DET NORSKE VERITAS


TYPE APPROVAL CERTIFICATE
CERTIFICATE NO. S-6654 This is to certify that the Gangway with type designation(s) 42,5 m Telesopic Gangway Manufactured by

Marine Aluminium A/S


Haugesund, Norway
is found to comply with ISO 5488 Shipbuilding - Accommodation ladders ISO 7061:1993(E) - Shipbuilding - Aluminium shore gangways for seagoing vessels Standard for Certification No. 2.22 Lifting Appliances

Application Gangway for offshore use between vessel and offshore installation/mobil platform

Hvik, 2013-05-14 for Det Norske Veritas AS

This Certificate is valid until 2017-06-30

Aldo Matteucci Head of Section

DNV local office: Stord

Ole-Henrik Andressen Surveyor

This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 1 of 3

Certificate No.: S-6654 File No.: 686.36 Job Id.: 262.1-011953-1

Product description
42,5 m telescopic Aluminium Gangway Mean length Minimum length before emergency lift off Maximum length before emergency lift off Maximum length with maximum live load Maximum wind speed during lift off Maximum wind in parekd position Maximum opperational design load Pipes with water uppercord Flexible pipe on the telescopic part of the gangway. Acess platform on the end Pipe connected at the end, concentrated load 36,5m 30,5 m-31,0 m 42,0 m-42,5 m 41,0 m 36 m/s 55 m/s 4,0 kN/m2 live load, sum 188,1 kN 2 0,34 kN/m 3,51kN 1 kN 2,0 kN

Application/Limitation
The structure calculaton is done according to DNVs Standard for Certification 2.22 Lifting Appliances, Oct. 2011 The hydraulic cylinders are understood to be used only to lift and lower the gangway without load, and is assumed delivered with manufacturers certificate. If a DNV product certificate is required, all materials shall be delivered with material certificates equal to minimum EN10204:2005 3.1. If a DNV product certificate is required, all welding to be carried out by qualified welders. Reference is given to DNVs Standard for Certification 2.22 Lifting Appliances, Oct. 2011. If a DNV product certificate is required, the gangway is subject to testing according to ISO7061:1993(E) 8.3.2. Connection and support to the ships structure is assumed covered by separate approval. The gangway is assumed to be function and load tested after installation onboard.

Type Approval documentation


Drawing no. 1140371-002 1140371-100 1140371-101 1140371-101-1 1140371-102 1140371-103 1140371-105 1140371-124 1140371-200 1140371-260 1140371-261 1140371-262 1140371-262-01 1140371-262-02 1140371-264 1140371-264-01 1140371-264-02 1140371-266 Rev. 02 01 04 01 02 02 02 01 01 01 01 01 01 01 Title Structural design report for aluminium gangway and steel tower Telescopic Gangway - General Arrangement Telescopic Gangway - Fixed Part Telescopic Gangway - Fixed Part Details Telescopic Gangway - Outer part Inner End Telescope - Support Details Fixed Part Inner End Telescope - Support Details Telescopic Gangway Lifting Arrangement Telescopic Gangway Steel Tower - General Arrangement Telescopic Gangway Foundation Main Drawing Telescopic Gangway Foundation Beams Telescopic Gangway Foundation Vertical Plates Prefab Sketch Prefab Sketch Telescopic Gangway Foundation, Foundation Plan Prefab Sketch Prefab Sketch Telescopic Gangway Foundation Section B & C Status For Information For Information Type Approved Type Approved Type Approved Type Approved Type Approved Type Approved For Information Type Approved Type Approved Type Approved Type Approved Type Approved For Information Type Approved Type Approved Type Approved

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 2 of 3

Certificate No.: S-6654 File No.: 686.36 Job Id.: 262.1-011953-1

Tests carried out


Typetesting not relevant. Before taken into use testing according to DNV Standard for Certification 2.22. the load shall be spread uniformely ref ISO 7061 8.3.3.

Marking of product
The gangway shall be marked as follows: - Manufacturer's name - Safe Working Load, SWL - Product certificate number - Reference to Type Approval number.

Marking of product
For retention of the Type Approval, a DNV Surveyor shall perform a survey every second year and before the expire date of the certificate to verify that the condition for the approval are complied with.

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 3 of 3