-E, RAS-M13GDV-E RAS-M16SKV-E, RAS-M16GDV-E
Cooling capacity (kW) Min. Rated Max. 0.8 4.0 5.2 0.8 5.0 6.5 0.8 5.5 6.9 1.5 7.2 10.0 1.5 7.6 10.1 1.5 7.9 10.1 1.5 7.9 10.1 1.5 8.3 10.2 1.5 8.6 10.2 2.0 8.6 10.4 2.0 8.7 10.5 2.0 8.7 10.5 2.0 8.7 10.5 2.0 8.8 10.6 2.0 8.8 10.6 2.0 8.9 10.7 2.0 8.9 10.7 2.0 8.9 10.7 2.2 9.0 10.8 2.2 8.9 10.8 2.2 8.9 10.9 2.2 9.0 10.9 2.2 9.0 10.9 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 2.2 9.0 11.0 Cassette RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E
20
Outdoor unit Indoor unit Cooling capacity Cooling range (min. max.) Power input, cooling (min rated max.) EER Energy efficiency class, cooling Annual energy consumption Heating capacity Heating range (min. max.) Power input, heating (min rated max.) COP Energy efficiency class, heating Indoor unit Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight Outdoor unit Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections Gas Liquid Minimum pipe length Maximum pipe length Maximum height difference Pre-charged pipe length Power supply in in m m m m V-ph-Hz
SKV Suzumi
Outdoor unit Indoor unit Cooling capacity Cooling range (min. max.) Power input, cooling (min. rated max) EER Energy efficiency class, cooling Annual energy consumption Heating capacity Heating range (min. max.) Power input, heating (min. rated max) COP Energy efficiency class, heating Indoor unit Air flow, cooling (h/m/l)) Air flow, cooling (h/m/l)) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Air flow, heating (h/m/l) Air flow, heating (h/m/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Dimensions (H x L x D) Weight Outdoor unit Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections - dia. gas Flare connections -dia. liquid Minimum pipe length Maximum pipe length Maximum height difference Pre-charged pipe length Power supply in in m m m m V-ph-Hz m3/h l/s dB(A) dB(A) C dB(A) dB(A) C mm kg l/s m3/h dB(A) dB(A) l/s m3/h dB(A) dB(A) mm kg KWh kW kW kW W/W kW kW kW W/W RAS-10SAV-E RAS-10SKV-E 2.5 1.1 3.0 0.255 0.750 0.965 3.33 A 375 3.2 0.9 4.1 0.200 0.860 1.200 3.72 A RAS-10SKV-E/ RAS-M10SKV-E 145/125/95 522/439/331 38/29 51/42 160/140/112 576/495/401 40/30 53/43 250 740 195 8.0 RAS-10SAV-E 1620 450 48 61 15 to 43 50 63 10 to 24 550 660 240 29 DC rotary 3/8 1/4 1 10 8 10 220-240/1/50 RAS-13SAV-E RAS-13SKV-E 3.5 1.1 4.0 0.250 1.070 1.330 3.27 A 535 4.2 0.9 5.0 0.170 1.130 1.480 3.72 A RAS-13SKV-E/ RAS-M13SKV-E 156/132/98 563/481/352 39/26 52/39 175/145/113 630/528/410 40/28 53/41 275 790 205 9.0 RAS-13SAV-E 2100 583 48 61 10 to 46 50 63 15 to 24 550 780 290 35 DC rotary 3/8 1/4 1 20 10 15 220-240/1/50 RAS-16SAV-E RAS-16SKV-E 4.5 0.8 5.0 0.150 1.595 1.900 2.82 C 798 5.3 0.9 6.2 0.150 1.550 1.810 3.42 B RAS-16SKV-E/ RAS-M16SKV-E 192/163/121 691/536/437 45/30 58/43 206/184/151 743/638/549 45/31 58/44 275 790 205 9.0 RAS-16SAV-E 2100 583 49 62 10 to 46 50 63 15 to 24 550 780 290 35 DC twin-rotary 1/2 1/4 1 20 10 15 220-240/1/50
21
Indoor models with the letter M in the unit designation are multi-split units; models without the letter M are single-split units.
22
Outdoor unit Indoor unit Cooling capacity Power input, cooling EER Energy efficiency class, cooling Annual energy consumption Running current, cooling Heating capacity Power input, heating COP Energy efficiency class, heating Outdoor unit Air flow Sound pressure level, cooling/heating Sound power level, cooling/heating Dimensions (H x L x D) Weight m3/h l/s dB(A) dB(A) mm kg kWh A kW kW W/W kW kW W/W
RAS-10GAH-ES2 RAS-10GKHP-ES2 2.73 0.84 3.25 A 420 3.76 2.94 0.81 3.63 A RAS-10GAH-ES2 2030 564 47/47 60/60 550 780 290 32
RAS-13GAH-ES2 RAS-13GKHP-ES2 3.78 1.17 3.23 A 585 5.25 4.23 1.16 3.65 A RAS-13GAH-ES2 2120 589 49/49 62/62 550 780 290 40
RAS-18GAH-ES2 RAS-18GKHP-ES2 5.03 1.88 2.68 D 940 8.40 5.50 1.72 3.20 C RAS-18GAH-ES2 1830 508 52/53 65/66 550 780 290 50
RAS-24GAH-ES2 RAS-24GKHP-ES2 6.30 2.47 2.55 E 1235 11.45 6.85 2.44 2.81 D RAS-24GAH-ES2 3380 939 56/57 69/70 715 780 290 65
23
RAS-M10GDV-E Air flow, cooling (h/l) Sound pressure level, cooling (h/l) Sound power level, cooling (h/l) Operating range, cooling Air flow, heating (h/l) Sound pressure level, heating (h/l) Sound power level, heating (h/l) Operating range, heating Dimensions (H x L x D) Weight Flare connections gas Flare connections liquid External static pressure* (stand/upper limit) * static pressure at nominal condition m3/h l/s dB(A) dB(A) C m3/h l/s dB(A) dB(A) C mm kg in in Pa 720/400 - 200/111 31/23 44/36 21 to 32 720/450 200/111 32/24 45/37 0 to 28 230 750 440 19 3/8 1/4 35.3/54.9
RAS-M13GDV-E 780/428 217/119 32/24 45/37 21 to 32 780/428 217/119 33/25 46/33 0 to 28 230 750 440 19 3/8 1/4 41.2/63.7
RAS-M16GDV-E 780/428 217/119 33/25 46/38 21 to 32 780/428 217/119 34/26 47/34 0 to 28 230 750 440 19 1/2 1/4 41.2/63.7
24
Outdoor unit Cooling capacity Cooling capacity (min. max.) Power input, cooling EER Energy efficiency class, cooling Heating capacity Heating capacity (min. max.) Power input, heating COP Energy efficiency class, heating Air flow Sound pressure level, cooling Sound power level, cooling Operating range, cooling Sound pressure level, heating Sound power level, heating Operating range, heating Dimensions (H x L x D) Weight Compressor type Flare connections Gas Liquid Maximum pipe length (per unit/total) Maximum height difference Pre-charged pipe length Power supply in in m m m V-ph-Hz m3/h l/s dB(A) dB(A) C dB(A) dB(A) C mm kg kW kW kW W/W kW kW kW W/W
RAS-M14GAV-E 4.00 1.1 4.5 1.08 3.70 A 4.40 0.5 5.2 1.01 4.35 A 1820 505 46 59 5 to 43 48 61 15 to 24 550 780 290 36 DC twin-rotary
Toshiba Carrier UK Ltd United Technologies House Guildford Road Leatherhead Surrey KT22 9UT Tel: 01372 220 240. Fax: 01372 220241. [email protected] www.toshiba-aircon.co.uk TCUK/RES-05.2008 The manufacturer reserves the right to change the product specifications, data and images without notice.