Features
Choice of various viewing angles Available on tape and reel. Reliable and robust Pb free The product itself will remain within RoHS compliant version.

Description
The series is specially designed for applications requiring higher brightness The led lamps are available with different colors, intensities..

Applications
TV set Monitor Telephone Computer

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

Device Selection Guide


Chip Materials
AlGaInP

Emitted Color
Brilliant Yellow Green

Resin Color
Green Diffused

Absolute Maximum Ratings (Ta=25)


Parameter
Continuous Forward Current Peak Forward Current (Duty 1/10 @ 1KHZ) Reverse Voltage Power Dissipation Operating Temperature Storage Temperature Soldering Temperature

Symbol
IF IFP VR Pd Topr Tstg Tsol

Rating
25 60 5 60 -40 ~ +85 -40 ~ +100 260

Unit
mA mA V mW

for 5 sec.

Electro-Optical Characteristics (Ta=25)


Parameter
Luminous Intensity Viewing Angle Peak Wavelength Dominant Wavelength Spectrum Radiation Bandwidth Forward Voltage Reverse Current

Symbol
Iv 21/2 p d VF IR

Min.
40 ----------------1.7 -----

Typ.
80 30 575 573 20 2.0 -----

Max.
--------------------2.4 10

Unit
mcd deg nm nm nm V A

Condition
IF=20mA IF=20mA IF=20mA IF=20mA IF=20mA IF=20mA VR=5V

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

Typical Electro-Optical Characteristics Curves


Relative Intensity vs. Wavelength (Ta=25

Directivity (Ta=25

Relative Intensity (a.u.)

Wavelength (nm) Forward Current vs. Forward Voltage (Ta=25

Radiation Angle

Relative Intensity (a.u.)

Relative Intensity vs. Forward Current (Ta=25


1.5

Relative Intensity(a.u.)

Forward Current (mA)

1.0

0.5

0.0

10

15

20

25

Forward Voltage (V) Relative Intensity vs. Ambient Temp.


2.0

Forward Current (mA) Forward Current vs. Ambient Temp.


40

Relative Intensity(a.u.)

1.5

Forward Current (mA)

30

20

1.0

10

0.5

0.0 25

20

40

60

80

100

30

35

40

45

50

55

60

65

70

Ambient Temperature Ta()

Ambient Temperature Ta()

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

Package Dimension

Note: Note: 1. All dimensions are in millimeters 2. The height of flange must be less than 1.5mm(0.059"). 3. Without special declared, the tolerance is 0.25mm.

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

Moisture Resistant Packing Materials


Label Explanation

Pb

EVERLIGHT
RoHS

333-2SYGD/S530-E2

CPN: Customer's Production Number P/N : Production Number QTY: Packing Quantity CAT: Ranks HUE: Dominant Wavelength REF: Reference LOT No: Lot Number

Packing Specification Anti-electrostatic bag Inner Carton Outside Carton

Pb
EL ECTR OSTATIC ELECTR ONAGNET IC MAGNETIC OR RADIOACTIVE RELDS

anti-static for 750

Packing Quantity
1. 500 PCS/1 Bag, 5 Bags/1 Inner Carton 2. 10 Inner Cartons/1 Outside Carton

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

Notes
1. Lead Forming During lead formation, the leads should be bent at a point at least 3mm from the base of the epoxy bulb. Lead forming should be done before soldering. Avoid stressing the LED package during leads forming. The stress to the base may damage the LEDs characteristics or it may break the LEDs. Cut the LED lead frames at room temperature. Cutting the lead frames at high temperatures may cause failure of the LEDs. When mounting the LEDs onto a PCB, the PCB holes must be aligned exactly with the lead position of the LED. If the LEDs are mounted with stress at the leads, it causes deterioration of the epoxy resin and this will degrade the LEDs. 2. Storage The LEDs should be stored at 30 C or less and 70%RH or less after being shipped from Everlight and the storage life limits are 3 months. If the LEDs are stored for 3 months or more, they can be stored for a year in a sealed container with a nitrogen atmosphere and moisture absorbent material. Please avoid rapid transitions in ambient temperature, especially, in high humidity environments where condensation can occur. 3. Soldering Careful attention should be paid during soldering. When soldering, leave more then 3mm from solder joint to epoxy bulb, and soldering beyond the base of the tie bar is recommended. Recommended soldering conditions: Hand Soldering 300 Max. (30W Max.) Temp. at tip of iron Soldering time 3 sec Max. Distance 3mm Min.(From solder joint to epoxy bulb) Recommended soldering profile

Preheat temp. Bath temp. & time Distance

DIP Soldering 100 Max. (60 sec Max.) 260 Max., 5 sec Max 3mm Min. (From solder joint to epoxy bulb)

laminar wave

Fluxing

Prehead

Avoiding applying any stress to the lead frame while the LEDs are at high temperature particularly when soldering. Dip and hand soldering should not be done more than one time After soldering the LEDs, the epoxy bulb should be protected from mechanical shock or vibration until the LEDs return to room temperature. A rapid-rate process is not recommended for cooling the LEDs down from the peak temperature. Although the recommended soldering conditions are specified in the above table, dip or hand soldering at the lowest

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

DATASHEET LAMP 333-2SYGD/S530-E2

possible temperature is desirable for the LEDs. Wave soldering parameter must be set and maintain according to recommended temperature and dwell time in the solder wave. 4. Cleaning When necessary, cleaning should occur only with isopropyl alcohol at room temperature for a duration of no more than one minute. Dry at room temperature before use. Do not clean the LEDs by the ultrasonic. When it is absolutely necessary, the influence of ultrasonic cleaning on the LEDs depends on factors such as ultrasonic power and the assembled condition. Ultrasonic cleaning shall be pre-qualified to ensure this will not cause damage to the LED 5. Heat Management Heat management of LEDs must be taken into consideration during the design stage of LED application. The current should be de-rated appropriately by referring to the de-rating curve found in each product specification. The temperature surrounding the LED in the application should be controlled. Please refer to the data sheet de-rating curve.

6. ESD (Electrostatic Discharge) The products are sensitive to static electricity or surge voltage. ESD can damage a die and its reliability. When handling the products, the following measures against electrostatic discharge are strongly recommended: Eliminating the charge Grounded wrist strap, ESD footwear, clothes, and floors Grounded workstation equipment and tools ESD table/shelf mat made of conductive materials Proper grounding is required for all devices, equipment, and machinery used in product assembly. Surge protection should be considered when designing of commercial products. If tools or equipment contain insulating materials such as glass or plastic, the following measures against electrostatic discharge are strongly recommended: Dissipating static charge with conductive materials Preventing charge generation with moisture Neutralizing the charge with ionizers
7. Other Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please dont reproduce or cause anyone to reproduce them without EVERLIGHTs consent.

Copyright 2010, Everlight All Rights Reserved. Release Date : Sep .05 .2012. Issue No: DLE-0006112 _Rev.3

www.everlight.com

You might also like