HDPE Sheath, Power CablesA

This document provides information on WW HIPOW medium voltage power cables. Key details include: - The cables have aluminum conductors, XLPE insulation and HDPE sheathing. - They are used for underground residential power distribution from 11kV to 22kV. - Technical specifications include operating temperature ranges, minimum bending radii, voltage ratings and more. - Single core and three core configurations are available in various conductor sizes.

Uploaded by

kolombo1776
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
421 views6 pages

HDPE Sheath, Power CablesA

This document provides information on WW HIPOW medium voltage power cables. Key details include: - The cables have aluminum conductors, XLPE insulation and HDPE sheathing. - They are used for underground residential power distribution from 11kV to 22kV. - Technical specifications include operating temperature ranges, minimum bending radii, voltage ratings and more. - Single core and three core configurations are available in various conductor sizes.

Uploaded by

kolombo1776
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

WW HIPOW - Medium Voltage Power Cable

WW HIPOW MV POWER CABLE

WW HIPOW MV POWER CABLE

www.wwcables.com.au

World Wire Cables

WW HIPOW - Medium Voltage Power Cable


Copper conductors, XLPE insulated and HDPE sheathed
Applications:

Technical Data:

WW Medium voltage HDPE sheathed cables are mostly used as feeder electric

Voltage Ranges:

11kV ~ 33kV

cable for power distribution network where moisture penetration or heavy

Conductor operating temp:

-25 C ~ 90 C,

abrasion resistance is required. They are suitable for fix installation indoors,

Emergency conductor temp:

105 C,

outdoors, in underground and in dry/damp areas.

Short circuit temp:

Max. 250 C for 5 sec

Minimum ambient temp:

-25 C after installation and only when

cable is in a fixed position


Minimum bending radius:

25xcable O.D during installation


15xcable O.D after installation
2

Maximum pulling tension:

70N/mm x total cross-sectional area


of phase conductor

Three-Core
Note:
--The maximum conductor temperatures specified are based on the
properties of the insulation material but in practice may need to be derated to
take account of joints and terminations and environmental conditions.
--The emergency conductor temperatures are applicable for an average over
several years, of not more than four times in any 12 consecutive months.
-- One or two Single-Core cables are not allowed to be installed in iron pipes
due to the magnetic interference factor.
Single-Core

--When installed in tunnels, they should be fixed on brackets, and cannot


bear large pull or pressure.

Core colour:

Single-core:

Natural

Three-core:

Red, White and Blue

Configuration:
Sheath:

Phase conductor: plain annealed copper, class 2 compact stranded to reduce

Black - UV stabilise

the cable diameter and cost, complying with AS/NZS 1125


Phase core:

Availability:

triple extruded semi conductive conductor screen, crosslinked polyethylene (XLPE) insulation and semi conductive

Halogen-free sheath and large size can be manufactured to customer order,

insulation screen to AS/NZS 3808.

further detail are available on request.

Metallic screen: copper wires screen provides high conductivity for faulty

Standards:

current as earth wires. (Plain annealed copper wire has a


minimum diameter of 0.85 mm).Water-swellable tape

International - IEC 60228, IEC 60502, IEC 60853,

collectively applied over the metallic screen.


Interstitial filler:

for three-core cable only, non-hydroscopic material.

Bedding:

Flame retardant 90 C heavy duty polyvinyl chloride (PVC).

Sheath:

High density polyethylene (HDPE)

IEC 60949, IEC 60724, IEC 60986.

Australian/New Zealand - AS/NZS 1125, AS/NZS 3808,


AS/NZS 1429.1,

12

www.wwcables.com.au

World Wire Cables

WW HIPOW - Medium Voltage Power Cable


Copper conductors, XLPE insulated and HDPE sheathed
Physical and Electrical Data - Single Core
Rated

Standard

Nominal.

Core

Overall

Approx.

Mutual

Product

Area

Dia.

Dia.

Weight

A.C resist
o
@90 C,50Hz,

Operating

Voltage

Inductance

Capacitance

Conductor

Screen

kV

Code

mm2

mm

mm

kg/m

/km

mH/km

F/km

kA/sec

kA/sec

11

22

33

Fault Current Rating

MV11C5X1C35HP

35

17.02

26.27

0.94

0.668

0.486

0.217

5.0

5.0

MV11C7X1C50HP

50

18.32

27.67

1.22

0.467

0.460

0.244

7.2

7.2

MV11C10X1C70HP

70

19.78

29.23

1.65

0.332

0.441

0.275

10

10.1

MV11C10X1C95HP

95

21.34

30.90

1.97

0.247

0.421

0.308

13.6

10.1

MV11C10X1C120HP

120

22.70

32.36

2.29

0.196

0.399

0.336

17.2

10.1

MV11C10X1C150HP

150

24.16

33.92

2.62

0.157

0.386

0.366

21.5

10.1

MV11C10X1C185HP

185

25.69

35.55

2.99

0.128

0.374

0.397

26.5

10.1

MV11C10X1C240HP

240

27.82

37.84

3.64

0.099

0.358

0.441

34.3

10.1

MV11C10X1C300HP

300

29.88

40.04

4.35

0.080

0.347

0.482

42.9

10.1

MV11C10X1C400HP

400

32.91

43.28

5.34

0.062

0.338

0.544

57.2

10.1

MV22C5X1C35HP

35

21.43

30.99

1.12

0.668

0.515

0.173

5.0

5.0

MV22C7X1C50HP

50

22.73

32.39

1.32

0.467

0.488

0.193

7.2

7.2

MV22C10X1C70HP

70

24.19

33.95

1.80

0.332

0.468

0.215

10

10.1

MV22C10X1C95HP

95

25.75

35.62

2.20

0.247

0.446

0.238

13.6

10.1

MV22C10X1C120HP

120

27.11

37.08

2.49

0.196

0.424

0.258

17.2

10.1

MV22C10X1C150HP

150

28.57

38.64

2.78

0.157

0.410

0.279

21.5

10.1

MV22C10X1C185HP

185

30.10

40.27

3.28

0.128

0.397

0.302

26.5

10.1

MV22C10X1C240HP

240

32.23

42.55

3.88

0.099

0.385

0.332

34.3

10.1

MV22C10X1C300HP

300

34.29

44.76

4.67

0.080

0.372

0.362

42.9

10.1

MV22C10X1C400HP

400

37.32

48.00

5.66

0.061

0.357

0.405

57.2

10.1

MV33C7X1C50HP

50

27.98

37.15

1.69

0.467

0.518

0.160

7.2

7.2

MV33C10X1C70HP

70

29.44

38.71

2.18

0.332

0.495

0.177

10

10.1

MV33C10X1C95HP

95

31.00

40.38

2.47

0.247

0.473

0.194

13.6

10.1

MV33C10X1C120HP

120

32.36

41.84

2.88

0.195

0.455

0.210

17.2

10.1

MV33C10X1C150HP

150

33.82

43.40

3.18

0.157

0.439

0.226

21.5

10.1

MV33C10X1C185HP

185

35.35

45.03

3.67

0.127

0.425

0.242

26.5

10.1

MV33C10X1C240HP

240

37.48

47.32

4.36

0.098

0.407

0.265

34.3

10.1

MV33C10X1C300HP

300

39.54

49.52

5.08

0.080

0.398

0.287

42.9

10.1

MV33C10X1C400HP

400

42.57

52.76

6.16

0.061

0.380

0.320

57.2

10.1

13

www.wwcables.com.au

World Wire Cables

WW HIPOW - Medium Voltage Power Cable


Copper conductors, XLPE insulated and HDPE sheathed
Physical and Electrical Data - Three Core
Rated

Standard

Nominal.

Core

Overall

Approx.

Mutual

Product

Area

Dia.

Dia.

Weight

A.C resist
o
@90 C,50Hz,

Operating

Voltage

Inductance

Capacitance

Conductor

Screen

kV

Code

mm2

mm

mm

kg/m

/km

mH/km

F/km

kA/sec

kA/sec

MV11C5X3C35HP

35

17.02

49.10

2.42

0.668

0.486

0.217

5.0

5.0

MV11C7X3C50HP

50

18.32

52.10

3.01

0.467

0.460

0.244

7.2

7.2

MV11C10X3C70HP

70

19.78

55.47

4.04

0.332

0.441

0.275

10

10.1

MV11C10X3C95HP

95

21.34

59.06

5.01

0.247

0.421

0.308

13.6

10.1

MV11C10X3C120HP

120

22.70

62.20

6.06

0.196

0.399

0.336

17.2

10.1

MV11C10X3C150HP

150

24.16

65.56

7.01

0.157

0.386

0.366

21.5

10.1

MV11C10X3C185HP

185

25.69

69.08

8.38

0.128

0.374

0.397

26.5

10.1

MV11C10X3C240HP

240

27.82

74.00

10.40

0.099

0.358

0.441

34.3

10.1

MV11C10X3C300HP

300

29.88

78.75

12.58

0.080

0.347

0.482

42.9

10.1

MV11C10X3C400HP

400

32.91

85.72

15.75

0.062

0.338

0.544

57.2

10.1

MV22C5X3C35HP

35

21.43

59.26

3.04

0.668

0.515

0.173

5.0

5.0

MV22C7X3C50HP

50

22.73

62.26

3.73

0.467

0.488

0.193

7.2

7.2

MV22C10X3C70HP

70

24.19

65.63

4.85

0.332

0.468

0.215

10

10.1

MV22C10X3C95HP

95

25.75

69.22

5.94

0.247

0.446

0.238

13.6

10.1

MV22C10X3C120HP

120

27.11

72.36

6.93

0.196

0.424

0.258

17.2

10.1

MV22C10X3C150HP

150

28.57

75.73

8.02

0.157

0.410

0.279

21.5

10.1

MV22C10X3C185HP

185

30.10

79.25

9.31

0.128

0.397

0.302

26.5

10.1

MV22C10X3C240HP

240

32.23

84.16

11.50

0.099

0.385

0.332

34.3

10.1

MV22C10X3C300HP

300

34.29

88.92

13.86

0.080

0.372

0.362

42.9

10.1

MV22C10X3C400HP

400

37.32

95.89

17.14

0.061

0.357

0.405

57.2

10.1

MV33C7X3C50HP

50

27.98

74.50

5.1

0.467

0.518

0.160

7.2

7.2

MV33C10X3C70HP

70

29.44

77.94

6.2

0.332

0.495

0.177

10

10.1

MV33C10X3C95HP

95

31.00

81.60

7.4

0.247

0.473

0.194

13.6

10.1

MV33C10X3C120HP

120

32.36

84.80

8.4

0.195

0.455

0.210

17.2

10.1

MV33C10X3C150HP

150

33.82

88.23

9.6

0.157

0.439

0.226

21.5

10.1

MV33C10X3C185HP

185

35.35

91.82

11.0

0.127

0.425

0.242

26.5

10.1

MV33C10X3C240HP

240

37.48

96.83

13.2

0.098

0.407

0.265

34.3

10.1

MV33C10X3C300HP

300

39.54

101.68

15.6

0.080

0.398

0.287

42.9

10.1

MV33C10X3C400HP

400

42.57

108.79

19.1

0.061

0.380

0.320

57.2

10.1

11

22

33

14

Fault Current Rating

www.wwcables.com.au

World Wire Cables

WW HIPOW - Medium Voltage Power Cable

WW HIPOW MV POWER CABLE

www.wwcables.com.au

World Wire Cables

WW HIPOW - Medium Voltage Power Cable


Aluminum conductors, XLPE insulated and HDPE sheathed
Applications:

Technical Data:

WW Medium Voltage HDPE sheathed aluminium conductors cables are mostly


used as feeder electric cable for underground residential power distribution
network where moisture penetration or heavy abrasion resistance is required.
They are suitable for fix installation in underground and in dry/damp areas or in
concrete group pipes.

Voltage Ranges:
Conductor operating temp:
Emergency conductor temp:
Short circuit temp:
Minimum ambient temp:
Minimum bending radius:
Maximum pulling tension:

11kV ~ 22kV
o
o
-25 C ~ 90 C,
o
105 C,
o
Max. 250 C for 5 sec
o
-25 C after installation and only when
cable is in a fixed position
25xcable O.D during installation
15xcable O.D after installation
2
50N/mm x total cross-sectional area
of phase conductor

Note:
Three-Core

--The maximum conductor temperatures specified are based on the


properties of the insulation material but in practice may need to be derated to
take account of joints and terminations and environmental conditions.
--The emergency conductor temperatures are applicable for an average over
several years, of not more than four times in any 12 consecutive months.
--When installed in tunnels, they should be fixed on brackets, and cannot
bear large pull or pressure.

Configuration:
Phase conductor: plain aluminium, class 2 compact stranded to reduce the
Core colour:
Sheath:

cable diameter and cost, complying with AS/NZS 1125.


Phase core:

triple extruded semi conductive conductor screen, cross-

Red, White and Blue


Black - UV stabilise

linked polyethylene (XLPE) insulation and semi conductive


insulation screen to AS/NZS 3808.

Availability:

Metallic screen: copper wires screen provides high conductivity for faulty

Halogen-free sheath and large size can be manufactured to customer order,


further detail are available on request.

current as earth wires. (Plain annealed copper wire has a


minimum diameter of 0.85 mm).Water-swellable tape

Standards:

collectively applied over the metallic screen.


Interstitial filler:

for three-core cable only, non-hydroscopic material.

Bedding:

Flame retardant 90oC polyvinyl chloride (PVC).

Sheath:

High density polyethylene (HDPE)

International - IEC 60228, IEC 60502, IEC 60853,


IEC 60949, IEC 60724, IEC 60986.
Australian/New Zealand - AS/NZS 1125, AS/NZS 3808,
AS/NZS 1429.1, AD/NZS 4026

Physical and Electrical Data - Three Core


Rated

Standard

Nominal.

Core

Overall

Approx.

Mutual

Product

Area

Dia.

Dia.

Weight

A.C resist
@90oC,50Hz,

Operating

Voltage

Inductance

Capacitance

Conductor

Screen

kV

Code

mm2

mm

mm

kg/m

/km

mH/km

F/km

kA/sec

kA/sec

35

17.02

49.10

1.90

1.106

0.393

0.217

3.3

3.3

MV11A5X3C35HP

11

22

Fault Current Rating

MV11A10X3C95HP

95

21.34

59.06

3.20

0.408

0.336

0.308

9.0

9.0

MV11A10X3C185HP

185

25.69

69.08

4.70

0.213

0.303

0.397

17.5

10.1

MV11A10X3C240HP

240

27.82

74.00

5.70

0.162

0.293

0.441

22.7

10.1

MV11A10X3C300HP

300

29.88

78.75

6.50

0.131

0.282

0.482

28.4

10.1

MV22A5X3C35HP

35

21.43

59.26

2.60

1.106

0.435

0.173

3.3

3.3

MV22A10X3C95HP

95

25.75

69.22

4.00

0.408

0.371

0.238

9.0

9.0

MV22A10X3C185HP

185

30.10

79.25

5.13

0.213

0.332

0.302

17.5

10.1

MV22A10X3C240HP

240

32.23

84.16

6.70

0.162

0.318

0.332

22.7

10.1

15

www.wwcables.com.au

World Wire Cables