ASCE7 05 Wind
ASCE7 05 Wind
ASCE7 05 Wind
JOB REF:
Building
D2010
REVISION:
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
roof
6.5.12. Design Wind Loads on Enclosed and Partially Enclosed Buildings. (all Heights)
= 45.14
= 12
= (0.613 v) Kz Kzt Kd I
= 45
m/sec
leeward
No.
qz
windward
= 100.6621 mph
local Gr. Level
Terrain category:
Exposure B
Exposure C
Kd
= 0.85
Exposure D
Kd
Directionality factor
211774985.xls.ms_office
PROJECT:
JOB REF:
Building
D2010
REVISION:
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
*Cogeneration power plants that do not supply power on the national grid shall be designated Occupancy Category II.
Occupancy Category:
III
Region
I
= 1.15
Importance factor
b0.45
zmin*
365.76
a114.0
7.0
b^
0.84
a^
117.0
0.30
97.54
113
9.14
9.5
274.32
119.5
1.00
116.5
0.65
0.20
152.40
115
4.57
11.5
213.36
1111.5
1.07
119.0
0.80
0.15
198.12
118
2.13
zg
*zmin = minimum height used to ensure that the equivalent height z is greater of 0.6h or z min.
For buildings with h 5 zmin, z shall be taken as zmin
a
zg
= 7.0
= 365.76
Kz
= 2.01(z/zg)2/a
= 2.01(4.572/zg)2/a
Kz min
m
(ASCE 7-05, 6.5.6.6, Table [6-3])
Local ground
H/2
Lh
Hill shape
H
Lh
= 0
= 13000
H/Lh
= 0.00
= 500
K1/(H/Lh) = 0.75
211774985.xls.ms_office
Direction
m
Height of Hill
Distance upwind of crest to where the difference in ground elevation is half the height of hill
PROJECT:
K1
Lh
= 0.00
= 13000
m
K2
= 1.50
= 0.97
1 - x/mLh
g
K3
= 2.50
= 0.99
e-gz/Lh
Kzt
= 1.00
[1+K1K2K3]2
= 0.85
JOB REF:
Building
D2010
REVISION:
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
Topographic factor
Enclosure classification
GCpi
Cp
Cp
= 0.18
= 0.80
Windward wall
= -0.50
= -0.70
Leeward wall
Cp
Side wall
Cp
= variable as shown
Roof
-0.70
0.80
Plan
-0.90
-0.50
-0.30
-0.50
0.80
Elevation
-0.50
-0.70
= qGCp-qi(GCpi)
= qz
qi
= qh
= qh
211774985.xls.ms_office
PROJECT:
JOB REF:
Building
WIND LOADS ACTING ON STRUCTURE
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
211774985.xls.ms_office
PART OF STRUCTURE:
DESIGN CODE
D2010
REVISION:
Kzt
Kz
qz
45
0.85
1.15
0.57472
697.3621
4.88
45
0.85
1.15
0.585525 710.4736
8.54
45
0.85
1.15
0.687045 833.6569
12.2
45
0.85
1.15
0.760751 923.0922
15.86
45
0.85
1.15
0.81997
994.9479
19.52
45
0.85
1.15
0.870087
1055.76
23.18
45
0.85
1.15
0.913875 1108.891
26.84
45
0.85
1.15
0.952967 1156.326
30.5
45
0.85
1.15
0.988416
34.16
45
0.85
1.15
1.020945 1238.809
37.82
45
0.85
1.15
1.051071 1275.364
41.48
45
0.85
1.15
1.07918
1309.472
45.14
45
0.85
1.15
1.10557
1341.493
1199.34
ASCE7-05
PROJECT:
JOB REF:
Building
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
ASCE7-05
DESIGN CODE
Internal pressure
Combined pressure
qz
Cp
qzGCp
qi
GCpi
qiGCpi
qzGCp+qiGCpi
qzGCp-qiGCpi
Leeward
All
1341.49
-0.5
0.85
-570.13
1341.49
0.18
241.47
-328.67
-811.60
Side walls
All
1341.49
-0.7
0.85
-798.19
1341.49
0.18
241.47
-556.72
-1039.66
Roof
45.14
1341.49
-0.9
0.85
-1026.24
1341.49
0.18
241.47
-784.77
-1267.71
697.36
0.8
0.85
474.21
1341.49
0.18
241.47
715.67
232.74
4.88
710.47
0.8
0.85
483.12
1341.49
0.18
241.47
724.59
241.65
8.54
833.66
0.8
0.85
566.89
1341.49
0.18
241.47
808.36
325.42
12.2
923.09
0.8
0.85
627.70
1341.49
0.18
241.47
869.17
386.23
15.86
994.95
0.8
0.85
676.56
1341.49
0.18
241.47
918.03
435.10
19.52
1055.76
0.8
0.85
717.92
1341.49
0.18
241.47
959.39
476.45
23.18
1108.89
0.8
0.85
754.05
1341.49
0.18
241.47
995.51
512.58
26.84
1156.33
0.8
0.85
786.30
1341.49
0.18
241.47
1027.77
544.83
30.5
1199.34
0.8
0.85
815.55
1341.49
0.18
241.47
1057.02
574.08
34.16
1238.81
0.8
0.85
842.39
1341.49
0.18
241.47
1083.86
600.92
37.82
1275.36
0.8
0.85
867.25
1341.49
0.18
241.47
1108.72
625.78
41.48
1309.47
0.8
0.85
890.44
1341.49
0.18
241.47
1131.91
648.97
45.14
1341.49
0.8
0.85
912.22
1341.49
0.18
241.47
1153.68
211774985.xls.ms_office
D2010
REVISION:
670.75
JOB REF:
Building
PROJECT:
D2010
REVISION:
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05
Windward face
Leeward face
Tributary
height
Building
width
Combined
design wind
force (kN)
4.88
4.88
56.1
715.67
195.93
-328.67
-89.98
285.91
8.54
3.66
56.1
724.59
148.78
-328.67
-67.48
216.26
12.2
3.66
56.1
808.36
165.98
-328.67
-67.48
233.46
15.86
3.66
56.1
869.17
178.46
-328.67
-67.48
245.95
19.52
3.66
56.1
918.03
188.50
-328.67
-67.48
255.98
23.18
3.66
56.1
959.39
196.99
-328.67
-67.48
264.47
26.84
3.66
56.1
995.51
204.41
-328.67
-67.48
271.89
30.5
3.66
56.1
1027.77
211.03
-328.67
-67.48
278.51
34.16
3.66
56.1
1057.02
217.03
-328.67
-67.48
284.52
37.82
3.66
56.1
1083.86
222.54
-328.67
-67.48
290.03
41.48
3.66
56.1
1108.72
227.65
-328.67
-67.48
295.13
45.14
3.66
56.1
1131.91
232.41
-328.67
-67.48
299.89
211774985.xls.ms_office
PROJECT:
211774985.xls.ms_office
JOB REF:
Building
D2010
REVISION:
PART OF STRUCTURE:
CALC. BY:
A.A
DRAWING REFERENCE:
CHECK. BY:
A.A
DESIGN CODE
ASCE7-05