Imaging Spectrometers: Jobin Yvon
Imaging Spectrometers: Jobin Yvon
Imaging Spectrometers: Jobin Yvon
Imaging Spectrometers
iHR Series
Uniquely shaped for uniquely superior performance.
No Re-diffracted Light
Re-diffracted light is light that enters the spectrometer and hits the grating twice due to an alignment of some rays of diffracted light with one of the mirrors and the grating. This light diffracts off the grating a second time and shows as a dim background illumination on the output image. In spectroscopy, this light manifests as an elevated baseline and reduced sensitivity. This set of conditions happens across different wavelength regions and is more likely to occur in conventional symmetric Czerny-Turner spectrometers. Computer optimization of the asymmetric optical path eliminates re-diffracted light through precise placement of optical component locations. The unique shape of the iHR series is a result of all these stringent design requirements.
All design factors were optimized to produce the most reliable optical platform and set new industry standards never achieved before in this class of imaging spectrometers.
Manufacturing Excellence
The iHR series is built with the highest quality materials and structure. The instrument starts as a single casting and is machined until it acquires its unique shape. This eliminates possibilities of light leaks and provides the strongest possible housing for the instrument. The electronics are installed in a light compartment separate from the light tight optical cavity, under the spectrometer. After construction, the iHR goes through a series of rigorous burn-in and testing cycles. The drive mechanism is checked and rechecked to ensure that the system meets our repeatability and accuracy requirements.
Kinemetic Up to 4 ports (2 entrance and turret with easy access hatch 2 exit)
Purge port for UV and NIR Easy CCD focus and alignment with external locking mechanism
iHR550
320 mm f/4.1 Focal Length Aperture Spectral Range Grating Size Number of Gratings on Turret Flat Field Size Resolution with Exit Slit and PMT Wavelength Accuracy Repeatability Spectral Dispersion (@500 nm) Magnification Stray Light* Scan Speed Step Size Computer Interface Length Width Dimensions Height Optical Axis 98 mm (3.9 in) 20 kg (45 lb)
(Height from bottom of instrument)
550 mm f/6.4 150 to 1500 nm w/1200 g/mm grating 150 nm to 40m w/appropriate gratings 76 mm x 76 mm up to 3 30 mm x 12 mm 0.025 nm 0.20 nm 0.075 nm 1.34 nm/mm 1.1 1 x 10-5 160 nm/sec 0.002 nm Hi-Speed USB 648 mm (25.51 in) 460 mm (18.09 in) 193 mm (7.78 in) 98 mm (3.9 in) 28 kg (62 lb)
150 to 1500 nm w/1200 g/mm grating 150 nm to 40 m w/appropriate gratings 68 mm x 68 mm up to 3 30 mm x 12 mm 0.06 nm 0.20 nm 0.075 nm 2.31 nm/mm 1.1 1.5 x 10-4 160 nm/sec 0.002 nm Hi-Speed USB 417 mm (16.4 in) 422 mm (16.6 in) 192 mm (7.6 in)
Nominal Weight
Nominal Weight
*Stray measured at 1 nm from 514 nm laser with HORIBA Jobin Yvon Holographic Gratings. All specifications given for 1200 g/mm grating at 435 nm and are subject to change without notice.
Single Typical Pixel Spectral Spectral Resolution (nm) Coverage (nm) 0.01 0.04 0.06 0.09 0.13 0.20 0.41 0.83 0.005 0.023 0.036 0.060 0.083 0.128 0.263 0.531
Typical Spectral Resolution (nm) 0.02 0.07 0.11 0.18 0.25 0.39 0.79 1.59
iHR550
CCDs with 13.5 m pixels Grating (g/mm) Dispersion (nm/mm) Spectrometer Mechanical Range* (nm) Spectral Coverage (nm) with 26.7 mm CCD Single Pixel Spectral Coverage (nm) 0.002 0.007 0.011 0.018 0.025 0.038 0.078 0.156 CCDs with 26 m pixels
Typical Single Spectral Pixel Spectral Resolution (nm) Coverage (nm) 0.01 0.02 0.03 0.05 0.07 0.11 0.23 0.47 0.004 0.014 0.021 0.035 0.048 0.074 0.150 0.301
Typical Spectral Resolution (nm) 0.01 0.04 0.06 0.10 0.14 0.22 0.45 0.90
4 14 22 36 49 76 154 309
* The systems optical range will depend not only on the grating groove density, but also the grating blaze angle and the detectors spectral response. ** Dispersion, Spectral Coverage and Resolution values are given for 500 nm. These values may vary at different wavelengths.
Fluorescence
With HORIBA Jobin Yvon spectroscopy components, you can design a custom fluorometer using iHR spectrometers as the excitation and emission spectrometers with a choice of excitation sources, sample compartments and detectors from our full line of products and accessories. Complete system control is available through our SynerJY software. HORIBA Jobin Yvons specialized Fluorescence Division offers a full line of dedicated, fully characterized spectrofluorometers and both timedomain and frequencydomain fluorescence lifetime instruments, featuring the worlds most sensitive instruments for research and analytical environments.
Photoluminescence (PL)
Photoluminescence is a simple yet powerful technique for characterizing semiconductor materials. An iHR550 equipped with a cooled CCD detector for the range of 400-1000 nm, and a cooled InGaAs detector for the 800-1600 nm range, is an excellent general purpose photoluminescence measurement system. Separate optical configurations can be designed for room temperature PL and low-temperature PL using the same iHR spectrometer. iHR spectrometers provide the flexibility to change experiments and optical configurations to meet your needs.
HORIBA Jobin Yvons Sales and Applications staff can provide expert advice on configuring a system for your specific experiment.
Ordering Information
iHR320 iHR550 MAI-IR MAI-II MAI-I5I MAI-ICM iHR320 Base Unit iHR550 Base Unit iHR Series Resolution Array Adapter for HORIBA Jobin Yvons CCDs iHR320 Imaging Array Adapter for HORIBA Jobin Yvon CCDs iHR550 Imaging Array Adapter for HORIBA Jobin Yvon CCDs iHR Array Adapter for C-Mount Detectors
iHR Accessories
AFW-IHR AFW-C6PM MHR-FSA ACH-C iHR320 Internal Filter Wheel, 6 x 25.4 mm (1 inch) filter positions External Filter Wheel, 6 x 25.4 mm (1 inch) filter positions Filter Slide, 3 x 25.4 mm (1 inch) filter positions Optical Chopper for use with IR detectors and Lock-In Amplifiers XY adjustable Fiber Optic Adapter for 10 mm and 14 inch ferrules Direct Fiber mount, 14 inch ferrule Direct Fiber mount, 10 mm ferrule 1x Imaging Fiber Adapter SampleMax Sample Compartment SampleMax Sample Compartment optimized for UV
iHR320 Computer Controlled Slits MSL-I3FN2 (-I3FX2) Front Entrance (Exit) Slit: 0 to 2 mm in 2 m steps MSL-I3SN2 (-I3SX2) Side Entrance (Exit) Slit: 0 to 2 mm in 2 m steps MSL-I3FN7 (-I3FX7) Front Entrance (Exit) Slit: 0 to 7 mm in 6.25 m steps MSL-I3SN7 (-I3SX7) iSide Entrance (Exit) Slit: 0 to 7 mm in 6.25 m steps iHR550 Computer Controlled Slits MSL-I5FN2 (-I5FX2) Front Entrance (Exit) Slit: 0 to 2 mm in 2 m steps MSL-I5SN2 (-I5SX2) Side Entrance (Exit) Slit: 0 to 2 mm in 2 m steps MSL-I5FN7 (-I5FX7 Front Entrance (Exit) Slit: 0 to 7 mm in 6.25 m steps MSL-I5SN7 (-I5SX7) Side Entrance (Exit) Slit: 0 to 7 mm in 6.25 m steps MSL-IANM MSL-IAXM MGM-IT MGM-I5T MSH-ICF MSH-ICS Motorized Swing Entrance Mirror Motorized Swing Exit Mirror Additional Interchangeable Triple Grating Turret for iHR320 Additional Interchangeable Triple Grating Turret for iHR550 Internal CCD Shutter for an iHR Front Entrance Port Internal CCD Shutter for an iHR Side Entrance Port
DPM-HV
UV-VIS Photomultiplier Tube (PMT) and Housing DSS Detectors Solid State Detectors including Si, Ge, InGaAs, InAs, PBs, PbSe & MCT 1427B Solid State Detector Interface
UVCOAT-MIR UV coating of spectrometer mirrors for increased throughput between 200 nm 300 nm AUCOAT-MIR Gold coating of spectrometer mirrors for increased throughput in the NIR and IR. Cuts out wavelengths below 500 nm
HORIBA Jobin Yvon was the first spectroscopy based company to embrace the emerging CCD detector technology and to integrate the unique two dimensional capabilities of these detectors with spectrometer control functions.